1.
Reprod Health ; 18(1): 115, 2021 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-34108001

RESUMO

BACKGROUND: Delivery is a critical moment for pregnant women and babies, and careful monitoring is essential throughout the delivery process. The partograph is a useful tool for monitoring and assessing labour progress as well as maternal and foetal conditions; however, it is often used inaccurately or inappropriately. A gap between practices and evidence-based guidelines has been reported in Cambodia, perhaps due to a lack of evidence-based knowledge in maternity care. This study aims to address to what extent skilled birth attendants in the first-line health services in Cambodia have knowledge on the management of normal delivery, and what factors are associated with their level of knowledge. METHODS: Midwives and nurses were recruited working in maternity in first-line public health facilities in Phnom Penh municipality, Kampong Cham and Svay Rieng provinces. Two self-administered questionnaires were applied. The first consisted of three sections with questions on monitoring aspects of the partograph: progress of labour, foetal, and maternal conditions. The second consisted of questions on diagnostic criteria, normal ranges, and standard intervals of monitoring during labour. A multiple linear regression analysis was performed to identify relationships between characteristics of the participants and the questionnaire scores. RESULTS: Of 542 eligible midwives and nurses, 523 (96%) participated. The overall mean score was 58%. Only 3% got scores of more than 90%. Multivariate analysis revealed that 'Kampong Cham province', 'younger age', and 'higher qualification' were significantly associated with higher scores. Previous training experience was not associated with the score. Substantial proportions of misclassification of monitoring items during labour were found; for example, 61% answered uterine contraction as a foetal condition, and 44% answered foetal head descent and 26% answered foetal heart rate as a maternal condition. CONCLUSION: This study found that knowledge was low on delivery management among skilled birth attendants. Previous training experience did not influence the knowledge level. A lack of understanding of physiology and anatomy was implied. Further experimental approaches should be attempted to improve the knowledge and quality of maternity services in Cambodia.


Pregnancy and childbirth are natural phenomena, but sometimes have risk for mothers and babies. Therefore, childbirth should be carefully and continuously monitored by the health care professional. The 'partograph' is a useful tool that defines three monitoring aspects of the delivery progress, and conditions of the mother and intrauterine baby. However, it is often used inaccurately or inappropriately in low- and middle-income countries. We hypothesised that health professionals who assist childbirth cannot effectively monitor delivery conditions because their knowledge is insufficient. Therefore, we evaluated the knowledge on monitoring the process of childbirth and explored factors which affect the level of knowledge among health care providers in Cambodia.Midwives and nurses were targeted in this study who deal with normal deliveries in the capital city and two provinces. The questionnaire was designed to evaluate if their knowledge on three monitoring aspects is accurate.Of 542 eligible personnel, 523 (96%) participated. The mean score was 58%. Only 3% got scores of more than 90%. According to the statistical analysis, 'working in Kampong Cham province', 'younger age', and 'higher qualification' were significantly associated with higher scores. Previous training experience was not associated with the score.This study found that basic knowledge was low on delivery management among health care providers. We suspect that a deficiency of basic medical knowledge, such as physiology and anatomy, causes the lack of knowledge on the childbirth process. Further intervention should be attempted to improve the knowledge and quality of maternity services in Cambodia.


Assuntos
Parto Obstétrico/normas , Monitorização Fetal/instrumentação , Tocologia/normas , Parto , Cuidado Pós-Natal , Monitorização Uterina/instrumentação , Adulto , Camboja/epidemiologia , Estudos Transversais , Feminino , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Serviços de Saúde Materna , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto , Gravidez
3.
Biomed Eng Online ; 20(1): 26, 2021 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-33726745

RESUMO

BACKGROUND: Fresh stillbirths (FSB) and very early neonatal deaths (VEND) are important global challenges with 2.6 million deaths annually. The vast majority of these deaths occur in low- and low-middle income countries. Assessment of the fetal well-being during pregnancy, labour, and birth is normally conducted by monitoring the fetal heart rate (FHR). The heart rate of newborns is reported to increase shortly after birth, but a corresponding trend in how FHR changes just before birth for normal and adverse outcomes has not been studied. In this work, we utilise FHR measurements collected from 3711 labours from a low and low-middle income country to study how the FHR changes towards the end of the labour. The FHR development is also studied in groups defined by the neonatal well-being 24 h after birth. METHODS: A signal pre-processing method was applied to identify and remove time periods in the FHR signal where the signal is less trustworthy. We suggest an analysis framework to study the FHR development using the median FHR of all measured heart rates within a 10-min window. The FHR trend is found for labours with a normal outcome, neonates still admitted for observation and perinatal mortality, i.e. FSB and VEND. Finally, we study how the spread of the FHR changes over time during labour. RESULTS: When studying all labours, there is a drop in median FHR from 134 beats per minute (bpm) to 119 bpm the last 150 min before birth. The change in FHR was significant ([Formula: see text]) using Wilcoxon signed-rank test. A drop in median FHR as well as an increased spread in FHR is observed for all defined outcome groups in the same interval. CONCLUSION: A significant drop in FHR the last 150 min before birth is seen for all neonates with a normal outcome or still admitted to the NCU at 24 h after birth. The observed earlier and larger drop in the perinatal mortality group may indicate that they struggle to endure the physical strain of labour, and that an earlier intervention could potentially save lives. Due to the low amount of data in the perinatal mortality group, a larger dataset is required to validate the drop for this group.


Assuntos
Monitorização Fetal/instrumentação , Monitorização Fetal/métodos , Frequência Cardíaca Fetal , Trabalho de Parto , Natimorto , Feminino , Coração/fisiopatologia , Humanos , Recém-Nascido , Masculino , Gravidez , Probabilidade , Processamento de Sinais Assistido por Computador
4.
J Chin Med Assoc ; 84(2): 158-164, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-32858548

RESUMO

BACKGROUND: Cardiotocography is a common method of electronic fetal monitoring (EFM) for fetal well-being. Data-driven analyses have shown potential for automated EFM assessment. For this preliminary study, we used a novel artificial intelligence method based on fully convolutional networks (FCNs), with deep learning for EFM evaluation and correct recognition, and its possible role in evaluation of nonreassuring fetal status. METHODS: We retrospectively collected 3239 EFM labor records from 292 deliveries and neonatal Apgar scores between December 2018 and July 2019 at a single medical center. We analyzed these data using an FCN model and compared the results with clinical practice. RESULTS: The FCN model recognized EFM traces like physicians, with an average Cohen's kappa coefficient of agreement of 0.525 and average area under the receiver operating characteristic curve of 0.892 for six fetal heart rate (FHR) categories. The FCN model showed higher sensitivity for predicting fetal compromise (0.528 vs 0.132) but a higher false-positive rate (0.632 vs 0.012) compared with clinical practice. CONCLUSION: FCN is a modern technique that may be useful for EFM trace recognition based on its multiconvolutional layered analysis. Our model showed a competitive ability to identify FHR patterns and the potential for evaluation of nonreassuring fetal status.


Assuntos
Inteligência Artificial , Cardiotocografia/métodos , Monitorização Fetal/instrumentação , Monitorização Fetal/métodos , Frequência Cardíaca Fetal/fisiologia , Adulto , Feminino , Humanos , Auditoria Médica , Gravidez , Estudos Retrospectivos
5.
Midwifery ; 93: 102887, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33260005

RESUMO

OBJECTIVE: Freedom of movement and choice of positioning in labour and birth is known to enhance physiological processes and positive experiences for women during childbirth. Continuous foetal monitoring technologies that enable mobility in labour for women with complex pregnancies, such as wireless CTG, have been marketed for clinical use in most high resource settings since 2003 but there is a paucity of midwifery literature about its clinical use. The aim of this survey was to determine how often, and for whom, wireless and beltless technologies are being used in maternity settings across Australia and New Zealand and to identify any barriers to their uptake. DESIGN: A survey tool developed by Watson et al. (2018) for use in the United Kingdom was adapted for the Australian/New Zealand context. One Maternity Unit Manager or key midwifery clinician from each of 208 public and private hospitals across Australia and New Zealand was invited by email to participate in an online survey between October 2019 and January 2020. Descriptive statistics were used to describe the characteristics of the facilities and the frequency of availability of the monitors. Free text responses were thematically analysed. FINDINGS: The survey received a high (71%) response rate from a range of public and private hospitals in urban and rural settings. Women's freedom of movement and sense of choice and control in labour were seen by most respondents to be positively influenced by wireless monitoring technology. Most facilities reported having at least one wireless or beltless foetal monitor available, however, results suggest that many women consenting to continuous monitoring still do not have access to technology that enables freedom of movement. KEYCONCLUSIONS: Further research is required to explore the barriers and facilitators to enabling freedom of movement and positioning to all women in childbirth, including those women with complex pregnancies who may consent to continuous foetal monitoring.


Assuntos
Desenho de Equipamento/normas , Monitorização Fetal/instrumentação , Limitação da Mobilidade , Adulto , Austrália , Feminino , Monitorização Fetal/normas , Monitorização Fetal/estatística & dados numéricos , Humanos , Nova Zelândia , Gravidez , Complicações na Gravidez , Inquéritos e Questionários
6.
PLoS One ; 15(12): e0242983, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33259507

RESUMO

BACKGROUND: Antepartum fetal monitoring aims to assess fetal development and wellbeing throughout pregnancy. Current methods utilised in clinical practice are intermittent and only provide a 'snapshot' of fetal wellbeing, thus key signs of fetal demise could be missed. Continuous fetal monitoring (CFM) offers the potential to alleviate these issues by providing an objective and longitudinal overview of fetal status. Various CFM devices exist within literature; this review planned to provide a systematic overview of these devices, and specifically aimed to map the devices' design, performance and factors which affect this, whilst determining any gaps in development. METHODS: A systematic search was conducted using MEDLINE, EMBASE, CINAHL, EMCARE, BNI, Cochrane Library, Web of Science and Pubmed databases. Following the deletion of duplicates, the articles' titles and abstracts were screened and suitable papers underwent a full-text assessment prior to inclusion in the review by two independent assessors. RESULTS: The literature searches generated 4,885 hits from which 43 studies were included in the review. Twenty-four different devices were identified utilising four suitable CFM technologies: fetal electrocardiography, fetal phonocardiography, accelerometry and fetal vectorcardiography. The devices adopted various designs and signal processing methods. There was no common means of device performance assessment between different devices, which limited comparison. The device performance of fetal electrocardiography was reduced between 28 to 36 weeks' gestation and during high levels of maternal movement, and increased during night-time rest. Other factors, including maternal body mass index, fetal position, recording location, uterine activity, amniotic fluid index, number of fetuses and smoking status, as well as factors which affected alternative technologies had equivocal effects and require further investigation. CONCLUSIONS: A variety of CFM devices have been developed, however no specific approach or design appears to be advantageous due to high levels of inter-device and intra-device variability.


Assuntos
Monitorização Fetal/instrumentação , Cuidado Pré-Natal , Acelerometria , Eletrocardiografia , Feminino , Movimento Fetal , Idade Gestacional , Frequência Cardíaca Fetal/fisiologia , Humanos , Gravidez , Processamento de Sinais Assistido por Computador
7.
Int J Obstet Anesth ; 44: 16-19, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32679551

RESUMO

Continuous fetal hemodynamic monitoring during in-utero surgery is desirable, but it is often not feasible without intermittent interruption. We report the use of a fetal spiral electrode for continuous heart rate monitoring during fetal myelomeningocele repair. Fetal echocardiography and a fetal spiral electrode were used to monitor fetal heart rate during in-utero repair at 25 weeks' gestation. We observed good agreement between echocardiographic and spiral electrode heart rate measurements. Using the Bland-Altman approach, the mean (SD) difference between measurements was 1.8 (3.5) beats per minute with limits of agreement of -5.3 to 8.8 beats per minute. This case illuminates a potential role for a fetal spiral electrode as a real-time adjunct in fetal interventions.


Assuntos
Ecocardiografia/métodos , Monitorização Fetal/instrumentação , Monitorização Fetal/métodos , Frequência Cardíaca Fetal/fisiologia , Meningomielocele/embriologia , Meningomielocele/cirurgia , Adulto , Eletrodos , Feminino , Humanos , Meningomielocele/diagnóstico por imagem , Gravidez , Ultrassonografia Pré-Natal/métodos
8.
Technol Health Care ; 28(S1): 187-195, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32364151

RESUMO

BACKGROUND: Fetal electrocardiogram (FECG) can be obtained in a non-invasive manner to monitor fetal growth status. OBJECTIVE: In this study, a fetal heart rate (FHR) calculation system was proposed, which consists of the FECG recorder (MF-HOLTER) and the FECG monitoring software (FECG-MS). The abdomen electrocardiogram (AECG) of pregnant woman is acquired through the MF-HOLTER. The FECG-MS packs the AECG data and calls the FECG separation algorithm to obtain the separated FECG and the fetal QRS (FQRS) position. The FHR is further obtained by calculating the R-R interval value. At the same time, this study proposed a FQRS position correction algorithm to calculate the correct FHR values. METHOD: In order to verify the accuracy of the FHR calculation, the ECG signal of FLUKE's PS320 FETAL SIMULATOR and clinical data were simultaneously tested. RESULTS: The accuracy rate is over 98% in processing the simulator's data. In processing clinical data, the FHR values obtained by both the system proposed in this study and Monica AN24 are very close, and the difference is less than 1 bpm. CONCLUSION: The results show that the FHR calculation system is accurate and stable, and has a positive application value and prospect.


Assuntos
Eletrocardiografia Ambulatorial/métodos , Monitorização Fetal/métodos , Frequência Cardíaca Fetal/fisiologia , Processamento de Sinais Assistido por Computador , Monitorização Fetal/instrumentação , Humanos , Processamento de Imagem Assistida por Computador , Reprodutibilidade dos Testes
9.
Acta Obstet Gynecol Scand ; 99(10): 1411-1416, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32274792

RESUMO

INTRODUCTION: Cardiotocography (CTG) is currently the most commonly used method for intrapartum fetal monitoring during labor. However, a high false-positive rate of fetal acidosis indicated by CTG leads to an increase in obstetric interventions. We developed a microdialysis probe that is integrated into a fetal scalp electrode allowing continuous measurement of lactate subcutaneously, thus giving instant information about the oxygenation status of the fetus. Our aim was to establish proof of concept in an animal model using a microdialysis probe to monitor lactate subcutaneously. MATERIAL AND METHODS: We performed an in vivo study in adult male wild-type Wistar rats. We modified electrodes used for CTG monitoring in human fetuses to incorporate a microdialysis membrane. Optimum flow rates for microdialysis were determined in vitro. For the in vivo experiment, a microdialysis probe was inserted into the skin on the back of the animal. De-oxygenation and acidosis were induced by lowering the inspiratory oxygen pressure. Oxygenation and heart rate were monitored. A jugular vein cannula was inserted to draw blood samples for analysis of lactate, pH, pco2 , and saturation. Lactate levels in dialysate were compared with plasma lactate levels. RESULTS: Baseline blood lactate levels were around 1 mmol/L. Upon de-oxygenation, oxygen saturation fell to below 40% for 1 h and blood lactate levels increased 2.5-fold. Correlation of dialysate lactate levels with plasma lactate levels was 0.89 resulting in an R2 of .78 in the corresponding linear regression. CONCLUSIONS: In this animal model, lactate levels in subcutaneous fluid collected by microdialysis closely reflected blood lactate levels upon transient de-oxygenation, indicating that our device is suitable for subcutaneous measurement of lactate. Microdialysis probe technology allows the measurement of multiple compounds in the dialysate, such as glucose, albumin, or inflammatory mediators, so this technique may offer the unique possibility to shed light on fetal physiology during the intrapartum period.


Assuntos
Monitorização Fetal/instrumentação , Lactatos/análise , Membranas Artificiais , Microdiálise , Tela Subcutânea/química , Acidose/diagnóstico , Animais , Feminino , Doenças Fetais/diagnóstico , Monitorização Fetal/métodos , Modelos Animais , Oximetria , Gravidez , Ratos Wistar
10.
Acta Obstet Gynecol Scand ; 99(3): 413-422, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31792930

RESUMO

INTRODUCTION: Noninvasive fetal heart rate monitoring using transabdominal fetal electrocardiographic detection is now commercially available and has been demonstrated to be an effective alternative to traditional Doppler ultrasonographic techniques. Our objective in this study was to compare the results of computerized identification of fetal heart rate patterns generated by ultrasound-based and transabdominal fetal electrocardiogram-based techniques with simultaneously obtained fetal scalp electrode-derived heart rate information. MATERIAL AND METHODS: We applied an objective computer-based analysis for recognition of fetal heart rate patterns (Monica Decision Support) to data obtained simultaneously from a direct fetal scalp electrode, Doppler ultrasound, and the abdominal-fetal electrocardiogram techniques. This allowed us to compare over 145 hours of fetal heart rate patterns generated by the external devices with those derived from the scalp electrode in 30 term singleton uncomplicated pregnancies during labor. The direct fetal scalp electrode is considered to be the most accurate and reliable technique used in current clinical practice, and was, therefore, used as the standard for comparison. The program quantified the baseline heart rate, long- and short-term variability. It indicated when an acceleration or deceleration was present and whether it was large or small. RESULTS: Ultrasound was associated with significantly greater deviations from the fetal scalp electrode results than the abdominal fetal electrocardiogram technique in recognizing the correct baseline heart rate, its variability, and the presence of small and large accelerations and small decelerations. For large decelerations the two external methods were each not significantly different from the scalp electrode results. CONCLUSIONS: Noninvasive fetal heart rate monitoring using maternal abdominal wall electrodes to detect fetal cardiac activity more reliably reproduced the computerized analysis of heart rate patterns derived from a direct fetal scalp electrode than did traditional ultrasound-based monitoring. Abdominal-fetal electrocardiogram should, therefore, be considered a primary option for externally monitored patients.


Assuntos
Eletrocardiografia , Monitorização Fetal/normas , Frequência Cardíaca Fetal , Primeira Fase do Trabalho de Parto , Trabalho de Parto , Ultrassonografia Pré-Natal , Adulto , Feminino , Monitorização Fetal/instrumentação , Humanos , Processamento de Imagem Assistida por Computador , Gravidez , Ultrassonografia Doppler
12.
PLoS One ; 14(7): e0219573, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31291375

RESUMO

BACKGROUND: Intermittent auscultation (IA) is the technique of listening to and counting the fetal heart rate (FHR) for short periods during active labour and continuous cardiotocography (CTC) implies FHR monitoring for longer periods. Although the evidence suggests that IA is the best way to monitor healthy women at low risk of complications, there is no scientific evidence for the ideal device, timing, frequency and duration for IA. We aimed to give an overview of the field, identify and describe methods and practices for performing IA, map the evidence and accuracy for different methods of IA, and identify research gaps. METHODS: We conducted a systematic scoping review following the Joanna Briggs methodology. Medline, EMBASE, Cinahl, Maternity & Infant Care, Cochrane Library, SveMed+, Web of Science, Scopus, Lilacs and African Journals Online were searched for publications up to January 2019. We did hand searches in relevant articles and databases. Studies from all countries, international guidelines and national guidelines from Denmark, United Kingdom, United States, New Zealand, Australia, The Netherlands, Sweden, Denmark, and Norway were included. We did quality assessment of the guidelines according to the AGREEMENT tool. We performed a meta-analysis assessing the effects of IA with a Doppler device vs. Pinard device using methods described in The Cochrane Handbook, and we performed an overall assessment of the summary of evidence using the GRADE approach. RESULTS: The searches generated 6408 hits of which 26 studies and 11 guidelines were included in the review. The studies described slightly different techniques for performing IA, and some did not provide detailed descriptions. Few of the studies provided details of normal and abnormal IA findings. All 11 guidelines recommended IA for low risk women, although they had slightly different recommendations on the frequency, timing, and duration for IA, and the FHR characteristics that should be observed. Four of the included studies, comprising 8436 women and their babies, were randomised controlled trials that evaluated the effect of IA with a Doppler device vs. a Pinard device. Abnormal FHRs were detected more often using the Doppler device than in those using the Pinard device (risk ratio 1.77; 95% confidence interval 1.29-2.43). There were no significant differences in any of the other maternal or neonatal outcomes. Four studies assessed the accuracy of IA findings. Normal FHR was easiest to identify correctly, whereas identifying periodic FHR patterns such as decelerations and saltatory patterns were more difficult. CONCLUSION: Although IA is the recommended method, no trials have been published that evaluate protocols on how to perform it. Nor has any study assessed interrater agreements regarding interpretations of IA findings, and few have assessed to what degree clinicians can describe FHR patterns detected by IA. We found no evidence to recommend Doppler device instead of the Pinard for IA, or vice versa.


Assuntos
Auscultação/métodos , Monitorização Fetal/métodos , Frequência Cardíaca Fetal/fisiologia , Trabalho de Parto/fisiologia , Auscultação/instrumentação , Feminino , Monitorização Fetal/instrumentação , Humanos , Gravidez , Ensaios Clínicos Controlados Aleatórios como Assunto , Estetoscópios , Ultrassonografia Doppler/instrumentação , Ultrassonografia Doppler/métodos
13.
Zhongguo Yi Liao Qi Xie Za Zhi ; 43(3): 162-164, 2019 May 30.
Artigo em Chinês | MEDLINE | ID: mdl-31184069

RESUMO

The existing fetal monitor is prone to false detection in the case of high maternal interference in the second stage of labor. With this background, the article designs and implements a combined maternal-fetal fetal heart monitoring system. The system obtains the Doppler signal of the abdominal fetal heart and the blood oxygen signal of the mother's finger, and estimates the maternal interference degree in the fetal heart rate Doppler signal according to the maximum correlation value between the maternal finger blood oxygen signal and the abdominal fetal heart Doppler signal, and switches the fetal heart rate extraction algorithm between the autocorrelation method suitable for lower interference and improved template method suitable for higher interference according to the maternal interference degree. The accuracy of our method is 9.2% which is higher than that of the improved template matching method and 6.1% higher than that of the autocorrelation method.


Assuntos
Monitorização Fetal , Frequência Cardíaca Fetal , Algoritmos , Eletrocardiografia , Feminino , Monitorização Fetal/instrumentação , Feto , Frequência Cardíaca , Humanos , Gravidez , Processamento de Sinais Assistido por Computador
14.
J Obstet Gynaecol ; 39(8): 1081-1086, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31195856

