Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 614
Filtrar
1.
J Orthop Surg Res ; 16(1): 679, 2021 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-34794457

RESUMO

BACKGROUND: Total hip arthroplasty (THA) with ceramic-on-ceramic (CoC) was created to minimise wear debris and aseptic loosening. A decade ago, a meta-analysis showed a 10-year survival rate of just 89%. Based on the excellent tribology of the current CoC, significant improvement of implant survivorship is expected. In patients younger than 60, we conducted a meta-analysis to assess 10-year survival and complications after using current primary CoC THA. MATERIALS AND METHODS: PubMed, Scopus, EMBASE, Virtual Health Library, and Cochrane Library were used to scan for published trials that met the inclusion criteria until January 2019. The qualified studies were subjected to a systematic review and proportional analysis, and the randomised controlled trials (RCTs) were included in a comparison meta-analysis. RESULTS: Thirteen studies were included 156 findings. The total number of hips was 2278. Nine studies were cohort, and four were RCTs between ceramic and polyethylene cups. The analysis revealed an average age of 44 years (range 24-54). The 10-year survival 96% (95% CI; 95.4-96.8%), aseptic loosening rate 0.516. (95% CI; 0.265-0.903), ceramic fracture rate 0.620 (95% CI; 0.34-1.034) and squeaking rate 2.687 (95% CI; 1.279-4.593). A comparison meta-analysis revealed the risk ratio (RR) for revision was 0.27 (95% CI; 0.15-0.47), and for aseptic loosening 0.15 (0.03-0.70) favouring CoC, while RR for component fracture was 1.62 (95% CI; 0.27-9.66) favouring the polyethylene. CONCLUSION: In patients under sixty, current CoC THAs are correlated with better 10-year outcomes than before and have high survivorship rates. LEVEL OF EVIDENCE: Level I.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Fatores Etários , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Artroplastia de Quadril/estatística & dados numéricos , Cerâmica , Articulação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Prótese de Quadril/estatística & dados numéricos , Humanos , Artropatias/cirurgia , Desenho de Prótese , Falha de Prótese/tendências , Ensaios Clínicos Controlados Aleatórios como Assunto
2.
Sci Rep ; 11(1): 21763, 2021 11 05.
Artigo em Inglês | MEDLINE | ID: mdl-34741121

RESUMO

The aim of the study was to analyse the results of uncemented total hip replacement, using the Metha (metaphyseal) stem. A total of 158 patients (70 females and 88 males) were qualified to the study and submitted to total hip arthroplasty (183 procedures altogether), using the Metha stem. The mean age of the patients on the day of surgery was 51.7 years (the range from 17 to 69 years). The mean follow up period was 9.2 years (the range from 5 to 13.5 years). Preoperative assessments gave poor scores, according to the Merle d'Aubigne and Postel classification, modified by Charnley. The average improvement after surgery, according to the used scale, was 6.9 points. A very good outcome was recorded in 154 cases (84.2%), a good outcome was achieved in 20 cases (10.9%) and a poor outcome was confirmed in 9 cases, while no satisfactory case was observed. Poor outcomes were associated with implant loosening. Extraskeletal ossification was noted in 10 cases (5.5%). According to the Kaplan-Meier estimator, the 10-year survival was 93.2% and 97.3% for the whole implant and the stem alone, respectively. 1. Our follow-up period of more than 9 years on the average, indicates that Metha stems produce excellent clinical and functional results in operated young patients with advanced degenerative changes of the hip joint. 2. Assuming a proper qualification for the procedure, the absence of complications and a correct surgical technique, which is slightly more difficult, when compared to standard stem implantation, the risk of aseptic loosening is fairly negligible.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril/estatística & dados numéricos , Adolescente , Adulto , Idoso , Artroplastia de Quadril/estatística & dados numéricos , Artroplastia de Quadril/tendências , Humanos , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos , Adulto Jovem
3.
J Mater Sci Mater Med ; 32(9): 123, 2021 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-34524578

RESUMO

INTRODUCTION: Recurrent dislocations are still the most frequent reason for revision in total hip arthroplasty (THA). The impact of bearing surfaces on dislocations is still controversial. We hypothesized that: (1) bearing surfaces influence the revisions due to dislocations; (2) ceramic-on-ceramic reduced the revisions for dislocations in adjusted models; (3) Delta-on-Delta bearings reduced the revisions for dislocations in comparison to surfaces with cross-linked polyethylene. MATERIALS AND METHODS: The regional arthroplasty registry was enquired about bearing surfaces and revisions for dislocations and instability. Unadjusted and adjusted rates were provided, including sex, age (<65 years or ≥65 years), head diameter (≤28 mm or >28 mm; <36 mm or ≥36 mm) as variables. 44,065 THAs were included. RESULTS: The rate of revisions for dislocations was significantly lower in ceramic-on-ceramic and metal-on-metal bearings (unadjusted rates). After adjusting for age, sex, and head size (36 and 28 mm), hard-on-hard bearings were protective (p < 0.05): ceramic-on-ceramic had a lower risk of revisions due to dislocation than ceramic-on-polyethylene (HR 1.6, 95% CI 1.2-2.2 p = 0.0009). The rate of revisions for dislocation was similar in bearings with cross-linked polyethylene and Delta-on-Delta articulations, in unadjusted and adjusted models. CONCLUSION: Bearings with conventional polyethylene were more predisposed to dislocations. Currently adopted bearings exerted no significant influence on revisions due to dislocations. These findings could be primarily related to wear, but due to the time distribution, soft tissue envelopes and surface tension may also play a role. Pre-clinical biomechanical evaluations and prospective matched cohort studies are required to draw definitive conclusions.


Assuntos
Artroplastia de Quadril , Desenho de Prótese , Falha de Prótese , Reoperação , Suporte de Carga/fisiologia , Idoso , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/estatística & dados numéricos , Análise de Falha de Equipamento , Feminino , Prótese de Quadril/efeitos adversos , Prótese de Quadril/estatística & dados numéricos , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Desenho de Prótese/efeitos adversos , Sistema de Registros , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Risco , Propriedades de Superfície , Resultado do Tratamento
4.
Sci Rep ; 11(1): 15851, 2021 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-34349160

RESUMO

The long-term success of highly effective total hip arthroplasty (THA) is mainly restricted by aseptic loosening, which is widely associated with friction between the head and cup liner. However, knowledge of the in vivo joint friction and resulting temperature increase is limited. Employing a novel combination of in vivo and in silico technologies, we analyzed the hypothesis that the intraoperatively defined implant orientation defines the individual joint roofing, friction and its associated temperature increase. A total of 38,000 in vivo activity trials from a special group of 10 subjects with instrumented THA implants with an identical material combination were analyzed and showed a significant link between implant orientation, joint kinematics, joint roofing and friction-induced temperature increase but surprisingly not with acting joint contact force magnitude. This combined in vivo and in silico analysis revealed that cup placement in relation to the stem is key to the in vivo joint friction and heating-up of THA. Thus, intraoperative placement, and not only articulating materials, should be the focus of further improvements, especially for young and more active patients.


Assuntos
Artroplastia de Quadril/métodos , Fricção , Calefação , Articulação do Quadril/fisiopatologia , Articulação do Quadril/cirurgia , Prótese de Quadril/estatística & dados numéricos , Idoso , Artroplastia de Quadril/instrumentação , Feminino , Humanos , Masculino , Fenômenos Mecânicos , Pessoa de Meia-Idade , Desenho de Prótese
5.
JAMA Netw Open ; 4(6): e2110687, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-34076699

RESUMO

Importance: The worldwide population is aging and includes more female individuals than male individuals, with higher rates of total hip arthroplasty (THA) among female individuals. Although research on this topic has been limited to date, several studies are currently under way. Objectives: To evaluate the association between sex and 2-year revision after THA. Design, Setting, and Participants: This cohort study used data from statewide databases in New York and California between October 1, 2015, and December 31, 2018. Patients 18 years or older with osteoarthritis who underwent THA and had sex recorded in the database were included in the analysis. Exposure: Total hip arthroplasty. Main Outcomes and Measures: The outcome of interest was the difference in early, all-cause revision surgery rates after primary THA between women and men. The association of sex with the revision rate was examined using Cox proportional hazards regression analysis. Results: Of 132 826 patients included in the study, 74 002 (55.7%) were women; the mean (SD) age was 65.9 (11.0) years, and the median follow-up time was 1.3 years (range, 0.0-3.0 years). The 2-year revision rate was 2.5% (95% CI, 2.4%-2.6%) among women and 2.1% (95% CI, 2.0%-2.2%) among men. After adjusting for demographic characteristics, comorbidities, and facility volume, a minimal clinically meaningful difference was observed in revision rates despite women having a higher risk of all-cause revision compared with men (hazard ratio, 1.16; 95% CI, 1.07-1.26; P < .001). The risk of revision was increased among women compared with men in the subgroup of patients who were younger than 55 years (hazard ratio, 1.47; 95% CI, 1.20-1.81; P < .001). Conclusions and Relevance: In this cohort study, no clinically meaningful difference in all-cause revision rates after primary THA was found between men and women at 2-year follow-up. The modest difference in the risk of revision between men and women in a small subgroup of patients younger than 55 years suggests that the risk of revision in this population should be studied further.


Assuntos
Artroplastia de Quadril/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Falha de Prótese/etiologia , Reoperação/estatística & dados numéricos , Adulto , Idoso , Estudos de Coortes , Feminino , Prótese de Quadril/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco , Fatores de Risco , Distribuição por Sexo , Fatores Sexuais , Resultado do Tratamento , Estados Unidos
6.
Sci Rep ; 11(1): 10073, 2021 05 12.
Artigo em Inglês | MEDLINE | ID: mdl-33980984

RESUMO

Hip joint loads need careful consideration during postoperative physiotherapy after joint replacement. One factor influencing joint loads is the choice of footwear, but it remains unclear which footwear is favorable. The objective of the present study was to investigate the influence of footwear on hip joint loads in vivo. Instrumented hip endoprostheses were used for in vivo load measurements. The parameters resultant contact force (Fres), bending moment (Mbend) and torsional moment (Mtors) were evaluated during treadmill walking at 4 km/h with different shoe types. In general, footwear tended to increase hip joint loading, with the barefoot shoe having the least influence. Fres and Mbend were significantly increased during heel strike for all shoe types in comparison to barefoot walking, with everyday shoe (34.6%; p = 0.028 and 47%; p = 0.028, respectively) and men's shoe (33.2%; p = 0.043 and 41.1%; p = 0.043, respectively) resulting in the highest changes. Mtors at AbsMax was increased by all shoes except for the barefoot shoe, with the highest changes for men's shoe (+ 17.6%, p = 0.043) and the shoe with stiffened sole (+ 17.5%, p = 0.08). Shoes, especially those with stiff soles or elaborate cuishing and guiding elements, increase hip joint loads during walking. The influence on peak loads is higher for Mtors than for Fres and Mbend. For patients in which a reduction of hip joints loads is desired, e.g. during physiotherapy after recent surgery or to alleviate symptoms of osteoarthritis, low profile shoes with a flexible sole may be preferred over shoes with a stiff sole or elaborate cushioning elements.


Assuntos
Artroplastia de Quadril/métodos , Marcha , Articulação do Quadril/fisiologia , Prótese de Quadril/estatística & dados numéricos , Osteoartrite do Joelho/cirurgia , Sapatos/normas , Caminhada , Idoso , Fenômenos Biomecânicos , Feminino , Calcanhar , Humanos , Masculino , Pessoa de Meia-Idade
7.
J Bone Joint Surg Am ; 103(14): 1303-1311, 2021 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-33999875

RESUMO

BACKGROUND: The BIRMINGHAM HIP Resurfacing (BHR) system is a metal-on-metal hip implant system approved by the U.S. Food and Drug Administration in 2006. The approval required a multicenter, prospective, post-market-approval study. Our purpose is to report the current results at 10 years of follow-up. METHODS: Between October 2006 and December 2009, 280 primary BHR procedures were performed at 5 sites. Outcome measures included Kaplan-Meier survivorship, reasons for revision, radiographic component stability and osteolysis, Harris hip scores, and metal levels including cobalt and chromium. The mean age at the time of the procedure was 51.3 ± 7.1 years, 74% (206) of 280 BHRs were implanted in male patients, the mean body mass index was 27.8 ± 4.4 kg/m2, and 95% (265) of 280 hips had a primary diagnosis of osteoarthritis. The mean follow-up among all 280 hips was 9.0 ± 2.5 years. Prior to 10-year follow-up, 20 hips were revised and 5 patients representing 5 hips had died. Among the remaining 255 hips, 218 (85%) met the minimum follow-up of 10 years. RESULTS: The 10-year survival free from all-cause component revision was 92.9% (95% confidence interval [CI], 89.8% to 96.1%) for all hips and 96.0% (95% CI, 93.1% to 98.9%) among male patients <65 years old at the time of the procedure. Reasons for revision included femoral loosening (n = 5), femoral neck fracture (n = 3), pseudotumor (n = 3), osteolysis (n = 2), and acetabular loosening (n = 1), as well as 6 revisions for a combination of pain, noise, or metal levels. Among unrevised hips, the median Harris hip score improved from preoperatively (59) to 1 year postoperatively (99; p < 0.001) and remained stable through 10 years postoperatively (99; p = 0.08). Radiographically, 5% (10) of 218 unrevised hips had osteolysis with no component migration. Median metal levels had increased at 1 year postoperatively (cobalt: from 0.12 ppb preoperatively to 1.5 ppb at 1 year postoperatively, p < 0.001; chromium: from 0.6 ppb preoperatively to 1.7 ppb at 1 year postoperatively, p < 0.001), then remained stable through 5 years before slightly decreasing at 10 years postoperatively (cobalt: 1.3 ppb, p < 0.001; chromium: 1.4 ppb, p < 0.001). CONCLUSIONS: This prospective, multicenter, post-market-approval study demonstrated that the BHR implant system is safe and effective through 10 years of follow-up, particularly among young male patients. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril/efeitos adversos , Próteses Articulares Metal-Metal/efeitos adversos , Osteoartrite do Quadril/cirurgia , Falha de Prótese , Adulto , Idoso , Artroplastia de Quadril/efeitos adversos , Aprovação de Equipamentos , Feminino , Seguimentos , Prótese de Quadril/estatística & dados numéricos , Humanos , Masculino , Próteses Articulares Metal-Metal/estatística & dados numéricos , Pessoa de Meia-Idade , Estudos Prospectivos , Reoperação/estatística & dados numéricos , Resultado do Tratamento , Estados Unidos , United States Food and Drug Administration , Adulto Jovem
8.
Sci Rep ; 11(1): 7578, 2021 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-33828113

RESUMO

This study aimed to investigate the accuracy of cup placement and determine the predictive risk factors for inaccurate cup positioning in robot-assisted total hip arthroplasty (THA). We retrospectively analyzed 115 patients who underwent robot-assisted THA between August 2018 and November 2019. Acetabular cup alignment and three-dimensional (3D) position were measured using pre- or postoperative computed tomography (CT) data. Absolute differences in cup inclination, anteversion, and 3D position were assessed, and their relation to preoperative factors was evaluated. The average measurement of the absolute differences was 1.8° ± 2.0° (inclination) and 1.9° ± 2.3° (anteversion). The average absolute difference in the 3D cup position was 1.1 ± 1.2 mm (coronal plane) and 0.9 ± 1.0 mm (axial plane). Multivariate analysis revealed that a posterior pelvic tilt [odds ratio (OR, 1.1; 95% confidence interval (CI), 1.00-1.23] and anterior surgical approach (OR, 5.1; 95% CI, 1.69-15.38) were predictive factors for inaccurate cup positioning with robot-assisted THA. This is the first study to demonstrate the predictive risk factors (posterior pelvic tilt and anterior surgical approach) for inaccurate cup position in robot-assisted THA.


Assuntos
Artroplastia de Quadril/métodos , Prótese de Quadril , Procedimentos Cirúrgicos Robóticos/métodos , Idoso , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Estudos de Coortes , Feminino , Prótese de Quadril/estatística & dados numéricos , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/instrumentação , Sistemas de Navegação Cirúrgica , Tomografia Computadorizada por Raios X
9.
Tumori ; 107(6): NP41-NP44, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33629653

RESUMO

OBJECTIVE: To outline a practical method of performing prostate cancer radiotherapy in patients with bilateral metal hip prostheses with the standard resources available in a modern general hospital. The proposed workflow is based exclusively on magnetic resonance imaging (MRI) to avoid computed tomography (CT) artifacts. CASE DESCRIPTION: This study concerns a 73-year-old man with bilateral hip prostheses with an elevated risk prostate cancer. Magnetic resonance images with assigned electron densities were used for planning purposes, generating a synthetic CT (sCT). Imaging acquisition was performed with an optimized Dixon sequence on a 1.5T MRI scanner. The images were contoured by autosegmentation software, based on an MRI database of 20 patients. The sCT was generated assigning averaged electron densities to each contour. Two volumetric modulated arc therapy plans, a complete arc and a partial one, where the beam entrances through the prostheses were avoided for about 50° on both sides, were compared. The feasibility of matching daily cone beam CT (CBCT) with MRI reference images was also tested by visual evaluations of different radiation oncologists. CONCLUSIONS: The use of magnetic resonance images improved accuracy in targets and organs at risk (OARs) contouring. The complete arc plan was chosen because of 10% lower mean and maximum doses to prostheses with the same planning target volume coverage and OAR sparing. The image quality of the match between performed CBCTs and MRI was considered acceptable. The proposed method seems promising to improve radiotherapy treatments for this complex category of patients.


Assuntos
Radioterapia com Íons Pesados/normas , Prótese de Quadril/estatística & dados numéricos , Imageamento por Ressonância Magnética/métodos , Próteses Articulares Metal-Metal/estatística & dados numéricos , Neoplasias da Próstata/patologia , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia Guiada por Imagem/métodos , Idoso , Artefatos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Órgãos em Risco , Neoplasias da Próstata/radioterapia
10.
J Artif Organs ; 24(2): 234-242, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33449228

RESUMO

We evaluated the clinical and radiographic outcomes of femoral head penetration and total hip arthroplasties with untreated and poly (2-methacryloyloxyethyl phosphorylcholine) (PMPC)-grafted highly cross-linked polyethylene (HXLPE) acetabular liners against 26-, 28-, and 32-mm cobalt-chromium alloy femoral heads 3 years after the index surgery. Three combinations of the articulating surfaces were evaluated in the present study: untreated or PMPC-grafted HXLPE liner against 26- or 28-mm femoral heads (n = 16, 24) [control (26 or 28 mm) and PMPC (26 or 28 mm)] and PMPC-grafted HXLPE liner against 32-mm femoral heads (n = 64) [PMPC (32 mm)]. The clinical outcomes improved at 3 years postoperatively for the groups. No periprosthetic osteolysis or acetabular component migration was detected, and no revision surgery was performed among the groups. The steady-state wear rate of the PMPC (26 or 28 mm) group (0.021 mm/year) was lower than that of the control (26 or 28 mm) group (- 0.015 mm/year); the steady-state wear was under the clinical threshold. In contrast, the steady-state wear rate of the PMPC (32 mm) group (-0.006 mm/year) showed no significant difference when compared to that of the PMPC (26 or 28 mm) group (p < 0.01). The results obtained in the present study clearly demonstrate that PMPC-grafting onto an HXLPE surface improved the wear resistance of acetabular liners, even when coupled with larger femoral heads. Although further follow-up evaluations are required, PMPC-grafted HXLPE acetabular liners may be a promising approach to extend the longevity of artificial joints.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Fosforilcolina/análogos & derivados , Polietileno/química , Ácidos Polimetacrílicos/química , Desenho de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Artroplastia de Quadril/estatística & dados numéricos , Análise de Falha de Equipamento , Feminino , Cabeça do Fêmur/química , Cabeça do Fêmur/cirurgia , Seguimentos , Prótese de Quadril/efeitos adversos , Prótese de Quadril/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Fosforilcolina/química , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Falha de Prótese/etiologia , Reoperação/estatística & dados numéricos , Resultado do Tratamento
11.
Acta Orthop ; 92(1): 36-39, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33172317

RESUMO

Background and purpose - Dislocation is one of the most frequent reasons for cup revision after total hip arthroplasty (THA) for an acute fracture. A dual mobility cup (DMC) might reduce this risk. We determined the cup revision rate after THA for an acute fracture according to type of cup.Patients and methods - All THAs for an acute fracture registered in the Dutch Arthroplasty Register (LROI) during 2007-2019 were included (n = 11,857). Type of cup was divided into DMC and unipolar cup (UC). Competing risk analyses were performed with cup revision for any reason as endpoint. Multivariable Cox regression analyses with outcome cup revision were performed adjusted for sex, age, ASA class, and surgical approach, stratified for UC THA with femoral head size of 32 mm and 22-28 mm.Results - A DMC was used in 1,122 (9%) hips. The overall 5-year cup revision rate for any reason after THA for acute fracture was 1.9% (95% CI 1.6-2.2). Cup revision for dislocation within 5 years was performed in 1 of 6 DMC THAs versus 108 of 185 (58%) UC THAs. Univariable Cox regression analyses showed no statistically significant difference in cup revision rate between DMC and UC (HR = 0.8; CI 0.4-1.5). Multivariable Cox regression analyses showed lower risk of cup revision in DMC THA (n = 1,122) compared with UC THA with 22-28 mm femoral head size (n = 2,727) (HR = 0.4; CI 0.2-0.8).Interpretation - The 5-year cup cumulative incidence of revision after THA for acute fracture was comparable for DMC and UC THA. However, DMC THA had a lower risk of cup revision than UC THA with 22-28 mm femoral head.


Assuntos
Artroplastia de Quadril , Fraturas do Quadril/cirurgia , Prótese de Quadril/estatística & dados numéricos , Desenho de Prótese/estatística & dados numéricos , Falha de Prótese , Reoperação/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Feminino , Fraturas do Quadril/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia
12.
Acta Orthop ; 92(1): 15-22, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33167753

RESUMO

Background and purpose - Collaborations between arthroplasty registries are important in order to create the possibility of detecting inferior implants early and improve our understanding of differences between nations in terms of indications and outcomes. In this registry study we compared patient and procedure characteristics, and revision rates in the Nordic Arthroplasty Register Association (NARA) database and the Dutch Arthroplasty Register (LROI).Patients and methods - All total hip arthroplasties (THAs) performed in 2010-2016 were included from the LROI (n = 184,862) and the NARA database (n = 290,823), which contains data from Denmark, Norway, Sweden, and Finland. Descriptive statistics and Kaplan-Meier survival analyses based on all reasons for revision and stratified by fixation were performed and compared between countries.Results - In the Netherlands, the proportion of patients aged < 55 years (9%) and male patients (34%) was lower than in Nordic countries (< 55 years 11-13%; males 35-43%); the proportion of osteoarthritis (OA) (87%) was higher compared with Sweden (81%), Norway (77%), and Denmark (81%) but comparable to Finland (86%). Uncemented fixation was used in 62% of patients in the Netherlands, in 70% of patients in Denmark and Finland, and in 28% and 19% in Norway and Sweden, respectively. The 5-year revision rate for THAs for OA was lower in Sweden (2.3%, 95% CI 2.1-2.5) than in the Netherlands (3.0%, CI 2.9-3.1), Norway (3.8%, CI 3.6-4.0), Denmark (4.6%, CI 4.4-4.8), and Finland (4.4%, CI 4.3-4.5). Revision rates in Denmark, Norway, and Finland were higher for all fixation groups.Interpretation - Patient and THA procedure characteristics as well as revision rates evinced some differences between the Netherlands and the Nordic countries. The Netherlands compared best with Denmark in terms of patient and procedure characteristics, but resembled Sweden more in terms of short-term revision risk. Combining data from registries like LROI and the NARA collaboration is feasible and might possibly enable tracking of potential outlier implants.


Assuntos
Artroplastia de Quadril/estatística & dados numéricos , Prótese de Quadril/estatística & dados numéricos , Reoperação/estatística & dados numéricos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Padrões de Prática Médica , Países Escandinavos e Nórdicos
13.
J Mater Sci Mater Med ; 31(7): 56, 2020 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-32594253

RESUMO

INTRODUCTION: Ceramic-on-ceramic couplings demonstrated to be reliable bearings in primary total hip arthroplasty (THA), with long-term remarkable results. Like-on-like configurations were widely described. On the contrary, mixed material combinations from the same manufacturer, Delta-on-Forte or Forte-on-Delta, were poorly studied. In particular, it is unknown whether mixed ceramic combinations are more at risk of ceramic fractures. Thus, a registry study was conducted to investigate the long-term survival rates and reasons for revision of mixed ceramic combinations. A comparison with Delta-on-Delta couplings was also performed. MATERIALS AND METHODS: The regional arthroplasty registry RIPO was enquired about three cohorts of ceramic bearings (head-on-liner: Delta-on-Forte, Forte-on-Delta, Delta-on-Delta). Demographics, survival rates and reasons for revision were evaluated and compared. RESULTS: In total, 346 (1.5%) implants had a Delta-on-Forte coupling (mean follow-up: 6.4 years). In total, 1163 (5%) THAs had a Forte-on-Delta articulation (mean follow-up: 8.2 years). Delta-on-Delta surfaces were implanted in 21,874 (93.5%) hips (mean follow-up: 3.9 years). Mixed material combinations were implanted between 2003 and 2007. The survival rates of the three cohorts were similar and were higher than 95% at 10 years. In Forte-on-Delta group, four liners failed (0.3% of the implants), whereas ceramic fractures occurred in 15 cases (0.1%) in Delta-on-Delta couplings (3 heads and 12 liners). Considering ceramic fracture as endpoint, there was no significant difference between the three survival rates. CONCLUSIONS: Mixed ceramic bearing configurations from the same manufacturer in primary THA showed mid-to-longterm dependable outcomes, not inferior to the most recent like-on-like ceramic bearings. No additional risks of ceramic fractures were evident. Thus, closer follow-ups are not required.


Assuntos
Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Cerâmica/química , Prótese de Quadril , Idoso , Artroplastia de Quadril/estatística & dados numéricos , Cerâmica/uso terapêutico , Estudos de Coortes , Análise de Falha de Equipamento/estatística & dados numéricos , Feminino , Seguimentos , Articulação do Quadril/fisiopatologia , Articulação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Prótese de Quadril/estatística & dados numéricos , Humanos , Masculino , Próteses Articulares Metal-Metal/efeitos adversos , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Reoperação , Resultado do Tratamento
14.
Acta Orthop ; 91(4): 378-382, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32285731

RESUMO

Background and purpose - Whole-blood (WB) chromium (Cr) and cobalt (Co) measurements are vital in the follow-up of metal-on-metal total hip replacement (MoM THR) patients. We examined whether there is a substantial change in repeated WB, Co, and Cr levels in patients with bilateral ReCap-M2A-Magnum THR. We also specified the number of patients exceeding the safe upper limit (SUL) of WB Co and Cr in the repeated measurement.Patients and methods - We identified 141 patients with bilateral ReCap-M2A-Magnum THR operated in our institution. 61 patients had repeated WB metal ion measurements with bilateral MoM implants still in situ in the second measurement. The mean time elapsing from the first measurement (initial measurement) to the second (control measurement) was 1.9 years (SD = 0.6, range 0.2-3.5). We used earlier established SUL levels for bilateral implants by Van Der Straeten et al. (2013).Results - The median (range) Co and Cr values decreased in the repeated measurement from 2.7 (0.6-25) to 2.1 (0.5-21) and 2.6 (0.8-14) to 2.1 (0.5-18) respectively. In 13% of the patients Co levels exceeded the SUL in the initial measurement and the proportion remained constant, at 13%, in the repeated measurement. In 5% of the patients, Cr levels were above SUL in the initial measurement and an equal 5% in the control measurement.Interpretation - Repeated WB metal ion levels did not increase in patients with bilateral ReCap-M2A-Magnum THR with a mean 1.9-year measurement interval. Long-term development of WB metal ion levels is still unclear in these patients.


Assuntos
Artroplastia de Quadril , Cromo/sangue , Cobalto/sangue , Prótese de Quadril , Próteses Articulares Metal-Metal , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/estatística & dados numéricos , Feminino , Prótese de Quadril/efeitos adversos , Prótese de Quadril/estatística & dados numéricos , Humanos , Masculino , Próteses Articulares Metal-Metal/efeitos adversos , Próteses Articulares Metal-Metal/estatística & dados numéricos , Pessoa de Meia-Idade , Fatores de Tempo
15.
Acta Orthop ; 91(4): 401-407, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32285736

RESUMO

Background and purpose - 32-mm heads are widely used in total hip arthroplasty (THA) in Scandinavia, while the proportion of 36-mm heads is increasing as they are expected to increase THA stability. We investigated whether the use of 36-mm heads in THA after proximal femur fracture (PFF) is associated with a lower risk of revision compared with 32-mm heads.Patients and methods - We included 5,030 patients operated with THA due to PFF with 32- or 36-mm heads from the Nordic Arthroplasty Register Association database. Each patient with a 36-mm head was matched with a patient with a 32-mm head, using propensity score. The patients were operated between 2006 and 2016, with a metal or ceramic head on a polyethylene bearing. Cox proportional hazards models were fitted to estimate the unadjusted and adjusted hazard ratio (HR) with 95% confidence intervals (CI) for revision for any reason and revision due to dislocation for 36-mm heads compared with 32-mm heads.Results - 36-mm heads had an HR of 0.9 (CI 0.7-1.2) for revision for any reason and 0.8 (CI 0.5-1.3) for revision due to dislocation compared with 32-mm heads at a median follow-up of 2.5 years (interquartile range 1-4.4).Interpretation - We were not able to demonstrate any clinically relevant reduction of the risk of THA revision for any reason or due to dislocation when 36-mm heads were used versus 32-mm. Residual confounding due to lack of data on patient comorbidities and body mass index could bias our results.


Assuntos
Artroplastia de Quadril/efeitos adversos , Fraturas do Fêmur/cirurgia , Prótese de Quadril , Reoperação/estatística & dados numéricos , Idoso , Artroplastia de Quadril/métodos , Artroplastia de Quadril/estatística & dados numéricos , Feminino , Prótese de Quadril/efeitos adversos , Prótese de Quadril/estatística & dados numéricos , Humanos , Estimativa de Kaplan-Meier , Masculino , Modelos de Riscos Proporcionais , Falha de Prótese , Fatores de Risco , Fatores de Tempo
16.
Arch Orthop Trauma Surg ; 140(4): 563-573, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31974695

RESUMO

INTRODUCTION: Few studies evaluated clinical benefits of pre-operative templating in total hip arthroplasty (THA). We investigated whether mismatch between planned and real implant sizes and medio-lateral offsets compromises THA outcomes. MATERIALS AND METHODS: We reviewed records of 184 primary THAs with pre-operative CT scans used for templating. Acetabular offset (AO), femoral offset (FO) and global offset (GO) were measured on pre-operative CT scans, during acetate templating, and post-operative antero-posterior radiographs. Multivariable analyses were performed to determine if Forgotten Joint Score (FJS) and Oxford Hip Score (OHS) at > 2 years were associated with differences between post-operative and planned parameters. RESULTS: The FJS and OHS were not influenced by mismatch of component sizes nor of FO and GO. The FJS was better when the post-operative AO was greater than planned (p = 0.050). The FJS differed among arthritic types (p = 0.015). Multivariable analyses confirmed that older patients had better OHS (beta - 0.16; p = 0.033) and FJS (beta 0.74; p = 0.002), medialized hips had worse FJS (beta - 20.1; p = 0.041) and hips with greater AO than planned had better FJS (beta 1.71; p = 0.024) CONCLUSIONS: Implanting a component of different size than planned did not compromise THA outcomes, but medialized hips had worse scores, and conservative acetabular reaming improved scores.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Cuidados Pré-Operatórios , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Artroplastia de Quadril/estatística & dados numéricos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Prótese de Quadril/estatística & dados numéricos , Humanos , Cuidados Pré-Operatórios/efeitos adversos , Cuidados Pré-Operatórios/métodos , Cuidados Pré-Operatórios/estatística & dados numéricos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
17.
Bone Joint J ; 102-B(1): 90-101, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31888362

RESUMO

AIMS: The aim of this study was to identify the effect of the manufacturing characteristics of polyethylene acetabular liners on the survival of cementless and hybrid total hip arthroplasty (THA). METHODS: Prospective cohort study using linked National Joint Registry (NJR) and manufacturer data. The primary endpoint was revision for aseptic loosening. Cox proportional hazard regression was the primary analytical approach. Manufacturing variables included resin type, crosslinking radiation dose, terminal sterilization method, terminal sterilization radiation dose, stabilization treatment, total radiation dose, packaging, and face asymmetry. Total radiation dose was further divided into G1 (no radiation), G2 (> 0 Mrad to < 5 Mrad), G3 (≥ 5 Mrad to < 10 Mrad), and G4 (≥ 10 Mrad). RESULTS: A total of 5,329 THAs were revised, 1,290 of which were due to aseptic loosening. Total radiation dose, face asymmetry, and stabilization treatments were found to significantly affect implant survival. G1 had the highest revision risk for any reason and for aseptic loosening and G3 and G4 the lowest. Compared with G1, the adjusted hazard ratio for G2 was 0.74 (95% confidence interval (CI) 0.64 to 0.86), G3 was 0.36 (95% CI 0.30 to 0.43), and G4 was 0.38 (95% CI 0.31 to 0.47). The cumulative incidence of revision for aseptic loosening at 12 years was 0.52 and 0.54 per 100 THAs for G3 and G4, respectively, compared with 1.95 per 100 THAs in G1. Asymmetrical liners had a lower revision risk due to aseptic loosening and reasons other than aseptic loosening compared with symmetric (flat) liners. In G3 and G4, stabilization with vitamin E and heating above melting point performed best. CONCLUSION: Polyethylene liners with a total radiation dose of ≥ 5 Mrad, an asymmetrical liner face, and stabilization with heating above the melting point demonstrate best survival. Cite this article: Bone Joint J 2020;102-B(1):90-101.


Assuntos
Artroplastia de Quadril/normas , Prótese de Quadril/normas , Polietileno , Adulto , Idoso , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/estatística & dados numéricos , Tecnologia Biomédica , Feminino , Prótese de Quadril/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese/normas , Desenho de Prótese/estatística & dados numéricos , Falha de Prótese , Reoperação/estatística & dados numéricos , Fatores de Risco
18.
Arch Orthop Trauma Surg ; 140(3): 415-424, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31960168

RESUMO

PURPOSE: The management of acetabular bone loss is a challenging problem in revision total hip arthroplasty (rTHA). The aim of this systematic review is to summarize and critically analyze indications, complications, clinical and radiological outcomes of custom-made acetabular components in rTHA. METHODS: A systematic review of English literature was performed on Medline. Retrospective or prospective studies with minimum 2 years of follow-up (FU) were included. The PRISMA 2009 flowchart and checklist were considered to edit the review. Rates of intra- or post-operative complications, aseptic loosening (AL), periprosthetic joint infection (PJI), reoperations and re-revisions rates were extrapolated. RESULTS: 18 articles with a level of evidence of IV were included. Six hundred and thirty-four acetabular custom components (627 patients) with a mean FU of 58.6 ± 29.8 months were analyzed. The studies showed good clinical and functional outcomes. Custom-made acetabular components allowed a stable fixation with 94.0 ± 5.0% survival rate. The estimated rate of re-operations and re-revisions were 19.3 ± 17.3% and 5.2 ± 4.7%, respectively. The incidence of PJI was 4.0 ± 3.9%. CONCLUSIONS: The acetabular custom-made implants represent a reliable solution for pelvic discontinuity and particular cases of bone loss classified as Paprosky Type IIIA-B or type III-IV according to American Academy of Orthopaedic Surgeons system where the feature of the defect cannot be handled with standard implants. This strategy allows to fit the implant to the residual host bone, bypassing the bony deficiency and restoring hip biomechanics. Satisfactory clinical and radiological outcomes at mid-term follow-up are reported in literature.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/estatística & dados numéricos , Prótese de Quadril/efeitos adversos , Prótese de Quadril/estatística & dados numéricos , Humanos , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese , Reoperação/estatística & dados numéricos
19.
Arch Orthop Trauma Surg ; 140(1): 121-127, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31655879

RESUMO

BACKGROUND: The magnitude and pattern of acceptable long-term migration of cementless femoral stems are not well understood. The Corail hydroxyapatite-coated cementless stem is a clinically successful and commonly used femoral stem with a long-term migration pattern not previously described in the literature. The aim of this study was to assess the long-term migration of the Corail hydroxyapatite-coated cementless stem using radiostereometric analysis (RSA) at 14-year follow-up, thereby establishing a benchmark acceptable long-term migration pattern for hydroxyapatite-coated cementless prostheses. MATERIALS AND METHODS: A prospective cohort of 29 patients (30 hips) undergoing primary total hip arthroplasty for primary hip osteoarthritis were enrolled into a study to characterise the migration of the Corail cementless stem. A total of 13 patients (4 males, 9 females) with mean age 82 (range 68-92) underwent repeat RSA radiographs at minimum 10 years post-operation (mean 13.9 years, range 13.3-14.4). Subsidence of the stem was measured and compared to prior measurements taken at 6 months and 1, 2, and 6 years. RESULTS: None of the 13 patients have been revised. The migration at 6 months, 1 year, 2 years, and 6 years has been previously recorded. At mean 14-year follow-up, the cohort mean subsidence of the cementless stem was 0.70 mm (range - 0.06 to 3.61 mm). For each stem followed up at 6 months and 14 years, the mean subsidence over this period was 0.05 mm (range - 0.14 to 0.57 mm). There is no significant difference in mean subsidence at 6 months and 14 years (p = 0.43). CONCLUSIONS: The long-term pattern of the subsidence of the Corail femoral stem has not previously been described. Subsidence occurs within the first 6 months, after which there is persistent stabilisation of the implant to 14 years. This study provides a description of a long-term acceptable migration pattern to which new hydroxyapatite-coated cementless prostheses may be compared. LEVEL OF EVIDENCE: II.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/estatística & dados numéricos , Durapatita , Feminino , Fêmur , Seguimentos , Quadril/diagnóstico por imagem , Quadril/fisiologia , Prótese de Quadril/efeitos adversos , Prótese de Quadril/estatística & dados numéricos , Humanos , Masculino , Falha de Prótese , Análise Radioestereométrica
20.
Biomed Tech (Berl) ; 65(4): 477-484, 2020 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-31834858

RESUMO

Threaded cups show good clinical results when implanted correctly. In clinical use, multiple cases with an incomplete placement of the EcoFit threaded cup (implantcast) were observed. This behaviour could not be explained intra- and postoperatively. The aim of this study was to compare and optimise the drill-in-behaviour of the EcoFit cup in a biomechanical investigation. EcoFit cup sizes 46, 50 and 54 mm were compared with the SC cup (Aesculap) size 50 mm. Foam blocks (Sawbones) of density 0.16 g/ml (pcf 10), 0.32 g/ml (pcf 20) and 0.48 g/ml (pcf 30) were used. After standardised placement using a universal testing system (n = 8 per group), the primary stability, the overhang of the cups and the drill-in behaviour were measured. Overreamings of 1 and 2 mm were performed (pcf 20, n = 8) for the EcoFit cup size 50 and the primary stability as well as the overhang measurements were examined. Measurements of the cup diameter, thread depth and thread pitch were performed on three-dimensional (3D) images of the cup size 50 mm. The drill-in behaviour was different between the EcoFit and the SC cups. Even with maximum torque, the EcoFit cup could not be positioned as deep as the SC cup in standard reaming conditions (overhang of 1.1 ± 0.4 mm for the EcoFit size 50 in pcf 20 and of -0.01 ± 0.2 mm for the SC cup). The primary stability was lower for the EcoFit cup in comparison to the SC cup (128.8 ± 3.2 Nm vs. 138.6 ± 9.1 Nm, p = 0.0291). With overreaming to 51 mm, a deeper positioning of the EcoFit was possible (overlap of -0.3 ± 0.1, comparable to the SC cup). The overreaming of the cavity also led to a significantly higher primary stability of 143.4 ± 3.7 Nm (p < 0.001) comparable to the unaltered condition (128.8 ± 3.2 Nm). Overreaming to 52 mm had no further advantage in terms of primary stability or overhang. The geometric measurements showed significant differences as well. The previously clinically observed difficulties in inserting the cup were confirmed by this study. By overreaming to 51 mm, the drill-in behaviour, the primary stability and the measured overhang were comparable to the reference cup. The obtained results suggest that the extension of the acetabulum cavity to 51 mm while using the implantcast EcoFit size 50 should be implemented in clinical applications.


Assuntos
Acetábulo/cirurgia , Acetábulo/fisiopatologia , Artroplastia de Quadril/métodos , Fenômenos Biomecânicos , Prótese de Quadril/estatística & dados numéricos , Humanos , Torque
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...