Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 341
Filtrar
1.
Front Biosci (Elite Ed) ; 16(1): 4, 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38538523

RESUMO

Elevated concentrations of toxic organic compounds observed in food products pose serious dangers to human health. Both natural and artificial pollutants can cause food contamination. The stages of food production, packaging, transportation, and storage can also largely cause the appearance of undesirable substances in food products. The health consequences of ingesting food containing toxic contaminants range from mild gastroenteritis to deaths resulting from dysfunctional internal organs and neurological syndromes. The World Health Organization (WHO) sets recommendations for the content of such chemicals in food, including a minimum allowable concentration considered safe for human consumption. However, the control of food products from chemical pollutants is necessary. Moreover, fast, sensitive, and inexpensive methods are needed to detect them at the point of need. Currently, immune analysis methods are most widely used to determine pollutants in food. The development of fluorescence polarization immunoassay (FPIA) methods in a competitive format is a powerful and modern tool for detecting organic molecules in various matrices, thereby making FPIA methods useful for food safety applications. Due to the availability of portable devices for measuring the fluorescence polarization signal, FPIA methods can be used at the point of need. The variety of fluorescent labels and recognizing elements (receptors, monoclonal and polyclonal antibodies, and nanobodies) permits fluorescence polarization (FP) assays to detect significantly lower limits of organic substances. The FP assay is a homogeneous, fast, and quantitative method. The development of various formats of FP assays makes them promising in determining food pollutants. This review summarizes publications on FP analyses for detecting organic contaminants (pesticides, hormones, toxins, antibiotics, and other pharmaceuticals) in food products during 2018-2023. Further, it demonstrates the prospects for using this method to determine pollutants at the point of need and for detecting high molecular weight substances, fungi, and bacterial infections during food safety inspections.


Assuntos
Poluentes Ambientais , Inocuidade dos Alimentos , Humanos , Imunoensaio de Fluorescência por Polarização/métodos , Polarização de Fluorescência , Anticorpos
2.
Prev Vet Med ; 222: 106079, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38056065

RESUMO

The direct methods for diagnosis of bovine brucellosis have several limitations, therefore serological tests are the basis for the diagnosis of the disease. However, a meta-analysis estimating the diagnostic sensitivity (DSe) and diagnostic specificity (DSp) on the main tests used in bovine brucellosis control programs worldwide has not been performed. This systematic review and meta-analysis aimed to estimate the DSe, DSp and thereby accuracy of serological tests individually used in the diagnosis of bovine brucellosis. The databases CABI, Cochrane Library, PubMed/MEDLINE, SciELO, Scopus and Web of Science were used to select articles. The search resulted in 5308 studies, of which 71 were selected for systematic review using quality assessment tools and 65 studies were included in the meta-analysis. For the meta-analysis, 178 assays and 11 different serological tests were considered. To estimate DSe and DSp of the tests, studies were divided according to animal selection for the studies: (1) studies that carried out a random or consecutive selection of participants (noncasecontrol studies) and (2) all studies, including casecontrol studies. Considering only the non-case-control studies to estimate the DSe, the tests that exhibited the best and worst performance were the iELISA test (indirect enzyme immunoassay - bacterial suspension as antigen - BS) (96.5%, 95% CI: 94.1-97.9%) and 2ME (2- mercaptoethanol test) (85.0%, 95% CI: 79.6-89.1%), respectively; while for DSp, the FPA (fluorescence polarization assay) (99, 7%, 95% CI: 99.5-99.8%) and PCFIA tests (protein concentration fluorescence immunoassay) (78.5%, 95% CI: 70.0-85.1%) showed better and worse performance, respectively. Overall, our results showed an overestimation in the DSe and DSp of the eleven serological tests assessed when casecontrol studies were included in the meta-analysis, which is a concern considering its impacts on the time and costs associated with populational diagnosis of the diseases, since several of these tests are routinely used in the control and eradication programs of bovine brucellosis worldwide. Furthermore, the tests that exhibited the best DSe and DSp, iELISA (BS) and FPA, respectively, are relatively easy to perform and interpret and the test which showed the best overall accuracy was FPA.


Assuntos
Brucelose Bovina , Brucelose , Doenças dos Bovinos , Bovinos , Animais , Sensibilidade e Especificidade , Brucelose Bovina/diagnóstico , Imunoensaio de Fluorescência por Polarização/métodos , Imunoensaio de Fluorescência por Polarização/veterinária , Ensaio de Imunoadsorção Enzimática/veterinária , Ensaio de Imunoadsorção Enzimática/métodos , Testes Sorológicos/veterinária , Brucelose/diagnóstico , Brucelose/veterinária , Anticorpos Antibacterianos
3.
Biosensors (Basel) ; 13(12)2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38131765

RESUMO

Dibutyl phthalate (DBP) is widely used as a plasticizer in the production of polymeric materials to give them flexibility, strength and extensibility. However, due to its negative impact on human health, in particular reproductive functions and fetal development, the content of DBP must be controlled in food and the environment. The present study aims to develop a sensitive, fast and simple fluorescence polarization immunoassay (FPIA) using monoclonal antibodies derived against DBP (MAb-DBP) for its detection in open waters. New conjugates of DBP with various fluorescein derivatives were obtained and characterized: 5-aminomethylfluorescein (AMF) and dichlorotriazinylaminofluorescein (DTAF). The advantages of using the DBP-AMF conjugate in the FPIA method are shown, the kinetics of binding of this chemical with antibodies are studied, the analysis is optimized, and the concentration of monoclonal antibodies is selected for sensitivity analysis-16 nM. The calibration dependence of the fluorescence polarization signal for the detection of DBP was obtained. The observed IC50 (DBP concentration at which a 50% decrease in the fluorescence polarization signal occurs, 40 ng/mL) and the limit of detection (LOD, 7.5 ng/mL) values were improved by a factor of 45 over the previously described FPIA using polyclonal antibodies. This technique was tested by the recovery method, and the high percentage of DBP discovery in water ranged from 85 to 110%. Using the developed method, real water samples from Lake Onega were tested, and a good correlation was shown between the results of the determination of DBP by the FPIA method and GC-MS. Thus, the FPIA method developed in this work can be used to determine DBP in open-water reservoirs.


Assuntos
Dibutilftalato , Água , Humanos , Dibutilftalato/análise , Imunoensaio de Fluorescência por Polarização/métodos , Anticorpos Monoclonais , Cromatografia Gasosa-Espectrometria de Massas
4.
Biosensors (Basel) ; 13(6)2023 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-37367029

RESUMO

BPA is a chemical commonly used in the production of polymer-based materials that can have detrimental effects on the thyroid gland and impact human reproductive health. Various expensive methods, such as liquid and gas chromatography, have been suggested for detecting BPA. The fluorescence polarization immunoassay (FPIA) is an inexpensive and efficient homogeneous mix-and-read method that allows for high-throughput screening. FPIA offers high specificity and sensitivity and can be carried out in a single phase within a timeframe of 20-30 min. In this study, new tracer molecules were designed that linked the fluorescein fluorophore with and without a spacer to the bisphenol A moiety. To assess the influence of the C6 spacer on the sensitivity of an assay based on the respective antibody, hapten-protein conjugates were synthesized and assessed for performance in an ELISA setup, and this resulted in a highly sensitive assay with a detection limit of 0.05 g/L. The lowest limit of detection was reached by employing the spacer derivate in the FPIA and was 1.0 µg/L, working range from 2 to 155 µg/L. The validation of the methods was conducted using actual samples compared to LC-MS/MS, which served as the reference method. The FPIA and ELISA both demonstrated satisfactory concordance.


Assuntos
Disruptores Endócrinos , Humanos , Imunoensaio de Fluorescência por Polarização/métodos , Cromatografia Líquida , Espectrometria de Massas em Tandem , Ensaio de Imunoadsorção Enzimática , Imunoensaio
5.
Biosensors (Basel) ; 13(4)2023 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-37185552

RESUMO

In this study, a homogeneous fluorescence polarization immunoassay (FPIA) for the detection of hazardous aquatic toxin okadaic acid (OA) contaminating environmental waters was for the first time developed. A conjugate of the analyte with a fluorophore based on a fluorescein derivative (tracer) was synthesized, and its interaction with specific anti-OA monoclonal antibodies (MAbs) was tested. A MAbs-tracer pair demonstrated highly affine immune binding (KD = 0.8 nM). Under optimal conditions, the limit of OA detection in the FPIA was 0.08 ng/mL (0.1 nM), and the working range of detectable concentrations was 0.4-72.5 ng/mL (0.5-90 nM). The developed FPIA was approbated for the determination of OA in real matrices: river water and seawater samples. No matrix effect of water was observed; therefore, no sample preparation was required before analysis. Due to this factor, the entire analytical procedure took less than 10 min. Using a compact portable fluorescence polarization analyzer enables the on-site testing of water samples. The developed analysis is very fast, easy to operate, and sensitive and can be extended to the determination of other aquatic toxins or low-molecular-weight water or food contaminants.


Assuntos
Anticorpos Monoclonais , Água , Imunoensaio de Fluorescência por Polarização/métodos , Ácido Okadáico , Fluoresceína
6.
Anal Chim Acta ; 1225: 340240, 2022 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-36038239

RESUMO

Many therapeutic drugs require monitoring of their concentration in blood followed by dose adjustments in order to ensure efficacy while minimizing adverse effects. It would be highly desirable to perform such measurements rapidly and with reduced sample volumes to support point-of-care testing. Here, we demonstrate that the concentration of small therapeutics can be determined in whole blood within paper-like membranes using Fluorescence Polarization Immunoassay (FPIA). Different types of paper-like materials such as glass microfibers, cellulose and filter paper were investigated for artefacts such as scattering or autofluorescence. Accurate determination of the fluorescence polarization of red-emitting fluorophores at sub-nanomolar concentrations was feasible within glass fiber membranes. This enabled the development of a competitive immunoassay for the quantification of the antibiotic tobramycin using only 1 µL of plasma in glass fiber micro-chambers. Furthermore, the same membrane was used for transversal separation of blood cells followed by accurate FPIA read-out at the bottom part of the micro-chamber. For quantification of tobramycin, 1 µL of whole blood was incubated with the immunoassay reagents during only 3 min before deposition in the micro-chamber and analysis. Within the therapeutic window, coefficients of variation were around 20% and recoveries between 80 and 105%. Owing to the simplified procedure requiring no centrifugation, the reduced blood sample volume and the rapid analysis time, we envision that this novel method supports the performance of therapeutic drug monitoring directly at the point of care.


Assuntos
Monitoramento de Medicamentos , Tobramicina , Imunoensaio de Fluorescência por Polarização/métodos , Vidro , Imunoensaio , Sistemas Automatizados de Assistência Junto ao Leito
7.
Anal Bioanal Chem ; 414(20): 6127-6137, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35804073

RESUMO

In order to address the widespread concerns with food safety such as adulteration and forgery in the edible oil field, this study developed a fluorescence polarization immunoassay (FPIA) based on a monoclonal antibody in a homogeneous solution system for determination of capsaicinoids in gutter cooking oil by using chemically stable capsaicinoids as an adulteration marker. The prepared fluoresceinthiocarbamyl ethylenediamine (EDF) was coupled with capsaicinoid hapten C, and the synthesized tracer was purified by thin-layer chromatography (TLC) and showed good binding to the monoclonal antibody CPC Ab-D8. The effects of concentration of tracer and recognition components, type and pH of buffer and incubation time on the performance of FPIA were studied. The linear range (IC20 to IC80) was 3.97-97.99 ng/mL, and the half maximal inhibitory concentration (IC50) was 19.73 ng/mL, and the limit of detection (LOD) was 1.56 ng/mL. The recovery rates of corn germ oil, soybean oil and peanut blend oil were in the range of 94.7-132.3%. The experimental results showed that the fluorescence polarization detection system could realize the rapid detection of capsaicinoids, and had the potential to realize on-site identification of gutter cooking oil. As a universal monoclonal antibody, CPC Ab-D8 can also specifically identify capsaicin and dihydrocapsaicin, so the proposed method can be used to quickly monitor for the presence of gutter cooking oil in normal cooking oil.


