Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 947
Filtrar
1.
Radiol Imaging Cancer ; 6(3): e230211, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38727566

RESUMO

The "puffed cheek" technique is routinely performed during CT neck studies in patients with suspected oral cavity cancers. The insufflation of air within the oral vestibule helps in the detection of small buccal mucosal lesions, with better delineation of lesion origin, depth, and extent of spread. The pitfalls associated with this technique are often underrecognized and poorly understood. They can mimic actual lesions, forfeiting the technique's primary purpose. This review provides an overview of the puffed cheek technique and its associated pitfalls. These pitfalls include pneumoparotid, soft palate elevation that resembles a nasopharyngeal mass, various tongue displacements or distortions that obscure tongue lesions or mimic them, sublingual gland herniation, an apparent exacerbation of the airway edema, vocal cord adduction that hinders glottic evaluation, and false indications of osteochondronecrosis in laryngeal cartilage. Most stem from a common underlying mechanism of unintentional Valsalva maneuver engaged in by the patient while trying to perform a puffed cheek, creating a closed air column under positive pressure with resultant surrounding soft-tissue displacement. These pitfalls can thus be avoided by instructing the patient to maintain continuous nasal breathing while puffing out their cheek during image acquisition, preventing the formation of the closed air column. Keywords: CT, Head/Neck © RSNA, 2024.


Assuntos
Bochecha , Tomografia Computadorizada por Raios X , Humanos , Bochecha/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Neoplasias Bucais/diagnóstico por imagem , Insuflação/métodos
2.
Zhonghua Yi Xue Za Zhi ; 104(17): 1493-1498, 2024 May 07.
Artigo em Chinês | MEDLINE | ID: mdl-38706056

RESUMO

Objective: To investigate the effect and safety of transnasal humidified rapid insufflation ventilatory exchange (THRIVE) technique in hysteroscopic diagnostic and therapeutic surgery. Methods: This study was a randomized controlled trial. A total of 100 female patients undergoing hysteroscopy surgery at Beijing Tongren Hospital from September to December 2023 were selected and randomly divided into two groups by the random number table method: the THRIVE group and the mask oxygen group, with 50 patients in each group. Patients in both groups were given total intravenous anesthesia with propofol combined with remifentanil and preserved spontaneous respiration. The THRIVE group was given oxygen by the THRIVE device with an oxygen flow rate of 50 L/min, while the mask oxygen group was given oxygen by the mask with an oxygen flow rate of 5 L/min; the oxygen concentration of both groups was set at 100%. The general condition of the patients, vital signs during the operation, the amount of anesthesia drugs used and the operation time were recorded. The primary observation index was the incidence of hypoxic events in the two groups; the secondary observation indexes were the incidence and time of intraoperative apnea as well as the corresponding oxygenation interventions and the incidence of non-hypoxic adverse events. Results: The age of the THRIVE group was (42±14) years, and the age of the mask oxygen group was (43±15) years. The duration of surgery in the THRIVE group was (15.9±3.4) min, which was statistically lower than that of the mask oxygen group (16.3±4.5) min (P=0.041), and there were no differences observed in the duration of awakening time and anesthesia time (both P>0.05). There was no significant difference in the dosage of propofol, remifentanil, and intraoperative vasoactive drugs between the two groups (all P>0.05). The SpO2 of the patients in the THRIVE group at the end of the operation was (99.7±1.1) %, which was higher than that of the mask-oxygen group (99.1±1.1) % (P<0.05). There was no difference in SpO2 of the two groups at the other time points (all P>0.05). There were no differences in HR and MAP of two group patients at each time point (all P>0.05). The incidence of hypoxic events in the THRIVE group was 12.0% (6/50), which was lower than that of 28.0% (14/50) in the mask oxygen group (P=0.045). The difference in the incidence and duration of apnea between the two groups was not statistically significant (all P>0.05). There were no cases of temporary need for laryngeal mask or tracheal intubation during surgery in both groups. There was no statistically significant difference in the incidence of intraoperative body movement, dizziness, nausea and vomiting between the two groups (all P>0.05), and no cardiac, cerebral, renal or other important organ insufficiency occurred in the two weeks after surgery. Conclusion: THRIVE technology can provide effective oxygenation for patients undergoing hysteroscopic diagnosis and treatment, maintain patients' circulatory stability, and improve the safety and efficiency of surgery.


Assuntos
Histeroscopia , Humanos , Feminino , Adulto , Histeroscopia/métodos , Insuflação/métodos , Pessoa de Meia-Idade , Oxigênio , Remifentanil/administração & dosagem , Hipóxia , Propofol/administração & dosagem , Apneia
3.
PLoS One ; 19(5): e0302239, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38696429

RESUMO

BACKGROUND: Mechanical insufflation-exsufflation (MI-E) facilitates extubation. However, its potential to reduce the duration of ventilator use remains unclear. Therefore, the present study investigated whether the use of MI-E shortened the duration of mechanical ventilation in patients with high sputum retention. METHODS: A randomized open-label trial was conducted at a single intensive care unit (ICU) in Japan between November 2017 and June 2019. Ventilated subjects requiring suctioning at least once every hour due to sputum retention were randomly assigned to the MI-E group or conventional care group. The primary endpoint was the number of ventilator-free days on day 28. Secondary endpoints were ventilator days in surviving subjects, the length of ICU stay, and mortality and tracheostomy rates among survivors. RESULTS: Forty-eight subjects (81% males) with a median age of 72 years (interquartile range [IQR], 65-85 years) were enrolled. There were 27 subjects in the MI-E group and 21 in the control group. The median number of ventilator-free days was 21 (IQR, 13-24) and 18, respectively (IQR, 0-23) (P = .38). No significant differences were observed in the ICU length of stay (median, 10 days (IQR, 7-12) vs 12 days (IQR, 6-15); P = .31), mortality rate (19% vs 15%; odds ratio [OR], 1.36 [0.28-6.50]; P = .69), or tracheostomy rate among survivors (14% vs 28%; OR, 0.40 [0.08-1.91]; P = .25). CONCLUSION: In ventilated subjects in the ICU with high sputum retention, the use of MI-E did not significantly increase the number of ventilator-free days over that with conventional care.


Assuntos
Insuflação , Unidades de Terapia Intensiva , Tempo de Internação , Respiração Artificial , Escarro , Humanos , Masculino , Feminino , Idoso , Respiração Artificial/métodos , Idoso de 80 Anos ou mais , Insuflação/métodos , Traqueostomia , Japão , Pessoa de Meia-Idade
4.
J Robot Surg ; 18(1): 185, 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38683478

RESUMO

Little is known about the effects of CO2 insufflation (CDI) on cerebral oxygen saturation (CrSO2) during laparoscopy in the pediatric population. In children undergoing robotic-assisted laparoscopic pyeloplasty (RALP), we prospectively assessed the effects of CDI using standard monitoring and cerebral near-infrared spectroscopy (NIRS). We also explored whether a correlation existed between CrSO2 and parameters known to affect cerebral blood flow. Between January 2021 and September 2023, a cohort of consecutive children older than 2 years underwent RALP at Necker-Enfants Malades Hospital in Paris. A ventilation protocol aimed to prevent hypercarbia was implemented. Data collected included standard monitoring parameters and CrSO2 by NIRS. Thirty patients (16 females), mean age 5.5 ± 3.9 (2.0-9.5) years, were included. Twenty-three patients underwent a retroperitoneal approach. The mean baseline CrSO2 value was 83.0 ± 9.8. Mean CrSO2 decreased during progressive CDI, never below baseline values, while standard-monitoring parameters did not significantly change. No significant correlation was detected between CrSO2 and end tidal CO2, or between CrSO2 and mean arterial pressure, at any operative time. During RALP, a gradual CDI doesn't cause pathological derangements of CrSO2. The lack of correlation between CrSO2 and standard parameters affecting cerebral blood flow suggests the likely presence of cerebral autoregulation in our population.


Assuntos
Dióxido de Carbono , Laparoscopia , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Laparoscopia/métodos , Criança , Feminino , Masculino , Pré-Escolar , Circulação Cerebrovascular/fisiologia , Insuflação/métodos , Saturação de Oxigênio , Estudos Prospectivos , Espectroscopia de Luz Próxima ao Infravermelho/métodos
5.
Eur J Pharm Sci ; 197: 106775, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38643941

RESUMO

Research on pharmaceutical dry powders has been increasing worldwide, along with increased therapeutic strategies for an application through the pulmonary or the nasal routes. In vitro methodologies and tests that mimic the respiratory environment and the process of inhalation itself are, thus, essential. The literature frequently reports cell-based in vitro assays that involve testing the dry powders in suspension. This experimental setting is not adequate, as both the lung and the nasal cavity are devoid of abundant liquid. However, devices that permit powder insufflation over cells in culture are either scarce or technically complex and expensive, which is not feasible in early stages of research. In this context, this work proposes the development of a device that allows the delivery of dry powders onto cell surfaces, thus simulating inhalation more appropriately. Subsequently, a quartz crystal microbalance (QCM) was used to establish a technique enabling the determination of dry powder deposition profiles. Additionally, the determination of the viability of respiratory cells (A549) after the insufflation of a dry powder using the developed device was performed. In all, a prototype for dry powder insufflation was designed and developed, using 3D printing methods for its production. It allowed the homogenous dispersion of the insufflated powders over a petri dish and a QCM crystal, and a more detailed study on how dry powders disperse over the supports. The device, already protected by a patent, still requires further improvement, especially regarding the method for powder weighing and the efficiency of the insufflation process, which is being addressed. The impact of insufflation of air and of locust bean gum (LBG)-based microparticles revealed absence of cytotoxic effect, as cell viability roughly above 70 % was always determined.


Assuntos
Sobrevivência Celular , Inaladores de Pó Seco , Insuflação , Pós , Insuflação/métodos , Insuflação/instrumentação , Inaladores de Pó Seco/métodos , Inaladores de Pó Seco/instrumentação , Humanos , Sobrevivência Celular/efeitos dos fármacos , Administração por Inalação , Células A549 , Técnicas de Microbalança de Cristal de Quartzo/métodos , Impressão Tridimensional , Tamanho da Partícula , Desenho de Equipamento
6.
PLoS One ; 19(4): e0302626, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38687743

RESUMO

PURPOSE: To further identify the effectiveness of trans-nasal humidified rapid insufflation ventilatory exchange (THRIVE) for pre- and apneic oxygenation during the anesthesia induction by comparison to facemask ventilation (FMV) based on current available evidence. METHODS: Medline, EMBASE, Web of Science, Cochrane Library and CNKI databases were searched from inception to December 22, 2023 for available randomized controlled trials (RCTs). Primary outcomes were PaO2 and PaCO2 after intubation and safe apnoea time. Secondary outcomes included the O2 desaturation, end expiratory carbon dioxide (EtCO2) and complications. The effect measures for continuous and categorical outcomes were separately the mean difference (MD) and relative risk (RR) with 95% confidence interval. RESULTS: Twelve RCTs with 403 patients in the THRIVE group and 401 patients in th FMV group were included. Pooled results demonstrated that the PaO2 after intubation was significantly higher (MD = 82.90mmHg, 95% CI: 12.25~153.54mmHg, P = 0.02) and safe apnoea time (MD = 103.81s, 95% CI: 42.07~165.56s, P = 0.001) was longer in the THRIVE group. Besides, the incidence rate of O2 desaturation (RR = 0.28, 95% CI: 0.12-0.66, P = 0.004) and gastric insufflation (RR = 0.26, 95% CI: 0.13-0.49, P<0.001) was significantly lower in the THRIVE group. CONCLUSION: Based on current evidence, THRIVE manifested better effectiveness representing as improved oxygenation, prolonged safe apnoea time and decreased risk of complications compared to standard FMV in surgical patients. Therefore, THRIVE could be served as a novel and valuable oxygenation technology for patients during anesthesia induction.


Assuntos
Apneia , Insuflação , Ensaios Clínicos Controlados Aleatórios como Assunto , Humanos , Insuflação/métodos , Apneia/terapia , Máscaras , Oxigênio/metabolismo , Anestesia/métodos , Dióxido de Carbono , Respiração Artificial/métodos , Oxigenoterapia/métodos
7.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38489838

RESUMO

This clinical case shows the repercussions of acute exposure to cement dust in the respiratory tract and other mucous membranes. Following a cement dust pipe explosion, the patient endured a severe inhalation of dust. A combination of rigid bronchoscopy and a mechanical insufflation-exsufflation system was employed to remove cement debris from the airways. Respiratory physiotherapy sessions were implemented for effective secretion clearance, contributing to a successful short-term recovery. While this remains an isolated case, the unconventional techniques employed provide valuable insights for potential similar scenarios in the future.


Assuntos
Insuflação , Humanos , Insuflação/métodos , Broncoscopia , Respiração Artificial , Terapia Respiratória/métodos , Modalidades de Fisioterapia , Tosse
8.
BMJ Open Respir Res ; 11(1)2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38460974

RESUMO

INTRODUCTION: Patients with neuromuscular disease often have a weak and ineffective cough due to respiratory muscle weakness. One treatment option is mechanical insufflation-exsufflation (MI-E), also known as cough assist, which is known to increase cough strength. However, some patients have a laryngeal response to MI-E, which can make the treatment ineffective. Currently, the only method for assessing this is via nasal endoscopy while using MI-E. Some MI-E devices have onboard secure data (SD) cards, which allow the visualisation of waveforms. We hypothesise that the waveforms can be used to identify laryngeal responses to the MI-E. METHODS AND ANALYSIS: Participants will complete baseline assessments of spirometry, peak cough flow and sniff nasal inspiratory pressure. A nasal endoscope will be used to visualise the larynx during simultaneous MI-E via a mask with a drilled hole. MI-E will be delivered by an experienced physiotherapist. Four cycles of MI-E at a range of prescriptions will be delivered. MI-E waveforms will be downloaded into Care Orchestrator Essence software (Philips, Murraysville). Data will be collected prospectively and reviewed in a descriptive context, providing trends and potential rationales describing the waveforms in comparison to the nasal endoscope videos. ETHICS AND DISSEMINATION: This protocol has been reviewed by the East of England-Cambridge Central Research Ethics Committee, who have granted a favourable ethical opinion. The study opened to recruitment in January 2022 and aims to publish trial results in June 2024. TRIAL REGISTRATION NUMBER: NCT05189600.


