Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 11(1): 6366, 2021 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-33737603

RESUMO

This population-based cross-sectional study was performed to determine the mean corneal endothelial cell density (ECD), coefficient of variation (CV), and hexagonality (HEX), and their associations with myopia in Japanese adults living in Chikusei city. Of 7109 participants with available data, 5713 (2331 male and 3382 female) participants were eligible for analysis. After assessing the relationship between participant characteristics and spherical equivalent refraction (SER), the association of SER with the abnormal value of ECD (< 2000 cells/mm), CV (≥ 0.40), and HEX (≤ 50%) were determined using the logistic regression models adjusting for potential confounders (age, intraocular pressure, keratometric power, height, and antihypertensive drug use). In male participants, there was no statistically significant relationships between SER and endothelial parameters. In female participants, compared to emmetropia, SER ≤ - 6 D had significantly higher odds ratio (OR) of having the abnormal value of CV (OR = 2.07, 95% confidence interval [CI] 1.39-3.10) and HEX (OR = 2.04, 95% CI 1.29-3.23), adjusted for potential confounders, indicating that the high myopia was associated with the abnormal values of CV and HEX. Further adjustment for contact lenses wear partly attenuated these associations. Association between the SER and ECD was not detected.


Assuntos
Córnea/diagnóstico por imagem , Perda de Células Endoteliais da Córnea/diagnóstico por imagem , Endotélio Corneano/diagnóstico por imagem , Miopia/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Contagem de Células/normas , Córnea/patologia , Perda de Células Endoteliais da Córnea/patologia , Emetropia/fisiologia , Células Endoteliais/ultraestrutura , Endotélio Corneano/ultraestrutura , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miopia/diagnóstico por imagem , Miopia/patologia , Refração Ocular/fisiologia
2.
Sci Rep ; 11(1): 6250, 2021 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-33737688

RESUMO

Moxifloxacin hydrochloride (MXF) is widely used for the prevention of bacterial endophthalmitis after intraocular surgeries. However, the safety issue of intracameral injection of MXF for human corneal endothelial cells (HCECs) is still debatable. In this study, we investigated concentration-dependent cytotoxicity (0.05-1 mg/ml) of MXF for immortalized HCECs (B4G12 cell) and the underlying mechanism. Reactive oxygen generation (ROS) and cell viability after MXF exposure was measured. Flow cytometric analysis and TUNEL assay was used to detect apoptotic HCECs after MXF exposure. Ultrastructure of damaged HCECs by MXF was imaged by transmission electron microscope. Western blot analysis and caspase 2, 3 and 8 analysis were used to reveal the underlying mechanism of MXF induced damage in HCECs. We found that MXF induced dose-dependent cytotoxicity in HCECs. MXF exposure increased ROS generation and induced autophagy in HCECs. Increased LDH release represented the cellular membrane damage by MXF. In addition, caspases activation, Bax/Bcl-xL-dependent apoptosis pathway and apoptosis inducing factor nuclear translocation were all involved in MXF induced HCECs' damage, especially after exposure to high dose of MXF (0.5 and 1.0 mg/ml). These findings suggest that MXF toxicity on HCECs should be thoroughly considered by ophthalmologists when intracameral injection of MXF is planned.


Assuntos
Antibacterianos/efeitos adversos , Perda de Células Endoteliais da Córnea/induzido quimicamente , Células Endoteliais/efeitos dos fármacos , Endotélio Corneano/citologia , Moxifloxacina/efeitos adversos , Animais , Antibacterianos/administração & dosagem , Apoptose/efeitos dos fármacos , Autofagia/efeitos dos fármacos , Linhagem Celular Transformada , Sobrevivência Celular/efeitos dos fármacos , Perda de Células Endoteliais da Córnea/diagnóstico por imagem , Células Endoteliais/metabolismo , Humanos , Microscopia Eletrônica de Transmissão/métodos , Moxifloxacina/administração & dosagem , Espécies Reativas de Oxigênio/metabolismo , Transdução de Sinais/efeitos dos fármacos , Suínos
3.
Physiol Res ; 68(5): 827-833, 2019 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-31424248

RESUMO

Biophysical properties and microstructural changes of swelling cornea which caused by endothelial cells damage will be evaluated. Swelling cornea models were established by endothelial cells damage in 114 Sprague Dawley rats. Relative gray value, swelling rate and light transmittance were measured to evaluated the biophysical properties and microstructure changes were observed by transmission electron microscopy. Relative gray value decreased while swelling rate rose along with time and both of them reached relative stability after 7 days. Light transmittance showed a decline trend with time even after corneal thickness had reached stable stage. Observed by transmission electron microscopy, interfibrillar distance increased, fewer proteoglycans coating appeared and remnants proteoglycan branches became thinner and longer in 7 days. Diameter of fibrils didn't change obviously with time. In cornea edema models caused by endothelial cells damage, the changes of biophysical property and microstructure can help us evaluate corneal edema accurately and objectively.


Assuntos
Perda de Células Endoteliais da Córnea/patologia , Substância Própria/patologia , Células Endoteliais/ultraestrutura , Endotélio Corneano/ultraestrutura , Animais , Perda de Células Endoteliais da Córnea/diagnóstico por imagem , Substância Própria/diagnóstico por imagem , Modelos Animais de Doenças , Endotélio Corneano/diagnóstico por imagem , Microscopia Eletrônica de Transmissão , Fotografação , Ratos Sprague-Dawley , Ultrassonografia
4.
Cornea ; 38(4): 426-432, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30664048

RESUMO

PURPOSE: To evaluate agreement between eye banks (EBs) and a reading center on endothelial cell density (ECD) determinations in the Cornea Preservation Time Study. METHODS: The Cornea Image Analysis Reading Center (CIARC) performed variable frame image analysis on EB-obtained-preoperative central endothelial images (after lamellar dissection for Descemet stripping automated endothelial keratoplasty by the EBs or before shipping, if surgeon prepared) to determine ECD. The EBs performed their usual method of ECD determination. The CIARC and EBs also provided ECD determinations from screening central endothelial images taken by the EBs during donor evaluation. Two independent masked CIARC readers determined ECD with measurements averaged. RESULTS: The mean preoperative ECD was 15 cells/mm greater by the EBs than by CIARC (N = 1286, P < 0.001) with 95% limits of agreement of (-644, 675 cells/mm). The limits of agreement in preoperative ECD were wider in the After-Lamellar-Dissection Group (-687, 683 cells/mm) than in the Before Shipping Group [(-505, 633 cells/mm); P = 0.03]. The EBs-determined preoperative ECD was within 10% of the CIARC-determined ECD for 886 (69%) image sets, with 236 (18%) higher by >10% and 164 (13%) lower by >10%. Excellent agreement appeared between the EBs and CIARC when 100-300 cells could be analyzed in contrast to <100 cells (SD = 308 cells/mm vs. SD = 603 cells/mm; P < 0.001). CONCLUSIONS: The mean ECD by the EBs and CIARC were similar, but there was considerable variability between determinations for individual corneas. Agreement improved between the 2 measurements when more than 100 cells were able to be analyzed.


Assuntos
Contagem de Células/métodos , Perda de Células Endoteliais da Córnea/diagnóstico por imagem , Endotélio Corneano/citologia , Bancos de Olhos/estatística & dados numéricos , Processamento de Imagem Assistida por Computador , Adolescente , Adulto , Idoso , Criança , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Endotélio Corneano/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
5.
Exp Eye Res ; 175: 73-82, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29883637

RESUMO

Corneal endothelial cell (CEC) loss occurs from tissue manipulation during anterior segment surgery and corneal transplantation as well as from contact with synthetic materials like intraocular lenses and tube shunts. While several studies have quantified CEC loss for specific surgical steps, the vulnerability of CECs to isolated, controllable and measurable mechanical forces has not been assessed previously. The purpose of this study was to develop an experimental testing platform where the susceptibility of CECs to controlled mechanical trauma could be measured. The corneal endothelial surfaces of freshly dissected porcine corneas were subjected to a range of indentation forces via a spherical stainless steel bead. A cell viability assay in combination with high-resolution fluorescence microscopy was used to visualize and quantify injured/dead CEC densities before and after mechanical loading. In specimens subjected to an indentation force of 9 mN, the mean ±â€¯SD peak contact pressure P0 was 18.64 ±â€¯3.59 kPa (139.81 ±â€¯26.93 mmHg) in the center of indentation and decreased radially outward. Injured/dead CEC densities were significantly greater (p ≤ 0.001) after mechanical indentation of 9 mN (167 ±â€¯97 cells/mm2) compared to before indentation (39 ±â€¯52 cells/mm2) and compared to the sham group (34 ±â€¯31 cells/mm2). In specimens subjected to "contact only" - defined as an applied indentation force of 0.65 mN - the peak contact pressure P0 was 7.31 ±â€¯1.5 kPa (54.83 ±â€¯11.25 mmHg). In regions where the contact pressures was below 78% of P0 (<5.7 kPa or 42.75 mmHg), injured/dead CEC densities were within the range of CEC loss observed in the sham group, suggesting negligible cell death. These findings indicate that CECs are highly susceptible to mechanical trauma via indentation, supporting the established "no-touch" policy for ophthalmological procedures. While CECs can potentially remain viable below contact pressures of 5.7 kPa (42.75 mmHg), this low threshold suggests that prevention of indentation-associated CEC loss may be challenging.


Assuntos
Perda de Células Endoteliais da Córnea/etiologia , Técnicas de Imagem por Elasticidade , Endotélio Corneano/lesões , Endotélio Corneano/patologia , Traumatismos Oculares/etiologia , Microscopia de Fluorescência , Estresse Mecânico , Ferimentos não Penetrantes/etiologia , Animais , Contagem de Células , Sobrevivência Celular , Perda de Células Endoteliais da Córnea/diagnóstico por imagem , Perda de Células Endoteliais da Córnea/fisiopatologia , Endotélio Corneano/diagnóstico por imagem , Traumatismos Oculares/diagnóstico por imagem , Traumatismos Oculares/fisiopatologia , Microesferas , Suínos , Ferimentos não Penetrantes/diagnóstico por imagem , Ferimentos não Penetrantes/fisiopatologia
6.
Cornea ; 36(11): 1295-1301, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28991851

RESUMO

PURPOSE: Availability of preloaded Descemet membrane endothelial keratoplasty (pDMEK) tissue may increase acceptance of DMEK in surgical management of endothelial disease. The goal of this study was to determine the safety of pDMEK grafts for 24 hours before surgery by analyzing endothelial cell loss (ECL) using 2 image analysis software programs. METHODS: A total of 18 cadaveric corneas were prepared for DMEK using a standardized technique and loaded in a modified Jones tube injector. Nine of the corneas were injected into Calcein AM vital dye after 1 minute (controls), and the remaining 9 corneas were left preloaded for 24 hours before injection into vital dye for staining. The stained corneas were imaged using an inverted confocal microscope. ECL was then analyzed and quantified by 2 different graders using 2 image analysis software programs. RESULTS: The control DMEK tissue resulted in 22.0% ± 4.0% ECL compared with pDMEK tissue, which resulted in 19.2% ± 7.2% ECL (P = 0.31). Interobserver agreement was 0.93 for MetaMorph and 0.92 for Fiji. The average time required to process images with MetaMorph was 2 ± 1 minutes and with Fiji was 20 ± 10 minutes. Intraobserver agreement was 0.97 for MetaMorph and 0.93 for Fiji. CONCLUSIONS: Preloading DMEK tissue is safe and may provide an alternative technique for tissue distribution and surgery for DMEK. The use of MetaMorph software for quantifying ECL is a novel and accurate imaging method with increased efficiency and reproducibility compared with the previously validated Fiji.


Assuntos
Perda de Células Endoteliais da Córnea/diagnóstico por imagem , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Preservação de Órgãos/métodos , Coleta de Tecidos e Órgãos , Contagem de Células , Sobrevivência Celular , Fluoresceínas/administração & dosagem , Corantes Fluorescentes/administração & dosagem , Humanos , Processamento de Imagem Assistida por Computador , Microscopia Confocal , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Coloração e Rotulagem , Doadores de Tecidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...