Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.719
Filtrar
1.
Anticancer Res ; 44(5): 2021-2030, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38677765

RESUMO

BACKGROUND/AIM: In the context of surgical de-escalation in early breast cancer (EBC), this study aimed to evaluate the contrast enhancement ultrasound (CEUS) sentinel lymph node (SLN) procedure as a non-invasive axillary staging procedure in EBC in comparison with standard SLN biopsy (SLNB). PATIENTS AND METHODS: A subanalysis of the AX-CES study, a prospective single-arm, monocentric phase 3 study was performed (EudraCT: 2020-000393-20). The study included patients with EBC undergoing upfront surgery and SLN resection, with no prior history of locoregional treatment, and weighing between 40-85 kg. All patients underwent the CEUS SLN procedure as a non-invasive axillary staging procedure, with CEUS SLN accumulation marked using blue dye. After the CEUS SLN procedure, all patients underwent the standard mapping procedure. Data on success rate, systemic reactions, mean procedure time, mean surgical procedure, mean procedure without axillary staging, CEUS SLN appearance (normal/pathological), SLN number, and concordance with standard mapping procedure were collected. RESULTS: After the CEUS SLN procedure, 29 LNs among 16 patients were identified and marked. In all cases, CEUS SLN revealed at least one LN enhancement. Six (37.50%) LNs were defined as pathological after the CEUS SLN procedure. Definitive staining of CEUS SLN pathology revealed metastatic involvement in four (66.67%) of the cases. Two SLNs were identified during the CEUS SLN procedure; however, owing to the low disease burden, no change in the surgical plan was reported. CONCLUSION: The CEUS SLN procedure shows promise as a technique for non-invasive assessment of the axilla, potentially enabling safe axillary de-escalation in EBC by estimating the axillary disease burden.


Assuntos
Axila , Neoplasias da Mama , Meios de Contraste , Estadiamento de Neoplasias , Biópsia de Linfonodo Sentinela , Hexafluoreto de Enxofre , Humanos , Neoplasias da Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Feminino , Meios de Contraste/administração & dosagem , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Biópsia de Linfonodo Sentinela/métodos , Hexafluoreto de Enxofre/administração & dosagem , Ultrassonografia/métodos , Microbolhas , Metástase Linfática/diagnóstico por imagem , Linfonodo Sentinela/patologia , Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/cirurgia , Adulto
2.
Ultrason Imaging ; 46(3): 178-185, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38622911

RESUMO

To evaluate the inter-observer variability and the intra-observer repeatability of pulmonary transit time (PTT) measurement using contrast-enhanced ultrasound (CEUS) in healthy rabbits, and assess the effects of dilution concentration of ultrasound contrast agents (UCAs) on PTT. Thirteen healthy rabbits were selected, and five concentrations UCAs of 1:200, 1:100, 1:50, 1:10, and 1:1 were injected into the right ear vein. Five digital loops were obtained from the apical 4-chamber view. Four sonographers obtained PTT by plotting the TIC of right atrium (RA) and left atrium (LA) at two time points (T1 and T2). The frame counts of the first appearance of UCAs in RA and LA had excellent inter-observer agreement, with intra-class correlations (ICC) of 0.996, 0.988, respectively. The agreement of PTT among four observers was all good at five different concentrations, with an ICC of 0.758-0.873. The reproducibility of PTT obtained by four observers at T1 and T2 was performed well, with ICC of 0.888-0.961. The median inter-observer variability across 13 rabbits was 6.5% and the median variability within 14 days for 4 observers was 1.9%, 1.7%, 2.2%, 1.9%, respectively; The PTT of 13 healthy rabbits is 1.01 ± 0.18 second. The difference of PTT between five concentrations is statistically significant. The PTT obtained by a concentration of 1:200 and 1:100 were higher than that of 1:1, while there were no significantly differences in PTT of a concentration of 1:1, 1:10, and 1:50. PTT measured by CEUS in rabbits is feasible, with excellent inter-observer and intra-observer reliability and reproducibility, and dilution concentration of UCAs influences PTT results.


Assuntos
Meios de Contraste , Estudos de Viabilidade , Variações Dependentes do Observador , Ultrassonografia , Animais , Coelhos , Reprodutibilidade dos Testes , Ultrassonografia/métodos , Hexafluoreto de Enxofre/farmacocinética , Circulação Pulmonar/fisiologia
3.
Ultrasound Med Biol ; 50(6): 954-960, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38575414

RESUMO

The purpose of this study was to retrospectively analyze the characteristics of contrast-enhanced ultrasound (CEUS) images and quantitative parameters of time-intensity curves (TICs) in children's peripheral neuroblastic tumors (pNTs). By comparing the imaging features and quantitative parameters of the TICs of neuroblastoma (NB) and ganglioneuroblastoma (GNB) patients, we attempted to identify the distinguishing points between NB and GNB. A total of 35 patients confirmed to have pNTs by pathologic examination were included in this study. Each child underwent CEUS with complete imaging data (including still images and at least 3 min of video files). Twenty-four patients were confirmed to have NB, and 11 were considered to have GNB according to differentiation. The CEUS image features and quantitative parameters of the TICs of all lesions were analyzed to determine whether there were CEUS-related differences between the two types of pNT. There was a significant difference in the enhancement patterns of the CEUS features (χ2 = 5.303, p < 0.05), with more "peripheral-central" enhancement in the NB group and more "central-peripheral" enhancement in the GNB group. In the TIC, the rise time and time to peak were significantly different (p < 0.05). The receiver operating characteristic curve showed that the probability of ganglion cell NB increased significantly after RT > 15.29, with a sensitivity of 0.636 and a specificity of 0.958. When the peak time was greater than 16.155, the probability of NB increased significantly, with a sensitivity of 0.636 and a specificity of 0.958. The CEUS features of NB and GNB patients are very similar, and it is difficult to distinguish them. Rise time and time to peak may be useful in identifying GNB and NB, but the sample size of this study was small, and the investigation was only preliminary; a larger sample size is needed to support these conclusions.


Assuntos
Meios de Contraste , Aumento da Imagem , Neuroblastoma , Ultrassonografia , Humanos , Masculino , Neuroblastoma/diagnóstico por imagem , Feminino , Ultrassonografia/métodos , Pré-Escolar , Lactente , Estudos Retrospectivos , Criança , Aumento da Imagem/métodos , Ganglioneuroblastoma/diagnóstico por imagem , Sensibilidade e Especificidade , Reprodutibilidade dos Testes , Diagnóstico Diferencial , Hexafluoreto de Enxofre
4.
Eur J Ophthalmol ; 34(3): NP34-NP38, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38233368

RESUMO

PURPOSE: To report three cases of postoperative opacification of sutureless scleral-fixed hydrophilic intraocular lens (FIL SSF IOL, Soleko, Italy) after gas tamponade. Two cases occurred after pars plana vitrectomy and one case after Descemet membrane endothelial keratoplasty. CASE REPORT: Two diabetic patients underwent a FIL SSF IOL implantation after posterior capsular rupture during cataract surgery. Rhegmatogenous retinal detachment (RRD) was observed in one patient during the initial surgery. A second patient developed a RRD five months after surgery. Both RRDs were treated with pars plana vitrectomy and perfluoroethane (C2F6) gas tamponade. A few days after the surgery, C2F6 was observed in the anterior chamber of both patients. Two months after gas tamponade, opacification of the anterior surface of the IOL was observed. The third patient was a 74-year-old woman, who underwent a combined Descemet membrane endothelial keratoplasty (DMEK) and FIL SSF IOL implantation. Two rebubblings with sulfur hexafluoride (SF6) retreatments were required due to corneal graft detachment. One month later, an opacification of the anterior surface of the IOL was observed. Explantation with implantation of iris-claw IOL was decided, which resulted in an improvement of BVCA. Analysis of the IOL showed a positive Von Kossa staining, indicating calcification of the IOL. We performed a review of all the cases of FIL SSF IOL implantation in our centers. The overall rate of FIL SSF IOL opacification was 2.1% (3/140). Amongst patients treated with gas tamponade, the rate of opacification was 27.3% (3/11). Although FIL SSF IOL implantation appears to be an effective option for the treatment of aphakia, caution should be exercised regarding the risk of opacification following gas tamponade, especially since these patients are at risk of retinal detachment.


Assuntos
Tamponamento Interno , Lentes Intraoculares , Vitrectomia , Humanos , Feminino , Idoso , Lentes Intraoculares/efeitos adversos , Masculino , Complicações Pós-Operatórias , Fluorocarbonos/administração & dosagem , Falha de Prótese , Implante de Lente Intraocular , Acuidade Visual , Pessoa de Meia-Idade , Hexafluoreto de Enxofre/administração & dosagem
5.
Retina ; 44(5): 791-798, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38236936

RESUMO

PURPOSE: To compare SF 6 relative with C 2 F 6 in the anatomical and functional outcomes following pars plana vitrectomy for uncomplicated primary pseudophakic rhegmatogenous retinal detachment with inferior causative breaks. METHODS: This is a retrospective, comparative study on eyes with pseudophakic rhegmatogenous retinal detachment with inferior causative breaks that had small-gauge pars plana vitrectomy repair using SF 6 and C 2 F 6 tamponade between 2011 and 2020 at a tertiary centre in the United Kingdom. Primary outcome was single surgery anatomical success, and the secondary outcome was best-corrected visual acuity. Propensity score matching, using preoperative findings as covariates to account for relevant confounders, was performed. RESULTS: From 162 pseudophakic rhegmatogenous retinal detachment eyes with inferior causative breaks, the median (interquartile range) follow-up was 82 (52-182) days. The single surgery anatomical success was 156 (96.3%) overall: 47 of 47 (100.0%) and 109 of 115 (94.8%) in the SF 6 and C 2 F 6 groups, respectively ( P = 0.182). Relative to the SF 6 group, the C 2 F 6 group had a higher mean number of tears (SF 6 : 3.1[2.0], C 2 F 6 : 4.5[2.7], P = 0.002) and greater retinal detachment extent (SF 6 : 5.3[2.9], C 2 F 6 : 6.2[2.6] clock hours, P = 0.025). Following propensity score matching analysis, 80 eyes were matched with 40 in each group to homogenize preoperative factors. No significant difference was found in single surgery anatomical success and best-corrected visual acuity between the groups following propensity score matching. CONCLUSION: Primary pars plana vitrectomy with gas tamponade leads to a high single surgery anatomical success rate in uncomplicated pseudophakic rhegmatogenous retinal detachment with inferior causative breaks with no additional benefit associated with long-acting tamponade when comparing C 2 F 6 with SF 6 .


Assuntos
Tamponamento Interno , Fluorocarbonos , Pseudofacia , Descolamento Retiniano , Hexafluoreto de Enxofre , Acuidade Visual , Vitrectomia , Humanos , Descolamento Retiniano/cirurgia , Descolamento Retiniano/etiologia , Vitrectomia/métodos , Estudos Retrospectivos , Feminino , Masculino , Acuidade Visual/fisiologia , Pseudofacia/fisiopatologia , Pseudofacia/complicações , Tamponamento Interno/métodos , Idoso , Hexafluoreto de Enxofre/administração & dosagem , Pessoa de Meia-Idade , Fluorocarbonos/administração & dosagem , Perfurações Retinianas/cirurgia , Perfurações Retinianas/etiologia , Perfurações Retinianas/diagnóstico , Seguimentos , Resultado do Tratamento
6.
J Pharm Pract ; 37(2): 509-512, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36803045

RESUMO

Ultrasound enhancing agents (UEAs) are medications that enable clear visualization of ultrasound images. While large studies have demonstrated the safety of these agents, case reports of life-threatening reactions temporally associated with their use have been published and reported to the Food and Drug Administration. Current literature describes the most serious adverse reactions due to UEAs to be allergic in nature; however, embolic phenomena may play a role as well. Here, we report a case of unexplained cardiac arrest following the administration of sulfur hexafluoride (Lumason®) in an adult inpatient undergoing echocardiography where resuscitative efforts were ultimately unsuccessful, and review possible mechanisms of cardiac arrest based on prior published literature.


Assuntos
Parada Cardíaca , Hexafluoreto de Enxofre , Adulto , Humanos , Hexafluoreto de Enxofre/efeitos adversos , Meios de Contraste/efeitos adversos , Ultrassonografia/métodos , Administração Intravenosa , Parada Cardíaca/induzido quimicamente
7.
Eur Radiol ; 34(1): 622-631, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37566263

RESUMO

OBJECTIVE: To compare contrast-enhanced ultrasound (CEUS) with microbubbles containing sulfur hexafluoride (SHF) and perfluorobutane (PFB) for the detection of colorectal liver metastasis (CRLM). METHODS: In this prospective study, conducted from September to November 2021, patients with colorectal cancer were consecutively recruited and underwent same-day ultrasound, SHF-CEUS, and PFB-CEUS. The reference standard was contrast-enhanced MRI and follow-up imaging. The size, depth, echogenicity, and calcification of each focal liver lesion were recorded. The number and conspicuity of CRLMs, based on washout appearance during the late phase (LP) (> 120 s)/Kupffer phase (KP), were evaluated offsite by two blinded readers. RESULTS: Overall, 230 lesions (CRLMs, n = 219; benign lesions, n = 11) in 78 patients were evaluated. Lesion conspicuity (p = 0.344) and accuracy in the detection of CRLM were comparable for SHF- and PFB-CEUS (0.877 for SHF vs. 0.770 for PFB, p = 0.087). More CRLMs ≥ 10 mm were identified by LP contrast washout in SHF-CEUS than in KP PFB-CEUS (p < 0.001). More CRLMs < 10 mm were identified by KP washout in PFB-CEUS than in LP SHF-CEUS (p < 0.001). Conspicuity was better on PFB-CEUS than on SHF-CEUS (p = 0.027). In hyperechoic lesions, lesions located deeper than 80 mm, and calcified lesions, CRLM conspicuity on PFB-CEUS was inferior to that on SHF-CEUS (p < 0.05). CONCLUSIONS: The overall accuracy of detection and conspicuity of washout in CRLMs were comparable between SHF and PFB-CEUS. PFB-CEUS has the advantage of identifying washout in small CRLMs. However, larger, hyperechogenic, deep-seated, or calcified lesions were better identified using SHF-CEUS. CLINICAL RELEVANCE STATEMENT: Accuracy of detection and conspicuity of washout in CRLMs were comparable between SHF- and PFB-CEUS. PFB-CEUS has the advantage in detecting small CRLMs, whereas SHF-CEUS is better for detecting larger, hyperechogenic, deep-seated, or calcified lesions. KEY POINTS: Contrast-enhanced ultrasound with sulfur hexafluoride in the late phase and perfluorobutane microbubbles in the Kupffer phase were comparable in terms of accuracy in the detection and conspicuity of colorectal liver metastases. Small colorectal liver metastases (< 10 mm) were more often identified in the Kupffer phase contrast-enhanced ultrasound imaging when using perfluorobutane microbubbles. Larger, hyperechogenic, deep-seated, or calcified lesions were better identified in the late phase contrast-enhanced ultrasound imaging (> 120 s) when using sulfur hexafluoride microbubbles.


Assuntos
Neoplasias Colorretais , Fluorocarbonos , Neoplasias Hepáticas , Humanos , Hexafluoreto de Enxofre , Meios de Contraste , Estudos Prospectivos , Microbolhas , Neoplasias Hepáticas/patologia , Ultrassonografia/métodos
8.
Chest ; 165(2): 396-404, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37716474

RESUMO

BACKGROUND: The early life origins of chronic pulmonary diseases are thought to arise in peripheral small airways. Predictors of ventilation inhomogeneity, a proxy of peripheral airway function, are understudied in schoolchildren. RESEARCH QUESTION: Is the double-tracer gas single-breath washout (DTG-SBW) measurement feasible in a pediatric field study setting? What are the predictors of the DTG-SBW-derived ventilation inhomogeneity estimate in unselected schoolchildren? STUDY DESIGN AND METHODS: In this prospective cross-sectional field study, a mobile lung function testing unit visited participating schools in Switzerland. We applied DTG-SBW, fraction of exhaled nitric oxide (Feno), and spirometry measurements. The DTG-SBW is based on tidal inhalation of helium and sulfur-hexafluoride, and the phase III slope (SIIIHe-SF6) is derived. We assessed feasibility, repeatability, and associations of SIIIHe-SF6 with the potential predictors of anthropometrics, presence of wheeze (ie, parental report of one or more episode of wheeze in the prior year), Feno, FEV1, and FEV1/FVC. RESULTS: In 1,782 children, 5,223 DTG-SBW trials were obtained. The DTG-SBW was acceptable in 1,449 children (81.3%); the coefficient of variation was 39.8%. SIIIHe-SF6 was independently but weakly positively associated with age and BMI. In 276 children (21.2%), wheeze was reported. SIIIHe-SF6 was higher by 0.049 g.mol.L-1 in children with wheeze compared with those without and remained associated with wheeze after adjusting for age and BMI in a multivariable linear regression model. SIIIHe-SF6 was not associated with Feno, FEV1, and FEV1/FVC. INTERPRETATION: The DTG-SBW is feasible in a pediatric field study setting. On the population level, age, body composition, and wheeze are independent predictors of peripheral airway function in unselected schoolchildren. The variation of the DTG-SBW possibly constrains its current applicability on the individual level. TRIAL REGISTRATION: ClinicalTrials.gov; No.: NCT03659838; URL: www. CLINICALTRIALS: gov.


Assuntos
Gases , Respiração , Humanos , Criança , Estudos Prospectivos , Estudos Transversais , Testes Respiratórios , Hexafluoreto de Enxofre
9.
Ann Work Expo Health ; 68(1): 86-96, 2024 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-38037180

RESUMO

Sulfur hexafluoride (SF6) is the reference tracer gas in many international standards for characterizing respiratory protective devices (RPD), fume cupboards, building ventilations, and other installations. However, due to its significant impact on global warming, its use is becoming increasingly restrictive. Krypton 84 (Kr) was chosen to be a possible replacement based on theoretical and practical criteria for the properties that a substitute gas should possess. While compliance with these criteria is generally sufficient to guarantee the reliability of the choice, it is essential in the case of widespread use such as a standard to validate experimentally that this tracer has the same behavior as SF6. In this regard, numerous tests have been carried out to characterize the face leakage of RPD and the rupture of containment of fume cupboards performance tests under different operating conditions. The results obtained are identical with both tracers and lead us to propose the use of Kr as a new reference gas in standards for which SF6 was used.


