J Hypertens ; 42(6): 1075-1085, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38690906

RESUMO

Most non-invasive blood pressure (BP) measurements are carried out using instruments which implement either the Ratio or the Maximum Gradient oscillometric method, mostly during cuff deflation, but more rarely during cuff inflation. Yet, there is little published literature on the relative advantages and accuracy of these two methods. In this study of 40 lightly sedated individuals aged 64.1 ± 9.6 years, we evaluate and compare the performance of the oscillometric ratio (K) and gradient (Grad) methods for the non-invasive estimation of mean pressure, SBP and DBP with reference to invasive intra-arterial values. There was no significant difference between intra-arterial estimates of mean pressure made via Korotkoff sounds (MP-OWE) or the gradient method (MP-Grad). However, 17.7% of MP-OWE and 15% of MP-Grad were in error by more than 10 mmHg. SBP-K and SBP-Grad underestimated SBP by 14 and 18 mmHg, whilst accurately estimating DBP with mean errors of 0.4 ±â€Š5.0 and 1.7 ±â€Š6.1 mmHg, respectively. Relative to the reference standard SBP-K, SBP-Grad and DBP-Grad were estimated with a mean error of -4.5 ±â€Š6.6 and 1.4 ±â€Š5.6 mmHg, respectively, noting that using the full range of recommended ratios introduces errors of 12 and 7 mmHg in SBP and DBP, respectively. We also show that it is possible to find ratios which minimize the root mean square error (RMSE) and the mean error for any particular individual cohort. We developed linear models for estimating SBP and SBP-K from a range of demographic and non-invasive OWE variables with resulting mean errors of 0.15 ±â€Š5.6 and 0.3 ±â€Š5.7 mmHg, acceptable according to the Universal standard.


Assuntos
Determinação da Pressão Arterial , Pressão Sanguínea , Oscilometria , Humanos , Pessoa de Meia-Idade , Determinação da Pressão Arterial/métodos , Masculino , Feminino , Oscilometria/métodos , Idoso , Pressão Sanguínea/fisiologia
2.
PLoS One ; 19(5): e0302793, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38739601

RESUMO

BACKGROUND: In cardiology, cardiac output (CO) is an important parameter for assessing cardiac function. While invasive thermodilution procedures are the gold standard for CO assessment, transthoracic Doppler echocardiography (TTE) has become the established method for routine CO assessment in daily clinical practice. However, a demand persists for non-invasive approaches, including oscillometric pulse wave analysis (PWA), to enhance the accuracy of CO estimation, reduce complications associated with invasive procedures, and facilitate its application in non-intensive care settings. Here, we aimed to compare the TTE and oscillometric PWA algorithm Antares for a non-invasive estimation of CO. METHODS: Non-invasive CO data obtained by two-dimensional TTE were compared with those from an oscillometric blood pressure device (custo med GmbH, Ottobrunn, Germany) using the integrated algorithm Antares (Redwave Medical GmbH, Jena, Germany). In total, 59 patients undergoing elective cardiac catheterization for clinical reasons (71±10 years old, 76% males) were included. Agreement between both CO measures were assessed by Bland-Altman analysis, Student's t-test, and Pearson correlations. RESULTS: The mean difference in CO was 0.04 ± 1.03 l/min (95% confidence interval for the mean difference: -0.23 to 0.30 l/min) for the overall group, with lower and upper limits of agreement at -1.98 and 2.05 l/min, respectively. There was no statistically significant difference in means between both CO measures (P = 0.785). Statistically significant correlations between TTE and Antares CO were observed in the entire cohort (r = 0.705, P<0.001) as well as in female (r = 0.802, P<0.001) and male patients (r = 0.669, P<0.001). CONCLUSIONS: The oscillometric PWA algorithm Antares and established TTE for a non-invasive estimation of CO are highly correlated in male and female patients, with no statistically significant difference between both approaches. Future validation studies of the Antares CO are necessary before a clinical application can be considered.


Assuntos
Algoritmos , Débito Cardíaco , Ecocardiografia Doppler , Análise de Onda de Pulso , Humanos , Masculino , Feminino , Débito Cardíaco/fisiologia , Idoso , Análise de Onda de Pulso/métodos , Ecocardiografia Doppler/métodos , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Oscilometria/métodos
3.
BMC Pediatr ; 24(1): 296, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702638

RESUMO

BACKGROUND: Cough variant asthma (CVA) is one of the most common causes of chronic cough in children worldwide. The diagnosis of CVA in children remains challenging. This study aimed to assess the diagnostic utility of impulse oscillometry (IOS) pulmonary function in children with CVA. METHODS: This study included children aged 4 to 12 years diagnosed with CVA who underwent IOS pulmonary function and bronchodilation (BD) tests. A control group of healthy children was matched. Pre- and post-BD IOS parameters were recorded and presented as mean ± standard deviation or median. Receiver operating characteristic (ROC) curves were plotted, and the area under the curve (AUC) was calculated to evaluate the discriminatory potential of the IOS parameters for diagnosing CVA. RESULTS: A total of 180 patients with CVA and 65 control subjects were included. The baseline IOS parameters in the CVA group, except X5%pred, were significantly greater compared to the control group. After inhalation of salbutamol sulfate, all IOS parameters improved significantly in the CVA group. However, Z5%pred, R5%pred, and R20%pred remained greater in the CVA group compared to the control group. The improvement rates of IOS parameters in the CVA group significantly surpassed those in the control group. The ROC curve results for pre-BD IOS parameters and the improvement rate during the BD test showed that the combinations of pre-Z5%pred+△Z5% and pre-R5%pred+△R5% achieved the highest AUC value of 0.920 and 0.898, respectively. The AUC values of these combined parameters surpassed those of individual ones. CONCLUSIONS: This study highlights that children with CVA exhibit greater IOS parameters compared to healthy children. The changes in IOS parameters during the BD test provided valuable diagnostic information for CVA, and the combination of various parameters can help pediatricians accurately identify CVA in children.


Assuntos
Asma , Tosse , Oscilometria , Humanos , Tosse/etiologia , Tosse/diagnóstico , Criança , Asma/diagnóstico , Asma/fisiopatologia , Masculino , Feminino , Oscilometria/métodos , Pré-Escolar , Estudos de Casos e Controles , Curva ROC , Albuterol , Testes de Função Respiratória/métodos , Broncodilatadores , Variante Tussígena da Asma
4.
Blood Press ; 33(1): 2338208, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38591393

RESUMO

OBJECTIVE: Some brachial cuffs for oscillometric blood pressure (BP) measurement are claimed to cover a wide range of upper-arm circumferences; however, their validation is rarely conducted. Our aim was to compare oscillometric BP measurements obtained with a universal cuff with those obtained with an appropriately sized cuff. METHODS: We utilised the Microlife B6 Connect monitor, conducting oscillometric BP measurements in a random sequence with both a universal cuff (recommended for arm circumferences from 22 to 42 cm) and an appropriately sized cuff (medium for circumference 22-32 cm and large for 32-42 cm). We included 91 individuals with an arm circumference of 22-32 cm and 64 individuals with an arm circumference of 32-42 cm. RESULTS: For arm circumferences > 32 cm, systolic and diastolic BP measured with the universal cuff was higher than that measured with the large cuff (systolic 6.4 mmHg, 95% confidence interval [CI]). 3.9-8.8, diastolic 2.4 mmHg, 95%CI, 1.2-3.7, p < 0.001 for both). Overestimation of BP with the universal cuff was statistically significant after correcting for the sequence of measurements. No statistical difference was found between the universal cuff and medium cuff for circumferences in the 22-32 cm range. The bladder size in the universal cuff matched the dimensions of the medium-sized cuff; however, the cuff was larger. CONCLUSION: Overestimation of BP measured with a universal cuff in persons with large arm circumferences is clinically important. It poses the risk of unnecessary initiation or intensification of antihypertensive medication in persons using the universal cuff.


What is the context?Clinical guidelines recommend individualisation of the size of the cuff used for blood pressure measurement according to the circumference of the upper arm.Many blood pressure monitors are sold with a single "universal" cuff claimed to cover a wide range of upper arm sizes.We compared blood pressure obtained with the Microlife B6 Connect monitor and a "universal" cuff with the results obtained with individual sized cuffs (medium size for arm circumference between 22 and 32 cm and large size for arm circumference between 32 and 42 cm).What is new?In persons with large upper arm circumference is the systolic blood pressure 6.4 mmHg higher and the diastolic blood pressure 2.4 mmHg higher with the universal cuff than with the individual-sized large cuff.What is the impact?The universal cuff overestimates blood pressure in persons with large arm circumference.


Assuntos
Determinação da Pressão Arterial , Extremidade Superior , Humanos , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Oscilometria/métodos , Diástole , Monitores de Pressão Arterial
5.
J Feline Med Surg ; 26(3): 1098612X241231471, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38546192

RESUMO

OBJECTIVES: Systemic arterial hypertension is a common occurrence and can have serious adverse consequences in cats. Therefore, measuring blood pressure is very important. There are many indirect blood pressure measurement devices available. This study compared Doppler, oscillometric (petMAP Graphic II, SunTech Vet20, the Cardell Insight-X0000) and high-definition oscillometry devices for the non-invasive measurement of blood pressure in conscious cats. METHODS: In this prospective study, blood pressure was measured in 32 cats using the different devices according to the recommendations of the American College of Veterinary Internal Medicine Consensus Statement. Blood pressures (systolic blood pressure [SBP], diastolic blood pressure [DBP], mean arterial pressure [MAP]), time to complete measurements, number of attempts needed, coefficient of variation (CV) between the blood pressure measurements of the different devices, ease of completing measurements and apparent stress level of the cat were assessed. RESULTS: There was a significant difference between devices in the time taken to obtain blood pressure readings and the number of attempts necessary to obtain six reliable measurements. The CV of the Doppler device was significantly smaller than that of the rest of the devices, but there were no other differences between the devices. The mean SBP, DBP and MAP measured by the petMAP device were significantly higher than the measurements from the other devices. The perceived ease of measurement was not significantly different between the various machines. The perceived level of stress of measurement with the Doppler device was significantly higher compared with the other devices but did not lead to an increased SBP. CONCLUSIONS AND RELEVANCE: Using a Doppler device to measure blood pressure in conscious cats is fast, relatively easy and gives reliable results. A disadvantage is that the Doppler device can only measure SBP, while oscillometric devices also provide DBP and MAP. However, in veterinary medicine, systolic hypertension is considered the most relevant.


Assuntos
Determinação da Pressão Arterial , Ultrassom , Gatos , Animais , Pressão Sanguínea/fisiologia , Oscilometria/veterinária , Oscilometria/métodos , Estudos Prospectivos , Determinação da Pressão Arterial/veterinária
6.
Rev. patol. respir ; 27(1): 27-30, ene.-mar2024. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-231681

RESUMO

La oscilometría es una herramienta que, poco a poco, se está abriendo paso en las consultas de neumología y alergología. Se trata de una técnica sencilla de realizar para el paciente, que, además, aporta información adicional a las pruebas de función respiratoria clásicas. No solamente nos indica la alteración que existe en la vía aérea, sino que localiza a qué altura se produce (central o periférica). El objetivo es acercar esta técnica al personal sanitario y hacer más sencilla su interpretación. (AU)


Oscillometry is a tool that is gradually making its way into the daily routine of pneumology and allergology. It is a simple technique for the patient, which also provides additional information to the classic respiratory function tests. It not only indicates if there is an alteration in the airway, but also locates where it occurs (central or peripheral). The aim is to bring this technique closer to healthcare professionals and facilitate its interpretation. (AU)


Assuntos
Humanos , Fisiologia , Oscilometria , Pneumologia , Alergia e Imunologia , Pulmão
7.
Medicina (Kaunas) ; 60(3)2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38541172

RESUMO

Background and Objectives: Data on characteristics of asthma in children with sickle cell disease (SCD) is conflicting. Recently, the L-arginine pathway has gained attention in the pathogenesis of asthma and SCD. This study aimed to determine the distinctive clinical and laboratory features and the role of arginine metabolism in asthmatic children with SCD. Materials and Methods: A total of 52 children and adolescents with SCD, including 24 with asthma (SCD-A) and 28 without asthma (SCD-NA), and 40 healthy controls were included. A questionnaire, atopy tests, fractional exhaled nitric oxide (FeNO), and lung function tests were employed. Serum metabolites of the arginine pathway were measured. The results of the three groups were compared. Results: The demographic characteristics and atopy markers of the three groups were similar. FEV1%, FEV1/FVC, MMEF%, and total lung capacity (TLC%) values of SCD-A patients were not significantly different from the SCD-NA group, but they were significantly lower than the values measured in the controls. FeNO values greater than 35 ppb were present only in the SCD-A group. In impulse oscillometry, median resistance values at 5 Hz (R5)% were higher in both SCD subgroups than in healthy controls (p = 0.001). The (R5-20/R5)% values were higher in the SCD-A group (p = 0.028). Serum arginine levels and arginine bioavailability indices were significantly lower in the SCD-A group than in the SCD-NA group and healthy controls (p = 0.003 and p < 0.001). Conclusions: Asthma in children with SCD was not associated with atopy or low FEV1/FVC levels. However, lower arginine bioavailability and higher FeNO levels differentiated asthma in patients with SCD. High R5% and (R5-20/R5)% values indicated increased airway resistance in SCD, with a predominance of small airway disease in asthmatics.


Assuntos
Anemia Falciforme , Asma , Criança , Adolescente , Humanos , Adulto Jovem , Resistência das Vias Respiratórias , Teste da Fração de Óxido Nítrico Exalado , Disponibilidade Biológica , Oscilometria/métodos , Espirometria , Óxido Nítrico/metabolismo , Testes de Função Respiratória , Anemia Falciforme/complicações
8.
Respir Res ; 25(1): 149, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38555433

RESUMO

BACKGROUND: The clinical significance of the impulse oscillometry-defined small airway bronchodilator response (IOS-BDR) is not well-known. Accordingly, this study investigated the clinical characteristics of IOS-BDR and explored the association between lung function decline, acute respiratory exacerbations, and IOS-BDR. METHODS: Participants were recruited from an Early Chronic Obstructive Pulmonary Disease (ECOPD) cohort subset and were followed up for two years with visits at baseline, 12 months, and 24 months. Chronic obstructive pulmonary disease (COPD) was defined as a post-bronchodilator forced expiratory volume in 1 s (FEV1)/forced vital capacity (FVC) ratio < 0.70. IOS-BDR was defined as meeting any one of the following criteria: an absolute change in respiratory system resistance at 5 Hz ≤ - 0.137 kPa/L/s, an absolute change in respiratory system reactance at 5 Hz ≥ 0.055 kPa/L/s, or an absolute change in reactance area ≤ - 0.390 kPa/L. The association between IOS-BDR and a decline in lung function was explored with linear mixed-effects model. The association between IOS-BDR and the risk of acute respiratory exacerbations at the two-year follow-up was analyzed with the logistic regression model. RESULTS: This study involved 466 participants (92 participants with IOS-BDR and 374 participants without IOS-BDR). Participants with IOS-BDR had higher COPD assessment test and modified Medical Research Council dyspnea scale scores, more severe emphysema, air trapping, and rapid decline in FVC than those without IOS-BDR over 2-year follow-up. IOS-BDR was not associated with the risk of acute respiratory exacerbations at the 2-year follow-up. CONCLUSIONS: The participants with IOS-BDR had more respiratory symptoms, radiographic structural changes, and had an increase in decline in lung function than those without IOS-BDR. TRIAL REGISTRATION: Chinese Clinical Trial Registry, ChiCTR1900024643. Registered on 19 July, 2019.


Assuntos
Asma , Doença Pulmonar Obstrutiva Crônica , Humanos , Broncodilatadores/uso terapêutico , Asma/diagnóstico , Oscilometria , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Testes de Função Respiratória , Volume Expiratório Forçado , Espirometria
9.
Clinics (Sao Paulo) ; 79: 100313, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38490138

RESUMO

INTRODUCTION: Studies suggest peripheral airway abnormalities in Pulmonary Arterial Hypertension (PAH). Impulse Oscillometry (IOS) is a noninvasive and sensitive technique for assessing the small airways. It evaluates the impedance of the respiratory system ‒ Resistance (R) and reactance (X) ‒ to a pulse of sound waves sent to the lungs, in a range of frequencies (5‒20 Hz). METHOD: Resistance variables: R5, R20, R5-R20 and reactance variables: AX (reactance area) and Fres (resonance frequency). The aim is to evaluate R and X in patients with idiopathic PAH (IPAH) and to investigate whether there is a correlation between IOS and spirometry. RESULTS: Thirteen IPAH patients and 11 healthy subjects matched for sex and age underwent IOS and spirometry. IPAH patients had lower FVC and FEV1 values (p < 0.001), VEF1/CVF (p = 0.049) and FEF 25-75 (p = 0.006) than healthy patients. At IOS, IPAH patients showed lower tidal volumes and higher AX (p < 0.05) compared to healthy individuals, and 53.8 of patients had R5-R20 values ≥ 0.07 kPa/L/s. Correlation analysis: X5, AX, R5-R20 and Fres showed moderate correlation with FVC (p = 0.036 r = 0.585, p = 0.001 r = -0.687, p = 0.005 r = -0.726 and p = 0.027 r = -0.610); Fres (p = 0.012 r = -0.669) and AX (p = 0.006 r = -0.711) correlated with FEV1; [R5 and R20, (R5-R20)] also correlated with FEV1 (p < 0.001 r = -0.573, p = 0.020 r = -0.634 and p = 0.010 r = -0.683, respectively) in the IPAH group. There were also moderate correlations of FEF 25-75 % with Z5 (p = 0.041), R5 (p = 0.018), Fres (p = 0.043) and AX (p = 0.023). DISCUSSION: Patients showed changes suggestive of increased resistance and reactance in the IOS compared to healthy individuals, and the IOS findings showed a good correlation with spirometry variables.


Assuntos
Hipertensão Arterial Pulmonar , Humanos , Oscilometria/métodos , Volume Expiratório Forçado , Testes de Função Respiratória/métodos , Pulmão , Espirometria
10.
Artigo em Inglês | MEDLINE | ID: mdl-38464561

RESUMO

Purpose: Chronic obstructive pulmonary disease (COPD) phenotypes may introduce different characteristics that need to be known to improve treatment. Respiratory oscillometry provides a detailed analysis and may offer insight into the pathophysiology of COPD. In this paper, we used this method to evaluate the differences in respiratory mechanics of COPD phenotypes. Patients and Methods: This study investigated a sample of 83 volunteers, being divided into control group (CG = 20), emphysema (n = 23), CB (n = 20) and asthma-COPD overlap syndrome (ACOS, n = 20). These analyses were performed before and after bronchodilator (BD) use. Functional capacity was evaluated using the Glittre­ADL test, handgrip strength and respiratory pressures. Results: Initially it was observed that oscillometry provided a detailed description of the COPD phenotypes, which was consistent with the involved pathophysiology. A correlation between oscillometry and functional capacity was observed (r=-0.541; p = 0.0001), particularly in the emphysema phenotype (r = -0.496, p = 0.031). BD response was different among the studied phenotypes. This resulted in an accurate discrimination of ACOS from CB [area under the receiver operating curve (AUC) = 0.84] and emphysema (AUC = 0.82). Conclusion: These results offer evidence that oscillatory indices may enhance the comprehension and identification of COPD phenotypes, thereby potentially improving the support provided to these patients.


Assuntos
Asma , Enfisema , Doença Pulmonar Obstrutiva Crônica , Enfisema Pulmonar , Humanos , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Pulmão , Oscilometria/métodos , Força da Mão , Volume Expiratório Forçado , Broncodilatadores/uso terapêutico , Fenótipo , Desempenho Físico Funcional
11.
J Clin Hypertens (Greenwich) ; 26(5): 532-542, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38552166

RESUMO

This study evaluated an oscillometric device (OD), Microlife WatchBP Office AFIB, and a hybrid manual auscultatory device (AD), Greenlight 300TM, to determine a suitable blood pressure (BP) measurement device for the Korea National Health and Nutrition Examination Survey in a mercury-free context. Adhering to the 2018 Universal Standard's suggested consensus, the study involved 800 subjects (mean age 51.2 ± 17.5 years; 44.3% male), who underwent triplicate BP measurements following 5 min of rest in a randomized order (OD-first: 398 participants; AD-first: 402 participants). BP difference was calculated as OD value minus AD value, with results stratified by measurement sequence. The overall BP difference and tolerable error probability were -1.1 ± 6.5/-2.6 ± 4.9 mmHg and 89.2%/92.5% for systolic/diastolic BP (SBP/DBP), respectively. Lin's concordance correlation coefficient was 0.907/0.844 for SBP/DBP (OD-first/AD-first: 0.925/0.892 for SBP, 0.842/0.845 for DBP). The overall agreement for hypertension (BP ≥ 140 and/or 90 mmHg) was 0.71 (p < 0.0001), and the OD underestimated the overall hypertension prevalence by 5.1%. Analysis of the AD-first data revealed a lower level of agreement compared to the OD-first data; however, the observed blood pressure difference adhered to Criterion 1 of the 2018 Universal Standard. Microlife met the Criterion 1 of 2018 Universal Standard but underestimated the prevalence of hypertension. The BP discrepancy increased with higher BP levels, male sex, and smaller AC. With increasing age, the discrepancy decreased for SBP and increased for DBP.


Assuntos
Auscultação , Determinação da Pressão Arterial , Inquéritos Nutricionais , Oscilometria , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , República da Coreia/epidemiologia , Inquéritos Nutricionais/métodos , Determinação da Pressão Arterial/métodos , Determinação da Pressão Arterial/instrumentação , Determinação da Pressão Arterial/estatística & dados numéricos , Adulto , Oscilometria/instrumentação , Oscilometria/métodos , Idoso , Auscultação/métodos , Auscultação/instrumentação , Hipertensão/diagnóstico , Hipertensão/epidemiologia , Hipertensão/fisiopatologia , Pressão Sanguínea/fisiologia , Reprodutibilidade dos Testes
12.
Pediatr Pulmonol ; 59(5): 1321-1329, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38353391

RESUMO

BACKGROUND: In preschoolers, performing an acceptable spirometry and measuring bronchodilator response (BDR) is challenging; in this context, impulse oscillometry (IOS) represents a valid alternative. However, more studies on the standardization of BDR for IOS in young children are required. OBJECTIVE: The objective of the study was to identify optimal thresholds to define a positive BDR test with IOS in preschoolers with suspected asthma. METHODS: Children aged 3-6 years with suspected asthma and their lung function investigated with both IOS and spirometry pre- and post-BDR were retrospectively analyzed. The spirometric BDR was defined as positive when the change of FEV1 was ≥12% or ≥200 mL. The oscillometric BDR was defined as positive in case of change of at least -40% in R5, +50% in X5, and -80% in AX. RESULTS: Among 72 patients, 36 (age 5.2 ± 1 years; 64% boys) were selected for the subsequent analysis according to ATS/ERS quality criteria of measurements; specifically, 19 patients did not meet IOS and 36 did not meet spirometry criteria. The spirometric BDR was found positive in seven subjects (19.4%); conversely, a positive oscillometric BDR was identified in four patients (11.1%). No patient presented a positive BDR response with both methods. In IOS, the mean decrease in R5 and AX was 19.9% ± 10% and 44% ± 22.1%, and the mean increase in X5 was 23.3% ± 17.8%, respectively. A decrease in R5 of 25.7% (AUC 0.77, p = .03) and an increase in X5 of 25.7% (AUC 0.75, p = .04) showed the best combination of sensitivity and specificity to detect an increase of FEV1 ≥ 12% and/or ≥200 mL. CONCLUSION: The IOS represents a valid alternative to spirometry to measure BDR in preschool children and should be the gold standard in this age group. We are considering a decrease of 26% in R5 and an increase of 26% in X5 as diagnostic threshold for BDR.


Assuntos
Asma , Broncodilatadores , Oscilometria , Espirometria , Humanos , Oscilometria/métodos , Feminino , Masculino , Pré-Escolar , Espirometria/métodos , Estudos Retrospectivos , Criança , Asma/diagnóstico , Asma/fisiopatologia , Asma/tratamento farmacológico , Volume Expiratório Forçado
13.
Respir Med ; 224: 107564, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38360190

RESUMO

BACKGROUND: Impulse oscillometry (IOS) is an effective tool for assessing airway mechanics and diagnosing obstructive airway disease (OAD) in children with sickle cell disease (C-SCD). Obesity is known to be associated with OAD, and untreated OAD often leads to hypoxia-related complications in C-SCD. Considering the increasing prevalence of obesity in C-SCD, it is important to explore the influence of body mass index (BMI) on OAD in this disease population. METHODS: A longitudinal retrospective chart review was conducted on 55 C-SCD (161 IOS observations) and 35 non-SCD asthmatic children (C-Asthma) (58 observations), primarily to investigate the association between BMI and airway resistance in C-SCD and C-Asthma. We conducted generalized linear mixed models (GLMM), adjusted for pharmacotherapies, to demonstrate the influence of BMI on total (R5), central (R20), and peripheral (R5-20) airway resistance and reactance (X5, resonant frequency (Fres)). We further compared age, BMI, and IOS indices between C-SCD and C-Asthma using the Mann-Whitney test. RESULTS: Age and BMI were not statistically different between the two groups. In C-SCD, BMI was associated with R5 (GLMM t-statistics:3.75, 95%CI:1.01,3.27, p-value<0.001*) and R20 (t-statistics:4.01, 95%CI:1.04,1.15, p-value<0.001*), but not with R5-20 or airway reactance. In asthmatics, BMI was not associated with IOS estimates except Fres (t-statistics: 3.93, 95%CI: -0.06, -0.02, p-value<0.001*). C-SCD demonstrated higher airway resistances (R5 and R20) and reactance (Fres) compared to C-Asthma (Mann-Whitney: p-values<0.05). CONCLUSION: BMI significantly influenced total and central airway resistance in C-SCD. While higher airway resistances reflected increased OAD in C-SCD than asthmatics, higher Fres perhaps indicated progressive pulmonary involvement in C-SCD.