Assuntos
Culinária , Alimentos , Anticorpos Monoclonais , Imunoensaio de Fluorescência por Polarização/métodos , Limite de Detecção
8.
Lab Chip ; 22(16): 2971-2977, 2022 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-35713150

RESUMO

This paper is the first report of a non-competitive fluorescence polarization immunoassay (NC-FPIA) using a peptide as a tracer. The NC-FPIA can easily and quickly quantify the target after simply mixing them together. This feature is desirable for point-of-need applications such as clinical diagnostics, infectious disease screening, on-site analysis for food safety, etc. In this study, the NC-FPIA was applied to detect CD9, which is one of the exosome markers. We succeeded in detecting not only CD9 but also CD9 expressing exosomes derived from HeLa cells. This method can be applied to various targets if a tracer for the target can be prepared, and expectations are high for its future uses.


Assuntos
Peptídeos , Polarização de Fluorescência , Imunoensaio de Fluorescência por Polarização/métodos , Células HeLa , Humanos , Tetraspanina 29
9.
J Pharm Biomed Anal ; 214: 114719, 2022 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-35306434

RESUMO

In this study, a sensitive, rapid, homogeneous, and high-throughput fluorescence polarization immunoassay (FPIA) for the rapid screening of eight glucocorticoids (GCs) in beef samples was successfully established. Two tracers including 5-aminofluorescein-labeled dexamethasone (5-AF-DMS) and fluorescein isothiocyanate-labeled dexamethasone (FITC-DMS) were studied to select appropriate antibody-tracer pairs using four previously produced broad-specific monoclonal antibodies. An optimal combination of the antibody 12D9 and the tracer FITC-DMS was selected. Under optimal detection conditions, the half inhibitory concentrations of dexamethasone (DMS), betamethasone (BMS), prednisolone (PNS), hydrocortisone (HCS), beclomethasone (BCMS), cortisone (CS), 6-α-methylprednisone (6-α-MPNS), fludrocortisone acetate (HFCS) were 1.00, 2.17, 3.49, 12.45, 1.20, 5.66, 6.85 and 3.45 ng/mL, respectively. The average recoveries of the proposed method in beef samples ranged from 77.3-91.7% with the coefficient of variation less than 12%. The developed FPIA was time-saving that could be completed within 10 min. The FPIA was applied to beef samples and showed a good correlation with liquid chromatography-tandem mass spectrometry (LC-MS/MS) (R2 = 0.9894). Thus, the proposed method provides a rapid, reliable, sensitive, and high-throughput screening tool for the simultaneous screening of eight GCs in beef, which shows great potential in the food safety analysis.


Assuntos
Glucocorticoides , Ensaios de Triagem em Larga Escala , Animais , Anticorpos Monoclonais , Bovinos , Cromatografia Líquida , Dexametasona , Fluoresceína-5-Isotiocianato , Imunoensaio de Fluorescência por Polarização/métodos , Ensaios de Triagem em Larga Escala/métodos , Espectrometria de Massas em Tandem
10.
Biochemistry (Mosc) ; 87(12): 1679-1688, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36717456

RESUMO

Due to its unique structure and properties, human breast milk lactoferrin (hLF) has many nutritional and health-promoting functions in infants, including protection against inflammation and bacterial infections. The lack of LF in breastmilk or formula can result in the weakening of the infant's immune system. Noncompetitive polarization fluorescence immunoassay (FPIA) is a promising method for hLF quantification in milk and dairy products, which does not require the separation of the bound and free protein and allows to avoid time-consuming sample preparation. The use of fluorescently labeled single-domain camelid antibodies (nanobodies) for protein recognition in FPIA makes it possible to quantify relatively large antigens, in particular, hLF. In this work, we used previously obtained fluorescein isothiocyanate (FITC)-conjugated anti-hLF5 and anti-hLF16 nanobodies, which selectively recognized two different human lactoferrin epitopes, but did not bind to goat lactoferrin. The kinetics of hLF interaction with the FITC-labeled nanobodies was studied. The dissociation constant (KD) for the anti-LF5 and antiLF16 nanobodies was 3.2 ± 0.3 and 4.9 ± 0.4 nM, respectively, indicating the high-affinity binding of these nanobodies to hLF. We developed the FPIA protocol and determined the concentration of FITC-labeled anti-hLF5 and anti-hLF16 nanobodies that provided the optimal fluorescence signal and stable fluorescence polarization value. We also studied the dependence of fluorescence polarization on the hLF concentration in the noncompetitive FPIA with FITC-anti-hLF5 nanobody. The detection limit for hLF was 2.1 ± 0.2 µg/ml and the linear range for determining the hLF concentration was 3-10 µg/ml. FPIA is commonly used to assay low-molecular-weight substances; however, the use of fluorescently labeled nanobodies allows quantification of high-molecular-weight proteins. Here, we demonstrated that FPIA with fluorescently labeled nanobodies can be used for hLF quantification in milk.


Assuntos
Anticorpos de Domínio Único , Feminino , Humanos , Animais , Anticorpos de Domínio Único/análise , Anticorpos de Domínio Único/química , Anticorpos de Domínio Único/metabolismo , Imunoensaio de Fluorescência por Polarização/métodos , Lactoferrina/análise , Lactoferrina/química , Lactoferrina/metabolismo , Leite/química , Leite/metabolismo , Fluoresceína-5-Isotiocianato , Fluoresceína/química
11.
Anal Bioanal Chem ; 413(17): 4459-4469, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34137913

RESUMO

In this paper, five fluorescein-labeled dehydroepiandrosterone (DHEA) derivatives (tracers) with different chain lengths between the fluorescein and hapten were synthesized and featured so as to establish a fluorescence polarization immunoassay (FPIA) for DHEA detection in human urine samples with previously prepared polyclonal antibody against DHEA. The outcomes of the structure of tracer on FPIA sensitivity were investigated. Under the optimal condition, the fluorescence polarization value (FP) decreases linearly in DHEA concentration, ranging from 1.6 to 243.3 ng mL-1, with the limit of detection of 1.1 ng mL-1 and IC50 value of 25.1 ng mL-1. Moreover, the developed FPIA was time-saving as it could complete the detection within 3 min. FPIA and commercial enzyme-linked immunosorbent assay kit were both applied to analyze the spiked human urine samples with DHEA. Excellent recoveries (92.1-108.0%) and satisfactory correlation coefficient (R2 = 0.98) were acquired with the two methods, indicating that the developed FPIA was a fast and efficient screening immunoassay with accuracy and sensitivity for DHEA detection in human urine samples. Graphical abstract.


Assuntos
Desidroepiandrosterona/urina , Imunoensaio de Fluorescência por Polarização/métodos , Fluoresceína/química , Imunoensaio de Fluorescência por Polarização/economia , Corantes Fluorescentes/química , Humanos , Limite de Detecção , Fatores de Tempo
12.
Food Chem ; 360: 130020, 2021 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-34000636

RESUMO

Peptides obtained from phage display libraries are valuable reagents for small-molecule immunoassays. However, their application in fluorescence polarization immunoassays (FPIAs) is limited by phage particles. Here, monomer, dendrimer-like dimer, tetramer peptidomimetic and anti-immunocomplex tracers were designed and synthesized using lysine as special scaffolds and spacers to develop competitive and noncompetitive FPIAs for benzothiostrobin. The affinity between tracers and monoclonal antibodies or immunocomplexes increased with the tracer valence. A higher signal-to-noise ratio and sensitivity could be generated in the FPIAs based on tetramer tracers. The sensitivities of competitive (50% inhibitory concentration) and noncompetitive (50% saturation concentration) FPIAs were 19.71 ± 4.65 and 40.43 ± 2.73 ng mL-1, respectively. The spiked recoveries were 78.3%-105.2% with relative standard deviations (RSDs) of 0.7%-15.4% for the competitive FPIA, while 78.7%-115.3% with RSDs of 0.7%-12.5% for the noncompetitive FPIA. The amounts of benzothiostrobin in rice detected by the FPIAs were consistent with those detected by high performance liquid chromatography.


Assuntos
Acrilatos/análise , Benzotiazóis/análise , Dendrímeros/química , Fluoresceína-5-Isotiocianato/química , Imunoensaio de Fluorescência por Polarização/métodos , Peptídeos/química
13.
J Wildl Dis ; 57(2): 386-392, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33822148

RESUMO

We evaluated hemolyzed, bacterially contaminated, and Nobuto filter paper-derived serum, collected from 50 Rocky Mountain elk (Cervus elaphus nelson) in 2017 and 2019, divided into eight treatments to determine antibody retention. Serum was analyzed on Brucella abortus-specific fluorescence polarization assay utilizing plates and tubes. Reference titers and serostatus were compared to serum held at 22 C for 4, 8, 12, and 16 d; frozen clotted blood; blood with 2% and 10% elk rumen content (held for 8 d at 22 C); and serum eluted from Nobuto filter paper. Using Cohen's kappa test of agreement, plate assay serostatus agreement was substantial or outstanding in all treatments. Serostatus agreement was outstanding in all treatments utilizing tubes. The mean change in score (treatment minus reference) showed significant negative bias in serosuspect or seropositive animals in the frozen, 2% rumen, and 10% rumen treatments on the plate assay, and the day 16 and 10% rumen treatments on the tube assay, that could ultimately result in an animal being misclassified into a serosuspect or seronegative category. Serum eluted from Nobuto filter paper produced inconsistent results and is not recommended as an alternative to serum derived from blood. Although the potential for misclassification of animals with low titers exists, analyzing hemolyzed and bacterially contaminated serum from Brucella abortus nonendemic areas can increase sample size and the potential to detect seropositive animals.


Assuntos
Anticorpos Antibacterianos/análise , Brucella abortus/isolamento & purificação , Brucelose/veterinária , Cervos/sangue , Imunoensaio de Fluorescência por Polarização/métodos , Manejo de Espécimes , Animais , Brucelose/sangue , Brucelose/diagnóstico
14.
Anal Bioanal Chem ; 413(18): 4619-4623, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33547481

RESUMO

Nowadays, the diagnosis of viral infections is receiving broad attention. We have developed a non-competitive fluorescence polarization immunoassay (NC-FPIA), which is a separation-free immunoassay, for a virus detection. H5 subtype avian influenza virus (H5-AIV) was used as a model virus for the proof of concept. The fluorescein-labeled Fab fragment that binds to H5 hemagglutinin was used for NC-FPIA. The purified H5-AIV which has H5 hemagglutinin was mixed with the fluorescein-labeled Fab fragment. After that, the degree of fluorescence polarization was measured with a portable FPIA analyzer. H5-AIV was successfully detected with an incubation time of 15 min. In addition, the portable FPIA analyzer enables performance of on-site NC-FPIA with a sample volume of 20 µL or less. This is the first research of detecting a virus particle by FPIA. This NC-FPIA can be applied to rapid on-site diagnosis of various viruses.


Assuntos
Imunoensaio de Fluorescência por Polarização/métodos , Virus da Influenza A Subtipo H5N1/isolamento & purificação , Influenza Aviária/virologia , Animais , Galinhas , Imunoensaio de Fluorescência por Polarização/instrumentação , Virus da Influenza A Subtipo H5N1/genética , Reação em Cadeia da Polimerase , Sensibilidade e Especificidade
15.
SLAS Discov ; 26(5): 740-746, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33402044

RESUMO

The innate immune response to cancer is initiated by cytosolic DNA, where it binds to cGAS and triggers type I interferon (IFN) expression via the STING receptor, leading to activation of tumor-specific T cells. Ectonucleotide pyrophosphatase/phosphodiesterase 1 (ENPP1) has been identified as the primary enzyme responsible for degrading cGAMP, and therefore it is under intense investigation as a therapeutic target for cancer immunotherapy. ENPP1 hydrolyzes cGAMP to produce AMP and GMP, and hydrolyzes ATP and other nucleotides to monophosphates and pyrophosphate. We developed a robust, high-throughput screening (HTS)-compatible enzymatic assay method for ENPP1 using the Transcreener AMP2/GMP2 Assay, a competitive fluorescence polarization (FP) immunoassay that enables direct detection of AMP and GMP in a homogenous format. The monoclonal antibody used in the Transcreener AMP2/GMP2 Assay showed more than 104-fold selectivity for AMP and GMP versus cGAMP, and 3000-fold selectivity for AMP over ATP, indicating that the assay can be used for detection at initial velocity with either substrate. A working concentration of 100 pM ENPP1 was determined as optimal with a 60 min reaction period, enabling screening with very low quantities of enzyme. A Z' value of 0.72 was determined using ATP as substrate, indicating a high-quality assay. Consistent with previous studies, we found that ENPP1 preferred ATP as a substrate when compared with other nucleotides like GTP, ADP, and GDP. ENPP1 showed a 20-fold selectivity for 2'3'cGAMP compared with 2'3'c-diGMP and showed no activity with 3'3'c-diAMP. The Transcreener AMP2/GMP2 Assay should prove to be a valuable tool for the discovery of ENPP1 lead molecules.


