Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 91
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Molecules ; 25(13)2020 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-32605124

RESUMO

Multiwall carbon nanotube (CNT)-filled high density polyethylene (HDPE) nanocomposites were prepared by extrusion and considered for their suitability in the offshore sheathing applications. Transmission electron microscopy was conducted to analyse dispersion after bulk extrusion. Monolithic and nanocomposite samples were subjected to accelerated weathering and photodegradation (carbonyl and vinyl indices) characterisations, which consisted of heat, moisture (seawater) and UV light, intended to imitate the offshore conditions. The effects of accelerated weathering on mechanical properties (tensile strength and elastic modulus) of the nanocomposites were analysed. CNT addition in HDPE produced environmentally resilient nanocomposites with improved mechanical properties. The energy utilised to extrude nanocomposites was also less than the energy used to extrude monolithic HDPE samples. The results support the mass substitution of CNT-filled HDPE nanocomposites in high-end offshore applications.


Assuntos
Nanocompostos/química , Nanotubos de Carbono/química , Polietileno/química , Módulo de Elasticidade/efeitos dos fármacos , Módulo de Elasticidade/efeitos da radiação , Temperatura Alta/efeitos adversos , Teste de Materiais , Microscopia Eletrônica de Transmissão , Nanocompostos/efeitos da radiação , Nanotubos de Carbono/efeitos da radiação , Polietileno/efeitos da radiação , Água do Mar/efeitos adversos , Resistência à Tração/efeitos dos fármacos , Resistência à Tração/efeitos da radiação , Raios Ultravioleta/efeitos adversos
2.
Cell Biochem Biophys ; 77(2): 179-186, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30565023

RESUMO

Exposure to ionizing radiation is unavoidable for noncancerous cells during the external radiotherapy process. Increasing the dose delivery fraction times leads to increasing the endothelial cell damage. Vascular abnormalities are commonly associated with the alternation of endothelium biomechanical properties. The goal of the present study was to quantify the elastic and viscoelastic properties of human umbilical vein endothelial cells (HUVECs) using the micropipette aspiration technique in conjunction with a theoretical model while an 8 Gy dose was given in four fractions. Confocal imaging was performed for evaluation of cytoskeletal changes during fractionation 60Co radiotherapy. The results indicated an increase in elastic modulus from 29.87 ± 1.04 Pa to 46.69 ± 1.17 Pa while the fractional doses increased from 0 Gy to 8 Gy along with the obvious cytoskeletal changes. Moreover, in the creep behavior of radiated groups, a significant decrease was shown in the time constant and viscoelastic properties. On the other hand, it was observed that the change in the biomechanical properties of the cells while applying a single fraction of 8 Gy was not exactly the same as that in the properties of the radiation-exposed cells while delivering an 8 Gy dose at 2 Gy per fraction. The observed differences in the biomechanical behavior of endothelium provide a quantitative description of radiobiological effects for evaluating the dose-response relationship as a biological dosimetry procedure.


Assuntos
Módulo de Elasticidade/efeitos da radiação , Raios gama , Radioisótopos de Cobalto/química , Citoesqueleto/efeitos da radiação , Células Endoteliais da Veia Umbilical Humana , Humanos , Microscopia Confocal , Doses de Radiação
3.
Nanoscale ; 10(45): 21046-21051, 2018 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-30276394

RESUMO

Optogenetic techniques have changed the landscape of neuroscience by offering high temporal and spatial mapping of the activities of genetically defined population of cells with optical controlling tools. The mapping of optogenetic activities demands optogenetic indicators whose optical properties change in response to cellular activities, but the existing optogenetic indicators only specifically characterize limited optogenetic activities. Here, we propose a novel optogenetic indicator based on cellular deformation to characterize the activities of optogenetically engineered cells. The cellular activities triggered by light stimulation lead to changes in the cell membrane structure and result in cellular deformation, which is measured by atomic force microscopy. The deformation recordings of the cells expressing channelrhodopsin-2 (ChR2) and the corresponding control experiments together confirm that the deformation is generated generally when the cells are exposed to light, which is also validated indirectly via the change in the Young's modulus of the cells before and after absorption of photons. The activities of cells expressing different subtypes of opsins were also recorded using the optogenetic indicator of cellular deformation. This study provides a novel and general optogenetic indicator based on cellular deformation for monitoring the activities of optogenetically engineered cells. Moreover, this new optogenetic indicator offers ever-better tools for the applications of optogenetic activity mapping and neural and brain imaging.


