Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.271
Filtrar
1.
Pediatr Surg Int ; 40(1): 125, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38714568

RESUMO

BACKGROUND: Postoperative pulmonary growth in congenital diaphragmatic hernias (CDH) remains unclear. We investigated postoperative pulmonary vascular growth using serial lung perfusion scintigraphy in patients with CDH. METHODS: Neonates with left CDH who underwent surgery and postoperative lung perfusion scintigraphy at our institution between 2001 and 2020 were included. Patient demographics, clinical courses, and lung scintigraphy data were retrospectively analyzed by reviewing medical records. RESULTS: Twenty-one patients with CDH were included. Of these, 10 underwent serial lung scintigraphy. The ipsilateral perfusion rate and median age on the 1st and serial lung scintigraphy were 32% (34 days) and 33% (3.6 years), respectively. Gestational age at prenatal diagnosis (p = 0.02), alveolar-arterial oxygen difference (A-aDO2) at birth (p = 0.007), and preoperative nitric oxide (NO) use (p = 0.014) significantly correlated with the 1st lung scintigraphy. No other variables, including operative approach, were significantly correlated with the 1st or serial scintigraphy findings. All patients improved lung perfusion with serial studies [Difference: + 7.0 (4.3-13.25) %, p = 0.001, paired t-test]. This improvement was not significantly correlated with preoperative A-aDO2 (p = 0.96), NO use (p = 0.28), or liver up (p = 0.90). The difference was significantly larger in patients who underwent thoracoscopic repair than in those who underwent open abdominal repair [+ 10.6 (5.0-17.1) % vs. + 4.25 (1.2-7.9) %, p = 0.042]. CONCLUSION: Our study indicated a postoperative improvement in ipsilateral lung vascular growth, which is possibly enhanced by a minimally invasive approach, in patients with CDH.


Assuntos
Hérnias Diafragmáticas Congênitas , Pulmão , Humanos , Hérnias Diafragmáticas Congênitas/cirurgia , Hérnias Diafragmáticas Congênitas/diagnóstico por imagem , Estudos Retrospectivos , Feminino , Masculino , Recém-Nascido , Pulmão/diagnóstico por imagem , Pulmão/irrigação sanguínea , Período Pós-Operatório , Imagem de Perfusão/métodos , Pré-Escolar
2.
J Appl Clin Med Phys ; 25(5): e14368, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38657114

RESUMO

OBJECTIVE: Alzheimer's disease, an irreversible neurological condition, demands timely diagnosis for effective clinical intervention. This study employs radiomics analysis to assess image features in default mode network cerebral perfusion imaging among individuals with cognitive impairment. METHODS: A radiomics analysis of cerebral perfusion imaging was conducted on 117 patients with cognitive impairment. They were divided into training and validation sets in a 7:3 ratio. Least Absolute Shrinkage and Selection Operator (LASSO) and Random Forest were employed to select and model image features, followed by logistic regression analysis of LASSO and Random Forest results. Diagnostic performance was assessed by calculating the area under the curve (AUC). RESULTS: In the training set, LASSO achieved AUC of 0.978, Random Forest had an AUC of 0.933. In the validation set, LASSO had AUC of 0.859, Random Forest had AUC of 0.986. By conducting Logistic Regression analysis in combination with LASSO and Random Forest, we identified a total of five radiomics features, with four related to morphology and one to textural features, originating from the medial prefrontal cortex and middle temporal gyrus. In the training set, Logistic Regression achieved AUC of 0.911, while in the validation set, it attained AUC of 0.925. CONCLUSION: The medial prefrontal cortex and middle temporal gyrus are the two brain regions within the default mode network that hold the highest significance for Alzheimer's disease diagnosis. Radiomics analysis contributes to the clinical assessment of Alzheimer's disease by delving into image data to extract deeper layers of information.


Assuntos
Doença de Alzheimer , Imagem de Perfusão , Humanos , Doença de Alzheimer/diagnóstico por imagem , Feminino , Masculino , Idoso , Imagem de Perfusão/métodos , Processamento de Imagem Assistida por Computador/métodos , Circulação Cerebrovascular/fisiologia , Pessoa de Meia-Idade , Disfunção Cognitiva/diagnóstico por imagem , Idoso de 80 Anos ou mais , Imageamento por Ressonância Magnética/métodos , Prognóstico , Radiômica
3.
Neurosurg Rev ; 47(1): 182, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38649539

