1.
J Contemp Dent Pract ; 25(3): 250-259, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38690699

RESUMO

AIM AND BACKGROUND: To compare the root canal volume in primary teeth using hand and rotary instruments and to evaluate root canal filling techniques and flow of root canal obturation materials in the postinstrumented root canal volume using spiral computed tomography (SCT). MATERIALS AND METHODS: Freshly extracted 16 primary molars were randomly divided into two groups and subjected to SCT analysis before and after instrumentation. For the manual technique (group I) with eight teeth were prepared using K files, and rotary (group II) eight teeth preparation was performed with ProTaper files. The filled volume in each canal was measured using SCT, and the percentage of obturated volume was calculated. The data were statistically analyzed using the Mann-Whitney U test. RESULTS: There was a statistically significant difference in both groups' volume of root canals enlarged. Even though both K files and the ProTaper system brought about enlarged canals after instrumentation, there was a statistically significant increase in volume after using K files in two canals. In three canals, there was a statistically significant increase in volume after using ProTaper. Irrespective of the obturation technique and materials used, there is no statistically significant difference in the volume after obturation. CONCLUSION: From the results of this study, the ProTaper file system shows suitable volumetric enlargement up to an optimum level, which is needed in primary root canal walls, and is better in canal shaping, as evidenced by good postobturation volume. CLINICAL SIGNIFICANCE: The traditional method of cleaning and shaping the root canals in permanent teeth using manual stainless-steel files can lead to undesirable curvatures in root canal morphology, making correctly filling the root canals difficult. It is also time-consuming and sometimes leads to iatrogenic errors. Rotary nickel-titanium (Ni-Ti) instrumentation techniques have been developed to overcome these problems. How to cite this article: Yadav DBUC, Varma RB, Kumar JS, et al. Volumetric Analysis of Hand and Rotary Instrumentation, Root Canal Filling Techniques, and Obturation Materials in Primary Teeth Using Spiral CT. J Contemp Dent Pract 2024;25(3):250-259.


Assuntos
Cavidade Pulpar , Dente Molar , Materiais Restauradores do Canal Radicular , Obturação do Canal Radicular , Preparo de Canal Radicular , Tomografia Computadorizada Espiral , Dente Decíduo , Humanos , Obturação do Canal Radicular/métodos , Dente Decíduo/diagnóstico por imagem , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Cavidade Pulpar/diagnóstico por imagem , Cavidade Pulpar/anatomia & histologia , Tomografia Computadorizada Espiral/métodos , Dente Molar/diagnóstico por imagem , Instrumentos Odontológicos , Técnicas In Vitro
2.
Dent Med Probl ; 61(2): 269-278, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38686969

RESUMO

Nickel-titanium (NiTi) file separation during endodontic treatment is an undesirable event. This phenomenon needs to be understood by knowing the factors influencing fracture in endodontic files. There is a large amount of literature where these factors and their influence have been studied, increasing the knowledge about the mechanisms involved, mainly related to wire technology, file shapes and geometry, operator manipulation, the anatomy of the root canal, and the irrigation and sterilization processes. As many factors are involved, the complexity of the fracture phenomena increases and the isolated correlation of one factor with the file fracture becomes a small part of comprehending the separation phenomena. This thematic review aims to compile important reports from 2014 to 2022 on the factors influencing NiTi file separation. The information obtained was classified into wire technology, file geometry, operational aspects, irrigation and sterilization, and anatomy. For this purpose, the Scopus, Web of Science and ScienceDirect databases were consulted using a search string. Filters were applied to consolidate the final set of relevant papers covering the subject of factors influencing endodontic file separation. It was found that the fracture of NiTi files incorporates different mechanisms that operate simultaneously during the endodontic procedure and strongly affect the instrument performance. The collected information promotes good practices to prevent file separation.