Assuntos
Membrana Celular/química , Channelrhodopsins/metabolismo , Optogenética/métodos , Channelrhodopsins/genética , Módulo de Elasticidade/efeitos da radiação , Células HEK293 , Humanos , Luz , Microscopia de Força Atômica , Mutagênese Sítio-Dirigida , Optogenética/instrumentação
4.
Biomed Mater ; 11(1): 015011, 2016 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-26836023

RESUMO

The manufacture of 3D scaffolds with specific controlled porous architecture, defined microstructure and an adjustable degradation profile was achieved using two-photon polymerization (TPP) with a size of 2 × 4 × 2 mm(3). Scaffolds made from poly(D,L-lactide-co-ɛ-caprolactone) copolymer with varying lactic acid (LA) and ɛ -caprolactone (CL) ratios (LC16:4, 18:2 and 9:1) were generated via ring-opening-polymerization and photoactivation. The reactivity was quantified using photo-DSC, yielding a double bond conversion ranging from 70% to 90%. The pore sizes for all LC scaffolds were see 300 µm and throat sizes varied from 152 to 177 µm. In vitro degradation was conducted at different temperatures; 37, 50 and 65 °C. Change in compressive properties immersed at 37 °C over time was also measured. Variations in thermal, degradation and mechanical properties of the LC scaffolds were related to the LA/CL ratio. Scaffold LC16:4 showed significantly lower glass transition temperature (T g) (4.8 °C) in comparison with the LC 18:2 and 9:1 (see 32 °C). Rates of mass loss for the LC16:4 scaffolds at all temperatures were significantly lower than that for LC18:2 and 9:1. The degradation activation energies for scaffold materials ranged from 82.7 to 94.9 kJ mol(-1). A prediction for degradation time was applied through a correlation between long-term degradation studies at 37 °C and short-term studies at elevated temperatures (50 and 65 °C) using the half-life of mass loss (Time (M1/2)) parameter. However, the initial compressive moduli for LC18:2 and 9:1 scaffolds were 7 to 14 times higher than LC16:4 (see 0.27) which was suggested to be due to its higher CL content (20%). All scaffolds showed a gradual loss in their compressive strength and modulus over time as a result of progressive mass loss over time. The manufacturing process utilized and the scaffolds produced have potential for use in tissue engineering and regenerative medicine applications.


Assuntos
Implantes Absorvíveis , Ácido Láctico/química , Poliésteres/química , Polímeros/química , Impressão Tridimensional , Alicerces Teciduais , Força Compressiva/efeitos da radiação , Módulo de Elasticidade/efeitos da radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Luz , Teste de Materiais , Fótons , Polímeros/síntese química , Polímeros/efeitos da radiação , Estresse Mecânico , Resistência à Tração/efeitos da radiação , Engenharia Tecidual/instrumentação , Engenharia Tecidual/métodos
5.
Ultrasound Med Biol ; 42(4): 1010-7, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26777069

RESUMO

In this Technical Note, we determine the interfacial rheological parameters of the encapsulation of the contrast agent Targestar P using ultrasound attenuation. The characteristic parameters are obtained according to two interfacial rheological models. The properties-surface dilatational elasticity (0.09 ± 0.01 N/m) and surface dilatational viscosity (8 ± 0.1E-9 N·s/m)-are found to be of similar magnitude for both models. Contrast microbubbles experience different ambient pressure in different organs. We also measure these parameters as functions of ambient pressure using attenuation measured at different overpressures (0, 100 and 200 mm Hg). For each value of ambient hydrostatic pressure, we determine the rheological properties, accounting for changes in the size distribution caused by the pressure change. We discuss different models of size distribution change under overpressure: pure adiabatic compression or gas exchange with surrounding medium. The dilatational surface elasticity and viscosity are found to increase with increasing ambient pressure.


Assuntos
Cápsulas/química , Cápsulas/efeitos da radiação , Meios de Contraste/química , Fluorocarbonos/química , Fosfolipídeos/química , Pressão , Módulo de Elasticidade/efeitos da radiação , Fluorocarbonos/efeitos da radiação , Ondas de Choque de Alta Energia , Teste de Materiais , Tamanho da Partícula , Fosfolipídeos/efeitos da radiação , Doses de Radiação , Resistência ao Cisalhamento/efeitos da radiação , Propriedades de Superfície/efeitos da radiação , Viscosidade/efeitos da radiação
6.
Braz Oral Res ; 302016.
Artigo em Inglês | MEDLINE | ID: mdl-26676192

RESUMO

Radiotherapy for malignancies in the head and neck can cause common complications that can result in tooth damage that are also known as radiation caries. The aim of this study was to examine damage to the surface topography and calculate changes in friction behavior and the nano-mechanical properties (elastic modulus, nanohardness and friction coefficient) of enamel and dentine from extracted human third molars caused by exposure to radiation. Enamel and dentine samples from 50 human third molars were randomly assigned to four test groups or a control group. The test groups were exposed to high energy X-rays at 2 Gy/day, 5 days/week for 5 days (10 Gy group), 15 days (30 Gy group), 25 days (50 Gy group), 35 days (70 Gy group); the control group was not exposed. The nanohardness, elastic modulus, and friction coefficient were analyzed using a Hysitron Triboindenter. The nano-mechanical properties of both enamel and dentine showed significant dose-response relationships. The nanohardness and elastic modulus were most variable between 30-50 Gy, while the friction coefficient was most variable between 0-10 Gy for dentine and 30-50 Gy for enamel. After exposure to X-rays, the fracture resistance of the teeth clearly decreased (rapidly increasing friction coefficient with increasing doses under the same load), and they were more fragile. These nano-mechanical changes in dental hard tissue may increase the susceptibility to caries. Radiotherapy caused nano-mechanical changes in dentine and enamel that were dose related. The key doses were 30-50 Gy and the key time points occurred during the 15th-25th days of treatment, which is when application of measures to prevent radiation caries should be considered.


Assuntos
Esmalte Dentário/efeitos da radiação , Dentina/efeitos da radiação , Lesões por Radiação/etiologia , Radioterapia de Alta Energia/efeitos adversos , Análise de Variância , Cárie Dentária/etiologia , Esmalte Dentário/química , Dentina/química , Módulo de Elasticidade/efeitos da radiação , Fricção/efeitos da radiação , Dureza/efeitos da radiação , Humanos , Ilustração Médica , Doses de Radiação , Valores de Referência , Propriedades de Superfície/efeitos da radiação , Fatores de Tempo
7.
Braz. oral res. (Online) ; 30(1): e9, 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-768256

RESUMO

Abstract Radiotherapy for malignancies in the head and neck can cause common complications that can result in tooth damage that are also known as radiation caries. The aim of this study was to examine damage to the surface topography and calculate changes in friction behavior and the nano-mechanical properties (elastic modulus, nanohardness and friction coefficient) of enamel and dentine from extracted human third molars caused by exposure to radiation. Enamel and dentine samples from 50 human third molars were randomly assigned to four test groups or a control group. The test groups were exposed to high energy X-rays at 2 Gy/day, 5 days/week for 5 days (10 Gy group), 15 days (30 Gy group), 25 days (50 Gy group), 35 days (70 Gy group); the control group was not exposed. The nanohardness, elastic modulus, and friction coefficient were analyzed using a Hysitron Triboindenter. The nano-mechanical properties of both enamel and dentine showed significant dose-response relationships. The nanohardness and elastic modulus were most variable between 30-50 Gy, while the friction coefficient was most variable between 0-10 Gy for dentine and 30-50 Gy for enamel. After exposure to X-rays, the fracture resistance of the teeth clearly decreased (rapidly increasing friction coefficient with increasing doses under the same load), and they were more fragile. These nano-mechanical changes in dental hard tissue may increase the susceptibility to caries. Radiotherapy caused nano-mechanical changes in dentine and enamel that were dose related. The key doses were 30-50 Gy and the key time points occurred during the 15th-25th days of treatment, which is when application of measures to prevent radiation caries should be considered.


Assuntos
Humanos , Esmalte Dentário/efeitos da radiação , Dentina/efeitos da radiação , Lesões por Radiação/etiologia , Radioterapia de Alta Energia/efeitos adversos , Análise de Variância , Cárie Dentária/etiologia , Esmalte Dentário/química , Dentina/química , Módulo de Elasticidade/efeitos da radiação , Fricção/efeitos da radiação , Dureza/efeitos da radiação , Ilustração Médica , Doses de Radiação , Valores de Referência , Propriedades de Superfície/efeitos da radiação , Fatores de Tempo
8.
Radiat Res ; 184(6): 639-49, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26632857

