Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Heart Rhythm ; 18(11): 1990-1998, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34339846

RESUMO

BACKGROUND: Subtle differences exist between dog and human, despite use of the dog as a model for cardiac surgical and electrophysiological research. OBJECTIVE: The purpose of this study was to investigate the differences in the atrioventricular conduction axis and adjacent structures between dogs and humans. METHODS: We prepared 33 human and 5 canine hearts for serial histologic sections of the atrioventricular conduction axis, making correlations with gross anatomic findings. We additionally examined and photographed 15 intact normal human hearts obtained from infants undergoing autopsy. Furthermore, we interrogated a computed tomographic dataset from a human adolescent and from 2 autopsied canine hearts, both with normal cardiac anatomy. RESULTS: All canine hearts lacked an inferoseptal recess, with the noncoronary leaflet of the aortic valve and the right fibrous trigone having direct attachments to the septal surface of the left ventricular outflow tract. This correlated with an extensive nonbranching component of the ventricular conduction axis, which skirted half of the noncoronary aortic sinus. This anatomic arrangement was observed in 2 of 15 of autopsied infant hearts. In the human hearts with an inferoseptal recess, the relatively shorter nonbranching bundle is embedded within the fibrous tissue forming its right wall. CONCLUSION: We found a major difference between canine and the majority of human hearts, namely, the presence or absence of an inferoseptal recess. When this recess is absent, as in the canine heart and in some human hearts, a greater proportion of the atrioventricular conduction axis is found within the circumference of the subaortic outflow tract.


Assuntos
Nó Atrioventricular/anatomia & histologia , Anatomia Comparada , Animais , Nó Atrioventricular/diagnóstico por imagem , Cães , Sistema de Condução Cardíaco/anatomia & histologia , Sistema de Condução Cardíaco/diagnóstico por imagem , Humanos , Tomografia Computadorizada por Raios X
2.
Arq. bras. cardiol ; Arq. bras. cardiol;115(1): 71-77, jul. 2020. tab, graf
Artigo em Inglês, Português | LILACS, Sec. Est. Saúde SP | ID: biblio-1131258

RESUMO

Resumo Fundamento O tempo de condução atrioventricular (TCAV) é influenciado pelo estímulo autonômico e sujeito a remodelação fisiológica. Objetivo Avaliar a variabilidade da TCAV batimento-a-batimento e o intervalo RR em atletas e indivíduos sedentários saudáveis. Métodos Vinte adultos, incluindo 10 indivíduos sedentários saudáveis (controles) e 10 corredores de elite de longa distância (atletas), com idade, peso e altura ajustados foram submetidos à avaliação do equivalente metabólico máximo (MET) e registro de ECG em repouso supino de 15 minutos sete dias depois. O intervalo entre os picos da onda P e da onda R definiu o TCAV. Foram calculadas a média (M) e o desvio padrão (DP) de intervalos RR consecutivos (RR) e TCAV acoplados, bem como as linhas de regressão de RR vs. TCAV (RR-TCAV). A condução AV concordante foi definida como o slope RR-AVCT positivo e, caso contrário, discordante. Um modelo de regressão linear multivariada foi desenvolvido para explicar o MET com base nos parâmetros de variabilidade do TCAV e intervalo RR. Nível de significância: 5%. Resultados Nos atletas, os valores de M-RR e DP-RR foram maiores que nos controles, enquanto M-TCAV e DP-TCAV não foram. Os slopes RR-TCAV foram, respectivamente, 0,038 ± 0,022 e 0,0034 ± 0,017 (p < 0,05). Utilizando um valor de corte de 0,0044 (AUC 0,92 ± 0,07; p < 0,001), o slope RR-TCAV mostrou 100% de especificidade e 80% de sensibilidade. Em um modelo multivariado, o slope DP-RR e RR-TCAV foram variáveis explicativas independentes do MET (razão F: 17,2; p < 0,001), apresentando especificidade de 100% e sensibilidade de 90% (AUC: 0,99 ± 0,02; p < 0,001). Conclusão Em corredores de elite, o acoplamento dinâmico de TCAV para intervalo RR apresenta condução AV discordante espontânea, caracterizada por slope na linha de regressão TCAV negativa vs. intervalo RR. O desvio padrão dos intervalos RR e o slope da linha de regressão do TCAV vs. intervalo RR são variáveis explicativas independentes do MET. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Abstract Background Atrioventricular conduction time ( AVCT ) is influenced by autonomic input and subject to physiological remodeling. Objective To evaluate beat-by-beat AVCT and RR-interval variability in athletes and healthy sedentary subjects. Methods Twenty adults, including 10 healthy sedentary (Controls) and 10 elite long-distance runners (Athletes), age, weight and height-adjusted, underwent maximal metabolic equivalent (MET) assessment, and 15-min supine resting ECG recording seven days later. The interval between P-wave and R-wave peaks defined the AVCT . Mean (M) and standard deviation (SD) of consecutive RR-intervals (RR) and coupled AVCT were calculated, as well as regression lines of RR vs. AVCT (RR-AVCT) . Concordant AV conduction was defined as positive RR-AVCT slope and discordant otherwise. A multivariate linear regression model was developed to explain MET based on AVCT and RR-interval variability parameters. Significance-level: 5 %. Results In Athletes, M-RR and SD-RR values were higher than in Controls, whereas M-AVCT and SD-AVCT were not. RR-AVCT slopes were, respectively, 0.038 ± 0.022 and 0.0034 ± 0.017 (p < 0.05). Using a cut-off value of 0.0044 (AUC 0.92 ± 0.07; p < 0.001), RR-AVCT slope showed 100% specificity and 80% sensitivity. In a multivariate model, SD-RR and RR-AVCT slope were independent explanatory variables of MET (F-ratio: 17.2; p < 0.001), showing 100% specificity and 90% sensitivity (AUC 0.99 ± 0.02; p < 0.001). Conclusion In elite runners, AVCT to RR -interval dynamic coupling shows spontaneous discordant AV conduction, characterized by negative AVCT vs. RR -interval regression line slope. RR -intervals standard deviation and AVCT vs. RR -interval regression line slope are independent explanatory variables of MET (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Assuntos
Humanos , Adulto , Nó Atrioventricular/diagnóstico por imagem , Atletas , Sistema Nervoso Autônomo , Modelos Lineares , Eletrocardiografia , Frequência Cardíaca
3.
Arq Bras Cardiol ; 115(1): 71-77, 2020 07.
Artigo em Inglês, Português | MEDLINE | ID: mdl-32401843

RESUMO

Background Atrioventricular conduction time ( AVCT ) is influenced by autonomic input and subject to physiological remodeling. Objective To evaluate beat-by-beat AVCT and RR-interval variability in athletes and healthy sedentary subjects. Methods Twenty adults, including 10 healthy sedentary (Controls) and 10 elite long-distance runners (Athletes), age, weight and height-adjusted, underwent maximal metabolic equivalent (MET) assessment, and 15-min supine resting ECG recording seven days later. The interval between P-wave and R-wave peaks defined the AVCT . Mean (M) and standard deviation (SD) of consecutive RR-intervals (RR) and coupled AVCT were calculated, as well as regression lines of RR vs. AVCT (RR-AVCT) . Concordant AV conduction was defined as positive RR-AVCT slope and discordant otherwise. A multivariate linear regression model was developed to explain MET based on AVCT and RR-interval variability parameters. Significance-level: 5 %. Results In Athletes, M-RR and SD-RR values were higher than in Controls, whereas M-AVCT and SD-AVCT were not. RR-AVCT slopes were, respectively, 0.038 ± 0.022 and 0.0034 ± 0.017 (p < 0.05). Using a cut-off value of 0.0044 (AUC 0.92 ± 0.07; p < 0.001), RR-AVCT slope showed 100% specificity and 80% sensitivity. In a multivariate model, SD-RR and RR-AVCT slope were independent explanatory variables of MET (F-ratio: 17.2; p < 0.001), showing 100% specificity and 90% sensitivity (AUC 0.99 ± 0.02; p < 0.001). Conclusion In elite runners, AVCT to RR -interval dynamic coupling shows spontaneous discordant AV conduction, characterized by negative AVCT vs. RR -interval regression line slope. RR -intervals standard deviation and AVCT vs. RR -interval regression line slope are independent explanatory variables of MET (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0).


Assuntos
Atletas , Nó Atrioventricular , Adulto , Nó Atrioventricular/diagnóstico por imagem , Sistema Nervoso Autônomo , Eletrocardiografia , Frequência Cardíaca , Humanos , Modelos Lineares
4.
Arq. bras. cardiol ; Arq. bras. cardiol;114(2): 284-292, Feb. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1088875