Assuntos
Níquel , Preparo de Canal Radicular , Titânio , Humanos , Preparo de Canal Radicular/instrumentação , Falha de Equipamento , Desenho de Equipamento , Esterilização , Instrumentos Odontológicos
3.
Shanghai Kou Qiang Yi Xue ; 33(1): 54-58, 2024 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-38583025

RESUMO

PURPOSE: To compare the forming ability of four kinds of nickel-titanium instrument preparation resin for simulated curved root canal. METHODS: A total of 40 single bend resin simulated root canals were randomly divided into 4 groups with 10 in each group. Four kinds of nickel-titanium instruments (ProTaper, HyFlex EDM, WaveOne Gold and Reciproc Blue) were used for root canal preparation, and divided into group A, group B, group C and group D. The preparation time of the four groups was compared, the root canal images before and after preparation were analyzed by computer image analysis software, and the changes of the preparation time, curvature and curvature radius of the four groups were recorded. With the root tip as the center of the circle, the radius of 1-10 mm was selected as concentric circle arcs. The detection points were overlapping root canal intersection points. The resin removal amount and center positioning force of the inner and outer walls of the root canal at different detection points were recorded. Statistical analysis was performed with SPSS 20.0 software package. RESULTS: The root canal preparation time in group A was significant longer than that in group B, C and D(P<0.05), but there was no significant difference in the curvature and curvature radius of the root canal among the four groups (P>0.05). The removal amount of resin from the root canal wall in group C was significant lower than that in group A, B and D (P<0.05) when the distance from the detection point to the apical foramina was 5, 6, 8, 9 and 10 mm, respectively. The removal amount of resin from the outer wall of the root canal in group C was significant lower than that in group A, B and D (P<0.05) when the distance from the detection point to the apical foramina was 5, 6, 7, 9 and 10 mm, respectively. The root tip offset of group A from the detection point to the apical hole of 1, 2, 3, 4, 6, 7, 8, 9 and 10 mm was significant greater than that of group B, C and D(P<0.05). CONCLUSIONS: Among the four instruments, ProTaper has the largest apical deviation, HyFlex EDM, WaveOne Gold and Reciproc Blue have better ability of root canal forming.


Assuntos
Cavidade Pulpar , Titânio , Níquel , Instrumentos Odontológicos , Preparo de Canal Radicular/métodos , Desenho de Equipamento
5.
BMC Oral Health ; 24(1): 416, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38580975

RESUMO

OBJECTIVE: To investigate the status and related factors of sterilizers in dental health-care settings in Yunnan Province, with the aim of providing a theoretical basis for the health administrative department to formulate regional quality control programs and systems, proposing reasonable suggestions for optimizing the allocation of sterilizer resources in Yunnan's dental health-care settings, thereby improving resource utilization efficiency. METHODS: This cross-sectional survey was conducted in 2600 dental health-care settings in Yunnan Province in March 2020. Uni-variable linear regression, multi-variable linear regression, curve fitting and threshold effect analysis were used to understand the relationship between dental units and sterilizers. RESULTS: A total of 2600 dental health-care settings were included. The disinfection and sterilization work were mainly completed by the dental department in 1510(58.1%) institutions. 44(1.7%) institutions were not allocated sterilization equipment, and 1632 (62.8%) had only one sterilizer. The median allocation of sterilizers was 1.0. Uni-variable linear regression showed significant differences in covariates such as dental unit, dental handpiece, disinfection equipment, dentist, and dental assistant, which were more sensitive (p < 0.001) and statistically significant. The adjusted model was more stable in the multi-variable linear regression, and the differences in covariates between different settings were statistically significant. Curve fitting revealed an S-shaped curvilinear relationship between the number of dental units and sterilizers in oral healthcare settings. CONCLUSION: The disinfection and sterilization work was mainly completed by the dental department in dental health-care settings in Yunnan Province. Sterilizer allocation increases with the number of dental units, but some institutions have insufficient allocation of sterilizer and manpower resources, resulting in certain risks of infection control. Thus, it is necessary to strengthen supervision, inspection and regional quality control work in infection control of dentistry.


