Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 15.986
Filtrar
1.
Sci Rep ; 14(1): 11442, 2024 05 20.
Artigo em Inglês | MEDLINE | ID: mdl-38769440

RESUMO

The global supply of fluoropolymers and fluorinated solvents is decreasing due to environmental concerns regarding polyfluoroalkyl substances. CYTOP has been used for decades primarily as a component of a femtoliter chamber array for digital bioanalysis; however, its supply has recently become scarce, increasing the urgency of fabricating a femtoliter chamber array using alternative materials. In this study, we investigated the feasibility of fabricating a femtoliter chamber array using four types of fluoropolymers in stable supply as candidate substitutes and verified their applicability for digital bioanalysis. Among these candidates, Fluorine Sealant emerged as a viable option for fabricating femtoliter chamber arrays using a conventional photolithography process. To validate its efficacy, we performed various digital bioanalysis using FP-A-based chamber arrays with model enzymes such as CRISPR-Cas, horseradish peroxidase, and ß-galactosidase. The results demonstrated the similar performance to that of CYTOP, highlighting the broader utility of FP-A in digital bioanalysis. Our findings underscore the potential of FP-A to enhance the versatility of digital bioanalysis and foster the ongoing advancement of innovative diagnostic technologies.


Assuntos
Polímeros , Polímeros/química , Peroxidase do Rábano Silvestre/metabolismo , Peroxidase do Rábano Silvestre/química , beta-Galactosidase/metabolismo
2.
Biomacromolecules ; 25(5): 3055-3062, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38693874

RESUMO

Polymersomes, nanosized polymeric vesicles, have attracted significant interest in the areas of artificial cells and nanomedicine. Given their size, their visualization via confocal microscopy techniques is often achieved through the physical incorporation of fluorescent dyes, which however present challenges due to potential leaching. A promising alternative is the incorporation of molecules with aggregation-induced emission (AIE) behavior that are capable of fluorescing exclusively in their assembled state. Here, we report on the use of AIE polymersomes as artificial organelles, which are capable of undertaking enzymatic reactions in vitro. The ability of our polymersome-based artificial organelles to provide additional functionality to living cells was evaluated by encapsulating catalytic enzymes such as a combination of glucose oxidase/horseradish peroxidase (GOx/HRP) or ß-galactosidase (ß-gal). Via the additional incorporation of a pyridinium functionality, not only the cellular uptake is improved at low concentrations but also our platform's potential to specifically target mitochondria expands.


Assuntos
Glucose Oxidase , Peroxidase do Rábano Silvestre , beta-Galactosidase , Glucose Oxidase/química , Humanos , beta-Galactosidase/química , beta-Galactosidase/metabolismo , Peroxidase do Rábano Silvestre/química , Peroxidase do Rábano Silvestre/metabolismo , Organelas/metabolismo , Corantes Fluorescentes/química , Polímeros/química , Fluorescência , Células HeLa , Mitocôndrias/metabolismo
3.
J Am Chem Soc ; 146(19): 13247-13257, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38701006

RESUMO

Horseradish peroxidase (HRP) is an enzyme that oxidizes pollutants from wastewater. A previous report indicated that peroxidases can have an enhancement in initial enzymatic activity in an aqueous solution of 0.26 M 1-ethyl-3-methylimidazolium ethyl sulfate ([EMIm][EtSO4]) at neutral pH. However, the atomistic details remain elusive. In the enzymatic landscape of HRP, compound II (Cpd II) plays a key role and involves a histidine (H42) residue. Cpd II exists as oxoferryl (2a) or hydroxoferryl (2b(FeIV)) forms, where 2a is the predominantly observed form in experimental studies. Intriguingly, the ferric 2b(FeIII) form seen in synthetic complexes has not been observed in HRP. Here, we have investigated the structure and dynamics of HRP in pure water and aqueous [EMIm][EtSO4] (0.26 M), as well as the reaction mechanism of 2a to 2b conversion using polarizable molecular dynamics (MD) simulations and quantum mechanics/molecular mechanics (QM/MM) calculations. When HRP is solvated in aq [EMIm][EtSO4], the catalytic water displaces, and H42 directly orients over the ferryl moiety, allowing a direct proton transfer (PT) with a significant energy barrier reduction. Conversely, in neat water, the reaction of 2a to 2b follows the previously reported mechanism. We further investigated the deprotonated form of H42. Analysis of the electric fields at the active site indicates that the aq [EMIm][EtSO4] medium facilitates the reaction by providing a more favorable environment compared with the system solvated in neat water. Overall, the atomic level supports the previous experimental observations and underscores the importance of favorable electric fields in the active site to promote catalysis.


Assuntos
Peroxidase do Rábano Silvestre , Líquidos Iônicos , Simulação de Dinâmica Molecular , Peroxidase do Rábano Silvestre/química , Peroxidase do Rábano Silvestre/metabolismo , Líquidos Iônicos/química , Imidazóis/química , Teoria Quântica , Soluções , Água/química
4.
ACS Appl Bio Mater ; 7(5): 3506-3514, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38696441

RESUMO

Horseradish peroxidase (HRP)-mediated hydrogelation, caused by the cross-linking of phenolic groups in polymers in the presence of hydrogen peroxide (H2O2), is an effective route for bioink solidification in 3D bioprinting. Sugar beet pectin (SBP) naturally has cross-linkable phenols through the enzymatic reaction. Therefore, chemical modifications are not required, unlike the various polymers that have been used in the enzymatic cross-linking system. In this study, we report the application of SBP in extrusion-based bioprinting including HRP-mediated bioink solidification. In this system, H2O2 necessary for the solidification of inks is supplied in the gas phase. Cell-laden liver lobule-like constructs could be fabricated using bioinks consisting of 10 U/mL HRP, 4.0 and 6.0 w/v% SBP, and 6.0 × 106 cells/mL human hepatoblastoma (HepG2) cells exposed to air containing 16 ppm of H2O2 concurrently during printing and 10 min postprinting. The HepG2 cells enclosed in the printed constructs maintained their viability, metabolic activity, and hepatic functions from day 1 to day 7 of the culture, which indicates the cytocompatibility of this system. Taken together, this result demonstrates the potential of SBP and HRP cross-linking systems for 3D bioprinting, which can be applied in tissue engineering applications.


Assuntos
Beta vulgaris , Materiais Biocompatíveis , Bioimpressão , Peroxidase do Rábano Silvestre , Teste de Materiais , Pectinas , Impressão Tridimensional , Peroxidase do Rábano Silvestre/metabolismo , Peroxidase do Rábano Silvestre/química , Beta vulgaris/química , Humanos , Pectinas/química , Células Hep G2 , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Materiais Biocompatíveis/síntese química , Peróxido de Hidrogênio/química , Tamanho da Partícula , Sobrevivência Celular/efeitos dos fármacos , Reagentes de Ligações Cruzadas/química , Reagentes de Ligações Cruzadas/síntese química , Engenharia Tecidual
5.
Talanta ; 275: 126156, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38692048

RESUMO

The development of simple methods for the isolation and quantification of exosomes in biological samples is important. By using the typical two-dimensional (2D) nanomaterials, graphene oxide (GO), the present work first studied the interaction of liposomes with the nanocomposites formed by adsorbing HRP on the GO surface and found the presence of liposomes led to the release of HRP from the GO surface to the solution phase triggering the luminol-H2O2 chemiluminescence (CL) reaction to emit light. Benefiting from the similarity of exosomes to liposomes in both composition and morphology aspects, the GO-HRP nanocomposites with a mass ratio of 120:1 and 160:1 were employed for the quantitative detection of exosomes in 100-fold diluted serum samples. The whole detection process took about 15 min and as low as 3.2 × 102 particles µL-1 of exosomes could be sensitively detected. In addition to GO-HRP nanocomposites, the CL responses of other nanocomposites obtained from adsorbing HRP on other 2D nanomaterials such as layered MoS2 for exosomes were also tested. MoS2-HRP exhibited similar behavior and the LODs for the detection of exosomes were 5.8 × 102 particles µL-1. The proposed assays were a biomarker-independent quantitative method that achieved the quantification of exosomes in serum samples directly without an isolation process.


Assuntos
Exossomos , Grafite , Peroxidase do Rábano Silvestre , Medições Luminescentes , Nanoestruturas , Exossomos/química , Grafite/química , Peroxidase do Rábano Silvestre/química , Medições Luminescentes/métodos , Adsorção , Humanos , Nanoestruturas/química , Luminol/química , Molibdênio/química , Dissulfetos/química , Peróxido de Hidrogênio/química , Limite de Detecção , Lipossomos/química , Nanocompostos/química
6.
Nano Lett ; 24(15): 4682-4690, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38563501

RESUMO

Multienzyme assemblies mediated by multivalent interaction play a crucial role in cellular processes. However, the three-dimensional (3D) programming of an enzyme complex with defined enzyme activity in vitro remains unexplored, primarily owing to limitations in precisely controlling the spatial topological configuration. Herein, we introduce a nanoscale 3D enzyme assembly using a tetrahedral DNA framework (TDF), enabling the replication of spatial topological configuration and maintenance of an identical edge-to-edge distance akin to natural enzymes. Our results demonstrate that 3D nanoscale enzyme assemblies in both two-enzyme systems (glucose oxidase (GOx)/horseradish peroxidase (HRP)) and three-enzyme systems (amylglucosidase (AGO)/GOx/HRP) lead to enhanced cascade catalytic activity compared to the low-dimensional structure, resulting in ∼5.9- and ∼7.7-fold enhancements over homogeneous diffusional mixtures of free enzymes, respectively. Furthermore, we demonstrate the enzyme assemblies for the detection of the metabolism biomarkers creatinine and creatine, achieving a low limit of detection, high sensitivity, and broad detection range.


Assuntos
Enzimas Imobilizadas , Glucose Oxidase , Enzimas Imobilizadas/química , Peroxidase do Rábano Silvestre/química , Glucose Oxidase/química , DNA/química
7.
Anal Chem ; 96(18): 7281-7288, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38663032

RESUMO

Single-cell spatial proteomic analysis holds great promise to advance our understanding of the composition, organization, interaction, and function of the various cell types in complex biological systems. However, the current multiplexed protein imaging technologies suffer from low detection sensitivity, limited multiplexing capacity, or are technically demanding. To tackle these issues, here, we report the development of a highly sensitive and multiplexed in situ protein profiling method using off-the-shelf antibodies. In this approach, the protein targets are stained with horseradish peroxidase (HRP) conjugated antibodies and cleavable fluorophores via click chemistry. Through repeated cycles of target staining, fluorescence imaging, and fluorophore cleavage, many proteins can be profiled in single cells in situ. Applying this approach, we successfully quantified 28 different proteins in human formalin-fixed paraffin-embedded (FFPE) tonsil tissue, which represents the highest multiplexing capacity among the tyramide signal amplification (TSA) methods. Based on their unique protein expression patterns and their microenvironment, ∼820,000 cells in the tissue are classified into distinct cell clusters. We also explored the cell-cell interactions between these varied cell clusters and observed that different subregions of the tissue are composed of cells from specific clusters.


Assuntos
Química Click , Corantes Fluorescentes , Tonsila Palatina , Humanos , Corantes Fluorescentes/química , Tonsila Palatina/citologia , Tonsila Palatina/química , Tonsila Palatina/metabolismo , Análise de Célula Única , Proteínas/análise , Proteínas/química , Proteínas/metabolismo , Proteômica/métodos , Peroxidase do Rábano Silvestre/química , Peroxidase do Rábano Silvestre/metabolismo , Imagem Óptica , Inclusão em Parafina
8.
J Mater Chem B ; 12(16): 3996-4003, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38563677

RESUMO

Encapsulation of enzymes within porous materials has shown great promise for protecting enzymes from denaturation, increasing their tolerance to harsh environments and promoting their industrialization. However, controlling the conformational freedom of the encapsulated enzymes to enhance their catalytic performance remains a great challenge. To address this issue, herein, following immobilization of GOx and HRP on a thermo-responsive porous poly(styrene-maleic-anhydride-N-isopropylacrylamide) (PSMN) membrane, a GOx-HRP@PSMN@HZIF-8 composite was fabricated by encapsulating GOx-HRP@PSMN in hollow ZIF-8 (HZIF-8) with liposome (L) as the sacrificial template. The improved conformational freedom for enzymes arising from the hollow cavity formed in ZIF-8 through the removal of L enhanced the mass transfer and dramatically promoted the catalytic activity of the composite. Interestingly, at high temperature, the coiled PN moiety in PSMN provided the confinement effect for GOx-HRP, which also significantly boosted the catalytic performance of the composites. Compared to the maximum catalytic reaction rates (Vmax) of GOx-HRP@PSMN@LZIF-8, the free enzyme and GOx-HRP@ZIF-8, the Vmax of the GOx-HRP@PSMN@HZIF-8 composite exhibited an impressive 17.8-fold, 10.8-fold and 6.0-fold enhancement at 37 °C, respectively. The proposed composites successfully demonstrated their potential as catalytic platforms for the colorimetric detection of glucose in a cascade reaction. This study paves a new way for overcoming the current limitations of immobilizing enzymes in porous materials and the use of smart polymers for the potential fabrication of enzyme@polymer@MOF composites with tunable conformational freedom and confinement effect.


Assuntos
Enzimas Imobilizadas , Glucose Oxidase , Estruturas Metalorgânicas , Enzimas Imobilizadas/química , Enzimas Imobilizadas/metabolismo , Estruturas Metalorgânicas/química , Glucose Oxidase/química , Glucose Oxidase/metabolismo , Peroxidase do Rábano Silvestre/química , Peroxidase do Rábano Silvestre/metabolismo , Polímeros/química , Propriedades de Superfície , Porosidade , Tamanho da Partícula , Catálise , Biocatálise , Poliestirenos/química
9.
Spectrochim Acta A Mol Biomol Spectrosc ; 315: 124236, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38615415

RESUMO

In this work, a colorimetric aptasensor based on magnetic beads (MBs), gold nanoparticles (AuNPs) and Horseradish Peroxidase (HRP) was prepared for the detection of mucin 1 (MUC1). Complementary DNA of the MUC1 aptamer (Apt) immobilized on the MBs was combined with the prepared AuNPs-Apt-HRP complex (AuNPs@Apt-HRP). In the presence of MUC1, it specifically bound to Apt, resulting in the detachment of gold nanoparticles from the MBs. After magnetic separation, AuNPs@Apt-HRP was separated into the supernatant and reacted with 3,3',5,5'-Tetramethylbenzidine (TMB) to produce color reaction from colorless to blue. The linear range of MUC1 was from 75 to 500 µg/mL (R2 = 0.9878), and the detection limit was 41.95 µg/mL. The recovery rate of MUC1 in human serum was 99.18 %∼101.15 %. This method is simple and convenient. Moreover, it does not require complex and expensive equipment for detection of MUC1. It provides value for the development of MUC1 colorimetric sensors and a promising strategy for the determination of MUC1 in clinical diagnosis.


Assuntos
Aptâmeros de Nucleotídeos , Benzidinas , Técnicas Biossensoriais , Colorimetria , Ouro , Limite de Detecção , Nanopartículas Metálicas , Mucina-1 , Mucina-1/análise , Mucina-1/sangue , Colorimetria/métodos , Ouro/química , Aptâmeros de Nucleotídeos/química , Nanopartículas Metálicas/química , Humanos , Técnicas Biossensoriais/métodos , Peroxidase do Rábano Silvestre/química , Peroxidase do Rábano Silvestre/metabolismo
10.
Biosens Bioelectron ; 256: 116262, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38621340

RESUMO

Lateral flow immunoassays (LFIAs) are an essential and widely used point-of-care test for medical diagnoses. However, commercial LFIAs still have low sensitivity and specificity. Therefore, we developed an automatic ultrasensitive dual-color enhanced LFIA (DCE-LFIA) by applying an enzyme-induced tyramide signal amplification method to a double-antibody sandwich LFIA for antigen detection. The DCE-LFIA first specifically captured horseradish peroxidase (HRP)-labeled colored microspheres at the Test line, and then deposited a large amount of tyramide-modified signals under the catalytic action of HRP to achieve the color superposition. A limit of detection (LOD) of 3.9 pg/mL and a naked-eye cut-off limit of 7.8 pg/mL were achieved for detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleoprotein. Additionally, in the inactivated virus detections, LOD equivalent to chemiluminescence (0.018 TCID50/mL) was obtained, and it had excellent specificity under the interference of other respiratory viruses. High sensitivity has also been achieved for detection of influenza A, influenza B, cardiac troponin I, and human chorionic gonadotrophin using this DCE-LFIA, suggesting the assay is universally applicable. To ensure the convenience and stability in practical applications, we created an automatic device. It provides a new practical option for point-of-care test immunoassays, especially ultra trace detection and at-home testing.


Assuntos
Técnicas Biossensoriais , COVID-19 , Limite de Detecção , SARS-CoV-2 , Imunoensaio/instrumentação , Imunoensaio/métodos , Humanos , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/imunologia , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , COVID-19/diagnóstico , COVID-19/virologia , Peroxidase do Rábano Silvestre/química , Troponina I/sangue , Troponina I/análise , Testes Imediatos , Proteínas do Nucleocapsídeo de Coronavírus/imunologia , Proteínas do Nucleocapsídeo de Coronavírus/análise , Gonadotropina Coriônica/análise , Gonadotropina Coriônica/sangue , Vírus da Influenza A/isolamento & purificação , Vírus da Influenza A/imunologia , Fosfoproteínas
11.
Anal Chem ; 96(16): 6337-6346, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38613479

RESUMO

The arsM gene is a critical biomarker for the potential risk of arsenic exposure in paddy soil. However, on-site screening of arsM is limited by the lack of high-throughput point-of-use (POU) methods. Here, a multiplex CRISPR/Cas12a microfluidic paper-based analytical device (µPAD) was constructed for the high-throughput POU analysis of arsM, with cascade amplification driven by coupling crRNA-enhanced Cas12a and horseradish peroxidase (HRP)-modified probes. First, seven crRNAs were designed to recognize arsM, and their LODs and background signal intensities were evaluated. Next, a step-by-step iterative approach was utilized to develop and optimize coupling systems, which improved the sensitivity 32 times and eliminated background signal interference. Then, ssDNA reporters modified with HRP were introduced to further lower the LOD to 16 fM, and the assay results were visible to the naked eye. A multiplex channel microfluidic paper-based chip was developed for the reaction integration and simultaneous detection of 32 samples and generated a recovery rate between 87.70 and 114.05%, simplifying the pretreatment procedures and achieving high-throughput POU analysis. Finally, arsM in Wanshan paddy soil was screened on site, and the arsM abundance ranged from 1.05 × 106 to 6.49 × 107 copies/g; this result was not affected by the environmental indicators detected in the study. Thus, a coupling crRNA-based cascade amplification method for analyzing arsM was constructed, and a microfluidic device was developed that contains many more channels than previous paper chips, greatly improving the analytical performance in paddy soil samples and providing a promising tool for the on-site screening of arsM at large scales.


Assuntos
Solo , Solo/química , Peroxidase do Rábano Silvestre/metabolismo , Peroxidase do Rábano Silvestre/química , Sistemas CRISPR-Cas , Oryza/química , Poluentes do Solo/análise , Dispositivos Lab-On-A-Chip , Endodesoxirribonucleases/metabolismo , Endodesoxirribonucleases/química , Ensaios de Triagem em Larga Escala/métodos , Proteínas de Bactérias/genética , Proteínas de Bactérias/metabolismo , Proteínas Associadas a CRISPR/metabolismo , Limite de Detecção , Técnicas de Amplificação de Ácido Nucleico/métodos
12.
Anal Sci ; 40(5): 951-958, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38598048

RESUMO

Daily monitoring of serum uric acid levels is very important to provide appropriate treatment according to the constitution and lifestyle of individual hyperuricemic patients. We have developed a suspension-based assay to measure uric acid by adding a sample solution to the suspension containing micro-sized particles immobilized on uricase and horseradish peroxidase (HRP). In the proposed method, the mediator reaction of uricase, HRP, and uric acid produces resorufin from Amplex red. This resorufin is adsorbed onto enzyme-immobilized micro-sized particles simultaneously with its production, resulting in the red color of the micro-sized particles. The concentration of resorufin on the small surface area of the microscopic particles achieves a colorimetric analysis of uric acid with superior visibility. In addition, ethanol-induced desorption of resorufin allowed quantitative measurement of uric acid using a 96-well fluorescent microplate reader. The limit of detection (3σ) and RSD (n = 3) were estimated to be 2.2 × 10-2 µg/mL and ≤ 12.1%, respectively. This approach could also be applied to a portable fluorometer.


Assuntos
Colorimetria , Enzimas Imobilizadas , Fluorometria , Peroxidase do Rábano Silvestre , Urato Oxidase , Ácido Úrico , Ácido Úrico/sangue , Ácido Úrico/química , Ácido Úrico/análise , Enzimas Imobilizadas/química , Enzimas Imobilizadas/metabolismo , Urato Oxidase/química , Urato Oxidase/metabolismo , Peroxidase do Rábano Silvestre/química , Peroxidase do Rábano Silvestre/metabolismo , Tamanho da Partícula , Humanos , Suspensões , Oxazinas/química
13.
Biosensors (Basel) ; 14(4)2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38667176

RESUMO

The identification and quantification of biomarkers with innovative technologies is an urgent need for the precise diagnosis and follow up of human diseases. Body fluids offer a variety of informative biomarkers, which are traditionally measured with time-consuming and expensive methods. In this context, lateral flow tests (LFTs) represent a rapid and low-cost technology with a sensitivity that is potentially improvable by chemiluminescence biosensing. Here, an LFT based on gold nanoparticles functionalized with antibodies labeled with the enzyme horseradish peroxidase is combined with a lensless biosensor. This biosensor comprises four Silicon Photomultipliers (SiPM) coupled in close proximity to the LFT strip. Microfluidics for liquid handling complete the system. The development and the setup of the biosensor is carefully described and characterized. C-reactive protein was selected as a proof-of-concept biomarker to define the limit of detection, which resulted in about 0.8 pM when gold nanoparticles were used. The rapid readout (less than 5 min) and the absence of sample preparation make this biosensor promising for the direct and fast detection of human biomarkers.


Assuntos
Biomarcadores , Técnicas Biossensoriais , Ouro , Nanopartículas Metálicas , Biomarcadores/análise , Humanos , Ouro/química , Nanopartículas Metálicas/química , Medições Luminescentes , Proteína C-Reativa/análise , Peroxidase do Rábano Silvestre , Limite de Detecção
14.
Chemosphere ; 358: 142145, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38670514

RESUMO

This research reported on the immobilization of environmentally friendly enzymes, such as horseradish peroxidase (HRP) and laccase (L), along with the hydrophilic zwitterionic compound l-DOPA on nano-filtration (NF) membranes. This approach introduced biocatalytic membranes, leveraging combined effects between membranes and enzymes. The aim was to systematically assess the efficacy of the enzymatic modified membrane (HRP-NF) in degrading colors in the wastewater, as well as enhancing the membrane resistance toward organic fouling. The enzymatic immobilized membrane demonstrated 96.3 ± 1.8% to 96.6 ± 1.9% removal of colors, and 65.2 ± 1.3% to 67.2 ± 1.3% removal of TOC. This result was underpinned by the insights obtained from the radical scavenger coumarin, which was employed to trap and confirm the formation of PRs through the reaction of enzymes and H2O2. Furthermore, membranes modified with enzymes exhibited significantly improved antifouling properties. The HRP-NF membrane experienced an 8% decline in flux, while the co-immobilized HRP-L-NF membrane demonstrated as low as 6% flux decline, contributed by the synergistic effect of increased hydrophilicity and biocatalytic effects. These findings confirmed that the immobilized enzymatic surface has added function of degrading contaminants in addition to separation function of nanofiltration membrane. These l-DOPA-immobilized enzymatic membranes offered a promising hybrid biocatalytic membrane to eliminate dyes and mitigate membrane fouling, which can be applied in many industrial and domestic water and wastewater treatment.


Assuntos
Biocatálise , Enzimas Imobilizadas , Peroxidase do Rábano Silvestre , Lacase , Membranas Artificiais , Águas Residuárias , Poluentes Químicos da Água , Lacase/metabolismo , Lacase/química , Peroxidase do Rábano Silvestre/metabolismo , Peroxidase do Rábano Silvestre/química , Enzimas Imobilizadas/química , Enzimas Imobilizadas/metabolismo , Águas Residuárias/química , Poluentes Químicos da Água/química , Incrustação Biológica/prevenção & controle , Interações Hidrofóbicas e Hidrofílicas , Filtração/métodos , Levodopa/química , Purificação da Água/métodos , Peróxido de Hidrogênio/química , Eliminação de Resíduos Líquidos/métodos
15.
Biosensors (Basel) ; 14(3)2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38534242

RESUMO

The ongoing COVID-19 pandemic, driven by persistent SARS-CoV-2 transmission, threatens human health worldwide, underscoring the urgent need for an efficient, low-cost, rapid SARS-CoV-2 detection method. Herein, we developed a point-of-care SARS-CoV-2 detection method incorporating recombinase polymerase amplification (RPA) and DNA-protein crosslinking chemiluminescence (DPCL) (RPADPCL). RPADPCL involves the crosslinking of biotinylated double-stranded RPA DNA products with horseradish peroxidase (HRP)-labeled streptavidin (SA-HRP). Modified products are captured using SA-labeled magnetic beads, and then analyzed using a chemiluminescence detector and smartphone after the addition of a chemiluminescent substrate. Under optimal conditions, the RPADPCL limit of detection (LOD) was observed to be 6 copies (within the linear detection range of 1-300 copies) for a plasmid containing the SARS-CoV-2 N gene and 15 copies (within the linear range of 10-500 copies) for in vitro transcribed (IVT) SARS-CoV-2 RNA. The proposed method is convenient, specific, visually intuitive, easy to use, and does not require external excitation. The effective RPADPCL detection of SARS-CoV-2 in complex matrix systems was verified by testing simulated clinical samples containing 10% human saliva or a virus transfer medium (VTM) spiked with a plasmid containing a SARS-CoV-2 N gene sequence or SARS-CoV-2 IVT RNA. Consequently, this method has great potential for detecting targets in clinical samples.


Assuntos
COVID-19 , Recombinases , Humanos , SARS-CoV-2 , Luminescência , Pandemias , Sistemas Automatizados de Assistência Junto ao Leito , RNA Viral , Peroxidase do Rábano Silvestre , Técnicas de Amplificação de Ácido Nucleico , Sensibilidade e Especificidade
16.
J Am Chem Soc ; 146(12): 8228-8241, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38471004

RESUMO

It remains a tremendous challenge to explore effective therapeutic modalities against neuroblastoma, a lethal cancer of the sympathetic nervous system with poor prognosis and disappointing treatment outcomes. Considering the limitations of conventional treatment modalities and the intrinsic vulnerability of neuroblastoma, we herein develop a pioneering sequential catalytic therapeutic system that utilizes lactate oxidase (LOx)/horseradish peroxidase (HRP)-loaded amorphous zinc metal-organic framework, named LOx/HRP-aZIF, in combination with a 3-indole-acetic acid (IAA) prodrug. On the basis of abnormal lactate accumulation that occurs in the tumor microenvironment, the cascade reaction of LOx and HRP consumes endogenous glutathione and a reduced form of nicotinamide adenine dinucleotide to achieve the first stage of killing cancer cells via antioxidative incapacitation and electron transport chain interference. Furthermore, the generation of reactive oxygen species induced by HRP and IAA through bioorthogonal catalysis promotes ferritin degradation and lipid peroxidation, ultimately provoking self-enhanced ferroptosis with positive feedback by initiating an endogenous Fenton reaction. This work highlights the superiority of the natural enzyme-dependent cascade and bioorthogonal catalytic reaction, offering a paradigm for synergistically enzyme-based metabolism-ferroptosis anticancer therapy.


Assuntos
Ferroptose , Neoplasias , Neuroblastoma , Humanos , Antioxidantes/farmacologia , Peroxidase do Rábano Silvestre/metabolismo , Catálise , Linhagem Celular Tumoral , Microambiente Tumoral
17.
Mikrochim Acta ; 191(4): 209, 2024 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-38499840

RESUMO

A novel colorimetric platform was designed for the determination of S. aureus by utilizing a dual-recognition strategy, where wheat germ agglutinin (WGA)-functionalized magnetic beads were served as separation elements to capture and enrich S. aureus efficiently from the matrix. Horseradish peroxidase (HRP) labeled chicken anti-protein A IgY (HRP-IgY) was used to label the captured S. aureus. A chicken IgY was introduced as a signal tracer to bind with staphylococcal protein A (SPA) on the surface of S. aureus, which can circumvent the interference from protein G-producing Streptococcus. Subsequently, the colorimetric signal was achieved by an HRP-catalyzed reaction, which was amplified by HRP-IgY bound by approximately 80,000 SPA molecules on one S. aureus. The entire detection process could be accomplished within 90 min. Under optimal conditions, the linear response of different S. aureus concentrations ranged from 7.8 × 102 to 2.0 × 105 CFU/mL and the limit of detection reached down to 3.9 × 102 CFU/mL. Some common non-target bacteria yielded negative results, indicating the excellent specificity of the method. The developed strategy was successfully applied to the determination of S. aureus in various types of samples with satisfactory recoveries. Therefore, the novel dual-recognition strategy possessed the advantages of high sensitivity, specificity, and low cost and exhibited considerable potential as a promising tool to defend public health.


Assuntos
Infecções Estafilocócicas , Staphylococcus aureus , Humanos , Aglutininas do Germe de Trigo , Colorimetria/métodos , Imunoglobulinas , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/microbiologia , Peroxidase do Rábano Silvestre/metabolismo
18.
Analyst ; 149(8): 2223-2226, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38506234

RESUMO

Nanozymes have been widely used as enzyme substitutes. Based on a comprehensive literature survey of 261 publications, we report the significant differences in the Michaelis-Menten constants (Km) between peroxidase-mimicking nanozymes and horseradish peroxidase (HRP). Further, these differences were not considered in more than 60% of the publications for analytical developments. As a result, nanozymes' catalytic activity is limited, resulting in a potentially higher limit of detection (LOD). We used a peroxidase-mimicking Au@Pt nanozyme, which has Km for TMB comparable with HRP and three orders of magnitude higher Km for H2O2. Using the Au@Pt nanozyme as a label for immunoassays, non-optimized nanozyme substrate concentrations led to 30 times higher LOD compared to optimized conditions. The results confirm the necessity of measuring nanozymes' kinetic parameters and the corresponding adjustment of substrate concentrations for highly sensitive detection.


Assuntos
Peróxido de Hidrogênio , Peroxidases , Peróxido de Hidrogênio/química , Catálise , Peroxidase/química , Peroxidase do Rábano Silvestre/química , Colorimetria/métodos
19.
Talanta ; 273: 125851, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38447339

RESUMO

This work presents the first bioplatform described to date for the determination of galactose-α-1,3-galactose (α-Gal), a non-primate mammalian oligosaccharide responsible for almost all cases of red meat allergy. The bioplatform is based on the implementation of an indirect competitive immunoassay and enzymatic labeling with the enzyme horseradish peroxidase (HRP) built on the surface of magnetic microparticles (MBs) and amperometric transduction on screen-printed carbon electrodes (SPCEs) using the H2O2/hydroquinone (HQ) system. The target α-Gal competed with biotinylated α-Gal immobilized on the surface of neutravidin-modified MBs for the limited immunorecognition sites of a detection antibody enzymatically labeled with an HRP-conjugated secondary antibody. The resulting magnetic immunoconjugates were trapped on the surface of the SPCE working electrode and amperometric transduction was performed, providing a cathodic current variation inversely proportional to the concentration of α-Gal in the analyzed sample. The developed biotool was optimized, characterized and applied with satisfactory results to the determination of the target allergen in different samples of raw and processed meats.


Assuntos
Alérgenos , Técnicas Biossensoriais , Hipersensibilidade Alimentar , Animais , Galactose , Peróxido de Hidrogênio/química , Peroxidase do Rábano Silvestre , Peroxidase , Carne , Técnicas Biossensoriais/métodos , Eletrodos , Técnicas Eletroquímicas/métodos , Mamíferos
20.
Talanta ; 273: 125925, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38527412

RESUMO

In the present study, we propose a scheme for detecting H2O2 by using horseradish peroxidase (HRP) adsorbed onto single silica particles and fluorescence microspectroscopy. When the silica particles were immersed in an HRP solution, the HRP concentration in the silica particles increased by a factor of 690 compared to that in the bulk aqueous solution because HRP was adsorbed on the silica surface. When a single particle containing HRP was added to a mixed solution of H2O2 and Amplex Red, fluorescence from resorufin, which was produced by the reaction of HRP, H2O2, and Amplex Red, was observed. The fluorescence from the resorufin in the particles increased after a single particle was added to the solution, and the release of resorufin was observed. As the concentration of H2O2 (CH2O2) decreased, the time it takes for fluorescence intensity to reach its maximum was shorter. The detection limit for H2O2 in the present system was 980 nM. The reaction behavior of a single silica particle was evaluated using a spherical diffusion model, which explains the approximate concentration change of resorufin in the silica particle. The proposed method has the advantages of simple sample preparation and detection, low sample consumption, and a short detection time.


Assuntos
Peróxido de Hidrogênio , Dióxido de Silício , Peróxido de Hidrogênio/química , Peroxidase do Rábano Silvestre/química , Fluorescência , Cinética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...