J Plast Surg Hand Surg ; 59: 46-52, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38747532

RESUMO

Standard volar plates often do not fit the surface of the malunited distal radius after osteotomy, necessitating an offset angle for accurate volar tilt correction. The correction can be achieved if the plate is held at the correct angle when the distal screws are locked. With the advantage of 3D surgical planning and patient-specific instruments, we developed a shim instrument to assist the surgeon in securing the plate at the intended angle when locking the distal screws, and evaluated radiological results. Five female patients aged 63-74 with dorsally angulated extra-articular malunions underwent surgery using 3D-printed guides and the shim instrument. The plate position, drilling guide alignment, screw placements, and distal radius correction on postoperative CTs were compared with the surgical plans. Errors were measured using an anatomical coordinate system, and standard 2D radiographic measures were extracted. Preoperative dorsal tilt ranged from 16° to 35°, and postoperative volar tilt from 1° to 11°. 3D analysis revealed mean absolute correction errors of 6.1° in volar tilt, 1.6° in radial inclination, and 0.6 mm in ulnar variance. The volar tilt error due to the shim instrument, indicated by the mean angle error of the distal screws to the plate, was 2.1° but varied across the five patients. Settling of the distal radius, due to tension during and after reduction, further contributed to a mean loss of 3.5° in volar tilt. The shim instrument helped with securing plates at the intended angle; however, further correction improvements should consider the tension between the fragments of osteoporotic bone.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas , Fraturas Mal-Unidas , Osteotomia , Fraturas do Rádio , Humanos , Feminino , Osteotomia/métodos , Osteotomia/instrumentação , Pessoa de Meia-Idade , Fraturas do Rádio/cirurgia , Fraturas do Rádio/diagnóstico por imagem , Idoso , Fraturas Mal-Unidas/cirurgia , Fraturas Mal-Unidas/diagnóstico por imagem , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Impressão Tridimensional , Cirurgia Assistida por Computador , Imageamento Tridimensional , Parafusos Ósseos , Tomografia Computadorizada por Raios X
2.
Jt Dis Relat Surg ; 35(2): 439-442, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38727126

RESUMO

Tension band wiring (TBW) is one of the most commonly used fixation techniques to fix olecranon osteotomies. Hardware prominence has been the most commonly reported complication of TBW. However, distal migration of Kirschner (K)-wire after TBW fixation for olecranon osteotomy has not been reported. In this case report, we presented distal migration of K-wire detected nine months after initial surgery in a 46-year-old male patient. The patient was operated on for an intraarticular distal humerus fracture using an olecranon osteotomy. The osteotomy was fixed with TBW fixation. The patient missed routine follow-ups and presented to the outpatient clinic with a complaint of skin irritation at the elbow nine months after the surgery. On radiological examination, distal migration of one K-wire was detected. The K-wire was surgically removed without any complication. Physicians should be aware of possible complications of TBW and remove fixation after fracture union to avoid unexpected complications.


Assuntos
Fios Ortopédicos , Migração de Corpo Estranho , Olécrano , Osteotomia , Humanos , Fios Ortopédicos/efeitos adversos , Masculino , Pessoa de Meia-Idade , Olécrano/lesões , Olécrano/cirurgia , Olécrano/diagnóstico por imagem , Osteotomia/efeitos adversos , Osteotomia/métodos , Osteotomia/instrumentação , Migração de Corpo Estranho/cirurgia , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Fraturas do Úmero/cirurgia , Fraturas do Úmero/diagnóstico por imagem , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Remoção de Dispositivo/métodos , Articulação do Cotovelo/cirurgia , Articulação do Cotovelo/diagnóstico por imagem , Fraturas Intra-Articulares/cirurgia , Fraturas Intra-Articulares/diagnóstico por imagem
3.
J Dent ; 145: 105017, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38657725

RESUMO

OBJECTIVES: This observational study aimed to evaluate the accuracy of robotic computer-assisted implant surgery (r-CAIS) for full-arch immediate restoration and to analyse possible factors contributing to deviations. METHODS: Three edentulous patients (five arches) underwent r-CAIS. Osteotomies were performed using an autonomous robot under the surgeon's supervision, and implant placement was performed in a freehand or robotic manner. Prefabricated provisional prostheses were delivered immediately after surgery. Postoperative cone beam computed tomography scans were performed to assess the deviations between the planned and placed implants. Statistics were compared with deviations of s-CAIS outlined in a meta-analysis. RESULTS: A sum of 28 implants were used. The mean global coronal and apical deviations measured 0.91 ± 0.43 mm and 1.01 ± 0.45 mm, respectively, and the mean angular deviation measured 1.21 ± 1.24 º. The r-CAIS showed significantly better precision than the s-CAIS in full-arch cases (P < 0.001). The implants inserted using the robotic arm exhibited fewer deviations than those placed in the freehand manner. Eighty percent of prefabricated provisional prostheses were successfully delivered. CONCLUSIONS: Within the limitations of the present study, our data suggest that autonomous r-CAIS is a feasible approach for simultaneous immediate restoration in edentulous patients, showing better accuracy than s-CAIS. Further large-scale studies are necessary to verify the advantages and disadvantages of this novel technique and to explore possible factors that influence its accuracy. CLINICAL SIGNIFICANCE: Autonomous r-CAIS can provide clinically acceptable implant placement accuracy in edentulous patients, significantly surpassing s-CAIS. This level of accuracy may represent a viable therapeutic approach for simultaneous immediate full-arch restoration.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea , Implantes Dentários , Cirurgia Assistida por Computador , Humanos , Masculino , Feminino , Cirurgia Assistida por Computador/métodos , Implantação Dentária Endóssea/métodos , Pessoa de Meia-Idade , Idoso , Carga Imediata em Implante Dentário/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Prótese Dentária Fixada por Implante , Arcada Edêntula/cirurgia , Arcada Edêntula/diagnóstico por imagem , Arcada Edêntula/reabilitação , Osteotomia/métodos , Osteotomia/instrumentação , Resultado do Tratamento , Maxila/cirurgia , Maxila/diagnóstico por imagem
4.
Sci Rep ; 14(1): 9475, 2024 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658572

RESUMO

The Periacetabular Osteotomy is a technically demanding procedure that requires precise intraoperative evaluation of pelvic anatomy. Fluoroscopic images pose a radiation risk to operating room staff, scrubbed personnel, and the patient. Most commonly, a Standard Fluoroscope with an Image Intensifier is used. Our institution recently implemented the novel Fluoroscope with a Flat Panel Detector. The purpose of this study was to compare radiation dosage and accuracy between the two fluoroscopes. A retrospective review of a consecutive series of patients who underwent Periacetabular Osteotomy for symptomatic hip dysplasia was completed. The total radiation exposure dose (mGy) was recorded and compared for each case from the standard fluoroscope (n = 27) and the flat panel detector (n = 26) cohorts. Lateral center edge angle was measured and compared intraoperatively and at the six-week postoperative visit. A total of 53 patients (96% female) with a mean age and BMI of 17.84 (± 6.84) years and 22.66 (± 4.49) kg/m2 (standard fluoroscope) and 18.23 (± 4.21) years and 21.99 (± 4.00) kg/m2 (flat panel detector) were included. The standard fluoroscope averaged total radiation exposure to be 410.61(± 193.02) mGy, while the flat panel detector averaged 91.12 (± 49.64) mGy (p < 0.0001). The average difference (bias) between intraoperative and 6-week postoperative lateral center edge angle measurement was 0.36° (limits of agreement: - 3.19 to 2.47°) for the standard fluoroscope and 0.27° (limits of agreement: - 2.05 to 2.59°) for the flat panel detector cohort. Use of fluoroscopy with flat panel detector technology decreased the total radiation dose exposure intraoperatively and produced an equivalent assessment of intraoperative lateral center edge angle. Decreasing radiation exposure to young patients is imperative to reduce the risk of future comorbidities.


Assuntos
Osteotomia , Doses de Radiação , Exposição à Radiação , Humanos , Fluoroscopia/métodos , Feminino , Masculino , Exposição à Radiação/prevenção & controle , Estudos Retrospectivos , Osteotomia/instrumentação , Osteotomia/métodos , Adolescente , Adulto Jovem , Acetábulo/cirurgia , Acetábulo/diagnóstico por imagem , Adulto , Luxação do Quadril/prevenção & controle , Luxação do Quadril/diagnóstico por imagem , Luxação do Quadril/etiologia , Criança
5.
Eur J Orthop Surg Traumatol ; 34(4): 1865-1870, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38431895

RESUMO

PURPOSE: Tarsal tunnel syndrome is well documented following lateralizing calcaneal osteotomy to manage varus hindfoot deformity. Traditionally, calcaneal osteotomy is performed with an oscillating saw. No studies have investigated the effect of alternative surgical techniques on postoperative tarsal tunnel pressure. The purpose of this study was to investigate the difference in tarsal tunnel pressures following lateralizing calcaneal osteotomy performed using a high-torque, low-speed "minimally invasive surgery" (MIS) Shannon burr versus an oscillating saw. METHODS: Lateralizing calcaneal osteotomy was performed on 10 below-knee cadaveric specimens. This was conducted on 5 specimens each using an oscillating saw (Saw group) or MIS burr (Burr group). The calcaneal tuberosity was translated 1 cm laterally and transfixed using 2 Kirschner wires. Tarsal tunnel pressure was measured before and after osteotomy via ultrasound-guided percutaneous needle barometer. Mean pre/post-osteotomy pressures were compared between groups. Differences were analyzed using Student's t test. RESULTS: The mean pre-procedure tarsal tunnel pressure was 25.8 ± 5.1 mm Hg in the Saw group and 26.4 ± 4.3 mm Hg in the Burr group (p = 0.85). The mean post-procedure pressure was 63.4 ± 5.1 in the Saw group and 47.8 ± 4.3 in the Burr group (p = 0.01). Change in tarsal tunnel pressure was significantly lower in the Burr group (21.4 ± 4.5) compared to the Saw group (37.6 ± 12.5) (p = 0.03). The increase in tarsal tunnel pressure was 43% lower in the Burr group. CONCLUSION: In this cadaveric study, tarsal tunnel pressure increase after lateralizing calcaneal osteotomy was significantly lower when using a burr versus a saw. This is likely because the increased width ("kerf") of the 3 mm MIS burr, compared to the submillimeter saw blade width, causes calcaneal shortening. Given the smaller increase in tarsal tunnel pressure, using the MIS burr for lateralizing calcaneal osteotomy may decrease the risk of postoperative tarsal tunnel syndrome. Future research in vivo should explore this.


Assuntos
Cadáver , Calcâneo , Osteotomia , Pressão , Síndrome do Túnel do Tarso , Humanos , Osteotomia/métodos , Osteotomia/instrumentação , Calcâneo/cirurgia , Síndrome do Túnel do Tarso/cirurgia , Síndrome do Túnel do Tarso/etiologia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Masculino , Feminino , Idoso
6.
World Neurosurg ; 185: e387-e396, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38350596

RESUMO

BACKGROUND: Spinal decompression and osteotomies are conventionally performed using high-speed drills (HSDs) and rongeurs. The ultrasonic bone scalpel (UBS) is a tissue-specific osteotome that preferentially cuts bone while sparing the surrounding soft tissues. There is ongoing investigation into its ability to optimize peri- and postoperative outcomes in spine surgery. The purpose of this study was to compare the intraoperative metrics and complications during a transition period from HSD to UBS. METHODS: A single-institution, single-surgeon retrospective analysis was conducted of patients undergoing spine surgery from January 2020 to December 2021. Statistical analyses were performed to detect associations between the surgical technique and outcomes of interest. A P value < 0.05 was considered statistically significant. RESULTS: A total of 193 patients met the inclusion criteria (HSD, n = 100; UBS, n = 93). Multivariate logistic regression revealed similar durotomy (P = 0.10), nerve injury (P = 0.20), and reoperation (P = 0.68) rates. Although the estimated blood loss (EBL) and length of stay were similar, the operative time was significantly longer with the UBS (192.81 vs. 204.72 minutes; P = 0.03). Each subsequent surgery using the UBS revealed a 3.1% decrease in the probability of nerve injury (P = 0.026) but had no significant effects on the operative time, EBL, or probability of durotomy or reoperation. CONCLUSIONS: The UBS achieves outcomes on par with conventional tools, with a trend toward a lower incidence of neurologic injury. The expected reductions in EBL and durotomy were not realized in our cohort, perhaps because of a high proportion of revision surgeries, although these might be dependent on surgeon familiarity, among other operative factors. Future prospective studies are needed to validate our results and further refine the optimal application of this device in spine surgery.


Assuntos
Osteotomia , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Osteotomia/métodos , Osteotomia/instrumentação , Idoso , Duração da Cirurgia , Adulto , Procedimentos Cirúrgicos Ultrassônicos/instrumentação , Procedimentos Cirúrgicos Ultrassônicos/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Descompressão Cirúrgica/métodos , Descompressão Cirúrgica/instrumentação , Instrumentos Cirúrgicos , Perda Sanguínea Cirúrgica
7.
J Endod ; 50(6): 859-864, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38369101

RESUMO

INTRODUCTION: Endodontic microsurgery (EMS) requires minimally invasive osteotomy and accurate root-end resection, which can be challenging in many instances. Evidence suggests that autonomous robotic systems can significantly enhance the precision of dental implantation. The aim of this case report is to introduce a novel EMS technique that employs robot-guided osteotomy and root resection procedures. METHODS: A 59-year-old man was diagnosed with previously treated, symptomatic apical periodontitis in the mandibular left first molar. Patient data were used to integrate a digital model into preoperative planning software to design the surgical plan. The robotic system utilizes spatial alignment techniques for registration, guiding the robotic arm to autonomously perform a 3-mm osteotomy and root-end resection, based on the surgical plan. After completing the resection, the clinician confirmed the absence of cracks or root fractures and subsequently performed root-end preparation and filling under a microscope. RESULTS: To the best of our knowledge, this case marks the first use of autonomous robotic assistance in EMS. CONCLUSIONS: Utilizing an autonomous robotic system could enable precise apicoectomy in patients with intact cortical plates, thus facilitating successful EMS procedures. This has the potential to minimize errors caused by operator inexperience and mitigate the risks associated with excessive bone removal.


Assuntos
Microcirurgia , Periodontite Periapical , Procedimentos Cirúrgicos Robóticos , Humanos , Masculino , Pessoa de Meia-Idade , Microcirurgia/instrumentação , Microcirurgia/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Periodontite Periapical/cirurgia , Osteotomia/métodos , Osteotomia/instrumentação , Apicectomia/métodos , Dente Molar/cirurgia
8.
Vet Surg ; 53(2): 234-242, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37309843

RESUMO

OBJECTIVE: To compare the accuracy of three-dimensional (3D) printed patient-specific guide (PSG) with a freehand (FH) approach for radial osteotomies in ex vivo normal dogs. STUDY DESIGN: Experimental study. ANIMALS: Twenty four ex vivo thoracic limb pairs from normal beagle dogs. METHODS: Computed tomography (CT) images were collected preoperatively and postoperatively. Three osteotomies tested (n = 8/group) were: (1) uniplanar 30° frontal plane wedge ostectomy, (2) oblique plane (30° frontal, 15° sagittal) wedge ostectomy, and (3) single oblique plane osteotomy (SOO, 30° frontal, 15° sagittal, and 30° external). Limb pairs were randomized to a 3D PSG or FH approach. The resultant osteotomies were compared with virtual target osteotomies by surface shape-matching postoperative to the preoperative radii. RESULTS: The mean ± standard deviation osteotomy angle deviation for all 3D PSG osteotomies (2.8 ± 2.8°, range 0.11-14.1°) was less than for the FH osteotomies (6.4 ± 6.0°, range 0.03-29.7°). No differences were found for osteotomy location in any group. In total, 84% of 3D PSG osteotomies were within 5° deviance from the target compared to 50% of freehand osteotomies. CONCLUSION: Three-dimensional PSG improved FH accuracy of osteotomy angle in select planes and the most complex osteotomy orientation in a normal ex vivo radial model. CLINICAL SIGNIFICANCE: Three-dimensional PSGs provided more consistent accuracy, which was most notable in complex radial osteotomies. Future work is needed to investigate guided osteotomies in dogs with antebrachial bone deformities.


Assuntos
Osteotomia , Rádio (Anatomia) , Animais , Cães , Membro Anterior/cirurgia , Imageamento Tridimensional , Osteotomia/instrumentação , Osteotomia/métodos , Osteotomia/veterinária , Impressão Tridimensional , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/cirurgia , Tomografia Computadorizada por Raios X/veterinária , Distribuição Aleatória
9.
Sensors (Basel) ; 23(4)2023 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-36850902

RESUMO

Osteotomies are common procedures in maxillofacial and orthopedic surgery. The surgeons still rely on their proprioception to control the progression of the osteotome. Our group has developed an instrumented hammer that was shown to provide information on the biomechanical properties of the tissue located around the osteotome tip. The objective of this study is to determine if this approach may be used to predict the rupture of a bone sample thanks to an instrumented hammer equipped with a force sensor. For each impact, an indicator τ is extracted from the signal corresponding to the variation of the force as a function of time. A linear by part regression analysis is applied to the curve corresponding to the variation of τ as a function of the distance d between the tip of the osteotome and the end of the sample. The experiments were conducted with plywood and bovine trabecular bone samples. The results show that τ starts increasing when the value of d is lower than 2.6 mm on average, which therefore corresponds to a typical threshold detection distance between the osteotome tip and the sample end. These findings open new paths for the development of this instrumented surgical hammer.


Assuntos
Osso Esponjoso , Ortopedia , Osteotomia , Equipamentos Cirúrgicos , Animais , Bovinos , Osteotomia/instrumentação , Propriocepção
10.
Rev. cuba. ortop. traumatol ; 36(2): e567, abr.-jun. 2022. ilus, tab
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1409055

RESUMO

Introducción: En pocas áreas de la cirugía ortopédica se han producido cambios técnicos tan importantes en las últimas décadas como en la cirugía correctora espinal. Los cambios fundamentales han sobrevenido con los nuevos sistemas de instrumentación espinal, que se han modificado y mejorado sustancialmente para facilitar la corrección tridimensional de la deformidad y aportar fijación segura de la columna, corrección y estabilidad. Objetivo: Evaluar los resultados alcanzados con los sistemas de instrumentación espinal utilizados en la corrección de la cifosis toracolumbar por espondilitis anquilopoyética. Método: Se realizó un estudio tipo descriptivo, retrospectivo y longitudinal a 16 pacientes con cifosis toracolumbar por espondilitis anquilopoyética intervenidos con la técnica de osteotomía de sustracción pedicular e instrumentados con sistemas pediculares y sublaminar tipo Luque, en el servicio de Ortopedia del Hospital Clínico Quirúrgico Hermanos Ameijeiras, durante el período comprendido entre marzo de 2001 y marzo de 2021. Resultados: La totalidad de los pacientes correspondieron al sexo masculino, color de la piel blanca y edad promedio de 39 años. Se logró más del 80 por ciento de corrección en el perfil sagital y un promedio de 34,3° por osteotomía, sin complicaciones neurológicas mayores. Se obtuvo un buen resultado funcional, con un alto grado de satisfacción de los pacientes y mejora de su calidad de vida. Conclusiones: La utilización de ambos sistemas instrumentación espinal es eficaz para mantener la corrección de la cifosis toracolumbar por espondilitis anquilopoyética(AU)


Introduction: Few areas of orthopedic surgery have had such important technical changes in recent decades as in corrective spinal surgery. Fundamental changes have come with the new spinal instrumentation systems, which have been substantially modified and improved to facilitate three-dimensional correction of the deformity and provide secure spinal fixation, correction and stability. Objective: To evaluate the results achieved with the spinal instrumentation systems used in the correction of thoracolumbar kyphosis due to ankylosing spondylitis. Methods: A descriptive, retrospective and longitudinal study was carried out on 16 patients with thoracolumbar kyphosis due to ankylosing spondylitis operated on with the pedicle subtraction osteotomy technique and instrumented with Luque-type pedicle and sublaminar systems, in the Orthopedics service at Hermanos Ameijeiras Surgical Clinical Hospital, from March 2001 to March 2021. Results: All the patients were male, white skin color and average age of 39 years. More than 80 percent correction was achieved in the sagittal profile and an average of 34.3° per osteotomy, without major neurological complications. Good functional results were obtained, with high degree of patient satisfaction and improvement in their quality of life. Conclusions: The use of both spinal instrumentation systems is effective in maintaining the correction of thoracolumbar kyphosis due to ankylosing spondylitis(AU)


Assuntos
Humanos , Adulto , Pessoa de Meia-Idade , Osteotomia/instrumentação , Espondilite Anquilosante/cirurgia , Cifose/cirurgia , Epidemiologia Descritiva , Estudos Retrospectivos , Estudos Longitudinais
11.
PLoS One ; 17(2): e0261322, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35108280

RESUMO

Despite rigorous sterilization protocols placed in surgical procedures, there is demonstrated evidence that show patients contract infections while hospitalized. This study aims to investigate the presence of biological materials in osteotome surgical tools after sterilization processes, determine the relationship between lack of sharpness and cross-contamination, and evaluate the influence of materials surface coating as a potential contamination preventive. Three commercially available osteotomes with different surface coatings were studied and submitted to a procedure of bone-cutting cycles. After use, each was sterilized and examined under SEM and EDS. Bone contaminants were detected in each osteotome although the PVD coated osteotome demonstrated significantly less contamination than either the as-supplied or electroless nickel coated one. According to the results, there is an association between blade sharpness and post-sterilization bone contamination. These findings suggest either disposable osteotomes should be used in surgical procedures, or an effective sharpen process should both be established and monitored to minimise post-operative infections.


Assuntos
Infecção Hospitalar/etiologia , Instrumentos Cirúrgicos/efeitos adversos , Materiais Revestidos Biocompatíveis/química , Infecção Hospitalar/diagnóstico , Desenho de Equipamento , Humanos , Microscopia Eletrônica de Varredura , Osteotomia/instrumentação , Projetos Piloto , Propriedades de Superfície
12.
Ann R Coll Surg Engl ; 104(1): 53-56, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34323127

RESUMO

INTRODUCTION: Akin osteotomies are commonly fixed with a screw or staple. Hardware-related symptoms are not uncommon. We compared the outcomes and costs of the two implants. METHODS: We evaluated 74 Akin osteotomies performed in conjunction with first metatarsal osteotomy for hallux valgus. The osteotomy was fixed with a headless compression screw in 39 cases and a staple in 35 cases. We looked at the implant-related complications, removal of metalwork, revision, non-union and cost. Pre- and postoperative hallux valgus interphalangeal (HI) angles and length of the proximal phalanx were measured. RESULTS: There was 100% union, no failure of fixation, no revision surgery and no delayed union in either group. The radiological prominence of screws was significant (p=0.02), but there was no significant difference in soft-tissue irritation (p=0.36) or removal of implants (p=0.49). Two cortical breaches (5.8%) occurred in staple fixation and 4 (10.2%) in screw fixation (not statistically significant (NS), p=0.50). The mean improvement in HI angle was 4.3° with screw fixation and 4.1° with staple fixation (NS, p=0.69). The mean shortening of the proximal phalanx was 2.5mm with screw fixation and 2.3mm with staple fixation (NS, p=0.64). The total cost was £1,925 for staple fixation and £4,290 for screw fixation. CONCLUSIONS: Staple and screw fixation are reproducible modalities with satisfactory outcomes, but screw fixation is expensive. We conclude staple fixation is a cost-effective alternative.


Assuntos
Parafusos Ósseos , Hallux Valgus/cirurgia , Ossos do Metatarso/cirurgia , Osteotomia/instrumentação , Suturas , Parafusos Ósseos/economia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteotomia/economia , Estudos Retrospectivos , Suturas/economia
13.
PLoS One ; 16(10): e0257985, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34618848

RESUMO

OBJECTIVES: The aims of this study were to compare the initial implant stability obtained using four different osteotomy techniques in low-density synthetic bone, to evaluate the instrument design in comparison to the implant design, and to determinate a possible correlation between the insertion torque and initial stability quotient (ISQ). MATERIALS AND METHODS: Four groups were identified in accordance with the osteotomy technique used (n = 10 implants per group): group G1, osteotomy using the recommended drilling sequence; group G2, osteotomy using an undersized compactor drill; group G3, osteotomy using an undersized drill; and group G4, osteotomy using universal osseodensification drills. Two polyurethane blocks were used: block 1, with a medullary portion of 10 pounds per cubic foot (PCF 10) and with a 1 mm cortical portion of PCF 40, and block 2, with a medullary of PCF 15 and with a 2 mm cortical portion of PCF 40. Tapered implants of 4 mm in diameter and 11 mm in length were used. The insertion torque (IT) and ISQ were measured. The dimensions of the final instrument used in each group and the dimensions of the implant were used to calculate the total area of each part, and these data were compared. RESULTS: Differences between the four groups were found for IT and ISQ values depending on the technique used for the osteotomy in the two synthetic bone models (p < 0.0001). All groups showed lower values of initial stability in block 1 than in block 2. CONCLUSIONS: Undersized osteotomies with instruments designed according to the implant body significantly increased the initial stability values compared to beds prepared with universal drills and using the drilling sequence standardized by the manufacturer.


Assuntos
Osso e Ossos/cirurgia , Implantação Dentária Endóssea/instrumentação , Osteotomia/instrumentação , Próteses e Implantes , Densidade Óssea , Doenças Ósseas Metabólicas , Osso e Ossos/fisiopatologia , Brasil , Humanos , Projetos Piloto , Poliuretanos/química , Poliuretanos/uso terapêutico , Torque
14.
Sci Rep ; 11(1): 18834, 2021 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-34552116

RESUMO

The Distal Tibia Nail (DTN; Mizuho, Japan) has demonstrated higher biomechanical stiffness to locking plates in previous research for A3 distal tibia fractures. It is here investigated as a fixation option for supramalleolar corrective osteotomies (SMOT). Sixteen Sawbones tibiae were implanted with either a DTN (n = 8) or Medial Distal Tibia Plate (MDTP; n = 8) and a SMOT simulated. Two surgical outcome scenarios were envisaged: "best-case" representing an intact lateral cortex, and "worst-case" representing a fractured lateral cortex. All samples were subjected to compressive (350 N, 700 N) and torsional (± 4 Nm, ± 8 Nm) testing. Samples were evaluated using calculated construct stiffness from force-displacement data, interfragmentary movement and Von Mises' strain distribution. The DTN demonstrated a greater compressive stiffness for the best-case surgical scenario, whereas the MDTP showed higher stiffness (p < 0.05) for the worst-case surgical scenario. In torsional testing, the DTN proved more resistant to torsion in the worst-case surgical setup (p < 0.05) for both ± 4 Nm and ± 8 Nm. The equivalent stiffness of the DTN against the MDTP supports the use of this implant for SMOT fixation and should be considered as a treatment option particularly in patients presenting vascularisation problems where the MDTP is an inappropriate choice.


Assuntos
Pinos Ortopédicos , Placas Ósseas , Fixação Interna de Fraturas/métodos , Osteotomia/métodos , Tíbia/cirurgia , Fraturas da Tíbia/cirurgia , Fenômenos Biomecânicos , Pinos Ortopédicos/efeitos adversos , Placas Ósseas/efeitos adversos , Força Compressiva , Fixação Interna de Fraturas/instrumentação , Humanos , Osteotomia/instrumentação , Torção Mecânica
15.
Sci Rep ; 11(1): 14727, 2021 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-34282216

RESUMO

The work aimed to evaluate the effectiveness of the developed distraction system based on the rod external monolateral fixation mechanisms by comparing it with the classical technique of long tubular bones distraction based on the circular multi-axial system. The study included patients with a genetically confirmed diagnosis of achondroplasia. The experimental group consisted of 14 patients who underwent surgical limb lengthening by the rod monolateral external fixator with a distraction system developed by the authors. The lengthening was performed on 28 segments of tubular bones. The majority of the experimental group patients achieved the lengthening value close to the planned one and the deformation correction. The fixation period was averagely 83.8 ± 3.7 days, the regenerate length was 8.5 ± 0.6 cm, and the mechanical strength of the distraction regenerate was 10.3° ± 2.18°. The rod external fixator with a control distraction system developed by the authors has small dimensions and low weight of the external supporting elements of high durability. It is reported to provide a good psychological tolerance of the treatment process and significantly outperforms the circular multi-axis system. Considering the aforementioned, the proposed apparatus can grant good orthopedic care to patients with achondroplasia.


Assuntos
Acondroplasia/cirurgia , Fixadores Externos , Fixação de Fratura , Osteogênese por Distração , Acondroplasia/patologia , Adolescente , Braço/cirurgia , Criança , Pré-Escolar , Desenho de Equipamento , Feminino , Fêmur/cirurgia , Fixação de Fratura/instrumentação , Fixação de Fratura/métodos , Humanos , Masculino , Osteogênese por Distração/instrumentação , Osteogênese por Distração/métodos , Osteotomia/instrumentação , Osteotomia/métodos , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento
16.
Sci Rep ; 11(1): 14731, 2021 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-34282242

RESUMO

An oblique double-cut rotation osteotomy (ODCRO) enables correcting a complex bone deformation by aligning, in 3D, the distal, middle and proximal bone segments with a target bone, without intersegmental gaps. We propose virtual preoperative planning of an ODCRO. To minimize a residual translation error, we use an optimization algorithm and optimize towards bone length, alignment in the transverse direction, or a balanced reconstruction. We compare the residual alignment error with an oblique single-cut rotation osteotomy using 15 complex bone deformations. The single-cut approach was not feasible in 5 cases, whereas the ODCRO procedure was feasible in all cases. The residual alignment error was smaller for the ODCRO than for the single-cut approach except for one case. In a subset for length reconstruction, the length error of 7.3-21.3 mm was restored to 0.0 mm in 4 of 5 cases, although at the cost of an increased transverse translation. The proposed method renders planning an ODCRO feasible and helps restoring bone alignment and lengthening better than an oblique single-cut rotation osteotomy. Awareness of the challenges and possibilities in preoperative planning of an ODCRO will be of value for future alignment surgery and for patients.


Assuntos
Imageamento Tridimensional , Osteotomia , Rotação , Cirurgia Assistida por Computador/métodos , Calibragem , Simulação por Computador , Estudos de Viabilidade , Humanos , Imageamento Tridimensional/métodos , Osteotomia/instrumentação , Osteotomia/métodos , Osteotomia/normas , Posicionamento do Paciente/métodos , Posicionamento do Paciente/normas , Período Pré-Operatório
17.
Am J Otolaryngol ; 42(6): 103114, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34166964

RESUMO

OBJECTIVE: To evaluate the safety profile and surgical technique for removal of symptomatic exostoses and osteoma of the external auditory canal with a micro-oscillating piezoelectric device. METHOD: A chart review was conducted on patients undergoing piezoelectric canalplasty between 2019 and 2021 at tertiary referral hospital. Surgery was performed by two surgeons with varying experience. Bone removal was achieved using both osteotomy and osteoplasty. Postoperative complications, operative time and hearing outcome were evaluated. RESULTS: The study comprised 16 patients (16 ears). No major complications occurred. The skin of the auditory canal was completely preserved in all patients without injury to the tympanic membrane. Except for one patient with known noise-induced hearing loss, there was no postoperative deterioration of the bone-conduction threshold more than 10 dB HL at any frequency. The difference of the bone-conduction threshold in pure-tone audiometry (average for 0.5, 1, 2 and 4 kHz) three weeks postoperatively had a median of 0.6 dB ± 5.7. One patient complained of temporary new tinnitus. One patient had prolonged wound healing. Mean operative time was comparable with literature data. CONCLUSION: The atraumatic characteristics of the piezoelectric instrument enable low-risk removal of external auditory canal exostoses and osteoma. Through the combination of precise osteotomy and osteoplasty, this novel instrument has the potential to become established in routine canalplasty.


Assuntos
Neoplasias Ósseas/cirurgia , Meato Acústico Externo/cirurgia , Neoplasias da Orelha/cirurgia , Exostose/cirurgia , Osteoma/cirurgia , Osteotomia/instrumentação , Procedimentos Cirúrgicos Otológicos/instrumentação , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Segurança
18.
Plast Reconstr Surg ; 148(2): 309-319, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-34133407

RESUMO

BACKGROUND: Narrowing genioplasty is commonly performed among East Asian populations, as a broad and/or square chin can be aesthetically unappealing. This study was aimed to introduce the home plate-shaped sliding osteotomy technique for narrowing genioplasty and to evaluate the results of this technique. METHODS: A retrospective chart review of 117 patients who underwent home plate-shaped sliding osteotomy alone between 2011 and 2019 was performed. The angles of oblique osteotomy lines and measurements of caudal repositioning, which significantly affect the postoperative chin shape, were evaluated. RESULTS: The home plate-shaped sliding osteotomy technique was successfully accomplished for narrowing genioplasty as an isolated procedure. The mean distance of caudal repositioning was 3.9 ± 0.8 mm, and the mean angles of oblique osteotomy lines were 23.3 ± 4.8 degrees on the right and 21.8 ± 3.5 degrees on the left. This produced an aesthetically pleasing rounded and proportionately narrow chin. The incidence of minor complications was 6.0 percent. There were no major complications. In particular, the risk of inferior alveolar nerve injury was obviated, as an additional mandibular border osteotomy was not typically used with this technique. CONCLUSIONS: This new surgical procedure for narrowing genioplasty provides improved aesthetic results by altering the chin shape, rather than reducing the transverse width of the chin. The versatility of this procedure allows the chin shape to be adjusted with respect to narrowing, vertical lengthening, anterior advancement, and asymmetric or cleft chin correction. The present study suggests that home plate-shaped sliding genioplasty may be an excellent alternative for correcting broad and/or square chins and more complex chin deformities. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.


Assuntos
Mentoplastia/métodos , Osteotomia/métodos , Satisfação do Paciente , Adolescente , Adulto , Placas Ósseas , Parafusos Ósseos , Estética , Feminino , Seguimentos , Mentoplastia/efeitos adversos , Mentoplastia/instrumentação , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Osteotomia/efeitos adversos , Osteotomia/instrumentação , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
19.
J Orthop Surg Res ; 16(1): 343, 2021 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-34049580

RESUMO

BACKGROUND: Surgical resection and reconstruction for low-grade bone sarcoma in the metaphysis of the distal femur remain challenging. We hypothesized that 3D printing osteotomy guide plate could assist to accurately resect the tumor lesion and save the joint function. METHODS: From January 2017 to August 2019, five patients diagnosed with low-grade bone sarcoma in the metaphysis of the distal femur were treated with hemicortical resection using 3D printing guide plate. Autologous bone graft was inactivated in a high-temperature water bath and re-implanted in situ fixed with plate and screw. Patients were followed up from 17 to 33 months. The Musculoskeletal Tumor Society Score was used to evaluate the joint function. X-ray was used to evaluate the bone union. RESULTS: One patient was paracorticular osteosarcoma, and four cases had highly differentiated chondrosarcoma. All cases were involved in the metaphysis of the distal femur. Patients were followed up from 13 to 33 months, with an average of 23.6 months. There was neither post-operation infection, internal fixation loosening, nor fracture occurrence in any of the patients. The Musculoskeletal Tumor Society Score averaged at 28.1, while the International Society of Limb Salvage imaging score examination averaged 89.8%. CONCLUSIONS: Here, we demonstrate that the 3D printing osteotomy guide plate-assisted hemicortical bone resection is a beneficial strategy to effectively resect the primary low-grade malignant bone tumors in the metaphysis of the distal femur and retained satisfied joint function.


Assuntos
Neoplasias Ósseas/cirurgia , Fêmur/cirurgia , Osteossarcoma/cirurgia , Osteotomia/instrumentação , Impressão Tridimensional , Adolescente , Adulto , Idoso , Criança , Feminino , Humanos , Masculino , Osteotomia/métodos , Modelagem Computacional Específica para o Paciente , Adulto Jovem
20.
Vet Rec ; 188(10): e241, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33870528

RESUMO

BACKGROUND: Tibial plateau levelling osteotomy (TPLO) is commonly used to manage cranial cruciate ligament (CrCL) disease. The use of a spherical osteotomy blade (S-TPLO) enables correction of some tibial deformities with three rotational degrees of freedom. METHODS: As a proof of concept, this retrospective study included 45 dogs with CrCL disease that were treated with an S-TPLO. The tibial plateau angle (TPA) was measured preoperatively, immediately after surgery (pTPA0 ) and on postoperative days 42 (pTPA42 ) and 56 (pTPA56 ). Lameness and osteotomy healing were assessed until 56 days postoperatively. RESULTS: Thirty-one dogs had complete CrCL ruptures, and 14 dogs had partial ruptures. Thirty-one dogs had medial meniscal damage. The mean TPA, pTPA0 , pTPA42 and pTPA56 were 26.0°, 7.8°, 8.5° and 8.9°, respectively. The TPA from post-op to follow-up did not vary significantly (p > 1.365). Minor complications occurred in five dogs. The mean lameness score improved significantly from 3.2 preoperatively to 0.9 on day 56 (p < 0.0001). The mean healing score improved significantly from 1.6 on day 42 to 2.2 on day 56 (p < 0.001). CONCLUSION: S-TPLO was successful in treating CrCL disease in stifle joints without tibial deformities, with results comparable to previously reported TPLO outcomes.


Assuntos
Lesões do Ligamento Cruzado Anterior/veterinária , Doenças do Cão/cirurgia , Osteotomia/veterinária , Tíbia/cirurgia , Animais , Lesões do Ligamento Cruzado Anterior/cirurgia , Cães , Desenho de Equipamento , Feminino , Masculino , Osteotomia/instrumentação , Osteotomia/métodos , Estudos Retrospectivos , Resultado do Tratamento