Assuntos
Desinfecção , Controle de Infecções , Humanos , Estudos Transversais , China , Instrumentos Odontológicos
6.
Eur Arch Paediatr Dent ; 25(2): 181-189, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38461490

RESUMO

PURPOSE: Pulpectomy can be used for the management of deep dentinal carious lesions in primary teeth which can be restored. Mechanical preparation of root canals can be performed using hand or NiTi rotary files. However, this may cause dentinal stress and consequently dentinal microcracks. Hence, the aim was comparative evaluation of hand and rotary file systems on dentinal microcrack formation during pulpectomy procedure in primary teeth. METHODS: 60 extracted primary molar teeth were selected comprising of 80 root canals. Simple random sampling was used to divide root canals into four groups (n = 20): Group A-Hedstrom file, Group B-Pro AF Baby Gold rotary, Group C-ProTaper Next rotary, and Group D-unprepared group. Assessment was conducted on presence or absence of microcracks using Chi square test (p < 0.05). RESULTS: The total number of microcracks in Group A: one (5%), Group B: four (20%), Group C: nine (45%) and Group D: zero (0%) which was statistically significant (p = 0.002). At cervical third, the number of microcracks seen with Group A: one (5%), Group B: zero (0%), Group C: five (25%) and Group D: zero (0%) (p = 0.005). At the middle third, the number of microcracks seen in Group A: zero (0%), Group B: four (20%), Group C: four (20%) and Group D: zero (0%) (p = 0.029). CONCLUSION: The study concluded that dentinal microcracks are formed with both hand and rotary file systems in primary teeth. ProTaper Next showed significantly higher number of microcracks, followed by ProAF Baby Gold and H files.


Assuntos
Dentina , Pulpectomia , Preparo de Canal Radicular , Dente Decíduo , Humanos , Dente Decíduo/cirurgia , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Pulpectomia/métodos , Dentina/lesões , Técnicas In Vitro , Instrumentos Odontológicos/efeitos adversos , Dente Molar/cirurgia , Desenho de Equipamento , Cavidade Pulpar/cirurgia , Níquel
7.
Eur Arch Paediatr Dent ; 25(2): 227-235, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38472709

RESUMO

PURPOSE: To evaluate the volumetric changes of two recently introduced paediatric rotary file systems in comparison with conventional hand file systems in primary maxillary canines using an ultra-high-resolution nano-computed tomography. METHODS: This in vitro study was performed in extracted primary maxillary canines based on certain inclusion and exclusion criteria. Samples were prepared, and working length was determined after the pre-operative scan using a high-resolution nano-CT device (SkyScan 2214, Bruker, Kontich, Belgium). A single well-experienced paediatric dentist prepared the canals using three file systems: Kedo-S plus, Kedo-SG blue and hand K-files. All samples were subjected to post-operative scans performed similar to pre-operative scans. Image reconstruction was performed with NRecon software for 3D volumetric visualisation and analysis of the root canals. RESULTS: Kedo-SG blue file systems had the highest mean difference in the canal volume (4.05%). Hand K-files had the least difference at (3.71%) of canal volume. Kedo-S plus file system had a moderate mean canal volume difference (3.82%) which is closer to hand K-files. Intergroup comparison between the three groups showed that the mean difference in canal volume was statistically significant between all three file systems (p = 0.000). CONCLUSION: Within the limitations of the current study, rotary file systems produced a significant enlargement of canals as compared to hand files. Kedo-SG blue created a uniform preparation of the canal cervico-apically. Kedo-S plus files were prepared more coronally with minimal preparation apically as close to the preparation of hand files. TRIAL REGISTRATION: Trial registration number: IHEC/SDC/PEDO-2103/22/651, Date of registration: 2022.


