Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
Jt Dis Relat Surg ; 35(2): 267-275, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38727104

RESUMO

OBJECTIVES: This study aims to assess the association between isolated subscapularis tears and coracoid morphology using magnetic resonance imaging (MRI) and to calculate the optimal cut-off values of the significant predictor to predict subscapularis tears. PATIENTS AND METHODS: Between January 2018 and December 2022, a total of 60 patients (29 males, 31 females; mean age: 58.4±8.4 years; range, 18 to 80 years) diagnosed with subscapularis tendon tears who were treated as Group A and 60 patients (29 males, 31 females; mean age: 46.8±11.5 years; range, 18 to 80 years) without subscapularis tendon tears who were treated as Group B were included. Axial coracoid-humeral distance (aCHD), sagittal coracoid-humeral distance (sCHD), coracoid overlap (CO) and coracoid angle (CA) of all patients were measured. Logistic regression was used to investigate the association between subscapularis tears as variables including aCHD, sCHD, CO and CA. Receiver operating characteristic curve analysis was used to determine the diagnostic values of coracoid morphology for subscapularis tears. RESULTS: The mean values of CO, aCHD and sCHD in Group A were 22.16 mm, 5.13 mm, and 5.56 mm, respectively. The mean values in Group B were 16.99 mm, 7.18 mm, and 7.29 mm, respectively. The degree of CA in Group A was 95.81 and 111.69 in Group B. The differences in the above measurement values were significant between two Groups. The CO was found to be associated with higher odds of subscapularis tears. The optimal cut-off value of CO was 19.79 mm. CONCLUSION: Based on our study results, CO is positively associated with isolated subscapularis tears. In addition, coracoid bursa effusion, cysts in the lesser tuberosity or a tear and malposition of long head of the biceps tendon on MRI may predict the presence of a clinically significant subscapularis tear.


Assuntos
Processo Coracoide , Imageamento por Ressonância Magnética , Lesões do Manguito Rotador , Humanos , Masculino , Feminino , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Adulto , Idoso , Adolescente , Processo Coracoide/diagnóstico por imagem , Adulto Jovem , Idoso de 80 Anos ou mais , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/patologia , China , Estudos Retrospectivos , População do Leste Asiático
2.
Am J Case Rep ; 25: e943108, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38544309

RESUMO

BACKGROUND Coracoid process fractures are uncommon and are often complicated by many types of shoulder girdle injuries. Previous reports have shown that osteosynthesis for isolated coracoid process fractures results in favorable outcomes and high bone union rates. However, owing to the rarity of coracoid process fractures combined with distal clavicle fractures, there are limited data to guide treatment strategies. We report a case of symptomatic nonunion despite performing osteosynthesis for fractures of the coracoid process and distal clavicle. CASE REPORT A 60-year-old man presented with left shoulder pain after falling from the back of a truck. Radiography and computed tomography (CT) findings revealed fractures of the left distal clavicle and coracoid process. We performed plate and costoclavicular fixation using a suture button for the distal clavicle fracture and cannulated cancellous screw fixation for the coracoid process fracture. However, the patient experienced severe pain around the coracoid and had limited shoulder range of motion 1 year postoperatively. CT revealed nonunion of the coracoid process, prompting a recommendation for surgery. However, despite severe persistent functional impairment, the patient refused surgery 1.5 years postoperatively. CONCLUSIONS This case suggests the potential for symptomatic nonunion of the coracoid process when using a suture-button device for a distal clavicle fracture. To prevent postoperative nonunion of the coracoid process, postoperative CT evaluation is necessary. If a symptomatic delayed bone union of coracoid process is observed, considering early removal of the suture button is recommended.


Assuntos
Clavícula , Fraturas Ósseas , Masculino , Humanos , Pessoa de Meia-Idade , Clavícula/diagnóstico por imagem , Clavícula/cirurgia , Clavícula/lesões , Processo Coracoide/diagnóstico por imagem , Processo Coracoide/cirurgia , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Fixação Interna de Fraturas/métodos , Suturas , Resultado do Tratamento
3.
Chin J Traumatol ; 27(2): 121-124, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37210253

RESUMO

A fracture of the acromion and coracoid processes of scapula is rarely seen in the outpatient clinic, due to the acromion's anatomical position and shape, as well as the strong ligaments and muscles that are attached to it. These fractures are caused by either direct or indirect high-energy trauma injuries to the shoulder joint, leading to severe pain and a grossly restricted range of motion. Several acromial classifications were reported, but this type of longitudinal plane fracture of the acromion process in our case is yet to be described in the current literature. We present a rare combination of the coracoid process and unstable acromion bony projection fractures that have not previously been noted for this type of fracture. The closest to this is Kuhn's type III classification. A 51-year-old male presented to our emergency department complaining of the right shoulder pain and difficulty raising his arm following a 2-wheeler accident. The patient was managed by open reduction and internal fixation with 3 cannulated cancellous screws fixation and progressed well with no postoperative complications. He was asymptomatic postoperatively and regained full range of motion after 4 months.


Assuntos
Acrômio , Fraturas Ósseas , Masculino , Humanos , Pessoa de Meia-Idade , Acrômio/diagnóstico por imagem , Acrômio/cirurgia , Acrômio/lesões , Processo Coracoide/diagnóstico por imagem , Processo Coracoide/cirurgia , Escápula/lesões , Escápula/cirurgia , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Fixação Interna de Fraturas
4.
Orthop Surg ; 14(10): 2692-2700, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36093615

RESUMO

OBJECTIVE: An agreement has not been reached on optimal locations of bone tunnels for coracoclavicular ligament (CCL) reconstruction for acromioclavicular joint dislocation (ACD). This study aims to identify the convergence point (cP) between the coracoid process and clavicle in the Chinese population to assist surgeons in reconstructing the CCL for ACD. METHODS: From 2014 to 2020, 483 CT scans of the shoulders of 270 male and 213 female patients (247 right and 236 left shoulders) were collected and studied retrospectively. By overlapping the images of the transverse plane of the coracoid process and the clavicle, points a and b, and the midpoint ab (cP) were determined. Then, a series of parameters through point cP in the transverse and sagittal planes were measured. In the transverse plane this included the distance from point cP to the tip of the coracoid process (cP-cor),the distance between the medial and lateral margins of the coracoid process through point cP (Med-lat cor), the distance from point cP to the acromioclavicular joint (cP-ac), and the distance between the anteroposterior margin of the clavicle through point cP (Ap-clav). In the sagittal plane, this included the craniocaudal segment of the coracoid process (Cc-cor), and the craniocaudal segment of the clavicle (Cc-clav). The sex and side differences of these measurements were also analyzed by two radiologists. RESULTS: Based on the following measurements, point cP was determined. For male patients, the cP-cor was 28.02 ± 3.43 mm, Med-lat cor was 22.78 ± 2.80 mm, Cc-cor was 15.11 ± 2.13 mm, cP-ac was 29.24 ± 3.84 mm, Ap-clav was 18.27 ± 2.46 mm, and Cc-clav was 10.09 ± 1.56 mm. For female patients, the cP-cor was 25.20 ± 3.26 mm, Med-lat cor was 20.21 ± 2.97 mm, Cc-cor was 13.03 ± 1.77 mm, cP-ac was 26.66 ± 3.45 mm, Ap-clav was 16.10 ± 2.30 mm, and Cc-clav was 8.91 ± 1.40 mm. All the measurements of female patients were lower than those of male patients (p < 0.01). Between sides, only cP-ac of the left shoulders was significantly lower than those of the right shoulders (p < 0.05), with no significant differences in other parameters between sides (p > 0.05). CONCLUSION: The results of this study identified the locations of bone tunnel-cP in the coracoid process and clavicle for the CCL reconstruction in ACD. Moreover, the findings indicated that surgeons should be more cautious in operating on female patients and that the cP-ac of left shoulders should be set lower than that of right shoulders.


Assuntos
Articulação Acromioclavicular , Luxação do Ombro , Articulação Acromioclavicular/diagnóstico por imagem , Articulação Acromioclavicular/cirurgia , Clavícula/diagnóstico por imagem , Clavícula/cirurgia , Processo Coracoide/diagnóstico por imagem , Processo Coracoide/cirurgia , Feminino , Humanos , Ligamentos Articulares/diagnóstico por imagem , Ligamentos Articulares/cirurgia , Masculino , Estudos Retrospectivos , Luxação do Ombro/cirurgia , Tomografia Computadorizada por Raios X
5.
J Orthop Surg Res ; 17(1): 371, 2022 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-35907891

RESUMO

BACKGROUND: We created patient-based 3D finite-element (FE) models that simulate the congruent-arc Latarjet (CAL) and traditional Latarjet (TL) procedures and then compared their stress distribution patterns with different arm positions and glenoid defects. METHODS: The computed tomography data of 10 adult patients (9 men and 1 woman, ages: 18-50 years) were used to develop the 3D FE glenohumeral joint models. Twenty-five and 35% bony defects were created on the anterior glenoid rim, and the coracoid process was transferred flush with the glenoid by the traditional and congruent-arc techniques using two half-threaded screws. A load was applied to the greater tuberosity toward the center of the glenoid, and a tensile force (20 N) was applied to the coracoid tip along the direction of the conjoint tendon. The distribution patterns of the von Mises stress in the traditional and congruent-arc Latarjet techniques were compared. RESULTS: The mean von Mises on the graft was significantly greater for the TL technique than for the CAL. While the von Mises stress was greater in the distal medial part of the graft in the TL models, a higher stress concentration was observed in the distal lateral edge of the coracoid graft in the CAL models. The proximal medial part of the graft exhibited significantly lower von Mises stress than the distal medial part when compared according to technique, defect size, and arm position. Increasing the glenoid defect from 25 to 35% resulted in a significant increase in stress on the lateral side of the graft in both models. CONCLUSION: The stress distribution patterns and stress magnitude of the coracoid grafts differed according to the procedure. Due to placing less stress on the proximal-medial part of the graft, the CAL technique may lead to insufficient stimulation for bone formation at the graft-glenoid interface, resulting in a higher incidence of graft osteolysis. Clinical relevance The CAL technique may lead to a higher incidence of graft osteolysis. LEVEL OF EVIDENCE: Basic Science Study; Computer Modeling.


Assuntos
Instabilidade Articular , Osteólise , Articulação do Ombro , Adolescente , Adulto , Transplante Ósseo/métodos , Processo Coracoide/diagnóstico por imagem , Processo Coracoide/cirurgia , Feminino , Humanos , Instabilidade Articular/cirurgia , Masculino , Pessoa de Meia-Idade , Escápula/diagnóstico por imagem , Escápula/cirurgia , Articulação do Ombro/cirurgia , Adulto Jovem
6.
J Shoulder Elbow Surg ; 31(7): 1442-1450, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35101607

RESUMO

BACKGROUND: Articular-side tear at the upper border of the subscapularis (SSC-AST) is often detected during shoulder arthroscopic surgery, although its exact pathology remains unknown. The purpose of this study was to investigate the correlation between various characteristics of the coracoid process, including classification of the morphology of the coracoid process tip, and the presence of SSC-AST. METHODS: This retrospective, case-controlled study included patients who underwent arthroscopic subacromial decompression with or without rotator cuff repair between January 2018 and September 2021. A total of 130 shoulders in 124 patients, including 77 male and 53 female shoulders (mean age at surgery, 64 years [range, 39-88 years]), were included in this study. Three-dimensional (3D) computed tomography examination was performed preoperatively, and the following indices were measured: coracoid proximal length, coracoid distal length, coracoid angle, coracoglenoid angle, offset of the coracoid process and glenoid (anterior, lateral, and superior offset), and coracoid base angle. The morphology of the tip of the coracoid process was classified into 3 types according to 3D reconstructed views: flat type, round type, and beak type. The presence of SSC-AST was intraoperatively evaluated arthroscopically via a posterior glenohumeral portal. Morphologic risk factors for SSC-AST were evaluated between SSC-AST cases (group T) and non-SSC-AST cases (group N) by multivariable logistic analysis. In addition, the correlation between the incidence of SSC-AST and classification of the tip of the coracoid process was analyzed. RESULTS: SSC-AST was present in 53 shoulders (40.8%). Group T patients were significantly older than group N patients (68.4 ± 10.0 years vs. 61.5 ± 11.8 years, P < .001). No sex difference was detected between the 2 groups (28 male and 25 female shoulders in group T vs. 49 male and 28 female shoulders in group N, P = .28). Multivariate analysis of morphologic parameters between the 2 groups detected a smaller superior offset as a risk factor for SSC-AST (odds ratio, 0.91; 95% confidence interval, 0.84-0.98; P = .01). No significant differences were found in the other parameters. Regarding classification of the tip of the coracoid process, round- and beak-type coracoid tips had a significantly higher rate of SSC-AST than flat-type tips (flat type, 21.8%; round type, 64.7%; and beak type, 46.3%) (P < .001). CONCLUSIONS: Evaluation of the correlation between the morphology of the coracoid process on 3D computed tomography and the presence of SSC-AST visualized during arthroscopy indicated a significant association between SSC-AST and the morphology of the coracoid process.


Assuntos
Lacerações , Lesões do Manguito Rotador , Articulação do Ombro , Artroscopia/métodos , Processo Coracoide/diagnóstico por imagem , Feminino , Humanos , Masculino , Estudos Retrospectivos , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Ruptura , Escápula/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia
7.
J Orthop Surg (Hong Kong) ; 30(1): 23094990211069694, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35041540

RESUMO

INTRODUCTION: The coracoid process is an important anatomical structure of the scapula, which can be used as a landmark in the diagnosis and treatment of scapula related diseases, such as acromioclavicular joint dislocation, anterior shoulder instability, and coracoid fractures. The aim of this study was to classify the coracoid process according to morphology and to measure the morphological parameters of the coracoid process. MATERIALS AND METHODS: A total of 377 dry and intact scapulae were collected and classified in terms of the connection between the shape of coracoid process and common things in life. The anatomical morphology and the position related to acromion and glenoid socket of the coracoid process were measured in each type by three independent researchers with a digital caliper. The measurements were averaged and recorded. RESULTS: Based on obvious morphological features, five specific types of the coracoid process were described: Type I, Vertical 8-shape; Type II, Long stick shape; Type III, Short stick shape; Type IV, Water drop shape, and Type V, Wedge shape. Type I (30%) and Type III (29%) were more prevalent in China. The tip width of the coracoid process of Type IV was the shortest and significantly different compared to the other types (p <.05), contrary to the longest in Type V. The tip thickness of the coracoid process of Type I was the shortest and significantly different from the other types (p <.05). CONCLUSIONS: The coracoid process was classified into five types based on obvious morphological features. Knowing of morphological classification and anatomical parameters of different types of the coracoid process, to some extent, may be helpful to diagnose and treat the shoulder joint disease, such as acromioclavicular joint dislocation, anterior shoulder instability, and coracoid fractures, and to theoretically reduce postoperative complications.


Assuntos
Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Processo Coracoide/diagnóstico por imagem , Humanos , Instabilidade Articular/cirurgia , Escápula/diagnóstico por imagem , Escápula/cirurgia , Luxação do Ombro/diagnóstico por imagem , Luxação do Ombro/cirurgia , Articulação do Ombro/cirurgia
8.
Pan Afr Med J ; 38: 215, 2021.
Artigo em Francês | MEDLINE | ID: mdl-34046121

RESUMO

Anterior shoulder instability following traumatic dislocation in young adults is a common complication. The Latarjet procedure is the most widely used technique for treating this instability. It is based on coracoid abutment repair of the anterior edge of the glenoid. However, joint exposure during this surgical technique is often limited and makes it difficult to position the abutment. The purpose of this study was to evaluate the result of coracoid abutment procedure on functional outcome in the short and medium term. We assessed the positioning of the coracoid abutment on standard postoperative X-rays and the functional outcome according to Duplay score as well as the satisfaction rate in 70 patients. The average age of patients was 25 and a half years, the sex-ratio was nine, and the mean follow-up period was 6.5 years. Radiological examination showed that coracoid abutment was in subequatorial or non-flush position with respect to the anterior glenoid rim (too internal or protruding in intra-articular position) in 20% of cases. This group showed a drop in mean stability score by 7.68 points, in pain by 10.04 points and in Duplay's overall score by 13.3 points as well as a significant increase in the level of glenohumeral arthrosis. This study highlights that coracoid abutment in subequatorial or non-flush position has deleterious effect on the functional outcome of the Latarjet procedure.


Assuntos
Instabilidade Articular/cirurgia , Luxação do Ombro/cirurgia , Articulação do Ombro/cirurgia , Adolescente , Adulto , Processo Coracoide/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Instabilidade Articular/diagnóstico por imagem , Masculino , Satisfação do Paciente , Radiografia , Estudos Retrospectivos , Luxação do Ombro/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem , Resultado do Tratamento , Adulto Jovem
9.
J Orthop Surg Res ; 16(1): 58, 2021 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-33446228

RESUMO

BACKGROUND: Fractures of the base of the coracoid process are relatively rare, but an increasing number of studies have reported using screws to fix coracoid process base fractures. This study was performed to simulate the surgical procedure and obtain the ideal diameter, length, insertion point and angle of the screw from a 3-D axial perspective in Chinese patients. METHODS: We randomly collected right scapula computed tomography (CT) scans from 100 adults. DICOM-formatted CT scan images were imported into Mimics software. A 3D digital model of the right scapula was established. Two virtual cylinders representing two screws were placed from the top of the coracoid process to the neck of the scapula and across the base of the coracoid process to fix the base of the coracoid process. The largest secure diameters and lengths of the virtual screws were measured. The positions of the insertion points and the directions of the screws were also examined. RESULTS: The screw insertion safe zone can exhibit an irregular fusiform shape according to the reconstructed scapula model. The mean maximum diameters of the medial and lateral screws were 7.08 ± 1.19 mm and 7.34 ± 1.11 mm, respectively. The mean maximum lengths of the medial and lateral screws were 43.11 ± 6.31 mm and 48.16 ± 6.94 mm, respectively. A screw insertion corridor with a diameter of at least 4.5 mm was found in all patients. We found sex-dependent differences in the mean maximum diameters and maximum lengths of the two screws. The positions of the two insertion points were statistically different across sexes. CONCLUSIONS: The study provides a valuable guideline for determining the largest secure corridor for two screws in fixing a fracture at the base of the coracoid process. For ideal screw placement, we suggest individualised preoperative 3D reconstruction simulations. Further biomechanical studies are needed to verify the function of the screws.


Assuntos
Parafusos Ósseos , Processo Coracoide/lesões , Processo Coracoide/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Povo Asiático , Processo Coracoide/diagnóstico por imagem , Feminino , Fraturas Ósseas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Escápula/diagnóstico por imagem , Caracteres Sexuais , Adulto Jovem
10.
Knee Surg Sports Traumatol Arthrosc ; 29(7): 2103-2109, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32691091

RESUMO

PURPOSE: The optimal (SBJI) surgical treatment for acute acromioclavicular (AC) joint disruption remains controversial. What is being presented is the long-term functional outcomes of a double cross-looped coracoclavicular (CC) suture technique with the intention of restoring both anteroposterior and superior displacement of the clavicle. METHODS: Between 2007 and 2016, 81 patients underwent surgical reconstruction for acute acromioclavicular joint (AC) disruption in two orthopaedic centers. Two patients died for reasons unrelated to the treatment, and seven missed the final follow-up appointment, leaving 72 patients (67 males; 5 females; age 37 ± 12.4; range 15-64 years) for clinical and radiological assessments. All cases were classified according to the Rockwood classification as type III (n = 34), IV (n = 14) or V (n = 24). The dislocation was repaired with double cross-looped CC fixation using four Ethibond sutures passing underneath the coracoid and through a 4.5 mm drill hole in the clavicle in opposing directions to control both anteroposterior and vertical displacement. Radiological investigation preoperatively and at the last follow-up included anteroposterior and/or Zanca views, axillary or Alexander views, and comparative stress radiography of both AC joints. Patients were evaluated clinically with the Constant-Murley score (CMS) and Acromio Clavicular Joint Instability Score (ACJIS). Loss of reduction, subluxation, CC ligament ossification, post-traumatic arthritis, and peri-implant fractures were also recorded. RESULTS: Seventy-two patients were available for the last clinical and radiological evaluations. At a median follow-up period of 6.3 ± 2.1 years (range 3-12 years), the CMS and ACJIS were 92.1 ± 7.2 (range 60-100 points) and 90.4 ± 8.6 (range 45-100 points), respectively. Complications included 9 (12.5%) patients with slight loss of reduction, 2 (1.7%) with dislocation recurrence, 1 (1.3%) with superficial infection, 1 (1.3%) with a fracture of the lateral end of the clavicle, and 2 (1.7%) with persistent tenderness in the AC joint. The incidence of periarticular ossification was 22.4% and did not affect the final outcome. CONCLUSIONS: This technique represents an effective and low-cost treatment for acute AC joint separations. LEVEL OF EVIDENCE: IV.


Assuntos
Clavícula/lesões , Clavícula/cirurgia , Processo Coracoide/lesões , Processo Coracoide/cirurgia , Luxações Articulares/cirurgia , Procedimentos Ortopédicos/métodos , Técnicas de Sutura , Adolescente , Adulto , Traumatismos em Atletas/diagnóstico por imagem , Traumatismos em Atletas/cirurgia , Clavícula/diagnóstico por imagem , Processo Coracoide/diagnóstico por imagem , Feminino , Humanos , Luxações Articulares/diagnóstico por imagem , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , Ligamentos Articulares/cirurgia , Masculino , Pessoa de Meia-Idade , Procedimentos Ortopédicos/efeitos adversos , Complicações Pós-Operatórias , Radiografia , Resultado do Tratamento , Adulto Jovem
11.
J Bone Joint Surg Am ; 103(1): 15-22, 2021 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-33165127

RESUMO

BACKGROUND: The prevalence of nonunion after the Latarjet procedure remains high. The purpose of the present study was to investigate healing and clinical outcomes after a novel arthroscopic coracoid process transfer procedure. METHODS: Sixty-three patients who underwent the arthroscopic inlay Bristow procedure combined with Bankart repair were identified, and 51 patients who met the inclusion criteria were enrolled in this study. The key feature of this technique was that the coracoid process was trimmed and fixed into a trough (5 to 10 mm deep) in the glenoid neck with a metal screw. Bone graft union and positioning accuracy were assessed with use of postoperative computed tomography (CT) imaging. Clinical examinations, return to sport, and functional scores (American Shoulder and Elbow Surgeons [ASES] and Rowe scores) were recorded. RESULTS: The mean duration of follow-up (and standard deviation) was 41.5 ± 7.7 months (range, 36 to 48 months). Postoperative CT scans showed that the position of coracoid graft was at 4:10 (from 3:50 to 5:00) (referencing the right shoulder) in the sagittal view. The α angle was 16.4° ± 9.5°, with 4 (7.8%) of 51 screws being over-angulated (α > 25°). On the axial view, the graft position was considered to be flush in 33 patients (64.7%), medial in 11 (21.6%), congruent in 7 (13.7%), and lateral or too medial in none. At 1 year, the coracoid graft had healed in 49 patients (96.1%) and had failed to unite in 2 patients. CT scanning, performed for 47 patients, showed grade-0 osteolysis in 9 patients, grade-1 osteolysis in 21 patients, and grade-2 osteolysis in 17 patients. At the time of the latest follow-up, there was a significant increase in the Rowe score (from 35.5 ± 8.3 to 95.7 ± 7.2) and the ASES score (from 71.2 ± 9.7 to 91.5 ± 4.4), and 87.0% of patients were able to return to sport. No arthropathy was observed in any patient. CONCLUSIONS: After a minimum 3-year follow-up, the arthroscopic inlay Bristow procedure resulted in a high rate of graft healing, excellent clinical outcomes, and a high rate of return to sports. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia/métodos , Luxação do Ombro/cirurgia , Fraturas do Ombro/cirurgia , Articulação do Ombro/cirurgia , Adolescente , Adulto , Artroplastia/reabilitação , Artroscopia , Transplante Ósseo/métodos , Processo Coracoide/diagnóstico por imagem , Processo Coracoide/cirurgia , Processo Coracoide/transplante , Seguimentos , Humanos , Imageamento Tridimensional , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , Pessoa de Meia-Idade , Estudos Prospectivos , Recuperação de Função Fisiológica , Recidiva , Volta ao Esporte , Luxação do Ombro/diagnóstico por imagem , Luxação do Ombro/reabilitação , Fraturas do Ombro/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Cicatrização , Adulto Jovem
12.
Surg Radiol Anat ; 43(5): 631-643, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33165647

RESUMO

INTRODUCTION: The proximal insertion beyond coracoid process of pectoralis minor is considered as hidden culprit of rotator cuff disorders. The ectopic insertion is also associated with thoracic outlet syndrome. The current review was conducted to provide a comprehensive evidence-based assessment of the anatomical characteristics of ectopic insertion of pectoralis minor. MATERIALS AND METHODS: A through systematic search was conducted on the major electronic database, PubMed, EMBASE, Google Scholar and Journals of Anatomy, orthopedics, plastic surgery, sports medicine. The primary outcome was to measure the prevalence of ectopic insertion of pectoralis minor tendons. The data extraction was conducted for pooled estimation and metanalysis. RESULTS: A total of 25 studies were included for systematic review. The overall pooled estimate of ectopic insertion of Pectoralis Minor was 19.27% (95% CI 15-24%). The prevalence rate in dissected specimen was 21% (CI 15-28%) and in arthroscopic evaluation was 22% (95% CI 5-59%) which was marginally higher with wide confidence interval due small sample size. The prevalence rate in MRI and USG were 15 and 12%, because MRI and USG have almost similar sensitivity in the detection of anomalous insertion of Pectoralis Minor. The distribution of subtypes of anomalous or ectopic insertion based on Le Double classification was 34% for type I, 42 and 9% for Type III. The incidence of ectopic insertion of pectoralis minor was highest in Japanese population. The female and left side have slightly higher incidence at insignificant level. CONCLUSION: The preoperative MRI or at least USG evaluation of shoulder joint must be conducted for appropriate surgical planning, because the prevalence of ectopic insertion is around 20%. The preoperative detection of anomalous insertion of pectoralis minor can be crucial in minimizing the incidences of iatrogenic injuries of tendon or post-operative complications.


Assuntos
Processo Coracoide/anormalidades , Músculos Peitorais/anormalidades , Lesões do Manguito Rotador/etiologia , Tendões/anormalidades , Processo Coracoide/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Músculos Peitorais/diagnóstico por imagem , Prevalência , Tendões/diagnóstico por imagem , Ultrassonografia
13.
J Shoulder Elbow Surg ; 30(7): 1503-1510, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33157238

RESUMO

BACKGROUND: The success of the modified Latarjet procedure depends on proper sizing of the coracoid graft. There is no information available regarding the morphometric relationship between the glenoid cavity and the coracoid process for the South African population. This study aims at measuring the relationship between the glenoid and coracoid morphometries and investigates their gender-related differences. METHODS: Glenohumeral computerized tomography scans of 100 consecutive patients were considered for this study. Morphometric measurements were performed after aligning the coracoid and glenoid in their optimum orientation. These measurements were performed by 2 independent observers. The ratio between glenoid and coracoid measurements was calculated and statistically compared using the Mann-Whitney U test. Intraclass correlation coefficients were calculated to analyze interobserver reliability. All the statistical tests were performed in SPSS v.26, and power calculations in G∗Power v.3.1. RESULTS: An average intraclass correlation coefficient value of 0.79 suggested that the interobserver reliability was good. Except for coracoid length, statistically significant (P < .05) gender differences were observed for all the other morphometries. The coracoid width (16.5 ± 1.4 mm vs. 14.7 ± 1.4 mm) and height (13.6 ± 1.6 mm vs. 10.5 ± 1.5 mm) differed between genders by 1.8 and 3.1 mm, respectively. The glenoid anteroposterior (AP) (25.3 ± 2.9 mm vs. 23.2 ± 2.4 mm) and superioinferior (36.9 ± 1.9 mm vs. 33.7 ± 2.6 mm) measurements differed by 2.1 and 3.3 mm, respectively, between the males and the females. The ratio between the AP width of the glenoid and the coracoid height was also found to be significantly different (P < .05) between the gender groups. These morphometric ratios for the coracoid width (0.66 ± 0.09 mm vs. 0.64 ± 0.08 mm) and the coracoid height (0.55 ± 0.09 mm vs. 0.46 ± 0.07 mm) differed between genders by 0.02 and 0.09, respectively. CONCLUSION: Measurements taken from computerized tomography scans showed significant differences between genders in absolute measurements and in the ratio of the coracoid height to the glenoid AP distance. This could have implications on the ability of the Latarjet procedure to compensate for bone loss in female patients.


Assuntos
Instabilidade Articular , Articulação do Ombro , Transplante Ósseo , Processo Coracoide/diagnóstico por imagem , Processo Coracoide/cirurgia , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Escápula/diagnóstico por imagem , Escápula/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Tomografia Computadorizada por Raios X
15.
J Orthop Surg (Hong Kong) ; 28(3): 2309499020964602, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33150837

RESUMO

PURPOSE: In this study, we aimed to reveal the individual differences regarding the size of the coracoid and their effects on the classical and modified Latarjet procedures. METHODS: Computed tomography images of 120 patients (mean age: 41.18 ± 12.01 years) without shoulder complaints or shoulder instability were evaluated retrospectively. The glenoid width, the surgical graft length, and the coracoid total length, width, and thickness were measured using the multiplanar reconstruction method on the Sectra Picture Archiving and Communications System (PACS) system. Age, gender, side, the dominant hand, and the height of the patients were recorded and the correlations between them were investigated. On the created hypothetical model, the current size of the coracoid was evaluated to determine what size of glenoid defects it could repair by employing the classical and the modified Latarjet techniques. RESULTS: There was no significant difference between the right-hand-dominant group and the left-hand-dominant group in terms of coracoid measurement results (p > 0.05). Again, there was no statistically significant difference between the right and the left side regarding the coracoid size (p > 0.05). A positive correlation could be detected only between age and the coracoid width and thickness (p < 0.05). A positive correlation was also found between the glenoid width and the coracoid width and thickness in both shoulders (p < 0.001). Coracoid thickness could fill in the defects that amounted to 40% of the glenoid width, while the coracoid width could fill in for the defects that were 50% of the glenoid width in both genders. CONCLUSION: Our study showed that hand dominance and side were not effective on the coracoid dimensions. In addition, it has been shown that the coracoid dimensions did not have a significant effect in the choice of Latarjet technique in terms of defect repair and that repair rates of up to 40% could be achieved in glenoid defects with both techniques.


Assuntos
Processo Coracoide/anatomia & histologia , Processo Coracoide/diagnóstico por imagem , Articulação do Ombro/anatomia & histologia , Articulação do Ombro/diagnóstico por imagem , Adulto , Artroplastia , Transplante Ósseo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Adulto Jovem
16.
J Am Acad Orthop Surg ; 28(16): e706-e715, 2020 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-32769719

RESUMO

Fractures of the coracoid process are relatively rare, and current management guidelines remain unclear. Most coracoid fractures occur in conjunction with other shoulder injuries, including dislocations and fractures. Identifying coracoid fractures can be difficult because most fractures are nondisplaced and can be missed on radiographs or may be masked by other injuries. Management is largely guided by fracture location and displacement. Conservative treatment is preferred for fractures that are minimally displaced, whereas indications for surgical fixation include fractures that are displaced (>1 cm), have progressed to a painful nonunion, or are associated with the disruption of the superior shoulder suspensory complex. Although conservative treatment has been historically favored, satisfactory outcomes have been reported for both surgical and nonsurgical treatment. We provide a comprehensive review of diagnosis and management strategies for coracoid fractures.


Assuntos
Tratamento Conservador/métodos , Processo Coracoide/lesões , Fraturas Ósseas/terapia , Processo Coracoide/anatomia & histologia , Processo Coracoide/diagnóstico por imagem , Fraturas Ósseas/diagnóstico , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Humanos , Imageamento Tridimensional , Procedimentos Ortopédicos/métodos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
17.
J Shoulder Elbow Surg ; 29(12): 2632-2639, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32713665

RESUMO

BACKGROUND: Although the osteolysis of the coracoid graft is frequently observed after the Latarjet procedure particularly in its proximal part, its pathomechanism is not well understood. METHODS: Three-dimensional finite element glenohumeral joint models were developed using CT-DICOM data of 10 normal shoulders. A 25% bony defect was created on the anterior glenoid rim, and the coracoid process was transferred flush with the glenoid cartilage using 2 half-threaded screws. In the hanging arm as well as in the 90° abducted positions, a compressive load (50 N) was applied to the greater tuberosity toward the center of the glenoid and a tensile force (20 N) was applied to the coracoid tip along the direction of the conjoint tendon. Next, elastic analysis was performed, and the distribution patterns of the equivalent stress as well as the maximum principal stress were compared among 4 parts (proximal/distal and medial/lateral) of the coracoid graft. RESULTS: Both the equivalent stress and the maximum principal stress were reduced in the proximal half of the coracoid graft. A high stress concentration was observed in the lateral aspect of the coracoid graft particularly in the 90° abducted position. The proximal-medial part demonstrated the lowest equivalent stress as well as the maximum principal stress for both arm positions, which were significantly lower than those in the distal 2 parts. CONCLUSION: In the Latarjet procedure, the proximal-medial part of the coracoid graft demonstrated the most evident stress shielding, which may play an important role in postoperative osteolysis.


Assuntos
Transplante Ósseo/efeitos adversos , Processo Coracoide/transplante , Instabilidade Articular , Osteólise/fisiopatologia , Luxação do Ombro/cirurgia , Articulação do Ombro , Adolescente , Adulto , Artroscopia , Fenômenos Biomecânicos , Transplante Ósseo/métodos , Simulação por Computador , Processo Coracoide/diagnóstico por imagem , Processo Coracoide/fisiopatologia , Feminino , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/fisiopatologia , Instabilidade Articular/cirurgia , Masculino , Pessoa de Meia-Idade , Osteólise/diagnóstico por imagem , Osteólise/etiologia , Recidiva , Escápula/diagnóstico por imagem , Escápula/cirurgia , Luxação do Ombro/fisiopatologia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiopatologia , Articulação do Ombro/cirurgia , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
18.
Surg Radiol Anat ; 42(8): 877-885, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32418123

RESUMO

PURPOSE: The acromial and coracoid process morphology is of clinical relevance due to associations with functional limitations and shoulder pathology. Our objective was to describe the anatomical characteristics of the acromial and coracoid process using computed tomography (CT). METHODS: Descriptive, observational, transversal and retrospective study. A total of 155 CT of patients without shoulder pathology, of both genders, and indistinct age were evaluated and grouped by age: Group 1 < 25 years; group 2 25-40 years; group 3 > 40 years. The following parameters were evaluated: Acromial type (AcT), vertical coracoid distance (VCD), acromial tilt (AT), acromial projection (AP), critical shoulder angle (CSA), type of the subcoracoid outlet (TSO), and the area of the subcoracoid outlet (ASO). RESULTS: Statistically significant differences were found between men and women for VCD (14.44 ± 4.79 vs. 11.76 ± 4.00 mm; p < 0.001) and AP (3.66 ± 4.71 vs. 1.62 ± 4.99 mm; p < 0.05) as well as between age groups 1 and 3 for AT (35.08 ± 11.53 vs. 28.41 ± 6.60; p < 0.05) and ASO (398.99 ± 153.91 vs. 255.56 ± 124.58 mm2; p < 0.001). An unexpected high ASO variation was identified with 11% of S-shaped acromion and 1.3% clock-shaped TSO. CONCLUSION: The age group between 25-40 years had the most uniform distribution of data. There is a high morphological variability present in an asymptomatic population, which should be considered in the clinical assessment such as shoulder impingement syndrome.


Assuntos
Acrômio/anormalidades , Variação Anatômica , Processo Coracoide/anormalidades , Acrômio/diagnóstico por imagem , Adolescente , Adulto , Fatores Etários , Idoso , Processo Coracoide/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores Sexuais , Síndrome de Colisão do Ombro/diagnóstico , Síndrome de Colisão do Ombro/etiologia , Tomografia Computadorizada por Raios X , Adulto Jovem
19.
Surg Radiol Anat ; 42(8): 895-901, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32405787

RESUMO

PURPOSE: Glenoid bony lesions play a role in approximately half of anterior shoulder instability cases. The purpose of this study is to see if the anatomy of the coracoid affects the location of glenoid rim defects. We hypothesized that a prominent coracoid (lower and lateral) would be more likely to cause an anterior-inferior glenoid lesion, and a less prominent coracoid more prone to cause an anterior lesion. The null hypothesis being the absence of correlation. METHODS: Fifty-one shoulder CT-scans from a prospective database, with 3D reconstruction, were analyzed. The position of glenoid lesions was identified using the validated clock method, identifying the beginning and end time. The size of bony glenoid defects was calculated using the validated glenoid ratio method. The position of the coracoid tip was measured in three orthogonal planes. RESULTS: Analysis included 25 right shoulders and 26 left shoulders in seven females and 41 males. The vertical position of the coracoid tip relative to the top of the glenoid was highly correlated to the location of the glenoid defect on the profile view (r = -0.625; 95% CI 0.423-0.768; p = 0.001). Thus, higher coracoids were associated with anterior lesions, while lower coracoids were associated with anterior-inferior lesions. A more laterally prominent coracoid was also correlated with anterior-inferior lesions (r = 0.433; 95% CI 0.179-0.633; p = 0.002). CONCLUSION: This study shows that coracoid anatomy affects the location of bony Bankart defects in anterior shoulder instability. Lower and laterally prominent coracoids are associated with anterior-inferior lesions. This variation in anatomy should be considered during pre-op planning for surgeries involving bone graft. LEVEL OF EVIDENCE: Level 4 basic science.


Assuntos
Variação Anatômica , Processo Coracoide/anormalidades , Cavidade Glenoide/patologia , Luxação do Ombro/etiologia , Articulação do Ombro/patologia , Adolescente , Adulto , Processo Coracoide/diagnóstico por imagem , Feminino , Cavidade Glenoide/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Ombro , Luxação do Ombro/diagnóstico , Luxação do Ombro/patologia , Articulação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto Jovem
20.
J Shoulder Elbow Surg ; 29(9): 1804-1810, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32307238

RESUMO

BACKGROUND: The pathophysiology of subscapularis (SS) lesions is still relatively unknown despite recent interest in predictive factors for SS tears. Our goal was to determine the influence of the coracoid morphology and humeral version on SS tears. METHODS: This was a retrospective, controlled, single-blinded study. We analyzed 232 shoulders with SS lesions confirmed by magnetic resonance imaging. The coracoid proximal length, coracoid distal length (CLD), and coracoid total length were measured. The coracoid length ratio, coracoid angle (CA), and humeral version were also evaluated. RESULTS: We found that greater humeral retroversion was progressively related to more serious SS injuries, with values of -28.6° ± 19.5° and -51.0° ± 11.1° in the normal SS group and tear group, respectively (P < .001). The same tendency was shown for the CA, with values of 123.8° ± 11.1° in the control group vs. 97.4° ± 10.1° in the tear group (P < .001). Greater CLD, coracoid total length, and coracoid length ratio were also associated with an increased risk of SS tears (P < .001). The CA and CLD represented the best predictors of SS tears, presenting areas under the receiver operating characteristic curve of 90.0% and 89.0%, respectively. CONCLUSIONS: This article is the first to study the influence of different parameters of the coracoid process morphology and humeral version on SS tears. We proved that humeral version and coracoid morphology were important risk factors for SS pathology and could accurately predict these lesions. Finally, our study was the first to create a classification system to divide coracoids according to their morphology and relative risk of associated SS tears.


Assuntos
Processo Coracoide/diagnóstico por imagem , Úmero/diagnóstico por imagem , Lacerações/epidemiologia , Lesões do Manguito Rotador/epidemiologia , Manguito Rotador/diagnóstico por imagem , Lesões do Ombro , Tendinopatia/epidemiologia , Processo Coracoide/patologia , Feminino , Humanos , Úmero/patologia , Imageamento por Ressonância Magnética/métodos , Masculino , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Método Simples-Cego
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...