Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Anal Chim Acta ; 1010: 76-85, 2018 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-29447674

RESUMO

Bilayer pseudo-stationary phase micellar liquid chromatography (MLC) was developed for simultaneous isocratic isolation of hydrochlorothiazide, as a basic-polar (hydrophilic) cardiovascular drug, as well as triamterene and losartan potassium, as acidic-nonpolar (hydrophobic) cardiovascular drugs. Utilizing a deep eutectic solvent (DES), as a novel green mobile phase additive in combination with acetonitrile (ACN) and acetic acid (ACA), drastically improved the chromatographic behavior of the drugs. Concentration of sodium dodecyl sulphate (SDS), as well as volume percentages of ACN, DES, and ACA were optimized by using a central composite design. The optimal composition of the mobile phase (0.12 mol L-1 SDS, 5% ACN, 4% DES, and 2% ACA) was chosen through the desirability function. The chromatographic peaks of both hydrophilic and hydrophobic drugs, respectively, emerged at high and low retention time values in the shortest total analysis time of 20 min (at a flow rate of 2 mL min-1). Analytical characterization of the developed approach was investigated through Food and Drug Administration (FDA) guidelines. Applicability of the method was evaluated by analysing of human plasma samples which were directly injected into the system.


Assuntos
Fármacos Cardiovasculares/isolamento & purificação , Hidroclorotiazida/isolamento & purificação , Losartan/isolamento & purificação , Projetos de Pesquisa , Triantereno/isolamento & purificação , Fármacos Cardiovasculares/sangue , Fármacos Cardiovasculares/química , Cromatografia Líquida de Alta Pressão , Humanos , Hidroclorotiazida/sangue , Hidroclorotiazida/química , Interações Hidrofóbicas e Hidrofílicas , Losartan/sangue , Losartan/química , Micelas , Software , Triantereno/sangue , Triantereno/química , Estados Unidos , United States Food and Drug Administration
3.
Biomed Chromatogr ; 30(7): 1022-1028, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26542449

RESUMO

This paper reports the applicability of two-phase and three-phase hollow fiber based liquid-phase microextraction (HF-LPME) for the extraction of hydrochlorothiazide (HYD) and triamterene (TRM) from human urine. The HYD in two-phase HF-LPME is extracted from 24 mL of the aqueous sample into an organic phase with microliter volume located inside the pores and lumen of a polypropylene hollow fiber as acceptor phase, but the TRM in three-phase HF-LPME is extracted from aqueous donor phase to organic phase and then back-extracted to the aqueous acceptor phase, which can be directly injected into HPLC for analysis. Under optimized conditions preconcentration factors of HYD and TRM were obtained as 128 and 239, respectively. The calibration curves were linear (R(2) ≥ 0.995) in the concentration range of 1.0-100 µg/L for HYD and 2.0-100 µg/L for TRM. The limits of detection for HYD and TRM were 0.5 µg/L. The intra-day and inter-day RSD based on four replicates were obtained as ≤5.8 and ≤9.3%, respectively. The methods were successfully applied for determining the concentration of the drugs in urine samples. Copyright © 2015 John Wiley & Sons, Ltd.


Assuntos
Diuréticos/isolamento & purificação , Hidroclorotiazida/isolamento & purificação , Microextração em Fase Líquida/métodos , Triantereno/isolamento & purificação , Diuréticos/urina , Humanos , Hidroclorotiazida/urina , Triantereno/urina
4.
Artigo em Inglês | MEDLINE | ID: mdl-26148828

RESUMO

A novel, simple and accurate algorithm capable of extracting the contribution of each component from a mixture signal where the components are completely overlapped was developed. It is based on the development of a coded function which eliminates the signal of interfering components using mean centering as a processing tool; finally the pure contribution of each component is extracted. The algorithm allows the determination of each component as a single one. It was validated by the use of simulated data set of three overlapped signals and tested against simulated random noise. Two fit values were developed and calculated for optimization, one to test that that the absorptivity values of the extracted spectra are within the confidence limits of the slope and the other is the correlation between the pure and extracted spectra. It has been successfully applied to real UV data of binary mixture of Ibuprofen and Paracetamol and ternary mixture of Amiloride hydrochloride, Atenolol and Hydrochlorothiazide in tablets and capsules, respectively. The results were compared to previously reported separation method and no significant difference was found regarding both accuracy and precision.


Assuntos
Acetaminofen/análise , Algoritmos , Amilorida/análise , Atenolol/análise , Hidroclorotiazida/análise , Ibuprofeno/análise , Acetaminofen/isolamento & purificação , Amilorida/isolamento & purificação , Atenolol/isolamento & purificação , Cápsulas/análise , Cápsulas/química , Hidroclorotiazida/isolamento & purificação , Ibuprofeno/isolamento & purificação , Espectrofotometria Ultravioleta , Comprimidos/análise , Comprimidos/química
5.
J Pharm Biomed Anal ; 109: 36-44, 2015 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-25756663

RESUMO

A new rapid stability-indicating UPLC method for separation and determination of impurities in amlodipine besylate, valsartan and hydrochlorothiazide in their combined tablet dosage form was developed. The separation of Ph. Eur. related substances of amlodipine besylate (A, B, D, E, F, G), hydrochlorothiazide (A, B, C), valsartan (B, C), two other valsartan impurities (S)-2-(N-{[2'-cyanobiphenyl-4-yl]methyl}pentanamido)-3-methylbutanoic acid and (S)-3-methyl-2-{[2'-(1H-tetrazol-5-yl)biphenyl-4-yl]methylamino}butanoic acid and several unknown impurities was achieved by reversed phase liquid chromatography with UV detection. The detection wavelengths were set as follows: 225nm for valsartan, its impurities and for the impurity D of amlodipine, 271nm for hydrochlorothiazide and its impurities and 360nm for amlodipine and its impurities except for impurity D. Zorbax Eclipse C8 RRHD (100mm×3.0mm, 1.8µm) was used as a separation column and the analytes were eluted within 11min by a programmed gradient mixture of 0.01M phosphate buffer pH 2.5 and acetonitrile. The method was successfully validated in accordance to the International Conference of Harmonization (ICH) guidelines for amlodipine besylate and its impurity D, valsartan and its impurity C and hydrochlorothiazide and its impurities A, B and C. The triple-combined tablets were exposed to thermal, higher humidity, acid, alkaline, oxidative and photolytic stress conditions. Stressed samples were analyzed by the proposed method. All the significant degradation products and impurities were satisfactory separated from each other and from the principal peaks of drug substances. The peak purity test complied for peaks of amlodipine, valsartan and hydrochlorothiazide in all the stressed samples and indicated no co-elution of degradation products. The method was found to be precise, linear, accurate, sensitive, specific, robust and stability-indicating and could be used as a routine purity test method for amlodipine besylate, valsartan, hydrochlorothiazide and their pharmaceutical combinations.


Assuntos
Anlodipino/isolamento & purificação , Anti-Hipertensivos/isolamento & purificação , Hidroclorotiazida/isolamento & purificação , Valsartana/isolamento & purificação , Anlodipino/química , Anti-Hipertensivos/química , Cromatografia Líquida de Alta Pressão , Combinação de Medicamentos , Estabilidade de Medicamentos , Hidroclorotiazida/química , Limite de Detecção , Padrões de Referência , Reprodutibilidade dos Testes , Soluções , Comprimidos , Valsartana/química
6.
J Sep Sci ; 37(7): 748-57, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24482404

RESUMO

A reversed-phase high-performance liquid chromatography method was developed for the simultaneous determination of the diuretic, hydrochlorothiazide, along with six drugs representing the most commonly prescribed antihypertensive pharmacological classes such as atenolol, a selective ß1 blocker, amlodipine besylate, a calcium channel blocker, moexipril hydrochloride, an angiotensin-converting-enzyme inhibitor, valsartan and candesartan cilexetil, which are angiotensin II receptor blockers, and aliskiren hemifumarate, a renin inhibitor, using irbesartan as an internal standard. The chromatographic separation was achieved using acetonitrile/sodium phosphate dibasic buffer (0.02 M, pH 5.5) at a flow rate of 1 mL/min in gradient elution mode at ambient temperature on a stationary phase composed of an Eclipse XDB-C18 (4.6 × 150 mm, 5 µm) column. UV detection was carried out at 220 nm. The method was validated according to ICH guidelines. Linearity, accuracy, and precision were satisfactory over the concentration ranges of 2-40 µg/mL for hydrochlorothiazide and candesartan cilexetil, 20-120, 10-160, 5-40, 20-250, and 5-50 µg/mL for atenolol, valsartan, moexipril hydrochloride, aliskiren hemifumarate, and amlodipine besylate, respectively. The method was successfully applied for the determination of each of the studied drugs in their combined formulations with hydrochlorothiazide. The developed method is suitable for the quality control and routine analysis of the cited drugs in their pharmaceutical dosage forms.


Assuntos
Anti-Hipertensivos/isolamento & purificação , Química Farmacêutica , Diuréticos/isolamento & purificação , Hidroclorotiazida/isolamento & purificação , Medicamentos sob Prescrição/química , Medicamentos sob Prescrição/isolamento & purificação , Anti-Hipertensivos/química , Cromatografia de Fase Reversa , Diuréticos/química , Hidroclorotiazida/química , Estrutura Molecular
7.
J AOAC Int ; 96(5): 951-9, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24282931

RESUMO

A novel, fast, sensitive, and specific capillary electrophoresis (CE) technique coupled to a diode array detector has been developed for the separation and simultaneous determination of carvedilol (CRV) and hydrochlorothiazide (HCT) in two combination formulations. The proposed method utilized a fused silica capillary (55 cm x75 microm id) and the background electrolyte solution phosphate buffer (12.5 mM, pH 7.4)-methanol (95+5, v/v). The separation was achieved at 30 kV applied voltage and 24 degree C. Atorvastatin (80 microg/mL) was chosen as the internal standard. The described method was linear over the range of 1-200 and 0.2-150 microg/mL for CRV and HCT, respectively. Intraday and interday RSD (n = 6) was < or =1.4%. The LOD values of CRV and HCT were 0.26 and 0.07 microg/mL, respectively. The validated CE method was successfully applied to the analysis of two commercial tablet dosage forms. Forced degradation studies were performed on bulk samples of the two drugs using thermal, photolytic, hydrolytic, and oxidative stress conditions, and the stressed samples were analyzed by the proposed method. Degradation products produced as a result of stress studies did not interfere with the determination of CRV and HCT; the assay could, therefore, be considered stability-indicating.


Assuntos
Carbazóis/isolamento & purificação , Eletroforese Capilar/métodos , Hidroclorotiazida/isolamento & purificação , Propanolaminas/isolamento & purificação , Soluções Tampão , Carbazóis/análise , Carbazóis/química , Carvedilol , Química Farmacêutica , Combinação de Medicamentos , Estabilidade de Medicamentos , Hidroclorotiazida/análise , Hidroclorotiazida/química , Concentração de Íons de Hidrogênio , Propanolaminas/análise , Propanolaminas/química , Comprimidos , Temperatura
8.
J Chromatogr Sci ; 51(1): 92-7, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22752183

RESUMO

The current manuscript reports the first capillary electrophoresis method for the separation and quantification of metoprolol (MET) and hydrochlorothiazide (HCT) in their combined dosage form. MET and HCT were detected at 240 and 214 nm, respectively, using a photodiode array detector. The univariate approach was used for optimizing voltage, injection time and capillary temperature. The factorial design with response surface plots, as a multivariate approach, was used to study the effect of buffer concentration and pH on resolution, peak area and migration time. The optimum conditions were 50 mmol/L phosphate at pH 9.5, injection time 10.0 s, voltage 25 kV and capillary temperature 25°C. The method was linear in the range of 2.5-250 µg/mL for both drugs with correlation coefficients above 0.9997. Additionally, acceptable recovery of the contents of MET and HCT in their formulations (96.0-100.3%) with acceptable precision (1.38-2.60 %) were achieved. Moreover, the limits of detection of MET and HCT were 0.02 and 0.01 µg/mL, respectively, which were suitable for pharmaceutical analysis.


Assuntos
Eletroforese Capilar/métodos , Hidroclorotiazida/análise , Metoprolol/análise , Combinação de Medicamentos , Hidroclorotiazida/química , Hidroclorotiazida/isolamento & purificação , Limite de Detecção , Metoprolol/química , Metoprolol/isolamento & purificação , Análise Multivariada , Reprodutibilidade dos Testes , Comprimidos/química
9.
Drug Test Anal ; 3(6): 345-51, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21548141