Assuntos
Dente Canino , Cavidade Pulpar , Maxila , Preparo de Canal Radicular , Dente Decíduo , Humanos , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Dente Canino/diagnóstico por imagem , Dente Canino/anatomia & histologia , Dente Decíduo/diagnóstico por imagem , Dente Decíduo/anatomia & histologia , Maxila/diagnóstico por imagem , Técnicas In Vitro , Cavidade Pulpar/diagnóstico por imagem , Cavidade Pulpar/anatomia & histologia , Instrumentos Odontológicos , Desenho de Equipamento
8.
Int Endod J ; 57(5): 601-616, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38376108

RESUMO

AIM: To compare eight large- and low-tapered heat-treated reciprocating instruments regarding their design, metallurgy, mechanical properties, and irrigation flow through an in silico model. METHODOLOGY: A total of 472 new 25-mm E-Flex Rex (25/.04 and 25/.06), Excalibur (25/.05), Procodile (25/.06), Reciproc Blue R25 (25/.08v), WaveOne Gold Primary (25/.07v), and Univy Sense (25/.04 and 25/.06) instruments were evaluated regarding their design (stereomicroscopy, scanning electron microscopy, and 3D surface scanning), metallurgy (energy-dispersive X-ray spectroscopy and differential scanning calorimetry), and mechanical performance (cyclic fatigue, torsional resistance, cutting ability, bending and buckling resistance). Computational fluid dynamics assessment was also conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparations. Kruskal-Wallis and one-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS: Instruments presented variations in blade numbers, helical angles, and tip designs, with all featuring non-active tips, symmetrical blades, and equiatomic nickel-titanium ratios. Cross-sectional designs exhibited an S-shaped geometry, except for WaveOne Gold. Univy 25/.04 and Reciproc Blue displayed the smallest and largest core diameters at D3. Univy 25/.04 and E-Flex Rec 25/.04 demonstrated the longest time to fracture (p < .05). Reciproc Blue and Univy 25/.04 exhibited the highest and lowest torque to fracture, respectively (p < .05). Univy 25/.04 and Reciproc Blue had the highest rotation angles, whilst E-Flex Rec 25/.06 showed the lowest angle (p < .05). The better cutting ability was observed with E-Flex Rec 25/.06, Procodile, Excalibur, and Reciproc Blue (p > .05). Reciproc R25 and E-Flex Rec showed the highest buckling resistance values (p < .05), with WaveOne Gold being the least flexible instrument. The impact of instruments' size and taper on wall shear stress and apical pressure did not follow a distinct pattern, although Univy 25/.04 and E-Flex Rec 25/.06 yielded the highest and lowest values for both parameters, respectively. CONCLUSIONS: Low-tapered reciprocating instruments exhibit increased flexibility, higher time to fracture, and greater angles of rotation, coupled with reduced maximum bending loads and buckling strength compared to large-tapered instruments. Nevertheless, low-tapered systems also exhibit lower maximum torque to fracture and inferior cutting ability, contributing to a narrower apical canal enlargement that may compromise the penetration of irrigants in that region.


Assuntos
Instrumentos Odontológicos , Titânio , Estudos Transversais , Desenho de Equipamento , Teste de Materiais , Estresse Mecânico , Titânio/química , Preparo de Canal Radicular , Metalurgia
9.
J Endod ; 50(4): 520-526, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38311116

RESUMO

INTRODUCTION: This study aimed to evaluate the effects from the memory-triple (MT) heat treatment on the fatigue resistance of the Reciproc by comparison with the file systems of same geometry. METHODS: Reciproc files subjected to MT heat treatment technology were designated as Group RMT and were compared with the original Reciproc (Group REC) and Reciproc Blue (Group REB). Each NiTi file from 3 groups (n = 15) was operated reciprocally with a repetitive up-and-down movement in the curved canal with 4 mm of pecking distance inside of the simulated canal at body temperature. When each file fractured, the time until fracture was recorded. The length of the fractured fragment was measured. Fractured fragments were observed under scanning electron microscope (SEM) to evaluate the topographic features of the surface. Differential scanning calorimetry (DSC) analysis was performed to estimate phase transformation temperatures. One-way analysis of variance and Duncan post hoc comparison were applied to compare among the groups at a significance level of 95%. RESULTS: RMT showed significantly higher fracture resistance (P < .05), whereas there was no difference in fatigue resistance between REC and REB. SEM examination showed the files from the 3 groups had similar topographic features. RMT showed a peak of austenite peak (Ap) at a temperature (52°C) higher than body temperature, whereas REC and REB showed Ap at 37 and 32°C, respectively. CONCLUSIONS: Under the condition of this study, the new heat treatment technique of MT technology could enhance the fatigue fracture resistance of the reciprocating files made of M-wire and Blue-wire.