RESUMO

Exposure of the lung to radiation produces injury and inflammatory responses that result in microenvironmental alterations, which can promote the development of pneumonitis and/or pulmonary fibrosis. It has been shown that after other toxic insults, macrophages become phenotypically polarized in response to microenvironmental signals, orchestrating the downstream inflammatory responses. However, their contribution to the development of the late consequences of pulmonary radiation exposure remains unclear. To address this issue, fibrosis-prone C57BL/6J mice or pneumonitis-prone C3H/HeJ mice were whole-lung irradiated with 0 or 12.5 Gy and lung digests were collected between 3 and 26 weeks after radiation exposure. CD45(+) leukocytes were isolated and characterized by flow cytometry, and alveolar, interstitial and infiltrating macrophages were also detected. Ly6C, expressed by pro-inflammatory monocytes and macrophages, and mannose receptor (CD206), a marker of alternative activation, were assessed in each subpopulation. While the total number of pulmonary macrophages was depleted at 3 weeks after lung irradiation relative to age-matched controls in both C57 and C3H mice, identification of discrete subpopulations showed that this loss in cell number occurred in the alveolar, but not the interstitial or infiltrating, subsets. In the alveolar macrophages of both C57 and C3H mice, this correlated with a loss in the proportion of cells that expressed CD206 and F4/80. In contrast, in interstitial and infiltrating macrophages, the proportion of cells expressing these markers was increased at several time points after irradiation, with this response generally more pronounced in C3H mice. Radiation exposure was also associated with elevations in the proportion of alveolar and interstitial macrophage subpopulations expressing Ly6C and F4/80, with this response occurring at earlier time points in C57 mice. Although the radiation dose used in this study was not isoeffective for the inflammatory response in the two strains, the differences observed in the responses of these discrete macrophage populations between the fibrosis-prone versus pneumonitis-prone mice nonetheless suggest a possible role for these cells in the development of long-term consequences of pulmonary radiation exposure.


Assuntos
Pulmão/citologia , Pulmão/fisiologia , Macrófagos/citologia , Macrófagos/fisiologia , Animais , Relação Dose-Resposta à Radiação , Módulo de Elasticidade/fisiologia , Módulo de Elasticidade/efeitos da radiação , Feminino , Pulmão/efeitos da radiação , Macrófagos/efeitos da radiação , Camundongos , Camundongos Endogâmicos C3H , Camundongos Endogâmicos C57BL , Doses de Radiação
9.
Biomed Mater Eng ; 25(4): 397-403, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26407201

RESUMO

The increased use of allograft tissue for musculoskeletal repair has brought more focus to the safety of allogenic tissue and the efficacy of various sterilization techniques. The currently available literature contains few examples of studies on long-lasting strains of bones but no example for irradiated bones. In this study the bovine femurs from a 2-year-old animal were machine cut and irradiated with the doses of 10, 15, 25, 35, 45 and 50 kGy. The dynamic mechanical analysis was performed at 1 Hz at the room temperature in a 3-point bending configuration for 2880 minutes. The final values of E' and E″ were dose independent but they were reached at different periods. For this reason, so called "critical point" was introduced for the further analysis. All the examined sample groups were characterized by statistically significant lower values of the critical point in comparison with the control samples (p<0.05) but the biggest differences were observed between the control samples and the samples irradiated with the doses of 10, 15 and 25 kGy. Current results and literature review suggest that the dose of 35 kGy is the optimal dose for ionizing radiation sterilization.


Assuntos
Adaptação Fisiológica/fisiologia , Fêmur/fisiologia , Fêmur/efeitos da radiação , Modelos Biológicos , Adaptação Fisiológica/efeitos da radiação , Animais , Transplante Ósseo/métodos , Bovinos , Força Compressiva/fisiologia , Força Compressiva/efeitos da radiação , Simulação por Computador , Relação Dose-Resposta à Radiação , Módulo de Elasticidade/fisiologia , Módulo de Elasticidade/efeitos da radiação , Fêmur/transplante , Técnicas In Vitro , Doses de Radiação , Esterilização/métodos , Estresse Mecânico , Resistência à Tração/fisiologia , Resistência à Tração/efeitos da radiação , Fatores de Tempo
10.
Sci Rep ; 5: 13163, 2015 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-26302783

RESUMO

Vesicle and cell rupture caused by large viscous stresses in ultrasonication is central to biomedical and bioprocessing applications. The flow-induced opening of lipid membranes can be exploited to deliver drugs into cells, or to recover products from cells, provided that it can be obtained in a controlled fashion. Here we demonstrate that differences in lipid membrane and vesicle properties can enable selective flow-induced vesicle break-up. We obtained vesicle populations with different membrane properties by using different lipids (SOPC, DOPC, or POPC) and lipid:cholesterol mixtures (SOPC:chol and DOPC:chol). We subjected vesicles to large deformations in the acoustic microstreaming flow generated by ultrasound-driven microbubbles. By simultaneously deforming vesicles with different properties in the same flow, we determined the conditions in which rupture is selective with respect to the membrane stretching elasticity. We also investigated the effect of vesicle radius and excess area on the threshold for rupture, and identified conditions for robust selectivity based solely on the mechanical properties of the membrane. Our work should enable new sorting mechanisms based on the difference in membrane composition and mechanical properties between different vesicles, capsules, or cells.