RESUMO

Forensic analysis of pharmaceutical preparations requires a comparative analysis with a standard of the suspected drug in order to identify the active ingredient. Purchasing analytical standards can be expensive or unattainable from the drug manufacturers. Direct Analysis in Real Time (DART™) is a novel, ambient ionization technique, typically coupled with a JEOL AccuTOF™ (accurate mass) mass spectrometer. While a fast and easy technique to perform, a drawback of using DART™ is the lack of component separation of mixtures prior to ionization. Various in-house pharmaceutical preparations were purified using thin-layer chromatography (TLC) and mass spectra were subsequently obtained using the AccuTOF™- DART™ technique. Utilizing TLC prior to sample introduction provides a simple, low-cost solution to acquiring mass spectra of the purified preparation. Each spectrum was compared against an in-house molecular formula list to confirm the accurate mass elemental compositions. Spectra of purified ingredients of known pharmaceuticals were added to an in-house library for use as comparators for casework samples. Resolving isomers from one another can be accomplished using collision-induced dissociation after ionization. Challenges arose when the pharmaceutical preparation required an optimized TLC solvent to achieve proper separation and purity of the standard. Purified spectra were obtained for 91 preparations and included in an in-house drug standard library. Primary standards would only need to be purchased when pharmaceutical preparations not previously encountered are submitted for comparative analysis. TLC prior to DART™ analysis demonstrates a time efficient and cost saving technique for the forensic drug analysis community. Copyright © 2011 John Wiley & Sons, Ltd.


Assuntos
Ciências Forenses/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Preparações Farmacêuticas/análise , Preparações Farmacêuticas/isolamento & purificação , Cromatografia em Camada Fina/métodos , Hidroclorotiazida/análise , Hidroclorotiazida/isolamento & purificação , Lisinopril/análise , Lisinopril/isolamento & purificação , Mescalina/análise , Mescalina/isolamento & purificação , Metaproterenol/análise , Metaproterenol/isolamento & purificação , Comprimidos/química
10.
J Sep Sci ; 34(5): 542-7, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21344645

RESUMO

A tandem solid-phase extraction method (SPE) of connecting two different cartridges (C(18) and MCX) in series was developed as the extraction procedure in this article, which provided better extraction yields (>86%) for all analytes and more appropriate sample purification from endogenous interference materials compared with a single cartridge. Analyte separation was achieved on a C(18) reversed-phase column at the wavelength of 265 nm by high-performance liquid chromatography (HPLC). The method was validated in terms of extraction yield, precision and accuracy. These assays gave mean accuracy values higher than 89% with RSD values that were always less than 3.8%. The method has been successfully applied to plasma samples from rats after oral administration of target compounds.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Hidroclorotiazida/sangue , Hidroclorotiazida/isolamento & purificação , Reserpina/sangue , Reserpina/isolamento & purificação , Extração em Fase Sólida/métodos , Triantereno/sangue , Triantereno/isolamento & purificação , Animais , Diuréticos/sangue , Diuréticos/isolamento & purificação , Ratos
11.
Water Res ; 45(3): 1432-42, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21122885

RESUMO

The occurrence of fifty-five pharmaceuticals, hormones and metabolites in raw waters used for drinking water production and their removal through a drinking water treatment were studied. Thirty-five out of fifty-five drugs were detected in the raw water at the facility intake with concentrations up to 1200 ng/L. The behavior of the compounds was studied at each step: prechlorination, coagulation, sand filtration, ozonation, granular activated carbon filtration and post-chlorination; showing that the complete treatment accounted for the complete removal of all the compounds detected in raw waters except for five of them. Phenytoin, atenolol and hydrochlorothiazide were the three pharmaceuticals most frequently found in finished waters at concentrations about 10 ng/L. Sotalol and carbamazepine epoxide were found in less than a half of the samples at lower concentrations, above 2 ng/L. However despite their persistence, the removals of these five pharmaceuticals were higher than 95%.


Assuntos
Hormônios/análise , Hormônios/isolamento & purificação , Preparações Farmacêuticas/análise , Preparações Farmacêuticas/isolamento & purificação , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/isolamento & purificação , Purificação da Água/métodos , Abastecimento de Água/análise , Atenolol/análise , Atenolol/química , Atenolol/isolamento & purificação , Carbamazepina/análogos & derivados , Carbamazepina/análise , Carbamazepina/química , Carbamazepina/isolamento & purificação , Hormônios/química , Hidroclorotiazida/análise , Hidroclorotiazida/química , Hidroclorotiazida/isolamento & purificação , Ozônio/química , Preparações Farmacêuticas/química , Fenitoína/análise , Fenitoína/química , Fenitoína/isolamento & purificação , Sotalol/análise , Sotalol/química , Sotalol/isolamento & purificação , Poluentes Químicos da Água/química
12.
J Chromatogr Sci ; 48(7): 595-600, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20819286