Assuntos
Exposição Ocupacional , Humanos , Exposição Ocupacional/prevenção & controle , Criptônio , Reprodutibilidade dos Testes , Gases/análise , Hexafluoreto de Enxofre/análise , Padrões de Referência
11.
J Fr Ophtalmol ; 47(2): 103979, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37858497

RESUMO

PURPOSE: To compare the efficacy of three different gases for intraocular tamponade: 100% air, 10% perfluoropropane (C3F8), and 10% sulfur hexafluoride (SF6), in Descemet's membrane endothelial keratoplasty (DMEK). MATERIALS AND METHODS: The medical records of 138 patients who underwent DMEK were reviewed retrospectively, with the primary outcome being the rebubbling rate in the first week following surgery. Other clinical outcomes, such as best-corrected visual acuity (BCVA), central corneal thickness (CCT), incidence of rebubbling after the first week, endothelial cell density (ECD), graft detachment, graft failure, pupillary block, and intraocular pressure (IOP) changes were also analyzed. RESULTS: Of the 138 patients, 57 were in group 1 (treated with air), 44 in group 2 (treated with 10% C3F8), and 37 in group 3 (treated with 10% SF6). Group 3 showed significantly lower rates of graft detachment and rebubbling compared to groups 1 and 2 (P<0.001). However, there was no significant difference in postoperative BCVA among the groups. At one year, the mean endothelial cell loss was 32% in group 1, 30% in group 2, and 33% in group 3 (P=0.715). One patient in group 1 experienced pupillary block and increased IOP, while there were no such occurrences in the other groups. There was no difference between the groups in terms of graft failure. CONCLUSION: The use of 10% SF6 in DMEK surgery may be a good option due to its efficacy in preventing graft detachment, low rebubbling rate, and potential for minimizing complications.


Assuntos
Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Distrofia Endotelial de Fuchs , Humanos , Lâmina Limitante Posterior/cirurgia , Gases , Estudos Retrospectivos , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/efeitos adversos , Acuidade Visual , Tamponamento Interno , Câmara Anterior/cirurgia , Distrofia Endotelial de Fuchs/cirurgia , Hexafluoreto de Enxofre , Endotélio Corneano/transplante
12.
Ultrasound Med Biol ; 50(2): 191-197, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37940461

RESUMO

OBJECTIVE: The aim of the work described here was to investigate the feasibility and diagnostic value of using contrast-enhanced ultrasound (CEUS) galactography with SonoVue in patients with pathologic nipple discharge (PND). METHODS: Twenty-eight patients who underwent breast surgery for PND from May 2019 to August 2021 were included. Routine ultrasound, ductoscopy and CEUS galactography were performed successively. Lesions were diagnosed and localized. The sensitivity, specificity and pre-operative localization value of each examination method were evaluated on post-operative pathology. RESULTS: CEUS galactography was successfully conducted in all 28 patients and revealed negative ductal ectasia, filling stop and filling defect. Ductoscopy revealed positive nodules in 21 cases and negative nodules in 7 cases. A total of 18 nodules were found by routine ultrasound, and the relationship between all nodules and the discharge duct was confirmed after CEUS galactography. Compared with the other two methods, CEUS galactography had higher sensitivity, positive predictive value and negative predictive value (100%, 81.82% and 100%, respectively), while it has the same specificity as routine ultrasound (both 60%). The pre-operative location of the nipple duct was consistent with the intra-operative findings in 28 patients after CEUS galactography. CONCLUSION: The ultrasound contrast agent SonoVue can be used for CEUS galactography in patients with PND. CEUS galactography can improve the detection of ductal nodules and locate the nipple discharge duct pre-operatively. As the technique does not emit radiation and SonoVue is easily metabolized and safe, CEUS galactography is better than conventional imaging for PND patients.


Assuntos
Neoplasias da Mama , Derrame Papilar , Humanos , Feminino , Relevância Clínica , Mamografia/métodos , Derrame Papilar/diagnóstico por imagem , Hexafluoreto de Enxofre , Mamilos/diagnóstico por imagem , Mamilos/metabolismo , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Neoplasias da Mama/metabolismo
13.
Ultrasound Med Biol ; 50(3): 414-424, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38155069

RESUMO

OBJECTIVE: This study was aimed at developing and comparing prediction models based on Sonovue and Sonazoid contrast-enhanced ultrasound (CEUS) in predicting pathologic grade and microvascular invasion (MVI) of hepatocellular carcinoma (HCC). Also investigated was whether Kupffer phase images have additional predictive value for the above pathologic features. METHODS: Ninety patients diagnosed with primary HCC who had undergone curative hepatectomy were prospectively enrolled. All patients underwent conventional ultrasound (CUS), Sonovue-CEUS and Sonazoid-CEUS examinations pre-operatively. Clinical, radiologic and pathologic features including pathologic grade, MVI and CD68 expression were collected. We developed prediction models comprising clinical, CUS and CEUS (Sonovue and Sonazoid, respectively) features for pathologic grade and MVI with both the logistic regression and machine learning (ML) methods. RESULTS: Forty-one patients (45.6%) had poorly differentiated HCC (p-HCC) and 37 (41.1%) were MVI positive. For pathologic grade, the logistic model based on Sonazoid-CEUS had significantly better performance than that based on Sonovue-CEUS (area under the curve [AUC], 0.929 vs. 0.848, p = 0.035), whereas for MVI, these two models had similar accuracy (AUC, 0.810 vs. 0.786, p = 0.068). Meanwhile, we found that well-differentiated HCC tended to have a higher enhancement ratio in 6-12 min during the Kupffer phase of Sonazoid-CEUS, as well as higher CD68 expression compared with p-HCC. In addition, all of these models can effectively predict the risk of recurrence (p < 0.05). CONCLUSION: Sonovue-CEUS and Sonazoid-CEUS were comparably excellent in predicting MVI, while Sonazoid-CEUS was superior to Sonovue-CEUS in predicting pathologic grade because of the Kupffer phase. The enhancement ratio in the Kupffer phase has additional predictive value for pathologic grade prediction.


Assuntos
Carcinoma Hepatocelular , Compostos Férricos , Ferro , Neoplasias Hepáticas , Óxidos , Fosfolipídeos , Hexafluoreto de Enxofre , Humanos , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/patologia , Meios de Contraste , Estudos Retrospectivos
14.
Medicina (Kaunas) ; 59(12)2023 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-38138180

RESUMO

Background and Objectives: This review paper highlights the key alternatives to the blue dye/radioisotope method of sentinel lymph node biopsy (SLNB). It analyses the research available on these alternative methods and their outcomes compared to the traditional techniques. Materials and Methods: This review focused on fifteen articles, of which five used indocyanine green (ICG) as a tracer, four used magnetic tracers, one used one-step nucleic acid amplification (OSNA) and Metasin (quantitative reverse transcriptase-polymerase chain reaction), one used the photosensitiser talaporfin sodium, one used sulphur hexafluoride gas microbubbles, one used CT-guided lymphography and two focused on general SLNB technique reviews. Results: Of the 15 papers analysed, the sentinel node detection rates were 69-100% for indocyanine green, 91.67-100% for magnetic tracers, 81% for talaporfin sodium, 9.3-55.2% for sulphur hexafluoride gas microbubbles, 90.5% for CTLG and 82.7-100% for one-step nucleic acid amplification. Conclusions: Indocyanine green fluorescence (ICG) and magnetic tracers have been proven non-inferior to traditional blue dye and isotope regarding SLNB localisation. Further studies are needed to investigate the use of these techniques in conjunction with each other and the possible use of language learning models. Dedicated studies are required to assess cost efficacy and longer-term outcomes.


Assuntos
Neoplasias da Mama , Ácidos Nucleicos , Linfonodo Sentinela , Humanos , Feminino , Biópsia de Linfonodo Sentinela/métodos , Verde de Indocianina , Metástase Linfática/patologia , Hexafluoreto de Enxofre , Linfonodo Sentinela/patologia , Neoplasias da Mama/patologia , Linfonodos/patologia
15.
Eur J Radiol ; 167: 111060, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37657380

RESUMO

Contrast-enhanced ultrasound (CEUS) is a dependable modality for the diagnosis of various clinical conditions. A judicious selection of ultrasound contrast agent (UCA) is imperative for optimizing imaging and improving diagnosis. Approved UCAs for imaging the majority of organs include SonoVue, a pure blood agent, and Sonazoid, which exhibits an additional Kupffer phase. Despite the fact that the two UCAs are increasingly being employed, there is a lack of comparative reviews between the two agents in different organs diseases. This review represents the first attempt to compare the two UCAs in non-hepatic organs, primarily including breast, thyroid, pancreas, and spleen diseases. Through comparative analysis, this review provides a comprehensive and objective evaluation of the performance characteristics of SonoVue and Sonazoid, with the aim of offering valuable guidance for the clinical application of CEUS. Overall, further clinical evidences are required to compare and contrast the dissimilarities between the two UCAs in non-hepatic organs, enabling clinicians to make an appropriate selection based on actual clinical applications.


