Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Acta Diabetol ; 57(10): 1151-1157, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32300875

RESUMO

AIMS: Intraoperative complications in cataract surgery are more common in diabetic patients. Solving aphakia in these circumstances remains a challenge, as the scleral structure has been shown to be different in diabetes. This study aims to analyze the role of a secondary sutureless scleral intraocular lens (IOL) flanged fixation in diabetic patients without capsular support and to compare the anatomical and functional outcomes using a 30 gauge (G) ultrathin wall needle vs. a 27G needle. METHODS: Retrospective, observational cohort study. 105 eyes (105 patients) who underwent PPV with secondary IOL fixation using a sutureless 27G (n = 51) or a 30G ultrathin wall (UTW) needle technique (n = 54) and had a 24 months postoperative follow up. Consecutive patients' records were reviewed for lens stability and centration parameters, intra- and postoperative complications at 7 days, 1, 3, 6, 12, and 24 months after surgery. Correlations between outcome measures and needle size (27G vs. 30G UTW) were analyzed. RESULTS: IOL displacement occurred in 30 patients (41.2%) in the 27G group and did not occur in the 30G UTW needle group (p < 0.001). Mean time until IOL displacement was 10.5 ± 7.0 months (range: 7 days-24 months). IOL centricity was significantly better in the 30G ultrathin wall needle group compared to 27 G (p = 0.001). Additional surgical interventions were necessary only in the 27G group (n = 14). CONCLUSIONS: Sutureless IOL flanged technique using a 30G UTW needle is more predictable and has less complications in aphakic diabetic patients, compared to a 27G needle technique.


Assuntos
Diabetes Mellitus/cirurgia , Retinopatia Diabética/cirurgia , Implante de Lente Intraocular/instrumentação , Agulhas , Procedimentos Cirúrgicos sem Sutura/instrumentação , Adulto , Idoso , Afacia/epidemiologia , Afacia/cirurgia , Argentina/epidemiologia , Estudos de Coortes , Diabetes Mellitus/epidemiologia , Retinopatia Diabética/epidemiologia , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Implante de Lente Intraocular/efeitos adversos , Implante de Lente Intraocular/métodos , Lentes Intraoculares , Masculino , Pessoa de Meia-Idade , Agulhas/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Esclera/cirurgia , Procedimentos Cirúrgicos sem Sutura/efeitos adversos , Procedimentos Cirúrgicos sem Sutura/métodos , Acuidade Visual
2.
Braz J Cardiovasc Surg ; 33(2): 169-175, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29898147

RESUMO

INTRODUCTION: The incidence of postoperative thrombocytopenia after aortic valve replacement (AVR) with the Perceval S Sutureless bioprosthesis remains unclear. The aim of this study was to report thrombocytopenia associated with the use of sutureless AVR. METHODS: The data was collected retrospectively for patients who had isolated AVR with sutureless Perceval S valve (Group A: 72 patients) and was compared with patients who underwent isolated sutured AVR with Perimount Magna Ease Bioprosthesis (Group B: 101 patients) in our institution between June 2014 and January 2017. RESULTS: Cardiopulmonary bypass and cross-clamp time were significantly shorter in group A. Maximum drop in platelet count was 58% mean (day 2.3) in group A versus 44% mean (day 1.7) in group B (P=0.0001). Absolute platelet count on postoperative day 1-6 in group A was significantly less than in group B (P≤0.05). Platelet count recovered to preoperative value in 44% patients in group B versus only in 26% patients in group A at discharge (P=0.018). Moderate thrombocytopenia occurs more often in group A (41% vs. 26%) (P=0.008) while severe thrombocytopenia (<50 x 109) was observed in 6% in group A but never in group B. Platelets (P=0.007) and packed red blood cells (P=0.009) transfusion was significantly higher in the group A. CONCLUSION: The implantation of sutureless Perceval aortic valves was associated with a significant drop in platelet count postoperatively with slow recovery and higher platelets and packed red blood cells transfusion requirements. A prospective randomised trial is needed to confirm our findings.


Assuntos
Bioprótese/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Complicações Pós-Operatórias/etiologia , Trombocitopenia/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Ponte Cardiopulmonar/efeitos adversos , Constrição , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Contagem de Plaquetas , Desenho de Prótese , Estudos Retrospectivos , Procedimentos Cirúrgicos sem Sutura/efeitos adversos , Procedimentos Cirúrgicos sem Sutura/métodos , Fatores de Tempo , Resultado do Tratamento
3.
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;33(2): 169-175, Mar.-Apr. 2018. tab
Artigo em Inglês | LILACS | ID: biblio-958397

RESUMO

Abstract Introduction: The incidence of postoperative thrombocytopenia after aortic valve replacement (AVR) with the Perceval S Sutureless bioprosthesis remains unclear. The aim of this study was to report thrombocytopenia associated with the use of sutureless AVR. Methods: The data was collected retrospectively for patients who had isolated AVR with sutureless Perceval S valve (Group A: 72 patients) and was compared with patients who underwent isolated sutured AVR with Perimount Magna Ease Bioprosthesis (Group B: 101 patients) in our institution between June 2014 and January 2017. Results: Cardiopulmonary bypass and cross-clamp time were significantly shorter in group A. Maximum drop in platelet count was 58% mean (day 2.3) in group A versus 44% mean (day 1.7) in group B (P=0.0001). Absolute platelet count on postoperative day 1-6 in group A was significantly less than in group B (P≤0.05). Platelet count recovered to preoperative value in 44% patients in group B versus only in 26% patients in group A at discharge (P=0.018). Moderate thrombocytopenia occurs more often in group A (41% vs. 26%) (P=0.008) while severe thrombocytopenia (<50 x 109) was observed in 6% in group A but never in group B. Platelets (P=0.007) and packed red blood cells (P=0.009) transfusion was significantly higher in the group A. Conclusion: The implantation of sutureless Perceval aortic valves was associated with a significant drop in platelet count postoperatively with slow recovery and higher platelets and packed red blood cells transfusion requirements. A prospective randomised trial is needed to confirm our findings.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/etiologia , Trombocitopenia/etiologia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Aórtica/cirurgia , Contagem de Plaquetas , Desenho de Prótese , Fatores de Tempo , Ponte Cardiopulmonar/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Constrição , Implante de Prótese de Valva Cardíaca/métodos , Procedimentos Cirúrgicos sem Sutura/efeitos adversos , Procedimentos Cirúrgicos sem Sutura/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA