Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.982
Filtrar
1.
J Chromatogr A ; 1726: 464977, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38735117

RESUMO

A magnetic molecularly imprinted polymer (MMIP) adsorbent incorporating amino-functionalized magnetite nanoparticles, nitrogen-doped graphene quantum dots and mesoporous carbon (MIP@MPC@N-GQDs@Fe3O4NH2) was fabricated to extract triazine herbicides from fruit juice. The embedded magnetite nanoparticles simplified the isolation of the adsorbent from the sample solution. The N-GQDs and MPC enhanced adsorption by affinity binding with triazines. The MIP layer provided highly specific recognition sites for the selective adsorption of three target triazines. The extracted triazines were determined by high-performance liquid chromatography (HPLC) coupled with diode-array detection (DAD). The developed method exhibited linearity from 1.5 to 100.0 µg L-1 with a detection limit of 0.5 µg L-1. Recoveries from spiked fruit juice samples were in the range of 80.1- 108.4 %, with a relative standard deviation of less than 6.0 %. The developed MMIP adsorbent demonstrated good selectivity, high extraction efficiency, ease of fabrication and use, and good stability.


Assuntos
Carbono , Sucos de Frutas e Vegetais , Herbicidas , Limite de Detecção , Polímeros Molecularmente Impressos , Pontos Quânticos , Triazinas , Pontos Quânticos/química , Triazinas/química , Triazinas/análise , Triazinas/isolamento & purificação , Herbicidas/análise , Herbicidas/isolamento & purificação , Herbicidas/química , Sucos de Frutas e Vegetais/análise , Adsorção , Polímeros Molecularmente Impressos/química , Carbono/química , Cromatografia Líquida de Alta Pressão/métodos , Nanopartículas de Magnetita/química , Microextração em Fase Sólida/métodos , Impressão Molecular/métodos , Porosidade , Grafite/química
2.
Anal Chim Acta ; 1306: 342609, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38692788

RESUMO

BACKGROUND: Accurate quantitative analysis of small molecule metabolites in biological samples is of great significance. Hydroxypolycyclic aromatic hydrocarbons (OH-PAHs) are metabolic derivatives of emerging pollutants, reflecting exposure to polycyclic aromatic hydrocarbons (PAHs). Macromolecules such as proteins and enzymes in biological samples will interfere with the accurate quantification of OH-PAHs, making direct analysis impossible, requiring a series of complex treatments such as enzymatic hydrolysis. Therefore, the development of matrix-compatible fiber coatings that can exclude macromolecules is of great significance to improve the ability of solid-phase microextraction (SPME) technology to selectively quantify small molecules in complex matrices and achieve rapid and direct analysis. RESULTS: We have developed an innovative coating with a stable macromolecular barrier using electrospinning and flexible filament winding (FW) technologies. This coating, referred to as the hollow fibrous covalent organic framework@polyionic liquid (F-COF@polyILs), demonstrates outstanding conductivity and stability. It accelerates the adsorption equilibrium time (25 min) for polar OH-PAHs through electrically enhanced solid-phase microextraction (EE-SPME) technology. Compared to the powder form, F-COF@polyILs coating displays effective non-selective large-size molecular sieving. Combining gas chromatography-tandem triple quadrupole mass spectrometry (GC-MS/MS), we have established a simple, efficient quantitative analysis method for OH-PAHs with a low detection limit (0.008-0.05 ng L-1), wide linear range (0.02-1000 ng L-1), and good repeatability (1.0%-7.3 %). Experimental results show that the coated fiber exhibits good resistance to matrix interference (2.5%-16.7 %) in complex biological matrices, and has been successfully used for OH-PAHs analysis in human urine and plasma. SIGNIFICANCE: FW technology realizes the transformation of the traditional powder form of COF in SPME coating to a uniform non-powder coating, giving its ability to exclude large molecules in complex biological matrices. A method for quantitatively detecting OH-PAHs in real biological samples was also developed. Therefore, the filament winding preparation method for F-COF@polyILs coated fibers, along with fibrous COFs' morphology control, has substantial implications for efficiently extracting target compounds from complex matrices.


Assuntos
Microextração em Fase Sólida , Microextração em Fase Sólida/métodos , Estruturas Metalorgânicas/química , Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Substâncias Macromoleculares/química , Limite de Detecção , Adsorção , Técnicas Eletroquímicas/métodos
3.
Anal Chim Acta ; 1309: 342676, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38772658

RESUMO

BACKGROUND: Methylparaben (MP), a commonly used antibacterial preservative, is widely used in personal care products, foods, and pharmaceuticals. MP and its metabolites are easy to enter the water environment, and their exposure and accumulation have negative effects on the ecological environment and human health, and have endocrine disrupting activity and potential physiological toxicity. It is still the primary issue of environmental analysis and ecological risk assessment to develop simple and reliable methods for simultaneous sensitive detection of these compounds in environmental water. RESULTS: In this paper, a flexible molecularly imprinted fiber array strategy is proposed for simultaneous enrichment and detection of trace MP and its four main metabolites. The experimental results showed that the three-fiber imprinted fiber array constructed by MP imprinted fiber had the best effect on the simultaneous enrichment of these five target analytes. The enrichment capacity of the imprinted fiber array was 214-456 times, 314-1201 times and 38-685 times that of commercial PA, PDMS and PDMS/DVB fiber arrays, respectively. The limit of detection (LOD) of this method was 0.033 µg L-1. The spiked recovery rate was 86.78-113.96 %, and RSD was less than 9.17 %. In addition, this molecularly imprinted SPME fiber array has good stability, long service life and can be used repeatedly at least 100 times. SIGNIFICANCE: This molecularly imprinted fiber array strategy can flexibly assemble different molecularly imprinted SPME fibers together, effectively improve the enrichment ability and detection sensitivity, and achieve simultaneous selective enrichment and detection of several analytes. This is an easy, efficient and reliable method for monitoring several trace analytes simultaneously in intricate environmental matrices.


Assuntos
Limite de Detecção , Impressão Molecular , Parabenos , Microextração em Fase Sólida , Parabenos/análise , Microextração em Fase Sólida/métodos , Poluentes Químicos da Água/análise
4.
Metabolomics ; 20(3): 59, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38773019

RESUMO

INTRODUCTION: Thyroid cancer incidence rate has increased substantially worldwide in recent years. Fine needle aspiration biopsy (FNAB) is currently the golden standard of thyroid cancer diagnosis, which however, is invasive and costly. In contrast, breath analysis is a non-invasive, safe and simple sampling method combined with a promising metabolomics approach, which is suitable for early cancer diagnosis in high volume population. OBJECTIVES: This study aims to achieve a more comprehensive and definitive exhaled breath metabolism profile in papillary thyroid cancer patients (PTCs). METHODS: We studied both end-tidal and mixed expiratory breath, solid-phase microextraction gas chromatography coupled with high resolution mass spectrometry (SPME-GC-HRMS) was used to analyze the breath samples. Multivariate combined univariate analysis was applied to identify potential breath biomarkers. RESULTS: The biomarkers identified in end-tidal and mixed expiratory breath mainly included alkanes, olefins, enols, enones, esters, aromatic compounds, and fluorine and chlorine containing organic compounds. The area under the curve (AUC) values of combined biomarkers were 0.974 (sensitivity: 96.1%, specificity: 90.2%) and 0.909 (sensitivity: 98.0%, specificity: 74.5%), respectively, for the end-tidal and mixed expiratory breath, indicating of reliability of the sampling and analysis method CONCLUSION: This work not only successfully established a standard metabolomic approach for early diagnosis of PTC, but also revealed the necessity of using both the two breath types for comprehensive analysis of the biomarkers.


Assuntos
Biomarcadores Tumorais , Testes Respiratórios , Cromatografia Gasosa-Espectrometria de Massas , Metabolômica , Microextração em Fase Sólida , Câncer Papilífero da Tireoide , Neoplasias da Glândula Tireoide , Humanos , Metabolômica/métodos , Câncer Papilífero da Tireoide/diagnóstico , Câncer Papilífero da Tireoide/metabolismo , Testes Respiratórios/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Microextração em Fase Sólida/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Biomarcadores Tumorais/análise , Biomarcadores Tumorais/metabolismo , Adulto , Neoplasias da Glândula Tireoide/diagnóstico , Neoplasias da Glândula Tireoide/metabolismo , Detecção Precoce de Câncer/métodos , Idoso
5.
Mikrochim Acta ; 191(6): 360, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38819644

RESUMO

A novel in-tube solid-phase microextraction coupled with an ultra-high performance liquid chromatography-mass spectrometry method has been established for simultaneous quantification of three crucial brain biomarkers N-acetylaspartic acid (NAA), N-acetylglutamic acid (NAG), and N-acetylaspartylglutamic acid (NAAG). A polymer monolith with quaternary ammonium as the functional group was designed and exhibited efficient enrichment of target analytes through strong anion exchange interaction. Under the optimized conditions, the proposed method displayed wide linear ranges (0.1-80 nM for NAA and NAG, 0.2-160 nM for NAAG) with good precision (RSDs were lower than 15%) and low limits of detection (0.019-0.052 nM), which is by far the most sensitive approach for NAA, NAG, and NAAG determination. Furthermore, this approach has been applied to measure the target analytes in mouse brain samples, and endogenous NAA, NAG, and NAAG were successfully detected and quantified from only around 5 mg of cerebral cortex, cerebellum, and hippocampus. Compared with existing methods, the newly developed method in the current study provides highest sensitivity and lowest sample consumption for NAA, NAG, and NAAG measurements, which would potentially be utilized in determining and tracking these meaningful brain biomarkers in diseases or treatment processes, benefiting the investigations of pathophysiology and treatment of brain disorders.


Assuntos
Ácido Aspártico , Encéfalo , Dipeptídeos , Microextração em Fase Sólida , Espectrometria de Massas em Tandem , Animais , Ácido Aspártico/análogos & derivados , Ácido Aspártico/análise , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Camundongos , Microextração em Fase Sólida/métodos , Encéfalo/metabolismo , Dipeptídeos/análise , Limite de Detecção , Biomarcadores/análise , Masculino , Química Encefálica , Glutamatos
6.
J Chromatogr A ; 1727: 464978, 2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-38788401

RESUMO

A novel azo-linked porous organic polymer (AL-POP) was synthesized from caffeic acid and benzidine via an azo-coupling reaction and characterized by FTIR, SEM-EDS, BET, TGA, XRD and zeta potential analysis. AL-POPs were incorporated into melamine sponges and used for pipette tip micro solid-phase extraction (PT-MSPE) of six types of B vitamins (including thiamine, riboflavin, nicotinamide, pyridoxine, folic acid, and cyanocobalamin). After extraction, the samples were analyzed using high performance liquid chromatography-diode array detection (HPLC-DAD) system. The effect of AL-POP composition on the extraction efficiency (EE) of vitamins was investigated and benzidine to caffeic acid mol ratio of 1.5, 3.35 mmol of NaNO2, and reaction time of 8 h were selected as optimum conditions. The efficiency of the extraction process was improved by optimizing various parameters such as the amount of sorbent, pH and ionic strength of the sample, sample volume, number of sorption and desorption cycles, type of wash solvent, and type and volume of eluent solvent. Linearity (R2≥0.9987), Limit of detection (LOD) (11.88-18.97 ng/mL), limit of quantification (LOQ) (39.62-63.23 ng/mL), and enrichment factor (EF) (1.27-4.31) were obtained using calibration curves plotted under optimum conditions. Recovery values of these six B vitamins in the spiked multivitamin syrup samples varied from 80.01% to 108.35%, with a relative standard deviation (RSD) below 5.44%. Eventually, the optimized method was successfully used to extract and quantify the B vitamins in multivitamin syrup and non-alcoholic beer.


Assuntos
Limite de Detecção , Triazinas , Complexo Vitamínico B , Triazinas/análise , Triazinas/química , Triazinas/isolamento & purificação , Porosidade , Cromatografia Líquida de Alta Pressão/métodos , Complexo Vitamínico B/análise , Complexo Vitamínico B/química , Complexo Vitamínico B/isolamento & purificação , Adsorção , Polímeros/química , Compostos Azo/análise , Compostos Azo/química , Compostos Azo/isolamento & purificação , Microextração em Fase Sólida/métodos , Extração em Fase Sólida/métodos , Concentração de Íons de Hidrogênio
7.
J Chromatogr A ; 1727: 464989, 2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-38763085

RESUMO

Ultrahigh-performance liquid chromatography coupled with high-field quadrupole Orbitrap high resolution mass spectrometry was used for the separation and determination of 20 antihistamines, and a dispersive micro solid-phase extraction procedure using high-performance absorbing material was developed as a sample preparation strategy for extracting 20 antihistamines from milk. Instrument conditions and key parameters influencing extraction efficiency were investigated to obtain an optimized method. The limit of detection for 20 antihistamines in milk using this method is 0.05 µg/L to 1.0 µg/L. Recoveries are between 80.7 % and 108.3 %, and the relative standard deviation is less than 15 %. It is suitable for confirmatory monitoring and quantitative analysis of 20 antihistamines in milk. The results show that antihistamines in milk may be noteworthy issues for human health and environmental pollution.


Assuntos
Antagonistas dos Receptores Histamínicos , Limite de Detecção , Leite , Cromatografia Líquida de Alta Pressão/métodos , Leite/química , Animais , Antagonistas dos Receptores Histamínicos/análise , Antagonistas dos Receptores Histamínicos/isolamento & purificação , Microextração em Fase Sólida/métodos , Espectrometria de Massas/métodos , Bovinos , Reprodutibilidade dos Testes
8.
J Chromatogr A ; 1727: 465000, 2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-38763086

RESUMO

Design and preparation of fiber coatings with excellent electrochemical performance and high polarity is significant for efficient extraction of polar targets in electro-enhanced solid-phase microextraction (EE-SPME). In this work, a combination strategy for structure regulation of covalent organic framework (COF) was proposed to fabricate a nitrogen-rich thiocarbamide linked COF coating (Thiocarbamide-TZ-DHTP) via molecular design and post-synthetic thiocarbamide conversion. The prepared COF coating possesses a large number of O, N, and S functional groups, which not only endow the coating with higher polarity but also significantly enhance its electrochemical performance. The COF coating was used for EE-SPME of polar bisphenols (BPs), demonstrating excellent enrichment efficiency and durability. Subsequently, coupled with gas chromatography-tandem mass spectrometry (GC-MS/MS), a sensitive method was developed for determination of trace BPs. The established method possess wide linear ranges (2.0-800.0 ng L-1), good correlation coefficients (0.9985-0.9994) and low detection limits (0.1-2.0 ng L-1). Moreover, the established method had been successfully applied to detection of trace BPs in tea beverage with satisfactory recoveries (81.6 % to 118.6 %). This research provides a feasible pathway for preparing COF coating with excellent electrochemical performance and high polarity for EE-SPME.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas , Limite de Detecção , Estruturas Metalorgânicas , Nitrogênio , Fenóis , Microextração em Fase Sólida , Espectrometria de Massas em Tandem , Microextração em Fase Sólida/métodos , Fenóis/análise , Fenóis/isolamento & purificação , Fenóis/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Estruturas Metalorgânicas/química , Espectrometria de Massas em Tandem/métodos , Nitrogênio/química , Compostos Benzidrílicos/análise , Compostos Benzidrílicos/isolamento & purificação , Compostos Benzidrílicos/química , Técnicas Eletroquímicas/métodos , Reprodutibilidade dos Testes , Chá/química
9.
Anal Chim Acta ; 1308: 342658, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38740458

RESUMO

BACKGROUND: The environmental impact of sample preparation should be minimized through simplification of the procedures and the use of natural, renewable and/or reusable materials. In such scenario, thin-film microextraction fulfils the former criteria, as it enables few steps and miniaturization, thus small amount of extraction phase. At the same time, the use of sorbents such as biochars obtained from biomass waste is even more promoted due to their availability at low cost and increased life-cycle in a circular economy vision. However, it is not always easy to combine these criteria in sample preparation. RESULTS: A thin film microextraction was developed for the determination of steroids in aqueous samples, entailing a membrane made of cellulose triacetate and a wood-derived biochar (Nuchar®) as carbon precursor. Different characterization techniques showed the successful preparation, whereas the sorption kinetics experiments demonstrated that biochar is responsible for the extraction with the polymer acting as a smart support. After a study about membranes' composition in terms of biochar amounts (4 %, 10 %, 16 % wt) and type of synthesis set up, the ceramic 3D-mold was selected, achieving reproducible and ready-to-use membranes with composition fixed as 10 %. Different elution conditions, viz. type and time of agitation, type, composition and volume of eluent, were evaluated. The final microextraction followed by HPLC-MS/MS quantification was successfully validated in river and wastewater treatment plant effluent samples in terms of accuracy (R% 64-123 %, RSD<19 % in river; R% 61-118 %, RSD <18 % in effluent, n = 4), sensitivity (MQLs 0.2-8.5 ng L-1) and robustness. SIGNIFICANCE: This novel biochar-based polymeric film proved to be a valid and sustainable sorbent, in terms of extraction capability, ease of preparation and greenness. By comparison with literature and the greenness evaluation with the most recent metric tools, this method expands the potential applicability of the thin-film microextraction and opens up innovative scenarios for sustainable procedures entailing the use of biochars entrapped in bio-polymers.


Assuntos
Carvão Vegetal , Polímeros , Águas Residuárias , Poluentes Químicos da Água , Carvão Vegetal/química , Águas Residuárias/análise , Águas Residuárias/química , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/isolamento & purificação , Polímeros/química , Adsorção , Esteroides/análise , Esteroides/química , Esteroides/isolamento & purificação , Microextração em Fase Sólida/métodos
10.
Anal Chim Acta ; 1306: 342621, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38692790

RESUMO

BACKGROUND: In vivo solid-phase microextraction (SPME) is a minimally invasive, non-exhaustive sample-preparation technique that facilitates the direct isolation of low molecular weight compounds from biological matrices in living systems. This technique is especially useful for the analysis of phytocannabinoids (PCs) in plant material, both for forensic purposes and for monitoring the PC content in growing Cannabis spp. plants. In contrast to traditional extraction techniques, in vivo SPME enables continuous tracking of the changes in the level of PCs during plant growth without the need for plant material collection. In this study, in vivo SPME utilizing biocompatible C18 probes and liquid-chromatography coupled to quadrupole time-of flight mass spectrometry (LC-Q-TOF-MS) is proposed as a novel strategy for the extraction and analysis of the acidic forms of five PCs in growing medicinal cannabis plants. RESULTS: The SPME method was optimized by testing various parameters, including the extraction phase (coating), extraction and desorption times, and the extraction temperature. The proposed method was validated with satisfactory analytical performance regarding linearity (10-3000 ng/mL), limits of quantification, and precision (relative standard deviations below 5.5 %). The proposed method was then successfully applied for the isolation of five acidic forms of PCs, which are main components of growing medicinal cannabis plants. As a proof-of-concept, SPME probes were statically inserted into the inflorescences of two varieties of Cannabis spp. plants (i.e., CBD-dominant and Δ9-THC-dominant) cultivated under controlled conditions for 30 min extraction of tetrahydrocannabinolic acid (Δ9-THCA), cannabidiolic acid (CBDA), cannabigerolic acid (CBGA), cannabiviarinic acid (CBVA), and tetrahydrocannabivarinic acid (THCVA). SIGNIFICANCE AND NOVELTY: The results confirmed that the developed SPME-LC-Q-TOF-MS method is a precise and efficient tool that enables direct and rapid isolation and analysis of PCs under in vivo conditions. The proposed methodology is highly appealing option for monitoring the metabolic pathways and compositions of multiple PCs in medicinal cannabis at different stages of plant growth.


Assuntos
Canabinoides , Cannabis , Espectrometria de Massa com Cromatografia Líquida , Microextração em Fase Sólida , Canabinoides/análise , Cannabis/química , Espectrometria de Massa com Cromatografia Líquida/métodos , Microextração em Fase Sólida/métodos
11.
J Chromatogr A ; 1725: 464931, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38703457

RESUMO

Atractylodis rhizoma is a common bulk medicinal material with multiple species. Although different varieties of atractylodis rhizoma exhibit variations in their chemical constituents and pharmacological activities, they have not been adequately distinguished due to their similar morphological features. Hence, the purpose of this research is to analyze and characterize the volatile organic compounds (VOCs) in samples of atractylodis rhizoma using multiple techniques and to identify the key differential VOCs among different varieties of atractylodis rhizoma for effective discrimination. The identification of VOCs was carried out using headspace solid-phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS) and headspace gas chromatography-ion mobility spectrometry (HS-GC-IMS), resulting in the identification of 60 and 53 VOCs, respectively. The orthogonal partial least squares discriminant analysis (OPLS-DA) model was employed to screen potential biomarkers and based on the variable importance in projection (VIP ≥ 1.2), 24 VOCs were identified as critical differential compounds. Random forest (RF), K-nearest neighbor (KNN) and back propagation neural network based on genetic algorithm (GA-BPNN) models based on potential volatile markers realized the greater than 90 % discriminant accuracies, which indicates that the obtained key differential VOCs are reliable. At the same time, the aroma characteristics of atractylodis rhizoma were also analyzed by ultra-fast gas chromatography electronic nose (Ultra-fast GC E-nose). This study indicated that the integration of HS-SPME-GC-MS, HS-GC-IMS and ultra-fast GC E-nose with chemometrics can comprehensively reflect the differences of VOCs in atractylodis rhizoma samples from different varieties, which will be a prospective tool for variety discrimination of atractylodis rhizoma.


Assuntos
Atractylodes , Nariz Eletrônico , Cromatografia Gasosa-Espectrometria de Massas , Microextração em Fase Sólida , Compostos Orgânicos Voláteis , Compostos Orgânicos Voláteis/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Microextração em Fase Sólida/métodos , Atractylodes/química , Espectrometria de Mobilidade Iônica/métodos , Rizoma/química , Análise Discriminante
12.
Food Res Int ; 187: 114359, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38763643

RESUMO

Chinese Xiaokeng green tea (XKGT) possesses elegant and fascinating aroma characteristics, but its key odorants are still unknown. In this study, 124 volatile compounds in the XKGT infusion were identified by headspace-solid phase microextraction (HS-SPME), stir bar sorptive extraction (SBSE), and solvent extraction-solid phase extraction (SE-SPE) combined with gas chromatography-mass spectrometry (GC-MS). Comparing these three pretreatments, we found HS-SPME was more efficient for headspace compounds while SE-SPE was more efficient for volatiles with higher boiling points. Furthermore, SBSE showed more sensitive to capture ketones then was effective to the application of pretreatment of aroma analysis in green tea. The aroma intensities (AIs) were further identified by gas chromatography-olfactometry (GC-O). According to the AI and relative odor activity value (rOAV), 27 compounds were identified as aroma-active compounds. Quantitative descriptive analysis (QDA) showed that the characteristic aroma attributes of XKGT were chestnut-like, corn-like, fresh, and so on. The results of network analysis showed that (E, Z)-2,6-nonadienal, nonanal, octanal and nerolidol were responsible for the fresh aroma. Similarly, dimethyl sulfide, (E, E)-2,4-heptadienal, (E)-2-octenal and ß-cyclocitral contributed to the corn-like aroma. Furthermore, indole was responsible for the chestnut-like and soybean-like aroma. This study contributes to a better understanding of the molecular mechanism of the aroma characteristics of XKGT.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas , Odorantes , Olfatometria , Microextração em Fase Sólida , Chá , Compostos Orgânicos Voláteis , Odorantes/análise , Chá/química , Compostos Orgânicos Voláteis/análise , Microextração em Fase Sólida/métodos , Humanos , Camellia sinensis/química , Extração em Fase Sólida/métodos
13.
Food Res Int ; 187: 114398, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38763656

RESUMO

Nowadays, it is important to monitor the freshness of meat during storage to protect consumers' health. Volatile organic compounds (VOCs) are responsible for odour and taste of food, and they give an indication about meat quality and freshness. This study had the aim to seek and select potential new markers of meat spoilage through a semi-quantitative analysis in five types of meat (beef, raw and baked ham, pork sausage and chicken) and then to develop a new quantitative analytical method to detect and quantify potential markers on five types of meat simultaneously. Firstly, a new headspace-solid phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS) method was developed to evaluate the volatile profile of five types of meat, preserved at 4 °C for 5 days. Among the 40 compounds identified, 15 were chosen and selected as potential shelf-life markers on the basis of their presence in most of meat samples or/and for their constant increasing/decreasing trend within the sample. Afterwards, a quantitative HS-SPME-GC-MS analytical method was developed to confirm which VOCs can be considered markers of shelf-life for these meat products, stored at 4 °C for 12 days. Some of the compounds analyzed attracted attention as they can be considered markers of shelf-life for at least 4 types of meat: 1-butanol, 3-methylbutanol, 1-hexanol, 2-nonanone, nonanal, 1-octen-3-ol and linalool. In conclusion, in this study a new quantitative HS-SPME-GC-MS analytical method to quantity 15 VOCs in five types of meat was developed and it was demonstrated that some of the compounds quantified can be considered markers of shelf-life for some of the meat products analyzed.


Assuntos
Armazenamento de Alimentos , Cromatografia Gasosa-Espectrometria de Massas , Produtos da Carne , Microextração em Fase Sólida , Compostos Orgânicos Voláteis , Compostos Orgânicos Voláteis/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Microextração em Fase Sólida/métodos , Produtos da Carne/análise , Animais , Suínos , Odorantes/análise , Bovinos , Aldeídos/análise , Galinhas , Cetonas/análise , Pentanóis/análise , Monoterpenos Acíclicos/análise , Octanóis
14.
J Agric Food Chem ; 72(19): 11124-11139, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38698543

RESUMO

Terpenes and pentene dimers are less studied volatile organic compounds (VOCs) but are associated with specific features of extra virgin olive oils (EVOOs). This study aimed to analyze mono- and sesquiterpenes and pentene dimers of Italian monovarietal EVOOs over 3 years (14 cultivars, 225 samples). A head space-solid-phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS) method recently validated was used for terpene and pentene dimer quantitation. The quantitative data collected were used for both the characterization and clustering of the cultivars. Sesquiterpenes were the molecules that most characterized the different cultivars, ranging from 3.908 to 38.215 mg/kg; different groups of cultivars were characterized by different groups of sesquiterpenes. Pentene dimers (1.336 and 3.860 mg/kg) and monoterpenes (0.430 and 1.794 mg/kg) showed much lower contents and variability among cultivars. The application of Kruskal-Wallis test-PCA-LDA-HCA to the experimental data allowed defining 4 clusters of cultivars and building a predictive model to classify the samples (94.3% correct classification). The model was further tested on 33 EVOOs, correctly classifying 91% of them.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas , Olea , Azeite de Oliva , Controle de Qualidade , Microextração em Fase Sólida , Terpenos , Compostos Orgânicos Voláteis , Microextração em Fase Sólida/métodos , Azeite de Oliva/química , Itália , Terpenos/química , Terpenos/análise , Olea/química , Compostos Orgânicos Voláteis/química , Quimiometria/métodos , Dimerização
15.
Anal Methods ; 16(20): 3164-3178, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38717233

RESUMO

Traditional sample preparation techniques based on liquid-liquid extraction (LLE) or solid-phase extraction (SPE) often suffer from a major error due to the matrix effects caused by significant co-extraction of matrix components. The implementation of a modern extraction technique such as solid-phase microextraction (SPME) was aimed at reducing analysis time and the use of organic solvents, as well as eliminating pre-analytical and analytical errors. Solid-phase microextraction (SPME) is an innovative technique for extracting low molecular weight compounds (less than 1500 Da) from highly complex matrices, including biological matrices. It has a wide range of applications in various types of analysis including pharmaceutical, clinical, metabolomics and proteomics. SPME has a number of advantages over other extraction techniques. Among the most important are low environmental impact, the ability to sample and preconcentrate analytes in one step, simple automation, and the ability to extract multiple analytes simultaneously. It is expected to become, in the future, another method for cell cycle research. Numerous available literature sources prove that solid-phase microextraction can be a future technique in many scientific fields, including pharmaceutical sciences. This paper provides a literature review of trends in SPME coatings and pharmacological applications.


Assuntos
Microextração em Fase Sólida , Microextração em Fase Sólida/métodos , Humanos , Preparações Farmacêuticas/análise
16.
J Chromatogr A ; 1726: 464961, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38723491

RESUMO

The improvement of the stability and adsorption properties of materials on targets in sample pre-treatment has long been an objective. Extensive efforts have been made to achieve this goal. In this work, metal-organic framework Ni-MOF precursors were first synthesized by solvothermal method using polyvinylpyrrolidone (PVP) as an ideal templating agent, stabiliser and nanoparticle dispersant. After carbonization and acid washing, the nanoporous carbon microspheres material (Ni@C-acid) was obtained. Compared with the material without acid treatment (Ni@C), the specific surface area, pore volume, adsorption performance of Ni@C-acid were increased. Thanks to its excellent characteristics (high stability, abundant benzene rings), Ni@C-acid was used as fiber coatings in headspace solid-phase microextraction (HS-SPME) technology for extraction and preconcentration of polycyclic aromatic hydrocarbons (PAHs) prior to gas chromatography-flame ionization detector (GC-FID) analysis. The experimental parameters of extraction temperature, extraction time, agitation speed, desorption temperature, desorption time and sodium chloride (NaCl) concentration were studied. Under optimal experimental conditions, the wide linear range (0.01-30 ng mL-1), the good correlation coefficient (0.9916-0.9984), the low detection limit (0.003-0.011 ng mL-1), and the high enrichment factor (5273-13793) were obtained. The established method was successfully used for the detection of trace PAHs in actual tea infusions samples and satisfied recoveries ranging from 80.94-118.62 % were achieved. The present work provides a simple method for the preparation of highly stable and adsorbable porous carbon microsphere materials with potential applications in the extraction of environmental pollutants.


Assuntos
Carbono , Limite de Detecção , Estruturas Metalorgânicas , Microesferas , Hidrocarbonetos Policíclicos Aromáticos , Microextração em Fase Sólida , Chá , Microextração em Fase Sólida/métodos , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Hidrocarbonetos Policíclicos Aromáticos/análise , Chá/química , Carbono/química , Estruturas Metalorgânicas/química , Porosidade , Adsorção , Níquel/química , Níquel/isolamento & purificação , Cromatografia Gasosa/métodos , Reprodutibilidade dos Testes
17.
Molecules ; 29(10)2024 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-38792139

RESUMO

In the past few decades, considerable scientific strides have been made in the subject of drug analysis in human biological samples. However, the risk caused by incorrect drug plasma levels in patients still remains an important concern. This review paper attempts to investigate the advances made over the last ten years in common sample preparation techniques (SPT) for biological samples based on solid sorbents, including solid-phase extraction (SPE) and solid-phase micro-extraction (SPME), and in particular in the field of molecularly imprinted polymers (MIPs), including non-stimuli-responsive and stimuli-responsive adsorbents. This class of materials is known as 'smart adsorbents', exhibiting tailored responses to various stimuli such as magnetic fields, pH, temperature, and light. Details are provided on how these advanced SPT are changing the landscape of modern drug analysis in their coupling with liquid chromatography-mass spectrometry (LC-MS) analytical techniques, a general term that includes high-performance liquid chromatography (HPLC) and ultra-high performance liquid chromatography (UHPLC), as well as any variation of MS, such as tandem (MS/MS), multiple-stage (MSn), and high-resolution (HRMS) mass spectrometry. Some notes are also provided on coupling with less-performing techniques, such as high-performance liquid chromatography with ultraviolet (HPLC-UV) and diode array detection (HPLC-DAD) detection. Finally, we provide a general review of the difficulties and benefits of the proposed approaches and the future prospects of this research area.


Assuntos
Extração em Fase Sólida , Humanos , Extração em Fase Sólida/métodos , Preparações Farmacêuticas/análise , Preparações Farmacêuticas/química , Microextração em Fase Sólida/métodos , Cromatografia Líquida de Alta Pressão/métodos , Polímeros Molecularmente Impressos/química , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos
18.
J Hazard Mater ; 472: 134609, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38759280

RESUMO

Simultaneous rapid screening of multiple drugs of abuse in environmental water facilitates effective monitoring and trend assessments. Herein, a novel porphyrin-based metal organic frameworks modified Ti3C2Tx nanosheets (Cu-TCPP/Ti3C2Tx) composite was prepared and utilized as solid-phase microextraction (SPME) coating for the simultaneous analysis of 21 drugs from water samples. The composite was embedded with matrix-compatible polyacrylonitrile binder to prepare a coated blade with thin and uniform coating layer. Ambient mass spectrometry (MS) technique was used to create a coated blade spray-MS (CBS-MS) method for the quantitative determination of drugs in water samples. High throughput and automated sample preparation were achieved with the use of a Concept 96-well plate system, enabling analysis of 21 drugs of abuse within 1 min per sample, while using only 8 µL of organic solvent for desorption and CBS-MS detection. The developed method showed favorable linearity (R2 ≥ 0.9983) in the range of 0.05 to 10 ng mL-1, low limits of detection (1.5-9.0 ng L-1), sufficient recovery (67.6-133.2%), as well as satisfactory precision (RSDs≤13.5%). This study not only delivers a novel and efficient SPME coating composite, but also demonstrates the excellent performance of a high-throughput, efficient, and green analytical method for determination of drugs in environmental water.


Assuntos
Espectrometria de Massas , Estruturas Metalorgânicas , Microextração em Fase Sólida , Poluentes Químicos da Água , Poluentes Químicos da Água/análise , Microextração em Fase Sólida/métodos , Estruturas Metalorgânicas/química , Espectrometria de Massas/métodos , Titânio/química , Limite de Detecção , Drogas Ilícitas/análise , Monitoramento Ambiental/métodos , Preparações Farmacêuticas/análise , Preparações Farmacêuticas/química
19.
Anal Chim Acta ; 1304: 342555, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38637039

RESUMO

BACKGROUND: Omics is used as an analytical tool to investigate wine authenticity issues. Aging authentication ensures that the wine has undergone the necessary maturation and developed its desired organoleptic characteristics. Considering that aged wines constitute valuable commodities, the development of advanced omics techniques that guarantee aging authenticity and prevent fraud is essential. RESULTS: Α solid phase microextraction Arrow method combined with comprehensive two-dimensional gas chromatography-mass spectrometry was developed to identify volatiles in red wines and investigate how aging affects their volatile fingerprint. The method was optimized by examining the critical parameters that affect the solid phase microextraction Arrow extraction (stirring rate, extraction time) process. Under optimized conditions, extraction took place within 45 min under stirring at 1000 rpm. In all, 24 monovarietal red wine samples belonging to the Xinomavro variety from Naoussa (Imathia regional unit of Macedonia, Greece) produced during four different vintage years (1998, 2005, 2008 and 2015) were analyzed. Overall, 237 volatile compounds were tentatively identified and were treated with chemometric tools. Four major groups, one for each vintage year were revealed using the Hierarchical Clustering Analysis. The first two Principal Components of Principal Component Analysis explained 86.1% of the total variance, showing appropriate grouping of the wine samples produced in the same crop year. A two-way orthogonal partial least square - discriminant analysis model was developed and successfully classified all the samples to the proper class according to the vintage age, establishing 17 volatile markers as the most important features responsible for the classification, with an explained total variance of 88.5%. The developed prediction model was validated and the analyzed samples were classified with 100% accuracy according to the vintage age, based on their volatile fingerprint. SIGNIFICANCE: The developed methodology in combination with chemometric techniques allows to trace back and confirm the vintage year, and is proposed as a novel authenticity tool which opens completely new and hitherto unexplored possibilities for wine authenticity testing and confirmation.


Assuntos
Compostos Orgânicos Voláteis , Vinho , Vinho/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Microextração em Fase Sólida/métodos , Quimiometria , Análise por Conglomerados , Compostos Orgânicos Voláteis/análise
20.
J Chromatogr A ; 1725: 464875, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38678692

RESUMO

Ultrasonic-assisted dispersive micro solid phase extraction (UA-DMSPE) is proposed as a fast and easy technique for the extraction and preconcentration of methadone and tramadol from serum samples. Different sorbents including carbon nanotubes, oxidized carbon nanotubes, and TiO2 nanoparticles were compared to extract methadone and tramadol. The best performance was obtained using oxidized carbon nanotubes due to the strong affinity between the drugs and carbon nanotube adsorbents. Final analysis of drugs performed by using gas chromatography-mass spectrometric detection. Different parameters affecting the extraction efficiency, such as the sample volume, amount of adsorbent, desorption solvent type and volume, centrifugation time, and speed were investigated and optimized. The striking features of this technique are correlated to its speed and the small volumes of sample (about 1 mL), desorption solvent (about 50 µL), and adsorbent (about 0.001 g) for analysis of drugs, and finally, milder centrifugation conditions relative to the previously reported adsorbent. The optimal parameters were achieved as follows: pH value was set at 9, the sample volume was adjusted to 1200 µL, the amount of adsorbent used was 1 mg, the extraction time was set at 5 min, and the volume of the desorption solvent was adjusted to 50 µL. The limits of detections (0.5 and 0.8 ng mL-1) and quantifications (1.5 and 2.5 ng mL-1) were obtained for methadone and tramadol, respectively. The developed method also showed good repeatability, relative standard deviation (RSD) of 9.49 % and 7.47 % (n = 5), for the spiked aqueous solution at the concentration level of 10, 50, and 100 ng mL-1 for analytes, and linearity, R ≥ 0.9809. The results showed that UA-DMSPE is a quick, relatively inexpensive, and environmentally friendly alternative technique for the extraction of opiate drugs from serum samples.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas , Limite de Detecção , Metadona , Microextração em Fase Sólida , Tramadol , Tramadol/sangue , Metadona/sangue , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Microextração em Fase Sólida/métodos , Nanotubos de Carbono/química , Reprodutibilidade dos Testes , Adsorção , Titânio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...