Assuntos
Temperatura Alta , Preparo de Canal Radicular , Falha de Equipamento , Estresse Mecânico , Instrumentos Odontológicos , Teste de Materiais , Desenho de Equipamento , Titânio
10.
J Endod ; 50(5): 619-626, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38311114

RESUMO

INTRODUCTION: Determination of the glide path is recommended before using rotary instruments. This study aimed to evaluate the dynamic cyclic fatigue resistance of new and used glider rotary instruments in up to 6 root canals. METHODS: Seventy-two TruNatomy Glider files were used for the preparation of root canals of extracted lower molars, which were then submitted to the dynamic cyclic fatigue test carried out in a curved metallic artificial canal. The instruments were divided into 4 groups (n = 18): Control group, new instruments without any use in the root canal; Group 2U, instruments used in 2 mesial canals; Group 4U, instruments used in 4 mesial canals; Group 6U, instruments used in 6 mesial canals. The time to failure (TF) of the instrument was recorded, and the number of cycles to failure (NCF) was calculated. The data were submitted to 1-way analysis of variance and to the Games-Howell test for multiple comparisons, adopting a significance level of 5%. RESULTS: TF and NCF were significantly affected by the number of file uses. The Games-Howell test revealed that TF and NCF were significantly greater in the control group than in Group 4U. In Group 2U, TF and NCF were intermediate and not significantly different from the control group. Group 6U had significantly lower TF and NCF than all other groups. CONCLUSION: The TruNatomy Glider can be used as a glide path for up to 2 mesial canals of mandibular molars, whereas its use on 4 or 6 root canals is not suggested.


Assuntos
Falha de Equipamento , Preparo de Canal Radicular , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Humanos , Instrumentos Odontológicos , Desenho de Equipamento , Técnicas In Vitro , Dente Molar , Análise do Estresse Dentário , Cavidade Pulpar , Teste de Materiais
11.
São Paulo; s.n; 20240222. 152 p.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1531900

RESUMO

Introdução: Mucosite oral é um efeito colateral dos tratamentos oncológicos, caracterizado por lesões orais que vão de eritema a úlceras que podem causar dor intensa e restrição de dieta. É conhecida como condição limitante e de grande impacto na qualidade de vida (QV). Objetivo: Elaborar um novo instrumento para avaliar a QV relacionada à mucosite oral. Material e método: Pesquisa através de métodos mistos, iniciando com entrevistas qualitativas analisadas pelo método de Bardin e método Reinert, com o programa IRAMUTEQ, seguido do método Delphi com quatro rodas de entrevistas e discussões com especialistas. A primeira versão do instrumento passou por um pré-teste com 10 pacientes, com análise quantitativa e qualitativa, seguido de outra rodada de especialistas. Resultados: O material das entrevistas qualitativas apontou os termos dor e alimentação como centrais na experiência de mucosite oral, além de fornecerem várias palavras-chave para definição dos constructos. Baseado nesse material e na literatura, 4 especialistas formularam 34 perguntas enviadas para outros 10 especialistas de diferentes regiões e instituições brasileiras que analisaram a clareza, ortografia e necessidade de cada pergunta para o questionário. As alterações pertinentes foram realizadas, revisadas e novamente discutidas. A primeira versão foi apresentada a 10 pacientes que não participaram das entrevistas qualitativas e responderam o grau de entendimento e necessidade de cada pergunta. A análise final do pré-teste reformulou alguns tempos verbais e palavras de difícil compreensão, dando forma a versão final do instrumento. Discussão: Embora existam bons instrumentos para mensurar QV e mucosite oral, apresentamos novas questões sobre impactos financeiros, interrupção de tratamento, alteração de saliva, perda de peso relacionada diretamente com a mucosite oral e aspectos psicossociais. Conclusão: Foi elaborado um novo instrumento para mensurar os impactos mucosite oral em pacientes oncológicos.


Assuntos
Qualidade de Vida , Estomatite , Inquéritos e Questionários , Instrumentos Odontológicos
12.
Eur Endod J ; 9(2): 133 - 138, 2024 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-38268112

RESUMO

OBJECTIVE: To evaluate the impact of different file access angles and root canal curvature's location on the fatigue failure of One Curve (OC) and E3 Azure (EZ) NiTi files using a dynamic model at simulated body temperature. METHODS: Eighty new instruments with similar tip sizes and taper (#25/0.06) from two NiTi rotary systems, One Curve and E3 Azure, were tested at simulated body temperatures (37°C) using a custom-made dynamic cyclic fatigue device. Instruments were divided into four subgroups according to the location of root canal curvature (a coronal curve 5 mm from the root canal orifice and an apical curve 10 mm from the root canal orifice) and the angle of file access (0° or 30°). Instruments were operated in simulated stainless-steel canals having a 60° curve and a 3 mm radius. A custom-made device produced controlled vertical pecks during file rotation. Time to failure (sec) was registered, and the length of the fragment segments was measured (mm). Data were analysed statistically with One-Way ANOVA and Tukey post hoc tests. The significance level was set at 5%. All separated instruments were examined by scanning electron microscope. RESULTS: One-way ANOVA (p<0.05) found a significant difference among the tested instruments. Post Hoc analysis revealed lower cyclic fatigue resistance when the angle of file access was 30º, and the root canal curvature was located coronally for both files (p<0.0001). Three-way ANOVA showed that the angle of file access was the most influential contributor to cyclic fatigue, followed by the location of file curvature and, finally, the file type (p<0.0001). The fractographic examination revealed a predominantly ductile fracture mode for all tested instruments. The lengths of all fractured segments showed no significant difference (p>0.05), indicating an accurate trajectory during testing. CONCLUSION: OC files had superior cyclic fatigue resistance than EZ files; coronal curvatures negatively impacted cyclic fatigue resistance compared to apical curvatures, while the angle of file access presented the highest impact on dynamic cyclic fatigue.


Assuntos
Ligas , Ligas Dentárias , Instrumentos Odontológicos , Níquel , Titânio , Falha de Equipamento , Preparo de Canal Radicular
14.
J Endod ; 50(2): 213-219, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37924940

RESUMO

INTRODUCTION: The aim of this study was to evaluate the torsional resistance, cyclic fatigue resistance, and bending stiffness of nickel-titanium (NiTi) file systems with different heat treatments and cross-sectional designs. METHODS: WaveOne Primary treated with memory-triple (MT) heat treatment (WOMT) was compared with WaveOne Primary (WO) and WaveOne Gold Primary (WOG). Torsional resistance test was performed using a customized device, and the distortion angle, ultimate strength, and toughness were evaluated. For cyclic fatigue resistance test, the instruments were reciprocated with continuous 4 mm up-and-down movement until fracture in a customized device, and the time to fracture was compared. Fracture surfaces of each group were examined under the scanning electron microscope. Bending stiffness was measured using a custom-made device. The results were analyzed using one-way analysis of variance and the Tukey's post hoc comparison at a significance level of 95%. RESULTS: WOMT showed higher ultimate strength and toughness than the other systems (P < .05). WOMT also showed highest cyclic fatigue resistance among the tested groups (P < .05). WO had the highest bending stiffness than others, whereas WOMT had a larger residual angle than others (P < .05). CONCLUSIONS: This new MT heat treatment technique makes NiTi file more flexible and improves its mechanical properties. In addition, the effect of heat treatment on flexibility was found to be more significant than that of the cross-sectional area.


Assuntos
Ligas , Temperatura Alta , Titânio , Níquel , Instrumentos Odontológicos , Desenho de Equipamento , Preparo de Canal Radicular , Estresse Mecânico , Teste de Materiais , Torção Mecânica
15.
Int Endod J ; 57(1): 100-107, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37886883

RESUMO

AIM: This study compared intracanal removal of filling as well as the frequency and volume of extruded material after retreatment with either HyFlex or Reciproc instruments in mandibular teeth from cadavers. METHODOLOGY: The root canals of 14 pairs of contralateral single-rooted teeth in mandibles of cadavers were instrumented with Reciproc R40 and filled using lateral compaction. The mandibles were scanned in a micro-computed tomographic (micro-CT) device before and after retreatment procedures. The contralateral teeth were assigned to two groups (n = 14) according to the retreatment protocol using either HyFlex or Reciproc instrument systems. In the HyFlex group, the HyFlex Remover instrument was worked 3 mm short of the working length (WL), followed by HyFlex CM 40.04 and 50.04 at the WL. In the Reciproc group, the R50 instrument was worked up at the coronal two thirds, followed by two more cycles until the WL was reached. Pre- and post-operative micro-CT images were analysed for extrusion and intracanal removal of filling material. RESULTS: After retreatment, extrusion of filling material occurred in 11 (78%) and 14 (100%) teeth from HyFlex and Reciproc groups respectively (p > .05). A similar volume of extruded material was observed after retreatment with both systems (p > .05). A significant decrease in the intracanal filling volume was verified after retreatment with both tested systems (p < .05). However, residual filling material was found in all root canals, regardless of the system. The amount of filling material removed (HyFlex = 80.8%; Reciproc = 65.9%) and the operation time was similar between systems (p > .05). CONCLUSIONS: A high frequency of filling material extrusion was observed after retreatment with the two systems in a cadaver model, with no significant difference between them. Both protocols obtained similar efficacy in filling material removal procedures, although none completely cleaned the canals.


Assuntos
Materiais Restauradores do Canal Radicular , Humanos , Guta-Percha , Obturação do Canal Radicular , Preparo de Canal Radicular , Instrumentos Odontológicos , Retratamento , Microtomografia por Raio-X/métodos , Cavidade Pulpar
16.
Artigo em Inglês | MEDLINE | ID: mdl-38082736

RESUMO

Dentistry is an essential practice to maintain the health of the oral cavity. Recent advances in digitization and technology for oral examinations have improved the speed and ease of disease diagnosis and dental treatment. Dental robotics has emerged as a new field of dentistry and offers numerous benefits to dental professionals and society. This paper proposes an innovative design of a dental robot setup with a preliminary study on a head model for the preparation of automated dental exploration in MATLAB and discusses further considerations for automation.


Assuntos
Robótica , Humanos , Automação , Instrumentos Odontológicos , Assistência Odontológica
17.
J Contemp Dent Pract ; 24(5): 337-341, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38149812

RESUMO

AIM: This in vitro study aimed to compare and evaluate the resistance to cyclic fatigue of a newly developed glide path file in a simulated double curvature canal in a cyclic fatigue-testing machine. METHODS: In this in vitro study, a static cyclic fatigue-testing machine with a simulated double curve was created and the samples were divided into the following three groups: Group I-HyFlex EDM; group II-TruNatomy file; and group III-Aurum G files and each instrument is continued to rotate in the canal and a number of cycles to failure (NCF) was calculated and Fractographic analysis was done using scanning electron microscope (SEM), and the results were statistically analyzed. RESULTS: Statistical analysis was done using parametric methods one-way analysis of variance (ANOVA) shows statistical significance between groups and then Tukey's HSD post hoc tests were used for multiple pairwise comparisons. TruNatomy glide path files had the highest cyclic fatigue resistance when compared to HyFlex EDM and Aurum G files. CONCLUSION: The selection of file systems in cleaning and shaping protocols is an enigma to endodontics. From the results of this study, it can be concluded that TruNatomy files had higher cyclic fatigue resistance than other glide path files are canals with double curvature, hence it is suitable for usage in root canals with extreme curvature. CLINICAL SIGNIFICANCE: The selection of file systems in cleaning and shaping protocols is an enigma to endodontics. This in vitro study explored the selection protocols for the execution of root canal preparation. Heat treatment of nickel-titanium (NiTi) endodontic files had improved the cyclic fatigue resistance significantly enhancing the clinical life of file systems.


