Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 832
Filtrar
1.
J. optom. (Internet) ; 17(3): [100506], jul.-sept2024. ilus, tab, graf
Artigo em Inglês | IBECS | ID: ibc-231870

RESUMO

Purpose: To investigate the visual function correlates of self-reported vision-related night driving difficulties among drivers. Methods: One hundred and seven drivers (age: 46.06 ± 8.24, visual acuity [VA] of 0.2logMAR or better) were included in the study. A standard vision and night driving questionnaire (VND-Q) was administered. VA and contrast sensitivity were measured under photopic and mesopic conditions. Mesopic VA was remeasured after introducing a peripheral glare source into the participants' field of view to enable computation of disability glare index. Regression analyses were used to assess the associations between VND-Q scores, and visual function measures. Results: The mean VND-Q score was -3.96±1.95 logit (interval scale score: 2.46±1.28). Simple linear regression models for photopic contrast sensitivity, mesopic VA, mesopic contrast sensitivity, and disability index significantly predicted VND-Q score (P<0.05), with mesopic VA and disability glare index accounting for the greatest variation (21 %) in VND-Q scores followed by photopic contrast sensitivity (19 %), and mesopic contrast sensitivity (15 %). A multiple regression model to determine the association between the predictors (photopic contrast sensitivity, mesopic VA, mesopic contrast sensitivity, and disability index) and VND-Q score yielded significant results, F (4, 102) = 8.58, P < 0.001, adj. R2 = 0.2224. Seeing dark-colored cars was the most challenging vision task. Conclusion: Changes in mesopic visual acuity, photopic and mesopic contrast sensitivity, as well as disability glare index are associated with and explain night driving-related visual difficulties. It is recommended to incorporate measurement of these visual functions into assessments related to driving performance.(AU)


Assuntos
Humanos , Masculino , Feminino , Condução de Veículo , Visão Noturna , Acidentes de Trânsito , Visão de Cores , Visão Mesópica , Ofuscação/efeitos adversos
2.
Arq Bras Oftalmol ; 87(3): e20230257, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38716966

RESUMO

PURPOSE: This review emphasizes the effect of light on visual efficiency, the impact of different lighting focuses, types of lighting, and their influence on vision and productivity. Light sources and standards are intriguing subjects for ophthalmologists. Guidelines regarding the level of lighting influence on visual activities can enhance visual performance.Methods: This article was developed based on literature reviews, with a bibliographic survey conducted in databases such as PubMed, MEDLINE, Web of Science, Embase, LILACS, and SciELO. RESULTS: Provides recommendations for understanding information regarding the influence of lighting on visual performance. CONCLUSION: Proper workplace lighting is crucial for improving visual efficiency, safety, productivity, and worker health. Efficient workplace lighting should avoid light sources directed towards the worker's face, prevent harmful glare, be more intense in the work area, and uniform in the rest of the room. Ophthalmologists should be knowledgeable about and provide guidance on correct lighting to ensure patient comfort and satisfaction with visual correction.


Assuntos
Iluminação , Humanos , Visão Ocular/fisiologia , Acuidade Visual/fisiologia , Local de Trabalho , Saúde Ocupacional , Ofuscação , Luz
3.
J Cataract Refract Surg ; 50(6): 565-571, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38350161

RESUMO

PURPOSE: To explore the influence of preoperative factors, including varying pupil sizes and refractive attributes, on postoperative glare disability in patients undergoing implantable collamer lens (ICL) implantation. SETTING: Second Affiliated Hospital, Nanchang University, Nanchang, Jiangxi, China. DESIGN: Prospective observational study. METHODS: The preoperative ocular characteristics and 6-month postoperative glare status in eligible patients who underwent EVO-Visian ICL V4c (VICMO) implantation were analyzed. The glare disability criteria encompassed a glare symptom score >6 and glare sensitivity exceeding 1:2.7. Logistic regression analysis was used to explore the relationship between the preoperative ocular parameters and post-ICL glare. RESULTS: The study included 95 patients (mean age, 26.04 ± 6.29 years), comprising 30 men (58 eyes) and 65 women (129 eyes). Multivariate analysis revealed a significant correlation between postoperative glare disability and increased spherical power in preoperative mesopic pupils (ß = -0.124, P = .039), as well as elevated cylinder power in preoperative mesopic (ß = -0.412, P = .009) and photopic pupils (ß = -0.430, P = .007). Moreover, a larger preoperative mesopic pupil diameter (ß = 0.561, P = .005) demonstrated a significant correlation with glare disability. CONCLUSIONS: Preoperative mesopic pupil dimensions and associated refractive parameters, such as sphere and cylinder, were correlated with glare disability, including the cylinder aspect in photopic pupils, which can assist clinicians in optimizing preoperative selection for ICL implantation, aiding in the anticipation of potential glare disability risks.