RESUMO

Abstract Background: Diastolic dysfunction, commonly evaluated by echocardiography, is an important early finding in many cardiomyopathies. Cardiac magnetic resonance (CMR) often requires specialized sequences that extends the test time. Recently, feature-tracking imaging has been made available, but still requires expensive software and lacks clinical validation. Objective: To assess diastolic function in patients with aortic valve disease (AVD) and compare it with normal controls by evaluating left ventricular (LV) longitudinal displacement by CMR. Methods: We compared 26 AVD patients with 19 normal controls. Diastolic function was evaluated as LV longitudinal displacement in 4-chamber view cine-CMR images using steady state free precession (SSFP) sequence during the entire cardiac cycle with temporal resolution < 50 ms. The resulting plot of atrioventricular junction (AVJ) position versus time generated variables of AVJ motion. Significance level of p < 0.05 was used. Results: Maximum longitudinal displacement (0.12 vs. 0.17 cm), maximum velocity during early diastole (MVED, 0.6 vs. 1.4s-1), slope of the best-fit line of displacement in diastasis (VDS, 0.22 vs. 0.03s-1), and VDS/MVED ratio (0.35 vs. 0.02) were significantly reduced in AVD patients compared with controls, respectively. Aortic regurgitation showed significantly worse longitudinal LV shortening compared with aortic stenosis. Higher LV mass indicated worse diastolic dysfunction. Conclusions: A simple linear measurement detected significant differences on LV diastolic function between AVD patients and controls. LV mass was the only independent predictor of diastolic dysfunction in these patients. This method can help in the evaluation of diastolic dysfunction, improving cardiomyopathy detection by CMR, without prolonging exam time or depending on expensive software.


Resumo Fundamentos: A disfunção diastólica, comumente avaliada por ecocardiografia, é um importante achado precoce na maioria das cardiomiopatias. A ressonância magnética cardíaca (RMC) frequentemente requer sequências específicas que prolongam o tempo de exame. Recentemente, métodos de imagens com monitoramento de dados (feature-tracking) foram desenvolvidos, mas ainda requerem softwares caros e carecem de validação clínica. Objetivos: Avaliar a função diastólica em pacientes com doença valvar aórtica (DVA) e compará-la a controles normais pela medida do deslocamento longitudinal do ventrículo esquerdo (VE) por RMC. Métodos: Nós comparamos 26 pacientes com DVA com 19 controles normais. A função diastólica foi avaliada como uma medida do deslocamento longitudinal do VE nas imagens de cine-RMC no plano quatro câmaras usando a sequência steady state free precession (SSFP) durante todo o ciclo cardíaco com resolução temporal < 50 ms. O gráfico resultante da posição da junção atrioventricular versus tempo gerou variáveis de movimento da junção atrioventricular. Utilizamos nível de significância de p < 0,005. Resultados: Deslocamento longitudinal máximo (0,12 vs. 0,17 cm), velocidade máxima em início de diástole (0,6 vs. 1,4s-1), velocidade máxima na diástase (0,22 vs. 0,03s-1) e a razão entre a velocidade máxima na diástase e a velocidade máxima em diástole inicial (0,35 vs. 0,02) foram significativamente menores nos pacientes com DVA em comparação aos controles normais, respectivamente. Pacientes com insuficiência aórtica apresentaram medidas de encurtamento longitudinal do VE significativamente piores em comparação aqueles com estenose aórtica. O aumento da massa ventricular esquerda indicou pior disfunção diastólica. Conclusões: Esta simples medida linear detectou diferenças significativas na função diastólica do VE entre pacientes com DVA e controles normais. A massa ventricular esquerda foi o único preditor independente de disfunção diastólica nesses pacientes. Este método pode auxiliar na avaliação da disfunção diastólica, melhorando a detecção de cardiomiopatias por RMC sem prolongar o tempo de exame ou depender de caros softwares.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Diástole/fisiologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Valores de Referência , Nó Atrioventricular/fisiopatologia , Nó Atrioventricular/diagnóstico por imagem , Fatores de Tempo , Fascículo Atrioventricular/fisiopatologia , Fascículo Atrioventricular/diagnóstico por imagem , Estudos de Casos e Controles , Modelos Lineares , Estudos Retrospectivos , Função Ventricular Esquerda/fisiologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Estatísticas não Paramétricas , Imagem Cinética por Ressonância Magnética/métodos
5.
Arq Bras Cardiol ; 114(2): 284-292, 2020 02.
Artigo em Inglês, Português | MEDLINE | ID: mdl-31553387

RESUMO

BACKGROUND: Diastolic dysfunction, commonly evaluated by echocardiography, is an important early finding in many cardiomyopathies. Cardiac magnetic resonance (CMR) often requires specialized sequences that extends the test time. Recently, feature-tracking imaging has been made available, but still requires expensive software and lacks clinical validation. OBJECTIVE: To assess diastolic function in patients with aortic valve disease (AVD) and compare it with normal controls by evaluating left ventricular (LV) longitudinal displacement by CMR. METHODS: We compared 26 AVD patients with 19 normal controls. Diastolic function was evaluated as LV longitudinal displacement in 4-chamber view cine-CMR images using steady state free precession (SSFP) sequence during the entire cardiac cycle with temporal resolution < 50 ms. The resulting plot of atrioventricular junction (AVJ) position versus time generated variables of AVJ motion. Significance level of p < 0.05 was used. RESULTS: Maximum longitudinal displacement (0.12 vs. 0.17 cm), maximum velocity during early diastole (MVED, 0.6 vs. 1.4s-1), slope of the best-fit line of displacement in diastasis (VDS, 0.22 vs. 0.03s-1), and VDS/MVED ratio (0.35 vs. 0.02) were significantly reduced in AVD patients compared with controls, respectively. Aortic regurgitation showed significantly worse longitudinal LV shortening compared with aortic stenosis. Higher LV mass indicated worse diastolic dysfunction. CONCLUSIONS: A simple linear measurement detected significant differences on LV diastolic function between AVD patients and controls. LV mass was the only independent predictor of diastolic dysfunction in these patients. This method can help in the evaluation of diastolic dysfunction, improving cardiomyopathy detection by CMR, without prolonging exam time or depending on expensive software.


Assuntos
Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Diástole/fisiologia , Disfunção Ventricular Esquerda/fisiopatologia , Adulto , Idoso , Insuficiência da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Nó Atrioventricular/diagnóstico por imagem , Nó Atrioventricular/fisiopatologia , Fascículo Atrioventricular/diagnóstico por imagem , Fascículo Atrioventricular/fisiopatologia , Estudos de Casos e Controles , Feminino , Humanos , Modelos Lineares , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Estudos Retrospectivos , Estatísticas não Paramétricas , Fatores de Tempo , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda/fisiologia
6.
Arq Bras Cardiol ; 92(5): 314-9, 330-5, 342-8, 2009 May.
Artigo em Inglês, Mul | MEDLINE | ID: mdl-19629284

RESUMO

BACKGROUND: To study the arterial supply of the conducting system and its correlation with the dominance of the coronary arteries in the South Indian population. OBJECTIVE: To determine angiographically the origins of the sinoatrial nodal artery (SAna) and atrioventricular nodal artery (AVna) in Indians. METHODS: The study included 300 consecutive patients (114 females, 186 males; mean age, 55 years) living in the southern coastal region of India, who underwent coronary angiography either for the symptoms of chest pain, angina pectoris or positive Treadmill Test. The angiograms contained both coronary arteries (right and left) in the right and left anterior oblique position. The origin of SAna and AVna from the coronary arteries was observed and correlated with the arterial dominance. RESULTS: The SA (sinoatrial) node was supplied by the right coronary artery (RCA) in 53% of the cases, by the circumflex (Cx) branch of left coronary artery (LCA) in 42.66%, and by both coronary arteries in 4.33% of cases. The AV (atrioventricular) node was also more often supplied by the RCA (72.33% of cases) than by the Cx branch of the LCA (27.66%), and surprisingly in none of the cases was this node supplied by both coronary arteries. CONCLUSION: The results of the present study may help cardiac surgeons, particularly in surgeries related to certain valvular disorders, due to the proximity of the nodal branches to the valve complex.


Assuntos
Nó Atrioventricular/anatomia & histologia , Circulação Coronária , Vasos Coronários/anatomia & histologia , Nó Sinoatrial/anatomia & histologia , Nó Atrioventricular/diagnóstico por imagem , Feminino , Humanos , Índia , Masculino , Pessoa de Meia-Idade , Radiografia , Nó Sinoatrial/diagnóstico por imagem
7.
Heart ; 81(2): 199-205, 1999 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9922359

RESUMO

OBJECTIVE: To study patients with atrioventricular septal defect to determine the pathognomonic morphological features of the lesion and the relation between the septal structures and the atrioventricular junction. Setting : Tertiary level paediatric cardiology centre. METHODS: Cross sectional echocardiograms from 60 patients were reviewed using qualitative and quantitative analysis. The unifying feature was the presence of a common atrioventricular junction. The overall dimensions of the septal defect were determined and related to the plane of the common junction; the extent of both the atrial and the ventricular septal components was then measured according to the site of closure of the bridging leaflets. RESULTS: In 48 cases, the common junction was guarded by a common valvar orifice, but in 12 cases there were separate right and left valvar orifices. Irrespective of the valvar morphology, no significant difference was found between the groups in terms of the dimensions of the atrial and ventricular septal components. In all patients, the hole permitting shunting at atrial level extended below the plane of the atrioventricular junction, with a variable position of the leading edge of the atrial septum itself. CONCLUSIONS: The atrioventricular junction is a common structure irrespective of valvar morphology. In spite of the presence of unequivocal shunting at atrial level, the atrial septum is usually a well formed structure, even extending in some below the level of the common atrioventricular junction.


Assuntos
Nó Atrioventricular/diagnóstico por imagem , Defeitos dos Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/diagnóstico por imagem , Adolescente , Adulto , Criança , Pré-Escolar , Ecocardiografia , Feminino , Defeitos dos Septos Cardíacos/fisiopatologia , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA