Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 161
Filtrar
1.
Diagnosis (Berl) ; 11(2): 178-185, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38178595

RESUMO

OBJECTIVES: Outpatient health care facilities are essential for quickly diagnosing common infectious diseases such as bacterial and viral pharyngitis. The only form of pharyngitis requiring antibiotics is strep throat (ST); however, antibiotic prescription rates are much higher than ST prevalence, suggesting antibiotics are being inappropriately prescribed. Current rapid ST diagnostics may be contributing to this problem due to the low sensitivity and variable specificity of these tests. It is best practice to verify a negative ST diagnosis with a group A Streptococcus (GAS) culture, but many clinics do not perform this test due to the additional cost and 24-72 h required to obtain results. This indicates there is great need for more accurate rapid diagnostic tools in outpatient facilities. We hypothesized that next generation qPCR technology could be adapted to detect GAS DNA from saliva samples (instead of the traditional throat swab) by creating a simple, fast, and inexpensive protocol. METHODS: Saliva specimens collected from patients at James Madison University Health Center were used to test the effectiveness of our Chelex 100-based rapid DNA extraction method, followed by a fast protocol developed for the Open qPCR machine to accurately detect ST. RESULTS: Our final saliva processing and qPCR protocol required no specialized training to perform and was able to detect ST with 100 % sensitivity and 100 % specificity (n=102) in 22-26 min, costing only $1.12 per sample. CONCLUSIONS: Saliva can be rapidly analyzed via qPCR for the accurate and inexpensive detection of ST.


Assuntos
Faringite , Reação em Cadeia da Polimerase em Tempo Real , Saliva , Sensibilidade e Especificidade , Infecções Estreptocócicas , Streptococcus pyogenes , Humanos , Saliva/microbiologia , Saliva/química , Infecções Estreptocócicas/diagnóstico , Faringite/diagnóstico , Faringite/microbiologia , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reação em Cadeia da Polimerase em Tempo Real/economia , Streptococcus pyogenes/genética , Streptococcus pyogenes/isolamento & purificação , DNA Bacteriano/análise , DNA Bacteriano/genética , Masculino , Adulto , Feminino
2.
J Biosci ; 462021.
Artigo em Inglês | MEDLINE | ID: mdl-34845993

RESUMO

Real-time PCR is a widely used technique for quantification of gene expression. However, commercially available kits for real-time PCR are very expensive. The ongoing coronavirus pandemic has severely hampered the economy in a number of developing countries, resulting in a reduction in available research funding. The fallout of this will result in limiting educational institutes and small enterprises from using cutting edge biological techniques such as real-time PCR. Here, we report a cost-effective approach for preparing and assembling cDNA synthesis and real-time PCR mastermixes with similar efficiencies as commercially available kits. Our results thus demonstrate an alternative to commercially available kits.


Assuntos
Reação em Cadeia da Polimerase em Tempo Real/métodos , Benzotiazóis , Diaminas , Indicadores e Reagentes , Quinolinas , Reação em Cadeia da Polimerase em Tempo Real/economia
3.
Mol Biol Rep ; 48(11): 7243-7249, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34613565

RESUMO

BACKGROUND: The new SARS-CoV-2 variant VOC (202012/01), identified recently in the United Kingdom (UK), exhibits a higher transmissibility rate compared to other variants, and a reproductive number 0.4 higher. In the UK, scientists were able to identify the increase of this new variant through the rise of false negative results for the spike (S) target using a three-target RT-PCR assay (TaqPath kit). METHODS: To control and study the current coronavirus pandemic, it is important to develop a rapid and low-cost molecular test to identify the aforementioned variant. In this work, we designed primer sets specific to the VOC (202012/01) to be used by SYBR Green-based RT-PCR. These primers were specifically designed to confirm the deletion mutations Δ69/Δ70 in the spike and the Δ106/Δ107/Δ108 in the NSP6 gene. We studied 20 samples from positive patients, detected by using the Applied Biosystems TaqPath RT-PCR COVID-19 kit (Thermo Fisher Scientific, Waltham, USA) that included the ORF1ab, S, and N gene targets. 16 samples displayed an S-negative profile (negative for S target and positive for N and ORF1ab targets) and four samples with S, N and ORF1ab positive profile. RESULTS: Our results emphasized that all S-negative samples harbored the mutations Δ69/Δ70 and Δ106/Δ107/Δ108. This protocol could be used as a second test to confirm the diagnosis in patients who were already positive to COVID-19 but showed false negative results for S-gene. CONCLUSIONS: This technique may allow to identify patients carrying the VOC (202012/01) or a closely related variant, in case of shortage in sequencing.


