Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 966
Filtrar
1.
Artigo em Chinês | MEDLINE | ID: mdl-38686481

RESUMO

Objective:To investigate the predictive value of temporal bone high-resolution CT(HRCT) multiplanar reconstruction(MPR) for cerebrospinal fluid(CSF) gusher during cochlear implantation in patients with inner ear malformation. Methods:The clinical data of 33 patients(36 ears) with inner ear malformation who underwent cochlear implantation were retrospectively analyzed. The predictive value of HRCT for cerebrospinal fluid gusher during cochlear implantation was evaluated. Results:The width of the cochlear foramen(P=0.024, OR=1.735) and the diameter of the inner auditory meatus(P=0.022, OR=6.119) were independent risk factors for CSF gusher during cochlear implantation. The area under the curve(AUC) of cochlear foramen width in predicting intraoperative gusher was 0.851, the sensitivity was 93.33%, and the specificity was 61.90%. The AUC of the upper and lower diameter of the internal auditory canal for predicting intraoperative gusher was 0.848, the sensitivity was 80.00%, and the specificity was 80.95%. The AUC of cochlear foramen width combined with the upper and lower diameters of the internal auditory meatus for predicting intraoperative gusher was 0.930, the sensitivity was 80.00%, and the specificity was 95.24%. Conclusion:Based on temporal bone HRCT, the prediction model of cochlear foramen width combined with the upper and lower diameter of the internal auditory canal has crucial predictive value for the "gusher" during cochlear implantation in patients with inner ear malformation.


Assuntos
Implante Coclear , Orelha Interna , Tomografia Computadorizada por Raios X , Humanos , Implante Coclear/métodos , Estudos Retrospectivos , Feminino , Masculino , Tomografia Computadorizada por Raios X/métodos , Orelha Interna/anormalidades , Orelha Interna/diagnóstico por imagem , Pré-Escolar , Osso Temporal/diagnóstico por imagem , Osso Temporal/anormalidades , Lactente , Criança , Cóclea/anormalidades , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Fatores de Risco , Valor Preditivo dos Testes
2.
Comput Biol Med ; 171: 108168, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38432006

RESUMO

BACKGROUND: To develop an effective radiological software prototype that could read Digital Imaging and Communications in Medicine (DICOM) files, crop the inner ear automatically based on head computed tomography (CT), and classify normal and inner ear malformation (IEM). METHODS: A retrospective analysis was conducted on 2053 patients from 3 hospitals. We extracted 1200 inner ear CTs for importing, cropping, and training, testing, and validating an artificial intelligence (AI) model. Automated cropping algorithms based on CTs were developed to precisely isolate the inner ear volume. Additionally, a simple graphical user interface (GUI) was implemented for user interaction. Using cropped CTs as input, a deep learning convolutional neural network (DL CNN) with 5-fold cross-validation was used to classify inner ear anatomy as normal or abnormal. Five specific IEM types (cochlear hypoplasia, ossification, incomplete partition types I and III, and common cavity) were included, with data equally distributed between classes. Both the cropping tool and the AI model were extensively validated. RESULTS: The newly developed DICOM viewer/software successfully achieved its objectives: reading CT files, automatically cropping inner ear volumes, and classifying them as normal or malformed. The cropping tool demonstrated an average accuracy of 92.25%. The DL CNN model achieved an area under the curve (AUC) of 0.86 (95% confidence interval: 0.81-0.91). Performance metrics for the AI model were: accuracy (0.812), precision (0.791), recall (0.8), and F1-score (0.766). CONCLUSION: This study successfully developed and validated a fully automated workflow for classifying normal versus abnormal inner ear anatomy using a combination of advanced image processing and deep learning techniques. The tool exhibited good diagnostic accuracy, suggesting its potential application in risk stratification. However, it is crucial to emphasize the need for supervision by qualified medical professionals when utilizing this tool for clinical decision-making.


Assuntos
Inteligência Artificial , Orelha Interna , Humanos , Estudos Retrospectivos , Orelha Interna/diagnóstico por imagem , Orelha Interna/anormalidades , Redes Neurais de Computação , Software
3.
Int J Pediatr Otorhinolaryngol ; 178: 111875, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38364548

RESUMO

OBJECTIVES: To compared auditory and speech performance outcomes of children with cochlear implants (CI), between those with inner ear malformations (IEMs) and with normal ear anatomy; and to describe differences in electrophysiological measurements. STUDY DESIGN: A retrospective study. SETTING: A tertiary care pediatric medical center. PATIENTS: Forty-one children with IEMs who underwent CI during 2003-2017, and 41 age-matched CI recipients with normal ear anatomy (control group). MAIN OUTCOME MEASURES: Post-CI auditory performance outcomes including educational setting, Categories of Auditory Performance (CAP), and Speech Intelligibility Rating (SIR); and electrophysiological measurements, Including maximal comfortable electrical levels (CLs) and impedances along CI electrodes. RESULTS: The ANOVA on ranks revealed lower CAP scores in the study than control group: H3 = 18.8, P < 0.001. Among children with IEMs, CAP scores were better in children with enlarged vestibular aqueduct (EVA) (P < 0.04). SIR scores of the control group did not differ from those with isolated EVA; however, SIR scores of the IEMs without EVA subgroup were lower than all the other study subgroups (P < 0.01). The proportion of the control group that was integrated with full inclusion educational settings into the regular mainstream schools was higher than for those with IEMs without EVA (47 % vs. 15 %, P < 0.05), but similar to those with isolated EVA. For the study group versus control group, maximal comfortable electrical levels (CLs) were higher)P > 0.03) while impedance measurements were similar. CONCLUSIONS: Outcomes of pediatric recipients with normal anatomy were better than those with IEMs. Among pediatric recipients of CI with IEMs, auditory performance was better and CLs were lower among children with isolated EVA than all other IEM subgroups.


Assuntos
Implante Coclear , Implantes Cocleares , Orelha Interna , Percepção da Fala , Criança , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Orelha Interna/cirurgia , Orelha Interna/anormalidades , Percepção da Fala/fisiologia
4.
Acta Otolaryngol ; 143(sup1): S3-S16, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38109200

RESUMO

BACKGROUND: At present, there are not international unified standards and reports on Congenital Ear Malformation (CEM) in the world, which makes it difficult to transfer information and compare the literature. AIMS/OBJECTIVES: Through the statistical analysis of a large sample of CEM, a unified standard of all aspects of CEM is proposed and the data are provided for reference, which is convenient for the international work and literature comparison in this field. MATERIALS AND METHODS: Based on the author's 30 years of clinical and scientific research work on CEM and the relevant cases of 3231 (4714 ears) in our hospital, and combined with literature, statistical analysis was made. RESULTS: This paper summarizes the classification, definition, epidemiology, embryonic development, pathogenic factors of CEM and elaborates on the clinical manifestations, examination and sequence therapy of representative Congenital Malformation of the Middle and Outer Ear (CMMOE). We also introduce malformation of the auricle and inner ear, so as to cover the outer, middle and inner ear. At the same time, we introduce our achievements and contributions in this field. CONCLUSIONS AND SIGNIFICANCE: This study provides reference to the international unified standard and treatment principle of the CEM.


Assuntos
Pavilhão Auricular , Orelha Interna , Orelha Média/anormalidades , Orelha Externa , Orelha Interna/anormalidades
5.
Curr Probl Diagn Radiol ; 52(6): 576-585, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37500297

RESUMO

Inner ear malformation (IEM) with associated sensoryneural hearing loss (SNHL) is a major cause of childhood disability. Computed tomography (CT) and magnetic resonance imaging (MRI) imaging play important and often complementary roles in diagnosing underlying structural abnormalities and surgical planning allows for direct visualization of the cochlear nerve and is the preferred imaging modality prior to cochlear implantation. CT is helpful to assess osseous anatomy and when evaluating children with mixed hearing loss or syndromic associations. When reviewing these cases, it is important for the radiologist to be familiar with the key imaging features. In this article, we will present the imaging findings associated with different inner ear malformations associated with congenital sensorineural hearing loss.


Assuntos
Orelha Interna , Perda Auditiva Neurossensorial , Criança , Humanos , Orelha Interna/diagnóstico por imagem , Orelha Interna/anormalidades , Orelha Interna/patologia , Perda Auditiva Neurossensorial/diagnóstico por imagem , Perda Auditiva Neurossensorial/etiologia , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodos
6.
J Int Adv Otol ; 19(3): 266-268, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37272648

RESUMO

In this study, we present the first case with cerebellar herniation into the internal acoustic canal in incomplete partition type I anomaly. Cerebellar herniation into the internal acoustic canal is very rare with only a few cases reported in the literature. Although it is a rare clinical situation, cerebellar herniation into the internal acoustic canal may be seen in patients with incomplete partition type I. We presented magnetic resonance imaging findings of a 3-year-old girl with a history of meningitis, middle ear effusion, and bilateral congenital sensorineural hearing loss. Magnetic resonance imaging showed bilateral incomplete partition type I malformation and an additional flocculus herniation into the right internal acoustic canal. In the presented case, predisposition to cerebrospinal fluid leak in incomplete partition type I anomaly may be the reason for cerebellar herniation into internal acoustic canal. Also, possible increased intracranial pressure due to meningitis may be a contributing factor.


Assuntos
Orelha Interna , Perda Auditiva Neurossensorial , Feminino , Humanos , Pré-Escolar , Orelha Interna/anormalidades , Encefalocele/diagnóstico por imagem , Encefalocele/cirurgia , Tomografia Computadorizada por Raios X/métodos , Perda Auditiva Neurossensorial/patologia , Perda Auditiva Bilateral , Imageamento por Ressonância Magnética
7.
Rofo ; 195(10): 896-904, 2023 10.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-37348530

RESUMO

BACKGROUND: Since the introduction of hearing screening in Germany in 2009, pediatric hearing disorders are detected at an early stage. Early therapy is essential for language development. Imaging plays a central role in diagnosis and therapy planning. METHOD: Imaging findings of the most relevant causes of pediatric hearing disorders are presented. Specific attention is given to the method used in each case - CT or MRI. RESULTS AND CONCLUSIONS: While CT is the method of choice for conductive hearing loss, a combination of CT and MRI with high-resolution T2-3D sequences has been established as the best diagnostic method for sensorineural hearing loss. The most common causes of conductive hearing loss in childhood are chronic inflammation and cholesteatoma. Congenital malformations of the outer or middle ear are less frequent. In the case of sensorineural hearing loss, the cause is located in the inner ear and/or the cochlear nerve or the cerebrum. In these cases, congenital malformations are the most common cause. KEY POINTS: · CT and MRI are necessary to identify morphological causes of hearing disorders and to clarify the possibility of hearing-improving ear surgery or cochlear implantation.. · Contraindications for surgical procedures must be excluded.. · Anatomical variants that may be risk factors for surgery must be described.. CITATION FORMAT: · Sorge I, Hirsch F, Fuchs M et al. Imaging diagnostics for childhood hearing loss. Fortschr Röntgenstr 2023; 195: 896 - 904.


Assuntos
Orelha Interna , Perda Auditiva Neurossensorial , Perda Auditiva , Humanos , Criança , Perda Auditiva Condutiva/complicações , Tomografia Computadorizada por Raios X/métodos , Perda Auditiva Neurossensorial/diagnóstico por imagem , Perda Auditiva Neurossensorial/congênito , Orelha Interna/diagnóstico por imagem , Orelha Interna/anormalidades , Imageamento por Ressonância Magnética/métodos
8.
Artigo em Chinês | MEDLINE | ID: mdl-37150992

RESUMO

Objective: To explore the imaging evaluation of cerebrospinal fluid (CSF) otorrhea associated with inner ear malformation (IEM) in children. Methods: The clinical data of 28 children with CSF otorrhea associated with IEM confirmed by surgical exploration in Beijing Children's Hospital, from Nov, 2016 to Jan, 2021, were analyzed retrospectively,including 16 boys and 12 girls, aged from 8-month to 15-year and 8-month old, with a median age of 4-year old. The shapes of stapes were observed during the exploration surgery, and the imaging features of temporal bone high resolution CT(HRCT) and inner ear MRI pre- and post-operation were analyzed. Results: In 28 children with CSF otorrhea, 89.3%(25/28) had stapes footplates defect during exploration. Preoperative CT showed indirect signs such as IEM, tympanic membrane bulging, soft tissue in the tympanum and mastoid cavity. IEM included four kinds: incomplete partition type I (IP-Ⅰ), common cavity (CC), incomplete partition type Ⅱ (IP-Ⅱ), and cochlear aplasia (CA); 100%(28/28) presented with vestibule dilation; 85.7%(24/28) with a defect in the lamina cribrosa of the internal auditory canal. The direct diagnostic sign of CSF otorrrhea could be seen in 73.9%(17/23) pre-operative MRI: two T2-weighted hyperintense signals between vestibule and middle ear cavity were connected by slightly lower or mixed intense T2-weighted signals, and obvious in the coronal-plane; 100%(23/23) hyperintense T2-weighted signals in the tympanum connected with those in the Eustachian tube.In post-operative CT, the soft tissues in the tympanum and mastoid cavity decreased or disappeared as early as one week. In post-operative MRI, the hyperintense T2-weighted signals of tympanum and mastoid decreased or disappeared in 3 days to 1 month,soft tissues tamponade with moderate intense T2-weighted signal were seen in the vestibule in 1-4 months. Conclusions: IP-Ⅰ, CC, IP-Ⅱ and CA with dilated vestibule can lead to CSF otorrhea. Combined with special medical history, T2-weighted signal of inner ear MRI can provide diagnostic basie for most children with IEM and CSF otorrhea.HRCT and MRI of inner ear can also be used to evaluate the effect of surgery.


Assuntos
Otorreia de Líquido Cefalorraquidiano , Orelha Interna , Otorreia de Líquido Cefalorraquidiano/diagnóstico por imagem , Otorreia de Líquido Cefalorraquidiano/cirurgia , Orelha Interna/anormalidades , Orelha Interna/diagnóstico por imagem , Orelha Interna/cirurgia , Humanos , Masculino , Feminino , Criança , Adolescente , Adulto Jovem , Estudos Retrospectivos , Membrana Timpânica/anormalidades , Membrana Timpânica/diagnóstico por imagem , Imageamento por Ressonância Magnética , Processo Mastoide/anormalidades , Processo Mastoide/diagnóstico por imagem , Cóclea/anormalidades , Cóclea/diagnóstico por imagem , Tuba Auditiva/anormalidades , Tuba Auditiva/diagnóstico por imagem , Período Pré-Operatório , Período Pós-Operatório
9.
Int J Pediatr Otorhinolaryngol ; 168: 111522, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36990031

RESUMO

OBJECTIVE: To share our experience of the surgical challenges faced in cochlear implanted patients with inner ear malformation and to assess the auditory and speech perception outcomes. MATERIAL AND METHOD: Clinical records of 502 cochlear implant procedures were reviewed and data of 122 patients who had inner ear malformations were enrolled in the study. Their auditory and speech performances were evaluated post implantation for 3 years. RESULT: Cerebrospinal fluid gusher was encountered during opening of cochlea in 42 patients (34.4%) and one patient was re-explored within 24 h. In 30.3% of cases facial anomaly was found. Significant improvement in average performance was seen in all malformation types except in cochlear hypoplasia at 12 months postoperatively. CONCLUSION: Surgical challenges can be overcome with expertise and giving special attention to preoperative imaging. Our experience suggests that outcomes are favourable in patients with inner ear malformations too.


Assuntos
Implante Coclear , Implantes Cocleares , Orelha Interna , Humanos , Criança , Implante Coclear/métodos , Orelha Interna/cirurgia , Orelha Interna/anormalidades , Resultado do Tratamento , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Cóclea/anormalidades , Estudos Retrospectivos
10.
Mol Genet Genomic Med ; 11(5): e2168, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36934406

RESUMO

BACKGROUND: To date, over 400 syndromes with hearing impairment have been identified which altogether constitute almost 30% of hereditary hearing loss (HL) cases around the globe. Manifested as complete or partial labyrinthine aplasia (severe malformations of the inner ear structure), type I microtia (smaller outer ear with shortened auricles), and microdontia (small and widely spaced teeth), labyrinthine aplasia, microtia, and microdontia (LAMM) syndrome (OMIM 610706) is an extremely rare autosomal recessive condition caused by bi-allelic mutations in the FGF3 gene. METHODS: Using the whole-exome sequencing (WES) data of the proband, we analyzed a consanguineous Iranian family with three affected members presenting with congenital bilateral HL, type I microtia, and microdontia. RESULTS: We discovered the homozygous deletion c.45delC in the first exon of the FGF3 gene, overlapping a 38.72 Mb homozygosity region in chromosome 11. Further investigations using Sanger sequencing revealed that this variant co-segregated with the phenotype observed in the family. CONCLUSION: Here, we report the first identified case of LAMM syndrome in Iran, and by identifying a frameshift variant in the first exon of the FGF3 gene, our result will help better clarify the phenotype-genotype relation of LAMM syndrome.


Assuntos
Microtia Congênita , Surdez , Orelha Interna , Humanos , Microtia Congênita/genética , Surdez/genética , Orelha Interna/anormalidades , Mutação da Fase de Leitura , Homozigoto , Irã (Geográfico) , Deleção de Sequência , Síndrome
11.
Radiographics ; 43(4): e220102, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36893052

RESUMO

Sensorineural hearing loss results from abnormalities that affect the hair cells of the membranous labyrinth, inner ear malformations, and conditions affecting the auditory pathway from the cochlear nerve to the processing centers of the brain. Cochlear implantation is increasingly being performed for hearing rehabilitation owing to expanding indications and a growing number of children and adults with sensorineural hearing loss. An adequate understanding of the temporal bone anatomy and diseases that affect the inner ear is paramount for alerting the operating surgeon about variants and imaging findings that can influence the surgical technique, affect the choice of cochlear implant and electrode type, and help avoid inadvertent complications. In this article, imaging protocols for sensorineural hearing loss and the normal inner ear anatomy are reviewed, with a brief description of cochlear implant devices and surgical techniques. In addition, congenital inner ear malformations and acquired causes of sensorineural hearing loss are discussed, with a focus on imaging findings that may affect surgical planning and outcomes. The anatomic factors and variations that are associated with surgical challenges and may predispose patients to periprocedural complications also are highlighted. © RSNA, 2023 Quiz questions for this article are available through the Online Learning Center. Online supplemental material and the slide presentation from the RSNA Annual Meeting are available for this article.


Assuntos
Implante Coclear , Implantes Cocleares , Orelha Interna , Perda Auditiva Neurossensorial , Criança , Adulto , Humanos , Implante Coclear/efeitos adversos , Implante Coclear/métodos , Perda Auditiva Neurossensorial/diagnóstico por imagem , Perda Auditiva Neurossensorial/cirurgia , Perda Auditiva Neurossensorial/etiologia , Orelha Interna/anormalidades , Orelha Interna/cirurgia , Implantes Cocleares/efeitos adversos , Osso Temporal/anatomia & histologia
12.
Int J Pediatr Otorhinolaryngol ; 166: 111483, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36774737

RESUMO

PURPOSE: This study investigated the correlation between the diameter of the bony cochlear nerve canal (BCNC), as determined by Temporal bone CT, and MRI findings of cochlear nerves (CN) in children with sensorineural hearing loss (SNHL). MATERIALS AND METHODS: A prospective study design was followed. Radiological data (Temporal bone CT and MRI) of fifty children with sensorineural hearing loss (age <18 y) were included in the study. All patients (100 ears) underwent routine MRI protocol in addition to 3D CISS (3-D constructive interference in steady state). RESULTS: Based on CT findings, the BCNC was classified according to its diameter into three groups; group 1 (<1.4 mm), group 2 (1.4-2.0 mm), and group 3 (>2.0 mm). A significant difference between the three groups at degrees of SNHL (p < 0.001) was observed. Significant difference (p < 0.001) was also observed in the mean level of pure tone audiometry (PTA) average in group 1 compared to group 2. The CN was absent in 20 ears of group 1 CT results (29%), CN hypoplasia was noticed in 40 ears of group 1 CT (58%). However, CN was present in 9 ears of group 1 CT (13%), while in group 2 and 3, CN was present in 100% of the cases (27, and 4 ears, respectively, p < 0.001). CONCLUSIONS: MRI and CT imaging are valuable in the diagnosis of SNHL in children. Moreover, with BCNC stenosis, there was a high probability of CN aplasia or hypoplasia.


Assuntos
Orelha Interna , Perda Auditiva Neurossensorial , Criança , Humanos , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Perda Auditiva Neurossensorial/diagnóstico , Orelha Interna/anormalidades , Nervo Coclear/anormalidades , Imageamento por Ressonância Magnética , Estudos Retrospectivos
13.
Neuroradiology ; 65(4): 819-834, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36715725

RESUMO

PURPOSE: We reviewed the genotypes and the imaging appearances of cochleae in CHARGE patients from two large tertiary centres and analysed the observed cochlear anomalies, providing detailed anatomical description and a grading system. The goal was to gain insight into the spectrum of cochlear anomalies in CHARGE syndrome, and thus, in the role of the CHD7 gene in otic vesicle development. METHODS: We retrospectively reviewed CT and/or MR imaging of CHARGE patients referred to our institutions between 2005 and 2022. Cochlear morphology was analysed and, when abnormal, divided into 3 groups in order of progressive severity. Other radiological findings in the temporal bone were also recorded. Comparison with the existing classification system of cochlear malformation was also attempted. RESULTS: Cochlear morphology in our CHARGE cohort ranged from normal to extreme hypoplasia. The most common phenotype was cochlear hypoplasia in which the basal turn was relatively preserved, and the upper turns were underdeveloped. All patients in the cohort had absent or markedly hypoplastic semicircular canals and small, misshapen vestibules. Aside from a stenotic cochlear aperture (fossette) being associated with a hypoplastic or absent cochlear nerve, there was no consistent relationship between cochlear nerve status (normal, hypoplasia, or aplasia) and cochlear morphology. CONCLUSION: Cochlear morphology in CHARGE syndrome is variable. Whenever the cochlea was abnormal, it was almost invariably hypoplastic. This may shed light on the role of CHD7 in cochlear development. Accurate morphological description of the cochlea contributes to proper clinical diagnosis and is important for planning surgical treatment options.


Assuntos
Síndrome CHARGE , Orelha Interna , Humanos , Síndrome CHARGE/diagnóstico por imagem , Síndrome CHARGE/genética , Síndrome CHARGE/complicações , Estudos Retrospectivos , Orelha Interna/diagnóstico por imagem , Orelha Interna/anormalidades , Cóclea/diagnóstico por imagem , Cóclea/anormalidades , Desenvolvimento Embrionário , DNA Helicases/genética , Proteínas de Ligação a DNA/genética
14.
Eur Arch Otorhinolaryngol ; 280(5): 2149-2154, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36210370

RESUMO

PURPOSE: A narrow bony internal auditory canal (IAC) may be associated with a hypoplastic cochlear nerve and poorer hearing performances after cochlear implantation. However, definitions for a narrow IAC vary widely and commonly, qualitative grading or two-dimensional measures are used to characterize a narrow IAC. We aimed to refine the definition of a narrow IAC by determining IAC volume in both control patients and patients with inner ear malformations (IEMs). METHODS: In this multicentric study, we included high-resolution CT (HRCT) scans of 128 temporal bones (85 with IEMs: cochlear aplasia, n = 11; common cavity, n = 2; cochlear hypoplasia type, n = 19; incomplete partition type I/III, n = 8/8; Mondini malformation, n = 16; enlarged vestibular aqueduct syndrome, n = 19; 45 controls). The IAC diameter was measured in the axial plane and the IAC volume was measured by semi-automatic segmentation and three-dimensional reconstruction. RESULTS: In controls, the mean IAC diameter was 5.5 mm (SD 1.1 mm) and the mean IAC volume was 175.3 mm3 (SD 52.6 mm3). Statistically significant differences in IAC volumes were found in cochlear aplasia (68.3 mm3, p < 0.0001), IPI (107.4 mm3, p = 0.04), and IPIII (277.5 mm3, p = 0.0004 mm3). Inter-rater reliability was higher in IAC volume than in IAC diameter (intraclass correlation coefficient 0.92 vs. 0.77). CONCLUSIONS: Volumetric measurement of IAC in cases of IEMs reduces measurement variability and may add to classifying IEMs. Since a hypoplastic IAC can be associated with a hypoplastic cochlear nerve and sensorineural hearing loss, radiologic assessment of the IAC is crucial in patients with severe sensorineural hearing loss undergoing cochlear implantation.


Assuntos
Orelha Interna , Perda Auditiva Neurossensorial , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Orelha Interna/diagnóstico por imagem , Orelha Interna/anormalidades , Cóclea/diagnóstico por imagem , Perda Auditiva Neurossensorial/diagnóstico por imagem , Perda Auditiva Neurossensorial/cirurgia
15.
Ear Nose Throat J ; 102(4): 227-230, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33624550

RESUMO

Stapes gusher is a massive flow of perilymph and cerebrospinal fluid leak that fills the middle ear immediately after surgical opening of the labyrinth, such as during stapedectomy. Stapes gusher usually occurs as the result of a congenital malformation that causes an abnormal communication between the perilymphatic space and the subarachnoid space involving the internal auditory canal or the cochlear duct. To date, the potential risk of stapes gusher cannot be assessed preoperatively, as there are not pathognomonic signs suggestive of this complication. However, high-resolution computed tomography scan (HRCT) of the temporal bone can provide information that may help recognizing patients at risk. Recently, an anatomic evaluation of the inner ear with oblique reformation at HRCT has been described. This reformation offers a new and more detailed topographic vision of temporal bone structures compared to the classic axial and coronal planes and may help identifying anatomical alterations otherwise not visible. In this article, we present a case of stapes gusher and the role of preoperative HRCT with oblique reformation in its prevention.


Assuntos
Orelha Interna , Cirurgia do Estribo , Humanos , Cirurgia do Estribo/efeitos adversos , Orelha Interna/anormalidades , Vazamento de Líquido Cefalorraquidiano/diagnóstico por imagem , Vazamento de Líquido Cefalorraquidiano/etiologia , Vazamento de Líquido Cefalorraquidiano/cirurgia , Estribo/diagnóstico por imagem , Estribo/anormalidades , Osso Temporal/diagnóstico por imagem , Osso Temporal/cirurgia , Tomografia Computadorizada por Raios X
16.
J Int Adv Otol ; 18(6): 478-481, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36349668

RESUMO

BACKGROUND: It is aimed to investigate the incidence of cerebrospinal fluid gusher in cochlear implantation and the association between cerebrospinal fluid gusher and inner-ear malformations in adult and pediatric patients. METHODS: A retrospective case review of 1025 primary cochlear implantation procedures was performed. Patients with inner-ear malformation or cerebrospinal fluid gusher during primary cochlear implantation were included and divided into 2 groups according to age: pediatric and adult groups. RESULTS: The incidence of inner-ear malformation was 4.19% (17/405) and 7.6% (47/620) in the adult and pediatric groups, respectively. There was a significant difference in the incidence of inner-ear malformation in the pediatric group. The incidence of cerebrospinal fluid gusher was 0.9% (4/405) and 4.1% (26/620) in the adult and pediatric groups, respectively. There was a significant difference in the incidence of gusher between the adult and pediatric groups. CONCLUSION: The incidence of a cerebrospinal fluid gusher is higher in the pediatric group, compared to adults due to a higher rate of inner-ear malformation. Inner-ear malformation poses a risk factor for cerebrospinal fluid gusher.


Assuntos
Implante Coclear , Implantes Cocleares , Orelha Interna , Adulto , Humanos , Criança , Implante Coclear/métodos , Estudos Retrospectivos , Orelha Interna/cirurgia , Orelha Interna/anormalidades , Implantes Cocleares/efeitos adversos , Otorreia de Líquido Cefalorraquidiano/epidemiologia , Otorreia de Líquido Cefalorraquidiano/etiologia
18.
Int J Pediatr Otorhinolaryngol ; 160: 111243, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35853403

RESUMO

OBJECTIVES: To assess the quality of life (QoL) in child and adolescent cochlear implant users with inner ear malformations (IEM) and to compare their outcomes to their cochlear implant using peers with normal inner ear structures. METHODS: The present sample consisted of 100 children (45 with IEM, 55 without IEM) and 100 adolescents (46 with IEM, 54 without IEM). The following QoL questionnaires were used to assess the hearing-related QoL: The Hearing Environments and Reflection on Quality of Life 26 (HEAR-QL-26 for children between 7 and 12 years of age) and HEAR-QL-28 (for adolescents between 13 and 18 years of age). Both questionnaires were based on a 5-points Likert scale from 0 to 4, with higher scores indicating a better perception of QoL. The scores were converted to percentage values (never = 100, almost never = 75, sometimes = 50, often = 25, almost always = 0). RESULTS: For the patients with IEM, mean scores from the HEAR-QL-26 and HEAR-QL-28 were 50.4 (SD = 18.9) and 54.5 (SD = 19.6), respectively. For the patients without IEM, mean scores from the HEAR-QL-26 and HEAR-QL-28 were 72.7 (SD = 18.0) and 65.0 (SD = 19.1), respectively. For both child and adolescent subgroups, statistically significant differences were observed between QoL scores from patients with and without IEM (p < 0.001). There were no statistically significant effects of the malformation type on the QoL findings (p ≥ 0.05). CONCLUSION: Child and adolescent cochlear implant users with IEM had significantly lower scores on validated HEAR-QL versions in comparison to their implanted peers without IEM.


Assuntos
Implante Coclear , Implantes Cocleares , Orelha Interna , Percepção da Fala , Adolescente , Adulto , Criança , Orelha Interna/anormalidades , Audição , Humanos , Qualidade de Vida
19.
Comput Biol Med ; 147: 105683, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35667154

RESUMO

BACKGROUND AND PURPOSE: To examine the diagnostic performance of unsupervised deep learning using a 3D variational autoencoder (VAE) for detecting and localizing inner ear abnormalities on CT images. METHOD: Temporal bone CT images of 6663 normal inner ears and 113 malformations were analyzed. For unsupervised learning, 113 images from both the malformation and normal cases were used as test data. Other normal images were used for training. A colored difference map representing differences between input and output images of 3D-VAE and the ratio of colored to total pixel numbers were calculated. Supervised learning was also investigated using a 3D deep residual network and all data were classified as normal or malformation using 10-fold cross-validation. RESULTS: For unsupervised learning, a significant difference in the colored pixel ratio was seen between normal (0.00021 ± 0.00022) and malformation (0.00148 ± 0.00087) cases with an area under the curve of 0.99 (specificity = 92.0%, sensitivity = 99.1%). Upon evaluation of the difference map, abnormal regions were partially and not highlighted in 7% and 0% of the malformations, respectively. For supervised learning, which achieved 99.8% specificity and 90.3% sensitivity, a part of and no abnormal regions were highlighted on interpretation maps in 34% and 8% of the malformations, respectively. Abnormal regions were not highlighted in 4 malformation cases diagnosed as malformations and were highlighted in 6 cases misdiagnosed as normal. CONCLUSIONS: Unsupervised deep learning of 3D-VAE precisely detected inner ear malformations and localized abnormal regions. Supervised learning did not identify whole abnormal regions frequently and basis for diagnosis was sometimes unclear.


Assuntos
Aprendizado Profundo , Orelha Interna , Orelha Interna/anormalidades , Orelha Interna/diagnóstico por imagem , Osso Temporal , Tomografia Computadorizada por Raios X
20.
J Int Adv Otol ; 18(3): 203-209, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35608487

RESUMO

BACKGROUND: Cochlear implants are arguably the most successful neural prosthesis today. Cochlear implantation has several difficulties in patients with internal ear anomalies. This study was performed to analyze intraoperative, postoperative findings, and auditory performance of 55 patients who had inner ear malformations and were treated with cochlear implants at Otorhinolaryngology Department of Çukurova University Hospital. METHODS: Auditory performances were analyzed in 30 of 55 patients. Patients with cochlear anomalies were evaluated as group I, patients with vestibular malformation as group II, and patients with the normal bone labyrinth as group III. Listening progress profiles and meaningful auditory integration scale tests were used to determine performances. RESULTS: Comparison between the listening progress profiles test performance of the groups at 12th and 18th month of group I was significantly lower than other groups (P < .05) and reached at the same level after the 24th month. Comparison between the meaningful auditory integration scale test performance of groups at 24th and 36th month of group I was significantly lower than other groups (P < .05). Perilymph gusher was observed in 3 patients who had incomplete partition I malformation. Oozing was observed in 50% of incomplete partition II patients. Facial nerve traced a variant course in 4 of 55 patients and 6 patients had postoperative meningitis. CONCLUSION: Initially patients with inner ear anomalies showed that the level of language development was worse than patients with normal bone anatomy. However, it was shown that they both reached the same point as a result. Facial nerve anomaly and meningitis risk is higher in patients with inner ear malformations.


Assuntos
Implante Coclear , Implantes Cocleares , Orelha Interna , Implante Coclear/métodos , Orelha Interna/anormalidades , Orelha Interna/cirurgia , Testes Auditivos , Humanos , Perilinfa , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...