RESUMO

A simple and precise stability-indicating liquid chromatography method is developed and validated for the quantitative simultaneous estimation of irbesartan (IRB) and hydrochlorothiazide (HCTZ) in combined pharmaceutical dosage form. A chromatographic separation of the two drugs was achieved with an Ace5 C(18) 25-cm analytical column using buffer-acetonitrile (70:30 v/v). The buffer used in mobile phase contains 50 mM ammonium acetate pH adjusted 5.5 with acetic acid. The instrumental settings are flow rate of 1.5 mL/min, column temperature at 30 degrees C, and detector wavelength of 235 nm using a photodiode array detector. IRB, HCTZ, and their combination drug products were exposed to thermal, photolytic, hydrolytic, and oxidative stress conditions, and the stressed samples were analyzed by the proposed method. Peak homogeneity data of IRB and HCTZ is obtained using photodiode array detector. In the stressed sample chromatograms, it demonstrated the specificity of the assay method for their estimation in presence of degradation products. The described method shows excellent linearity over a range of 10-200 microg/mL for IRB and 5-100 microg/mL for HCTZ. Methylparaben was used as internal standard. The correlation coefficient for IRB and HCTZ are 0.998 and 0.999. The mean recovery values for IRB and HCTZ ranged from 100.45% to 101.25%. The limit of detection for IRB and HCTZ were 0.019 and 0.023 microg/mL, respectively, and the limit of quantification were 0.053 and 0.070 microg/mL, respectively. The proposed method was suitable for quantitative determination and stability study of IRB and HCTZ in pharmaceutical preparations and also can be used in the quality control of bulk manufacturing and pharmaceutical dosage forms.


Assuntos
Compostos de Bifenilo/análise , Cromatografia Líquida de Alta Pressão/métodos , Hidroclorotiazida/análise , Tetrazóis/análise , Compostos de Bifenilo/química , Compostos de Bifenilo/isolamento & purificação , Química Farmacêutica , Combinação de Medicamentos , Estabilidade de Medicamentos , Hidroclorotiazida/química , Hidroclorotiazida/isolamento & purificação , Irbesartana , Modelos Lineares , Parabenos/análise , Parabenos/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tetrazóis/química , Tetrazóis/isolamento & purificação
13.
Talanta ; 80(1): 363-71, 2009 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-19782237

RESUMO

A simple and sensitive method for simultaneous analysis of 43 pharmaceutical compounds in sewage sludge and sediment samples was developed and validated. The target compounds were extracted using pressurized liquid extraction (PLE) and then purified and pre-concentrated by solid phase extraction (SPE) using a hydrophilic-lipophilic balanced polymer. PLE extraction was performed on temperature of 100 degrees C, with methanol/water mixture (1/2, v/v) as extraction solvent. The quantitative analysis was performed by liquid chromatography tandem mass spectrometry using a hybrid triple quadrupole-linear ion trap mass spectrometer (LC-QqLIT-MS). Data acquisition was carried out in selected reaction monitoring (SRM) mode, monitoring two SRM transitions to ensure an accurate identification of target compounds in the samples. Additional identification and confirmation of target compounds were performed using the Information Dependent Acquisition (IDA) function. The method was validated through the estimation of the linearity, sensitivity, repeatability, reproducibility and matrix effects. The internal standard approach was used for quantification because it efficiently corrected matrix effects. Despite the strong matrix interferences, the recoveries were generally higher of 50% in both matrixes and the detection and quantification limits were very low. Beside the very good sensitivity provided by LC-QqLIT-MS, an important characteristic of the method is that all the target compounds can be simultaneously extracted, treated and analysed. Hence, it can be used for routine analysis of pharmaceuticals providing large amount of data. The method was applied for the analysis of pharmaceuticals in river sediment and wastewater sludge from three treatment plants with different treatment properties (i.e. capacity, secondary treatment, quality of influent waters). The analysis showed a widespread occurrence of pharmaceuticals in the sludge matrices.