Assuntos
Projetos de Pesquisa , Titânio , Preparo de Canal Radicular , Instrumentos Odontológicos , Falha de Equipamento
19.
J Contemp Dent Pract ; 24(9): 715-721, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38152947

RESUMO

AIM: This research was carried out with the objective of comparison between GenEndo, Protaper Gold, Hero Gold and EdgeFile X3 regarding the effect of different concentrations of NaOCl. MATERIALS AND METHODS: About 720 study specimens were included in the study. They were divided into four groups. Each group consisted of 180 files. Group A: GenEndo, Group B: Protaper Gold, Group C: Hero Gold, Group D: EdgeFile X3. Each group of instruments were further subdivided into nine subgroups (n = 20 for each subgroup). Testing of the cyclic fatigue was carried out in artificial canals which were prepared inside the blocks of stainless steel. The stainless steel blocks with artificial canals were established in a receiver that was packed with experimental solutions like distilled water, 5.25% NaOCl and 2.5% NaOCl. The adjustment of temperature was done at 25, 37, and 60°C. The rotation of the instrument was carried out inside the artificial canal as per the instructions of the manufacturer. The instrument was rotated until it got fractured. The time taken by the instrument to fracture was recorded in seconds. The number of cycles to fracture (NCF) was analyzed with the help of the equation (NCF = time to fracture × rpm/60). Surfaces at the site of fracture were examined with the help of a scanning electron microscope (EVOLS10, ZEISS) at magnification (300x and 2000x). RESULTS: It was noticed that there was a statistically significant increase in cyclic fatigue when sodium chloride was used as an endodontic irrigant instead of distilled water. The increase in cyclic fatigue was also observed when 5.25% sodium chloride was used instead of 2.5% sodium hypochlorite. Cyclic fatigue increased on change in temperature from 25 to 37°C and from 37 to 60°C. The difference was statistically significant (p < 0.05). It was observed that resistance against cyclic fatigue on treatment with different irrigation solutions at different temperatures was in the order of GenEndo > Protaper Gold > Hero Gold > EdgeFile X3. CONCLUSION: The resistance against cyclic fatigue in new NiTi rotary files can be affected significantly by different concentrations of sodium hypochlorite irrigant solution and the GenEndo rotary endodontic instrument has the maximum resistance against cyclic fatigue. CLINICAL SIGNIFICANCE: Irrigation of the root canal with irrigants, such as sodium hypochlorite (NaOCl) has been recommended strongly. NaOCl is used in the range of 0.5 and 6.5% concentration owing to its antimicrobial activity and tissue dissolution activities, particularly at higher temperatures. It has been postulated that fatigue of rotary endodontic instruments can be influenced by adjoining medium and their concentration.


Assuntos
Instrumentos Odontológicos , Falha de Equipamento , Teste de Materiais , Preparo de Canal Radicular , Cloreto de Sódio , Hipoclorito de Sódio , Aço Inoxidável , Temperatura , Titânio , Água
20.
Aust Dent J ; 68 Suppl 1: S24-S38, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37960998

RESUMO

The introduction of nickel-titanium (NiTi) mechanical instruments dramatically changed clinical endodontics over the last few decades. Before NiTi, it was necessary to use more instruments to create an ideal root canal shape, and many approaches, sequences and techniques were developed over the years. Recently, NiTi endodontic instruments have undergone a series of changes brought about by modifications in design, surface treatments, and thermal treatments to improve their root canal preparation outcomes and reduce associated canal preparation risks during root canal treatment. Heat treatment is one of the most fundamental approaches to improving the fatigue resistance and flexibility of NiTi endodontic instruments. In addition, new kinematics have been developed to offer greater safety and efficiency. This narrative review describes the general properties and manufacturing of NiTi instruments, and the mechanical system evolution of NiTi instruments.


Assuntos
Ligas Dentárias , Preparo de Canal Radicular , Humanos , Preparo de Canal Radicular/métodos , Níquel , Titânio , Desenho de Equipamento , Teste de Materiais , Instrumentos Odontológicos
SELEÇÃO DE REFERÊNCIAS