Assuntos
Anemia Falciforme , Asma , Criança , Humanos , Resistência das Vias Respiratórias , Índice de Massa Corporal , Estudos Retrospectivos , Estudos Longitudinais , Oscilometria , Espirometria , Pulmão , Asma/tratamento farmacológico , Anemia Falciforme/complicações , Obesidade
14.
Pediatr Pulmonol ; 59(5): 1394-1401, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38390766

RESUMO

OBJECTIVE: While coronavirus disease 2019 (COVID-19) is generally considered to exhibit a less severe clinical course in children than in adults, studies have demonstrated that respiratory symptoms can endure for more than 3 months following infection in at least one-third of pediatric cases. The present study evaluates the respiratory functions of children aged 3-15 years within 3-6 months of their recovery from COVID-19 using impulse oscillometry (IOS) and compares them with the values of healthy children. METHODS: Included in this prospective cross-sectional study were 63 patients (patient group) aged 3-15 years who contracted COVID-19 between December 2021 and May 2022, as well as 57 healthy children as a control group, matched for age and sex. The demographic, clinical, and laboratory data of the patients were recorded, and respiratory function was assessed based on airway resistance (zR5, zR20, R5-20) and reactance (zX5, zX20, reactance area [AX], resonant frequency [Fres]) using an IOS device. RESULTS: There were no significant differences in the age, weight, height, and body weight z score values of the two groups (p > .05). While the zR5 and R5-20 levels of the patient group were higher (p = .008 and p < .001, respectively) than those of the controls, the zR20, AX, and Fres values did not differ significantly between the groups (p > .05). The parameters indicating the reactance, including zX5 and zX20, were significantly lower in the patient group than in the control group (p = .028 and p < .001, respectively). CONCLUSION: Total and peripheral airway resistances were found to be elevated in children who had recovered from COVID-19 in the preceding 3-6 months.


Assuntos
COVID-19 , Oscilometria , Testes de Função Respiratória , SARS-CoV-2 , Humanos , Criança , COVID-19/fisiopatologia , COVID-19/complicações , COVID-19/diagnóstico , Masculino , Feminino , Adolescente , Pré-Escolar , Estudos Transversais , Oscilometria/métodos , Estudos Prospectivos , Testes de Função Respiratória/métodos , Estudos de Casos e Controles , Resistência das Vias Respiratórias/fisiologia , Pandemias , Pneumonia Viral/fisiopatologia , Pneumonia Viral/diagnóstico , Betacoronavirus
15.
Sci Rep ; 14(1): 4644, 2024 02 26.
Artigo em Inglês | MEDLINE | ID: mdl-38409397

RESUMO

Airborne transmission of pathogens plays a major role in the spread of infectious diseases. Aerosol particle production from the lung is thought to occur in the peripheral airways. In the present study we investigated eighty lung-healthy subjects of two age groups (20-39, 60-76 years) at rest and during exercise whether lung function parameters indicative of peripheral airway function were correlated with individual differences in aerosol particle emission. Lung function comprised spirometry and impulse oscillometry during quiet breathing and an expiratory vital capacity manoeuvre, using resistance (R5) and reactance at 5 Hz (X5) as indicators potentially related to peripheral airway function. The association between emission at different ventilation rates relative to maximum ventilation and lung function was assessed by regression analysis. In multiple regression analyses including age group, only vital capacity manoeuvre R5 at 15% to 50% of end-expiratory vital capacity as well as quiet breathing X5 were independently linked to particle emission at 20% to 50% of maximum ventilation, in addition to age group. The fact that age as predictive factor was still significant, although to a lower degree, points towards further effects of age, potentially involving surface properties not accounted for by impulse oscillometry parameters.


Assuntos
Resistência das Vias Respiratórias , Pulmão , Humanos , Adulto Jovem , Adulto , Oscilometria , Testes de Função Respiratória , Espirometria , Volume Expiratório Forçado
16.
Curr Opin Pulm Med ; 30(3): 268-275, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38411171

RESUMO

PURPOSE OF REVIEW: Oscillometry is a noninvasive pulmonary function test that has gained significant interest in the evaluation of lung disease. Currently, oscillometry is primarily a research tool, but there is a growing body of evidence supporting its clinical use. This review describes the recent work evaluating the role of oscillometry in the diagnosis and treatment of asthma. RECENT FINDINGS: A large body of observational data supports the ability of oscillometry to distinguish healthy individuals from those with respiratory symptoms or lung disease. Oscillometry may not be as useful as an isolated diagnostic test in asthma, but the combination with other pulmonary function tests may improve its diagnostic ability. Oscillometry can detect peripheral airways dysfunction in asthma, which is associated with symptoms and the risk for exacerbations. To help guide future research, minimal clinically important differences for specific oscillometry variables have been developed. Oscillometry may be useful in monitoring the response to biological therapy and has potential for personalizing treatment for individual patients. Oscillometry also has potential in uncovering unique aspects of the pathophysiology of asthma in obesity. SUMMARY: Oscillometry is a promising tool in the diagnosis and management of asthma. More research is needed to support its routine clinical use.


Assuntos
Asma , Pneumopatias , Humanos , Pulmão , Oscilometria , Espirometria , Asma/tratamento farmacológico
19.
Chest ; 165(2): e27-e31, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38336440

RESUMO

Irritant-induced asthma (IIA) may develop after acute inhalational exposure in individuals without preexisting asthma. The effect of bronchial thermoplasty to treat intractable, worsening IIA has not yet been described. We evaluated a previously healthy 52-year-old man after inhalation of an unknown white powder. His pulmonary function and symptoms/quality of life worsened over 4 years, despite maximal guidelines-based asthma therapy. We acquired 129Xe MRI and pulmonary function test measurements on three occasions including before and after bronchial thermoplasty treatment. Seven months after bronchial thermoplasty, improved MRI ventilation and oscillometry small airway resistance were observed. Spirometry and asthma control did not improve until 19 months after bronchial thermoplasty, 5.5 years postexposure. Together, oscillometry measurements of the small airways and 129Xe MRI provided effort-independent, sensitive, and objective measurements of response to therapy. Improved MRI and oscillometry small airway resistance measurements temporally preceded improved airflow obstruction and may be considered for complex asthma cases.


Assuntos
Asma , Termoplastia Brônquica , Masculino , Humanos , Pessoa de Meia-Idade , Termoplastia Brônquica/efeitos adversos , Irritantes , Qualidade de Vida , Oscilometria , Imageamento por Ressonância Magnética
20.
Respir Care ; 69(4): 415-421, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38167212

RESUMO

BACKGROUND: Impulse oscillometry (IOS) is a noninvasive technique that measures lung physiology independently of patient effort. In the present study, we aimed to investigate the utility of IOS parameters in comparison with pulmonary function testing (PFT) among hospitalized subjects, with emphasis on obstructive and small airway diseases. METHODS: Sixty-one subjects hospitalized either with unexplained dyspnea or for pre-surgery evaluation were included in the study. All subjects underwent PFTs and IOS test. The correlation between IOS results and PFTs was examined in different subgroups. The ability of IOS parameters to predict abnormal PFTs was evaluated using the area under the receiver operating characteristic (ROC) curve, and optimal cutoff values were calculated. RESULTS: IOS results were found to correlate with PFT values. Subgroup analysis revealed that these correlations were higher in younger (age < 70) and non-obese (body mass index < 25kg/m2) subjects. The resonant frequency was an independent predictor and had the best predictive ability for abnormal FEV1/FVC (area under the ROC curve 0.732 [95% CI 0.57-0.90], optimal cutoff 17 Hz, 87% sensitivity, 62% specificity) and abnormal forced expiratory flow during the middle half of the FVC maneuver (area under the ROC curve 0.667 [95% CI 0.53-0.81], optimal cutoff 15 Hz, 77% sensitivity, 54% specificity). Area of reactance and the difference in respiratory resistance at 5 Hz and 20 Hz also showed a good predictive ability for abnormal FEV1/FVC (area under the ROC curve 0.716 and 0.730, respectively). CONCLUSIONS: We found that the IOS performed well in diagnosing small airway and obstructive diseases among hospitalized subjects. IOS might serve as an alternative to standard PFTs in non-cooperative or dyspneic hospitalized patients.


Assuntos
Asma , Doença Pulmonar Obstrutiva Crônica , Adulto , Humanos , Oscilometria/métodos , Espirometria , Testes de Função Respiratória/métodos , Dispneia , Volume Expiratório Forçado