Assuntos
Benzotiazóis , COVID-19/virologia , Diaminas , Corantes Fluorescentes , Quinolinas , Reação em Cadeia da Polimerase em Tempo Real/métodos , SARS-CoV-2/isolamento & purificação , COVID-19/diagnóstico , Custos e Análise de Custo , Primers do DNA , Genoma Viral , Humanos , Mutação , Reação em Cadeia da Polimerase em Tempo Real/economia , SARS-CoV-2/genética , Sensibilidade e Especificidade , Glicoproteína da Espícula de Coronavírus/genética , Fatores de Tempo
4.
PLoS One ; 16(9): e0257454, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34555079

RESUMO

The following protocol describes our workflow for processing wastewater with the goal of detecting the genetic signal of SARS-CoV-2. The steps include pasteurization, virus concentration, RNA extraction, and quantification by RT-qPCR. We include auxiliary steps that provide new users with tools and strategies that will help troubleshoot key steps in the process. This protocol is one of the safest, cheapest, and most reproducible approaches for the detection of SARS-CoV-2 RNA in wastewater. Owing to a pasteurization step, it is safe for use in a BSL2 facility. In addition to making the protocol safe for the personnel involved, pasteurization had the added benefit of increasing the SARS-CoV-2 genetic signal. Furthermore, the RNA obtained using this protocol can be sequenced using both Sanger and Illumina sequencing technologies. The protocol was adopted by the New York City Department of Environmental Protection in August 2020 to monitor SARS-CoV-2 prevalence in wastewater in all five boroughs of the city. In the future, this protocol could be used to detect a variety of other clinically relevant viruses in wastewater and serve as a foundation of a wastewater surveillance strategy for monitoring community spread of known and emerging viral pathogens.


Assuntos
RNA Viral/genética , SARS-CoV-2/genética , Águas Residuárias/virologia , COVID-19/virologia , Custos e Análise de Custo/economia , Humanos , Cidade de Nova Iorque , Prevalência , Reação em Cadeia da Polimerase em Tempo Real/economia , Reação em Cadeia da Polimerase em Tempo Real/métodos
5.
Biomed Res Int ; 2021: 6653950, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34124257

RESUMO

The study is aimed at establishing the optimal parameters for RNA purification of pooled specimens, in SARS-CoV-2 assay. This research work evaluates the difference of extracted RNA purity of pooled samples with and without treatment with isopropyl alcohol and its effect on real-time RT-PCR. As per the protocol of the Indian Council of Medical Research (ICMR), 5 sample pools were analysed using qRT-PCR. A total of 100 pooled samples were selected for the study by mixing 50 µL of one COVID-19 positive nasopharyngeal/oropharyngeal (NP/OP) specimen and 50 µL each of 4 known negative specimens. Pool RNA was extracted using the column-based method, and 1 set of pooled extracted RNA was tested as such, while RNA of the second set was treated additionally with chilled isopropyl alcohol (modified protocol). Further, the purity of extracted RNA in both the groups was checked using Microvolume Spectrophotometers (Nanodrop) followed by RT-PCR targeting E-gene and RNaseP target. The results showed that the purity index of extracted RNA of untreated pooled specimens was inferior to isopropyl alcohol-treated templates, which was observed to be 85% sensitivity and 100% specificity. The average Cq (E gene) in the unpurified and purified pool RNA group was 34.66 and 31.48, respectively. The nanodrop data suggested that purified RNA concentration was significantly increased with an average value of 24.73 ± 1.49 ng/uL, which might be the reason for high sensitivity and specificity. Thus, this group testing of SARS-CoV-2 cases using pools of 5 individual samples would be the best alternative for saving molecular reagents, personnel time, and can increase the overall testing capacity. However, purity of RNA is one of the important determinants to procure unfailing results, thus, this additional purification step must be included in the protocol after RNA has been extracted using commercially available kit before performing qRT-PCR.


Assuntos
COVID-19/diagnóstico , Proteínas do Envelope de Coronavírus/genética , RNA Viral/isolamento & purificação , Reação em Cadeia da Polimerase em Tempo Real/métodos , SARS-CoV-2/genética , 2-Propanol/química , Biomarcadores/análise , COVID-19/virologia , Primers do DNA/síntese química , Primers do DNA/genética , Humanos , Nasofaringe/virologia , Orofaringe/virologia , RNA Viral/genética , Reação em Cadeia da Polimerase em Tempo Real/economia , Reação em Cadeia da Polimerase em Tempo Real/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Anal Bioanal Chem ; 413(11): 2961-2969, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33619642

RESUMO

An accurate genetic diagnostic is key for adequate patient management and the suitability of healthcare systems. The scientific challenge lies in developing methods to discriminate those patients with certain genetic variations present in tumor cells at low concentrations. We report a method called enhanced asymmetric blocked qPCR (EAB-qPCR) that promotes the blocker annealing against the primer-template hybrid controlling thermal cycling and reaction conditions with nonmodified oligonucleotides. Real-time fluorescent amplification curves of wild-type alleles were delayed by about eight cycles for EAB-qPCR, compared to conventional blocked qPCR approaches. This method reduced the amplification of native DNA variants (blocking percentage 99.7%) and enabled the effective enrichment of low-level DNA mutations. Excellent performance was estimated for the detection of mutated alleles in sensitivity (up to 0.5% mutant/total DNA) and reproducibility terms, with a relative standard deviation below 2.8%. The method was successfully applied to the mutational analysis of metastatic colorectal carcinoma from biopsied tissues. The determined single-nucleotide mutations in the KRAS oncogene (codon 12-13) totally agreed with those obtained from next-generation sequencing. EAB-qPCR is an accurate cheap method and can be easily incorporated into daily routine to detect mutant alleles. Hence, these features are especially interesting to facilitate the diagnosis and prognosis of several clinical diseases.


Assuntos
Genes ras , Mutação Puntual , Reação em Cadeia da Polimerase em Tempo Real/métodos , Linhagem Celular , Neoplasias Colorretais/genética , Neoplasias Colorretais/patologia , Humanos , Limite de Detecção , Polimorfismo de Nucleotídeo Único , Reação em Cadeia da Polimerase em Tempo Real/economia , Reprodutibilidade dos Testes
7.
Br J Haematol ; 192(1): 28-32, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32617974

RESUMO

Most cancer cases occur in areas of low resources. The diagnosis, treatment and monitoring of cancers is especially challenging in these locations. Unique partnerships exist between non-profit organisations and pharmaceutical companies to provide free drugs to CML patients throughout the world if the diagnosis can be rigorously and unambiguously established. But there lies the rub: How do you perform molecular diagnostics in areas where even electricity is unreliable? Here we describe the evolution of testing patients from low resource areas, which, when merged with a remarkable effort to bring tyrosine kinase inhibitors to patients across the globe, have led to survival outcomes similar to cases in industrialised countries.


Assuntos
Leucemia Mielogênica Crônica BCR-ABL Positiva/diagnóstico , Antineoplásicos/uso terapêutico , Países em Desenvolvimento , Teste em Amostras de Sangue Seco/economia , Proteínas de Fusão bcr-abl/genética , Humanos , Mesilato de Imatinib/uso terapêutico , Leucemia Mielogênica Crônica BCR-ABL Positiva/sangue , Leucemia Mielogênica Crônica BCR-ABL Positiva/tratamento farmacológico , Leucemia Mielogênica Crônica BCR-ABL Positiva/genética , Técnicas de Diagnóstico Molecular/economia , Reação em Cadeia da Polimerase em Tempo Real/economia , Resultado do Tratamento
8.
PLoS One ; 15(12): e0242408, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33315885

RESUMO

We sought to develop a smooth and low cost sample preparation and DNA extraction protocol, streamlined with a ready-to-use qPCR in a portable instrument to overcome some of the existing hurdles. Several solutions were evaluated as to their ability to liquefy a mucin-based matrix. Each liquefied matrix, supplemented with either Mycobacterium tuberculosis (MTB) H37Rv strain DNA or intact cells, was aliquoted onto a filter paper embedded with solubilizing agents, and was subsequently dried up. Most of the nucleic acids, including genomic DNA from the bacilli and the host, binds to the filter paper. Next, several protocols were evaluated to elute the DNA from the paper, using qPCR to detect the insertion sequence IS6110, a M. tuberculosis complex genomic marker. The limit of detection (LOD) of the best protocol was then evaluated using parallel seeding and colony counting. The protocol was also evaluated using seventeen sputum samples, previously characterized by the GeneXpert or culture. Two instruments (the ABI7500 Standard and the Q3-Plus system) and two reagents storage formats (frozen or ready-to-use) were evaluated. Solutions containing guanidine isothiocyanate exerted the best liquefying effect on the mucin-based matrix extracted from one 6-mm punches, followed by a brief incubation at 95°C. The resulting DNA contained impurities, but a simple 1:10 dilution elicited the detection of MTB and human genomic targets. The described protocol presented an apparent LOD of 02 CFU/mL of MTB. Challenging the protocol with previously characterized samples showed substantial agreement with GeneXpert MTB/RIF results (sensitivity of 90%, agreement of 88.9%, kappa coefficient of 0.77), and moderate agreement with culture results (sensitivity of 100%, agreement of 78.9%, kappa coefficient of 0.58). This work presents a sensitive proof-of-concept protocol for sputum liquefaction and decontamination followed by a simple DNA extraction procedure, in which the extraction steps are streamlined with a ready-to-use qPCR in a portable instrument that can be employed in low infrastructure settings.


Assuntos
Programas de Rastreamento/métodos , Mycobacterium tuberculosis/isolamento & purificação , Sistemas Automatizados de Assistência Junto ao Leito , Manejo de Espécimes/métodos , Tuberculose Pulmonar/diagnóstico , Brasil , DNA Bacteriano/isolamento & purificação , Humanos , Limite de Detecção , Programas de Rastreamento/economia , Programas de Rastreamento/instrumentação , Mycobacterium tuberculosis/genética , Estudo de Prova de Conceito , Reação em Cadeia da Polimerase em Tempo Real/economia , Reação em Cadeia da Polimerase em Tempo Real/instrumentação , Reação em Cadeia da Polimerase em Tempo Real/métodos , Manejo de Espécimes/economia , Escarro/microbiologia , Tuberculose Pulmonar/microbiologia
9.
J Mol Diagn ; 22(12): 1408-1418, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33011442

RESUMO

Numerous studies have identified essential contributions of altered mitochondrial DNA (mtDNA) copy number and mutations in many common disorders, including cancer. To date, capture-based next-generation sequencing (NGS) has been widely applied to detect mtDNA mutations, although it lacks the ability to assess mtDNA copy number. The current strategy for quantifying mtDNA copy number relies mainly on real-time quantitative PCR, which is limited in degraded samples. A novel capture-based NGS approach was developed using both mtDNA and nuclear DNA probes to capture target fragments, enabling simultaneous detection of mtDNA mutations and copy number in different sample types. First, the impact of selecting reference genes on mtDNA copy number calculation was evaluated, and finally, 3 nuclear DNA fragments of 4000 bp were selected as an internal reference for detection. Then, the effective application of this approach was verified in DNA samples of formalin-fixed, paraffin-embedded specimens and body fluids, indicating the widespread applicability. This approach showed more accurate and stable results in detecting mtDNA copy number compared with real-time quantitative PCR in degraded DNA samples. Moreover, data indicated this approach had good reproducibility in detecting both mtDNA copy number and mutations among three sample types. Altogether, a versatile and cost-effective capture-based NGS approach has been developed for concurrent detection of mtDNA copy number and mutations, which has numerous applications in research and diagnosis.


Assuntos
Variações do Número de Cópias de DNA , DNA Mitocondrial/genética , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Mutação , Neoplasias/genética , Reação em Cadeia da Polimerase em Tempo Real/métodos , Análise de Sequência de DNA/métodos , Linhagem Celular Tumoral , Análise Custo-Benefício , Confiabilidade dos Dados , Sequenciamento de Nucleotídeos em Larga Escala/economia , Humanos , Mitocôndrias/genética , Neoplasias/patologia , Reação em Cadeia da Polimerase em Tempo Real/economia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Análise de Sequência de DNA/economia
10.
CMAJ ; 192(40): E1146-E1155, 2020 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-32907820

RESUMO

BACKGROUND: Testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is largely passive, which impedes epidemic control. We defined active testing strategies for SARS-CoV-2 using reverse transcription polymerase chain reaction (RT-PCR) for groups at increased risk of acquiring SARS-CoV-2 in all Canadian provinces. METHODS: We identified 5 groups who should be prioritized for active RT-PCR testing: contacts of people who are positive for SARS-CoV-2, and 4 at-risk populations - hospital employees, community health care workers and people in long-term care facilities, essential business employees, and schoolchildren and staff. We estimated costs, human resources and laboratory capacity required to test people in each group or to perform surveillance testing in random samples. RESULTS: During July 8-17, 2020, across all provinces in Canada, an average of 41 751 RT-PCR tests were performed daily; we estimated this required 5122 personnel and cost $2.4 million per day ($67.8 million per month). Systematic contact tracing and testing would increase personnel needs 1.2-fold and monthly costs to $78.9 million. Conducted over a month, testing all hospital employees would require 1823 additional personnel, costing $29.0 million; testing all community health care workers and persons in long-term care facilities would require 11 074 additional personnel and cost $124.8 million; and testing all essential employees would cost $321.7 million, requiring 25 965 added personnel. Testing the larger population within schools over 6 weeks would require 46 368 added personnel and cost $816.0 million. Interventions addressing inefficiencies, including saliva-based sampling and pooling samples, could reduce costs by 40% and personnel by 20%. Surveillance testing in population samples other than contacts would cost 5% of the cost of a universal approach to testing at-risk populations. INTERPRETATION: Active testing of groups at increased risk of acquiring SARS-CoV-2 appears feasible and would support the safe reopening of the economy and schools more broadly. This strategy also appears affordable compared with the $169.2 billion committed by the federal government as a response to the pandemic as of June 2020.


Assuntos
Betacoronavirus/isolamento & purificação , Técnicas de Laboratório Clínico/economia , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/economia , Programas de Rastreamento/economia , Pandemias/economia , Pneumonia Viral/diagnóstico , Pneumonia Viral/economia , COVID-19 , Teste para COVID-19 , Canadá , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/prevenção & controle , Humanos , Pandemias/prevenção & controle , Pneumonia Viral/epidemiologia , Pneumonia Viral/prevenção & controle , Reação em Cadeia da Polimerase em Tempo Real/economia , Medição de Risco/economia , Fatores de Risco , SARS-CoV-2
11.
Braz J Microbiol ; 51(3): 1117-1123, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32767275

RESUMO

In March 2020, WHO declared a pandemic state due to SARS-CoV-2 having spread. TaqMan-based real-time RT-qPCR is currently the gold standard for COVID-19 diagnosis. However, it is a high-cost assay, inaccessible for the majority of laboratories around the world, making it difficult to diagnose on a large scale. The objective of this study was to standardize lower cost molecular methods for SARS-CoV-2 identification. E gene primers previously determined for TaqMan assays by Colman et al. (2020) were adapted in SYBR Green assay and RT-PCR conventional. The cross-reactivity test was performed with 17 positive samples for other respiratory viruses, and the sensibility test was performed with 8 dilutions (10 based) of SARS-CoV-2 isolated and 63 SARS-CoV-2-positive samples. The SYBR Green assays and conventional RT-PCR have not shown amplification of the 17 respiratory samples positives for other viruses. The SYBR Green-based assay was able to detect all 8 dilutions of the isolate. The conventional PCR detected until 107 dilution, both assays detected the majority of the 63 samples, 98.42% of positivity in SYBR Green, and 93% in conventional PCR. The average Ct variation between SYBR Green and TaqMan was 1.92 and the highest Ct detected by conventional PCR was 35.98. Both of the proposed assays are less sensitive than the current gold standard; however, our data shows a low sensibility variation, suggesting that these methods could be used by laboratories as a lower cost molecular method for SARS-CoV-2 diagnosis.


Assuntos
Betacoronavirus/isolamento & purificação , Infecções por Coronavirus/diagnóstico , Corantes Fluorescentes/economia , Compostos Orgânicos/economia , Pneumonia Viral/diagnóstico , Reação em Cadeia da Polimerase em Tempo Real/economia , Adolescente , Adulto , Animais , Benzotiazóis , Betacoronavirus/genética , COVID-19 , Criança , Chlorocebus aethiops , Infecções por Coronavirus/economia , Reações Cruzadas , Diaminas , Humanos , Pessoa de Meia-Idade , Nasofaringe/virologia , Orofaringe/virologia , Pandemias/economia , Pneumonia Viral/economia , Quinolinas , RNA Viral/isolamento & purificação , Reação em Cadeia da Polimerase em Tempo Real/métodos , SARS-CoV-2 , Sensibilidade e Especificidade , Células Vero , Adulto Jovem
12.
PLoS One ; 15(7): e0236859, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32730368

RESUMO

BACKGROUND: Corona virus disease 2019 (COVID-19) which initially started as a cluster of pneumonia cases in the Wuhan city of China has now become a full-blown pandemic. Timely diagnosis of COVID-19 is the key in containing the pandemic and breaking the chain of transmission. In low- and middle-income countries availability of testing kits has become the major bottleneck in testing. Novel methods like pooling of samples are the need of the hour. OBJECTIVE: We undertook this study to evaluate a novel protocol of pooling of RNA samples/elutes in performance of PCR for SARS CoV-2 virus. STUDY DESIGN: Extracted RNA samples were randomly placed in pools of 8 on a 96 well plate. Both individual RNA (ID) and pooled RNA RT-qPCR for the screening E gene were done in the same plate and the positivity for the E gene was seen. RESULTS: The present study demonstrated that pool testing with RNA samples can easily detect even up to a single positive sample with Ct value as high as 38. The present study also showed that the results of pool testing is not affected by number of positive samples in a pool. CONCLUSION: Pooling of RNA samples can reduce the time and expense, and can help expand diagnostic capabilities, especially during constrained supply of reagents and PCR kits for the diagnosis of SARS-CoV-2 infection.


Assuntos
Betacoronavirus/genética , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/epidemiologia , Pneumonia Viral/diagnóstico , Pneumonia Viral/epidemiologia , RNA Viral/genética , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , COVID-19 , Proteínas do Envelope de Coronavírus , Infecções por Coronavirus/virologia , Testes Diagnósticos de Rotina/economia , Testes Diagnósticos de Rotina/métodos , Humanos , Índia/epidemiologia , Programas de Rastreamento/economia , Programas de Rastreamento/métodos , Pandemias , Pneumonia Viral/virologia , Estudos Prospectivos , RNA Viral/isolamento & purificação , Reação em Cadeia da Polimerase em Tempo Real/economia , Reprodutibilidade dos Testes , Reação em Cadeia da Polimerase Via Transcriptase Reversa/economia , SARS-CoV-2 , Proteínas do Envelope Viral/genética
13.
PLoS One ; 15(6): e0234682, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32530929

RESUMO

Novel Corona virus/Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2 or 2019-nCoV), and the subsequent disease caused by the virus (coronavirus disease 2019 or COVID-19), is an emerging global health concern that requires a rapid diagnostic test. Quantitative reverse transcription PCR (qRT-PCR) is currently the standard for SARS-CoV-2 detection; however, Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) may allow for faster and cheaper field based testing at point-of-risk. The objective of this study was to develop a rapid screening diagnostic test that could be completed in 30-45 minutes. Simulated patient samples were generated by spiking serum, urine, saliva, oropharyngeal swabs, and nasopharyngeal swabs with a portion of the SARS-CoV-2 nucleic sequence. RNA isolated from nasopharyngeal swabs collected from actual COVID-19 patients was also tested. The samples were tested using RT-LAMP as well as by conventional qRT-PCR. Specificity of the RT-LAMP was evaluated by also testing against other related coronaviruses. RT-LAMP specifically detected SARS-CoV-2 in both simulated patient samples and clinical specimens. This test was performed in 30-45 minutes. This approach could be used for monitoring of exposed individuals or potentially aid with screening efforts in the field and potential ports of entry.


Assuntos
Betacoronavirus/isolamento & purificação , Infecções por Coronavirus/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Pneumonia Viral/diagnóstico , Testes Imediatos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Betacoronavirus/genética , COVID-19 , Infecções por Coronavirus/virologia , Primers do DNA , Humanos , Técnicas de Diagnóstico Molecular/economia , Técnicas de Diagnóstico Molecular/instrumentação , Técnicas de Amplificação de Ácido Nucleico/economia , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Pandemias , Pneumonia Viral/virologia , Reação em Cadeia da Polimerase em Tempo Real/economia , Reação em Cadeia da Polimerase em Tempo Real/instrumentação , SARS-CoV-2 , Sensibilidade e Especificidade , Fatores de Tempo
14.
Biosensors (Basel) ; 10(5)2020 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-32397069

RESUMO

The traditional qPCR instrument is bulky, expensive, and inconvenient to carry, so we report a portable rotary real-time fluorescent PCR (polymerase chain reaction) that completes the PCR amplification of DNA in the field, and the reaction can be observed in real-time. Through the analysis of a target gene, namely pGEM-3Zf (+), the gradient amplification and melting curves are compared to commercial devices. The results confirm the stability of our device. This is the first use of a mechanical rotary structure to achieve gradient amplification curves and melting curves comparable to commercial instruments. The average power consumption of our system is about 7.6 W, which is the lowest energy consumption for real-time fluorescence quantification in shunting PCR and enables the use of our device in the field thanks to its self-contained power supply based on a lithium battery. In addition, all of the equipment costs only about 710 dollars, which is far lower than the cost of a commercial PCR instrument because the control system through mechanical displacement replaces the traditional TEC (thermoelectric cooler) temperature control. Moreover, the equipment has a low technical barrier, which can suit the needs of non-professional settings, with strong repeatability.


Assuntos
Fontes de Energia Elétrica/economia , Fluorescência , Ensaios de Triagem em Larga Escala/economia , Lítio/economia , Reação em Cadeia da Polimerase em Tempo Real/economia , Lítio/química , Temperatura
15.
Med Hypotheses ; 141: 109786, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32361529

RESUMO

Recently, a novel coronavirus (SARS-CoV-2; coronavirus disease 2019, COVID-19) has emerged, rapidly spreading and severely straining the capacity of the global health community. Many nations are employing combinations of containment and mitigation strategies, where early diagnosis of COVID-19 is vital in controlling illness progression and limiting viral spread within the population. Thus, rapid and accurate methods of early detection are vital to contain COVID-19 and prevent further spread and predicted subsequent infectious waves of viral recurrence in future. Immediately after its initial characterization, Chinese and American Centers for Disease Control and Prevention (CDCs) rapidly employed molecular assays for detection of COVID-19, mostly employing real-time polymerase chain reaction (RT-PCR) methods. However, such methods require specific expensive items of equipment and highly trained analysts, requiring upwards of 4-8 h to process. These requirements coupled with associated financial pressures may prevent effective deployment of such diagnostic tests. Loop mediated isothermal amplification(LAMP) is method of nucleic acid amplification which exhibits increased sensitivity and specificity are significantly rapid, and do not require expensive reagents or instruments, which aids in cost reduction for coronavirus detection. Studies have shown the successful application of LAMP assays in various forms to detect coronavirus RNA in patient samples, demonstrating that 1-10 copies of viral RNA template per reaction are sufficient for successful detection, ~100-fold more sensitive than conventional RT-PCR methods. Importantly, studies have also now demonstrated the effectiveness of LAMP methodology in the detection of SARS-CoV-2 RNA at significantly low levels, particularly following numerous improvements to LAMP assay protocols. We hypothesise that recent advancements in enhanced LAMP protocols assay perhaps represent the best chance for a rapid and robust assay for field diagnosis of COVID-19, without the requirement of specialized equipment and highly trained professionals to interpret results. Herein, we present our arguments with a view to disseminate such findings, to assist the combat of this virus that is proving so devastating. We hope that this strategy could be applied rapidly, and confirmed for viability with clinical samples, before being rolled out for mass-diagnostic testing in these current times.


