Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.869
Filtrar
1.
Handb Clin Neurol ; 201: 103-126, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38697734

RESUMO

Ulnar neuropathy at the elbow is the second most common compressive neuropathy. Less common, although similarly disabling, are ulnar neuropathies above the elbow, at the forearm, and the wrist, which can present with different combinations of intrinsic hand muscle weakness and sensory loss. Electrodiagnostic studies are moderately sensitive in diagnosing ulnar neuropathy, although their ability to localize the site of nerve injury is often limited. Nerve imaging with ultrasound can provide greater localization of ulnar injury and identification of specific anatomical pathology causing nerve entrapment. Specifically, imaging can now reliably distinguish ulnar nerve entrapment under the humero-ulnar arcade (cubital tunnel) from nerve injury at the retro-epicondylar groove. Both these pathologies have historically been diagnosed as either "ulnar neuropathy at the elbow," which is non-specific, or "cubital tunnel syndrome," which is often erroneous. Natural history studies are few and limited, although many cases of mild-moderate ulnar neuropathy at the elbow appear to remit spontaneously. Conservative management, perineural steroid injections, and surgical release have all been studied in treating ulnar neuropathy at the elbow. Despite this, questions remain about the most appropriate management for many patients, which is reflected in the absence of management guidelines.


Assuntos
Neuropatias Ulnares , Humanos , Neuropatias Ulnares/diagnóstico , Neuropatias Ulnares/terapia , Eletrodiagnóstico/métodos , Nervo Ulnar/fisiopatologia
2.
Acta Orthop Belg ; 90(1): 72-77, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38669653

RESUMO

The standard dorsal portals are the most commonly used in wrist arthroscopy. This cadaveric study aims to determine safe zones, by quantitatively describing the neurovascular relationships of the dorsal wrist arthroscopy portals: 1-2, 3-4, midcarpal radial, midcarpal ulnar, 4-5, 6-radial and 6-ulnar. The neurovascular structures of twenty-one fresh frozen human cadaveric upper limbs were exposed, while the aforementioned portals were established with needles through portal sites. The minimum distance between portals and: dorsal carpal branch of radial artery, superficial branch of radial nerve, posterior interosseous nerve and dorsal branch of ulnar nerve, were measured accordingly with a digital caliper, followed by statistical analysis of the data. The median and interquartile range for each portal to structures at risk were determined and a safe zone around each portal was established. Free of any neurovascular structure safe zones surrounding 1-2, 3-4, midcarpal radial, midcarpal ulnar, 4-5, 6-radial and 6-ulnar portals were found at 0.46mm, 2.33mm, 10.73mm, 11.01mm, 10.38mm, 5.95mm and 0.64mm respectively. Results of statistical analysis from comparisons between 1-2, 3-4 and midcarpal radial portals, indicated that 1-2 was the least safe. The same analysis among 3-4, midcarpal radial, midcarpal ulnar and 4-5 portals indicated that midcarpal portals were safer, while 3-4 was the least safe. Results among midcarpal ulnar, 4-5, 6-radial and 6-ulnar portals indicated that 6-radial and specifically 6-ulnar were the least safe. This study provides a safe approach to the dorsal aspect of the wrist, enhancing established measurements and further examining safety of the posterior interosseous nerve.


Assuntos
Artroscopia , Cadáver , Articulação do Punho , Humanos , Artroscopia/métodos , Articulação do Punho/cirurgia , Articulação do Punho/anatomia & histologia , Nervo Radial/anatomia & histologia , Nervo Ulnar/anatomia & histologia , Masculino , Artéria Radial/anatomia & histologia , Feminino , Idoso
3.
Acta Orthop Belg ; 90(1): 63-66, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38669651

RESUMO

Ulnar nerve release is often performed under general anaesthesia. Wide Awake Local Anaesthesia No Tourniquet (WALANT) is a new anaesthetic method increasingly used by hand surgeons in an outpatient setting. It has advantages such as the possibility to shift surgical interventions out of the regular surgical theatre settings into an outpatient clinical setting, no risk of complications or side effects resulting from regional and general anesthesia and decreased costs. The use of WALANT has not been investigated extensively in elbow surgery. This study aims to evaluate clinical outcomes after ulnar nerve release under WALANT 27 patients with ulnar nerve release for cubital tunnel syndrome were included. The primary outcome was the presence of (remaining) symptoms after ulnar nerve release. Data was extracted from medical records. 13 out of 27 patients had (mild) remaining symptoms after ulnar nerve release, and 1 complication (superficial wound infection) was seen. Ulnar nerve release under WALANT is safe and effective in patients with primary ulnar nerve entrapment that have failed conservative therapy.


Assuntos
Procedimentos Cirúrgicos Ambulatórios , Anestesia Local , Anestésicos Locais , Síndrome do Túnel Ulnar , Humanos , Anestesia Local/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Síndrome do Túnel Ulnar/cirurgia , Adulto , Procedimentos Cirúrgicos Ambulatórios/métodos , Anestésicos Locais/administração & dosagem , Idoso , Nervo Ulnar/cirurgia , Torniquetes , Resultado do Tratamento , Estudos Retrospectivos
4.
Microsurgery ; 44(4): e31178, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38661385

RESUMO

BACKGROUND: Transfer of the fascicle carrying the flexor carpi ulnaris (FCU) branch of the ulnar nerve (UN) to the biceps/brachialis muscle branch of the musculocutaneous nerve (Oberlin's procedure), is a mainstay technique for elbow flexion restoration in patients with upper brachial plexus injury. Despite its widespread use, there are few studies regarding the anatomic location of the donor fascicle for Oberlin's procedure. Our report aims to analyze the anatomical variability of this fascicle within the UN, while obtaining quantifiable, objective data with intraoperative neuromonitoring (IONM) for donor fascicle selection. METHODS: We performed a retrospective review of patients at our institution who underwent an Oberlin's procedure from September 2019 to July 2023. We used IONM for donor fascicle selection (greatest FCU muscle and least intrinsic hand muscle activation). We prospectively obtained demographic and electrophysiological data, as well as anatomical location of donor fascicles and post-surgical morbidities. Surgeon's perception of FCU/intrinsic muscle contraction was compared to objective muscle amplitude during IONM. RESULTS: Eight patients were included, with a mean age of 30.5 years and an injury-to-surgery interval of 4 months. Donor fascicle was located anterior in two cases, posterior in two, radial in two and ulnar in two patients. Correlation between surgeon's perception and IONM findings were consistent in six (75%) cases. No long term motor or sensory deficits were registered. CONCLUSIONS: Fascicle anatomy within the UN at the proximal arm is highly variable. The use of IONM can aid in optimizing donor fascicle selection for Oberlin's procedure.


Assuntos
Monitorização Neurofisiológica Intraoperatória , Transferência de Nervo , Nervo Ulnar , Humanos , Estudos Retrospectivos , Adulto , Masculino , Feminino , Nervo Ulnar/cirurgia , Nervo Ulnar/anatomia & histologia , Transferência de Nervo/métodos , Monitorização Neurofisiológica Intraoperatória/métodos , Plexo Braquial/anatomia & histologia , Plexo Braquial/cirurgia , Plexo Braquial/lesões , Músculo Esquelético , Adulto Jovem , Neuropatias do Plexo Braquial/cirurgia , Pessoa de Meia-Idade
5.
J Pediatr Orthop ; 44(5): e426-e432, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38454784

RESUMO

OBJECTIVE: This work aimed to evaluate the results of using a 2-stage surgical treatment strategy without doing anterior transposition of the ulnar nerve (ATUN) for cases with long-standing nonunited fracture lateral humeral condyle (LHC) in children, accompanied by a critical review. METHODS: A consecutive 12 children with a long-standing ">2 years" nonunited LHC with evident radiologic gross anatomic distortion of the elbow were included in this study. A 2-stage surgical treatment strategy was applied, wherein the first stage, open functional reduction, osteosynthesis, and iliac bone graft were done. Then after 6 months, the second stage surgery was carried out in the form of supracondylar humeral corrective osteotomy if the cubitus valgus angle was ≥20 degrees. ATUN was not done for any of the cases even with those having ulnar nerve dysfunction. RESULTS: Union took place in 11 out of the 12 cases after a mean follow-up period of 11 weeks (range: 8 to 14 wk; SD: 1.6). All the 7 cases showed preoperative ulnar nerve dysfunction and reported clinical recovery at the end of their follow-up. CONCLUSIONS: Two-stage surgical treatment strategy without ATUN is a convenient, reproducible, and successful line of treatment for children presented with longstanding nonunited LHC with anatomically distorted elbow. LEVEL OF EVIDENCE: Level IV-case series.


Assuntos
Articulação do Cotovelo , Fraturas não Consolidadas , Fraturas do Úmero , Criança , Humanos , Fraturas do Úmero/diagnóstico por imagem , Fraturas do Úmero/cirurgia , Fraturas do Úmero/complicações , Úmero/cirurgia , Nervo Ulnar , Fixação Interna de Fraturas/métodos , Fraturas não Consolidadas/cirurgia , Articulação do Cotovelo/cirurgia , Resultado do Tratamento , Amplitude de Movimento Articular/fisiologia , Estudos Retrospectivos
6.
Med Eng Phys ; 125: 104127, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38508804

RESUMO

The monitoring of the neuromuscular blockade is critical for patient's safety during and after surgery. The monitoring of neuromuscular blockade often requires the use of Train of Four (TOF) technique. During a TOF test two electrodes are attached to the ulnar nerve, and a series of four electric pulses are applied. The electrical stimulation causes the thumb to twitch, and the amount of twitch varies depending on the amount of neuromuscular blockade in patient's system. Current medical devices used to assist anesthesiologists to perform TOF monitoring often require free hand movement and do not provide accurate or reliable results. The goal of this work is to design, prototype and test a new medical device that provides reliable TOF results when thumb movement is restricted. A medical device that uses a pressurized catheter balloon to detect the response thumb twitch of the TOF test is created. An analytical model, numerical study, and mechanical finger testing were employed to create an optimum design. The design is tested through a pilot human subjects study. No significant correlation is reported with subjects' properties, including hand size.


Assuntos
Bloqueio Neuromuscular , Fármacos Neuromusculares não Despolarizantes , Humanos , Monitoração Neuromuscular/métodos , Nervo Ulnar/fisiologia , Estimulação Elétrica
7.
Clin Neurophysiol ; 161: 180-187, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38520798

RESUMO

OBJECTIVE: To measure neuromagnetic fields of ulnar neuropathy patients at the elbow after electrical stimulation and evaluate ulnar nerve function at the elbow with high spatial resolution. METHODS: A superconducting quantum interference device magnetometer system recorded neuromagnetic fields of the ulnar nerve at the elbow after electrical stimulation at the wrist in 16 limbs of 16 healthy volunteers and 21 limbs of 20 patients with ulnar neuropathy at the elbow. After artifact removal, neuromagnetic field signals were processed into current distributions, which were superimposed onto X-ray images for visualization. RESULTS: Based on the results in healthy volunteers, conduction velocity of 30 m/s or 50% attenuation in current amplitude was set as the reference value for conduction disturbance. Of the 21 patient limbs, 15 were measurable and lesion sites were detected, whereas 6 limbs were unmeasurable due to weak neuromagnetic field signals. Seven limbs were deemed normal by nerve conduction study, but 5 showed conduction disturbances on magnetoneurography. CONCLUSIONS: Measuring the magnetic field after nerve stimulation enabled visualization of neurophysiological activity in patients with ulnar neuropathy at the elbow and evaluation of conduction disturbances. SIGNIFICANCE: Magnetoneurography may be useful for assessing lesion sites in patients with ulnar neuropathy at the elbow.


Assuntos
Cotovelo , Condução Nervosa , Nervo Ulnar , Neuropatias Ulnares , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Neuropatias Ulnares/fisiopatologia , Neuropatias Ulnares/diagnóstico , Neuropatias Ulnares/diagnóstico por imagem , Condução Nervosa/fisiologia , Cotovelo/fisiopatologia , Cotovelo/inervação , Cotovelo/diagnóstico por imagem , Idoso , Nervo Ulnar/fisiopatologia , Nervo Ulnar/diagnóstico por imagem , Estimulação Elétrica/métodos , Campos Magnéticos
8.
J Neurosci Methods ; 406: 110116, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38548122

RESUMO

BACKGROUND: Little research exists on extending ex-vivo systems to large animal nerves, and to the best of our knowledge, there has yet to be a study comparing these against in-vivo data. This paper details the first ex-vivo system for large animal peripheral nerves to be compared with in-vivo results. NEW METHOD: Detailed ex-vivo and in-vivo closed-loop neuromodulation experiments were conducted on pig ulnar nerves. Temperatures from 20 °C to 37 °C were evaluated for the ex-vivo system. The data were analysed in the time and velocity domains, and a regression analysis established how evoked compound action potential amplitude and modal conduction velocity (CV) varied with temperature and time after explantation. MAIN RESULTS: Pig ulnar nerves were sustained ex-vivo up to 5 h post-explantation. CV distributions of ex-vivo and in-vivo data were compared, showing closer correspondence at 37 °C. Regression analysis results also demonstrated that modal CV and time since explantation were negatively correlated, whereas modal CV and temperature were positively correlated. COMPARISON WITH EXISTING METHODS: Previous ex-vivo systems were primarily aimed at small animal nerves, and we are not aware of an ex-vivo system to be directly compared with in-vivo data. This new approach provides a route to understand how ex-vivo systems for large animal nerves can be developed and compared with in-vivo data. CONCLUSION: The proposed ex-vivo system results were compared with those seen in-vivo, providing new insights into large animal nerve activity post-explantation. Such a system is crucial for complementing in-vivo experiments, maximising collected experimental data, and accelerating neural interface development.


Assuntos
Condução Nervosa , Nervo Ulnar , Animais , Suínos , Nervo Ulnar/fisiologia , Condução Nervosa/fisiologia , Potenciais de Ação/fisiologia , Temperatura , Estimulação Elétrica/métodos
9.
J Ultrasound Med ; 43(6): 1153-1173, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38444253

RESUMO

This is the second part of a two-part article in which we focus on the ultrasound (US) appearance of the pathological ulnar nerve (UN) and its main branches. Findings in a wide range of our pathological cases are presented with high-resolution US images obtained with the latest-generation US machines and transducers.


Assuntos
Nervo Ulnar , Ultrassonografia , Humanos , Nervo Ulnar/diagnóstico por imagem , Ultrassonografia/métodos , Neuropatias Ulnares/diagnóstico por imagem
10.
World Neurosurg ; 185: e1182-e1191, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38508385

RESUMO

BACKGROUND: The brachial plexus is a network of nerves located between the neck and axilla, which receives input from C5-T1. Distally, the nerves and blood vessels that supply the arm and forearm form a medial neurovascular bundle. The purpose of this study was to illustrate that a peripheral nerve dissection via a 2 × 2 inch window would allow for identification and isolation of the major nerves and blood vessels that supply the arm and forearm. METHODS: A right side formalin-fixed latex-injected cadaveric arm was transected at the proximal part of the axillary fold and included the scapular attachments. Step-by-step anatomical dissection was carried out and documented with three-dimensional digital imaging. RESULTS: A 2 × 2 inch window centered 2 inches distal to the axillary fold on the medial surface of the arm enabled access to the major neurovascular structures of the arm and forearm: the median nerve, ulnar nerve, medial antebrachial cutaneous nerve, radial nerve and triceps motor branches, musculocutaneous nerve and its biceps and brachialis branches and lateral antebrachial cutaneous nerve, basilic vein and brachial artery and vein, and profunda brachii artery. CONCLUSIONS: Our study demonstrates that the majority of the neurovascular supply in the arm and forearm can be accessed through a 2 × 2 inch area in the medial arm. Although this "key window" may not be entirely utilized in the operative setting, our comprehensive didactic description of peripheral nerve dissection in the cadaver laboratory can help in safer identification of complex anatomy encountered during surgical procedures.


Assuntos
Cadáver , Extremidade Superior , Humanos , Extremidade Superior/inervação , Extremidade Superior/irrigação sanguínea , Dissecação , Plexo Braquial/anatomia & histologia , Nervo Mediano/anatomia & histologia , Nervo Ulnar/anatomia & histologia
11.
Handchir Mikrochir Plast Chir ; 56(1): 101-105, 2024 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-38359863

RESUMO

INTRODUCTION: A supracondylar process is a bony spur on the distal anteromedial surface of the humerus, and it is considered an anatomical variant with a prevalence of 0.4-2.7% according to anatomical studies. In almost all cases, it is associated with a fibrous, sometimes ossified ligament, which extends from the supracondylar process to the medial epicondyle. This ligament is known in the literature as the ligament of Struthers, named after the Scottish anatomist who first described it in detail in 1854. In rare cases, the supracondylar process can be a clinically relevant finding as a cause of nerve compression syndrome. The median and ulnar nerve can be trapped by the ring-shaped structure formed by the ligament of Struthers and the supracondylar process. CASE REPORT: A 59-year-old patient with symptoms of a cubital tunnel syndrome and additional ipsilateral sensory deficits in his thumb was referred to our clinic. Electroneurography showed no signs of an additional carpal tunnel syndrome. Preoperative x-ray and CT scans of the upper arm revealed a supracondylar process, which led us to suspect an associated entrapment of the median nerve. An MRI scan of the upper arm showed a ligament of Struthers and signs of a related median nerve compression as we initially assumed. We performed a surgical decompression of the median nerve in the distal upper arm and of the ulnar nerve in the cubital tunnel. Intraoperatively, there was evidence of compression of the median nerve due to the supracondylar process and the ligament of Struthers. The latter was cleaved and then resected along with the supracondylar process. Three months after surgery, the patient had no motor or sensory deficits. SUMMARY: The ring-shaped structure formed by the supracondylar process and ligament of Struthers represents a rare cause of compression syndrome of the median and ulnar nerve. Its incidence remains unknown so far. This anatomical variant should be considered a differential diagnosis in case of possibly related nerve entrapment symptoms after ruling out other, more frequent nerve compression causes. Moreover, the supracondylar process should be completely resected including the periosteum during surgery to minimise the risk of recurrence.


Assuntos
Síndrome do Túnel Carpal , Síndromes de Compressão Nervosa , Humanos , Pessoa de Meia-Idade , Nervo Mediano/cirurgia , Ligamentos/cirurgia , Úmero/diagnóstico por imagem , Úmero/cirurgia , Úmero/inervação , Braço , Nervo Ulnar/cirurgia , Síndrome do Túnel Carpal/diagnóstico , Síndrome do Túnel Carpal/etiologia , Síndrome do Túnel Carpal/cirurgia , Síndromes de Compressão Nervosa/diagnóstico , Síndromes de Compressão Nervosa/etiologia , Síndromes de Compressão Nervosa/cirurgia
12.
Muscle Nerve ; 69(5): 543-547, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38356457

RESUMO

INTRODUCTION/AIMS: Ulnar nerve instability (UNI) in the retroepicondylar groove is described as nerve subluxation or dislocation. In this study, considering that instability may cause chronic ulnar nerve damage by increasing the friction risk, we aimed to examine the effects of UNI on nerve morphology ultrasonographically. METHODS: Asymptomatic patients with clinical suspicion of UNI were referred for further clinical and ultrasonographic examination. Based on ulnar nerve mobility on ultrasound, the patients were first divided into two groups: stable and unstable. The unstable group was further divided into two subgroups: subluxation and dislocation. The cross-sectional area (CSA) of the nerve was measured in three regions relative to the medial epicondyle (ME). RESULTS: In the ultrasonographic evaluation, UNI was identified in 59.1% (52) of the 88 elbows. UNI was bilateral in 50% (22) of the 44 patients. Mean CSA was not significantly different between groups. A statistically significant difference in ulnar nerve mobility was found between the group with CSA of <10 versus ≥10 mm2 (p = .027). Nerve instability was found in 85.7% of elbows with an ulnar nerve CSA value of ≥10 mm2 at the ME level. DISCUSSION: The probability of developing neuropathy in patients with UNI may be higher than in those with normal nerve mobility. Further prospective studies are required to elucidate whether asymptomatic individuals with UNI and increased CSA may be at risk for developing symptomatic ulnar neuropathy at the elbow.


Assuntos
Articulação do Cotovelo , Neuropatias Ulnares , Humanos , Nervo Ulnar/diagnóstico por imagem , Neuropatias Ulnares/diagnóstico por imagem , Cotovelo/diagnóstico por imagem , Articulação do Cotovelo/inervação , Ultrassonografia
13.
J Hand Surg Am ; 49(4): 346-353, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38323947

RESUMO

PURPOSE: Microsuture neurorrhaphy is technically challenging and has inherent drawbacks. This study evaluated the potential of a novel, sutureless nerve coaptation device to improve efficiency and precision. METHODS: Twelve surgeons participated in this study-six attending hand/microsurgeons and six trainees (orthopedic and plastic surgery residents or hand surgery fellows). Twenty-four cadaver arm specimens were used, and nerve repairs were performed at six sites in each specimen-the median and ulnar nerves in the proximal forearm, the median and ulnar nerves in the distal forearm, and the common digital nerves to the second and third web spaces. Each study participant performed nerve repairs at all six injury locations in two different cadaver arms (n = 12 total repairs for each participating surgeon). The nerve repairs were timed, tested for tensile strength, and graded for alignment and technical repair quality. RESULTS: A substantial reduction in time was required to perform repairs with the novel coaptation device (1.6 ± 0.8 minutes) compared with microsuture (7.2 ± 3.6 minutes). Device repairs were judged clinically acceptable (scoring "Excellent" or "Good" by most of the expert panel) in 97% of the repairs; the percentage of suture repairs receiving Excellent/Good scores by most of the expert panel was 69.4% for attending surgeons and 36.1% for trainees. The device repairs exhibited a higher average peak tensile force (7.0 ± 3.6 N) compared with suture repairs (2.6 ± 1.6 N). CONCLUSIONS: Nerve repairs performed with a novel repair device were performed faster and with higher technical precision than those performed using microsutures. Device repairs had substantially greater tensile strength than microsuture repairs. CLINICAL RELEVANCE: The evaluated novel nerve repair device may improve surgical efficiency and nerve repair quality.


Assuntos
Mãos , Nervos Periféricos , Humanos , Nervos Periféricos/cirurgia , Mãos/cirurgia , Nervo Ulnar/cirurgia , Braço , Cadáver , Técnicas de Sutura
14.
Surg Radiol Anat ; 46(4): 473-482, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38329521

RESUMO

PURPOSE: Anatomical variations of the concave shaped retrocondylar ulnar groove (RUG) can contribute to ulnar nerve instability. However, there are currently limited available standardized data describing the anatomy of the RUG based on radiologic imaging, such as computed tomography (CT). This study aims to provide a comprehensive description and classification of RUG anatomy based on RUG angle measurements. METHODS: 400 CT scans of the elbows of adults showing no signs of osseous damage were evaluated. RUG angles were measured in four anatomically defined axial planes that spanned from the proximal to the distal end of the RUG. Furthermore, distance measurements at the medial epicondyle were conducted. A classification system for the RUG is proposed based on the acquired RUG angles, aiming to categorize the individual angles according to the 25th and 75th percentiles. RESULTS: RUG angles were significantly larger in males compared to females (p < 0.001) accompanied by larger distances including the off-set and height of the medial epicondyle (p < 0.001). RUG angles decreased from proximal to distal locations (p < 0.05). CONCLUSION: This study revealed that men exhibited larger RUG angles compared to women, indicating a less-concave shape of the RUG in men. Introducing an objective RUG classification system can improve our understanding of anatomical variations and potentially find application in diagnostics and preoperative planning.


Assuntos
Articulação do Cotovelo , Nervo Ulnar , Masculino , Adulto , Humanos , Feminino , Nervo Ulnar/anatomia & histologia , Articulação do Cotovelo/anatomia & histologia , Cotovelo/inervação , Tomografia Computadorizada por Raios X
15.
Sci Rep ; 14(1): 4643, 2024 02 26.
Artigo em Inglês | MEDLINE | ID: mdl-38409319

RESUMO

To date, little is known about the usefulness of ultra-high frequency ultrasound (UHF-US, 50-70 MHz) in clinical practice for the diagnosis of dysimmune neuropathies. We present a prospective study aimed at comparing UHF-US alterations of nerves and fascicles in chronic inflammatory demyelinating polyradiculoneuropathy (CIDP), distal CIDP (d-CIDP) and anti-MAG neuropathy and their relationships with clinical and electrodiagnostic (EDX) features. 28 patients were included (twelve CIDP, 6 d-CIDP and 10 anti-MAG) and ten healthy controls. Each patient underwent neurological examination, EDX and UHF-US study of median and ulnar nerves bilaterally. UHF-US was reliable in differentiating immune neuropathies from controls when using mean and/or segmental nerve and/or fascicle cross-sectional area (CSA); furthermore, fascicle ratio (fascicle/nerve CSA) was a reliable factor for differentiating d-CIDP from other types of polyneuropathies. The fascicle CSA appears to be more increased in CIDP and its variant than in anti-MAG neuropathy. UHF-US offers information beyond simple nerve CSA and allows for a better characterization of the different forms of dysimmune neuropathies.


Assuntos
Polineuropatias , Polirradiculoneuropatia Desmielinizante Inflamatória Crônica , Humanos , Polirradiculoneuropatia Desmielinizante Inflamatória Crônica/diagnóstico por imagem , Estudos Prospectivos , Ultrassonografia , Nervo Ulnar/diagnóstico por imagem , Glicoproteína Associada a Mielina , Autoanticorpos , Nervos Periféricos/diagnóstico por imagem , Condução Nervosa
16.
J Shoulder Elbow Surg ; 33(5): 1092-1103, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38286182

RESUMO

BACKGROUND: Ulnar neuropathy at the elbow caused by heterotopic ossification (HO) is a rare condition. This retrospective study aims to report on 32 consecutive cases of ulnar nerve encasement caused by elbow HO and evaluate long-term outcomes of operative management and a standardized postoperative rehabilitation regimen. METHODS: A retrospective case series was conducted on 32 elbows (27 patients) that underwent operative management of bony ulnar nerve encasement. All procedures were performed in the inpatient setting at an Academic Level 1 Trauma Center from September 1999 to July 2021 by one of 3 fellowship-trained shoulder and elbow. Postoperatively, all patients received formal physical therapy, HO prophylaxis (30 received indomethacin, 2 received radiation), and a structured continuous passive motion machine regimen. Patient demographics, age, gender, type of injury, history of tobacco use, and medical comorbidities were obtained to include in the analysis. Long-term follow-up examinations were performed to evaluate elbow flexion-extension arc of motion, Mayo Elbow Performance Score, and visual analog scale pain scores. RESULTS: Thirty-two elbows with complete bony ulnar nerve encasement secondary to HO were identified (14 from burns, 15 from trauma, 3 closed head injuries). Following surgery, the mean flexion-extension arc of motion improved significantly, increasing from 21° to 100° at long-term follow-up (average 8.7 years, range 2-17 years), with statistically significant improvements in preoperative vs. long-term postoperative elbow extension (P < .001), flexion (P < .001), and total arc of motion (P < .001). There was a statistically significant improvement in pre- vs. postprocedure ulnar nerve function, as demonstrated by a decrease in average McGowan grade (1.2-0.7; P = .002). Additionally, 63% of patients with preoperative ulnar neuropathy symptoms (20/32) had either complete resolution or subjective improvement after surgery. The mean time from injury to surgery was 518 days (range 65-943 days). Age, gender, time to surgery, and medical comorbidities were not associated with outcomes. The complication rate was 9% (3/32). Patients had an average flexion-extension arc of motion of 97° and average Mayo Elbow Performance Score of 80 ("good") at long-term follow-up. CONCLUSIONS: The combination of operative management, postoperative HO prophylaxis, and a regimented rehabilitation program has proven to be a durable solution for treating and ensuring good long-term functional outcomes for patients with elbow HO and bony ulnar nerve encasement. This treatment approach leads to superior range of motion, improved or resolved ulnar neuropathy, and good to excellent long-term functional outcomes.


Assuntos
Articulação do Cotovelo , Ossificação Heterotópica , Neuropatias Ulnares , Humanos , Cotovelo/cirurgia , Nervo Ulnar/cirurgia , Estudos Retrospectivos , Articulação do Cotovelo/cirurgia , Neuropatias Ulnares/etiologia , Ossificação Heterotópica/etiologia , Ossificação Heterotópica/cirurgia , Ossificação Heterotópica/diagnóstico , Amplitude de Movimento Articular/fisiologia , Resultado do Tratamento
17.
JBJS Case Connect ; 14(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38207087

RESUMO

CASES: We present 2 cases of median nerve reconstruction using distal nerve transfers after resection of unusual benign median nerve tumors. Critical sensation was restored in case 1 by transferring the fourth common digital nerve to first web digital nerves. Thumb opposition was regained by transferring the abductor digiti minimi ulnar motor nerve branch to the recurrent median motor nerve branch. Critical sensation was restored in case 2 by transferring the long finger ulnar digital nerve to the index finger radial digital nerve. CONCLUSION: Distal nerve transfers, even with short grafts, are reliable median nerve deficit treatments, sparing the need for larger autologous nerve grafts and late tendon opponensplasties.


Assuntos
Nervo Mediano , Transferência de Nervo , Humanos , Nervo Mediano/cirurgia , Dedos/cirurgia , Dedos/inervação , Nervo Ulnar/cirurgia , Nervo Radial/cirurgia
18.
Bone Joint J ; 106-B(2): 212-218, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38295855

RESUMO

Aims: Medial humeral epicondyle fractures (MHEFs) are common elbow fractures in children. Open reduction should be performed in patients with MHEF who have entrapped intra-articular fragments as well as displacement. However, following open reduction, transposition of the ulnar nerve is disputed. The aim of this study is to evaluate the need for ulnar nerve exploration and transposition. Methods: This was a retrospective cohort study. The clinical data of patients who underwent surgical treatment of MHEF in our hospital from January 2015 to January 2022 were collected. The patients were allocated to either transposition or non-transposition groups. Data for sex, age, cause of fracture, duration of follow-up, Papavasiliou and Crawford classification, injury-to-surgery time, preoperative ulnar nerve symptoms, intraoperative exploration of ulnar nerve injury, surgical incision length, intraoperative blood loss, postoperative ulnar nerve symptoms, complications, persistent ulnar neuropathy, and elbow joint function were analyzed. Binary logistic regression analysis was used for statistical analysis. Results: A total of 124 patients were followed up, 50 in the ulnar nerve transposition group and 74 in the non-transposition group. There were significant differences in ulnar nerve injury (p = 0.009), incision length (p < 0.001), and blood loss (p = 0.003) between the two groups. Binary logistic regression analysis revealed that preoperative ulnar nerve symptoms (p = 0.012) were risk factors for postoperative ulnar nerve symptoms. In addition, ulnar nerve transposition did not affect the occurrence of postoperative ulnar nerve symptoms (p = 0.468). Conclusion: Ulnar nerve transposition did not improve clinical outcomes. It is recommended that the ulnar nerve should not be transposed when treating MHEF operatively.


Assuntos
Fraturas do Úmero , Nervo Ulnar , Criança , Humanos , Nervo Ulnar/cirurgia , Estudos Retrospectivos , Fraturas do Úmero/cirurgia , Cotovelo , Úmero , Resultado do Tratamento
19.
Neuroradiol J ; 37(2): 137-151, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36961518

RESUMO

The ulnar nerve is the second most commonly entrapped nerve after the median nerve. Although clinical evaluation and electrodiagnostic studies remain widely used for the evaluation of ulnar neuropathy, advancements in imaging have led to increased utilization of these newer / better imaging techniques in the overall management of ulnar neuropathy. Specifically, high-resolution ultrasonography of peripheral nerves as well as MRI has become quite useful in evaluating the ulnar nerve in order to better guide treatment. The caliber and fascicular pattern identified in the normal ulnar nerves are important distinguishing features from ulnar nerve pathology. The cubital tunnel within the elbow and Guyon's canal within the wrist are important sites to evaluate with respect to ulnar nerve compression. Both acute and chronic conditions resulting in deformity, trauma as well as inflammatory conditions may predispose certain patients to ulnar neuropathy. Granulomatous diseases as well as both neurogenic and non-neurogenic tumors can also potentially result in ulnar neuropathy. Tumors around the ulnar nerve can also lead to mass effect on the nerve, particularly in tight spaces like the aforementioned canals. Although high-resolution ultrasonography is a useful modality initially, particularly as it can be helpful for dynamic evaluation, MRI remains most reliable due to its higher resolution. Newer imaging techniques like sonoelastography and microneurography, as well as nerve-specific contrast agents, are currently being investigated for their usefulness and are not routinely being used currently.


Assuntos
Neoplasias , Síndromes de Compressão do Nervo Ulnar , Neuropatias Ulnares , Humanos , Nervo Ulnar/diagnóstico por imagem , Nervo Ulnar/patologia , Punho/patologia , Síndromes de Compressão do Nervo Ulnar/diagnóstico por imagem , Síndromes de Compressão do Nervo Ulnar/patologia , Neuropatias Ulnares/diagnóstico por imagem
20.
J Shoulder Elbow Surg ; 33(5): 1185-1199, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38072032

RESUMO

BACKGROUND: Elbow medial ulnar collateral ligament (mUCL) injuries have become increasingly common, leading to a higher number of mUCL reconstructions (UCLR). Various techniques and graft choices have been reported. The purpose of this study was to evaluate the prevalence of each available graft choice, the surgical techniques most utilized, and the reported complications associated with each surgical method. METHODS: A systematic review was performed using the Preferred Reporting Items for Systematic Reviews and Meta-Analysesguidelines. We queried PubMed/MEDLINE, Embase, Web of Science, and Cochrane databases to identify all articles that included UCLR between January 2002 and October 2022. We included all studies that referenced UCLR graft choice, surgical technique, and/or ulnar nerve transposition. Studies were evaluated in a narrative fashion to assess demographics and report current trends in utilization and complications of UCLR as they pertain to graft choice and surgical techniques over the past 20 years. Where possible, we stratified based on graft and technique. RESULTS: Forty-seven articles were included, reporting on 6671 elbows. The cohort was 98% male, had a weighted mean age of 21 years and follow-up of 53 months. There were 6146 UCLRs (92%) performed with an autograft and 152 (2.3%) that utilized an allograft, while 373 (5.6%) were from mixed cohorts of autograft and allograft. Palmaris longus autograft was the most utilized mUCL graft choice (64%). The most utilized surgical configuration was the figure-of-8 (68%). Specifically, the most common techniques were the modified Jobe technique (37%), followed by American Sports Medicine Institute (ASMI) (22%), and the docking (22%) technique. A concomitant ulnar nerve transposition was performed in 44% of all patients, with 1.9% of these patients experiencing persistent ulnar nerve symptoms after ulnar nerve transposition. Of the total cohort, 14% experienced postoperative ulnar neuritis with no prior preoperative ulnar nerve symptoms. Further, meta-analysis revealed a significantly greater revision rate with the use of allografts compared to autograft and mixed cohorts (2.6% vs. 1.8% and 1.9%, P = .003). CONCLUSIONS: Most surgeons performed UCLR with palmaris autograft utilizing a figure-of-8 graft configuration, specifically with the modified Jobe technique. The overall rate of allograft use was 2.3%, much lower than expected. The revision rate for UCLR with allograft appears to be greater compared to UCLR with autograft, although this may be secondary to limited allograft literature.


Assuntos
Beisebol , Ligamento Colateral Ulnar , Ligamentos Colaterais , Articulação do Cotovelo , Reconstrução do Ligamento Colateral Ulnar , Neuropatias Ulnares , Humanos , Masculino , Adulto Jovem , Adulto , Feminino , Reconstrução do Ligamento Colateral Ulnar/métodos , Cotovelo/cirurgia , Ligamento Colateral Ulnar/cirurgia , Ligamento Colateral Ulnar/lesões , Nervo Ulnar/cirurgia , Neuropatias Ulnares/etiologia , Articulação do Cotovelo/cirurgia , Ligamentos Colaterais/cirurgia , Ligamentos Colaterais/lesões , Beisebol/lesões
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...