Assuntos
Ofuscação , Implante de Lente Intraocular , Visão Mesópica , Lentes Intraoculares Fácicas , Pupila , Acuidade Visual , Humanos , Estudos Prospectivos , Adulto , Feminino , Fatores de Risco , Masculino , Visão Mesópica/fisiologia , Adulto Jovem , Pupila/fisiologia , Acuidade Visual/fisiologia , Pessoa de Meia-Idade , Adolescente , Transtornos da Visão/fisiopatologia , Miopia/cirurgia , Miopia/fisiopatologia , Refração Ocular/fisiologia
4.
J Cataract Refract Surg ; 50(6): 631-636, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38407983

RESUMO

PURPOSE: To compare precision of pupil size measurements of a multifunctional device (Pentacam AXL Wave [Pentacam]) and 2 infrared-based pupillometers (PupilX, Colvard) and to compare repeatability of Pentacam and PupilX. SETTING: Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany. DESIGN: Prospective, comparative trial. METHODS: Pupil diameter of healthy eyes was measured with Colvard once and Pentacam without glare (WO) and with glare (WG), PupilX in 0, 1, and 16 lux 3 times each. In a second series, measurements with Pentacam WO and PupilX in 0.06 and 0.12 lux were assessed. RESULTS: 36 eyes of participants aged 21 to 63 years were included. Mean pupil diameter was 6.05 mm with Colvard, 5.79 mm (first series), 5.50 mm (second series) with Pentacam WO, 3.42 mm WG, 7.26 mm PupilX in 0, 4.67 mm 1, 3.66 mm 16, 6.82 mm in 0.06, and 6.39 mm in 0.12 lux. Measurements with Pentacam WO were significantly different to PupilX in 0, 0.06, 0.12, and 1 lux (all P < .001), but not to Colvard ( P = .086). Pupil size measured with Pentacam WG and PupilX in 16 lux was not significantly different ( P = .647). Consecutive measurements with Pentacam WO and WG had mean SD of 0.23 mm and 0.20 mm, respectively, and with PupilX 0.11 in 0, 0.24 mm 1, and 0.20 mm in 16 lux. CONCLUSIONS: Pentacam provided good assessment of pupil size but was not equivalent to PupilX in low lighting conditions. Repeatability was more favorable for Pentacam.


Assuntos
Interferometria , Pupila , Humanos , Pupila/fisiologia , Estudos Prospectivos , Adulto , Pessoa de Meia-Idade , Masculino , Feminino , Adulto Jovem , Reprodutibilidade dos Testes , Interferometria/instrumentação , Aberrometria/instrumentação , Iris , Raios Infravermelhos , Técnicas de Diagnóstico Oftalmológico/instrumentação , Ofuscação
5.
J Cataract Refract Surg ; 50(4): 413-419, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38237073

RESUMO

PURPOSE: To objectively quantify glare of intraocular lenses (IOLs) using a diffractive principle to extend the visual range and to identify models with increased susceptibility to inducing glare. SETTING: David J Apple Laboratory, Heidelberg, Germany. DESIGN: Laboratory investigation. METHODS: Glare was assessed by means of a straylight parameter with a standard C-Quant intended for 7 degrees. In addition, 2 C-Quant modifications were used to test lower angles (ie, 2.5 degrees and 3.5 degrees). The following IOL models were assessed: PanOptix, AT Lisa Tri, Synergy, and Triumf, the latter 2 with chromatic aberration correction at distance. Straylight from trifocal IOLs was compared against a monofocal W-60R lens. The C-Quant test was performed through the studied IOLs by using additional optical components attached to their ocular. RESULTS: Straylight (deg 2 sr -1 ) of the control was <1 at all tested angles, with the trifocal models showing comparable straylight at 7 degrees. At 3.5 degrees, Triumf's straylight increased to 15.5 ± 0.6, followed by Synergy (6.2 ± 1.1), PanOptix (4.1 ± 0.3), and AT Lisa Tri (2.0 ± 0.8). The chromatic aberration-correcting models demonstrated correspondingly higher straylight (Synergy: 18.8 ± 1.3; Triumf: 17.3 ± 0.5) at 2.5 degrees compared with PanOptix (4.3 ± 0.4), AT Lisa Tri (2.1 ± 0.1), and monofocal IOLs yielding minimal or no increase. CONCLUSIONS: Trifocal IOLs induced increased straylight, but it was limited to lower angles, which may cause difficulties detecting these effects using a standard clinical approach. The latest IOL designs featuring chromatic aberration correction at far focus seem more susceptible than the established trifocal IOLs to inducing a glare phenomenon.