Assuntos
Betacoronavirus/isolamento & purificação , Técnicas de Laboratório Clínico/métodos , Infecções por Coronavirus/diagnóstico , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Pandemias , Pneumonia Viral/diagnóstico , Betacoronavirus/genética , COVID-19 , Teste para COVID-19 , Vacinas contra COVID-19 , Técnicas de Laboratório Clínico/economia , Infecções por Coronavirus/economia , Infecções por Coronavirus/virologia , Primers do DNA , Diagnóstico Precoce , Humanos , Técnicas de Diagnóstico Molecular/economia , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/economia , Técnicas de Amplificação de Ácido Nucleico/métodos , Pandemias/economia , Pneumonia Viral/economia , Pneumonia Viral/virologia , RNA Viral/análise , Reação em Cadeia da Polimerase em Tempo Real/economia , SARS-CoV-2 , Sensibilidade e Especificidade , Fatores de Tempo
16.
Gastrointest Endosc ; 92(3): 524-534.e6, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32360302

RESUMO

BACKGROUND AND AIMS: The novel coronavirus disease 2019 (COVID-19) pandemic has limited endoscopy utilization, causing significant health and economic losses. We aim to model the impact of polymerase chain reaction (PCR) testing into resuming endoscopy practice. METHODS: We performed a retrospective review of endoscopy utilization during the COVID-19 pandemic for a baseline reference. A computer model compared 3 approaches: strategy 1, endoscopy for urgent indications only; strategy 2, testing for semiurgent indications; and strategy 3, testing all patients. Analysis was made under current COVID-19 prevalence and projected prevalence of 5% and 10%. Primary outcomes were number of procedures performed and/or canceled. Secondary outcomes were direct costs, reimbursement, personal protective equipment used, and personnel infected. Disease prevalence, testing accuracy, and costs were obtained from the literature. RESULTS: During the COVID-19 pandemic, endoscopy volume was 12.7% of expected. Strategies 2 and 3 were safe and effective interventions to resume endoscopy in semiurgent and elective cases. Investing 22 U.S. dollars (USD) and 105 USD in testing per patient allowed the completion of 19.4% and 95.3% of baseline endoscopies, respectively. False-negative results were seen after testing 4700 patients (or 3 months of applying strategy 2 in our practice). Implementing PCR testing over 1 week in the United States would require 13 and 64 million USD, with a return of 165 and 767 million USD to providers, leaving 65 and 325 healthcare workers infected. CONCLUSIONS: PCR testing is an effective strategy to restart endoscopic practice in the United States. PCR screening should be implemented during the second phase of the pandemic, once the healthcare system is able to test and isolate all suspected COVID-19 cases.


Assuntos
Betacoronavirus/isolamento & purificação , Técnicas de Laboratório Clínico/economia , Infecções por Coronavirus/diagnóstico , Endoscopia/economia , Custos de Cuidados de Saúde , Pneumonia Viral/diagnóstico , Reação em Cadeia da Polimerase em Tempo Real/economia , Adulto , COVID-19 , Teste para COVID-19 , Infecções por Coronavirus/economia , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/prevenção & controle , Árvores de Decisões , Procedimentos Cirúrgicos Eletivos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias/prevenção & controle , Seleção de Pacientes , Equipamento de Proteção Individual/economia , Pneumonia Viral/epidemiologia , Pneumonia Viral/prevenção & controle , Estudos Retrospectivos , SARS-CoV-2 , Sensibilidade e Especificidade , Estados Unidos
17.
J Med Virol ; 92(10): 2193-2199, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32401343

