Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
Anesth Analg ; 133(2): 423-434, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33177323

RESUMO

BACKGROUND: Several opioids are metabolized by the inducible cytochrome P450 (CYP) 3A isozymes. Coadministration with strong inducers of drug metabolism, such as rifampin, can dramatically reduce systemic exposure to these opioids. As the CYP metabolism of hydromorphone is of minor importance, we studied in healthy volunteers whether hydromorphone would be an effective analgesic for patients who concomitantly receive the prototypical enzyme inducer rifampin. METHODS: In this paired, randomized, crossover study, 12 participants received oral placebo or rifampin for 8 days. Oral hydromorphone (2.6 mg) was administered on day 6 followed by intravenous hydromorphone (0.02 mg/kg) on day 8. Hydromorphone and hydromorphone-3-glucuronide (HM3G) plasma concentrations were measured for 24 hours and psychomotor responses, including perceived drug effect, change in pupil diameter, and cold pressor threshold were evaluated for 6 hours. Our primary outcome was the change in the area under the concentration-time curve (AUC0-last) of oral and intravenous hydromorphone after pretreatment with rifampin or placebo. Pharmacodynamic parameters and other pharmacokinetic parameters were analyzed as secondary outcomes. RESULTS: Rifampin reduced the AUC0-last of oral and intravenous hydromorphone by 43% (ratio to control: 0.57, 90% confidence interval [CI], 0.50-0.65) and 26% (ratio to control: 0.74, 90% CI, 0.69-0.79), respectively. The maximum concentration of oral hydromorphone was reduced by 37% (ratio to control: 0.63, 90% CI, 0.55-0.72), and oral bioavailability decreased from 33% to 26% (ratio to control: 0.78, 90% CI, 0.67-0.91) in the rifampin phase compared with placebo. The HM3G-to-hydromorphone ratio increased by 50% (90% CI, 25-79) and 42% (90% CI, 29-55) after oral and intravenous hydromorphone, respectively. Rifampin did not significantly affect the pharmacodynamic parameters. CONCLUSIONS: Rifampin significantly reduces the concentrations of oral and intravenous hydromorphone. This interaction is due to an increase in the first-pass and systemic metabolism of hydromorphone, likely involving induction of uridine 5'-diphospho- glucuronosyltransferase enzymes by rifampin. The enhancement of hydromorphone elimination should be considered when managing pain of patients who are treated with strong enzyme inducers.


Assuntos
Analgésicos Opioides/sangue , Indutores do Citocromo P-450 CYP3A/administração & dosagem , Hidromorfona/sangue , Rifampina/administração & dosagem , Administração Intravenosa , Administração Oral , Adulto , Analgésicos Opioides/administração & dosagem , Analgésicos Opioides/farmacocinética , Estudos Cross-Over , Citocromo P-450 CYP3A/metabolismo , Indutores do Citocromo P-450 CYP3A/efeitos adversos , Método Duplo-Cego , Interações Medicamentosas , Feminino , Finlândia , Glucuronatos/sangue , Voluntários Saudáveis , Humanos , Hidromorfona/administração & dosagem , Hidromorfona/análogos & derivados , Hidromorfona/farmacocinética , Inativação Metabólica , Masculino , Rifampina/efeitos adversos , Adulto Jovem
2.
Anesth Analg ; 130(4): 1035-1044, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31206429

RESUMO

BACKGROUND: Opioids remain the mainstay of cancer pain management but are associated with systemic toxicity. In refractory cancer pain, intrathecal therapy (ITT) is associated with improved pain control, reduced systemic side effects, and improved survival. It has been assumed that ITT decreases systemic serum opioid levels and their associated toxicity, but there are limited data to support this assumption. This study hypothesizes that serum opioid levels decrease with ITT. Secondary objectives include comparative measures of pain, bowel function, and other cancer-related symptoms. METHODS: Fifty-one cancer patients undergoing ITT for cancer pain were recruited in a prospective observational study. Daily oral morphine equivalency (OME) dose, serum opioid levels, Brief Pain Inventory (BPI), MD Anderson Symptom Inventory (MDASI), and a constipation questionnaire were obtained at the time of implant, and 4 and 8 weeks postoperatively. RESULTS: Average baseline daily OME was 375 mg (median, 240; interquartile range, 150-405; range, 0-3160), mean serum morphine concentration was 53.7 ng/mL (n = 17), and mean oxycodone concentration was 73.7 ng/mL (n = 20). At 4 weeks, 87.5% of patients had discontinued non-IT opioids, and 53% had undetectable (<2 ng/mL) serum opioid concentrations. At 8 weeks, 92% remained off all non-IT opioids and 59% had undetectable serum opioid levels. IT morphine doses >4.2 mg/d were invariably associated with detectable serum levels; with doses <4.2 mg, morphine was undetectable in 80% of subjects. IT hydromorphone doses >6.8 mg/d were detectable in the serum. Using linear mixed model analyses, there were statistically significant decreases in the mean "worst pain," "average pain," and MD Anderson symptom severity and interference scores at 4 and 8 weeks. This change was independent of serum opioid levels; when analyzed separately, there was no difference in the pain scores of subjects with detectable serum opioid levels compared to those with undetectable levels at 4 and 8 weeks. Constipation ranked as "quite a bit" or "very much" decreased from 58.7% to 19.2% of subjects at week 4 (P < .001) and to 37.5% at 8 weeks (P = .23). A very low complication rate was observed. CONCLUSIONS: ITT for cancer pain was associated with a marked reduction in serum opioid concentrations, with the majority of patients having undetectable serum levels. Reducing serum opioid concentrations in cancer patients may have implications with respect to restoring bowel function, improving fatigue, and promoting the integrity of antitumor immune function and warrants further study.


Assuntos
Analgésicos Opioides/sangue , Analgésicos Opioides/uso terapêutico , Dor do Câncer/tratamento farmacológico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Analgésicos Opioides/administração & dosagem , Constipação Intestinal/induzido quimicamente , Constipação Intestinal/epidemiologia , Feminino , Humanos , Hidromorfona/administração & dosagem , Hidromorfona/sangue , Hidromorfona/uso terapêutico , Injeções Espinhais , Masculino , Pessoa de Meia-Idade , Neoplasias/complicações , Neoplasias/cirurgia , Medição da Dor/efeitos dos fármacos , Dor Pós-Operatória/tratamento farmacológico , Estudos Prospectivos , Resultado do Tratamento , Adulto Jovem
3.
Biomed Chromatogr ; 32(12): e4357, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30074252

RESUMO

A simple high-performance liquid chromatography method for the determination of hydromorphone in small volume plasma has been developed. Following solid-phase extraction using Oasis HLB cartridges, samples were separated by reverse-phase high-performance liquid chromatography on an Atlantis T3 4.6 × 150 mm column (3.0 µm) and quantified using mass spectrometry. The mobile phase was a mixture of water with 0.1% formic acid and acetonitrile with 0.1% formic acid (91:9). The standard curve ranged from 1 to 500 ng/mL. Intra- and Inter-assay variability for hydromorphone was <10%, and the average recovery was >90%. The LLOQ was 1 ng/mL. This method was successfully applied to the analysis of hydromorphone samples at this institution. This method could be useful to those investigators dealing with small sample volumes, particularly when conducting pharmacokinetic studies that require multiple sampling from the same animal.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Hidromorfona/sangue , Hidromorfona/farmacocinética , Espectrometria de Massas/métodos , Estabilidade de Medicamentos , Humanos , Hidromorfona/química , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes , Extração em Fase Sólida
4.
J Anal Toxicol ; 42(5): e47-e49, 2018 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-29462321

RESUMO

Our laboratory received segments of umbilical cord that originated from identical twins for routine toxicology analysis. The specimens were analyzed multiple times by liquid chromatography tandem mass spectrometry. The umbilical cord from newborn #1 was positive for hydromorphone only (1.06 ng/g), and the umbilical cord from newborn #2 was positive for hydromorphone (0.81 ng/g) and benzoylecgonine (5.41 ng/g). The hydromorphone results are consistent with maternal administration of hydromorphone; however, the cause of the discrepant benzoylecgonine results in the umbilical cords from the identical twins is unknown.


Assuntos
Analgésicos Opioides/sangue , Cocaína/análogos & derivados , Sangue Fetal/química , Hidromorfona/sangue , Drogas Ilícitas/sangue , Troca Materno-Fetal , Gêmeos Monozigóticos , Analgésicos Opioides/química , Cromatografia Líquida de Alta Pressão , Cocaína/sangue , Cocaína/química , Transtornos Relacionados ao Uso de Cocaína/sangue , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Hidromorfona/química , Drogas Ilícitas/química , Recém-Nascido , Triagem Neonatal , Gravidez , Complicações na Gravidez/sangue , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray , Detecção do Abuso de Substâncias , Espectrometria de Massas em Tandem
5.
Eur J Drug Metab Pharmacokinet ; 42(1): 17-28, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26797808

RESUMO

BACKGROUND AND OBJECTIVE: We recently developed a new population pharmacokinetic model for hydromorphone in patients including age and bodyweight as covariates. The aim of the present study was to evaluate prospectively the predictive performance of this new model during postoperative pain therapy. METHODS: This was a prospective, single-blinded, randomized, single-center study with two parallel arms. Fifty patients aged 40-85 years undergoing cardiac surgery involving thoracotomy were enrolled. Hydromorphone was administered postoperatively on the intensive care unit as target controlled infusion (TCI) for patient controlled analgesia (TCI-PCA) using the new pharmacokinetic model, or as conventional patient controlled analgesia (PCA). Arterial blood samples were taken for measurement of the hydromorphone plasma concentration. The predictive performance of the pharmacokinetic model was assessed by the median performance error (MDPE), the median absolute performance error (MDAPE), wobble and divergence. For comparison, the performance indices were also determined for three older models from the literature. RESULTS: 903 plasma concentrations of 41 patients were analyzed. The mean values (95 % CI) of MDPE, MDAPE, wobble and divergence for the new pharmacokinetic model were 11.2 % (3.9 to 18.7 %), 28.5 % (23.9 to 33.0 %), 21.4 % (18.0 to 24.9 %) and -1.6 %/h (-2.3 to -0.8 %/h). When compared with older models from the literature, performance was better with less overshoot after bolus doses. CONCLUSION: The new pharmacokinetic model of hydromorphone showed a good precision and a better performance than older models. It is therefore suitable for TCI with hydromorphone during postoperative pain therapy. TRIAL REGISTRATION: EudraCT 2013-002875-16, Clinical Trials NCT02035709.


Assuntos
Analgésicos Opioides/farmacocinética , Hidromorfona/farmacocinética , Modelos Biológicos , Dor Pós-Operatória/tratamento farmacológico , Adulto , Idoso , Idoso de 80 Anos ou mais , Analgesia Controlada pelo Paciente/estatística & dados numéricos , Analgésicos Opioides/administração & dosagem , Analgésicos Opioides/sangue , Anestésicos Intravenosos/sangue , Anestésicos Intravenosos/farmacocinética , Cálculos da Dosagem de Medicamento , Feminino , Humanos , Hidromorfona/administração & dosagem , Hidromorfona/sangue , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Método Simples-Cego , Toracotomia/métodos
6.
Anesthesiology ; 124(1): 56-68, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26556729

RESUMO

BACKGROUND: Patient-controlled analgesia (PCA) is a common method for postoperative pain therapy, but it is characterized by large variation of plasma concentrations. PCA with target-controlled infusion (TCI-PCA) may be an alternative. In a previous analysis, the authors developed a pharmacokinetic model for hydromorphone. In this secondary analysis, the authors investigated the feasibility and efficacy of TCI-PCA for postoperative pain therapy with hydromorphone. METHODS: Fifty adult patients undergoing cardiac surgery were enrolled in this study. Postoperatively, hydromorphone was applied intravenously during three sequential periods: (1) as TCI with plasma target concentrations of 1 to 2 ng/ml until extubation; (2) as TCI-PCA with plasma target concentrations between 0.8 and 10 ng/ml during the following 6 to 8 h; and (3) thereafter as PCA with a bolus dose of 0.2 mg until the next morning. During TCI-PCA, pain was regularly assessed using the 11-point numerical rating scale (NRS). A pharmacokinetic/pharmacodynamic model was developed using ordinal logistic regression based on measured plasma concentrations. RESULTS: Data of 43 patients aged 40 to 81 yr were analyzed. The hydromorphone dose during TCI-PCA was 0.26 mg/h (0.07 to 0.93 mg/h). The maximum plasma target concentration during TCI-PCA was 2.3 ng/ml (0.9 to 7.0 ng/ml). The NRS score under deep inspiration was less than 5 in 83% of the ratings. Nausea was present in 30%, vomiting in 9%, and respiratory insufficiency in 5% of the patients. The EC50 of hydromorphone for NRS of 4 or less was 4.1 ng/ml (0.6 to 12.8 ng/ml). CONCLUSION: TCI-PCA with hydromorphone offered satisfactory postoperative pain therapy with moderate side effects.


Assuntos
Analgesia Controlada pelo Paciente , Analgésicos Opioides/farmacologia , Hidromorfona/farmacologia , Dor Pós-Operatória/tratamento farmacológico , Adulto , Idoso , Idoso de 80 Anos ou mais , Analgésicos Opioides/administração & dosagem , Analgésicos Opioides/sangue , Feminino , Humanos , Hidromorfona/administração & dosagem , Hidromorfona/sangue , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
7.
Am J Vet Res ; 76(9): 763-70, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26309104

RESUMO

OBJECTIVE: To evaluate the pharmacokinetics of hydrocodone (delivered in combination with acetaminophen) and tramadol in dogs undergoing tibial plateau leveling osteotomy (TPLO). ANIMALS: 50 client-owned dogs. PROCEDURES: Dogs were randomly assigned to receive tramadol hydrochloride (5 to 7 mg/kg, PO, q 8 h; tramadol group) or hydrocodone bitartrate-acetaminophen (0.5 to 0.6 mg of hydrocodone/kg, PO, q 8 h; hydrocodone group) following TPLO with standard anesthetic and surgical protocols. Blood samples were collected for pharmacokinetic analysis of study drugs and their metabolites over an 8-hour period beginning after the second dose of the study medication. RESULTS: The terminal half-life, maximum serum concentration, and time to maximum serum concentration for tramadol following naïve pooled modeling were 1.56 hours, 155.6 ng/mL, and 3.90 hours, respectively. Serum concentrations of the tramadol metabolite O-desmethyltramadol (M1) were low. For hydrocodone, maximum serum concentration determined by naïve pooled modeling was 7.90 ng/mL, and time to maximum serum concentration was 3.47 hours. The terminal half-life for hydrocodone was 15.85 hours, but was likely influenced by delayed drug absorption in some dogs and may not have been a robust estimate. Serum concentrations of hydromorphone were low. CONCLUSIONS AND CLINICAL RELEVANCE: The pharmacokinetics of tramadol and metabolites were similar to those in previous studies. Serum tramadol concentrations varied widely, and concentrations of the active M1 metabolite were low. Metabolism of hydrocodone to hydromorphone in dogs was poor. Further study is warranted to assess variables that affect metabolism and efficacy of these drugs in dogs.


Assuntos
Hidrocodona/farmacocinética , Hidromorfona/farmacocinética , Dor Pós-Operatória/veterinária , Tramadol/farmacocinética , Acetaminofen/sangue , Acetaminofen/farmacocinética , Acetaminofen/uso terapêutico , Analgésicos Opioides/farmacocinética , Animais , Área Sob a Curva , Cães , Meia-Vida , Hidrocodona/uso terapêutico , Hidromorfona/sangue , Hidromorfona/metabolismo , Osteotomia/efeitos adversos , Osteotomia/veterinária , Dor Pós-Operatória/tratamento farmacológico , Tramadol/análogos & derivados , Tramadol/sangue , Tramadol/metabolismo , Tramadol/uso terapêutico
8.
Clin Biochem ; 48(18): 1283-90, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26118474

RESUMO

OBJECTIVES: Development and validation of a selective, robust high-performance liquid chromatography-tandem mass spectrometric (HPLC/MS-MS) method for the quantification of morphine, morphine-3-ß-glucuronide, morphine-6-ß-glucuronide, hydromorphone, and normorphine in human serum. DESIGN AND METHODS: Drug-free human serum samples spiked with morphine, morphine-3-ß-glucuronide, morphine-6-ß-glucuronide, hydromorphone, and normorphine were prepared by protein precipitation using methanol containing the internal standards. Samples were injected onto a Thermo Scientific AccuCore PFP column for chromatographic separation. Detection was achieved using a Thermo Scientific TSQ Vantage mass spectrometer. Assay validation followed the new Clinical and Laboratory Standards Institute (CLSI) C62-A guidelines. RESULTS: The analytical measuring range for all analytes was determined to be 5 to 1000 ng/mL. Intra- and inter-assay precision for three quality control levels were ≤ 7.0% and ≤ 13.5%, respectively. Carryover, stability, linearity, matrix effects, extraction and processing efficiency and method comparison characteristics were acceptable relative to the CLSI C62 guidelines. CONCLUSION: The validation of this HPLC-MS/MS method demonstrated a robust and rapid assay for the quantification of morphine, morphine-3-ß-glucuronide, morphine-6-ß-glucuronide, hydromorphone, and normorphine.


Assuntos
Analgésicos Opioides/sangue , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/normas , Guias como Assunto , Humanos , Hidromorfona/sangue , Modelos Lineares , Morfina/sangue , Derivados da Morfina/sangue , Variações Dependentes do Observador , Padrões de Referência , Espectrometria de Massas em Tandem/normas
9.
J Clin Pharmacol ; 55(9): 975-84, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25807927

RESUMO

This single dose, open-label study investigated the safety, tolerability and pharmacokinetics of single oral doses of newly formulated immediate-release (IR) and hydrophilic matrix extended-release (ER) hydromorphone tablets in healthy Japanese subjects without co-administration of an opioid antagonist under fasting and fed conditions. Plasma and urinary concentrations of hydromorphone and metabolites were measured by liquid-chromatography tandem mass-spectroscopy. Following administration of the ER tablet, plasma concentrations of hydromorphone slowly increased with a median tmax of 5.0 h and the Cmax decreased to 37% of the IR tablet, while the AUC0-inf was comparable with that of the IR tablet when administered at the same dose. The degree of fluctuation in the plasma concentration for the ER tablet was much lower than that of the IR tablet and certain levels of plasma concentrations were maintained after 24 h of ER dosing. The AUC0-inf and Cmax increased with food for both IR and ER tablets. The AUC0-inf of hydromorphone-3-glucoside was one-tenth of that of hydromorphone-3-glucuronide. A single oral administration of the hydromorphone tablets would be well-tolerated in healthy Japanese subjects despite a lack of co-administration of an opioid antagonist and the newly developed ER hydromorphone tablets may have the appropriate PK characteristics for once-daily dosing.


Assuntos
Analgésicos Opioides/efeitos adversos , Analgésicos Opioides/farmacocinética , Hidromorfona/efeitos adversos , Hidromorfona/farmacocinética , Adulto , Analgésicos Opioides/administração & dosagem , Analgésicos Opioides/sangue , Área Sob a Curva , Povo Asiático , Estudos Cross-Over , Preparações de Ação Retardada , Quimioterapia Combinada , Interações Alimento-Droga , Glucuronatos/sangue , Glucuronatos/metabolismo , Meia-Vida , Humanos , Hidromorfona/administração & dosagem , Hidromorfona/análogos & derivados , Hidromorfona/sangue , Hidromorfona/metabolismo , Masculino , Pessoa de Meia-Idade , Adulto Jovem
10.
J Anal Toxicol ; 38(8): 495-506, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25217537

RESUMO

High-resolution mass spectrometry (HRMS) is being applied in postmortem drug screening as an alternative to nominal mass spectrometry, and additional evaluation in quantitative casework is needed. We report quantitative analysis of benzoylecgonine, citalopram, cocaethylene, cocaine, codeine, dextromethorphan, dihydrocodeine, diphenhydramine, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine, hydrocodone, hydromorphone, meperidine, methadone, morphine, oxycodone and oxymorphone in postmortem blood by ultra-performance liquid chromatography (UPLC)-MS(E)/time-of-flight (TOF). The method employs analyte-matched deuterated internal standardization and MS(E) acquisition of precursor and product ions at low (6 eV) and ramped (10-40 eV) collision energies, respectively. Quantification was performed using precursor ion data obtained with a mass extraction window of ± 5 ppm. Fragment and residual precursor ion acquisitions at ramped collision energies were evaluated as additional analyte identifiers. Extraction recovery of >60% and matrix effect of <20% were determined for all analytes and internal standards. Defined limits of detection (10 ng/mL) and quantification (25 ng/mL) were validated along with a linearity analytical range of 25-3,000 ng/mL (R(2) > 0.99) for all analytes. Parallel UPLC-MS(E)/TOF and UPLC-MS/MS analysis showed comparable precision and bias along with concordance of 253 positive (y = 1.002x + 1.523; R(2) = 0.993) and 2,269 negative analyte findings in 159 postmortem cases. Analytical performance and correlation studies demonstrate accurate quantification by UPLC-MS(E)/TOF and extended application of HRMS in postmortem casework.


Assuntos
Análise Química do Sangue/métodos , Cromatografia Líquida/métodos , Patologia Legal/métodos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos , Citalopram/sangue , Cocaína/análogos & derivados , Cocaína/sangue , Codeína/análogos & derivados , Codeína/sangue , Dextrometorfano/sangue , Difenidramina/sangue , Estudos de Avaliação como Assunto , Humanos , Hidrocodona/sangue , Hidromorfona/sangue , Meperidina/sangue , Metadona/sangue , Morfina/sangue , Oxicodona/sangue , Oximorfona/sangue , Pirrolidinas/sangue , Controle de Qualidade , Reprodutibilidade dos Testes
11.
Am J Vet Res ; 75(6): 527-31, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24866507

RESUMO

OBJECTIVE: To determine the pharmacokinetics of hydromorphone hydrochloride after IV and IM administration in American kestrels (Falco sparverius). ANIMALS: 12 healthy adult American kestrels. PROCEDURES: A single dose of hydromorphone (0.6 mg/kg) was administered IM (pectoral muscles) and IV (right jugular vein); the time between IM and IV administration experiments was 1 month. Blood samples were collected at 5 minutes, 1 hour, and 3 hours (n = 4 birds); 0.25, 1.5, and 9 hours (4); and 0.5, 2, and 6 hours (4) after drug administration. Plasma hydromorphone concentrations were determined by means of liquid chromatography with mass spectrometry, and pharmacokinetic parameters were calculated with a noncompartmental model. Mean plasma hydromorphone concentration for each time was determined with naïve averaged pharmacokinetic analysis. RESULTS: Plasma hydromorphone concentrations were detectable in 2 and 3 birds at 6 hours after IM and IV administration, respectively, but not at 9 hours after administration. The fraction of the hydromorphone dose absorbed after IM administration was 0.75. The maximum observed plasma concentration was 112.1 ng/mL (5 minutes after administration). The terminal half-life was 1.25 and 1.26 hours after IV and IM administration, respectively. CONCLUSION AND CLINICAL RELEVANCE: Results indicated hydromorphone hydrochloride had high bioavailability and rapid elimination after IM administration, with a short terminal half-life, rapid plasma clearance, and large volume of distribution in American kestrels. Further studies regarding the effects of other doses, other administration routes, constantrate infusions, and slow release formulations on the pharmacokinetics of hydromorphone hydrochloride and its metabolites in American kestrels may be indicated.


Assuntos
Analgésicos Opioides/farmacocinética , Falconiformes/metabolismo , Hidromorfona/farmacocinética , Administração Intravenosa/veterinária , Analgésicos Opioides/administração & dosagem , Analgésicos Opioides/sangue , Animais , Área Sob a Curva , Disponibilidade Biológica , Cromatografia Líquida/veterinária , Estudos Cross-Over , Meia-Vida , Hidromorfona/administração & dosagem , Hidromorfona/sangue , Injeções Intramusculares/veterinária , Espectrometria de Massas/veterinária , Modelos Biológicos , Fatores de Tempo , Estados Unidos
12.
Pain ; 154(12): 2794-2800, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23973378

RESUMO

Opioids are commonly prescribed to patients with chronic pain associated with end-stage renal disease requiring hemodialysis. The stability of opioid analgesia during dialysis may vary among different opioids. No studies to date have corroborated this clinical observation by directly comparing plasma concentrations of different opioids during dialysis. We compared changes in peridialysis plasma concentrations of 2 pharmacokinetically distinct opioids, methadone and hydromorphone (HM). Fourteen dialysis patients with chronic pain received either methadone or HM for at least 2 weeks before beginning the study. Blood samples were obtained immediately before, during, and after hemodialysis in 2 separate dialysis sessions, 1 week apart, and were analyzed for opioid concentrations. Methadone plasma concentrations were more stable during hemodialysis compared to HM: the mean percent change of methadone plasma levels was 14.9% ± 8.2% (± SD) compared with 55.1% ± 8.1% in the HM treatment group, a difference of 40.2% (95% confidence interval 17.14 to 63.14). The mean plasma clearance of methadone was 19.9 ± 8.5 mL/min (± SD) compared with 105.7 ± 8.3 mL/min for HM, a difference of 85.7 mL/min (95% confidence interval 61.9 to 109.1). There were no differences between the 2 opioid groups in pain scores, side effect profile, and quality of life. Methadone therapy was not associated with an increased rate of adverse events. If confirmed by larger clinical studies, methadone could be considered as one of the opioids of choice in dialysis patients.


Assuntos
Analgésicos Opioides/sangue , Hidromorfona/sangue , Falência Renal Crônica/sangue , Falência Renal Crônica/terapia , Taxa de Depuração Metabólica/fisiologia , Metadona/sangue , Diálise Renal , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Diálise Renal/métodos
13.
Pain Physician ; 16(3): E227-35, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23703421

RESUMO

BACKGROUND: Postoperative pain management remains a challenge for clinicians due to unpredictable patient responses to opioid therapy. Some of this variability may result from single nucleotide polymorphisms (SNPs) of the human opioid mu-1 receptor (OPRM1) that modify receptor binding or signal transduction. The OPRM1 variant with the highest frequency is the A118G SNP. However, previous studies have produced inconsistent results regarding the clinical effects of A118G on opioid response. We hypothesized that measurement of serum opioid concentrations, in addition to determining total opioid consumption, may provide a more precise method of assessing the effects of A118G on analgesic response. The current study evaluated the relationship of analgesia, side effects, total hydrocodone consumption, quantitative serum hydrocodone and hydromorphone concentrations, and A118G SNP in postoperative patients following Cesarean section. METHODS: 158 women scheduled for Cesarean section were enrolled prospectively in the study. The patients had bupivacaine spinal anesthesia for surgery and received intrathcal morphine with the spinal anesthetic or parenteral morphine for the first 24 hours after surgery. Thereafter, patients received hydrocodone/acetaminophen for postoperative pain control. On postoperative day 3, venous blood samples were obtained for OPRM1 A118G genotyping and serum opioid concentrations. RESULTS: 131 (82.9%) of the subjects were homozygous for the 118A allele of OPRM1 (AA) and 27 (17.1%) carried the G allele (AG/GG). By regression analysis, pain relief was significantly associated with total hydrocodone dose in the AA group (P = 0.01), but not in the AG/GG group (P = 0.554). In contrast, there was no association between pain relief and serum hydrocodone concentration in either group. However, pain relief was significantly associated with serum hydromorphone concentration (a metabolite of hydrocodone) in the AA group (P = 0.004), but not in the AG/GG group (P = 0.724). Conversely, side effects were significantly higher (P < 0.04) in the AG/GG group (mean = 6.4) than in the AA group (mean = 4.4), regardless of adjustment for BMI, pain level, or total dose of hydrocodone. CONCLUSION: This study found a correlation between pain relief and total hydrocodone dose in patients homozygous for the 118A allele (AA) of the OPRM1 gene, but not in patients with the 118G allele (AG/GG). However, pain relief in 118A patients did not correlate with serum hydrocodone concentrations, but rather with serum hydromorphone levels, the active metabolite of hydrocodone. This suggests that pain relief with hydrocodone may be due primarily to hydromorphone. Although pain relief did not correlate with opioid dose in AG/GG patients, they had a higher incidence of opioid side effects. The correlations identified in this study may reflect the fact that serum opioid concentrations were measured directly, avoiding the inherent imprecision associated with relying solely on total opioid consumption as a determinant of opioid effectiveness. Thus, measurement of serum opioid concentrations is recommended when assessing the role of OPRM1 variants in pain relief. This study supports pharmacogenetic analysis of OPRM1 in conjunction with serum opioid concentrations when evaluating patient responses to opioid therapy.


Assuntos
Analgésicos Opioides/uso terapêutico , Hidrocodona/uso terapêutico , Hidromorfona/sangue , Hidromorfona/metabolismo , Dor Pós-Operatória , Farmacogenética , Adolescente , Adulto , Analgésicos Opioides/sangue , Cromatografia Líquida , Feminino , Genótipo , Humanos , Hidrocodona/sangue , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Obstétricos/efeitos adversos , Dor Pós-Operatória/sangue , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/genética , Polimorfismo de Nucleotídeo Único/genética , Receptores Opioides mu/genética , Espectrometria de Massas em Tandem , Adulto Jovem
14.
Vet Anaesth Analg ; 40(5): 537-45, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23601353

RESUMO

OBJECTIVE: To evaluate the pharmacokinetics, in dogs, of liposome-encapsulated oxymorphone and hydromorphone made by the ammonium sulfate gradient loading technique (ASG). ANIMALS: Four healthy purpose-bred Beagles aged 9.5 ± 3.2 months and weighing 13.4 ± 2.3 kg. STUDY DESIGN: Randomized cross-over design. METHODS: Each dog was given either 4.0 mg kg(-1) of ASG-oxymorphone or 8.0 mg kg(-1) of ASG-hydromorphone SC on separate occasions with a 3-month washout period. Blood was collected at baseline and at serial time points up to 1032 hours (43 days) after injection for determination of serum opioid concentrations. Serum opioid concentrations were measured with HPLC-MS and pharmacokinetic parameters were calculated using commercial software and non-compartmental methods. RESULTS: Serum concentrations of oxymorphone remained above the limit of quantification for 21 days, while those for hydromorphone remained above the limit of quantification for 29 days. Cmax for ASG-oxymorphone was 7.5 ng mL(-1) ; Cmax for ASG-hydromorphone was 5.7 ng mL(-1) . CONCLUSIONS AND CLINICAL RELEVANCE: Oxymorphone and hydromorphone, when encapsulated into liposomes using the ammonium sulfate gradient loading technique, result in measureable serum concentrations for between 3 to 4 weeks. This formulation may have promise in the convenient use of opioids for clinical treatment of chronically painful conditions in dogs.


Assuntos
Sulfato de Amônio/química , Cães/sangue , Hidromorfona/farmacocinética , Lipossomos , Oximorfona/farmacocinética , Analgésicos Opioides/administração & dosagem , Analgésicos Opioides/sangue , Analgésicos Opioides/química , Analgésicos Opioides/farmacocinética , Animais , Área Sob a Curva , Meia-Vida , Hidromorfona/administração & dosagem , Hidromorfona/sangue , Hidromorfona/química , Masculino , Oximorfona/administração & dosagem , Oximorfona/sangue , Oximorfona/química
15.
Artigo em Inglês | MEDLINE | ID: mdl-23523877

RESUMO

A selective, sensitive and accurate high-performance liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for the quantitation of hydrocodone, hydromorphone and norhydrocodone in human plasma was developed. The internal standard stock solution comprised of hydrocodone-d6, hydromorphone-d6 and norhydrocodone-d3 was added to 0.5 mL plasma samples. Samples were extracted using a copolymeric sorbent (mixed mode) solid phase extraction (SPE) column. Chromatographic separation was carried out using a reversed-phase C18 analytical column with a gradient mobile phase consisting of solvent A=5% acetonitrile with 0.1% formic acid and solvent B=100% acetonitrile. MS analysis was performed using positive electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode. Linearity was established over the range 1-100 ng/mL with correlation coefficients ≥0.998 for all three analytes. The coefficient of variation (CV) of intra-day samples was ≤5.6% at 10 ng/mL. The precision of inter-day (6 days) samples resulted in CVs ≤8.1% at concentrations tested at 2.5, 10 and 25 ng/mL for all three analytes. The lower limit of quantification (LOQ) was 1.0 ng/mL with signal-to-noise (S/N) ratio >10, the limit of detection (LOD) was 0.25 ng/mL with S/N ratio >3 for the drug and its metabolites. Dilution effects, extraction recovery, stability, interference, carryover and ion suppression were also evaluated. This method was successfully applied to human subject plasma samples in support of a hydrocodone pharmacokinetic study.


Assuntos
Cromatografia Líquida/métodos , Hidrocodona/sangue , Hidromorfona/sangue , Espectrometria de Massas em Tandem/métodos , Estabilidade de Medicamentos , Humanos , Hidrocodona/análogos & derivados , Hidrocodona/farmacocinética , Hidromorfona/farmacocinética , Modelos Lineares , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Vet J ; 196(2): 266-8, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23098635

RESUMO

The purpose of this study was to determine the pharmacokinetics of hydrocodone and its active metabolite hydromorphone in six healthy Greyhound dogs. Hydrocodone bitartrate was administered at a targeted dose of 0.5 mg/kg PO. Plasma concentrations of hydrocodone and hydromorphone were determined by liquid chromatography triple quadrupole mass spectrometry. The mean hydrocodone CMAX was 11.73 ng/mL at 0.74 h with a terminal half-life of 1.60 h. The mean hydromorphone CMAX was 5.2 ng/mL at 1.37 h with a terminal half-life of 3.07 h. Mean plasma hydromorphone concentrations exceeded 2 ng/mL from 0.5 to 8 h after hydrocodone administration. Further studies assessing the antinociceptive effects of oral hydrocodone are needed.


Assuntos
Cães/sangue , Hidrocodona/farmacocinética , Hidromorfona/farmacocinética , Acetaminofen/administração & dosagem , Animais , Área Sob a Curva , Cães/metabolismo , Combinação de Medicamentos , Meia-Vida , Hidrocodona/sangue , Hidrocodona/metabolismo , Hidromorfona/sangue , Hidromorfona/metabolismo
17.
J Pharm Biomed Anal ; 71: 63-70, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22884788

RESUMO

A method for a sensitive and specific analysis of hydromorphone total and unbound drug concentrations in human plasma was developed and validated. Sample preparation was preceded with an ultrafiltration step to separate the unbound drug from the protein bound fraction of hydromorphone. Both the ultrafiltrate and plasma samples were extracted with solid-phase extraction and substituted with stable isotope-labeled hydromorphone that was used as internal standard. Chromatographic separation was performed by gradient elution with UPLC-like system and eluates were analyzed by tandem mass spectrometry equipped with an electrospray ionization source. Sample preparation was optimized for good recovery of hydromorphone and the results were consistent. Calibration curves demonstrated linearity in the concentration range of 78-5000pg/ml for analysis of both total and unbound concentrations of hydromorphone. The limit of detection was 1pg and the lower limit of quantification was 78pg/ml for both total and unbound hydromorphone plasma drug concentrations. Intra- and interassay reproducibility and inaccuracy did not exceed 10%. Hydromorphone was on the average 14% bound to plasma proteins, supporting the previously published unreferenced statements that the protein binding of hydromorphone is low. Method was applied to a clinical trial in patients undergoing open heart surgery to generate a target controlled infusion model for the postoperative patient controlled analgesia with hydromorphone.


Assuntos
Analgésicos Opioides/sangue , Procedimentos Cirúrgicos Cardíacos/métodos , Cromatografia Líquida/métodos , Hidromorfona/sangue , Dor Pós-Operatória/sangue , Dor Pós-Operatória/tratamento farmacológico , Ultrafiltração/métodos , Analgesia Controlada pelo Paciente , Analgésicos Opioides/administração & dosagem , Analgésicos Opioides/química , Analgésicos Opioides/farmacocinética , Calibragem , Humanos , Hidromorfona/administração & dosagem , Hidromorfona/química , Hidromorfona/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Extração em Fase Sólida/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos
18.
J Pharm Biomed Anal ; 61: 15-21, 2012 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-22169470

RESUMO

A sensitive reverse phase high performance liquid chromatography-electrospray ionization-mass spectrometry (RP-HPLC-ESI-MS) method has been developed and validated for the determination of hydromorphone in human plasma using naloxone as the internal standard (IS). After alkalization with saturated sodium bicarbonate, the plasma samples were extracted with ethyl acetate. Chromatographic separation was performed on a C18 column with the column temperature of 50 °C and a mobile phase of 5mM ammonium acetate buffer containing 1% formic acid-methanol (88:12, v/v). Hydromorphone and the IS were detected by selected ion monitoring using the protonated molecules at m/z 286.2 for hydromorphone and m/z 328.2 for the IS. Calibration curve was linear over the range of 0.01-50 ng/mL. The lower limit of quantification was 0.01 ng/mL. The method was successfully applied to the pharmacokinetic study in postoperative patients after intravenous infusion of 1.5mg hydromorphone hydrochloride. The obtained main pharmacokinetic parameters of hydromorphone in postoperative patients were as follows: the maximum hydromorphone plasma concentration (C(max)) was (24.15 ± 12.51)ng/mL, the time to the C(max) was (10.0 ± 0.0)min, and the elimination half-life was (2.7 ± 0.8)h.


Assuntos
Cromatografia de Fase Reversa/métodos , Hidromorfona/administração & dosagem , Hidromorfona/farmacocinética , Bombas de Infusão , Cuidados Pós-Operatórios , Espectrometria de Massas por Ionização por Electrospray/métodos , Adolescente , Adulto , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Cromatografia de Fase Reversa/normas , Feminino , Humanos , Hidromorfona/sangue , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Cuidados Pós-Operatórios/métodos , Espectrometria de Massas por Ionização por Electrospray/normas , Adulto Jovem
19.
J Anal Toxicol ; 35(2): 99-107, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21396229

RESUMO

Opioids are frequently encountered in Forensic Toxicology casework. A PubMed literature search was conducted to find a method using electron impact-gas chromatography-mass spectrometry to examine whole blood specimens. A previously published method was identified, and an updated version was provided by the State of North Carolina Office of the Chief Medical Examiner. This procedure was used as a starting point for development and validation of a refined procedure to be used in the Palm Beach County Sheriff's Office Forensic Toxicology laboratory for routine analysis of antemortem forensic toxicology case samples. Materials and instrumentation common to most forensic toxicology laboratories were utilized while obtaining detection limits from 1 to 10 ng/mL and quantitation limits of 2.5 to 10 ng/mL using 1 mL of whole blood. Target compounds were chosen based on applicability to the method as well as availability and common use in the United States and include dihydrocodeine, codeine, morphine, hydrocodone, 6-monoacetylmorphine, hydromorphone, oxycodone, and oxymorphone. Each analyte demonstrated two zero-order linear ranges (r(2) > 0.990) over the concentrations evaluated (from 2.5 to 500 ng/mL). The coefficient of variation of replicate analyses was less than 12%. Quantitative accuracy was within ± 27% at 2.5 ng/mL, ± 11% at 10 ng/mL, and ± 8% at 50 ng/mL. The validated method provides a more sensitive procedure for the quantitation of common opioids in blood using standard laboratory equipment and a small amount of sample.


Assuntos
Analgésicos Opioides/sangue , Detecção do Abuso de Substâncias/métodos , Analgésicos Opioides/química , Codeína/análogos & derivados , Codeína/sangue , Codeína/química , Toxicologia Forense , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Hidrocodona/sangue , Hidrocodona/química , Hidromorfona/sangue , Hidromorfona/química , Morfina/sangue , Morfina/química , Derivados da Morfina/sangue , Derivados da Morfina/química , Oxicodona/sangue , Oxicodona/química , Oximorfona/sangue , Oximorfona/química
20.
J Opioid Manag ; 6(2): 87-94, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20481173

RESUMO

BACKGROUND: The 3-glucuronide metabolites of morphine and hydromorphone have been implicated as a causative factor for patients exhibiting myoclonus. OBJECTIVE: The primary goal of this study was to determine plasma levels of morphine-3-glucuronide (M3G) or hydromorphone-3-glucuronide (H3G) in patients demonstrating myoclonus and identify any trends or associations between the two. SETTING: Patients were recruited from San Diego Hospice and the Institute for Palliative Medicine's inpatient unit. DESIGN: A prospective convenience sample comprised of 17 subjects, 12 with myoclonus and 5 without myoclonus. Analysis included demographic, metabolic and clinical variables. Plasma was assayed via high performance liquid chromatography for morphine, M3G, and morphine-6-glucuronide or hydromorphone and hydromorphone-3-glucuronide. RESULTS: No trends or associations were identified between plasma levels of M3G or H3G and myoclonus. Ratio levels of 3-glucuronide metabolite to their corresponding parent opioid were dramatically lower than anticipated. CONCLUSION: In this small pilot study, it appears that the serum levels of metabolites M3G and H3G do not correlate with myoclonus.


Assuntos
Analgésicos Opioides/metabolismo , Glucuronídeos/sangue , Hidromorfona/metabolismo , Morfina/metabolismo , Mioclonia/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Analgésicos Opioides/efeitos adversos , Analgésicos Opioides/sangue , Estudos de Coortes , Feminino , Glucuronatos/sangue , Humanos , Hidromorfona/efeitos adversos , Hidromorfona/análogos & derivados , Hidromorfona/sangue , Masculino , Desintoxicação Metabólica Fase II , Pessoa de Meia-Idade , Morfina/efeitos adversos , Morfina/sangue , Derivados da Morfina/sangue , Mioclonia/etiologia , Dor/tratamento farmacológico , Cuidados Paliativos , Projetos Piloto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...