Assuntos
Fluidez de Membrana/efeitos da radiação , Microfluídica/métodos , Sonicação/métodos , Som , Lipossomas Unilamelares/química , Lipossomas Unilamelares/efeitos da radiação , Força Compressiva/efeitos da radiação , Módulo de Elasticidade/efeitos da radiação , Pressão , Resistência ao Cisalhamento/efeitos da radiação , Estresse Mecânico , Resistência à Tração/efeitos da radiação , Viscosidade/efeitos da radiação
11.
Appl Radiat Isot ; 103: 1-8, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26036440

RESUMO

The effects of fission gas pressure, uranium swelling and thermal contact conductance on the thermal-mechanical behavior of an annular target containing a low-enriched uranium foil (LEU) encapsulated in a nickel foil have been presented in this paper. The draw-plug assembly method is simulated to obtain the residual stresses, which are applied to the irradiation model as initial inputs, and the integrated assembly-irradiation process is simulated as an axisymmetric problem using the commercial finite element code Abaqus FEA. Parametric studies were performed on the LEU heat generation rate and the results indicate satisfactory irradiation performance of the annular target. The temperature and stress margins have been provided along with a discussion of the results.


Assuntos
Modelos Químicos , Condutividade Térmica , Urânio/química , Urânio/efeitos da radiação , Força Compressiva/efeitos da radiação , Simulação por Computador , Relação Dose-Resposta à Radiação , Módulo de Elasticidade/efeitos da radiação , Transferência de Energia/efeitos da radiação , Doses de Radiação , Resistência ao Cisalhamento/efeitos da radiação , Estresse Mecânico , Temperatura , Resistência à Tração/efeitos da radiação
12.
Biomed Microdevices ; 17(3): 9960, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25975600

RESUMO

For the fabrication of customized silicone rubber based implants, e.g. cochlear implants or electrocortical grid arrays, it is required to develop high speed curing systems, which vulcanize the silicone rubber before it runs due to a heating related viscosity drop. Therefore, we present an infrared radiation based cross-linking approach for the 3D-printing of silicone rubber bulk and carbon nanotube based silicone rubber electrode materials. Composite materials were cured in less than 120 s and material interfaces were evaluated with scanning electron microscopy. Furthermore, curing related changes in the mechanical and cell-biological behaviour were investigated with tensile and WST-1 cell biocompatibility tests. The infrared absorption properties of the silicone rubber materials were analysed with fourier transform infrared spectroscopy in transmission and attenuated total reflection mode. The heat flux was calculated by using the FTIR data, emissivity data from the infrared source manufacturer and the geometrical view factor of the system.


Assuntos
Interface Osso-Implante/efeitos da radiação , Sobrevivência Celular/efeitos dos fármacos , Impressão Tridimensional , Silicones/química , Silicones/efeitos da radiação , Animais , Módulo de Elasticidade/efeitos da radiação , Análise de Falha de Equipamento , Dureza/efeitos da radiação , Raios Infravermelhos , Teste de Materiais , Camundongos , Células NIH 3T3 , Desenho de Prótese , Borracha , Resistência à Tração/efeitos da radiação
13.
ACS Appl Mater Interfaces ; 7(20): 11002-6, 2015 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-25938381

RESUMO

Harnessing a natural power source such as the human body temperature or sunlight should realize ultimate low-power devices. In particular, macroscale and flexible actuators that do not require an artificial power source have tremendous potential. Here we propose and demonstrate electrically powerless polymer-based actuators operated at ambient conditions using a packaging technique in which the stimulating power source is produced by heat from the human body or sunlight. The actuating angle, force, and reliability are discussed as functions of temperature and exposure to sunlight. Furthermore, a wearable device platform and a smart curtain actuated by the temperature of human skin and sunlight, respectively, are demonstrated as the first proof-of-concepts. These nature-powered actuators should realize a new class of ultimate low-power devices.


Assuntos
Resinas Acrílicas/química , Fontes de Energia Bioelétrica , Temperatura Corporal , Monitorização Ambulatorial/instrumentação , Luz Solar , Transdutores , Resinas Acrílicas/efeitos da radiação , Ar , Módulo de Elasticidade/efeitos da radiação , Transferência de Energia , Desenho de Equipamento , Análise de Falha de Equipamento , Temperatura Alta , Humanos , Teste de Materiais , Resistência à Tração/efeitos da radiação
14.
Bioinspir Biomim ; 10(2): 026005, 2015 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-25822595

RESUMO

Highly mineralized biological materials such as nacre (mother of pearl), tooth enamel or conch shell boast unique and attractive combinations of stiffness, strength and toughness. The structures of these biological materials and their associated mechanisms are now inspiring new types of advanced structural materials. However, despite significant efforts, no bottom up fabrication method could so far match biological materials in terms of microstructural organization and mechanical performance. Here we present a new 'top down' strategy to tackling this fabrication problem, which consists in carving weak interfaces within a brittle material using a laser engraving technique. We demonstrate the method by fabricating and testing borosilicate glasses containing nacre-like microstructures infiltrated with polyurethane. When deformed, these materials properly duplicate the mechanisms of natural nacre: combination of controlled sliding of the tablets, accompanied with geometric hardening, strain hardening and strain rate hardening. The nacre-like glass is composed of 93 volume % (vol%) glass, yet 700 times tougher and breaks at strains as high as 20%.