Assuntos
Insuflação , Laringe , Humanos , Insuflação/métodos , Estudos de Coortes , Tosse , Algoritmos , Estudos Observacionais como Assunto
9.
Vet Surg ; 53(4): 613-619, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38380543

RESUMO

OBJECTIVE: The adverse effects of intra-abdominal pressure from capnoperitoneum on cardiovascular and pulmonary systems have been well documented, but the effects on portal pressures in dogs with various insufflation pressures is poorly defined. The aim of the present study was to measure the effect of a range of insufflation pressures on the portal pressure, using direct pressure measurements in patients undergoing laparoscopy. STUDY DESIGN: Clinical randomized prospective study. ANIMALS: Nine client-owned dogs undergoing routine laparoscopy. METHODS: Two rounds of direct portal pressure assessments were performed, at insufflation pressures of 0, 6, 10, and 14 mmHg in a predetermined randomized sequence. The data were analyzed for effects of insufflation pressure, hemodynamic alterations, and round. A best-fit exponential model of the relationship between portal pressure and insufflation pressure was created. RESULTS: Portal pressure increased by 38% at 6 mmHg, 95% at 10 mmHg, and 175% at 14 mmHg compared to baseline. Portal pressure increased at an average rate of 7.45% per mmHg of insufflation pressure. Effects of weight, weight/insufflation pressure interaction, and round of insufflation were not statistically significant. No systemic hemodynamic adverse events were observed. CONCLUSION: Portal pressure increased as insufflation pressure increased. There was no clinically significant difference in baseline portal pressure between rounds of insufflation. CLINICAL SIGNIFICANCE: This exponential model of portal pressure supports the use of the minimum insufflation pressure to allow visualization during laparoscopy. The return of portal pressure to baseline following desufflation supports the comparison of portal pressure measurements before and after laparoscopic shunt attenuation.


Assuntos
Insuflação , Laparoscopia , Animais , Cães , Laparoscopia/veterinária , Laparoscopia/métodos , Insuflação/veterinária , Insuflação/métodos , Masculino , Estudos Prospectivos , Feminino , Pressão na Veia Porta , Pneumoperitônio Artificial/veterinária , Pneumoperitônio Artificial/métodos
11.
Surg Laparosc Endosc Percutan Tech ; 34(1): 1-8, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37963307

RESUMO

BACKGROUND: High CO 2 pneumoperitoneum pressure during laparoscopy adversely affects the peritoneal environment. This study hypothesized that low pneumoperitoneum pressure may be linked to less peritoneal damage and possibly to better clinical outcomes. MATERIALS AND METHODS: One hundred patients undergoing scheduled laparoscopic cholecystectomy were randomized 1:1 to low or to standard pneumoperitoneum pressure. Peritoneal biopsies were performed at baseline time and 1 hour after peritoneum insufflation in all patients. The primary outcome was peritoneal remodeling biomarkers and apoptotic index. Secondary outcomes included biomarker differences at the studied times and some clinical variables such as length of hospital stay, and quality and safety issues related to the procedure. RESULTS: Peritoneal IL6 after 1 hour of surgery was significantly higher in the standard than in the low-pressure group (4.26±1.34 vs. 3.24±1.21; P =0.001). On the contrary, levels of connective tissue growth factor and plasminogen activator inhibitor-I were higher in the low-pressure group (0.89±0.61 vs. 0.61±0.84; P =0.025, and 0.74±0.89 vs. 0.24±1.15; P =0.028, respectively). Regarding apoptotic index, similar levels were found in both groups and were 44.0±10.9 and 42.5±17.8 in low and standard pressure groups, respectively. None of the secondary outcomes showed differences between the 2 groups. CONCLUSIONS: Peritoneal inflammation after laparoscopic cholecystectomy is higher when surgery is performed under standard pressure. Adhesion formation seems to be less in this group. The majority of patients undergoing surgery under low pressure were operated under optimal workspace conditions, regardless of the surgeon's expertise.


Assuntos
Colecistectomia Laparoscópica , Insuflação , Laparoscopia , Pneumoperitônio , Humanos , Peritônio/cirurgia , Colecistectomia Laparoscópica/efeitos adversos , Colecistectomia Laparoscópica/métodos , Pneumoperitônio/etiologia , Insuflação/efeitos adversos , Insuflação/métodos , Laparoscopia/métodos , Pneumoperitônio Artificial/efeitos adversos , Pneumoperitônio Artificial/métodos
12.
Respir Care ; 69(2): 227-237, 2024 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-37816542

RESUMO

Amyotrophic lateral sclerosis (ALS) is a rare, neurodegenerative motor neuron disease that affects voluntary muscle movement. Often, difficulty in coughing, breathing, and swallowing are sequela associated with the condition, and the presence of bulbar muscle predominant weakness results in deleterious effects on airway clearance and secretion management. This narrative review will provide practical guidance for clinicians treating this population. Cough insufficiency in this population typically manifests as a prolonged, slow, weak cough effort that impedes the clearability of secretions and airway protection. Dystussia and dysphagia frequently occur simultaneously in bulbar dysfunction, subsequently impacting respiratory health. Measures of respiratory strength should be obtained and monitored every 3-6 months, preferably in a multidisciplinary clinic setting. Cough augmentation, whether manual or mechanical techniques, should be sought as early in the disease progression as possible to adequately control secretions in the proximal airways. This airway clearance strategy can aid in the prevention and treatment of respiratory tract infections (RTIs), which can pose a significant clinical hurdle to those with ALS. The use of mechanical insufflation-exsufflation may be complicated by severe bulbar dysfunction rendering this technique ineffective. Though peripheral airway clearance strategies, such as high-frequency chest-wall compression, have the advantage of being less impacted by bulbar dysfunction, it is only recommended this modality be used in conjunction with, versus in lieu of, proximal strategies. Salivary secretion management includes the use of anticholinergics, botulinum toxin, and radiation therapy depending on severity and desire for relief.


Assuntos
Esclerose Lateral Amiotrófica , Oscilação da Parede Torácica , Insuflação , Insuficiência Respiratória , Humanos , Esclerose Lateral Amiotrófica/complicações , Esclerose Lateral Amiotrófica/terapia , Terapia Respiratória/métodos , Secreções Corporais , Insuflação/métodos , Tosse/etiologia , Insuficiência Respiratória/terapia
13.
J Endourol ; 38(1): 47-52, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37819689

RESUMO

Background: Conventional operative insufflation uses a one-way trocar to handle instruments while maintaining pneumoperitoneum. In 2007, the AirSeal® valveless trocar insufflation system was introduced, which maintains stable pneumoperitoneum while continuously evacuating smoke. Although this device has been validated in adult patients, it has not been extensively validated in the pediatric population. Materials and Methods: A retrospective cohort study of pediatric urology patients aged 0 to 21 who underwent laparoscopic pyeloplasty between March 2016 and October 2021 was performed. Intraoperative physiologic parameters, procedure characteristics, postoperative outcomes, and demographics of each patient in whom either AirSeal insufflation system (AIS) or conventional insufflation system (CIS) was utilized were obtained from hospital records. Data were compared across the AIS and CIS cohorts. The primary outcomes were intraoperative anesthetic and physiologic parameters, including end tidal carbon dioxide, oxygen saturation, body temperature, positive inspiratory pressure, systolic blood pressure, and heart rate. Results: There were no significant differences in the anesthetic and physiologic parameters in the AIS and CIS groups. In addition, no differences in demographics, procedural characteristics, or complication rates were found between the cohorts. Conclusion: The AirSeal valveless trocar insufflation system demonstrates comparable intraoperative anesthetic and physiologic outcomes compared to conventional one-way valve insufflation in pediatric laparoscopic pyeloplasty. Certain surgeon-related qualitative metrics are underappreciated in this study, however, including improved visualization with vigorous suctioning and pressure maintenance with frequent instrument exchanges. Surgeon experience may mask the benefits of these characteristics as it pertains to quantitative surgical outcomes such as estimated blood loss, operative time, and perioperative complications.


Assuntos
Anestésicos , Insuflação , Laparoscopia , Pneumoperitônio , Urologia , Adulto , Humanos , Criança , Insuflação/métodos , Estudos Retrospectivos , Laparoscopia/métodos , Instrumentos Cirúrgicos , Dióxido de Carbono , Pneumoperitônio Artificial/métodos
14.
Chest ; 165(4): 929-941, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37844796

RESUMO

BACKGROUND: Respiratory muscle weakness can impair cough function, leading to lower respiratory tract infections. These infections are an important contributor to morbidity and mortality in patients with neuromuscular disease. Mechanical insufflation-exsufflation (MIE) is used to augment cough function in these patients. Although MIE is widely used, there are few data to advise on the optimal technique. Since the introduction of MIE, the recommended pressures to be delivered have increased. There are concerns regarding the use of higher pressures and their potential to cause lung derecruitment and upper airway closure. RESEARCH QUESTION: What is the impact of high-pressure MIE (HP-MIE) on lung recruitment, respiratory drive, upper airway flow, and patient comfort, compared with low-pressure MIE (LP-MIE), in patients with respiratory muscle weakness? STUDY DESIGN AND METHODS: Clinically stable patients using domiciliary MIE with respiratory muscle weakness secondary to Duchenne muscle dystrophy, spinal cord injury, or long-term tracheostomy ventilation received LP-MIE (30/-30 cm H2O) and HP-MIE (60/-60 cm H2O) in a random sequence. Lung recruitment, neural respiratory drive, and cough peak expiratory flow were measured throughout, and patients reported comfort and breathlessness following each intervention. RESULTS: A total of 29 patients (10 with Duchenne muscle dystrophy, eight with spinal cord injury, and 11 with long-term tracheostomy ventilation) were included in this study. HP-MIE augmented cough peak expiratory flow compared with LP-MIE (mean cough peak expiratory flow HP-MIE 228 ± 81 L/min vs LP-MIE 179 ± 67 L/min; P = .0001) without any significant change in lung recruitment, neural respiratory drive, or patient-reported breathlessness. However, in patients with more pronounced respiratory muscle weakness, HP-MIE resulted in an increased rate of upper airway closure and patient discomfort that may have an impact on clinical efficacy. INTERPRETATION: HP-MIE did not lead to lung derecruitment or breathlessness compared with LP-MIE. However, it was poorly tolerated in individuals with advanced respiratory muscle weakness. HP-MIE generates more upper airway closure than LP-MIE, which may be missed if cough peak expiratory flow is used as the sole titration target. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov; No.: NCT02753959; URL: www. CLINICALTRIALS: gov.


