Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.584
Filtrar
1.
Sci Rep ; 14(1): 5291, 2024 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-38438467

RESUMO

This study aimed to measure marginal and internal fit using images captured with both an optical microscope and a smartphone camera, comparing the fit measurement performance of these devices and analyzing their correlation. Working casts (with 10 posterior and 10 anterior teeth) created to fabricate fixed dental prostheses were used. These working casts were scanned using a desktop scanner (E1) to design an interim crown, and the designed interim crown was fabricated using a three-dimensional (3D) printer. Utilizing the silicone replica technique, the fabricated interim crown replicated the fit, which was then captured using both an optical microscope and a smartphone camera. The captured images were used to measure the marginal and internal fit according to the imaging device. Intraclass correlation coefficients (ICC) were used for reliability analysis according to the imaging device. Furthermore, the Wilcoxon signed-rank test was adopted for the comparative evaluation of the marginal and internal fit between the imaging devices (α = 0.05). The measurement results of the marginal and internal fit according to the optical microscope and smartphone camera did exhibit a significant difference (P < 0.05). The ICC between the two devices showed an "excellent" agreement of over 0.9 at all measurement points (P < 0.001). A smartphone camera could be used to obtain images for evaluating the marginal and internal fit.


Assuntos
Prótese Dentária , Smartphone , Correlação de Dados , Estudos de Viabilidade , Reprodutibilidade dos Testes
2.
BMC Oral Health ; 24(1): 355, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38504246

RESUMO

BACKGROUND: In partial edentulous individuals, a partial removable dental prosthesis (PRDP) is a common dental replacement option to improve oral function and quality of life. However, some patients discontinue using their denture over time. The aim of this study was to determine the prevalence and characteristics of partial edentulous patients who no longer wear their dentures, explore their reasons, and assess their oral health-related quality of life (OHRQoL). METHODOLOGY: This cross-sectional study, conducted at Chulalongkorn University Dental School from 2013 to 2019, involved patients who received PRDP treatment. They were contacted via phone calls and asked about their denture usage. Eligible participants were patients who had stopped or rarely used their PRDPs. Data on oral status, health insurance, and PRDP variables were collected from hospital records. Telephone interviews were conducted to collect the initial reasons for seeking PRDP treatment, reasons for discontinuation, desire for a new PRDP, and OHRQoL. The Oral Impacts on Daily Performances index was used to assess the OHRQoL. The score was dichotomized into the absence or presence of oral impacts. Chi-square tests and multivariable binary logistic regression were employed to determine the associations between oral impacts and various factors in the participants who discontinued PRDP usage. RESULTS: Among the 975 contacted participants, 175 (17.9%) discontinued using their PRDPs. Most of these individuals had at least 20 remaining natural teeth and/or 4 posterior occluding pairs. The primary initial reason for seeking PRDP treatment was often based on a dentist's suggestion. Although many participants reported no impact on OHRQoL and did not express the need for new PRDPs, those experiencing oral impacts were more likely to seek replacements. CONCLUSIONS: With up to 7 years follow-up duration, individuals with partial edentulism and sufficient remaining functional dentition without oral impacts were more inclined to discontinue PRDP usage. Those with maxillary anterior teeth loss were less likely to discontinue using their PRDP. The primary initial reason for seeking PRDP treatment was often a dentists' suggestion. However, the individuals reporting oral impacts expressed their needs for new denture replacements. This highlights the significance of incorporating patient needs and preferences in prosthodontic decision-making.


Assuntos
Prótese Dentária , Prótese Parcial Removível , Boca Edêntula , Perda de Dente , Humanos , Qualidade de Vida , Estudos Transversais , Seguimentos , Saúde Bucal
3.
Int J Prosthodont ; 37(1): 109, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38381993

RESUMO

PURPOSE: To compare the marginal and internal fit of monolithic zirconia (MZ) 3-unit fixed dental prostheses (FDPs) fabricated using two CAD/CAM workflows: full-chairside (FCH) and lab (LAB). MATERIALS AND METHODS: The right maxillary first premolar and first molar were prepared for MZ 3-unit FDPs on a typodont. CEREC Primescan digitized the typodont model 15 Omes. A total of 30 FDPs was fabricated using two processes: FCH (n = 15) and LAB (n = 15). FCH and LAB FDPs were designed using CEREC SW 4.5.1 and Exocad and milled using CEREC MC X and Zirkonzhan 600/V3, respectively. A fast-sintering protocol was used in both groups. A dual-scan technique was used to assess the cement space at the occlusal surface (OC), axial wall (AX), and margin (MA). Statistical analysis of the results was performed using univariate ANOVA with Scheff. post hoc test (a = .05). RESULTS: Measurements in the FCH and LAB groups were within the clinically acceptable marginal and internal fit. The fit of FCH FDPs at MA, AX, and OC was 77.50 ± 29.99 µm, 99.67 ± 21.58 µm, and 150.03 ± 30.78 µm, respectively. The fit of LAB FDPs at MA, AX, and OC was 100.27 ± 27.06 µm, 116.53 ± 17.90 µm, and 142.30 ± 19.00 µm, respectively. The difference between the two groups was not statistically significant. CONCLUSIONS: MZ 3-unit FDPs fabricated using FCH have clinically acceptable marginal and internal fit. This result verifies the ability of FCH workflow to fabricate MZ mulOunit FDPs in a single visit.


Assuntos
Planejamento de Prótese Dentária , Prótese Dentária , Planejamento de Prótese Dentária/métodos , Adaptação Marginal Dentária , Zircônio , Cimentos Dentários , Desenho Assistido por Computador
4.
J Pak Med Assoc ; 74(2): 247-251, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38419221

RESUMO

Objectives: To determine the frequency and extent of artefacts in magnetic resonance imaging and/or computed tomography scans of head caused by fixed dental prosthesis. METHODS: The retrospective study was conducted at Aga Khan University Hospital from July to December 2021, and comprised magnetic resonance imaging and/or computed tomography scans from January 2015 to December 2020 of the head of individuals with existing fixed dental prosthetic work at the time of exposure. They were analysed for the presence of artefacts. The association between artefacts and the presence of fixed dental prosthesis was explored. Data was analysed using SPSS 23. RESULTS: Of the 297 images evaluated, 173 (58%) were magnetic resonance imaging scans, and 124(42%) were computed tomography scans. The most common artefacts was grade I 148(49.8%), followed by grade II 140(47.1%) and grade III 9(3%). There was no significant association between fixed dental prosthesis and the artefacts (p>0.05). Conclusion: There should be no reservations in placing fixed metal prosthesis in individuals on account of future brain scans.


Assuntos
Artefatos , Prótese Dentária , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodos
5.
J Prosthet Dent ; 131(4): 708.e1-708.e8, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38383280

RESUMO

STATEMENT OF PROBLEM: Removable dental prostheses require periodic relining with the loss of intaglio surface fit because of mucosal shape changes over time. Therefore, a new material with high adaptability to tissue changes over time would be beneficial. PURPOSE: This study focused on a shape-memory gel (SMG) that softens when heated, retains its shape when cooled, and returns to its original shape when reheated. The purpose was to optimize SMG for intraoral use by controlling the ratio of 2 acrylate monomers and to evaluate the changes in the shape memory and physical properties of SMG with temperature and to evaluate biocompatibility. MATERIAL AND METHODS: SMG specimens were synthesized using the following mixing ratios of 2 monomers, docosyl acrylate (DA) and stearyl acrylate (SA): 0:100, 25:75, 50:50, 75:25, and 100:0. SMG specimens were photopolymerized using a fluorescent light-polymerizing unit. To evaluate shape memory as a function of temperature, permanent deformation was measured based on the standardized compression set test for thermoplastic rubber. For evaluation of the physical properties and cytotoxicity, a 3-dimensionally printed denture base material was used as the control material. All assessments were compared between the groups by using 1-way analysis of variance followed by the Tukey-Kramer multiple comparison test (α=.05). RESULTS: SMGs with a higher amount of DA maintained their compressed shape at room and intraoral temperatures. However, the SMG matrices softened and recovered their original shapes above 60 °C. SMGs showed Shore A hardness equivalent to that of the denture-base polymer material at intraoral temperatures because of the high phase-transition temperature. The low water solubility of SMGs supported the biocompatibility test results. CONCLUSIONS: SMG, in which the phase-transition temperature was controlled by mixing acrylate monomers with different melting points, exhibited shape memory in the intraoral environment. The results indicate the feasibility of applying SMG for the fabrication of removable dental prostheses because of its high adaptability to tissue changes over time and biocompatibility.


Assuntos
Acrilatos , Prótese Dentária , Temperatura , Temperatura de Transição , Teste de Materiais
6.
Dent Mater J ; 43(2): 235-246, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38417861

RESUMO

Prosthetic biomaterials can affect the composition of the subgingival microbiota and consequently the production of proinflammatory cytokines, causing damage to the periodontium. A total of 40 patients were divided into two groups: 20 with monolithic zirconia (MZ) prostheses and 20 with porcelain fused to metal (PFM) with nickel-chromium (Ni-Cr) alloy prostheses. Subgingival plaque and gingival crevicular fluid samples were taken. The Checkerboard technique for DNA-DNA hybridization and the enzyme-linked immunosorbent assay technique were performed. Teeth with MZ presented a lower percentage of bleeding on probing and tooth mobility compared to teeth with PFM with Ni-Cr alloy. Prosthodontic teeth harbored higher total levels of the 18 bacterial species than non-prosthodontic teeth. There was a higher prevalence of S. gordonii and V. parvula species in PFM with Ni-Cr alloy compared to MZ. There was an increase in IL-1ß, TNF-α and CX3CL1 levels in PFM with Ni-Cr alloy compared to MZ. MZ is a candidate biomaterial with fewer negative effects on the periodontium, allowing for longer prostheses longevity in the mouth.


Assuntos
Prótese Dentária , Microbiota , Humanos , Líquido do Sulco Gengival , Fator de Necrose Tumoral alfa , Ligas de Cromo , Porcelana Dentária , DNA , Quimiocina CX3CL1
7.
J Mech Behav Biomed Mater ; 151: 106395, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38244420

RESUMO

OBJECTIVES: To assess the mechanical durability of monolithic zirconia implant-supported fixed dental prostheses (iFDP) design on one implant, with a distal and a mesial extension cantilever bonded to a titanium base compared to established designs on two implants. MATERIALS AND METHODS: Roxolid Tissue level (TL), and tissue level x (TLX) implants were used to manufacture screw-retained 3-unit iFDPs (n = 60, n = 10 per group), with following configurations (X: Cantilever; I: Implant, T: Test group, C: Control group): T1: X-I-X (TL); T2: X-I-X (TLX); T3: I-I-X (TL); T4: I-I-X (TLX); C1: I-X-I (TL); C2: I-X-I (TLX). The iFDPs were thermomechanically aged and subsequently loaded until fracture using a universal testing machine. The failure load at first crack (Finitial) and at catastrophic fracture (Fmax) were measured and statistical evaluation was performed using two-way ANOVA and Tukey's post-hoc tests. RESULTS: The mean values ranged between 190 ± 73 and 510 ± 459 N for Finitial groups, and between 468 ± 76 and 1579 ± 249 N for Fmax, respectively. Regarding Finitial, neither the implant type, nor the iFDP configuration significantly influenced measured failure loads (all p > 0.05). The choice of implant type did not show any significant effect (p > 0.05), while reconstruction design significantly affected Fmax data (I-I-Xa < X-I-Xb < I-X-Ic) (p < 0.05). The mesial and distal extension groups (X-I-X) showed fractures only at the cantilever extension site, while the distal extension group (I-I-X) showed one abutment and one connector fracture at the implant/reconstruction interface. CONCLUSION: Results suggest that iFDPs with I-X-I design can be recommended regardless of tested implant type followed by the mesial and distal extension design on one implant abutment (X-I-X).


Assuntos
Implantes Dentários , Prótese Dentária , Zircônio , Suporte de Carga , Parafusos Ósseos , Análise de Variância , Titânio , Falha de Restauração Dentária , Análise do Estresse Dentário , Teste de Materiais , Coroas
8.
Dent Mater ; 40(2): 198-209, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37951752

RESUMO

OBJECTIVES: To investigate the 5-year intraoral evolution and kinetics of low-temperature degradation (LTD) of second-generation monolithic prostheses made of 3% molar yttrium-doped tetragonal zirconia polycrystal (3Y-TZP) and the influence of masticatory mechanical stresses and glaze layer on this evolution. METHODS: A total of 101 posterior tooth elements were included in this prospective clinical study, which comprised ex vivo LTD monitoring (at baseline, 6 months, 1 year, 2 years, 3 years, and 5 years) using Raman spectroscopy (n = 2640 monoclinic phase measurement points per evaluation time) and scanning electron microscopy (SEM). Four types of areas (1-2 mm2 surface, six on molars, and four on premolars) were analysed on each element surface: occlusal, axial, glazed, or unglazed. Raman mapping, high-resolution SEM, and focused ion beam-SEM were performed on selected samples. RESULTS: The dental prostheses developed a tetragonal-to-monoclinic transformation at the extreme surface of the material after six months in a buccal environment, and this process increased significantly over time. Over the five years of monitoring, the transformation developed nonuniformly with the presence of localised clusters of monoclinic grains. Tribological stresses generate grain pull-out from these clusters, which may raise questions regarding the release of 3Y-TZP nanoparticles into the body. The prosthesis fracture rate was 4.5% after 5 years. SIGNIFICANCE: LTD developed in vivo on the surfaces of 3Y-TZP dental prostheses and progressed slowly but significantly over time, up to 5 years investigation. However, the effects of aging on the failure rate recorded and of zirconia nanoparticles released into the body require further investigation.


Assuntos
Prótese Dentária , Zircônio , Temperatura , Estudos Prospectivos , Propriedades de Superfície , Zircônio/química , Ítrio/química , Teste de Materiais , Materiais Dentários/química , Cerâmica/química
9.
Int J Legal Med ; 138(2): 685-691, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37347275

RESUMO

Access to better health care anticipates that more medical devices can be found alongside skeletal remains. Those employed in oral rehabilitation, with available brands or batch/series, can prove useful in the identification process. A previous study in the Colecção de Esqueletos Identificados Século XXI described macroscopically the dental prostheses. An unusual case of a dental device with chromatic alterations demonstrated to require a more detailed analysis. The individual, a 53-year-old male, exhibited, at both arches, a fixed tooth-supported rehabilitation, with gold colouring classified initially as a gold-palladium alloy. Simultaneously, a green pigmentation deposit was observable in bone and prosthesis. This investigation aimed to verify the elemental composition of the dental prosthesis alloy. Elemental analysis was performed by X-ray fluorescence in two regions (labial surface of the prosthetic crown and the root surface of the lower right lateral incisor). Both the spectra and the qualitative results found higher levels of copper and aluminium, followed by nickel, iron, zinc, and manganese. No gold or palladium was detected. The most probable assumption is that a copper-aluminium alloy was used, as its elemental concentration corresponds to those measured in similar devices. Dental prostheses of copper-aluminium alloys have been made popular since the 1980s, particularly in the USA, Japan, and Eastern Europe. Apart from the biographical information, it was also known that the individual's place of birth was an Eastern European country, which highlighted the usefulness of this type of information when dealing with missing people cases.


Assuntos
Prótese Dentária , Paládio , Masculino , Humanos , Pessoa de Meia-Idade , Raios X , Portugal , Paládio/análise , Cobre/análise , Alumínio/análise , Fluorescência , Incisivo , Ligas de Ouro/análise
10.
Odontology ; 112(1): 169-176, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37422770

RESUMO

The aim of this study is to evaluate the effect of pre-ceramic soldering on the marginal and internal fit of 4-unit zirconia fixed dental prostheses (FPDs) that have two abutments and two pontics. 4-unit zirconia frameworks (Zirkonzahn ICE Translucent) (Z Group) and monolithic zirconia (Zirkonzahn Prettau) (M Group) FPDs were manufactured. Groups were divided into two groups (n = 10) control (ZC and MC) and soldering (ZS and MS). Samples of ZS and MS groups were cut into two pieces under cooling water and soldered with a bonding material (DCM Zircon HotBond). The marginal and internal fit of the restorations were measured from 36 points of each sample and cement space volume was calculated using reverse engineering software (Geomagic Design X). The mean and standard deviations were submitted to Generalized Linear Mixed Model (GLMM) analysis (α = 0.05). Statistical differences between groups before and after pre-ceramic soldering on point measurements were found. In total cement spacing measurements, a significant difference was found amongst all groups (P < 0.05). However, in premolars, a statistically significant difference was found between ZC and ZS groups and MC and MS groups (P < 0.05). All discrepancies after pre-ceramic soldering were found to be lower than before.


Assuntos
Porcelana Dentária , Prótese Dentária , Porcelana Dentária/química , Cerâmica/química , Materiais Dentários/química , Zircônio/química , Cimentos Dentários , Cimentos de Ionômeros de Vidro , Adaptação Marginal Dentária , Prótese Parcial Fixa , Desenho Assistido por Computador
11.
Artigo em Inglês | MEDLINE | ID: mdl-37552175

RESUMO

The present study assessed the impact of a fixed prosthetic rehabilitation on masticatory function in patients diagnosed with stage IV periodontitis. Eligible participants were adults in need of complex rehabilitation due to masticatory dysfunction. Masticatory function was evaluated using the two-colored chewing gum mixing ability test (VOH) at the diagnostic phase (T0), 1 week after delivery of the prosthetic prototype (T1), and 1 week after delivery of the final prosthetic solution (T2). Ten subjects were treated with a fixed prosthesis following periodontal and implant surgery using an individualized, fully digital workflow. Full-mouth plaque and bleeding scores, pocket depth, and clinical attachment level improved significantly. VOH was 0.472 ± 0.168 at T0, 0.358 ± 0.166 at T1, and 0.250 ± 0.123 at T2. A significant improvement in VOH was observed from T0 to T1 (difference: -0.114; 95% CI: -0.199 to -0.029; P = .014) and from T1 to T2 (difference: -0.108; 95% CI: -0.200 to -0.015; P = .027). From T0 to T2, VOH increased by 44.3%. Self-perceived assessment of masticatory function also improved from T0 to T2 (P = .002). The fixed prosthetic rehabilitation in patients with stage IV periodontitis allowed for a significant improvement in objective and subjective measurements of masticatory function.


Assuntos
Prótese Dentária , Mastigação , Periodontite , Adulto , Humanos
12.
J Prosthet Dent ; 131(2): 330.e1-330.e9, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37993321

RESUMO

STATEMENT OF PROBLEM: Prostheses printed on a 3-dimensional (3D) printer need to undergo the postpolymerization process, which can increase the working time. However, it has been not suggested for reducing workload and improving the properties of prostheses in dental clinical practice. PURPOSE: The purpose of this in vitro study was to evaluate how the printing temperature impacts the dimensional accuracy and fracture load of 3D printed fixed dental prostheses (FDPs). MATERIAL AND METHODS: Dental prostheses were printed at room temperature (RT), 50°C, and 70°C using a stereolithography 3D printer. Subsequently, after rinsing away residual monomer, the printed parts underwent the green condition (it was not subjected to any postprocessing) and postpolymerization. The mechanical properties of the printed FDPs were determined by loading to fracture (n=6). To evaluate their clinical applicability, the dimensional accuracy and fit of FDPs fabricated at various resin polymerization temperatures were measured (n=6). The 1-way analysis of variance was used to perform statistical comparisons, followed by the Tukey honestly significant difference test (α=.05). RESULTS: The specimens printed at RT and 50°C were better than those printed at 70°C in terms of dimensional accuracy and fit (P<.05). Nonetheless, the dimensional accuracy and fit of the specimens printed at 70°C were clinically acceptable. The fracture load of the 3-unit FDPs depended significantly on the printing temperature. CONCLUSIONS: The dimensional accuracy and fracture load of the 70°C group were acceptable for FDP fabrication. Thus, the temperature of 70°C without postprocessing may help make the procedure more efficient.


Assuntos
Prótese Dentária , Estereolitografia , Temperatura , Desenho Assistido por Computador , Polimerização , Teste de Materiais , Impressão Tridimensional
13.
Laryngoscope ; 134(5): 2331-2334, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37916852

RESUMO

In this case report, 60-year-old patient who aspirated total dental prosthesis into the postcricoid region was presented with patient's history, clinical findings, radiologic examinations and surgical treatment with comparison of literature data. To our literature knowledge, this is the first total dental prosthesis detected in postcricoid region. This was unusual because it did not cause any respiratory disorders such as laryngospasm and asphyxia, although it led to mucosal abrasions in a wide area of esophageus. Laryngoscope, 134:2331-2334, 2024.


Assuntos
Prótese Dentária , Corpos Estranhos , Laringe , Humanos , Pessoa de Meia-Idade , Laringoscopia , Corpos Estranhos/cirurgia , Radiografia , Prótese Dentária/efeitos adversos
14.
J Dent ; 141: 104806, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38154701

RESUMO

OBJECTIVE: This review investigated the current literature pertaining to the repairability of computer-aided design-computer-aided manufacturing (CAD-CAM) milled and three-dimensional (3D) printed resin-based dental prostheses (RBDPs) as well as the appropriate surface treatment for each repair material that will produce adequate repair bond strength. DATA/SOURCES: PubMed, Web of Science, and Scopus databases were searched for published articles involving repair of CAD-CAM RBDPs between January 2010 and June 2023. Data were collected and analyzed to reveal the surface treatment effects, suggested repair materials, and strength of repaired RBDPs. STUDY SELECTION: Out of 164 retrieved titles, 11 studies were included, of which five investigated the repair of 3D-printed RBDPs, three investigated the repair of CAD-CAM milled resins, and three investigated both materials. Additionally, of the included studies, seven investigated denture base resins, three studied provisional restoration resins, and one evaluated 3D-printed intraoral splints. Various surface treatments were suggested, with air-abrasive methods being the most commonly used. Different materials for resin repair were proposed and used, including auto-polymerized, reline, and composite resins. For 3D-printed resins, repair with Bis-acrylic/Bis-GMA composites improved repair strength. CONCLUSION: Surface treatments positively affected the repair strength of conventional and milled RBDPs. However, challenges remain relevant to the repair of 3D-printed resins owing to composition mismatches and fabrication techniques. Therefore, further investigation is required to develop new 3D-printed resins. CLINICAL SIGNIFICANCE: CAD-CAM milled resins have satisfactory repair strength, which increases with surface treatment. The repair of 3D-printed resins has proven challenging even with surface treatments. However, composite resins are the materials of choice.


Assuntos
Resinas Compostas , Prótese Dentária , Teste de Materiais , Desenho Assistido por Computador , Polimetil Metacrilato , Bis-Fenol A-Glicidil Metacrilato , Propriedades de Superfície
15.
Braz. dent. sci ; 27(2): 1-12, 2024. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1551332

RESUMO

Objective: In response to the demand for dental implants, extensive research has been conducted on methods for transferring load to the surrounding bone. This study aimed to evaluate the stresses on the peripheral bone, implants, and prostheses under scenarios involving of the following variables: prosthesis designs, vertical bone heights, load angles, and restorative materials. Material and Methods: Three implants were inserted in the premolar and molar regions (5-6-7) of the two mandibular models. Model 1 represented 0 mm marginal bone loss and Model 2 simulated 3 mm bone loss. CAD/CAM-supported materials, hybrid ceramic (HC), resin-nano ceramic (RNC), lithium disilicate (LiSi), zirconia (Zr), and two prosthesis designs (splinted and non-splinted) were used for the implant-supported crowns. Forces were applied vertically (90°) to the central fossa and buccal cusps and obliquely (30°) to the buccal cusps only. The stresses were evaluated using a three-dimensional Finite Element Analysis. Results: Oblique loading resulted in the highest stress values. Of the four materials, RNC showed the low stress in the restoration, particularly in the marginal area. The use of different restorative materials did not affect stress distribution in the surrounding bone. The splinted prostheses generated lower stress magnitude on the bone, and while more stress on the implants were observed. Conclusion: In terms of the stress distribution on the peri-implant bone and implants, the use of different restorative materials is not important. Oblique loading resulted in higher stress values, and the splinted prosthesis design resulted in lower stress (AU)


Objetivo: Em resposta à demanda por implantes dentários, extensa pesquisa foi realizada sobre métodos para transferir carga ao osso circundante. Este estudo buscou avaliar os estresses no osso periférico, implantes e próteses em cenários que envolvem as seguintes variáveis: designs de próteses, alturas ósseas verticais, ângulos de carga e materiais restauradores. Material e Métodos: Três implantes foram inseridos nas regiões dos pré-molares e molares (5-6-7) de dois modelos de mandíbula. O Modelo 1 representou perda óssea marginal de 0 mm e o Modelo 2 simulou perda óssea de 3 mm. Materiais suportados por CAD/CAM, cerâmica híbrida (HC), cerâmica nano-resina (RNC), dissilicato de lítio (LiSi), zircônia (Zr) e dois designs de próteses (sintetizadas e não-sintetizadas) foram utilizados para as coroas suportadas por implantes. Forças foram aplicadas verticalmente (90°) à fossa central e cúspides bucais e obliquamente (30°) apenas às cúspides bucais. Os estresses foram avaliados usando Análise de Elementos Finitos tridimensional. Resultados: Cargas oblíquas resultaram nos valores mais altos de estresse. Entre os quatro materiais, RNC mostrou baixo estresse na restauração, especialmente na área marginal. O uso de diferentes materiais restauradores não afetou a distribuição de estresse no osso circundante. Próteses sintetizadas geraram menor magnitude de estresse no osso, enquanto mais estresse nos implantes foi observado. Conclusão: Em termos de distribuição de estresse no osso peri-implantar e implantes, o uso de diferentes materiais restauradores não é crucial. Cargas oblíquas resultaram em valores mais altos de estresse, e o design de prótese sintetizada resultou em menor estresse. (AU)


Assuntos
Implantes Dentários , Prótese Dentária , Análise de Elementos Finitos , Fenômenos Biomecânicos
16.
Pesqui. bras. odontopediatria clín. integr ; 24: e210105, 2024. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1529143

RESUMO

Abstract Objective: To evaluate the utility of panoramic radiographs in pre-prosthetic screening of edentulous arches. Material and Methods: Panoramic radiographs taken for three years were retrospectively analyzed. Observations from the radiographs shall be categorized and classified into either of the two categories, namely: 'findings with minimal impact on denture fabrication' and 'findings which affect denture fabrication and require further evaluation.' Anatomic variations, jaw pathologies, and residual ridge resorption patterns were assessed. Results: This study included the initial screening of 23,020 panoramic radiographs, out of which 505 (showing either one or both edentulous arches) were included for the study purpose. The age range of the subjects was from 21 to 94 years. 52.6% of the radiographs showed positive findings. More than half of the radiographs belonged to the males (52.5%). Hyperpneumatization of the maxillary sinus, crestal position of the mental foramen, and retained root fragments were the most common entities noted in the radiographs. Changes in the mental foramen were significantly higher in males than females (p=0.002). Conclusion: Observations from this study showed that panoramic radiographs have high utility for screening edentulous arches, and they should be used in routine clinical practice before denture fabrication.


Assuntos
Radiografia Panorâmica/instrumentação , Programas de Rastreamento , Prótese Dentária , Arcada Osseodentária/diagnóstico por imagem , Distribuição de Qui-Quadrado , Estudos Retrospectivos
17.
Braz. j. oral sci ; 23: e243318, 2024. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1532568

RESUMO

Aim: This study aimed to investigate the relationship between self-perceived oral health and the prosthetic status of individuals who seek care in prosthodontics clinics. Methods: Self-perceived oral health was analyzed through the Geriatric Oral Health Assessment Index (GOHAI). Abutment tooth mobility was assessed, and denture status was determined by clinical assessment of stability, retention, occlusal balance, vertical dimension, and integrity of dentures. The frequency of individuals in each variable was determined for the low and very low GOHAI conditions. Chi-square, Pearson, and stepwise logistic regression tests were used for the statistical analyses (α = 0.05). Results: Ninety wearers of removable dentures with a mean age of 55.1±9.1 years were evaluated. None of the variables was related to GOHAI values (p > 0.05). The regression analysis showed that age predicts (p = 0.006) the variation of GOHAI conditions (OR = 0.924, CI = 0.873- 0.978), showing only 7.6% protective effect against very low GOHAI. Unsatisfactory stability showed the opposite effect (p = 0.034) and the individuals with this characteristic are more likely (OR = 3.055) to have very low GOHAI scores (CI = 1.085- 8.602). Conclusions: The self-perceived oral health of wearers of removable dentures worsens with age and unsatisfactory stability of dentures


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Reabilitação , Autoimagem , Saúde Bucal , Prótese Dentária
18.
Braz. dent. sci ; 27(1): 1-8, 2024. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1554218

RESUMO

Objective: The aim of this study was to evaluate the marginal gap of frameworks produced using the CAD-CAM system, from zirconia and lithium disilicate blocks, adapted to a tooth preparation and a gypsum die. Material and Methods: For this study, a human first molar tooth was used as a master model with a full crown preparation. It was molded 20 times to obtain the gypsum die and randomly divided into 2 groups (n=10) for the fabrication of zirconia and lithium disilicate frameworks. The frameworks were made using pre-sintered zirconia blocks and lithium disilicate blocks, both CAD-CAM systems. The marginal gap was measured in µm at four points (buccal, palatal, mesial, and distal) using a comparator microscope with 30x magnification, with the framework seated on the master model (tooth), and on the gypsum die. Marginal gap data (µm) were evaluated using two-way analysis of variance and Tukey's test with a significance level of 5%. Results: The results showed that there was no statistically significant interaction between the factors studied (p=0.223) or isolated factors (ceramic factor p=0.886 and die factor p=0.786). Conclusion: Both ceramics produced using the CAD-CAM technique did not exhibit statistical differences in marginal adaptation on the two types of substrates, both on tooth preparation and on the gypsum die (AU)


Objetivo: O objetivo deste estudo foi avaliar o espaço marginal de estruturas produzidas usando o sistema CAD-CAM, a partir de blocos de zircônia e dissilicato de lítio, adaptadas a um preparo sobre dente e a um troquel de gesso. Material e Métodos: Para este estudo, um dente molar humano foi utilizado como modelo mestre com preparo para coroa total. Este foi moldado 20 vezes para obter o troquel de gesso e dividido aleatoriamente em 2 grupos (n=10) para a fabricação de estruturas de zircônia e dissilicato de lítio. As estruturas foram feitas usando blocos de zircônia pré-sinterizados e blocos de dissilicato de lítio, ambos sistemas para CAD-CAM. O espaço marginal foi medido em µm, em quatro pontos (bucal, palatal, mesial e distal), utilizando um microscópio comparador com ×30 de ampliação e com a estrutura assentada no modelo mestre (dente) e no troquel de gesso. Os dados de espaço marginal (µm) foram avaliados usando análise de variância bidirecional e teste de Tukey com um nível de significância de 5%. Resultados: Os resultados mostraram que não houve interação estatisticamente significativa entre os fatores estudados (p=0,223) ou isoladamente (fator cerâmica p=0,886 e fator troquel p=0,786). Conclusão: Ambas as cerâmicas produzidas usando a técnica CAD-CAM não apresentaram diferenças estatísticas em relação à adaptação marginal nos dois tipos de substratos, tanto na preparação dentária quanto no troquel de gesso(AU)


Assuntos
Prótese Dentária , Desenho Assistido por Computador , Adaptação Marginal Dentária , Porcelana Dentária
19.
São José dos Campos; s.n; 2024. 73 p. ilus, tab.
Tese em Português | BBO - Odontologia | ID: biblio-1553188

RESUMO

Este estudo avalia o comportamento em fadiga e distribuição de tensões de três desenhos de preparo para overlays (n=21) (com preparo de istmo [IST], com preparo não retentivo [nRET] e sem preparo de istmo [sIST]) e o efeito do material restaurador (resina composta [Tetric CAD] e cerâmica vítrea reforçada por leucita [Empress CAD]) cimentados sobre resina epóxi G10. Com o objetivo de determinar os perfis de carregamento para o ensaio de vida acelerado step-stress (SSALT)), três espécimes de cada grupo foram testados monotônicamente, e os demais foram ensaiados até a fratura, em uma máquina de simulação de mastigação. O número de ciclos e a respectiva carga em que cada espécime falhou foi utilizado para análise de sobrevivência, assim como os dados de espécimes sobreviventes ao teste. Foi realizada a análise de probabilidade Weibull. O modo de falha dos espécimes foi avaliado por estereomicroscopia e microscopia eletrônica de varredura. O comportamento biomecânico foi avaliado utilizando a análise por elementos finitos, e a distribuição de tensão foi avaliada considerando os modelos isotrópicos, linearmente elásticos e homogêneos; uma carga axial (200 N) foi aplicada à superfície oclusal dos molares. A concentração de tensão nas restaurações, interfaces adesivas e estrutura dental foi analisada pelo critério de Tensão Máxima Principal. Houve diferença estatística no SSALT entre nRET-RC (1840,46N) e os demais grupos de estudo, no FEA os grupos LEU absorveram maiores picos de tensão e RC os menores. Os diferentes desenhos de preparo para overlay influenciam a resistência à fratura e a distribuição de tensões em restaurações de cerâmica reforçada com leucita e resina composta para CAD/CAM.(AU)


This study assessed the fatigue behavior and stress distribution of three preparation designs for overlays (n=21) (with isthmus preparation [IST], with non-retentive preparation [nRET], and without isthmus preparation [sIST]) and the effect of the restorative material (composite resin [Tetric CAD] and leucite-reinforced glass ceramic [Empress CAD]) cemented on G10 epoxy resin. To determine the loading profiles for the step-stress accelerated life test (SSALT), three specimens from each group were tested monotonically, and the remainder were tested until fracture, in a chewing simulation machine. The number of cycles and the corresponding load at which each specimen failed were used for survival analysis, along with data from surviving specimens. Weibull probability analysis was performed. The failure mode of the specimens was evaluated through stereomicroscopy and scanning electron microscopy. Biomechanical behavior was assessed using finite element analysis, and stress distribution was evaluated considering isotropic, linearly elastic, and homogeneous models; an axial load (200 N) was applied to the occlusal surface of the molars. Stress concentration in restorations, adhesive interfaces, and dental structure was analyzed using the Maximum Principal Stress criterion. There was a statistical difference in SSALT between nRET-RC (1840.46N) and the other study groups. In FEA, the LEU groups absorbed higher stress peaks, and RC groups absorbed lower ones. The different preparation designs for overlays influence the fracture resistance and stress distribution in leucite-reinforced ceramic and composite resin restorations for CAD/CAM.(AU)


Assuntos
Estresse Mecânico , Prótese Dentária , Análise de Elementos Finitos
20.
Clin Oral Investig ; 28(1): 17, 2023 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-38135856

RESUMO

OBJECTIVES: To investigate the association between access and delivery of complete dental prosthesis according to the proportion of the black population in Brazilian municipalities and to oral health policies. MATERIALS AND METHODS: Ecological data from 2017 to 2021 relating to the delivery of complete dentures stratified by race was collected in all Brazilian cities. We calculated a racial inequality indicator by subtracting the percentage of the black population from the percentage of complete dental prostheses that were delivered to blacks in each municipality. Logistic and linear regression models were carried out. RESULTS: We found that 49.2% (2737) of municipalities delivered complete prostheses. The service was more frequently available in municipalities where black individuals made up 20-80% (odds ratio [OR] = 1.45, 95% confidence interval [CI] 1.15; 1.81), those with dental specialty centers (DSC) (OR = 3.04, 95%CI 2.50; 3.68), and those with more oral health teams (OHTs) (OR = 3.43, 95%CI 2.81; 4.18). Where dental prostheses were available, racial inequities favored the white population by 7.7 percentage points (p < 0.01). Increased inequality was observed in municipalities with more OHTs and/or a higher proportion of black individuals (>80%). CONCLUSIONS: Although municipalities with a DSC, and with more OHTs offer better access to complete dental prosthesis for blacks, racial inequality still impacts the delivery of the service. Primary and secondary healthcare services may even exacerbate this. CLINICAL RELEVANCE: Policymakers should monitor racial inequities in healthcare services. The currently unmet needs of black people are critical, especially in cities with more OHTs and/or increased proportions of black people.


Assuntos
Prótese Dentária , Saúde Bucal , Humanos , Brasil , Modelos Lineares
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...