Assuntos
Descoberta de Drogas/métodos , Ensaios de Triagem em Larga Escala/métodos , Inibidores de Fosfodiesterase/química , Inibidores de Fosfodiesterase/farmacologia , Diester Fosfórico Hidrolases/química , Pirofosfatases/antagonistas & inibidores , Pirofosfatases/química , Imunoensaio de Fluorescência por Polarização/métodos , Humanos
16.
Anal Bioanal Chem ; 413(4): 999-1007, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33241445

RESUMO

Pharmacologically active compounds are often detected in wastewater and surface waters. The nonsteroidal anti-inflammatory drug diclofenac (DCF) was included in the European watch list of substances that requires its environmental monitoring in the member states. DCF may harmfully influence the ecosystem already at concentrations ≤ 1 µg L-1. The fast and easy quantification of DCF is becoming a subject of global importance. Fluorescence polarization immunoassay (FPIA) is a homogeneous mix-and-read method which does not require the immobilization of reagents. FPIA can be performed in one phase within 20-30 min, making it possible to analyse wastewater without any complicated pre-treatment. In this study, new tracer molecules with different structures, linking fluorophores to derivatives of the analyte, were synthesized, three homologous tracers based on DCF, two including a C6 spacer, and one heterologous tracer derived from 5-hydroxy-DCF. The tracer molecules were thoroughly assessed for performance. Regarding sensitivity of the FPIA, the lowest limit of detection reached was 2.0 µg L-1 with a working range up to 870 µg L-1. The method was validated for real wastewater samples against LC-MS/MS as reference method with good agreement of both methods. Graphical abstract.


Assuntos
Anti-Inflamatórios não Esteroides/análise , Diclofenaco/análise , Imunoensaio de Fluorescência por Polarização/métodos , Águas Residuárias/análise , Poluentes Químicos da Água/análise , Limite de Detecção
17.
Pediatr Blood Cancer ; 68(3): e28788, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33164288

RESUMO

A retrospective, single-center, observational study evaluated the difference in time to clearance of high-dose methotrexate between the fluorescence polarization immunoassay (FPIA) and ARK methotrexate assay in pediatric hematology/oncology patients. The post-ARK immunoassay group had an increase in clearance time of 33 h/cycle and 31% increase in cycles with delayed clearance. On posthoc analysis, use of an adjusted clearance threshold of <0.15 µmol/L post-ARK immunoassay, as opposed to the traditional <0.1 µmol/L threshold, would have similar incidence of delayed clearance. The ARK immunoassay demonstrated a positive bias compared to the FPIA in clinical practice, which led to an institutional policy change.


Assuntos
Antimetabólitos Antineoplásicos/sangue , Imunoensaio de Fluorescência por Polarização/métodos , Neoplasias Hematológicas/tratamento farmacológico , Imunoensaio/métodos , Metotrexato/sangue , Adolescente , Antimetabólitos Antineoplásicos/administração & dosagem , Criança , Relação Dose-Resposta a Droga , Feminino , Seguimentos , Neoplasias Hematológicas/sangue , Neoplasias Hematológicas/patologia , Humanos , Masculino , Metotrexato/administração & dosagem , Monitorização Fisiológica , Prognóstico , Estudos Retrospectivos
18.
Anal Chem ; 92(21): 14393-14397, 2020 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-33094615

RESUMO

Fluorescent polarization immunoassay (FPIA) is a single-step immunoassay method that is applicable to point-of-care testing; however, its applicability to large biomolecules has been restricted because ordinary FPIA is a competitive assay. Here, we report a noncompetitive FPIA using the variable domain from the heavy chain of a camelid antibody (VHH antibody). FPIA with VHH was successfully used to quantitate rabbit immunoglobulin G (IgG) and demonstrated a wider response range than that observed with antibody-binding (Fab) fragment. Then, using a portable FPIA instrument, a VHH-based immunoassay of human IgG in a human serum certified reference material was demonstrated.


Assuntos
Imunoensaio de Fluorescência por Polarização/métodos , Imunoglobulina G/análise , Animais , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Limite de Detecção , Coelhos , Anticorpos de Domínio Único/imunologia
19.
J Microbiol Methods ; 170: 105858, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32014437

RESUMO

Brucellosis is an important zoonosis that constitutes a serious public health hazard which is caused by a bacterium belonging to the genus Brucella. In the present study, two highly specific serological tests for brucellosis diagnosis, fluorescence polarization assay (FPA) and competitive ELISA (cELISA) were standardized in the laboratory, evaluated and compared with rose bengal plate test (RBPT), indirect ELISA (iELISA) and commercial cELISA kit. For test evaluation, 1386 serum samples [apparently healthy animals (n = 260), samples from Brucella infected farms (n = 701) and B. abortus S19 vaccinated animals (n = 425)] were analyzed to assess suitable diagnostic test in B. abortus S19 post vaccinated bovine population. In apparently healthy brucellosis free farms, RBPT, iELISA, in-house FPA and cELISA were found to be highly specific than commercial cELISA. Commercial cELISA kit was comparatively more sensitive than other serological tests in samples collected from infected farms. The FPA showed sensitivity nearly equal to RBPT and in-house cELISA showed greater sensitivity than RBPT in infected farms. In animals with persistent vaccinal antibodies, only in-house FPA and cELISA recorded higher specificity of 87.64 and 90.27%, respectively. The other tests, RBPT and iELISA displayed similar reactivity with vaccine antibodies to that of infection antibodies whereas commercial cELISA kit showed an intermediate specificity of 47.69%. With these findings, RBPT, iELISA and cELISA are suggested for screening infected herds, and in-house developed FPA and cELISA tests with a proven specificity can be used for confirmatory diagnosis of brucellosis in B. abortus S19 post vaccinated animal populations.


Assuntos
Anticorpos Antibacterianos/sangue , Brucella abortus/imunologia , Brucelose Bovina/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , Imunoensaio de Fluorescência por Polarização/métodos , Testes Sorológicos/veterinária , Animais , Vacinas Bacterianas/imunologia , Brucella abortus/isolamento & purificação , Bovinos , Programas de Rastreamento/métodos , Sensibilidade e Especificidade , Vacinação/veterinária
20.
J Agric Food Chem ; 67(41): 11536-11541, 2019 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-31589045

RESUMO

Limited reports on the use of nanobodies (Nbs) in fluorescence polarization immunoassay (FPIA) aroused us to explore if the small size of Nbs is a drawback for the development of sensitive FPIA to small molecular compounds, particularly since FPIA is a technology strongly dependent on molecular weight. In the present work, three different molecular weight Nbs against 3-phenoxybenzoic acid (3-PBA), an exposure biomarker of pyrethroid insecticides, including bare Nbs (15 kDa), Nbs-Avidin (Nbs-AV, 60 kDa), and Nbs-Alkaline phosphatase (Nbs-AP, 130 kDa) were specifically generated to cover distinct regions on the polarization and molecular weight relationship curve for a fluorescein tracer. In competitive FPIA, similar half-maximal inhibitory concentrations (IC50) of 3-PBA of 16.4, 12.2, and 14.8 ng mL-1 were obtained for Nbs, Nbs-AV, and Nbs-AP, respectively, indicating that the size of Nbs in the range tested had no significant effect on the sensitivity of the resulting competitive FPIA. An IC50 of 20.2 ng mL-1 for an anti-3-PBA polyconal antibody based FPIA further demonstrated the performance of Nbs, which was comparable to that of traditional antibodies in FPIA. Spike-recovery studies showed good and reproducible recovery of 3-PBA in urine samples, demonstrating the applicability of Nb-based FPIA. Overall, our results show that Nb-based FPIA achieves sensitivity levels of FPIA based on conventional antibodies and further indicate that Nb absolutely meets the sensitivity requirement of FPIA.


Assuntos
Benzoatos/urina , Imunoensaio de Fluorescência por Polarização/métodos , Inseticidas/toxicidade , Piretrinas/toxicidade , Anticorpos de Domínio Único/química , Biomarcadores/urina , Exposição Ambiental/análise , Imunoensaio de Fluorescência por Polarização/instrumentação , Humanos , Inseticidas/análise , Piretrinas/análise , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...