Assuntos
Materiais Biomiméticos/síntese química , Vidro/química , Vidro/efeitos da radiação , Lasers , Nácar/química , Módulo de Elasticidade/efeitos da radiação , Dureza/efeitos da radiação , Teste de Materiais , Propriedades de Superfície/efeitos da radiação , Resistência à Tração/efeitos da radiação , Viscosidade/efeitos da radiação
15.
J Am Soc Echocardiogr ; 28(6): 718-26.e2, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25769666

RESUMO

BACKGROUND: There is growing interest in limb contrast-enhanced ultrasound (CEU) perfusion imaging for the evaluation of peripheral artery disease. Because of low resting microvascular blood flow in skeletal muscle, signal enhancement during limb CEU is prohibitively low for real-time imaging. The aim of this study was to test the hypothesis that this obstacle can be overcome by intermediate- rather than low-power CEU when performed with an acoustically resilient microbubble agent. METHODS: Viscoelastic properties of Definity and Sonazoid were assessed by measuring bulk modulus during incremental increases in ambient pressure to 200 mm Hg. Comparison of in vivo microbubble destruction and signal enhancement at a mechanical index (MI) of 0.1 to 0.4 was performed by sequential reduction in pulsing interval from 10 to 0.05 sec during limb CEU at 7 MHz in mice and 1.8 MHz in dogs. Destruction was also assessed by broadband signal generation during passive cavitation detection. Real-time CEU perfusion imaging with destruction-replenishment was then performed at 1.8 MHz in dogs using an MI of 0.1, 0.2, or 0.3. RESULTS: Sonazoid had a higher bulk modulus than Definity (66 ± 12 vs 29 ± 2 kPa, P = .02) and exhibited less inertial cavitation (destruction) at MIs ≥ 0.2. On in vivo CEU, maximal signal intensity increased incrementally with MI for both agents and was equivalent between agents except at an MI of 0.1 (60% and 85% lower for Sonazoid at 7 and 1.8 MHz, respectively, P < .05). However, on progressive shortening of the pulsing interval, Definity was nearly completely destroyed at MIs ≥ 0.2 at 1.8 and 7 MHz, whereas Sonazoid was destroyed only at 1.8 MHz at MIs ≥ 0.3. As a result, real-time CEU perfusion imaging demonstrated approximately fourfold greater enhancement for Sonazoid at an MI of 0.3 to 0.4. CONCLUSIONS: Robust signal enhancement during real-time CEU perfusion imaging of the limb is possible when using intermediate-power imaging coupled with a durable microbubble contrast agent.


Assuntos
Compostos Férricos/química , Fluorocarbonos/química , Ferro/química , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Óxidos/química , Imagem de Perfusão/métodos , Ultrassonografia/métodos , Animais , Velocidade do Fluxo Sanguíneo/fisiologia , Sistemas Computacionais , Meios de Contraste , Cães , Módulo de Elasticidade/efeitos da radiação , Compostos Férricos/efeitos da radiação , Fluorocarbonos/efeitos da radiação , Dureza/efeitos da radiação , Ferro/efeitos da radiação , Teste de Materiais , Camundongos , Camundongos Endogâmicos C57BL , Microbolhas , Músculo Esquelético/irrigação sanguínea , Óxidos/efeitos da radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Som , Viscosidade/efeitos da radiação
16.
Ultrasound Med Biol ; 41(5): 1432-45, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25724308

RESUMO

For successful in vivo contrast-enhanced ultrasound imaging (CEUS) and ultrasound molecular imaging, detailed knowledge of stability and acoustical properties of the microbubbles is essential. Here, we compare these aspects of lipid-coated microbubbles that have either 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC) or 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) as their main lipid; the other components were identical. The microbubbles were investigated in vitro over the frequency range 1-4 MHz at pressures between 10 and 100 kPa, and their response to the applied ultrasound was recorded using ultrahigh-speed imaging (15 Mfps). Relative to DPPC-coated microbubbles, DSPC-coated microbubbles had (i) higher acoustical stability; (ii) higher shell elasticity as derived using the Marmottant model (DSPC: 0.26 ± 0.13 N/m, DPPC: 0.06 ± 0.06 N/m); (iii) pressure amplitudes twice as high at the second harmonic frequency; and (iv) a smaller amount of microbubbles that responded at the subharmonic frequency. Because of their higher acoustical stability and higher non-linear response, DSPC-coated microbubbles may be more suitable for contrast-enhanced ultrasound.


