Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
2.
Waste Manag ; 58: 25-33, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27687077

RESUMO

A stepwise method for assessment of the HP 12 is proposed and tested with 49 waste samples. The hazard property HP 12 is defined as "Release of an acute toxic gas": waste which releases acute toxic gases (Acute Tox. 1, 2 or 3) in contact with water or an acid. When a waste contains a substance assigned to one of the following supplemental hazards EUH029, EUH031 and EUH032, it shall be classified as hazardous by HP 12 according to test methods or guidelines (EC, 2014a, 2014b). When the substances with the cited hazard statement codes react with water or an acid, they can release HCl, Cl2, HF, HCN, PH3, H2S, SO2 (and two other gases very unlikely to be emitted, hydrazoic acid HN3 and selenium oxide SeO2 - a solid with low vapor pressure). Hence, a method is proposed:For a set of 49 waste, water addition did not produce gas. Nearly all the solid waste produced a gas in contact with hydrochloric acid in 5 min in an automated calcimeter with a volume >0.1L of gas per kg of waste. Since a plateau of pressure is reached only for half of the samples in 5 min, 6 h trial with calorimetric bombs or glass flasks were done and confirmed the results. Identification of the gases by portable probes showed that most of the tested samples emit mainly CO2. Toxic gases are emitted by four waste: metallic dust from the aluminum industry (CO), two air pollution control residue of industrial waste incinerator (H2S) and a halogenated solvent (organic volatile(s) compound(s)). HF has not been measured in these trials started before the present definition of HP 12. According to the definition of HP 12, only the H2S emission of substances with hazard statement EUH031 is accounted for. In view of the calcium content of the two air pollution control residue, the presence of calcium sulphide (EUH031) can be assumed. These two waste are therefore classified potentially hazardous for HP 12, from a total of 49 waste. They are also classified as hazardous for other properties (HP 7, 10and14 for one of them, and HP 10and14 for the other one respectively). Given these results, it can be assumed that few common household and industrial waste will be classified hazardous only by HP 12.


Assuntos
Ecotoxicologia/métodos , Gases , Resíduos Perigosos , Resíduos Industriais , Alumínio , Cloro/química , União Europeia , Gases/análise , Gases/química , Resíduos Perigosos/análise , Resíduos Perigosos/classificação , Ácido Clorídrico/química , Sulfeto de Hidrogênio/análise , Sulfeto de Hidrogênio/química , Incineração , Metalurgia/métodos , Resíduos Sólidos/análise
3.
Waste Manag ; 58: 14-24, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27639283

RESUMO

A new harmonized EU regulation for the classification of waste came into effect on 1st June 2015, in which the criteria and assessment methods for the classification of hazardous waste are harmonized with other internationally agreed-upon systems for hazard classification of chemicals (CLP). However, criteria and guidance for the assessment of ecotoxicological hazard (Hazard Property 14, HP14) are still lacking for waste classification. This paper have evaluated and compared two HP14 classification frameworks: (i) a calculation method (summation) for mixtures, and (ii) leaching tests. The two frameworks were evaluated by surveying and evaluating ecotoxicological data for Cu, Zn, K and Ca species in bottom ash from incinerated waste, together with geochemical speciation modelling. Classification based on the summation method proved to be highly sensitive to the choice of speciation and ecotoxicological classification. This results in a wide range of critical concentrations triggering hazardous classification (in particular for Cu and Zn). Important parameters governing the availability of toxic elements, such as transformation from one species to another and complexation on organic or inorganic sorbents, are not accounted for. Geochemical modelling revealed that a testing strategy built on CLP based leaching tests (liquid/solid ratio (L/S)⩾10,000, pH range 5.5-8.5) avoids bias and is superior to the summation method with respect to both precision and accuracy. A testing strategy built on leaching tests, designed for risk assessment purposes, (L/S ratio of 10, natural pH of the ash) severely underestimate the hazard associated with the presence of toxic compounds (Cu and Zn), while simultaneously falsely indicate a hazardousness due to the presence of non-toxic compounds (Ca and K). However, the testing methods adopted by CLP are problematic from a practical and functional point of view. To conclude, the L/S ratio and pH were found to be critical for hazard classification based on leaching test methods. Further studies are needed to develop a relevant, practical and functional testing strategy for HP14 hazardous waste classification.


Assuntos
Ecotoxicologia/métodos , Resíduos Perigosos/classificação , Biodegradação Ambiental , Cinza de Carvão/química , Ecotoxicologia/normas , União Europeia , Concentração de Íons de Hidrogênio , Metais/análise , Modelos Teóricos , Valores de Referência , Testes de Toxicidade
4.
J Air Waste Manag Assoc ; 65(6): 743-50, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25976487

RESUMO

UNLABELLED: The plasma display panel (PDP) is rapidly becoming obsolete, contributing in large amounts to the electronic waste stream. In order to assess the potential for environmental pollution due to hazardous metals leached from PDP glass, standardized leaching procedures, chemical speciation assessments, and bioavailability tests were conducted. According to the Toxicity Characteristic Leaching Procedure (TCLP), arsenic in back glass was present at 4.46 ± 0.22 mg/L, close to its regulation limit of 5 mg/L. Zn is not available in the TCLP, but its TCLP leaching concentration in back glass is 102.96 ± 5.34 mg/L. This is because more than 90% of Zn is in the soluble and exchangeable and carbonate fraction. We did not detect significant levels of Ag, Ba, or Cu in the TCLP leachate, and the main fraction of Ag and Ba is residual, more than 95%, while the fraction distribution of Cu changes SEP by SEP. Ethylenediamine tetraacetic acid (EDTA)- and diethylenetriamine pentaacetic acid (DTPA)-extractable Ag, As, Ba, Cu, Zn, and Ni indicate a lower biohazards potential. These results show that, according to the EPA regulations, PDP glass may not be classified as hazardous waste because none of the metals exceeded their thresholds in PDP leachate. However, the concentrations of As and Zn should be lowered in the manufacturing process and finished product to avoid potential pollution problems. IMPLICATIONS: The plasma display panel is rapidly becoming obsolete because of the liquid crystal display. In this study, the leachability of heavy metals contained in the waste plasma display panel glass was first examined by standardized leaching tests, typical chemical speciation assessments, and bioavailability tests, providing fundamental data for waste PDP glass recovery, recycling, and reuse.


Assuntos
Resíduo Eletrônico/análise , Poluentes Ambientais/análise , Resíduos Perigosos/classificação , Metais Pesados/análise , Disponibilidade Biológica , China , Monitoramento Ambiental , Política Ambiental , Poluentes Ambientais/metabolismo , Poluentes Ambientais/toxicidade , Vidro/análise , Regulamentação Governamental , Resíduos Perigosos/análise , Humanos , Metais Pesados/metabolismo , Metais Pesados/toxicidade , Estados Unidos
5.
Waste Manag ; 39: 57-62, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25746178

RESUMO

The potential for disposable electronic cigarettes (e-cigarettes) to be classified as hazardous waste was investigated. The Toxicity Characteristic Leaching Procedure (TCLP) was performed on 23 disposable e-cigarettes in a preliminary survey of metal leaching. Based on these results, four e-cigarette products were selected for replicate analysis by TCLP and the California Waste Extraction Test (WET). Lead was measured in leachate as high as 50mg/L by WET and 40mg/L by TCLP. Regulatory thresholds were exceeded by two of 15 products tested in total. Therefore, some e-cigarettes would be toxicity characteristic (TC) hazardous waste but a majority would not. When disposed in the unused form, e-cigarettes containing nicotine juice would be commercial chemical products (CCP) and would, in the United States (US), be considered a listed hazardous waste (P075). While household waste is exempt from hazardous waste regulation, there are many instances in which such waste would be subject to regulation. Manufactures and retailers with unused or expired e-cigarettes or nicotine juice solution would be required to manage these as hazardous waste upon disposal. Current regulations and policies regarding the availability of nicotine-containing e-cigarettes worldwide were reviewed. Despite their small size, disposable e-cigarettes are consumed and discarded much more quickly than typical electronics, which may become a growing concern for waste managers.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Resíduos Perigosos/análise , Eliminação de Resíduos , Resíduos Perigosos/classificação , Resíduos Perigosos/economia , Eliminação de Resíduos/legislação & jurisprudência , Gerenciamento de Resíduos
6.
US Army Med Dep J ; : 25-31, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25651142

RESUMO

Healthcare providers are often surprised that regulations promulgated by the US Environmental Protection Agency (EPA) apply to patient care settings. Many find it strange that processes meant to heal have the potential to harm human health and the environment, and are, therefore, regulated by federal and state environmental agencies. The importance of compliance is emphasized by the fact that both the EPA and individual state agencies have the authority to impose civil and criminal penalties if they discover violations. The Joint Commission considers compliance important enough to include it as an element of performance in the Environment of Care standard.


Assuntos
Poluição Ambiental/legislação & jurisprudência , Resíduos Perigosos/legislação & jurisprudência , Instalações de Saúde/legislação & jurisprudência , Eliminação de Resíduos de Serviços de Saúde/legislação & jurisprudência , Militares , United States Department of Defense/legislação & jurisprudência , United States Environmental Protection Agency/legislação & jurisprudência , Atenção à Saúde , Poluição Ambiental/prevenção & controle , Órgãos Governamentais , Fidelidade a Diretrizes , Resíduos Perigosos/classificação , Humanos , Equipe de Assistência ao Paciente , Governo Estadual , Estados Unidos
7.
Waste Manag ; 34(10): 1739-51, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24994468

RESUMO

Hazard classification of waste is a necessity, but the hazard properties (named "H" and soon "HP") are still not all defined in a practical and operational manner at EU level. Following discussion of subsequent draft proposals from the Commission there is still no final decision. Methods to implement the proposals have recently been proposed: tests methods for physical risks, test batteries for aquatic and terrestrial ecotoxicity, an analytical package for exhaustive determination of organic substances and mineral elements, surrogate methods for the speciation of mineral elements in mineral substances in waste, and calculation methods for human toxicity and ecotoxicity with M factors. In this paper the different proposed methods have been applied to a large assortment of solid and liquid wastes (>100). Data for 45 wastes - documented with extensive chemical analysis and flammability test - were assessed in terms of the different HP criteria and results were compared to LoW for lack of an independent classification. For most waste streams the classification matches with the designation provided in the LoW. This indicates that the criteria used by LoW are similar to the HP limit values. This data set showed HP 14 'Ecotoxic chronic' is the most discriminating HP. All wastes classified as acute ecotoxic are also chronic ecotoxic and the assessment of acute ecotoxicity separately is therefore not needed. The high number of HP 14 classified wastes is due to the very low limit values when stringent M factors are applied to total concentrations (worst case method). With M factor set to 1 the classification method is not sufficiently discriminating between hazardous and non-hazardous materials. The second most frequent hazard is HP 7 'Carcinogenic'. The third most frequent hazard is HP 10 'Toxic for reproduction' and the fourth most frequent hazard is HP 4 "Irritant - skin irritation and eye damage". In a stepwise approach, it seems relevant to assess HP 14 first, then, if the waste is not classified as hazardous, to assess subsequently HP 7, HP 10 and HP 4, and then if still not classified as hazardous, to assess the remaining properties. The elements triggering the HP 14 classification in order of importance are Zn, Cu, Pb, Cr, Cd and Hg. Progress in the speciation of Zn and Cu is essential for HP 14. Organics were quantified by the proposed method (AFNOR XP X30-489) and need no speciation. Organics can contribute significantly to intrinsic toxicity in many waste materials, but they are only of minor importance for the assessment of HP 14 as the metal concentrations are the main HP 14 classifiers. Organic compounds are however responsible for other toxicological characteristics (hormone disturbance, genotoxicity, reprotoxicity…) and shall be taken into account when the waste is not HP 14 classified.


Assuntos
Resíduos Perigosos/classificação , Eliminação de Resíduos/métodos , Eliminação de Resíduos Líquidos/métodos , União Europeia , Resíduos Perigosos/efeitos adversos , Resíduos Perigosos/legislação & jurisprudência
9.
J Hazard Mater ; 260: 157-66, 2013 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-23747474

RESUMO

Ministry of Environment, Republic of Korea (South Korea) is in progress of converting its current hazardous waste classification system to harmonize it with the international standard and to set-up the regulatory standards for toxic substances present in the hazardous waste. In the present work, the concentrations along with the trend of 13 heavy metals, F(-), CN(-) and 19 PAH present in the hazardous waste generated among various thermal processes (11 processes) in South Korea were analyzed along with their leaching characteristics. In all thermal processes, the median concentrations of Cu (3.58-209,000 mg/kg), Ni (BDL-1560 mg/kg), Pb (7.22-5132.25mg/kg) and Zn (83.02-31419 mg/kg) were comparatively higher than the other heavy metals. Iron & Steel thermal process showed the highest median value of the heavy metals Cd (14.76 mg/kg), Cr (166.15 mg/kg) and Hg (2.38 mg/kg). Low molecular weight PAH (BDL-37.59 mg/kg) was predominant in sludge & filter cake samples present in most of the thermal processes. Comparatively flue gas dust present in most of the thermal processing units resulted in the higher leaching of the heavy metals.