Assuntos
Cristalino , Lentes Intraoculares , Presbiopia , Humanos , Ofuscação , Presbiopia/cirurgia , Óculos , Desenho de Prótese
6.
Sci Rep ; 13(1): 18551, 2023 10 29.
Artigo em Inglês | MEDLINE | ID: mdl-37899478

RESUMO

Understanding the factors that influence the human perception of glare is necessary to properly address glare risks in buildings and achieve comfortable visual environments, especially in the workplace. Yet large inter-individual variabilities in glare perception remain unexplained and thus uncovered by the current empirical glare models. We hypothesize that this variability has an origin in the human retina, in particular in the density of macular pigments present in its central area, which varies between individuals. Macular pigments are known to absorb blue light and attenuate chromatic aberration, thus reducing light scatter. This study presents the outcomes of the first experiment ever conducted in a daylit office environment, in which glare sensitivity and macular pigment density were measured and compared for 110 young healthy individuals, along with other ocular parameters. The participants were exposed to different glare conditions induced by the sun filtered through either color-neutral or blue-colored glazing. In neutral daylight conditions with sun disc in the near periphery, neither macular pigment nor any other investigated ocular factors have an impact on discomfort glare perception whereas glare perception in conditions with the blue-colored sun disc in the near periphery was found to be correlated with macular pigment optical density.


Assuntos
Macula Lutea , Pigmento Macular , Humanos , Ofuscação , Pigmentos da Retina , Luz , Sensibilidades de Contraste
7.
BMJ Open Ophthalmol ; 8(1)2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37493673

RESUMO

OBJECTIVE: To compare subjective levels of comfort and visual experiences related to microscope light in patients undergoing their first cataract surgery with topical anaesthesia using a digital microscope (the NGENUITY three-dimensional (3D) visualisation system) or a conventional microscope. METHODS AND ANALYSIS: A prospective, randomised, single-blinded, parallel-group, multicentre, interventional study. Patients (n=128) were randomly assigned to one of two treatment groups: the experimental group (n=63) had surgery using the digital microscope and the control group (n=65) had surgery with a conventional microscope. The primary outcome was patients' subjective experience of glare from the microscope light during surgery on a numerical scale from 0 to 10. Key secondary outcomes were patients' subjective levels of comfort and visual experiences related to the microscope light. RESULTS: The experimental group reported significantly lower levels of glare; median levels were 1.0 (0.0-4.0) for the experimental group vs 3.0 (0.0-6.0) for the control group (p=0.027). They also reported higher levels of comfort; median ratings were 8.0 (6.5-10.0) in the experimental group and 7.0 (5.0-9.0) in controls (p=0.026). There were no group differences in ratings of subjective pain or visual disturbances. Median microscope light intensity was lower in the experimental group than controls; 3425.0 (2296.0-4300.0) Lux vs 24 279.0 (16 000.0-26 500.0) Lux (p<0.0001), respectively. CONCLUSION: Compared with conventional microscopes, the NGENUITY 3D visualisation system allows surgeons to operate with lower levels of light exposure, resulting in significantly less glare and improved comfort in patients undergoing cataract surgery. TRIAL REGISTRATION NUMBER: NCT05085314.


Assuntos
Extração de Catarata , Catarata , Humanos , Estudos Prospectivos , Ofuscação , Método Simples-Cego
8.
J Refract Surg ; 39(6): 398-404, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37306204

RESUMO

PURPOSE: To investigate influencing factors of glare in patients with myopia after small incision lenticule extraction (SMILE). METHODS: Thirty patients (60 eyes) aged 24.9 ± 4.5 years with spherical equivalent of -6.69 ± 1.10 diopters (D) and astigmatism of -1.25 ± 0.76 D who underwent SMILE were consecutively recruited in this prospective study. Visual acuity, subjective refraction, Pentacam corneal topography (Oculus Optikgeräte GmbH), pupillometry, and glare test (Monpack One; Metrovision) were measured preoperatively and postoperatively. All patients were followed up for 6 months. The generalized estimation equation was used to judge the determinants of glare after SMILE, and a P value less than .05 was statistically significant. RESULTS: Under mesopic conditions, the halo radii preoperatively and at 1, 3, and 6 months after SMILE were 207.72 ± 46.67, 216.17 ± 40.63, 200.67 ± 34.68, and 193.50 ± 40.75 minutes of arc (arcmin), respectively. Under photopic conditions, the glare radii were 79.10 ± 17.78, 87.00 ± 20.44, 78.00 ± 14.59, and 72.00 ± 15.27 arcmin, respectively. Compared with preoperative glare, no significant changes were detected in postoperative glare. However, glare at 6 months was statistically significantly improved compared to the values at 1 month (both P < .05). Under mesopic conditions, the main influencing factors of glare were sphere (P = .007), astigmatism (P = .032), uncorrected distance visual acuity (UDVA) (P < .001), and postoperative time (all P < .05). Under photopic conditions, the main influencing factors of glare were astigmatism, UDVA, and postoperative time (all P < .05). CONCLUSIONS: Glare improved with time during the early stages after SMILE for myopia. Less glare was found to be associated with better UDVA, and greater residual astigmatism and sphere translated to more obvious glare. [J Refract Surg. 2023;39(6):398-404.].


Assuntos
Astigmatismo , Miopia , Ferida Cirúrgica , Humanos , Astigmatismo/etiologia , Astigmatismo/cirurgia , Ofuscação , Estudos Prospectivos , Miopia/cirurgia , Refração Ocular
9.
Int Ophthalmol ; 43(9): 3309-3319, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37329407

RESUMO

PURPOSE: Glare visual acuity and contrast sensitivity are important indicators of visual quality. Studies have shown that the glare visual acuity and contrast sensitivity in dry eye patients tend to degenerate, further affecting their quality of life. The objective of this study was to investigate the effect of notch filters on glare VA and contrast sensitivity in patients with dry eye or with dry eye syndrome. METHOD: 36 subjects in the 20‒65 age group were diagnosed as having dry eye disease or perceived dry eye syndromes themselves who were included after the initial screening with the OSDI questionnaire, and one was subsequently excluded as they had undergone retinal detachment surgery. Finally, 35 subjects (14 male and 21 female) with a mean age of 40.66 ± 15.62 years participated in this study. All subjects wore their habitual prescriptions and four different filter lenses (namely 480, 620, dual 480 & 620 notch filter, and FL-41 tinted lens), and measured the parameters of glare visual acuity and contrast sensitivity using CSV-1000 and sine wave contrast test (SWCT), respectively. Student t-test and Repeated measurement analysis (R-ANOVA) were utilized by using SPSS 26.0 software. RESULTS: A dual-wavelength 480 & 620 nm optical notch filter had a significant anti-glare effect decreasing glare disabilities or discomfort, and leading to better visual quality, the same effect was also shown on a 480 nm notch filter lens. All participants showed a significant difference among the baseline, three notch filters (480 nm, 620 nm, dual-wavelength 480 & 620 nm), and FL-41 tinted lens were used on SWCT_A (1.5 cpd, F = 3.054, p = 0.019) and SWCT_E (18 cpd, F = 2.840, p = 0.049); but did not show statistical different on SWCT_B (3 cpd, F = 0.333, p = 0.771), SWCT_C (6 cpd, F = 1.779, p = 0.159), and SWCT_D (12 cpd, F = 1.447, p = 0.228). The baseline showed the best visual performance on CS at a low spatial frequency (SWCT_A, 1.5 cpd), any filter might reduce the contrast sensitivity at low spatial frequencies in the clinical trial, whereas 480 nm notch filter showed the best effectiveness on CS at a high spatial frequency (SWCT_E, 18 cpd), the FL-41 lens that also filters out the 480 nm band does not achieve the same effect. Moreover, patients with dry eye or those older than 40 years old preferred optical multilayer notch filters to FL-41 tinted lenses. CONCLUSION: The 480- & 620-nm dual-wavelength and 480-nm single-wavelength notch filters have the best effect on the glare visual acuity and contrast sensitivity (CS) at high spatial frequencies in dry eye patients. The 620-nm notch filter performs better in CS at low and mid-low spatial frequencies; the FL-41 tinted lens performs poorly for glare VA and CS spatial frequencies examination. Patients with glare disabilities or CS disturbance at high spatial frequencies may choose a 480-nm notch filter lens, and patients who have CS disturbance at low spatial frequencies may consider a 620-nm notch filter for the prescription.


Assuntos
Sensibilidades de Contraste , Síndromes do Olho Seco , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Qualidade de Vida , Acuidade Visual , Ofuscação , Síndromes do Olho Seco/diagnóstico
10.
Nature ; 618(7966): 651, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37311998
11.
BMC Ophthalmol ; 23(1): 223, 2023 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-37208645

RESUMO

BACKGROUND: To investigate the dynamic changes and influencing factors of visual symptoms after small incision lenticule extraction (SMILE). METHODS: This was a prospective observational study. Visual symptoms including glare, haloes, starbursts, hazy vision, fluctuation, blurred vision, double vision and focusing difficulties were evaluated before and 1, 3, 6 months after SMILE using a questionnaire. Generalized linear mixed models were used to assess the effects of preoperative characteristics and objective visual quality parameters on postoperative visual symptoms. RESULTS: 73 patients/146 eyes were enrolled. Preoperatively, the most common symptoms were glare (55% of eyes), haloes (48%), starbursts (44%) and blurred vision (37%). At 1 month postoperatively, the incidence and extent scores of glare, haloes, hazy vision and fluctuation rose significantly. At 3 months, the incidence and extent scores of glare, haloes and hazy vision restored to baseline. And at 6 months, the extent scores of fluctuation returned to baseline. Other symptoms (e.g., starbursts) did not change before and 1, 3, 6 months after SMILE. Preoperative visual symptoms were associated with postoperative symptoms, as patients with a symptom preoperatively had higher postoperative scores for that symptom. Age was related to postoperative extent of double vision (coefficient = 0.12, P = 0.046). There were no significant associations between postoperative visual symptoms and preoperative SE, scotopic pupil size, angle kappa (with intraoperative adjustment), postoperative HOAs or scattering indexes. CONCLUSIONS: The incidence and extent scores of hazy vision, glare, haloes and fluctuation increased at the first month after SMILE, and recovered to baseline at 3 or 6 months. Preoperative visual symptoms were associated with the postoperative symptoms and should be fully considered before SMILE.


Assuntos
Cirurgia da Córnea a Laser , Miopia , Humanos , Acuidade Visual , Substância Própria/cirurgia , Miopia/cirurgia , Miopia/diagnóstico , Cirurgia da Córnea a Laser/efeitos adversos , Ofuscação , Transtornos da Visão/etiologia , Diplopia/cirurgia , Lasers de Excimer/uso terapêutico , Refração Ocular
12.
Curr Eye Res ; 48(7): 639-644, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37074213

RESUMO

PURPOSE: One common complaint with natural opacified lenses is the deleterious effects of higher-order ocular aberrations and intraocular scatter, such as halos and starbursts, which are not always remedied with surgery and intraocular lens (IOL) implantation. Blue-light filtering (BLF) IOL filter scatter-prone short-wave light. Here, we determine whether BLF IOL reduce halo and starburst size. METHODS: This study was a case-control design, between- and within-subjects (contralateral implantation). Sixty-nine participants with either the BLF IOL (n = 25; AlconSN60AT), clear IOL (n = 24; AlconSA60AT or WF), or both (n = 20) IOL participated. Participants were exposed to a point source of broadband simulated sunlight, which created the appearance of halos/starbursts. Dysphotopsia was measured as the diameter of broadband light-induced halos and starbursts. RESULTS: A case-control analysis. Halo size was significantly larger (t[35.05] = 2.98, p = 0.005) in participants with the clear control lens (M = 3°55' ± 2°48'), compared to the BLF IOL (M = 1°84' ± 1°34'). Starburst size was not significantly different between groups. Contralateral analysis. Halo size was significantly smaller (t = -3.89, p = .001) in test eyes with the BLF (M = 3°16' ± 2°35') compared to the fellow control eyes (M = 5°42' ± 3°17'). Starburst size was also significantly smaller (t = -2.60, p < 0.018) in BLF test eyes (M = 9°57' ± 4°25') than the fellow eye with the clear IOL (M = 12°33' ± 5°25'). CONCLUSIONS: BLF IOL filter short-wave light and mimic retinal screening by the young, natural crystalline lens. Such filtering can reduce some deleterious effects of bright light by decreasing ocular diffusion/halos and starbursts.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Ofuscação , Implante de Lente Intraocular , Sensibilidades de Contraste , Luz , Desenho de Prótese
13.
Sci Rep ; 13(1): 3508, 2023 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-36864120

RESUMO

The full assessment of the visual system must include the evaluation of the optical quality of the eye and neural visual functions. The objective evaluation of the retinal image quality is often carried out by computing the point spread function (PSF) of the eye. The central part of the PSF is associated with optical aberrations and the peripheral areas with scattering contributions. In that sense, visual acuity and contrast sensitivity function tests can be considered the perceptual neural response to those contributions characterizing the eye's PSF. However, in natural viewing conditions, visual acuity tests may provide good vision while contrast sensitivity tests can reveal visual impairment in glare vision conditions, such as exposure to bright light sources or night driving conditions. Here we present an optical instrument for the study of disability glare vision under extended Maxwellian illumination to assess the contrast sensitivity function under glare conditions. The limit of the Total Disability Glare threshold, tolerance, and glare adaptation will be investigated as a function of the angular size of the glare source (GA) and the contrast sensitivity function in young adult subjects.


Assuntos
Ofuscação , Baixa Visão , Humanos , Adulto Jovem , Testes Visuais , Acuidade Visual , Aclimatação
14.
Invest Ophthalmol Vis Sci ; 64(1): 6, 2023 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-36626175

RESUMO

Purpose: To investigate changes in shape discrimination under mesopic conditions with and without glare after orthokeratology in myopic children. Methods: This prospective study included 79 eyes of 79 myopic children (ages: 8-16 years). Shape discrimination thresholds (SDTs) were measured using radial frequency patterns, with a radial frequency of 4 cycles/360°, a peak spatial frequency of 3 cycles per degree, a contrast of 20%, and a mean radius of 1.5 degrees. SDT under mesopic conditions with and without glare was measured before orthokeratology and again at 1 week and 1 month after orthokeratology. Changes in the SDTs and their relationships to baseline ocular parameters were analyzed. Results: SDTs with glare decreased significantly at 1 week (-0.08 ± 0.15 log(arcsec), P < 0.001) and 1 month (-0.09 ± 0.15 log(arcsec), P < 0.001) after orthokeratology. SDTs without glare remained stable (P = 0.81 and P = 1.00, respectively). The difference between SDTs with and without glare also decreased significantly at 1 week (-0.10 ± 0.17 log(arcsec), P < 0.001) and at 1 month (-0.08 ± 0.18 log(arcsec), P = 0.001) after orthokeratology. Based on a multivariate analysis, the greater decrease in SDT with glare after 1 month of orthokeratology was associated with a higher baseline spherical equivalent refraction. Conclusions: Orthokeratology resulted in improved shape discrimination in myopic children under mesopic conditions but only when measured in the presence of glare.


Assuntos
Miopia , Procedimentos Ortoceratológicos , Humanos , Criança , Adolescente , Acuidade Visual , Estudos Prospectivos , Ofuscação , Sensibilidades de Contraste , Miopia/terapia , Refração Ocular , Córnea
15.
Eur J Neurosci ; 57(2): 388-399, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36484768

RESUMO

Individuals diagnosed with schizophrenia spectrum disorders (SSD) exhibit a constellation of sensory and perceptual impairments, including hyporeactivity to external input. However, individuals with SSD also report subjective experiences of sensory flooding, suggesting sensory hyperexcitability. To identify the extent to which behavioural indices of hyperexcitability are related to non-psychotic symptoms of schizophrenia, we tested a non-clinical population measured for schizophrenia-like traits (schizotypy), and a behavioural measure of sensory hyperexcitability, specifically the number of illusions seen in the Pattern Glare Test. Two samples totaling 913 individuals completed an online version of the Schizotypal Personality Questionnaire - Brief Revised (SPQ-BR) and the Pattern Glare Test. Individuals with higher schizotypy traits reported more illusions in the Pattern Glare Test. Additionally, one of the three SPQ-BR factors, the disorganized factor, significantly predicted the number of illusions reported. These data illustrate the potential for research in non-clinical samples to inform clinically relevant research.


Assuntos
Ilusões , Esquizofrenia , Transtorno da Personalidade Esquizotípica , Humanos , Transtorno da Personalidade Esquizotípica/diagnóstico , Ofuscação , Ansiedade , Inquéritos e Questionários
16.
Invest Ophthalmol Vis Sci ; 63(12): 17, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36374515

RESUMO

Purpose: We investigated decline in the visual function of eyes with retrodots (RDs)-a subtype of cataract. Method: This study included 57 eyes with RD opacity only (mean age 72.3 ± 5.2 years) and 34 eyes with transparent lenses (mean age 71.4 ± 3.7 years). A physician diagnosed lens opacity. Using the Kanazawa Medical University Classification and Grading System, the eyes were classified into the RD-1 (37 eyes, RDs <25% of the 3-mm pupil area) and RD-2 (20 eyes, RDs ≥25% of the 3-mm pupil area) groups. Corrected distance visual acuity, contrast visual acuity, ocular refractive power, lens power, straylight, and backward light-scattering intensity and their relationship with visual function decline and optical characteristics of the eyeball were evaluated. Results: Corrected distance visual acuity was significantly lower in the RD eyes than in controls. Contrast visual acuity decreased significantly in the RD-2 eyes in all environments and in the RD-1 eyes in the evening (EVE) and EVE + glare. Straylight was significantly higher in the RD-2 eyes than in the controls and RD-1 eyes but not different between the RD-1 eyes and controls. The RD-2 eyes were significantly more myopic than the controls and RD-1 eyes. Conclusion: When the opacity of RD eyes is ≥25%, the visual acuity and contrast visual acuity decrease and straylight increases. Furthermore, myopia occurs as the refractive power of the lens increases. Moreover, visual function decline may be due to an increase in the straylight value, which is necessary for determining surgical indications.


Assuntos
Catarata , Miopia , Humanos , Idoso , Espalhamento de Radiação , Ofuscação , Acuidade Visual , Pupila
17.
Opt Express ; 30(15): 27140-27148, 2022 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-36236891

RESUMO

Light emitting diodes (LEDs) have become a major source of lighting conditions. The increased prevalence of LED light sources introduces new concerns for the spectral effects of positive dysphotopsia (PD) or glare type photic phenomena for pseudo-phakic patients with intraocular lenses (IOLs). A significant amount of work has been published in the area of spectral discomfort and sensitivity of LEDs as well as automotive lighting. The wavelength dependence or spectral properties of PD due to LEDs for IOLs has not been reported. This study, to our knowledge, is the first one to assess the glare characteristics of four commercially available IOL models with different material types and design features using an optical bench and non-sequential ray trace simulations with LEDs of different wavelengths. A novel approach of representing the reflected and transmitted IOL glare utilizing Fresnel coefficients is found to be in close agreement with the measurements.


Assuntos
Ofuscação , Lentes Intraoculares , Humanos , Lentes Intraoculares/efeitos adversos , Desenho de Prótese , Transtornos da Visão/diagnóstico , Transtornos da Visão/etiologia
18.
Eye Contact Lens ; 48(12): 509-515, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36201639

RESUMO

OBJECTIVES: We assessed the effects of a HEV-filtering contact lens on positive dysphotopsia (halos and starbursts) and a behavioral index of scatter measured using two-point light thresholds. These effects were assessed by direct comparison to a clear (i.e., non-HEV filtering) contact lens tested in the fellow eye. METHODS: Sixty-one subjects were randomized and fit with study lenses and 58 subjects completed the study. A double-masked contralateral design was used. Subjects were randomized to test lens-OD, control lens-OS, or vice versa. Participants were exposed to a point source of broadband simulated sunlight (a 403-nm condition was also tested) that created the appearance of halos/starbursts. The degree of dysphotopsia was measured as the diameter of broadband and violet-induced halos, and broadband light-induced starbursts. Two-point thresholds were assessed as the minimum resolvable distance between two pinpoints of light. RESULTS: The HEV-filtering lens was statistically superior ( P <0.0001) to the clear lens in all the conditions tested. The HEV-filtering lens significantly reduced halo diameter by 30%, starburst diameter by 23%, and resolvable distance in the two-point condition by 18% (white) and 30% (violet). CONCLUSIONS: HEV-filtering contact lenses can reduce some deleterious effects of bright broadband light by decreasing light scatter, halos, and starbursts.


Assuntos
Lentes de Contato , Ofuscação , Humanos , Transtornos da Visão
19.
BMC Ophthalmol ; 22(1): 402, 2022 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-36209072

RESUMO

PURPOSE: Dim light vision disturbances (DLD) comprise a wide range of symptoms affecting the quality of vision at low illumination including glare, halos, and starbursts. This exploratory study investigated 1.0% phentolamine mesylate ophthalmic solution (PMOS) as a treatment to improve vision and image quality for patients with DLD. METHODS: In this placebo-controlled, randomized, double-masked clinical trial, 24 adult patients with severe DLD were randomized in a 2:1 ratio to receive either one dose of PMOS or placebo. Subjects were eligible if they reported experiencing severe night vision difficulty that was not eliminated by distance spectacle correction and scored ≥0.3 log units below the normal range of contrast sensitivity assessed under mesopic conditions with glare at ≥2 spatial frequencies. Key efficacy outcomes were change from baseline in pupil diameter, contrast sensitivity, and visual acuity. Safety measures including intraocular pressure, conjunctival hyperemia, and systemic effects were also assessed. RESULTS: Eight subjects were randomized to placebo (63% female; mean age 47 years) and 16 were randomized to PMOS (75% female; mean age 42 years). Mean (SD) pupil diameter of PMOS-treated subjects decreased significantly - 1.3 mm (0 to - 2.8 mm) with p < 0.0001. Mean contrast sensitivity with glare in PMOS-treated subjects improved significantly post-treatment at spatial frequencies 3, 6, 12, and 18 cycles per degree (p ≤ 0.03). PMOS also demonstrated improvements in the numbers of letters read for mesopic and photopic, high- and low-contrast visual acuity (LCVA). Importantly, a statistically greater proportion of PMOS-treated eyes registered mesopic LCVA 5 letter (69% vs. 31%, p = 0.029) and 10 letter (34% vs. 6%, p = 0.04) improvement, with a trend at 15 letters (19% vs. 0%, p = 0.16). PMOS was well tolerated with the only reported side effect being a mild increase in conjunctival hyperemia. CONCLUSION: PMOS was well tolerated and effectively reduced pupil size with improvements in contrast sensitivity and visual acuity in adults with severe DLD. Future Phase 3 studies should be conducted to further evaluate its potential to treat DLD. TRIAL REGISTRATION: The trial registration number is NCT04004507 (02/07/2019). Retrospectively registered.


Assuntos
Hiperemia , Cegueira Noturna , Adulto , Sensibilidades de Contraste , Feminino , Ofuscação , Humanos , Masculino , Pessoa de Meia-Idade , Visão Noturna , Soluções Oftálmicas , Fentolamina/uso terapêutico , Transtornos da Visão/tratamento farmacológico
20.
Eye Contact Lens ; 48(12): 516-520, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36083159

RESUMO

OBJECTIVES: Glare discomfort (GDC) is the slight pain (discomfort) that arises when exposed to light that exceeds one's adaptive state. Such light can also cause a temporary loss in visual function (photostress, PS). We tested the hypothesis that filtering with a high-energy visible (HEV) light-filtering contact lens can reduce GDC and speed PS recovery time. METHODS: Sixty-one subjects were randomized and fit with study lenses and 58 subjects completed as cohort (20-65 years of age). A double-masked, randomized, contralateral design was used (HEV filter on one eye; control lens on the other). Participants were given a 5-s exposure to a broadband white photostressor. Video images were analyzed, and palpebral fissure size during exposure was measured, as was PS recovery time to a 2-degree mid-wave target. RESULTS: The HEV-filtering test lens was statistically superior ( P <0.0001) to the clear comparison contact lens with respect to the magnitude of squint (44.9% squint reduction) and photostress recovery time (24.3% faster recovery). CONCLUSIONS: High-energy visible light-filtering contacts can reduce GDC and speed PS recovery. Filtering HEV light before it is incident upon the retina is a natural strategy (e.g., by the lens and macular pigment) for attenuating some of the deleterious effects of bright broadband light.


Assuntos
Lentes de Contato , Estrabismo , Humanos , Ofuscação , Sensibilidades de Contraste , Luz
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...