Assuntos
Óxidos , Hexafluoreto de Enxofre , Humanos , Ultrassonografia
16.
Radiology ; 308(2): e230150, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37642573

RESUMO

Background Liver Imaging Reporting and Data System (LI-RADS) was designed for contrast-enhanced US (CEUS) with pure blood pool agents to diagnose hepatocellularfcarcinoma (HCC), such as sulfur hexafluoride (SHF), but Kupffer-cell agents, such as perfluorobutane (PFB), allow additional lesion characterization in the Kupffer phase yet remain unaddressed. Purpose To compare the diagnostic performance of three algorithms for HCC diagnosis: two algorithms based on CEUS LI-RADS version 2017 for both SHF and PFB and a modified algorithm incorporating Kupffer-phase findings for PFB. Materials and Methods This multicenter prospective study enrolled high-risk patients for HCC from June 2021 to December 2021. Each participant underwent same-day SHF-enhanced US followed by PFB-enhanced US. Each liver observation was assigned three LI-RADS categories according to each algorithm: LI-RADS SHF, LI-RADS PFB, and modified PFB. For modified PFB, observations at least 10 mm with nonrim arterial phase hyperenhancement were upgraded LR-4 to LR-5 if there was no washout with a Kupffer defect and were reassigned LR-M to LR-5 if there was early washout with mild Kupffer defect. The reference standard was pathologic confirmation or composite (typical CT or MRI features, or 1-year size stability and/or reduction). Diagnostic metrics of LR-5 for HCC using the three algorithms were calculated and compared using the McNemar test. Results Overall, 375 patients (mean age, 56 years ± 11 [SD]; 318 male patients, 57 female patients) with 424 observations (345 HCCs, 40 non-HCC malignancies, 39 benign lesions) were enrolled. PFB and SHF both using LI-RADS showed no significant difference in sensitivity (60% vs 58%; P = .41) and specificity (96% vs 95%; P > .99). The modified algorithm with PFB had increased sensitivity (80% vs 58%; P < .001) and a nonsignificant decrease in specificity (92% vs 95%; P = .73) compared with LI-RADS SHF. Conclusion Based on CEUS LI-RADS version 2017, both SHF and PFB achieved high specificity and relatively low sensitivity for HCC diagnosis. When incorporating Kupffer-phase findings, PFB had higher sensitivity without loss of specificity. Chinese Clinical Trial Registry no. ChiCTR2100047035 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Kim in this issue.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Carcinoma Hepatocelular/diagnóstico por imagem , Hexafluoreto de Enxofre , Estudos Prospectivos , Neoplasias Hepáticas/diagnóstico por imagem
17.
Pract Radiat Oncol ; 13(6): e471-e474, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37414248

RESUMO

Sulfur hexafluoride (SF6) is a widely used insulating gas in medical linear accelerators (LINACs) due to its high dielectric strength, heat transfer capabilities, and chemical stability. However, its long lifespan and high Global Warming Potential (GWP) make it a significant contributor to the environmental impact of radiation oncology. SF6 has an atmospheric lifespan of 3200 years and a GWP 23,000 times that of carbon dioxide. The amount of SF6 that can be emitted through leakage from machines is also concerning. It is estimated that the approximate 15,042 LINACs globally may leak up to 64,884,185.9 carbon dioxide equivalent per year, which is the equivalent greenhouse gas emissions of 13,981 gasoline-powered passenger vehicles driven for 1 year. Despite being regulated as a greenhouse gas under the United Nations Framework Convention on Climate Change, SF6 use within health care is often exempt from regulation, and only a few states in the United States have specific SF6 management regulations. This article highlights the need for radiation oncology centers and LINAC manufacturers to take responsibility for minimizing SF6 emissions. Programs that track usage and disposal, conduct life-cycle assessments, and implement leakage detection can help identify SF6 sources and promote recovery and recycling. Manufacturers are investing in research and development to identify alternative gases, improve leak detection, and minimize SF6 gas leakage during operation and maintenance. Alternative gases with lower GWP, such as nitrogen, compressed air, and perfluoropropane, may be considered as replacements for SF6; however, more research is needed to evaluate their feasibility and performance in radiation oncology. The article emphasizes the need for all sectors, including health care, to reduce their emissions to meet the goals of the Paris Agreement and ensure the sustainability of health care and our patients. Although SF6 is practical in radiation oncology, its environmental impact and contribution to the climate crisis cannot be ignored. Radiation oncology centers and manufacturers must take responsibility for reducing SF6 emissions by implementing best practices and promoting research and development around alternatives. To meet global emissions reduction goals and protect both planetary and patient health, the reduction of SF6 emissions will be essential.


Assuntos
Gases de Efeito Estufa , Radioterapia (Especialidade) , Humanos , Estados Unidos , Dióxido de Carbono/análise , Gases/análise , Hexafluoreto de Enxofre/análise
18.
Environ Pollut ; 335: 122266, 2023 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-37499965

RESUMO

Sulfur hexafluoride (SF6) is a powerful greenhouse gas with a high global warming potential. While SF6 emissions from urban areas have been extensively studied, our knowledge about SF6 concentrations in the oceanic atmosphere and its air-sea exchange remains limited. Herein, the concentrations of SF6 in the atmosphere and surface seawater of the WPO (Western Pacific Ocean) and EIO (Eastern Indian Ocean) were comprehensively characterized from 2019 to 2022 in the first long-term study. The mean mixing ratios of SF6 over the WPO and EIO during 2019-2020 (2021-2022) were 10.9 (11.2) and 10.9 (11.1) ppt, respectively. The atmospheric SF6 concentration over the WPO and EIO increased at rates of 0.40 ± 0.06 and 0.58 ± 0.28 ppt yr-1, respectively, surpassing previously reported annual growth rates. The faster growth was primarily attributed to the influence of polluted air masses originating from eastern Asian countries, particularly Japan, Northeast China, and India. This might explain why the radiative forcing caused by SF6 in the study region was higher than the global average. The concentrations of SF6 in the surface seawater of the WPO and EIO ranged from 0.33 to 2.54 fmol kg-1, and the distribution was affected by atmospheric concentrations and ocean currents. Estimated air-sea fluxes revealed that the ocean acted as a significant sink of atmospheric SF6, and the preliminary estimation suggested oceanic uptake accounts for about 7% of annual global SF6 emissions. Based on these findings, we tentatively suggest that the strength of the ocean as a sink of SF6 may warrant reassessment. The global oceanic uptake of SF6 has the potential to reduce its global abundance and environmental impacts.


Assuntos
Monitoramento Ambiental , Hexafluoreto de Enxofre , Hexafluoreto de Enxofre/análise , Oceano Índico , Água do Mar , Oceano Pacífico , Atmosfera
19.
BMC Ophthalmol ; 23(1): 331, 2023 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-37474921

RESUMO

BACKGROUND: To evaluate the effect of room air and sulfur hexafluoride (SF6) gas in idiopathic macular hole(MH)surgery. METHODS: Retrospective, interventional, and comparative study. 238 eyes with the idiopathic macular hole that underwent pars plana vitrectomy, internal limiting membrane peeling, fluid-air exchange, and 20% SF6 (SF6 group:125 eyes) or room air tamponade (air group: 113 eyes) were reviewed. The primary outcome measure was the closure rate of primary surgery. RESULTS: The baseline characteristics of the SF6 group and air group were comparable except for the hole size (479.90 ± 204.48 vs. 429.38 ± 174.63 µm, P = 0.043). The anatomical closure rate was 92.8% (116 / 125) with the SF6 group and 76.1% (86 / 113) with the air group (P < 0.001). A cut-off value of MH size to predict primary anatomical closure was 520 µm, which is based on the lower limit of 95% confidential interval of the MH size among the unclosed patients in the air group. There was no significant difference in anatomical closure rates between SF6 and air group (98.7% vs. 91.9%, P = 0.051) for MH ≤ 520 µm, whereas a significantly lower anatomical closure rate was shown in the air group than SF6 group (46.2% vs. 84.0%, P < 0.001) for MH > 520 µm. CONCLUSION: SF6 exhibited more effectiveness than air to achieve a good anatomical outcome for its longer tamponade when MH > 520 µm.


Assuntos
Perfurações Retinianas , Humanos , Perfurações Retinianas/cirurgia , Estudos Retrospectivos , Hexafluoreto de Enxofre , Vitrectomia , Acuidade Visual
20.
ACS Sens ; 8(8): 3060-3067, 2023 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-37478418

RESUMO

Sulfur hexafluoride is widely used in power equipment because of its excellent insulation and arc extinguishing properties. However, severe damage to power equipment may be caused and a large-scale collapse of the power grid may occur when SF6 is decomposed into H2S, SOF2, and SO2F2. It is difficult to detect the SF6 concentration as it is a kind of inert gas. Generally, the trace gas decomposed in the early stage of SF6 is detected to achieve the function of early warning. Consequently, it is of great significance to realize the real-time detection of trace gases decomposed from SF6 for the early fault diagnosis of power equipment. In this work, a wafer-scale gate-sensing carbon-based FET gas sensor is fabricated on a four-inch carbon wafer for the detection of H2S, a decomposition product of SF6. The carbon nanotubes with semiconductor properties and the noble metal Pt are respectively used as a channel and a sensing gate of the FET-type gas sensor, and the channel transmission layer and the sensing gate layer each play an independent role and do not interfere with each other by introducing the gate dielectric layer Y2O3, giving full play to their respective advantages to forming an integrated sensor of gas detection and signal amplification. The detection limit of the as-prepared gate-sensing carbon-based FET gas sensor can reach 20 ppb, and its response deviation is not more than 3% for the different batches of gas sensors. This work provides a potentially useful solution for the industrial production of miniaturized and integrated gas sensors.


Assuntos
Sulfeto de Hidrogênio , Nanotubos de Carbono , Gases , Hexafluoreto de Enxofre , Semicondutores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...