Assuntos
1,2-Dipalmitoilfosfatidilcolina/química , Materiais Revestidos Biocompatíveis/química , Meios de Contraste/química , Dimiristoilfosfatidilcolina/química , Modelos Químicos , 1,2-Dipalmitoilfosfatidilcolina/efeitos da radiação , Materiais Revestidos Biocompatíveis/efeitos da radiação , Simulação por Computador , Meios de Contraste/efeitos da radiação , Dimiristoilfosfatidilcolina/efeitos da radiação , Relação Dose-Resposta a Droga , Módulo de Elasticidade/efeitos da radiação , Teste de Materiais , Microbolhas , Dinâmica não Linear , Doses de Radiação , Estresse Mecânico , Ondas Ultrassônicas , Viscosidade/efeitos da radiação
17.
Cell Tissue Bank ; 16(3): 467-75, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25589449

RESUMO

Sterilisation of allografts are a crucial step in ensuring safety and viability. Current sterilisation standards such as 25 kGy gamma irradiation (γ) can have adverse effects on the ultrastructure and biomechanical properties of allograft tissue. Supercritical CO2 (SCCO2) technology, represents an improved sterilisation process that potentially preserves tissue properties. This study aimed to test the effect of SCCO2 sterilisation on the biomechanical and histological properties of the meniscus and compare this to the current standard of γ. Thirty-two 18-month old ovine menisci were randomly assigned into three groups for sterilisation (SCCO2, γ and control). After treatment, biomechanical indentation testing (stiffness and stress relaxation) or histological analysis [percentage of void, cells and extracellular matrix (ECM) per slide] was undertaken. Both SCCO2 and gamma groups displayed an increase in stiffness and stress relaxation as compared to control, however, this difference was lesser in samples treated with SCCO2. No significant histological quantitative differences were detected between SCCO2 and control specimens. Gamma-treated samples demonstrated a significant increase in void and decrease in ECM. Interestingly, both treatment groups demonstrated a decreasing mean void and increasing ECM percentage when analysed from outer to inner zones. No significant differences were detected in all-endpoints when analysed by section. SCCO2 sterilisation represents a potential feasible alternative to existing sterilization techniques such as γ.


Assuntos
Aloenxertos/citologia , Aloenxertos/fisiologia , Meniscos Tibiais/citologia , Meniscos Tibiais/fisiologia , Esterilização/métodos , Aloenxertos/efeitos da radiação , Animais , Dióxido de Carbono/farmacologia , Tamanho Celular/efeitos dos fármacos , Tamanho Celular/efeitos da radiação , Força Compressiva/efeitos dos fármacos , Força Compressiva/fisiologia , Força Compressiva/efeitos da radiação , Módulo de Elasticidade/efeitos dos fármacos , Módulo de Elasticidade/fisiologia , Módulo de Elasticidade/efeitos da radiação , Raios gama , Dureza/efeitos dos fármacos , Dureza/fisiologia , Dureza/efeitos da radiação , Técnicas In Vitro , Meniscos Tibiais/efeitos da radiação , Preservação de Órgãos/métodos , Ovinos , Estresse Mecânico , Resistência à Tração/efeitos dos fármacos , Resistência à Tração/fisiologia , Resistência à Tração/efeitos da radiação , Viscosidade
18.
J Mater Sci Mater Med ; 26(2): 69, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25631265

RESUMO

Sterilization through γ-irradiation has been reported to affect collagen mechanical properties, but its possible effects on gelatin based materials have not been investigated up to now. Herein we report the results of a mechanical, chemical and thermal study performed on gelatin films before and after γ-irradiation. The investigation was performed on uncrosslinked films as well as on crosslinked films. To this aim, two common crosslinking agents, glutaraldehyde and genipin, at different concentration (0.15, 0.30 and 0.67%) were used. The results indicate that sterilization significantly affects the mechanical properties of uncrosslinked films, whereas it displays a modest effect on gelatin swelling, release in solution, thermal stability and molecular structure. Both glutaraldehyde and genipin enhance the mechanical properties and stability in solution of the gelatin films. In particular, the values of Young modulus increase as a function of crosslinker concentration up to about 10 and 18 MPa for genipin and glutaraldehyde treated samples respectively. The results of in vitro study demonstrate that the films crosslinked with genipin do not display any cytotoxic reaction, whereas glutaraldehyde crosslinking provokes an acute and dose dependent cytotoxic effect.


Assuntos
Reagentes de Ligações Cruzadas/química , Gelatina/química , Glutaral/química , Iridoides/química , Membranas Artificiais , Esterilização/métodos , Reagentes de Ligações Cruzadas/efeitos da radiação , Módulo de Elasticidade/efeitos da radiação , Raios gama , Gelatina/efeitos da radiação , Glutaral/efeitos da radiação , Iridoides/efeitos da radiação , Teste de Materiais , Doses de Radiação , Estresse Mecânico , Resistência à Tração/efeitos da radiação
19.
Acta Biomater ; 11: 274-82, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25257315

RESUMO

Engineered tissue microenvironments impart specialized cues that drive distinct cellular phenotypes and function. Microenvironments with defined properties, such as mechanical properties and fibril alignment, can elicit specific cellular responses that emulate those observed in vivo. Collagen- and glycosaminoglycan (GAG)-based tissue matrices have been popularized due to their biological ubiquity in a broad range of tissues and the ability to tune structure and mechanical properties through a variety of processes. Here, we investigate the combined effects of static magnetic fields, and GAG and cell encapsulation, on the structure (e.g. collagen fibril orientation) and material properties of collagen matrices. We found that magnetic fields align the collagen-GAG matrix, alter equilibrium mechanical properties and provide a method for encapsulating cells within a three-dimensional aligned matrix. Cells are encapsulated prior to polymerization, allowing for controlled cell density and eliminating the need for cell seeding. Increased relative GAG concentrations reduced the ability to magnetically align collagen fibrils, in part through a mechanism involving increased viscosity and polymerization time of the collagen-GAG solution. This work provides a functional design space for the development of pure collagen and hybrid collagen-GAG matrices in the presence of magnetic fields. Additionally, this work shows that magnetic fields are effective for the fabrication of collagen constructs with controlled fibril orientation, and can be coupled with GAG incorporation to modulate mechanical properties and the response of embedded cells.


Assuntos
Microambiente Celular/fisiologia , Condrócitos/citologia , Colágeno/química , Matriz Extracelular/química , Matriz Extracelular/classificação , Glicosaminoglicanos/química , Engenharia Tecidual/métodos , Animais , Materiais Biomiméticos/síntese química , Bovinos , Proliferação de Células/fisiologia , Sobrevivência Celular/fisiologia , Células Cultivadas , Microambiente Celular/efeitos da radiação , Condrócitos/fisiologia , Colágeno/efeitos da radiação , Força Compressiva/fisiologia , Força Compressiva/efeitos da radiação , Módulo de Elasticidade/fisiologia , Módulo de Elasticidade/efeitos da radiação , Campos Magnéticos , Teste de Materiais , Mecanotransdução Celular/fisiologia , Mecanotransdução Celular/efeitos da radiação , Viscosidade/efeitos da radiação
20.
Ultrasound Med Biol ; 41(1): 35-9, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25438839

RESUMO

We measured acoustic output, expressed as the thermal index (TI) and mechanical index (MI), during fetal echocardiography at the time of the first trimester scan. TI and MI were retrieved from the saved displays during gray-mode, high-definition color flow Doppler and pulsed-wave Doppler (tricuspid flow) ultrasound examinations of the fetal heart and from the ductus venosus assessment. A total of 399 fetal cardiac examinations were evaluated. There was a significant increase in TI values from B-mode studies (0.07 ± 0.04 [mean ± SD]) to color flow mapping (0.2 ± 0.0) and pulsed-wave Doppler studies (0.36 ± 0.05). The TI from ductus venosus assessment (0.1 ± 0.01) was significantly lower than those from Doppler examinations of the heart. MI values from B-mode scans (0.65 ± 0.12) and color flow mapping (0.71 ± 0.11) were comparable, although different, and both values were higher than those from pulsed-wave Doppler tricuspid evaluation (0.39 ± 0.03). There were no differences in MI values from power Doppler assessment between the tricuspid flow and ductus venosus. Safety indices were remarkably stable and were largely constant, especially for color Doppler (TI), tricuspid flow (MI) and ductus venosus assessment (TI, MI). We acquired satisfactory Doppler images and/or signals at acoustic levels that were lower than the actual recommendations and never reached a TI of 0.5.


Assuntos
Temperatura Corporal/fisiologia , Ecocardiografia/métodos , Coração Fetal/diagnóstico por imagem , Coração Fetal/fisiologia , Primeiro Trimestre da Gravidez/fisiologia , Ultrassonografia Pré-Natal/métodos , Absorção de Radiação , Adolescente , Adulto , Temperatura Corporal/efeitos da radiação , Módulo de Elasticidade/fisiologia , Módulo de Elasticidade/efeitos da radiação , Feminino , Coração Fetal/efeitos da radiação , Humanos , Gravidez , Primeiro Trimestre da Gravidez/efeitos da radiação , Doses de Radiação , Radiometria/métodos , Som , Estresse Mecânico , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...