1.
Am J Pharm Educ ; 77(3): 58, 2013 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-23610476

RESUMO

OBJECTIVE. To assess the effectiveness of using a vapor pressure osmometer to measure the accuracy of pharmacy students' compounding skills. DESIGN. Students calculated the theoretical osmotic pressure (mmol/kg) of a solution as a pre-laboratory exercise, compared their calculations with actual values, and then attempted to determine the cause of any errors found. ASSESSMENT. After the introduction of the vapor pressure osmometer, the first-time pass rate for solution compounding has varied from 85% to 100%. Approximately 85% of students surveyed reported that the instrument was valuable as a teaching tool because it objectively assessed their work and provided immediate formative assessment. CONCLUSIONS. This simple technique of measuring compounding accuracy using a vapor pressure osmometer allowed students to see the importance of quality control and assessment in practice for both pharmacists and technicians.


Assuntos
Currículo/normas , Avaliação Educacional/normas , Osmometria/normas , Soluções Farmacêuticas/normas , Estudantes de Farmácia , Pressão de Vapor , Avaliação Educacional/métodos , Humanos , Pressão Osmótica , Soluções Farmacêuticas/síntese química
2.
Graefes Arch Clin Exp Ophthalmol ; 250(8): 1201-5, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22350061

RESUMO

BACKGROUND: Some studies report that increased tear osmolarity is a reliable indicator of dry eye syndrome (DES). The OcuSense TearLab™ osmometer requires less than a 100-nl sample of tears and provides an instant quantitative result. Our aim was to clinically evaluate this instrument in terms of its reproducibility and repeatability. METHODS: Twenty-nine participants who ranged in age from 19 to 49 years (mean ± SD: 23.3 ± 5.5 years) were recruited. Osmolarity readings were collected by two operators, in two sessions separated by 1 or 2 weeks in order to assess test reproducibility and repeatability. RESULTS: The coefficient of reproducibility was 39 mOsms/l; the coefficient of repeatability was 33 mOsms/l. CONCLUSIONS: Our mean coefficient of variation over four readings for 29 subjects is 2.9%, which compares well with that reported by the manufacturer. Our results inform practitioners about the level of change over time that can be considered clinically relevant for healthy subjects. This value is 33mOsms/l; any change smaller than this could be attributed to measurement noise.


Assuntos
Técnicas de Diagnóstico Oftalmológico/normas , Osmometria/normas , Lágrimas/química , Adulto , Técnicas de Diagnóstico Oftalmológico/instrumentação , Síndromes do Olho Seco/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Concentração Osmolar , Osmometria/instrumentação , Reprodutibilidade dos Testes , Adulto Jovem