Assuntos
Insuflação , Distrofia Muscular de Duchenne , Insuficiência Respiratória , Traumatismos da Medula Espinal , Humanos , Tosse , Dispneia , Insuflação/efeitos adversos , Insuflação/métodos , Distrofia Muscular de Duchenne/complicações , Respiração , Insuficiência Respiratória/etiologia , Traumatismos da Medula Espinal/complicações
15.
Ann Otol Rhinol Laryngol ; 133(3): 325-329, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38050852

RESUMO

OBJECTIVES: Transnasal humidified rapid insufflation ventilatory exchange (THRIVE) describes apneic oxygenation using humidified high flow nasal-cannula oxygen. Although it has been described as a sole mode of oxygenation in endoscopic laryngotracheal surgery, its use in endoscopic esophageal surgery under general anesthesia with neuromuscular paralysis has not previously been described. The objective of this study is to assess the safety and efficacy of THRIVE in esophagology. METHODS: We conducted a retrospective review of adult patients undergoing esophageal procedures under general anesthesia who were oxygenated using THRIVE at two academic institutions. Demographic, clinical, and anesthesiologic data were collected and analyzed. RESULTS: 14 cases performed from March 2021 to March 2022 met inclusion criteria. 13/14 (92.9%) of patients were able to maintain oxygenation throughout the entirety of their procedure. The mean apneic time was 17.9 minutes with a maximum of 32 minutes. One patient required "rescue" intubation due to failure to maintain oxygenation. Excluding the sole THRIVE failure, the median SpO2 at the conclusion of surgery was 99% (range 94-100%). A linear regression model yielded an increase in EtCO2 of 0.95 mmHg/min or 0.127 kPa/min. SpO2 was negatively associated with both tobacco pack-year smoking history (R2 = 0.343, P = .014) and BMI (R2 = 0.238, P = .038). CONCLUSION: THRIVE is a feasible, safe, and efficacious means of apneic oxygenation for patients undergoing esophageal endoscopic surgery under general anesthesia with neuromuscular paralysis, which may be particularly beneficial in patients with airway stenosis, as post-intubation changes can have severe clinical implications for this patient population. Obese patients and tobacco smokers may be at increased risk of oxygen desaturation when using THRIVE.


Assuntos
Insuflação , Adulto , Humanos , Insuflação/métodos , Administração Intranasal , Respiração Artificial/métodos , Oxigenoterapia , Paralisia , Oxigênio
16.
Colorectal Dis ; 26(1): 7-21, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37985859

RESUMO

BACKGROUND: Maintenance of normothermia is a crucial part of enhanced recovery after colorectal surgery. Dry-cold carbon dioxide (CO2 ) traditionally used for insufflation in laparoscopic surgery and negative pressure operating theatres has been associated with intraoperative hypothermia. Studies suggest that use of warmed-humidified CO2 may promote normothermia. However, due to a scarcity of high-quality studies demonstrating a proven benefit on intraoperative core body temperature, its use in colorectal surgery remains limited. Therefore, the aim of this review was to evaluate the effects of warmed-humidified CO2 compared to traditional dry-cold CO2 , or ambient air in operating theatres, during colorectal surgery. METHODS: A search of Medline, EMBASE, and CENTRAL was performed. Randomised controlled trials (RCTs) that compared patients receiving warmed-humidified CO2 with either dry-cold CO2 insufflation in laparoscopic procedures or no insufflation during open surgery were included. The primary outcome was change in intraoperative core body temperature. Secondary outcomes included length of stay, operating time, return of gastrointestinal function, wound infection, and postoperative pain. A pairwise meta-analysis was performed using inverse variance random effects. RESULTS: Among the six RCTs included, 208 patients received warmed-humidified CO2 (42.3% female, mean age: 65.8 years) and 210 patients received either dry-cold CO2 in laparoscopic procedures or no gas insufflation during open procedures (46.2% female, mean age: 66.1 years). No significant difference was found for change in intraoperative core body temperature (MD = 0.01, 95% CI: -0.1, 0.11, p = 0.90, very low certainty). Patients in the warmed-humidified CO2 group had significantly higher pain scores on postoperative day 1 (MD = 1.61, 95% CI: 0.91, 2.31, p < 0.05, very low certainty). No significant differences were found in any of the other secondary outcomes studied. CONCLUSION: Patients undergoing colorectal surgery receiving warmed-humidified CO2 do not experience any clinically meaningful difference in core body temperature change compared to their counterparts receiving dry-cold CO2 insufflation or no insufflation. However, patients may report greater pain scores on postoperative day 1 with warmed-humidified CO2 . There is likely no clinically important difference between warmed-humidified CO2 and dry-cold CO2 for patients undergoing colorectal surgery. Patient, clinician, and institution factors should be considered when deciding between these two insufflation modalities.


Assuntos
Cirurgia Colorretal , Insuflação , Laparoscopia , Feminino , Humanos , Idoso , Masculino , Dióxido de Carbono , Insuflação/métodos , Umidade , Laparoscopia/métodos , Dor Pós-Operatória/etiologia
17.
Rev. cuba. med ; 62(4)dic. 2023.
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1550899

RESUMO

Introducción: Las infecciones intestinales se relacionan con trastornos del sistema inmune y de la microbiota intestinal. Pueden ser recurrentes y producir otras alteraciones intestinales y sistémicas, que empeoran con la terapia antimicrobiana. La ozonoterapia ha sido usada en el tratamiento de infecciones intestinales. Objetivos: Recopilar información sobre los efectos biológicos, terapéuticos y la seguridad de la administración del ozono por insuflación rectal en el tratamiento de las infecciones intestinales. Métodos: Para la búsqueda de información se empleó el motor de búsqueda Google Académico. Se consultaron artículos en las bases de datos PubMed y SciELO de la Biblioteca Virtual de Salud. Además, se realizó una búsqueda general en los idiomas español e inglés, a partir de los artículos más relevantes acerca del estudio. Se utilizaron como palabras clave: infecciones, insuflación, microbioma gastrointestinal, ozono como términos más concretos. En el estudio no se aplicó ninguna restricción acerca del ámbito geográfico ni de la edad. Conclusiones: La aplicación rectal de ozono es segura, tiene acciones biológicas y terapéuticas útiles para tratar las infecciones intestinales. Actúa como inmunomodulador y protector de la microbiota intestinal, lo que permite enfrentar esta problemática de salud desde el punto de vista preventivo, curativo y de rehabilitación de los daños causados, tanto por los gérmenes como por los efectos de los antibióticos(AU)


Introduction: Intestinal infections are related to disorders of the immune system and intestinal microbiota. They can be recurrent and produce other intestinal and systemic alterations, which worsen with antimicrobial therapy. Ozone therapy has been used in the treatment of intestinal infections. Objectives: To compile information on the biological, therapeutic effects and safety of the administration of ozone by rectal insufflation in the treatment of intestinal infections. Methods: Google Scholar search engine was used for searching information. Articles were consulted in PubMed and SciELO databases of the Virtual Health Library. In addition, a general search was carried out in Spanish and English, based on the most relevant articles about the study. The keywords used were infections, insufflation, gastrointestinal microbiome, ozone as more specific terms. No restrictions on geographic area or age were applied in the study. Conclusions: The rectal application of ozone is safe, it has useful biological and therapeutic actions to treat intestinal infections, acting as an immunomodulator and protector of the intestinal microbiota, which allows us to face this health problem from a preventive, curative and rehabilitation point of view of the damage caused, both by germs and by the effects of antibiotics(AU)


Assuntos
Humanos , Ozônio/uso terapêutico , Insuflação/métodos , Microbioma Gastrointestinal/fisiologia , Infecções/tratamento farmacológico
18.
Surg Endosc ; 37(11): 8552-8561, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37794124

RESUMO

BACKGROUND: During minimal access surgery, surgical smoke is produced which can potentially be inhaled by the surgical team, leading to several health risks. This smoke can escape from the abdominal cavity into the operating room due to trocar leakage. The trocars and insufflator that are used during surgery influence gas leakage. Therefore, this study compares particle escape from a valveless (Conmed AirSeal iFS), and a conventional (Karl Storz Endoflator) system. MATERIALS AND METHODS: Using an in vitro model, a conventional and a valveless trocar system were compared. A protocol that simulated various surgical phases was defined to assess the surgical conditions and particle leakage. Insufflation pressures and instrument diameters were varied as these are known to affect gas leakage. RESULTS: The conventional trocar leaked during two distinct phases. Removal of the obturator caused a sudden release of particles. During instrument insertion, an average of 211 (IQR 111) particles per second escaped when using the 5 mm diameter instrument. With the 10 mm instrument, 50 (IQR 13) particles per second were measured. With the conventional trocar, a higher abdominal pressure increased particle leakage. The valveless trocar demonstrated a continuously high particle release during all phases. After the obturator was removed, particle escape increased sharply. Particle escape decreased to 1276 (IQR 580) particles per second for the 5 mm instrument insertion, and 1084 (IQR 630) particles per second for 10 mm instrument insertion. With the valveless trocar system, a higher insufflation pressure lowered particle escape. CONCLUSIONS: This study shows that a valveless trocar system releases more particles into the operating room environment than a conventional trocar. During instrument insertion, the leakage through the valveless system is 6 to 20 times higher than the conventional system. With a valveless trocar, leakage decreases with increasing pressure. With both trocar types leakage depends on instrument diameter.


Assuntos
Cavidade Abdominal , Insuflação , Laparoscopia , Humanos , Laparoscopia/métodos , Fumaça/efeitos adversos , Instrumentos Cirúrgicos , Insuflação/métodos
19.
Crit Care ; 27(1): 273, 2023 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-37420282

RESUMO

BACKGROUND: Airway opening pressure (AOP) detection and measurement are essential for assessing respiratory mechanics and adapting ventilation. We propose a novel approach for AOP assessment during volume assist control ventilation at a usual constant-flow rate of 60 L/min. OBJECTIVES: To validate the conductive pressure (Pcond) method, which compare the Pcond-defined on the airway pressure waveform as the difference between the airway pressure level at which an abrupt change in slope occurs at the beginning of insufflation and PEEP-to resistive pressure for AOP detection and measurement, and to compare its respiratory and hemodynamic tolerance to the standard low-flow insufflation method. METHODS: The proof-of-concept of the Pcond method was assessed on mechanical (lung simulator) and physiological (cadavers) bench models. Its diagnostic performance was evaluated in 213 patients, using the standard low-flow insufflation method as a reference. In 45 patients, the respiratory and hemodynamic tolerance of the Pcond method was compared with the standard low-flow method. MEASUREMENTS AND MAIN RESULTS: Bench assessments validated the Pcond method proof-of-concept. Sensitivity and specificity of the Pcond method for AOP detection were 93% and 91%, respectively. AOP obtained by Pcond and standard low-flow methods strongly correlated (r = 0.84, p < 0.001). Changes in SpO2 were significantly lower during Pcond than during standard method (p < 0.001). CONCLUSION: Determination of Pcond during constant-flow assist control ventilation may permit to easily and safely detect and measure AOP.


Assuntos
Insuflação , Humanos , Insuflação/métodos , Pulmão , Fenômenos Fisiológicos Respiratórios , Mecânica Respiratória , Respiração Artificial/métodos
20.
BMJ Open ; 13(7): e071273, 2023 07 17.
Artigo em Inglês | MEDLINE | ID: mdl-37460261

RESUMO

INTRODUCTION: Patients with neurological or neurosurgical disease can suffer from impaired cough, which may result in life-threatening retention of tracheobronchial secretions, atelectasis, pneumonia and finally death. Due to a lack of alternatives and pathophysiological plausibility, the application of mechanical insufflation-exsufflation (MI-E) has already become international standard care in neuromuscular disease and spinal cord injury although a lack of evidence for efficacy. High-quality studies to support the use of MI-E in neurological and neurosurgical patients during weaning from mechanical ventilation are missing. The goal of this exploratory study is to display the effect size of MI-E intervention on the duration of mechanical ventilation and additional outcomes. METHODS AND ANALYSIS: One hundred adult patients with a cough deficiency or retention of secretion admitted to a neurological intensive care unit (ICU) are planned to be recruited for this randomised controlled trial. Patients are randomised 1:1 to receive either MI-E or best standard care. Observation will take place until discharge from the hospital, death or end of the study period. The primary endpoint of this trial is the duration of mechanical ventilation from randomisation until successful weaning. The outcome will be analysed with Kaplan-Meier estimation and competing risks analyses. Secondary endpoint is the proportion of patients with successful weaning. Further outcomes will include the incidence of hospital-acquired pneumonia, mortality, decannulation rate, length of stay on the ICU and the total score of the Glasgow Coma Scale. ETHICS AND DISSEMINATION: The study was approved by the Medical Ethics Committee of the University of Oldenburg. The findings of this study will be submitted for publication in a peer-reviewed journal. TRIAL REGISTRATION NUMBER: DRKS00020981.


Assuntos
COVID-19 , Insuflação , Adulto , Humanos , Respiração Artificial , SARS-CoV-2 , Tosse/terapia , Insuflação/métodos , Desmame do Respirador/métodos , Sistema Nervoso Central , Ensaios Clínicos Controlados Aleatórios como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...