RESUMO

Small-for-gestational-age (SGA) foetuses are at greater risk of complications than normal foetuses. Studies have demonstrated that foetal electrocardiogram (ECG) device (Monica-AN24) can be employed for monitoring foetal heart rate (FHR). However, its reliability and acceptability has not been assessed in SGA foetuses. This study was aimed at: (a) determining the acceptability of wearing the device more than once, (b) investigating the reliability of acquiring successful FHR data at different gestation. Patients with singleton non-anomalous foetus >24 weeks gestation and an estimated foetal weight below tenth percentile were recruited. Thirty-five women wore the device once. Twenty-four of these wore second time (68.6%). Overall, success-rate of FHR signals was 48.6% and increased to 68.8% beyond 34 weeks gestation. Foetal ECG is a promising method for monitoring SGA foetus >34 weeks gestation. Compared to day recordings, foetal signals were more reliable at night. Further studies are required before its clinical utility can be ascertained. IMPACT STATEMENT What is already known on this subject? Pregnancies that are affected by small-for-gestational-age (SGA) foetus pose a major public health problem and are associated with increased perinatal morbidity and mortality. There is no consensus on the optimal timing of delivery. Current methods employed for monitoring SGA foetuses include ultrasound scans for foetal-biometry and Doppler assessments. However, they provide a snapshot of information on foetal well-being, restrict patient mobility and cannot be employed over long-time periods. It is plausible that ambulatory foetal-ECG device that enable monitoring over a longer time period may better inform decisions about the timing of delivery. What do the results of this study add? Trans-abdominal foetal-ECG is a promising method of monitoring SGA foetus in the home setting with a success rate of acquiring reliable foetal heart rate (FHR) data over 90% at night time. What are the implications of these findings for clinical practice and/or further research? Overall, the study approved the concept of long-term home monitoring and has highlighted the facilitators and barriers to wearing the monitor in clinical care. These observations can be used to undertake robust research to assess the use of foetal-ECG monitor singly or in conjunction with current monitoring techniques for optimal foetal surveillance.


Assuntos
Eletrocardiografia/instrumentação , Monitorização Fetal/instrumentação , Peso Fetal , Frequência Cardíaca Fetal , Adulto , Estudos de Viabilidade , Feminino , Idade Gestacional , Humanos , Satisfação do Paciente , Gravidez , Cuidado Pré-Natal/métodos , Estudos Prospectivos , Inquéritos e Questionários
16.
Sensors (Basel) ; 19(3)2019 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-30678252

RESUMO

In this paper, a fetal electrocardiogram (ECG) monitoring system based on the Android smartphone was proposed. We designed a portable low-power fetal ECG collector, which collected maternal abdominal ECG signals in real time. The ECG data were sent to a smartphone client via Bluetooth. Smartphone app software was developed based on the Android system. The app integrated the fast fixed-point algorithm for independent component analysis (FastICA) and the sample entropy algorithm, for the sake of real-time extraction of fetal ECG signals from the maternal abdominal ECG signals. The fetal heart rate was computed using the extracted fetal ECG signals. Experimental results showed that the FastICA algorithm can extract a clear fetal ECG, and the sample entropy can correctly determine the channel where the fetal ECG is located. The proposed fetal ECG monitoring system may be feasible for non-invasive, real-time monitoring of fetal ECGs.


Assuntos
Algoritmos , Eletrocardiografia/métodos , Monitorização Fetal/métodos , Smartphone , Software , Eletrocardiografia/instrumentação , Feminino , Monitorização Fetal/instrumentação , Humanos , Gravidez , Processamento de Sinais Assistido por Computador , Dispositivos Eletrônicos Vestíveis , Tecnologia sem Fio
17.
Artigo em Inglês | MEDLINE | ID: mdl-30678354

RESUMO

Background: Intrapartum foetal heart rate (FHR) monitoring is crucial for identification of hypoxic foetuses and subsequent interventions. We compared continuous monitoring using a novel nine-crystal FHR monitor (Moyo) versus intermittent single crystal Doppler (Doppler) for the detection of abnormal FHR. Methods: An unmasked randomised controlled study was conducted in a tertiary hospital in Tanzania (ClinicalTrials.gov Identifier: NCT02790554). A total of 2973 low-risk singleton pregnant women in the first stage of labour admitted with normal FHR were randomised to either Moyo (n = 1479) or Doppler (1494) arms. The primary outcome was the proportion of abnormal FHR detection. Secondary outcomes were time intervals in labour, delivery mode, Apgar scores, and perinatal outcomes. Results: Moyo detected abnormal FHR more often (13.3%) compared to Doppler (9.8%) (p = 0.002). Time intervals from admission to detection of abnormal FHR were 15% shorter in Moyo (p = 0.12) and from the detection of abnormal FHR to delivery was 36% longer in Moyo (p = 0.007) compared to the Doppler arm. Time from last FHR to delivery was 12% shorter with Moyo (p = 0.006) compared to Doppler. Caesarean section rates were higher with the Moyo device compared to Doppler (p = 0.001). Low Apgar scores (<7) at the 1st and 5th min were comparable between groups (p = 0.555 and p = 0.800). Perinatal outcomes (fresh stillbirths and 24-h neonatal deaths) were comparable at delivery (p = 0.497) and 24-h post-delivery (p = 0.345). Conclusions: Abnormal FHR detection rates were higher with Moyo compared to Doppler. Moyo detected abnormal FHR earlier than Doppler, but time from detection to delivery was longer. Studies powered to detect differences in perinatal outcomes with timely responses are recommended.


Assuntos
Monitorização Fetal/instrumentação , Determinação da Frequência Cardíaca/instrumentação , Frequência Cardíaca Fetal , Ultrassonografia Doppler/instrumentação , Adulto , Índice de Apgar , Cesárea , Feminino , Humanos , Recém-Nascido , Gravidez , Natimorto , Tanzânia , Centros de Atenção Terciária , Adulto Jovem
18.
J Matern Fetal Neonatal Med ; 32(11): 1762-1768, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29301439

RESUMO

OBJECTIVE: Measurement of fetal scalp blood lactate is a supplementary tool to cardiotocography in the case of a non-reassuring tracing. Several hand-held lactate meters have been launched, all with differentials in absolute values. Therefore, the reference intervals must be calculated for each device. The internationally accepted reference interval is based on measurement with Lactate ProTM with recently got out of production. The aim of this study was to propose cutoffs for normality, preacidemia, and acidemia in fetal scalp blood for Lactate ProTM2 based on the comparison of lactate values measured with Lactate ProTM and Lactate ProTM2. DESIGN: Seven hundred one fetal scalp blood samples were analyzed simultaneously. The conversion equations were retrieved from the linear regression model. On the basis of the cutoffs for Lactate ProTM cutoffs for Lactate ProTM2 were calculated. RESULTS: The conversion equations obtained were Lactate ProTM = -0.02 + 0.68 × Lactate ProTM2 (SD: -0.09-0.07 × Lactate ProTM2) and Lactate proTM2 (LP2) = 0.03 + 1.48 × Lactate ProTM (SD: 0.16 + 0.17 × Lactate ProTM). The correlation to umbilical arterial pH was identical for the two devices (r = -0.18), whereas the correlation to umbilical arterial lactate was better for Lactate ProTM than for Lactate ProTM2 (r = 0.38, respectively, r = 0.33). The correlation to umbilical arterial lactate was dependent on time from sampling to delivery. CONCLUSION: Proposed reference values for Lactate ProTM2: scalp lactate <6.3 mmol/L = normal, no indication for intervention; 6.3-7.1 mmol/L = preacidemia, repeated testing has to be considered; > 7.1 mmol/L = acidemia, expedite delivery.


Assuntos
Acidose Láctica/diagnóstico , Monitorização Fetal/instrumentação , Ácido Láctico/análise , Adolescente , Adulto , Estudos Transversais , Feminino , Humanos , Pessoa de Meia-Idade , Gravidez , Valores de Referência , Adulto Jovem
20.
Sensors (Basel) ; 18(8)2018 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-30104478

RESUMO

This article reviews existing clinical practices and sensor research undertaken to monitor fetal well-being during labour. Current clinical practices that include fetal heart rate monitoring and fetal scalp blood sampling are shown to be either inadequate or time-consuming. Monitoring of lactate in blood is identified as a potential alternative for intrapartum fetal monitoring due to its ability to distinguish between different types of acidosis. A literature review from a medical and technical perspective is presented to identify the current advancements in the field of lactate sensors for this application. It is concluded that a less invasive and a more continuous monitoring device is required to fulfill the clinical needs of intrapartum fetal monitoring. Potential specifications for such a system are also presented in this paper.


Assuntos
Acidose/diagnóstico , Hipóxia Fetal/diagnóstico , Monitorização Fetal/instrumentação , Trabalho de Parto , Feminino , Humanos , Ácido Láctico/sangue , Gravidez , Couro Cabeludo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...