Assuntos
Cromatografia Líquida/métodos , Sedimentos Geológicos/análise , Preparações Farmacêuticas/análise , Esgotos/química , Espectrometria de Massas em Tandem/métodos , Acetaminofen/análise , Acetaminofen/isolamento & purificação , Atorvastatina , Cromatografia Líquida/instrumentação , Diclofenaco/análise , Diclofenaco/isolamento & purificação , Sedimentos Geológicos/química , Ácidos Heptanoicos/análise , Ácidos Heptanoicos/isolamento & purificação , Temperatura Alta , Hidroclorotiazida/análise , Hidroclorotiazida/isolamento & purificação , Ibuprofeno/análise , Ibuprofeno/isolamento & purificação , Preparações Farmacêuticas/isolamento & purificação , Preparações Farmacêuticas/normas , Pirróis/análise , Pirróis/isolamento & purificação , Padrões de Referência , Reprodutibilidade dos Testes , Rios , Extração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/instrumentação
14.
J Pharm Biomed Anal ; 48(1): 212-7, 2008 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-18584987

RESUMO

In this paper, a combination of multi-syringe chromatography analysis technique with extraction disks sorbents for the pre-concentration and determination of hydrochlorothiazide and losartan potassium in superficial water, groundwater and wastewater outlet samples has been developed. The system developed was proved for the determination of hydrochlorothiazide and losartan potassium in spiked water samples with recoveries ranging from 95 to 118%. The method involves the on-line enrichment of the targeted analytes from spiked water samples onto a Cation-SR sorbent material. The analytes are subsequently eluted and transported to the monolithic column, Chromolith Flash RP-18e column (25 mmx4.6 mm i.d.). The mobile phase used was 10 mM potassium dihydrogen phosphate (pH 3.0):acetonitrile:methanol (60:30:10 v/v/v), flow-rate 0.8 mL min(-1). UV detection is carried out at 226 nm. Under the optimized chemical and physical variables, the detection limit for hydrochlorothiazide and losartan potassium calculated as 3Syx/b was 0.07 and 0.09 mgL(-1), respectively, for a sample loading volume of 1.0 mL.


Assuntos
Anti-Hipertensivos/análise , Água Doce/análise , Hidroclorotiazida/análise , Losartan/análise , Sistemas On-Line , Poluentes Químicos da Água/análise , Água/análise , Anti-Hipertensivos/química , Anti-Hipertensivos/isolamento & purificação , Cromatografia/instrumentação , Hidroclorotiazida/química , Hidroclorotiazida/isolamento & purificação , Losartan/química , Losartan/isolamento & purificação , Estrutura Molecular , Extração em Fase Sólida/métodos , Água/química
15.
Anal Bioanal Chem ; 391(6): 2349-56, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18500512

RESUMO

This contribution describes use of a separation method based on on-line coupling of a multisyringe flow system with a chromatographic monolithic column for simultaneous determination of hydrochlorothiazide and losartan potassium in tablets. The system comprised a multisyringe module, three low-pressure solenoid valves, a monolithic C(18) column (25 mm x 4.6 mm i.d.), and a diode-array detector. The mobile phase was 10 mmol L(-1) potassium dihydrogen phosphate (pH 3.1)-acetonitrile-methanol (65:33:2 v/v/v) at a flow rate 0.8 mL min(-1). UV detection was carried out at 226 nm. The multi-syringe chromatographic (MSC) method with UV spectrophotometric detection was optimized and validated. Results from validation were very good. The analysis time was about 400 s. The method was found to be applicable to routine analysis of both compounds in tablets. The coupling of the monolithic columns with a multi-syringe flow-injection analysis manifold provides an excellent and inexpensive tool to solve the separation problems without use of HPLC instrumentation.


Assuntos
Cromatografia Líquida de Alta Pressão/instrumentação , Hidroclorotiazida/isolamento & purificação , Losartan/isolamento & purificação , Comprimidos/química , Cromatografia Líquida de Alta Pressão/métodos , Desenho de Equipamento , Hidroclorotiazida/análise , Losartan/análise
16.
J Pharm Sci ; 90(11): 1800-9, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11745738

RESUMO

Hydrochlorothiazide (6-chloro-3,4-dihydro-2H-1,2,4-benzothiadiazine-7-sulfonamide 1,1-dioxide) (HCTZ) 1 is a widely used diuretic and anti-hypertensive. Recently, the Pharmeuropa recognized a new impurity initially thought to be an HCTZ dimer 6, which consists of the active drug (HCTZ) linked via the former beta-ring methylene to a known degradate, 5-chloro-2,4-disulfamylaniline 2. In an effort to meet a new requirement, an analytical high-pressure liquid chromatography method was developed that was selective and sensitive to the subject impurity. The impurity was concentrated and purified using a combination of solid phase extraction and reverse-phase high-pressure liquid chromatography. Subsequently, the impurity has been identified as a specific HCTZ-CH2-HCTZ isomer utilizing a variety of analytical techniques, including hydrolysis, ultraviolet spectroscopy, liquid chromatography/mass spectrometry, and 1H and 13C nuclear magnetic resonance (NMR) spectroscopy. The data resulting from the application of these analytical techniques confirm the identity of the impurity as a methylene bridged pair of HCTZ molecules; however, a total of six possible isomers 7a-f exist because of the presence of three reactive amines/sulfonamides on each HCTZ molecule. One unique molecular structure (4-[[6-chloro-3,4,-dihydro-2H-1,2,4-benzothiadiazine-7-sulfonamide-1,1-dioxide]-methyl]-chloro-3-hydro-H-1,2,4-benzothiadiazine-7-sulfonamide-1,1-dioxide) 7f was identified using two-dimensional COSY, NOESY, and TOCSY 1H NMR experiments.


Assuntos
Anti-Hipertensivos/isolamento & purificação , Hidroclorotiazida/isolamento & purificação , Anti-Hipertensivos/química , Contaminação de Medicamentos , Hidroclorotiazida/química , Espectroscopia de Ressonância Magnética/métodos
17.
Electrophoresis ; 20(12): 2366-72, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10499327

RESUMO

A capillary electrochromatography (CEC) method has been developed for the separation of theophylline, caffeine and five related drugs on a normal-phase column with UV or photodiode array detection. Several binary, ternary and quaternary mobile phase compositions are evaluated for optimal resolution and elution of these drug analytes. The importance of selecting suitable organic solvents, buffer electrolyte, pH and applied voltage is demonstrated by a systematic study. Excellent separation is achieved for the eight drugs using a ternary mobile phase composition of isopropanol/hexane/1 mM Tris (52:40:8, pH 8), with an efficiency of 63000 theoretical plates per meter at room temperature. Detection limits are typically at the low microg/mL level. The developed method is simple to use and it gives acceptable day-to-day reproducibility.


Assuntos
Cafeína/isolamento & purificação , Cromatografia Líquida de Alta Pressão/métodos , Eletroforese Capilar/métodos , Teofilina/isolamento & purificação , Acetaminofen/química , Acetaminofen/isolamento & purificação , Cafeína/química , Difilina/isolamento & purificação , Condutividade Elétrica , Hidroclorotiazida/química , Hidroclorotiazida/isolamento & purificação , Estrutura Molecular , Niacina/isolamento & purificação , Fenilbutazona/química , Fenilbutazona/isolamento & purificação , Teobromina/química , Teobromina/isolamento & purificação , Teofilina/análogos & derivados , Teofilina/química
18.
J Assoc Off Anal Chem ; 66(6): 1436-42, 1983 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-6643354

RESUMO

A liquid chromatographic (LC) method, using a reverse phase C18 column, an acetic acid-methanol-water mobile phase, and detection at 280 nm, was developed for the determination of methyldopa in tablets and oral suspensions and combinations of methyldopa with hydrochlorothiazide or chlorothiazide in tablets. A mixture of these 3 drugs was resolved in less than 8 min. Detector responses were linear for the following amounts (mg/mL) of drug injected: methyldopa 0.031-0.393, chlorothiazide 0.019-0.114, and hydrochlorothiazide 0.004-0.083. Recoveries from commercial dosage forms ranged from 99.1 to 100.9% for methyldopa, 99.2-100.4% for chlorothiazide, and 100.0-101.2% for hydrochlorothiazide. Replicate injections of methyldopa, chlorothiazide, and hydrochlorothiazide standard preparations alone or in combination gave overall relative standard deviations of less than 1.6% (n = 10). The results for methyldopa tablets by the proposed method were in agreement with those obtained by the USP XX method. The LC method detected as little as 0.6 micrograms 3-O-methylmethyldopa/mL and 0.5 micrograms 4-amino-6-chloro-1,3-benzenedisulfonamide/mL, which are sometimes found as contaminants of methyldopa and thiazides, respectively, and resolved methyldopa from its methyldopa glucose adduct, a substance found in methyldopa oral suspensions.


Assuntos
Clorotiazida/isolamento & purificação , Hidroclorotiazida/isolamento & purificação , Metildopa/isolamento & purificação , Cromatografia Líquida , Combinação de Medicamentos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA