Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Sci Rep ; 14(1): 378, 2024 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-38172327

RESUMO

Sweat is an essential protection system for the body, but its failure can result in pathologic conditions, including several skin diseases, such as palmoplantar pustulosis (PPP). As reduced intraepidermal E-cadherin expression in skin lesions was confirmed in PPP skin lesions, a role for interleukin (IL)-1-rich sweat in PPP has been proposed, and IL-1 has been implicated in the altered E-cadherin expression observed in both cultured keratinocytes and mice epidermis. For further investigation, live imaging of sweat perspiration on a mouse toe-pad under two-photon excitation microscopy was performed using a novel fluorescent dye cocktail (which we named JSAC). Finally, intraepidermal vesicle formation which is the main cause of PPP pathogenesis was successfully induced using our "LASER-snipe" technique with JSAC. "LASER-snipe" is a type of laser ablation technique that uses two-photon absorption of fluorescent material to destroy a few acrosyringium cells at a pinpoint location in three-dimensional space of living tissue to cause eccrine sweat leakage. These observatory techniques and this mouse model may be useful not only in live imaging for physiological phenomena in vivo such as PPP pathomechanism investigation, but also for the field of functional physiological morphology.


Assuntos
Psoríase , Pele , Animais , Camundongos , Pele/metabolismo , Suor/metabolismo , Psoríase/metabolismo , Epiderme/metabolismo , Glândulas Écrinas/metabolismo , Interleucina-1/metabolismo , Imagem Óptica/efeitos adversos , Caderinas/metabolismo
2.
Thyroid ; 34(1): 64-69, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37897089

RESUMO

Background: The impact of near-infrared autofluorescence (NIRAF) imaging on postthyroidectomy hypocalcemia is controversial. As patients with Graves' disease are at increased risk, our aim was to compare postoperative parathyroid function in these patients undergoing total thyroidectomy (TT) with or without NIRAF imaging. Methods: This was a retrospective "before and after" study, comparing outcomes of patients who underwent TT without or with NIRAF imaging at a single center. Primary outcome was the incidence of temporary hypocalcemia and secondary outcomes, rates of incidental parathyroidectomy on final specimens and permanent hypocalcemia. Analyses were performed using Mann-Whitney U and chi-Square tests. Continuous data are expressed as median (interquartile range). Results: There were 85 patients in NIRAF and 100 patients in non-NIRAF group. Groups were comparable regarding age, gender, body-mass index, and thyroid weight. Number of parathyroid glands identified intraoperatively was 3 in both groups (p = 0.47). Intraoperative parathyroid implantation rate was 16.5% in NIRAF and 6% in non-NIRAF group (p = 0.02). Incidental parathyroidectomy rate on final pathology was 12.9% in NIRAF and 32% in non-NIRAF group (p = 0.002). The rates of temporary (11.7% vs. 16%) and permanent hypocalcemia (2.4% vs. 2%) were similar between the two groups, respectively (p = 0.66). Conclusion: To our knowledge, this is the first comparative study investigating the impact of NIRAF on postoperative parathyroid function after thyroidectomy for Graves' disease. The rate of incidental parathyroidectomy on final pathology was lower with use of NIRAF, without an impact on temporary or permanent hypocalcemia rates compared to conventional technique.


Assuntos
Doença de Graves , Hipocalcemia , Humanos , Tireoidectomia/efeitos adversos , Tireoidectomia/métodos , Hipocalcemia/etiologia , Estudos Retrospectivos , Complicações Pós-Operatórias/etiologia , Glândulas Paratireoides/diagnóstico por imagem , Glândulas Paratireoides/cirurgia , Paratireoidectomia/métodos , Doença de Graves/diagnóstico por imagem , Doença de Graves/cirurgia , Doença de Graves/complicações , Imagem Óptica/efeitos adversos , Imagem Óptica/métodos
3.
Pancreatology ; 24(1): 130-136, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38016861

RESUMO

BACKGROUND: Laparoscopic duodenum-preserving pancreatic head resection (LDPPHR) is a surgical method used to treat benign and low-grade malignant pancreatic head tumors. This study aimed to determine the protective effect of common bile duct in LDPPHR using indocyanine green (ICG) fluorescence imaging. METHODS: A retrospective analysis of 30 patients treated with LDPPHR at the Second Affiliated Hospital of Nanchang University between January 2015 and November 2022 was performed. Patients were divided into two groups based on ICG use: ICG and non-ICG. RESULTS: Thirty patients received LDPPHR, 11 males and 19 females, and the age was 50.50 (M (IQR)) years (range: 19-76 years). LDPPHR was successfully performed in 27 (90 %) patients, LPD was performed in 1 (3 %) patient, and laparotomy conversion was performed in 2 (7 %) patients. One patient (3 %) died 21 days after surgery. The incidence of intraoperative bile duct injury in the ICG group was lower than that in the non-ICG group (10 % vs 60 %, P = 0.009), and the operation time in the ICG group was shorter than that in the non-ICG group (311.9 ± 14.97 vs 338.05 ± 18.75 min, P < 0.05). Postoperative pancreatic fistula occurred in 16 patients (53 %), including 10 with biochemical leakage (62.5 %), four with grade B (25 %), and two with grade C (12.5 %). Postoperative bile leakage occurred in four patients (13 %). CONCLUSIONS: The ICG fluorescence imaging technology in LDPPHR helps protect the integrity of the common bile duct and reduce the occurrence of intraoperative bile duct injury, postoperative bile leakage, and bile duct stenosis.


Assuntos
Doenças dos Ductos Biliares , Laparoscopia , Masculino , Feminino , Humanos , Verde de Indocianina , Estudos Retrospectivos , Laparoscopia/métodos , Doenças dos Ductos Biliares/etiologia , Imagem Óptica/efeitos adversos , Imagem Óptica/métodos , Duodeno/diagnóstico por imagem , Duodeno/cirurgia
4.
JAMA Otolaryngol Head Neck Surg ; 149(3): 253-260, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36633855

RESUMO

Importance: Identification and preservation of parathyroid glands (PGs) remain challenging despite advances in surgical techniques. Considerable morbidity and even mortality result from hypoparathyroidism caused by devascularization or inadvertent removal of PGs. Emerging imaging technologies hold promise to improve identification and preservation of PGs during thyroid surgery. Observation: This narrative review (1) comprehensively reviews PG identification and vascular assessment using near-infrared autofluorescence (NIRAF)-both label free and in combination with indocyanine green-based on a comprehensive literature review and (2) offers a manual for possible implementation these emerging technologies in thyroid surgery. Conclusions and Relevance: Emerging technologies hold promise to improve PG identification and preservation during thyroidectomy. Future research should address variables affecting the degree of fluorescence in NIRAF, standardization of signal quantification, definitions and standardization of parameters of indocyanine green injection that correlate with postoperative PG function, the financial effect of these emerging technologies on near-term and longer-term costs, the adoption learning curve and effect on surgical training, and long-term outcomes of key quality metrics in adequately powered randomized clinical trials evaluating PG preservation.


Assuntos
Hipoparatireoidismo , Glândulas Paratireoides , Humanos , Glândulas Paratireoides/diagnóstico por imagem , Glândulas Paratireoides/cirurgia , Glândula Tireoide/diagnóstico por imagem , Glândula Tireoide/cirurgia , Verde de Indocianina , Imagem Óptica/efeitos adversos , Imagem Óptica/métodos , Tireoidectomia/métodos , Hipoparatireoidismo/etiologia
5.
Int J Colorectal Dis ; 38(1): 7, 2023 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-36625972

RESUMO

PURPOSE: The purpose of this study was to clarify the usefulness of indocyanine green fluorescence imaging (ICG-FI) in the assessment of intestinal vascular perfusion in patients who receive intracorporeal anastomosis (IA) in colon cancer surgery. METHODS: This was a single-center, retrospective study using propensity score matching. We compared the surgical outcomes of colon cancer patients who underwent laparoscopic colonic resection with IA or external anastomosis (EA) with the intraoperative evaluation of anastomotic perfusion using ICG-FI from January 2019 to July 2021. The detection rate of poor anastomotic perfusion by ICG-FI was examined. RESULTS: A total of 223 patients were enrolled. After matching, 69 patients each were classified into the IA and EA groups. There were no significant differences in age, sex, body mass index, tumor localization, or progression between the two groups. The operation time was similar (172 min vs. 171 min, p = 0.62) and the amount of bleeding was significantly lower (0 ml vs. 2 ml, p = 0.0023) in the IA group. The complication rates (grade ≥ 2) of the two groups were similar (14.5% vs. 11.6%, p = 0.59). ICG-FI identified four patients (5.8%) with poor anastomotic perfusion in the IA group, but none in the EA group (p = 0.046). All four patients with poor perfusion in the IA group underwent additional resection; none of these patients developed postoperative complications. CONCLUSION: Poor anastomotic perfusion was detected in 5.8% of cases who underwent laparoscopic colon cancer surgery with IA. ICG-FI is useful for evaluating anastomotic perfusion in IA in order to prevent AL.


Assuntos
Neoplasias do Colo , Neoplasias Colorretais , Laparoscopia , Humanos , Verde de Indocianina , Neoplasias Colorretais/cirurgia , Estudos Retrospectivos , Fístula Anastomótica/etiologia , Neoplasias do Colo/diagnóstico por imagem , Neoplasias do Colo/cirurgia , Neoplasias do Colo/complicações , Anastomose Cirúrgica/efeitos adversos , Laparoscopia/efeitos adversos , Perfusão/efeitos adversos , Imagem Óptica/efeitos adversos , Imagem Óptica/métodos
6.
Respir Med ; 207: 107114, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36608860

RESUMO

BACKGROUND: Medical thoracoscopy (MT) does not always provide a conclusive diagnosis of pleural diseases because the endoscopic appearance of pleural diseases can be misleading. Autofluorescence imaging (AFI) is an effective assistive diagnostic tool. However, its clinical application for pleural disease remains controversial. OBJECTIVES: This prospective study evaluated the clinical usefulness of AFI-assisted MT for diagnosis of malignant pleural diseases. METHODS: Patients with unexplained pleural effusion admitted to our clinics between December 2018 and September 2021 were enrolled. We performed white-light thoracoscopy (WLT) first, and then AFI, during MT. Images of endoscopic real-time lesions were recorded under both modes. Pleural biopsy specimens were analyzed pathologically. Between-groups differences in diagnostic sensitivity, specificity, positive-predictive value (PPV), and negative-predictive value (NPV) were assessed using 95% confidence intervals (CI). Receiver operating characteristic curves and decision curve analyses were employed to analyze the diagnostic efficiency of these two modes. RESULTS: Of 126 eligible patients, 73 cases were diagnosed with malignant pleural disease. A total of 1292 biopsy specimens from 492 pleural sites were examined for pathological changes. The diagnostic sensitivity, PPV, and NPV of AFI were 99.7%, 58.2%, and 99.2%, respectively. AFI was significantly superior to WLT, which had a sensitivity of 79.7%, PPV of 50.7%, and NPV of 62.8%. Subgroup analysis showed that the AFI type III pattern was significantly more specific for pleural malignant disease than that of WLT. CONCLUSIONS: AFI could further improve the diagnostic efficacy of MT by providing better visualization, convenience, and safety.


Assuntos
Neoplasias , Doenças Pleurais , Derrame Pleural , Humanos , Estudos Prospectivos , Doenças Pleurais/patologia , Pleura/diagnóstico por imagem , Pleura/patologia , Derrame Pleural/etiologia , Toracoscopia , Imagem Óptica/efeitos adversos , Síndrome
7.
Dis Esophagus ; 36(2)2023 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-35849094

RESUMO

Chylothorax is a serious complication after esophagectomy and there are unmet needs for new intraoperative navigation tools to reduce its incidence. The aim of this study is to explore the feasibility and effectiveness of near-infrared fluorescence imaging (NIR-FI) with indocyanine green (ICG) to identify thoracic ducts (TDs) and chyle leakage during video-assisted thoracoscopic esophagectomy. We recruited 41 patients who underwent thoraco-laparoscopic minimally invasive esophagectomy (MIE) for esophageal cancer in this prospective, open-label, single-arm clinical trial. ICG was injected into the right inguinal region before operations, after which TD anatomy and potential chyle leakage were checked under the near-infrared fluorescence intraoperatively. In 38 of 41 patients (92.7%) using NIR-FI, TDs were visible in high contrast. The mean signal-to-background ratio (SBR) value of all fluorescent TDs was 3.05 ± 1.56. Fluorescence imaging of TDs could be detected 0.5 hours after ICG injection and last up to 3 hours with an acceptable SBR value. The optimal observation time window is from about 1 to 2 hours after ICG injection. Under the guidance of real-time NIR-FI, three patients were found to have chylous leakage and the selective TD ligations were performed intraoperatively. No patient had postoperative chylothorax. NIR-FI with ICG can provide highly sensitive and real-time assessment of TDs as well as determine the source of chyle leakage, which might help reduce TD injury and direct selective TD ligation. It could be a promising navigation tool to reduce the incidence of chylothorax after minimally invasive esophagectomy.


Assuntos
Quilotórax , Neoplasias Esofágicas , Humanos , Quilotórax/diagnóstico por imagem , Quilotórax/etiologia , Quilotórax/cirurgia , Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Esofágicas/cirurgia , Neoplasias Esofágicas/complicações , Esofagectomia/efeitos adversos , Esofagectomia/métodos , Verde de Indocianina , Imagem Óptica/efeitos adversos , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Ducto Torácico/diagnóstico por imagem , Ducto Torácico/cirurgia
8.
Transl Vis Sci Technol ; 11(10): 23, 2022 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-36239964

RESUMO

Purpose: The purpose of this study was to investigate quantitative autofluorescence (qAF8) in patients with and without early or intermediate age-related macular degeneration (AMD); to determine the impact of the aged crystalline lens and posterior capsular opacification (PCO). Methods: In phakic and pseudophakic eyes ≥60 years, AMD status was determined by the Beckman system. PCO presence and severity was extracted from clinical records. qAF8 was calculated using custom FIJI plugins. Differences in qAF8, stratified by lens status, PCO severity, and AMD status, were analyzed using generalized estimating equations. Results: In 210 eyes of 115 individuals (mean age = 75.7 ± 6.6 years), qAF8 was lower in intermediate AMD compared to early AMD (P = 0.05). qAF8 did not differ between phakic and pseudophakic eyes (P = 0.8909). In phakic (n = 83) and pseudophakic (n = 127) eyes considered separately, qAF8 did not differ by AMD status (P = 0.0936 and 0.3494, respectively). Qualitative review of qAF images in phakic eyes illustrated high variability. In pseudophakic eyes, qAF8 did not differ with PCO present versus absent (54.5% vs. 45.5%). Review of implanted intraocular lenses (IOLs) revealed that 43.9% were blue-filter IOLs. Conclusions: qAF8 was not associated with AMD status, up to intermediate AMD, considering only pseudophakic eyes to avoid noisy images in phakic eyes. In pseudophakic eyes, qAF8 was not affected by PCO. Because blue-filter IOLs may reduce levels of exciting light for qAF8, future studies investigating qAF in eyes with different IOL types are needed. Translational Relevance: To reduce variability in observational studies and clinical trials requiring qAF8, pseudophakic participants without blue-filter IOLs or advanced PCO should be preferentially enrolled.


Assuntos
Opacificação da Cápsula , Cristalino , Degeneração Macular , Idoso , Idoso de 80 Anos ou mais , Envelhecimento , Opacificação da Cápsula/diagnóstico por imagem , Opacificação da Cápsula/etiologia , Humanos , Degeneração Macular/complicações , Imagem Óptica/efeitos adversos
9.
BMC Gastroenterol ; 22(1): 373, 2022 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-35931985

RESUMO

Revision surgery for the complications after repair of esophageal atresia is often complex because of previous surgeries and chest infections and thus requires surgical expertise. This study describes surgical experiences with the use of indocyanine green (ICG) fluorescence imaging localization-assisted thoracoscopy during revision surgery, including recurrent tracheoesophageal fistula (rTEF) (8 cases, one of which was esophageal-pulmonary fistula) and delayed esophageal closure (1 case). We performed fistula repair and esophageal reconstruction according to the indications of ICG. The application of this method avoids the excessive trauma caused by freeing the trachea and esophagus. Contrast imaging taken one week and one month after surgery indicated no spillover of the contrast agent from the esophagus, except in 1 case. Indocyanine green fluorescence imaging localization-assisted thoracoscopy is worth promoting for revision surgery after esophageal atresia repair.


Assuntos
Atresia Esofágica , Fístula Traqueoesofágica , Atresia Esofágica/complicações , Atresia Esofágica/diagnóstico por imagem , Atresia Esofágica/cirurgia , Humanos , Verde de Indocianina , Imagem Óptica/efeitos adversos , Reoperação/efeitos adversos , Estudos Retrospectivos , Toracoscopia/efeitos adversos , Toracoscopia/métodos , Fístula Traqueoesofágica/diagnóstico por imagem , Fístula Traqueoesofágica/etiologia , Fístula Traqueoesofágica/cirurgia
10.
Front Endocrinol (Lausanne) ; 13: 897797, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35784544

RESUMO

Background and objectives: Accurate identification and evaluation of the parathyroid glands (PGs) intraoperatively is critical to reduce the incidence of postoperative hypoparathyroidism after total thyroidectomy. Near-infrared fluorescence imaging (NIFI), including the autofluorescence (AF) and indocyanine green fluorescence (ICGF) imaging, is a promising technique to protect PGs. This study aimed to assess whether the combined use of AF and ICGF could reduce the incidence of postoperative hypoparathyroidism and improve the identification and evaluation of PGs during total thyroidectomy. Methods: This randomized controlled trial enrolled 180 patients who were randomized into two groups and underwent total thyroidectomy with unilateral or bilateral central lymph node dissection. In the control group, the PGs were identified and evaluated by the naked eye. In the NIFI group, AF was used to identify the PGs and ICGF was applied to assess the blood perfusion of the PGs in situ. The primary outcome was the incidence of postoperative hypoparathyroidism. The secondary outcomes included the number of identified PGs, autotransplanted PGs, and known preserved PGs in situ. Results: The incidence of postoperative transient hypoparathyroidism was significantly lower in the NIFI group than in the control group (27.8% vs. 43.3%, P = 0.029). More PGs were identified in the NIFI group than in the control group (3.6 ± 0.5 vs. 3.2 ± 0.4, P < 0.001). No significant difference was observed in the number of autotransplanted PGs between the two groups (P = 0.134). Compared with the control group, a greater number of known PGs were preserved in situ in the NIFI group (1.3 ± 0.6 vs. 1.0 ± 0.5, P < 0.001). In the NIFI group, only 4.5% of the patients with at least one well-perfused PG (ICG score of 2) developed postoperative hypoparathyroidism, which was significantly lower than that of the control group (34.6%, P < 0.001). Conclusion: Combined use of AF and ICGF during total thyroidectomy reduces the risk of transient postoperative hypoparathyroidism, enhances the ability to identify and preserve PGs, and improves the accuracy of evaluating the perfusion of PGs during surgery. Clinical Trial Registration: Chinese Clinical Trial Register (www.chictr.org.cn), identifier ChiCTR2100045320. Registered on April 12, 2021.


Assuntos
Hipoparatireoidismo , Glândulas Paratireoides , Humanos , Hipoparatireoidismo/diagnóstico , Hipoparatireoidismo/epidemiologia , Hipoparatireoidismo/etiologia , Verde de Indocianina , Imagem Óptica/efeitos adversos , Imagem Óptica/métodos , Glândulas Paratireoides/diagnóstico por imagem , Tireoidectomia/efeitos adversos , Tireoidectomia/métodos
11.
J Invest Surg ; 35(9): 1723-1732, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35786292

RESUMO

OBJECTIVE: This meta-analysis aimed to assess the position of near-infrared autofluorescence (NIRAF) imaging in the recognition and protection of the parathyroid gland (PG) during thyroidectomy. METHODS: The PubMed, MEDLINE, EMBASE, Web of Science, and Cochrane Library databases were searched up to June 2021. The primary outcome was to evaluate the rates of postoperative hypocalcemia, inadvertent PG resection, and autotransplantation of PG when adopting NIRAF imaging compared with standard naked-eye (N-E) surgery. RESULTS: Eight studies with 2,889 patients were enrolled in the analysis. Our analysis showed that the incidence of transient hypocalcemia was 7.11% (60/844) in the NIRAF group and 22.40% (458/2045) in the N-E group (p < 0.0001) and the rate of transient hypoparathyroidism was 28.31% (126/445) and 33.36% (496/1487) in the NIRAF and N-E groups (p = 0.0008). The rate of inadvertent resection of PGs was 7.65% (55/719) in the NIRAF group and 14.39% (132/917) in the N-E group (p < 0.0001). No significant difference was observed in other indexes including the pooled proportion of permanent hypocalcemia and rate of PG autotransplantation. CONCLUSIONS: The application of NIRAF imaging in thyroidectomy can help lower the incidence of inadvertent PG resection and reduce the risk of postoperative hypocalcemia and hypoparathyroidism compared with N-E recognition.


Assuntos
Hipocalcemia , Hipoparatireoidismo , Humanos , Hipocalcemia/epidemiologia , Hipocalcemia/etiologia , Hipocalcemia/prevenção & controle , Hipoparatireoidismo/epidemiologia , Hipoparatireoidismo/etiologia , Hipoparatireoidismo/prevenção & controle , Imagem Óptica/efeitos adversos , Imagem Óptica/métodos , Glândulas Paratireoides/cirurgia , Glândulas Paratireoides/transplante , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Glândula Tireoide/diagnóstico por imagem , Glândula Tireoide/cirurgia , Tireoidectomia/efeitos adversos , Tireoidectomia/métodos
12.
Microcirculation ; 29(6-7): e12768, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35593520

RESUMO

OBJECTIVE: Necrotizing enterocolitis (NEC) is the most prevalent gastrointestinal emergency in premature infants and is characterized by a dysfunctional gut microcirculation. Therefore, there is a dire need for in vivo methods to characterize NEC-induced changes in the structure and function of the gut microcirculation, that is, its vascular phenotype. Since in vivo gut imaging methods are often slow and employ a single-contrast mechanism, we developed a rapid multicontrast imaging technique and a novel analyses pipeline for phenotyping the gut microcirculation. METHODS: Using an experimental NEC model, we acquired in vivo images of the gut microvasculature and blood flow over a 5000 × 7000 µm2 field of view at 5 µm resolution via the following two endogenous contrast mechanisms: intrinsic optical signals and laser speckles. Next, we transformed intestinal images into rectilinear "flat maps," and delineated 1A/V gut microvessels and their perfusion territories as "intestinal vascular units" (IVUs). Employing IVUs, we quantified and visualized NEC-induced changes to the gut vascular phenotype. RESULTS: In vivo imaging required 60-100 s per animal. Relative to the healthy gut, NEC intestines showed a significant overall decrease (i.e. 64-72%) in perfusion, accompanied by vasoconstriction (i.e. 9-12%) and a reduction in perfusion entropy (19%)within sections of the vascular bed. CONCLUSIONS: Multicontrast imaging coupled with IVU-based in vivo vascular phenotyping is a powerful new tool for elucidating NEC pathogenesis.


Assuntos
Enterocolite Necrosante , Humanos , Recém-Nascido , Animais , Enterocolite Necrosante/diagnóstico por imagem , Enterocolite Necrosante/etiologia , Enterocolite Necrosante/patologia , Microvasos , Microcirculação/fisiologia , Recém-Nascido Prematuro , Imagem Óptica/efeitos adversos
13.
Artigo em Chinês | MEDLINE | ID: mdl-35483695

RESUMO

The main causes of hypoparathyroidism are unintentional parathyroidectomy and/or impaired blood supply. Therefore, accurate identification and preservation of parathyroid glands in situ during thyroid or parathyroid surgery has become one of the problems that plague endocrine surgeons. In recent years, near-infrared autofluorescence imaging technology has gradually attracted more and more attention from surgeons because of its simplicity, safety, accuracy, real-time, no-contrast agent, and non-invasiveness. This article reviews the development history, clinical application, and application prospects of the parathyroid gland autofluorescence imaging technology in recent years.


Assuntos
Hipoparatireoidismo , Glândulas Paratireoides , Humanos , Hipoparatireoidismo/etiologia , Hipoparatireoidismo/cirurgia , Imagem Óptica/efeitos adversos , Imagem Óptica/métodos , Glândulas Paratireoides/diagnóstico por imagem , Paratireoidectomia/métodos , Tireoidectomia/métodos
14.
Dis Colon Rectum ; 64(12): 1542-1550, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-33661231

RESUMO

BACKGROUND: Recent studies have clarified that near-infrared observation using indocyanine green has the advantage of evaluating perfusion of the anastomotic site, especially in rectal cancer surgery, resulting in a reduction in anastomotic leak. OBJECTIVE: The aim of this study was to evaluate the efficacy of near-infrared observation for reducing the anastomotic leak after stapled side-to-side anastomosis in colon cancer surgery. DESIGN: This was a retrospective propensity score case-matched study. SETTINGS: The study was conducted at 3 institutions in the Yokohama Clinical Oncology Group. PATIENTS: From January 2011 to December 2019, patients who underwent colon cancer surgery with stapled side-to-side anastomosis were included. MAIN OUTCOME MEASURES: The main outcome was the percentage of anastomotic leak within 30 days after surgery. RESULTS: A total of 1034 patients were collected. There were 532 patients who underwent near-infrared observation and 502 who did not. A total of 370 patients were matched to the near-infrared and non-near-infrared groups. In the near-infrared group, 12 patients (3.2%) were judged to have poor perfusion (4 patients) and no perfusion (8 patients), so the planned transection point was changed. There were no cases of anastomotic leak among these 12 patients. The anastomotic leak rates were 3.5% (13/370) in the non-near-infrared group and 0.8% (3/370) in the near-infrared group. The anastomotic leak and reoperation rates were significantly lower in the near-infrared group than in the non-near-infrared group (OR, 0.224; 95% CI, 0.063-0.794, p = 0.001; OR, 0.348; 95% CI, 0.124-0.977, p = 0.036). LIMITATIONS: Although we reduced selection bias by performing propensity score matching, this was a retrospective study and was not randomized. CONCLUSION: This large-scale case-matched study showed that assessing perfusion by near-infrared observation significantly reduced the anastomotic leak and reoperation rates after stapled side-to-side anastomosis in colon cancer surgery and may be better suited to colo-colonic anastomosis. Video Abstract at http://links.lww.com/DCR/B513.Japanese Clinical Trials Registry: UMIN-CTR000039977. EVALUACIN DEL EFECTO DE LA OBSERVACIN INTRAOPERATORIA CON INFRARROJO CERCANO SOBRE LA FUGA ANASTOMTICA DESPUS DE UNA ANASTOMOSIS LATEROLATERAL CON ENGRAPADORA EN LA CIRUGA DE CNCER DE COLON MEDIANTE EL EMPAREJAMIENTO POR PUNTAJES DE PROPENSIN: ANTECEDENTES:Estudios recientes han aclarado que la observación con infrarrojo cercano con verde de indocianina tiene la ventaja de evaluar la perfusión del sitio anastomótico, especialmente en la cirugía de cáncer de recto, lo que resulta en una reducción de la fuga anastomótica.OBJETIVO:El objetivo de este estudio fue evaluar la eficacia de la observación con infrarrojo cercano para reducir la fuga anastomótica después de una anastomosis latero-lateral con engrapadora en la cirugía de cáncer de colon.DISEÑO:Este fue un estudio retrospectivo emparejado con puntaje de propensión.AJUSTE:El estudio se llevó a cabo en tres instituciones del Grupo de Oncología Clínica de Yokohama.PACIENTES:Desde enero de 2011 hasta diciembre de 2019, se incluyeron pacientes que se sometieron a cirugía de cáncer de colon con anastomosis latero-lateral con engrapadora.PRINCIPALES MEDIDAS DE RESULTADO:El resultado principal fue el porcentaje de fuga anastomótica dentro de los 30 días posteriores a la cirugía.RESULTADOS:Se recogió un total de 1034 pacientes. Hubo 532 pacientes que se sometieron a observación con infrarrojo cercano y 502 que no. Un total de 370 pacientes fueron emparejados con los grupos de infrarrojo cercano y no infrarrojo cercano. En el grupo de infrarrojo cercano, se consideró que 12 casos (3,2%) tenían mala perfusión (4 casos) y ninguna perfusión (8 casos), por lo que se cambió el punto de transección planificado. No hubo casos de fuga anastomótica entre estos 12 casos. Las tasas de fuga anastomótica fueron del 3,5% (13/370) en el grupo sin infrarrojo cercano y del 0,8% (3/370) en el grupo con infrarrojo cercano. Las tasas de fuga anastomótica y de reintervención fueron significativamente menores en el grupo con infrarrojo cercano que en el grupo sin infrarrojo cercano (razón de posibilidades 0,224, intervalo de confianza del 95% 0,063-0,794, p = 0,001; razón de posibilidades 0,348, intervalo de confianza del 95% 0,124 -0,977, p = 0,036, respectivamente).LIMITACIONES:Aunque se redujo el sesgo de selección al realizar el emparejamiento por puntaje de propensión, este fue un estudio retrospectivo y no fue aleatorio.CONCLUSIÓN:Este estudio de casos emparejados a gran escala demostró que la evaluación de la perfusión mediante la observación con infrarrojo cercano redujo significativamente la fuga anastomótica y las tasas de reintervención después de la anastomosis latero-lateral con engrapadora en la cirugía de cáncer de colon y puede ser más adecuada para la anastomosis colo-colónica. Consulte Video Resumen en http://links.lww.com/DCR/B513.Registro japonés de ensayos clínicos: UMIN-CTR000039977.


Assuntos
Anastomose Cirúrgica/efeitos adversos , Fístula Anastomótica/diagnóstico por imagem , Neoplasias do Colo/cirurgia , Imagem Óptica/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Fístula Anastomótica/epidemiologia , Fístula Anastomótica/prevenção & controle , Estudos de Casos e Controles , Feminino , Humanos , Verde de Indocianina/administração & dosagem , Verde de Indocianina/metabolismo , Cuidados Intraoperatórios/instrumentação , Masculino , Imagem Óptica/métodos , Imagem de Perfusão/instrumentação , Pontuação de Propensão , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Suturas/efeitos adversos
15.
J Surg Res ; 259: 39-46, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33279843

RESUMO

BACKGROUND: We previously reported useful methods that can be implemented to identify intersegmental boundary lines (IBLs) by using an intravenous indocyanine green (ICG) fluorescence imaging system (ICG-FS) during a thoracoscopic anatomical segmentectomy (TAS). The aim of this study was to evaluate the recently released third-generation ICG-FS that features an emphasizing xenon-light source for IBL identification. METHODS: We prospectively studied cases involving 106 consecutive patients who underwent TAS. Intraoperatively, we used the third-generation ICG-FS, the conventional ICG methods (CIM) emphasizing xenon-light (CIM-X), and the spectra-A method (SAM) emphasizing xenon-light (SAM-X), for IBL identification. Furthermore, 16 of the 106 patients (15%) could be simultaneously evaluated using old-generation ICG-FSs, CIM, and SAM. All images were completely quantified for illuminance and for three colors, red, green, and blue. RESULTS: IBLs were successfully identified in all the patients (100%) with no adverse events. The SAM-X significantly increased the illuminance, especially in the resecting segments, compared to the CIM (39.0 versus 22.2, P < 0.01) and SAM (39.0 versus 29.3, P < 0.01), with enhanced red color compared to the CIM (33.1 versus 21.9, P < 0.01) and SAM (33.1 versus 14.0, P < 0.01). Furthermore, the SAM-X significantly increased the illuminance contrast compared to the CIM-X (34.1 versus 15.3, P < 0.01). CONCLUSIONS: The present study suggests that the SAM-X potentially provided images with the highest visibility and colorfulness compared to the older generation ICG-FSs or CIM-X. Secure IBL identification can be more easily and safely performed using the SAM-X.


Assuntos
Neoplasias Pulmonares/cirurgia , Pulmão/diagnóstico por imagem , Imagem Óptica/métodos , Pneumonectomia/métodos , Cirurgia Torácica Vídeoassistida/métodos , Administração Intravenosa , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Corantes Fluorescentes/administração & dosagem , Humanos , Verde de Indocianina/administração & dosagem , Luz , Pulmão/irrigação sanguínea , Pulmão/cirurgia , Masculino , Pessoa de Meia-Idade , Imagem Óptica/efeitos adversos , Imagem Óptica/instrumentação , Pneumonectomia/efeitos adversos , Pneumonectomia/instrumentação , Cirurgia Torácica Vídeoassistida/efeitos adversos , Cirurgia Torácica Vídeoassistida/instrumentação , Xenônio
16.
Front Immunol ; 11: 575816, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33123158

RESUMO

Nanotechnology is widely used in the fields of biology and medicine. Some special nanoparticles with good biocompatibility, hydrophilicity, and photostability can be used as ideal systems for biomedical imaging in early diagnosis and treatment of diseases. Among them, aggregation-induced emission materials are new antiaggregation-caused quenching nano-imaging materials, which have advantages in biocompatibility, imaging contrast, and light stability. Meanwhile, heterogeneity of nanoparticles may cause various adverse immune reactions. In response to the above problems, many researchers have modified nano-materials to be multifunctional nano-composites, aiming at combining diagnosis and treatment with simultaneous imaging and targeted therapy and additionally avoiding immune reactions, which is of great potential in imaging-guided therapy. This review discusses the application of aggregation-induced emission materials, and other nano-imaging materials are also mentioned. We hope to provide new ideas and methods for the imaging of nano-materials in diagnosis and treatment.


Assuntos
Corantes Fluorescentes/efeitos adversos , Doenças do Sistema Imunitário/induzido quimicamente , Sistema Imunitário/efeitos dos fármacos , Nanopartículas/efeitos adversos , Imagem Óptica , Nanomedicina Teranóstica , Animais , Humanos , Sistema Imunitário/imunologia , Sistema Imunitário/metabolismo , Doenças do Sistema Imunitário/imunologia , Doenças do Sistema Imunitário/metabolismo , Imagem Óptica/efeitos adversos , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco
17.
Clin Cancer Res ; 26(15): 3990-3998, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32345649

RESUMO

PURPOSE: Incomplete oncologic resections and damage to vital structures during colorectal cancer surgery increases morbidity and mortality. Moreover, neoadjuvant chemoradiotherapy has become the standard treatment modality for locally advanced rectal cancer, where subsequent downstaging can make identification of the primary tumor more challenging during surgery. Near-infrared (NIR) fluorescence imaging can aid surgeons by providing real-time visualization of tumors and vital structures during surgery. EXPERIMENTAL DESIGN: We present the first-in-human clinical experience of a novel NIR fluorescent peptide, cRGD-ZW800-1, for the detection of colon cancer. cRGD-ZW800-1 was engineered to have an overall zwitterionic chemical structure and neutral charge to lower nonspecific uptake and thus background fluorescent signal. We performed a phase I study in 11 healthy volunteer as well as a phase II feasibility study in 12 patients undergoing an elective colon resection, assessing 0.005, 0.015, and 0.05 mg/kg cRGD-ZW800-1 for the intraoperative visualization of colon cancer. RESULTS: cRGD-ZW800-1 appears safe, and exhibited rapid elimination into urine after a single low intravenous dose. Minimal invasive intraoperative visualization of colon cancer through full-thickness bowel wall was possible after an intravenous bolus injection of 0.05 mg/kg at least 2 hours prior to surgery. Longer intervals between injection and imaging improved the tumor-to-background ratio. CONCLUSIONS: cRGD-ZW800-1 enabled fluorescence imaging of colon cancer in both open and minimal invasive surgeries. Further development of cRGD-ZW800-1 for widespread use in cancer surgery may be warranted given the ubiquitous overexpression of various integrins on different types of tumors and their vasculature.


Assuntos
Carcinoma/diagnóstico , Colo/diagnóstico por imagem , Neoplasias do Colo/diagnóstico , Corantes Fluorescentes/administração & dosagem , Imagem Óptica/métodos , Idoso , Idoso de 80 Anos ou mais , Animais , Carcinoma/patologia , Carcinoma/terapia , Quimiorradioterapia Adjuvante , Colectomia/métodos , Colo/patologia , Colo/cirurgia , Neoplasias do Colo/patologia , Neoplasias do Colo/terapia , Estudos de Viabilidade , Feminino , Corantes Fluorescentes/efeitos adversos , Corantes Fluorescentes/química , Corantes Fluorescentes/farmacocinética , Voluntários Saudáveis , Humanos , Integrinas/metabolismo , Masculino , Camundongos , Pessoa de Meia-Idade , Terapia Neoadjuvante , Imagem Óptica/efeitos adversos , Peptídeos Cíclicos/administração & dosagem , Peptídeos Cíclicos/efeitos adversos , Peptídeos Cíclicos/química , Peptídeos Cíclicos/farmacocinética , Compostos de Amônio Quaternário/administração & dosagem , Compostos de Amônio Quaternário/efeitos adversos , Compostos de Amônio Quaternário/química , Compostos de Amônio Quaternário/farmacocinética , Ratos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Ácidos Sulfônicos/administração & dosagem , Ácidos Sulfônicos/efeitos adversos , Ácidos Sulfônicos/química , Ácidos Sulfônicos/farmacocinética , Testes de Toxicidade Aguda
18.
BMC Cancer ; 19(1): 939, 2019 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-31604469

RESUMO

BACKGROUND: This preliminary study aimed to examine the feasibility of sentinel lymph node biopsy (SLNB) using contrast-enhanced ultrasound (CEUS) vs. indocyanine green fluorescence (ICG), combined with blue dye in patients with breast cancer. METHODS: This was a retrospective study of consecutive female patients with invasive stage I-III (based on pre-operative physical examination and imaging) primary breast cancer at the Peking Union Medical College Hospital between 01/2013 and 01/2015 who underwent preoperative SLNB by ICG + blue dye or CEUS + blue dye. The numbers of detected SLNs, detection rates, and recurrence-free survival (RFS) rates were compared between the two groups. RESULTS: A total of 443 patients were included. The detection rates of SLNs in the CEUS + blue dye and ICG + blue dye groups were 98.4 and 98.1%, respectively (P = 0.814). The average numbers of SLNs detected per patient showed no significant difference between the two groups (3.06 ± 1.33 and 3.12 ± 1.31 in the CEUS + blue dye and ICG + blue dye groups, respectively; P = 0.659). After a median follow-up of 46 months, five patients in the CEUS + blue dye group and 15 in the ICG + blue dye group had recurrence. RFS rates showed no significant difference (P = 0.55). CONCLUSION: This preliminary study suggests that CEUS + blue dye and ICG + blue dye are both feasible for SLN detection in breast cancer.


Assuntos
Neoplasias da Mama/patologia , Corantes , Verde de Indocianina , Metástase Linfática/diagnóstico por imagem , Azul de Metileno , Imagem Óptica/métodos , Biópsia de Linfonodo Sentinela/métodos , Ultrassonografia Mamária/métodos , Adulto , Idoso , Axila , Intervalo Livre de Doença , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Imagem Óptica/efeitos adversos , Estudos Retrospectivos , Linfonodo Sentinela/patologia , Ultrassonografia Mamária/efeitos adversos
19.
Breast Cancer ; 26(1): 1-10, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29961238

RESUMO

In the past decades, breast surgeons have changed the clinical practice in the surgical treatment of breast cancer, by performing sentinel lymph node biopsy (SLNB) instead of performing axillary lymph node dissection (ALND) in axillary lymph node clinically negative breast cancer patients. ALND can also be avoided in SLN-positive patients who meet the Z-0011 criteria. However, the postoperative complications of SLNB and ALND, such as the secondary upper extremity lymphedema, are common and need effective solutions to prevent as soon as possible. The axillary reverse mapping (ARM) technique has been developed to map and preserve arm lymphatic drainage during ALND and/or SLNB, thereby minimizing arm lymphedema. However, the success of ARM in reducing lymphedema has not been exactly determined. If ARM can be confirmed to be both effective and oncologically safe in preventing lymphedema, this technique should be recommended in the management of breast cancer treatment.


Assuntos
Neoplasias da Mama/cirurgia , Metástase Linfática/diagnóstico por imagem , Linfedema/prevenção & controle , Imagem Óptica/métodos , Complicações Pós-Operatórias/prevenção & controle , Axila , Neoplasias da Mama/patologia , Meios de Contraste/administração & dosagem , Meios de Contraste/efeitos adversos , Feminino , Humanos , Excisão de Linfonodo/efeitos adversos , Excisão de Linfonodo/métodos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Metástase Linfática/patologia , Vasos Linfáticos/diagnóstico por imagem , Vasos Linfáticos/patologia , Linfedema/etiologia , Mastectomia/efeitos adversos , Mastectomia/métodos , Oncologia/métodos , Imagem Óptica/efeitos adversos , Tratamentos com Preservação do Órgão/efeitos adversos , Tratamentos com Preservação do Órgão/métodos , Complicações Pós-Operatórias/etiologia , Biópsia de Linfonodo Sentinela/efeitos adversos , Biópsia de Linfonodo Sentinela/métodos
20.
Eur Urol ; 75(3): 492-497, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30553615

RESUMO

BACKGROUND: With the increasing adoption of novel technologies and anatomical techniques, surgical management of benign prostatic hyperplasia (BPH) provides significant benefits in terms of obstruction relief, early urethral catheter removal, and faster return to daily activities. However, the main pitfall of BPH surgery in sexually active men remains ejaculatory dysfunction (EjD), which permanently affects quality of life. OBJECTIVE: To detail a novel technique for marking the intraprostatic urethra through a retrograde injection of indocyanine green to enhance selective dissection of prostatic lobes during urethra-sparing robot-assisted simple prostatectomy (US-RASP) with the use of near-infrared fluorescence imaging (NIFI). DESIGN, SETTING, AND PARTICIPANTS: Between January and September 2017, 12 consecutive male patients, who had BPH, were sexually active, and were motivated to preserve ejaculatory function, underwent US-RASP. SURGICAL PROCEDURE: US-RASP with NIFI to enhance the identification and preservation of the prostatic urethra. MEASUREMENTS: Clinical data were prospectively collected in our institutional RASP dataset. Perioperative and functional outcomes of US-RASP were both graded, and assessed according to Clavien grading system and validated questionnaires postoperatively (International Prostate Symptom Score [IPSS]; Male Sexual Health Questionnaire on EjD [MSHQ-EjD] Short Form) at 3 and 12mo. RESULTS AND LIMITATIONS: Median preoperative prostate size was 102cc (interquartile range [IQR] 88-115). Median operative time was 150min (IQR 145-170). Median estimated blood loss was 250 (IQR 200-350). Continuous bladder irrigation was avoided in 83.4% of patients. Median time to catheter removal was 7d (IQR 7-7) with a median hospital stay of 3d (IQR 2-3). At 1-yr follow-up, median IPSS score, International Index of Erectile Function score, and MSHQ-EjD Short Form score were 5 (IQR 4-8), 26 (IQR 26-28), and 12 (IQR 1-14), respectively. Satisfactory anterograde ejaculation was reported in eight patients (66%). CONCLUSIONS: We described a novel NIFI-guided technique to perform US-RASP. This technique showed promising early functional results, suggesting a significant role of intraprostatic urethral integrity for the preservation of ejaculatory function. PATIENT SUMMARY: We developed a novel robotic technique to perform simple prostatectomy with integral preservation of the prostatic urethra. This technique provided a high rate of ejaculatory function preservation.


Assuntos
Ejaculação , Corantes Fluorescentes/administração & dosagem , Verde de Indocianina/administração & dosagem , Imagem Óptica/métodos , Prostatectomia/métodos , Hiperplasia Prostática/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Uretra/cirurgia , Humanos , Tempo de Internação , Masculino , Imagem Óptica/efeitos adversos , Tratamentos com Preservação do Órgão , Prostatectomia/efeitos adversos , Hiperplasia Prostática/diagnóstico , Hiperplasia Prostática/fisiopatologia , Qualidade de Vida , Recuperação de Função Fisiológica , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Comportamento Sexual , Disfunções Sexuais Fisiológicas/etiologia , Disfunções Sexuais Fisiológicas/fisiopatologia , Disfunções Sexuais Fisiológicas/prevenção & controle , Fatores de Tempo , Resultado do Tratamento , Uretra/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...