RESUMO

In the age of a pandemic, such as the ongoing one caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the world faces a limited supply of tests, personal protective equipment, and factories and supply chains are struggling to meet the growing demands. This study aimed to evaluate the efficacy of specimen pooling for testing of SARS-CoV-2 virus, to determine whether costs and resource savings could be achieved without impacting the sensitivity of the testing. Ten previously tested nasopharyngeal and throat swab specimens by real-time polymerase chain reaction (PCR), were pooled for testing, containing either one or two known positive specimens of varying viral concentrations. Specimen pooling did not affect the sensitivity of detecting SARS-CoV-2 when the PCR cycle threshold (Ct) of original specimen was lower than 35. In specimens with low viral load (Ct > 35), 2 of 15 pools (13.3%) were false negative. Pooling specimens to test for Coronavirus Disease 2019 infection in low prevalence (≤1%) areas or in low risk populations can dramatically decrease the resource burden on laboratory operations by up to 80%. This paves the way for large-scale population screening, allowing for assured policy decisions by governmental bodies to ease lockdown restrictions in areas with a low incidence of infection, or with lower-risk populations.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , COVID-19/epidemiologia , Pandemias , Reação em Cadeia da Polimerase em Tempo Real/métodos , SARS-CoV-2/genética , Manejo de Espécimes/métodos , COVID-19/economia , COVID-19/virologia , Teste para COVID-19/economia , Notificação de Doenças/economia , Notificação de Doenças/métodos , Monitoramento Epidemiológico , Humanos , Limite de Detecção , Nasofaringe/virologia , Faringe/virologia , Prevalência , RNA Viral/genética , Reação em Cadeia da Polimerase em Tempo Real/economia , Estudos Retrospectivos , Manejo de Espécimes/economia , Tailândia/epidemiologia , Carga Viral
18.
Expert Rev Mol Diagn ; 20(6): 575-582, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32011193

RESUMO

INTRODUCTION: Among non-small cell lung cancer (NSCLC) patients, there is one molecularly defined subgroup harboring activating mutations in the epidermal growth factor receptor gene (EGFR), which results in constitutive activation of its intrinsic kinase activity. Consistent data have demonstrated that these patients have a better outcome when treated with specific tyrosine-kinase inhibitors (EGFR-TKIs). Therefore, analysis of EGFR mutational status for treatment guidance is mandatory in this context. AREAS COVERED: Herein we review the clinical development and technical features of cobas® EGFR Mutation Test v2 as a companion diagnostic test (CDx) for therapy with EGFR-TKIs, such as gefitinib, in advanced NSCLC. We also discuss the pros and cons of the current version of the CDx and its performance in both tissue and plasma samples. EXPERT OPINION: The RT-PCR based cobas® EGFR Mutation Test v2 is a reliable and rapid solution for EGFR mutational status assessment at the time of diagnosis in advanced NSCLC that allows eligibility of patients for EGFR-TKI treatment. This test determines EGFR mutations with acceptable sensitivity in tissue or plasma samples. Pre-analytical considerations like tumor cell content, tumor burden or location of metastasis should be considered to better interpret results in the clinical contexture.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Análise Mutacional de DNA/métodos , Mutação com Ganho de Função , Genes erbB-2 , Neoplasias Pulmonares/diagnóstico , Terapia de Alvo Molecular , Proteínas de Neoplasias/genética , Reação em Cadeia da Polimerase em Tempo Real/métodos , Antineoplásicos/uso terapêutico , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Carcinoma Pulmonar de Células não Pequenas/genética , Análise Custo-Benefício , Análise Mutacional de DNA/economia , DNA de Neoplasias/genética , DNA de Neoplasias/isolamento & purificação , Receptores ErbB/antagonistas & inibidores , Receptores ErbB/genética , Éxons/genética , Gefitinibe/uso terapêutico , Humanos , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/genética , Proteínas de Neoplasias/antagonistas & inibidores , Inibidores de Proteínas Quinases/uso terapêutico , Reação em Cadeia da Polimerase em Tempo Real/economia , Sensibilidade e Especificidade , Manejo de Espécimes
19.
Sci Rep ; 10(1): 2047, 2020 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-32029837

RESUMO

A critical element in effective wildlife management is monitoring the status of wildlife populations; however, resources to monitor wildlife populations are typically limited. We compared cost effectiveness of three common population estimation methods (i.e. non-invasive DNA sampling, camera sampling, and sampling from trapping) by applying them to wild pigs (Sus scrofa) across three habitats in South Carolina, U.S.A where they are invasive. We used mark-recapture analyses for fecal DNA sampling data, spatially-explicit capture-recapture analyses for camera sampling data, and a removal analysis for removal sampling from trap data. Density estimates were similar across methods. Camera sampling was the least expensive, but had large variances. Fecal DNA sampling was the most expensive, although this technique generally performed well. We examined how reductions in effort by method related to increases in relative bias or imprecision. For removal sampling, the largest cost savings while maintaining unbiased density estimates was from reducing the number of traps. For fecal DNA sampling, a reduction in effort only minimally reduced costs due to the need for increased lab replicates while maintaining high quality estimates. For camera sampling, effort could only be marginally reduced before inducing bias. We provide a decision tree for researchers to help make monitoring decisions.


Assuntos
Animais Selvagens/fisiologia , Monitorização de Parâmetros Ecológicos/métodos , Espécies Introduzidas/estatística & dados numéricos , Sus scrofa/fisiologia , Animais , DNA/isolamento & purificação , Monitorização de Parâmetros Ecológicos/economia , Fezes/química , Densidade Demográfica , Reação em Cadeia da Polimerase em Tempo Real/economia , South Carolina , Gravação em Vídeo/economia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...