RESUMO
Drug transporters and CYP enzymes are important sources of pharmacokinetics (PK) variability in drug responses and can cause various pharmacological and toxicological consequences, leading to either toxicity or an insufficient pharmacological effect. In recent years, the cocktail approach was developed to determine in vivo CYP and transporters activities, but these approaches are somewhat limited. We described the development and validation of three sensitive and specific LC-MS/MS assays for the determination of P-gp and major human CYP isoenzyme activities following oral administration of a drug cocktail of subtherapeutic doses (lower than 10 times) of caffeine (CAF), omeprazole (OME), losartan (LOS), midazolam (MDZ), metoprolol (METO) and fexofenadine (FEX) in healthy volunteers. The three validated methods were selective for all tested analytes. No interference or matrix effect was observed for the mass transition and retention times for all compounds monitored. Additionally, assays were linear over a wide range, and limits of quantification varied between 0.01-5 ng/mL plasma. The coefficients of variation obtained in the precision studies and the inter- and intra-assay accuracies were less than 15%, guaranteeing the reproducibility and repeatability of the results. All substrates and metabolites were stable in plasma during freeze-thaw cycles. Three healthy volunteers were selected based on genotyping for CYP2C9, CYP2C19 and CYP2D6. One volunteer was genotyped as an extensive metabolizer (EM) for all tested CYP isoforms, one volunteer was genotyped as a poor metabolizer (PM) for the CYP2C9 isoform (CYP2C9*3/*3), and one volunteer was genotyped as a PM for the CYP2D6 isoform (CYP2D6*4/*4). The methods allowed the quantification of all analytes over the entire sampling period (12 h) in all studied genotypes. Thus, the analytical methods described here were sufficiently sensitive for use in low-dose pharmacokinetic studies.
Assuntos
Citocromo P-450 CYP2C19/metabolismo , Citocromo P-450 CYP2C9/metabolismo , Citocromo P-450 CYP2D6/metabolismo , Subfamília B de Transportador de Cassetes de Ligação de ATP/metabolismo , Adulto , Variação Biológica da População/genética , Cafeína/administração & dosagem , Cafeína/análise , Cafeína/farmacocinética , Cromatografia Líquida de Alta Pressão/instrumentação , Cromatografia Líquida de Alta Pressão/métodos , Citocromo P-450 CYP2C19/genética , Citocromo P-450 CYP2C9/genética , Citocromo P-450 CYP2D6/genética , Voluntários Saudáveis , Humanos , Isoenzimas/genética , Isoenzimas/metabolismo , Losartan/administração & dosagem , Losartan/análise , Losartan/farmacocinética , Masculino , Metoprolol/administração & dosagem , Metoprolol/análise , Metoprolol/farmacocinética , Midazolam/administração & dosagem , Midazolam/análise , Midazolam/farmacocinética , Omeprazol/administração & dosagem , Omeprazol/análise , Omeprazol/farmacocinética , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/instrumentação , Espectrometria de Massas em Tandem/métodos , Terfenadina/administração & dosagem , Terfenadina/análogos & derivados , Terfenadina/análise , Terfenadina/farmacocinéticaRESUMO
The electrochemical incineration of omeprazole, a widely prescribed gastrointestinal drug which is detected in natural waters, has been studied in a phosphate buffer of pH 7.0 by anodic oxidation with electrogenerated H(2)O(2) (AO-H(2)O(2)) operating at constant current density (j). The experiments were carried out in a cell equipped with either a Pt or a boron-doped diamond (BDD) anode and an air-diffusion cathode to continuously produce H(2)O(2). In these systems, organics are mainly oxidized by hydroxyl radicals formed at the Pt or BDD surface from water oxidation. A partial total organic carbon (TOC) abatement close to 78% for omeprazole was achieved by AO-H(2)O(2) with a BDD anode after consumption of 18 Ah L(-1) at 100 mA cm(-2), whereas the alternative use of Pt did not allow mineralizing the drug. However, the drug was totally removed using both anodes, although it decayed more rapidly using BDD. In this latter system, increasing j accelerated the degradation process, but lowering the mineralization current efficiency. Greater drug content also enhanced the degradation rate with higher mineralization degree and current efficiency. The kinetics for omeprazole decay always followed a pseudo-first-order reaction and its rate constant increased with increasing j and with decreasing its concentration. Seven heteroaromatic intermediates and four hydroxylated derivatives were detected by LC-MS, while nine short-linear carboxylic acids were identified and quantified by ion-exclusion HPLC. These acids were largely accumulated using Pt and rapidly removed using BDD, thus explaining the partial mineralization of omeprazole achieved by AO-H(2)O(2) with the latter anode. The release of inorganic ions such as NO(3)(-), NH(4)(+) and SO(4)(2-) was followed by ionic chromatography. A plausible reaction sequence for omeprazole mineralization involving all intermediates detected is proposed.
Assuntos
Boro/química , Diamante/química , Eletroquímica/métodos , Incineração/métodos , Omeprazol/isolamento & purificação , Platina/química , Água/química , Ar , Carbono/análise , Ácidos Carboxílicos/análise , Difusão , Eletricidade , Eletrodos , Peróxido de Hidrogênio/química , Íons , Cinética , Minerais/química , Nitrogênio/análise , Omeprazol/análise , Omeprazol/química , Compostos Orgânicos/análise , Oxirredução , Soluções , Sulfatos/análise , Fatores de TempoRESUMO
A new spectrofluorimetric method for the determination of omeprazole (OMP) based on its degradation reaction catalyzed by ultraviolet (UV) light is proposed. OMP in aqueous solution is very unstable, which renders a serious difficulty for controlling its quality. It does not show native fluorescence, but when exposed to UV radiation, it generates a highly fluorescent degradation product with adequate stability for indirect OMP quantification. Under the studied optimal experimental conditions (pH, temperature, exposure time to UV radiation), a specific rate constant of 2.851 min⻹--described by zero-order kinetic--was obtained for the degradation reaction. Using λ(exc) 293 nm and λ(em) 317 nm, a linear relationship was obtained (r² 0.9998) in the concentration range of 0.1 to 1.3 µg mL⻹, with a detection limit of 1.07 10⻳ µg mL⻹ (S/N = 3). The methodology developed was successfully applied to OMP quality control in pure drugs and tablet dosage forms without previous treatment, with good tolerance to common excipient, and a high level of concordance between the nominal and experimental values. This work constitutes an important contribution to knowledge of the degradation mechanism of OMP. It has been shown to be appropriate for OMP quality control, to have an adequate sampling rate, low cost instrument, and to be a less polluting procedure.
Assuntos
Omeprazol/análise , Inibidores da Bomba de Prótons/análise , Espectrometria de Fluorescência , Calibragem , Estabilidade de Medicamentos , Concentração de Íons de Hidrogênio , Cinética , Modelos Moleculares , Estrutura Molecular , Omeprazol/química , Omeprazol/efeitos da radiação , Omeprazol/normas , Fotólise , Inibidores da Bomba de Prótons/química , Inibidores da Bomba de Prótons/efeitos da radiação , Inibidores da Bomba de Prótons/normas , Controle de Qualidade , Reprodutibilidade dos Testes , Espectrometria de Fluorescência/normas , Comprimidos , Temperatura , Raios UltravioletaRESUMO
Residual solvents in pharmaceutical samples are monitored using gas chromatography with head space. Based on good manufacturing practices, measuring residual solvents is mandatory for the release testing of all active pharmaceutical ingredients (API). The analysis of residual organic solvents (methanol, acetone, cyclohexane, dichloromethane, toluene) in Omeprazole, an active pharmaceutical ingredient was investigated. Omeprazole is a potent reversible inhibitor of the gastric proton pump H+/K+-ATPase. The Head space gas chromatography (HSGC) method described in this investigation utilized a SPB TM-624, Supelco, 30 m long x 0.25 mm internal diameter, 1.4µm-thick column. Since Omeprazole is a thermally labile compound, the selection of the proper injector temperature is critical to the success of the analysis. The injector temperature was set at 170ºC to prevent degradation. The initial oven temperature was set at 40ºC for 12 min and programmed at a rate of 10ºC min-1 to a final temperature of 220ºC for 5 min. Nitrogen was used as a carrier gas. The sample solvent selected was N,N-dimethylacetamide. The method was validated to be specific, linear, precise, sensitive, rugged and showed excellent recovery.
Solventes residuais em amostras farmacêuticas são monitoradas utilizando-se cromatografia a gás "headspace". Com base nas boas práticas de fabricação, a medida de solventes residuais é obrigatória para o teste de liberação de todos os ingredientes farmacêuticos (API). Efetuou-se a análise de solventes orgânicos residuais (metanol, acetona, cicloexano, diclorometano, tolueno) em omeprazol, ingrediente farmacêutico ativo. O omeprazol é potente inibidor reversível da bomba de prótons H+/K+-ATPase. A cromatografia a gás "headspace" (HSGC) descrita nessa pesquisa utilizou um SPB TM-624, Supelco, de 30 m de comprimento x 0,25 mm de diâmetro interno, e coluna de 1,4 µm de espessura. Considerando-se que o omeprazol é termicamente lábil, a seleção da temperatura apropriada do injetor é crítica para impedir a degradação. A temperatura inicial do forno foi de 40 ºC, por 12 minutos, e programada à taxa de acréscimo de 10 ºC min-1 até a temperatura final de 220 ºC, por 5 minutos. Nitrogênio foi utilizado como gás de transporte. Selecionou-se como solvente a N,N-dimetilacetamida. O método foi validado mostrando-se específico, linear, preciso, sensível, robusto e com excelente recuperação.
Assuntos
Cromatografia Gasosa , Omeprazol/análise , Omeprazol/química , Solventes/química , Inibidores Enzimáticos/análise , Inibidores Enzimáticos/química , Metodologia como AssuntoRESUMO
This work reports the use of a two-dimensional liquid chromatography (2D-LC) system for quantification of the enantiomers of omeprazole in distinct native aqueous matrices. An octyl restricted-access media bovine serum albumin column (RAM-BSA C(8)) was used in the first dimension, while a polysaccharide-based chiral column was used in the second dimension with either ultraviolet (UV-vis) or ion-trap tandem mass spectrometry (IT-MS/MS) detection. An in-line configuration was employed to assess the exclusion capacity of the RAM-BSA columns to humic substances. The excluded macromolecules had a molecular mass in the order of 18 kDa. Good selectivity, extraction efficiency, accuracy, and precision were achieved employing a very small amount (500 microL or 1.00 mL) of native water sample per injection, with detection limits of 5.00 microg L(-1), using UV-vis, and 0.0250 microg L(-1), using IT-MS/MS. The total analysis time was only 35 min, with no time spent on sample preparation. The methods were successfully applied to analyze a series of waste and estuarine water samples. The enantiomers were detected in an estuarine water sample collected from the Douro River estuary (Portugal) and in an influent sample from the wastewater treatment plant (WWTP) of São Carlos (Brazil). As far as we are concerned, this is the first report of the occurrence of (+)-omeprazole and (-)-omeprazole in native aqueous matrices.
Assuntos
Cromatografia Líquida/métodos , Omeprazol/análise , Omeprazol/química , Água/química , Animais , Bovinos , Substâncias Húmicas , Reprodutibilidade dos Testes , Estereoisomerismo , Espectrometria de Massas em Tandem , Eliminação de Resíduos LíquidosRESUMO
A method was optimized for the analysis of omeprazole (OMZ) by ultra-high speed LC with diode array detection using a monolithic Chromolith Fast Gradient RP 18 endcapped column (50 x 2.0 mm id). The analyses were performed at 30 degrees C using a mobile phase consisting of 0.15% (v/v) trifluoroacetic acid (TFA) in water (solvent A) and 0.15% (v/v) TFA in acetonitrile (solvent B) under a linear gradient of 5 to 90% B in 1 min at a flow rate of 1.0 mL/min and detection at 220 nm. Under these conditions, OMZ retention time was approximately 0.74 min. Validation parameters, such as selectivity, linearity, precision, accuracy, and robustness, showed results within the acceptable criteria. The method developed was successfully applied to OMZ enteric-coated pellets, showing that this assay can be used in the pharmaceutical industry for routine QC analysis. Moreover, the analytical conditions established allow for the simultaneous analysis of OMZ metabolites, 5-hydroxyomeprazole and omeprazole sulfone, in the same run, showing that this method can be extended to other matrixes with adequate procedures for sample preparation.
Assuntos
Omeprazol/análise , Inibidores da Bomba de Prótons/análise , Química Farmacêutica , Cromatografia Líquida de Alta Pressão , Indicadores e Reagentes , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Soluções , Comprimidos com Revestimento EntéricoRESUMO
To guarantee that an analytical procedure gives reliable, exact and interpretable information about a sample, it must be validated. Two ambiguous parameters are detection limit and quantification limit. The determination of these limits is still of great concern and there are still a variety of procedures described in the current literature. The fundamental objective of the present work is to apply the different recommendations suggested by official guidelines for the quantitative determination of omeprazole and its impurities (omeprazole sulphone and 5-hydroxy-omeprazole) in capsules and tablets using high performance liquid chromatography with UV detection. The importance of calibration linearity in the context of the quantification limit is considered, since one of the approaches, the estimated concentrations of this limit, are deduced from the regression line. The values of the detection limit and the quantification limit obtained show that, in chromatographic analyses, the best method is that based on the use of the parameters obtained from the analytical curve, which are statistically reliable. It was shown that smaller values of the detection limit and the quantification limit were obtained by the visual approach and by the method using the signal-to-noise ratio. However, these values may reflect a subjective evaluation, prone to error and large variations. This was confirmed by showing that these methods result in values that fall outside the linear range of the method.
Assuntos
Contaminação de Medicamentos , Omeprazol/análise , 2-Piridinilmetilsulfinilbenzimidazóis/análise , Cromatografia Líquida de Alta Pressão , Omeprazol/análogos & derivados , Omeprazol/normas , IncertezaRESUMO
The aim of this work is to develop and validate a dissolution test for rabeprazole sodium coated tablets using a reverse-phase liquid chromatographic method. After test sink conditions, dissolution medium and stability of the drug, the best conditions were: paddle at 75 rotations per minute (rpm) stirring speed, HCl 0.1 M and borate buffer pH 9.0 as dissolution medium for acidic and basic steps, respectively, volume of 900 ml for both. The quantitation method was also adapted and validated. Less than 10% of the label amount was released in the acid step, while more than 95% was achieved over 30 min in the basic one. The dissolution profile for tablets was considered satisfactory. The dissolution test developed was adequate for its purpose and could be applied for quality control of rabeprazole tablets, since there is no official monograph.
Assuntos
Benzimidazóis/análise , Omeprazol/análogos & derivados , Comprimidos/química , 2-Piridinilmetilsulfinilbenzimidazóis , Cromatografia Líquida de Alta Pressão/métodos , Concentração de Íons de Hidrogênio , Omeprazol/análise , Rabeprazol , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Solubilidade , Espectrofotometria UltravioletaRESUMO
A flow-injection biamperometric method for determination of pantoprazole (PTZ) in pharmaceutical tablets is reported for the first time. The reversible redox couples Fe3+/Fe2+, Fe(CN)6(3-)/Fe(CN)6(4-), Ce4+/Ce3+, VO3(-)NO2+, and I2/I- were tested as indicating redox systems for biamperometric determination of PTZ in a flow-injection assembly with optimized flow parameters. The best results were obtained using V03(-)NO2+, which showed to be a selective and sensitive biamperometric indicating system for PTZ even in the presence of excipients and antioxidants that typically are found in drugs. The analytical graph was linear (r = 0.99945) in the range from 10 to 100 mg/L using 25 mmol/L VO3(-) as the reagent and water as the carrier stream and applying 100 mV between the 2 platinum wire electrodes. The limits of detection and quantitation were 200 and 667 microg/L, respectively, with a sensibility of calibration of 22.6 mV/mg/L. The proposed method was successfully applied to determine PTZ in commercial pharmaceutical tablets with a mean relative error of 1.60% (n = 5) and mean relative standard deviation of 3.10%. Recoveries close to 100% showed good agreement between the expected amount of PTZ in tablets (40 mg) and the results found by the application of the proposed method and demonstrated that the formulations used in the tablet compositions do not interfere in the PTZ analysis. The system had good stability, with a relative standard deviation of 3.80% for 9 sequential injections of a 60 mg/L PTZ solution. A sampling rate of about 100 samples/h was obtained.
Assuntos
Benzimidazóis/análise , Técnicas de Química Analítica/métodos , Eletroquímica/métodos , Omeprazol/análogos & derivados , Sulfóxidos/análise , 2-Piridinilmetilsulfinilbenzimidazóis , Antiulcerosos/análise , Calibragem , Química Farmacêutica/métodos , Eletrodos , Análise de Injeção de Fluxo/métodos , Modelos Químicos , Omeprazol/análise , Oxirredução , Pantoprazol , Prótons , Reprodutibilidade dos Testes , Comprimidos , Tecnologia Farmacêutica/instrumentação , Tecnologia Farmacêutica/métodosRESUMO
Rabeprazole sodium is an antisecretory agent that inhibits the enzyme H+/K+ ATPase present in the stomach parietal cells. There are few data about its quantitative determinations in laboratorial routines. Capillary electrophoresis is a method being used increasingly for analysis of pharmaceutical compounds, the main advantages of which are the simplicity of instrumentation, low consumption of sample and reagents, and fast analysis. The aim of this study was to develop and validate a capillary electrophoresis method for determination of rabeprazole sodium in coated tablets. The conditions used were a bare fused silica capillary with 48.0 cm length (39.5 cm effective) and 75 microm id; a 10mM, pH 9.0, sodium tetraborate run buffer; a diode array detector set at 291 nm; hydrodynamic injection (50 mbar/5 s); and a voltage of 20 kV. HP Chemstation CE rev. A.06.03 software was used for system control, data acquisition, and analysis. The method was demonstrated to be linear in the concentration range of 5.0-40.0 microg/mL (r = 0.9993), precise (interday relative standard deviation = 0.49), accurate (mean recovery = 103.1%), and specific. The limits of detection and quantitation were 1.29 and 3.91 microg/mL, respectively.
Assuntos
Benzimidazóis/análise , Técnicas de Química Analítica/métodos , Eletroforese Capilar/métodos , Omeprazol/análogos & derivados , 2-Piridinilmetilsulfinilbenzimidazóis , Hidróxido de Amônia , Boratos/análise , Calibragem , Química Farmacêutica/métodos , Eletroforese Capilar/instrumentação , Inibidores Enzimáticos/análise , Concentração de Íons de Hidrogênio , Hidróxidos/análise , Modelos Químicos , Omeprazol/análise , Preparações Farmacêuticas/análise , Placebos , Rabeprazol , Reprodutibilidade dos Testes , Dióxido de Silício/análise , Hidróxido de Sódio/análise , Software , Tecnologia Farmacêutica/métodos , Fatores de Tempo , Raios UltravioletaRESUMO
The aim of the present study was to comparatively evaluate the stability of capsules containing 20 mg of Omeprazole, in enteric coated pellets, from seven pharmaceutical laboratories on Argentine market. The stability test was performed under the conditions indicated by the ICH: 40 degrees C, 75% HR, with and without light, during a six month period. The remaining content of Omeprazole, total percentage of impurities and percentage of released active principle in vitro, were determined by HPLC. The organoleptic characteristics of the pellets were visually examined. The results obtained at six months indicate that, from the seven products studied, four were found to have a content of Omeprazole higher than 90% of the labeled amount, in both lighting conditions tested, and also comply with the USP23 specifications with respect to the release in vitro. We conclude that the progressive darkening of the pellets indicates, qualitatively, the level of degradation of the product and that the stability of Omeprazole depends on the correct formulation and the primary container.