RESUMO

BACKGROUND: Endovascular treatment (EVT) is effective for large vessel occlusion (LVO) stroke with smaller volumes of CT perfusion (CTP)-defined core. However, the influence of perfusion imaging during thrombectomy on the functional outcomes of patients with large ischemic core (LIC) stroke at both early and late time windows is uncertain in real-world practice. METHOD: A retrospective analysis was performed on 99 patients who underwent computed tomography angiography (CTA) and CT perfusion (CTP)-Rapid Processing of Perfusion and Diffusion (RAPID) before EVT and had a baseline ischemic core ≥ 50 mL and/or Alberta Stroke Program Early CT Score (ASPECTS) score of 0-5. The primary outcome was the three-month modified Rankin Scale (mRS) score. Data were analyzed by binary logistic regression and receiver operating characteristic (ROC) curves. RESULTS: A fair outcome (mRS, 0-3) was found in 34 of the 99 patients while 65 had a poor prognosis (mRS, 4-6). The multivariate logistic regression analysis showed that onset-to-reperfusion (OTR) time (odds ratio [OR], 1.004; 95% confidence interval [CI], 1.001-1.007; p = 0.008), ischemic core (OR, 1.066; 95% CI, 1.024-1.111; p = 0.008), and the hypoperfusion intensity ratio (HIR) (OR, 70.898; 95% CI, 1.130-4450.152; p = 0.044) were independent predictors of outcome. The combined results of ischemic core, HIR, and OTR time showed good performance with an area under the ROC curve (AUC) of 0.937, significantly higher than the individual variables (p < 0.05) using DeLong's test. CONCLUSIONS: Higher HIR and longer OTR time in large core stroke patients were independently associated with unfavorable three-month outcomes after EVT.


Assuntos
Procedimentos Endovasculares , AVC Isquêmico , Trombectomia , Humanos , Masculino , Feminino , Idoso , Procedimentos Endovasculares/métodos , AVC Isquêmico/cirurgia , Pessoa de Meia-Idade , Resultado do Tratamento , Estudos Retrospectivos , Trombectomia/métodos , Idoso de 80 Anos ou mais , Reperfusão/métodos , Isquemia Encefálica/cirurgia , Acidente Vascular Cerebral/cirurgia , Imagem de Perfusão , Angiografia por Tomografia Computadorizada
4.
Nitric Oxide ; 147: 6-12, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38588918

RESUMO

Acute respiratory distress syndrome (ARDS) is characterized by a redistribution of regional lung perfusion that impairs gas exchange. While speculative, experimental evidence suggests that perfusion redistribution may contribute to regional inflammation and modify disease progression. Unfortunately, tools to visualize and quantify lung perfusion in patients with ARDS are lacking. This review explores recent advances in perfusion imaging techniques that aim to understand the pulmonary circulation in ARDS. Dynamic contrast-enhanced computed tomography captures first-pass kinetics of intravenously injected dye during continuous scan acquisitions. Different contrast characteristics and kinetic modeling have improved its topographic measurement of pulmonary perfusion with high spatial and temporal resolution. Dual-energy computed tomography can map the pulmonary blood volume of the whole lung with limited radiation exposure, enabling its application in clinical research. Electrical impedance tomography can obtain serial topographic assessments of perfusion at the bedside in response to treatments such as inhaled nitric oxide and prone position. Ongoing technological improvements and emerging techniques will enhance lung perfusion imaging and aid its incorporation into the care of patients with ARDS.


Assuntos
Pulmão , Síndrome do Desconforto Respiratório , Humanos , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Síndrome do Desconforto Respiratório/fisiopatologia , Pulmão/diagnóstico por imagem , Pulmão/irrigação sanguínea , Tomografia Computadorizada por Raios X , Circulação Pulmonar , Imagem de Perfusão/métodos , Animais
5.
J Integr Neurosci ; 23(4): 70, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38682213

RESUMO

Alzheimer's disease (AD) is the leading cause of dementia worldwide and significantly impacts the essential functions of daily life and social activities. Research on AD has found that its pathogenesis is related to the extracellular accumulation of amyloid-beta (Aß) plaques and intracellular neurofibrillary tangles in the cortical and limbic areas of the human brain, as well as cerebrovascular factors. The detection of Aß or tau can be performed using various probes and methodologies. However, these modalities are expensive to implement and often require invasive procedures, limiting accessibility on a large scale. While magnetic resonance imaging (MRI) and computed tomography (CT) are generally used for morphological and structural brain imaging, they show wide variability in their accuracy for the clinical diagnosis of AD. Several novel imaging modalities have emerged as alternatives that can accurately and vividly display the changes in blood flow and metabolism in each brain area and enable physicians and researchers to gain insights into the generation and progression of the cerebro-microvascular pathologies of AD. In this review, we summarize the current knowledge on microvascular perfusion imaging modalities and their application in AD, including MRI (dynamic susceptibility contrast-MRI, arterial spin labeling-MRI), CT (cerebral CT perfusion imaging), emission computed tomography (positron emission tomography (PET), single-photon emission computed tomography (SPECT)), transcranial doppler ultrasonography (TCD), and retinal microvascular imaging (optical coherence tomography imaging, computer-assisted methods for evaluating retinal vasculature).


Assuntos
Doença de Alzheimer , Imagem de Perfusão , Humanos , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/metabolismo , Imagem de Perfusão/métodos , Circulação Cerebrovascular/fisiologia , Microvasos/diagnóstico por imagem , Encéfalo/diagnóstico por imagem
6.
Neuroradiology ; 66(5): 749-759, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38498208

RESUMO

PURPOSE: CT perfusion of the brain is a powerful tool in stroke imaging, though the radiation dose is rather high. Several strategies for dose reduction have been proposed, including increasing the intervals between the dynamic scans. We determined the impact of temporal resolution on perfusion metrics, therapy decision, and radiation dose reduction in brain CT perfusion from a large dataset of patients with suspected stroke. METHODS: We retrospectively included 3555 perfusion scans from our clinical routine dataset. All cases were processed using the perfusion software VEOcore with a standard sampling of 1.5 s, as well as simulated reduced temporal resolution of 3.0, 4.5, and 6.0 s by leaving out respective time points. The resulting perfusion maps and calculated volumes of infarct core and mismatch were compared quantitatively. Finally, hypothetical decisions for mechanical thrombectomy following the DEFUSE-3 criteria were compared. RESULTS: The agreement between calculated volumes for core (ICC = 0.99, 0.99, and 0.98) and hypoperfusion (ICC = 0.99, 0.99, and 0.97) was excellent for all temporal sampling schemes. Of the 1226 cases with vascular occlusion, 14 (1%) for 3.0 s sampling, 23 (2%) for 4.5 s sampling, and 63 (5%) for 6.0 s sampling would have been treated differently if the DEFUSE-3 criteria had been applied. Reduction of temporal resolution to 3.0 s, 4.5 s, and 6.0 s reduced the radiation dose by a factor of 2, 3, or 4. CONCLUSION: Reducing the temporal sampling of brain perfusion CT has only a minor impact on image quality and treatment decision, but significantly reduces the radiation dose to that of standard non-contrast CT.


Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral , Humanos , Estudos Retrospectivos , Redução da Medicação , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/terapia , Encéfalo/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Tomografia Computadorizada por Raios X/métodos , Isquemia Encefálica/terapia , Perfusão , Imagem de Perfusão/métodos
7.
Radiologie (Heidelb) ; 64(4): 321-332, 2024 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-38502373

RESUMO

Radiology plays a key role in the diagnosis and monitoring of hepatocellular carcinoma (HCC). Ultrasound, computed tomography (CT) and magnetic resonance imaging (MRI) are used to identify HCC lesions. Multiparametric MRI provides detailed insights into the tumor biology through the analysis of morphology, perfusion and diffusion. In this way preoperative decisions can be optimized. The guidelines recommend using contrast-enhanced MRI or ultrasound for the diagnosis of HCC. The preferred method is MRI due to its superiority in the detection of small lesions The treatment response is evaluated using modified response evaluation criteria for solid tumors (RECIST) and the European Association for the Study of the Liver (EASL) criteria. The use of multiparametric MRI in conjunction with the liver imaging reporting and data system (LI-RADS) plays overall a central role in the precise diagnosis and monitoring of the treatment of HCC.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Imageamento por Ressonância Magnética Multiparamétrica , Humanos , Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/cirurgia , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Perfusão , Imagem de Perfusão
8.
Comput Med Imaging Graph ; 114: 102376, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38537536

RESUMO

Acute ischemic stroke is a critical health condition that requires timely intervention. Following admission, clinicians typically use perfusion imaging to facilitate treatment decision-making. While deep learning models leveraging perfusion data have demonstrated the ability to predict post-treatment tissue infarction for individual patients, predictions are often represented as binary or probabilistic masks that are not straightforward to interpret or easy to obtain. Moreover, these models typically rely on large amounts of subjectively segmented data and non-standard perfusion analysis techniques. To address these challenges, we propose a novel deep learning approach that directly predicts follow-up computed tomography images from full spatio-temporal 4D perfusion scans through a temporal compression. The results show that this method leads to realistic follow-up image predictions containing the infarcted tissue outcomes. The proposed compression method achieves comparable prediction results to using perfusion maps as inputs but without the need for perfusion analysis or arterial input function selection. Additionally, separate models trained on 45 patients treated with thrombolysis and 102 treated with thrombectomy showed that each model correctly captured the different patient-specific treatment effects as shown by image difference maps. The findings of this work clearly highlight the potential of our method to provide interpretable stroke treatment decision support without requiring manual annotations.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , AVC Isquêmico/diagnóstico por imagem , AVC Isquêmico/terapia , Tomografia Computadorizada Quadridimensional , Isquemia Encefálica/diagnóstico por imagem , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/terapia , Imagem de Perfusão/métodos , Perfusão
10.
J Stroke Cerebrovasc Dis ; 33(6): 107677, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38460777

RESUMO

OBJECTIVES: To investigate the relationship between baseline computed tomography perfusion deficit volumes and functional outcomes in patients with basilar artery occlusion (BAO) undergoing endovascular therapy. METHODS: This was a single-center study in which the data of 64 patients with BAO who underwent endovascular therapy were retrospectively analyzed. All the patients underwent multi-model computed tomography on admission. The posterior-circulation Acute Stroke Prognosis Early Computed Tomography Score was applied to assess the ischemic changes. Perfusion deficit volumes were obtained using Syngo.via software. The primary outcome of the analysis was a good functional outcome (90-day modified Rankin Scale score ≤ 3). Logistic regression and receiver operating characteristic curves were used to explore predictors of functional outcome. RESULTS: A total of 64 patients (median age, 68 years; 72 % male) were recruited, of whom 26 (41 %) patients achieved good functional outcomes, while 38 (59 %) had poor functional outcomes. Tmax > 10 s, Tmax > 6 s, and rCBF < 30 % volume were independent predictors of good functional outcomes (odds ratio range, 1.0-1.2; 95 % confidence interval [CI], 1.0-1.4]) and performed well in the receiver operating characteristic curve analyses, exhibiting positive prognostic value; the areas under the curve values were 0.85 (95 % CI, 0.75-0.94), 0.81 (95 % CI, 0.70-0.90), and 0.78 (95 % CI, 0.67-0.89). CONCLUSION: Computed tomography perfusion deficit volume represents a valuable tool in predicting high risk of disability and mortality in patients with BAO after endovascular treatment.


Assuntos
Circulação Cerebrovascular , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares , Estado Funcional , Imagem de Perfusão , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Insuficiência Vertebrobasilar , Humanos , Masculino , Feminino , Idoso , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Pessoa de Meia-Idade , Resultado do Tratamento , Insuficiência Vertebrobasilar/diagnóstico por imagem , Insuficiência Vertebrobasilar/fisiopatologia , Insuficiência Vertebrobasilar/terapia , Imagem de Perfusão/métodos , Avaliação da Deficiência , Idoso de 80 Anos ou mais , Fatores de Tempo , Angiografia Cerebral , Fatores de Risco , Artéria Basilar/diagnóstico por imagem , Artéria Basilar/fisiopatologia , Tomografia Computadorizada Multidetectores , Curva ROC
11.
AJNR Am J Neuroradiol ; 45(3): 277-283, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38302197

RESUMO

BACKGROUND AND PURPOSE: The established global threshold of rCBF <30% for infarct core segmentation can lead to false-positives, as it does not account for the differences in blood flow between GM and WM and patient-individual factors, such as microangiopathy. To mitigate this problem, we suggest normalizing each voxel not only with a global reference value (ie, the median value of normally perfused tissue) but also with its local contralateral counterpart. MATERIALS AND METHODS: We retrospectively enrolled 2830 CTP scans with suspected ischemic stroke, of which 335 showed obvious signs of microangiopathy. In addition to the conventional, global normalization, a local normalization was performed by dividing the rCBF maps with their mirrored and smoothed counterpart, which sets each voxel value in relation to the contralateral counterpart, intrinsically accounting for GM and WM differences and symmetric patient individual microangiopathy. Maps were visually assessed and core volumes were calculated for both methods. RESULTS: Cases with obvious microangiopathy showed a strong reduction in false-positives by using local normalization (mean 14.7 mL versus mean 3.7 mL in cases with and without microangiopathy). On average, core volumes were slightly smaller, indicating an improved segmentation that was more robust against naturally low blood flow values in the deep WM. CONCLUSIONS: The proposed method of local normalization can reduce overestimation of the infarct core, especially in the deep WM and in cases with obvious microangiopathy. False-positives in CTP infarct core segmentation might lead to less-than-optimal therapy decisions when not correctly interpreted. The proposed method might help mitigate this problem.


Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral , Humanos , Isquemia Encefálica/terapia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Infarto , Circulação Cerebrovascular , Perfusão , Imagem de Perfusão/métodos
12.
Abdom Radiol (NY) ; 49(4): 1084-1091, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38416165

RESUMO

PURPOSE: To determine if hepatic and splenic perfusion parameters are useful in identifying severe portal hypertension (SPH). METHODS: The study enrolled 52 patients who underwent perfusion CT scan within one week before the hepatic venous pressure gradient (HVPG) measurement. A commercial software package was used for post-processing to generate hepatic and splenic perfusion parameters. Correlations were assessed using Pearson and Spearman rank correlation coefficients. Logistic regression was used to screen predictive parameters of SPH. The cut-off values of parameters for severe portal hypertension were calculated, as well as the sensitivity and specificity. RESULTS: There was a significant difference between SPH and non-severe portal hypertension (NSPH) in blood volume of liver (BVLiver), hepatic arterial fraction (HAF), hepatic arterial perfusion (HAP), portal venous perfusion (PVP), mean slope of increase in spleen (MSISpleen), BVSpleen, blood flow of spleen (BFSpleen), BVSpleen/Liver, and BVSpleen/Liver(P) (p < 0.05). The Spearman correlation coefficient was - 0.541 (p < 0.001) between BVSpleen/Live and HVPG and - 0.568 (p < 0.001) between BVSpleen/Liver(P) and HVPG. Using a BVSpleen/Liver value of 0.780 or BVSpleen/Liver(P) value of 1.061 as the cut-off value for the detection of SPH, the sensitivity and specificity were 94.7% and 72.7%, 100%, and 63.6% respectively. CONCLUSION: There was a moderate correlation between CT perfusion parameters BVSpleen/Liver, BVSpleen/Liver(P), and HVPG, which may be used to detect severe portal hypertension.


Assuntos
Hipertensão Portal , Baço , Humanos , Baço/diagnóstico por imagem , Baço/irrigação sanguínea , Cirrose Hepática , Fígado/irrigação sanguínea , Hipertensão Portal/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Imagem de Perfusão
13.
Clin Radiol ; 79(5): e736-e743, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38341343

RESUMO

AIM: To evaluate whole-node histogram parameters of blood flow (BF) maps derived from three-dimensional pseudo-continuous arterial spin-labelled (3D pCASL) imaging in discriminating metastatic from benign upper cervical lymph nodes (UCLNs) for nasopharyngeal carcinoma (NPC) patients. MATERIALS AND METHODS: Eighty NPC patients with a total of 170 histologically confirmed UCLNs (67 benign and 103 metastatic) were included retrospectively. Pre-treatment 3D pCASL imaging was performed and whole-node histogram analysis was then applied. Histogram parameters and morphological features, such as minimum axis diameter (MinAD), maximum axis diameter (MaxAD), and location of UCLNs, were assessed and compared between benign and metastatic lesions. Predictors were identified and further applied to establish a combined model by multivariate logistic regression in predicting the probability of metastatic UCLNs. Receiver operating characteristic (ROC) curves were used to analyse the diagnostic performance. RESULTS: Metastatic UCLNs had larger MinAD and MinAD/MaxAD ratio, greater energy and entropy values, and higher incidence of level II (upper jugular group), but lower BF10th value than benign nodes (all p<0.05). MinAD, BF10th, energy, and entropy were validated as independent predictors in diagnosing metastatic UCLNs. The combined model yielded an area under the curve (AUC) of 0.932, accuracy of 84.42 %, sensitivity of 80.6 %, and specificity of 90.29 %. CONCLUSIONS: Whole-node histogram analysis on BF maps is a feasible tool to differentiate metastatic from benign UCLNs in NPC patients, and the combined model can further improve the diagnostic efficacy.


Assuntos
Neoplasias Nasofaríngeas , Humanos , Carcinoma Nasofaríngeo/diagnóstico por imagem , Carcinoma Nasofaríngeo/patologia , Metástase Linfática/diagnóstico por imagem , Metástase Linfática/patologia , Estudos Retrospectivos , Neoplasias Nasofaríngeas/patologia , Imagem de Perfusão , Linfonodos/diagnóstico por imagem , Linfonodos/patologia
14.
NMR Biomed ; 37(6): e5115, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38355219

RESUMO

Arterial spin labeling (ASL) has been widely used to evaluate arterial blood and perfusion dynamics, particularly in the brain, but its application to the spinal cord has been limited. The purpose of this study was to optimize vessel-selective pseudocontinuous arterial spin labeling (pCASL) for angiographic and perfusion imaging of the rat cervical spinal cord. A pCASL preparation module was combined with a train of gradient echoes for dynamic angiography. The effects of the echo train flip angle, label duration, and a Cartesian or radial readout were compared to examine their effects on visualizing the segmental arteries and anterior spinal artery (ASA) that supply the spinal cord. Lastly, vessel-selective encoding with either vessel-encoded pCASL (VE-pCASL) or super-selective pCASL (SS-pCASL) were compared. Vascular territory maps were obtained with VE-pCASL perfusion imaging of the spinal cord, and the interanimal variability was evaluated. The results demonstrated that longer label durations (200 ms) resulted in greater signal-to-noise ratio in the vertebral arteries, improved the conspicuity of the ASA, and produced better quality maps of blood arrival times. Cartesian and radial readouts demonstrated similar image quality. Both VE-pCASL and SS-pCASL adequately labeled the right or left vertebral arteries, which revealed the interanimal variability in the segmental artery with variations in their location, number, and laterality. VE-pCASL also demonstrated unique interanimal variations in spinal cord perfusion with a right-sided dominance across the six animals. Vessel-selective pCASL successfully achieved visualization of the arterial inflow dynamics and corresponding perfusion territories of the spinal cord. These methodological developments provide unique insights into the interanimal variations in the arterial anatomy and dynamics of spinal cord perfusion.


Assuntos
Angiografia por Ressonância Magnética , Ratos Sprague-Dawley , Animais , Masculino , Angiografia por Ressonância Magnética/métodos , Imagem de Perfusão/métodos , Marcadores de Spin , Ratos , Medula Cervical/diagnóstico por imagem , Medula Cervical/irrigação sanguínea , Medula Espinal/irrigação sanguínea , Medula Espinal/diagnóstico por imagem
15.
N Engl J Med ; 390(8): 701-711, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38329148

RESUMO

BACKGROUND: Thrombolytic agents, including tenecteplase, are generally used within 4.5 hours after the onset of stroke symptoms. Information on whether tenecteplase confers benefit beyond 4.5 hours is limited. METHODS: We conducted a multicenter, double-blind, randomized, placebo-controlled trial involving patients with ischemic stroke to compare tenecteplase (0.25 mg per kilogram of body weight, up to 25 mg) with placebo administered 4.5 to 24 hours after the time that the patient was last known to be well. Patients had to have evidence of occlusion of the middle cerebral artery or internal carotid artery and salvageable tissue as determined on perfusion imaging. The primary outcome was the ordinal score on the modified Rankin scale (range, 0 to 6, with higher scores indicating greater disability and a score of 6 indicating death) at day 90. Safety outcomes included death and symptomatic intracranial hemorrhage. RESULTS: The trial enrolled 458 patients, 77.3% of whom subsequently underwent thrombectomy; 228 patients were assigned to receive tenecteplase, and 230 to receive placebo. The median time between the time the patient was last known to be well and randomization was approximately 12 hours in the tenecteplase group and approximately 13 hours in the placebo group. The median score on the modified Rankin scale at 90 days was 3 in each group. The adjusted common odds ratio for the distribution of scores on the modified Rankin scale at 90 days for tenecteplase as compared with placebo was 1.13 (95% confidence interval, 0.82 to 1.57; P = 0.45). In the safety population, mortality at 90 days was 19.7% in the tenecteplase group and 18.2% in the placebo group, and the incidence of symptomatic intracranial hemorrhage was 3.2% and 2.3%, respectively. CONCLUSIONS: Tenecteplase therapy that was initiated 4.5 to 24 hours after stroke onset in patients with occlusions of the middle cerebral artery or internal carotid artery, most of whom had undergone endovascular thrombectomy, did not result in better clinical outcomes than those with placebo. The incidence of symptomatic intracerebral hemorrhage was similar in the two groups. (Funded by Genentech; TIMELESS ClinicalTrials.gov number, NCT03785678.).


Assuntos
Isquemia Encefálica , AVC Isquêmico , Imagem de Perfusão , Tenecteplase , Trombectomia , Ativador de Plasminogênio Tecidual , Humanos , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/tratamento farmacológico , Isquemia Encefálica/mortalidade , Isquemia Encefálica/cirurgia , Fibrinolíticos/administração & dosagem , Fibrinolíticos/efeitos adversos , Fibrinolíticos/uso terapêutico , Hemorragias Intracranianas/induzido quimicamente , Hemorragias Intracranianas/diagnóstico por imagem , Perfusão , Imagem de Perfusão/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/tratamento farmacológico , Acidente Vascular Cerebral/mortalidade , Acidente Vascular Cerebral/cirurgia , Tenecteplase/administração & dosagem , Tenecteplase/efeitos adversos , Tenecteplase/uso terapêutico , Trombectomia/efeitos adversos , Trombectomia/métodos , Ativador de Plasminogênio Tecidual/administração & dosagem , Ativador de Plasminogênio Tecidual/efeitos adversos , Ativador de Plasminogênio Tecidual/uso terapêutico , Resultado do Tratamento , Método Duplo-Cego , AVC Isquêmico/diagnóstico por imagem , AVC Isquêmico/tratamento farmacológico , AVC Isquêmico/mortalidade , AVC Isquêmico/cirurgia , Infarto da Artéria Cerebral Média/diagnóstico por imagem , Infarto da Artéria Cerebral Média/tratamento farmacológico , Infarto da Artéria Cerebral Média/cirurgia , Doenças das Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/tratamento farmacológico , Doenças das Artérias Carótidas/cirurgia , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Tempo para o Tratamento
16.
Br J Radiol ; 97(1153): 249-257, 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38263818

RESUMO

OBJECTIVES: The current study aimed to assess myocardial microcirculation dysfunction via cardiac magnetic resonance (CMR) first-pass perfusion imaging in children with Duchenne muscular dystrophy (DMD). METHODS: In total, 67 children with DMD and 15 controls who underwent contrast-enhanced CMR first-pass perfusion imaging were enrolled in this study. CMR first-pass perfusion and late gadolinium enhancement (LGE) sequences were acquired. Further, the global, regional, and coronary artery distribution area perfusion indexes (PI), upslope (%BL), maximum signal intensity (MaxSI), time to maximum signal intensity (TTM), and baseline SI were analysed. The perfusion parameters of the LGE positive (+), LGE negative (-), and control groups were compared. Pearson correlation analysis was performed to assess the association between myocardial microcirculation and conventional cardiac function and LGE parameters. RESULTS: The LGE+ group had a significantly lower global and apical-ventricular MaxSI than the control group (all P < .05). The left anterior descending arterial (LAD), left circumflex coronary arterial (LCX), and right coronary arterial (RCA) segments of the LGE+ group had a lower upslope and MaxSI than those of the control group (all P < .05). The LAD segments of the LGE- group had a lower MaxSI than those of the control group (41.10 ± 11.08 vs 46.36 ± 13.04; P < .001). The LCX segments of the LGE- group had a lower PI and upslope than those of the control group (11.05 ± 2.84 vs 12.46 ± 2.82; P = .001; 59.31 ± 26.76 vs 68.57 ± 29.99; P = .002). Based on the correlation analysis, the upslope, MaxSI, and TTM were correlated with conventional cardiac function and LGE extent. CONCLUSIONS: Paediatric patients with DMD may present with microvascular dysfunction. This condition may appear before LGE and may be correlated with coronary artery blood supply and LGE extent. ADVANCES IN KNOWLEDGE: First-pass perfusion parameters may reveal the status of myocardial microcirculation and reflect the degree of myocardial injury at an earlier time in DMD patients. Perfusion parameters should be analysed not only via global or base, middle, and apical segments but also according to coronary artery distribution area, which may detect myocardial microvascular dysfunction at an earlier stage, in DMD patients with LGE-.


Assuntos
Distrofia Muscular de Duchenne , Humanos , Criança , Meios de Contraste , Gadolínio , Espectroscopia de Ressonância Magnética , Imagem de Perfusão
17.
J Neuroimaging ; 34(3): 308-319, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38192155

RESUMO

BACKGROUND AND PURPOSE: Frontotemporal dementia (FTD) is the second most common cause of presenile dementia. The clinical distinction between FTD, Alzheimer's disease (AD), and other dementias is a clinical challenge. Brain perfusion SPECT may contribute to the diagnosis of FTD, but its value is unclear. METHODS: We performed a systematic review to investigate the diagnostic accuracy of the brain SPECT in (1) distinguishing FTD from AD and other dementias and (2) differentiating FTD variants. RESULTS: Overall, 391 studies were retrieved on the initial search and 35 studies composed the final selection, comprising a total number of 3142 participants of which 1029 had FTD. The sensitivity and the specificity for the differential diagnosis of FTD versus AD ranged from 56% to 88% and from 51% to 93%, respectively. SPECT is not superior to the clinical method of diagnosis, but the combination of SPECT with clinical data seems to improve the diagnostic accuracy. CONCLUSION: Brain perfusion SPECT has a limited value in the diagnostic framework of FTD. SPECT can be performed when FDG-PET is not available. SPECT is recommended only for selected cases when the diagnosis is challenging using conventional methods.


Assuntos
Encéfalo , Demência Frontotemporal , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Demência Frontotemporal/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Encéfalo/diagnóstico por imagem , Reprodutibilidade dos Testes , Diagnóstico Diferencial , Prevalência , Feminino , Imagem de Perfusão/métodos
18.
J Stroke Cerebrovasc Dis ; 33(3): 107532, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38184972

RESUMO

BACKGROUND AND PURPOSE: This study aimed to investigate the clinical outcomes of emboli to distal territories (EDT) after aspiration thrombectomy in patients with acute anterior circulation occlusion. MATERIALS AND METHODS: From January 2016 to December 2022, all eligible patients who underwent endovascular treatment (EVT) due to acute anterior circulation occlusion were retrospectively reviewed. During this period, patients with EDT after EVT underwent magnetic resonance (MR) perfusion with angiography and diffusion-weighted imaging within 12 hours from recanalization. Hypoperfusion was defined as a Tmax value > 6-second volume. RESULTS: Of the 104 eligible patients (65 males, median age 74 years), 79 (76.0 %; 2a: 19, 2b: 55, 2c: 5) had hypoperfusion on perfusion MR (PWI). Complete mismatch on diffusion-weighted imaging (DWI) of the hypoperfusion area was significantly higher in patients with successful recanalization than in patients with incomplete recanalization (58.3 % vs. 31.6 %, p = 0.0437). Of the 79 patients with hypoperfusion, 24 had EDT in the M2, 39 in the M3, and 16 in the M4. Complete mismatch on DWI and PWI was significantly higher in patients with a distal EDT (M3 or M4) than in patients with an M2 EDT (65.8 % vs. 20.8 %, p < 0.001). CONCLUSIONS: EDT to the M3 or more distal branches after EVT had a higher rate of complete DWI-PWI mismatch on early follow-up MRI than EDT to M2.


Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral , Humanos , Masculino , Idoso , Angiografia por Ressonância Magnética , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Trombectomia/efeitos adversos , Acidente Vascular Cerebral/terapia , Isquemia Encefálica/terapia , Resultado do Tratamento , Imagem de Perfusão
19.
AJNR Am J Neuroradiol ; 45(2): 163-170, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38238089

RESUMO

BACKGROUND AND PURPOSE: Potential utility of flat panel CT perfusion imaging (FPCT-PI) performed immediately after mechanical thrombectomy (MT) is unknown. We aimed to assess whether FPCT-PI obtained directly post-MT could provide additional potentially relevant information on tissue reperfusion status. MATERIALS AND METHODS: This was a single-center analysis of all patients with consecutive acute stroke admitted between June 2019 and March 2021 who underwent MT and postinterventional FPCT-PI (n = 26). A core lab blinded to technical details and clinical data performed TICI grading on postinterventional DSA images and qualitatively assessed reperfusion on time-sensitive FPCT-PI maps. According to agreement between DSA and FPCT-PI, all patients were classified into 4 groups: hypoperfusion findings perfectly matched by location (group 1), hypoperfusion findings mismatched by location (group 2), complete reperfusion on DSA with hypoperfusion on FPCT-PI (group 3), and hypoperfusion on DSA with complete reperfusion on FPCT-PI (group 4). RESULTS: Detection of hypoperfusion (present/absent) concurred in 21/26 patients. Of these, reperfusion findings showed perfect agreement on location and size in 16 patients (group 1), while in 5 patients there was a mismatch by location (group 2). Of the remaining 5 patients with disagreement regarding the presence or absence of hypoperfusion, 3 were classified into group 3 and 2 into group 4. FPCT-PI findings could have avoided TICI overestimation in all false-positive operator-rated TICI 3 cases (10/26). CONCLUSIONS: FPCT-PI may provide additional clinically relevant information in a considerable proportion of patients undergoing MT. Hence, FPCT-PI may complement the evaluation of reperfusion efficacy and potentially inform decision-making in the angiography suite.


Assuntos
Isquemia Encefálica , Procedimentos Endovasculares , Acidente Vascular Cerebral , Humanos , Estudo de Prova de Conceito , Tomografia Computadorizada por Raios X/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Trombectomia , Imagem de Perfusão , Resultado do Tratamento
20.
Acad Radiol ; 31(2): 706-717, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37487880

RESUMO

RATIONALE AND OBJECTIVES: This study aimed to evaluate the diagnostic accuracies of ventilation/perfusion-single photon emission computed tomography (V/Q-SPECT) imaging modalities for acute pulmonary embolism (PE). These included, in addition to V/Q-SPECT, V/Q-SPECT with low-dose computed tomography (CT; V/Q-SPECT-CT), Q-SPECT with low-dose CT (Q-SPECT-CT), and Q-SPECT. MATERIALS AND METHODS: PubMed, Embase, CINAHL, and Web of Science databases were searched, and studies included if they studied ≥10 adult participants with acute PE and reported data on the imaging tests' diagnostic performance. Data were meta-analyzed using bivariate random effects regression model. RESULTS: Data from participants totaling 4146 from 11 V/Q-SPECT studies, 785 from 7 V/Q-SPECT-CT studies, 1196 from 7 Q-SPECT-CT studies, and 728 from five Q-SPECT studies were separately meta-analyzed. The bivariate weighted mean sensitivity and specificity were 0.94 (95% confidence interval [CI]: 0.88-0.97) and 0.95 (95% CI: 0.87-0.98) for V/Q-SPECT, 0.95 (95% CI: 0.88-0.98) and 0.99 (95% CI: 0.92-1.00) for V/Q-SPECT-CT, 0.92 (95% CI: 0.79-0.97) and 0.92 (95% CI: 0.83-0.96) for Q-SPECT-CT, and 0.89 (95% CI: 0.76-0.95) and 0.86 (95% CI: 0.67-0.95) for Q-SPECT studies. The positive and negative likelihood ratios (+LRs and -LRs) were 17.4 (6.9-44.0) and 0.06 (0.03-0.13), 76.7 (11.8-498.0) and 0.06 (0.02-0.13), 11.0 (5.3-22.9) and 0.09 (0.04-0.23), and 6.4 (2.6-15.8) and 0.13 (0.07-0.27) for V/Q-SPECT, V/Q-SPECT-CT, Q-SPECT-CT, and Q-SPECTs, respectively. CONCLUSION: In the diagnosis of acute PE, this meta-analysis showed that V/Q-SPECT-CT had the highest specificity and +LR. Conversely, Q-SPECT showed the lowest specificity and an unfavorably high -LR.


Assuntos
Embolia Pulmonar , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Humanos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Embolia Pulmonar/diagnóstico por imagem , Doença Aguda , Perfusão , Imagem de Perfusão , Testes Diagnósticos de Rotina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...