Assuntos
Resíduos Perigosos/classificação , Eliminação de Resíduos/métodos , Cobre/análise , Monitoramento Ambiental , Resíduos Perigosos/análise , Concentração de Íons de Hidrogênio , Resíduos Industriais , Ferro/análise , Chumbo/análise , Metais Pesados , Análise Multivariada , Níquel/análise , República da Coreia , Esgotos , Aço/análise , Zinco/análise
10.
Waste Manag ; 33(7): 1577-88, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23602301

RESUMO

The classification of waste as hazardous could soon be assessed in Europe using largely the hazard properties of its constituents, according to the the Classification, Labelling and Packaging (CLP) regulation. Comprehensive knowledge of the component constituents of a given waste will therefore be necessary. An analytical protocol for determining waste composition is proposed, which includes using inductively coupled plasma (ICP) screening methods to identify major elements and gas chromatography/mass spectrometry (GC-MS) screening techniques to measure organic compounds. The method includes a gross or indicator measure of 'pools' of higher molecular weight organic substances that are taken to be less bioactive and less hazardous, and of unresolved 'mass' during the chromatography of volatile and semi-volatile compounds. The concentration of some elements and specific compounds that are linked to specific hazard properties and are subject to specific regulation (examples include: heavy metals, chromium(VI), cyanides, organo-halogens, and PCBs) are determined by classical quantitative analysis. To check the consistency of the analysis, the sum of the concentrations (including unresolved 'pools') should give a mass balance between 90% and 110%. Thirty-two laboratory samples comprising different industrial wastes (liquids and solids) were tested by two routine service laboratories, to give circa 7000 parameter results. Despite discrepancies in some parameters, a satisfactory sum of estimated or measured concentrations (analytical balance) of 90% was reached for 20 samples (63% of the overall total) during this first test exercise, with identified reasons for most of the unsatisfactory results. Regular use of this protocol (which is now included in the French legislation) has enabled service laboratories to reach a 90% mass balance for nearly all the solid samples tested, and most of liquid samples (difficulties were caused in some samples from polymers in solution and vegetable oil). The protocol is submitted to French and European normalization bodies (AFNOR and CEN) and further improvements are awaited.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Resíduos Perigosos/classificação , Resíduos Industriais/análise , Gerenciamento de Resíduos/métodos , Europa (Continente) , França , Resíduos Perigosos/análise , Concentração de Íons de Hidrogênio , Metais/análise , Bifenilos Policlorados/análise , Resíduos Sólidos/análise , Resíduos Sólidos/classificação , Compostos Orgânicos Voláteis/análise
12.
Environ Sci Pollut Res Int ; 20(4): 2087-97, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23417361

RESUMO

The sustainable management of chemicals and their associated wastes-especially legacy stockpiles-is always challenging. Developing countries face particular difficulties as they often have insufficient treatment and disposal capacity, have limited resources and many lack an appropriate and effective regulatory framework. This paper describes the objectives and the approach of the Egyptian-German Twinning Project under the European Neighbourhood Policy to improve the strategy of managing hazardous substances in the Egyptian Environmental Affairs Agency (EEAA) between November 2008 and May 2011. It also provides an introduction to the Republic of Egypt's legal and administrative system regarding chemical controls. Subsequently, options for a new chemical management strategy consistent with the recommendations of the United Nations Chemicals Conventions are proposed. The Egyptian legal and administrative system is discussed in relation to the United Nations' recommendations and current European Union legislation for the sound management of chemicals. We also discuss a strategy for the EEAA to use the existing Egyptian legal system to implement the United Nations' Globally Harmonized System of Classification and Labelling of Chemicals, the Stockholm Convention and other proposed regulatory frameworks. The analysis, the results, and the recommendations presented may be useful for other developing countries in a comparable position to Egypt aspiring to update their legislation and administration to the international standards of sound management of chemicals.


Assuntos
Segurança Química/legislação & jurisprudência , Países em Desenvolvimento , Política Ambiental/legislação & jurisprudência , Substâncias Perigosas , Resíduos Perigosos/legislação & jurisprudência , Gerenciamento de Resíduos/legislação & jurisprudência , Fortalecimento Institucional , Segurança Química/métodos , Segurança Química/normas , Egito , União Europeia , Alemanha , Guias como Assunto , Substâncias Perigosas/classificação , Resíduos Perigosos/classificação , Resíduos Perigosos/prevenção & controle , Nações Unidas , Gerenciamento de Resíduos/métodos , Gerenciamento de Resíduos/normas
13.
Waste Manag ; 32(12): 2208-17, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22917872

RESUMO

In this study we describe the development of an alternative methodology for hazard characterization of waste materials. Such an alternative methodology for hazard assessment of complex waste materials is urgently needed, because the lack of a validated instrument leads to arbitrary hazard classification of such complex waste materials. False classification can lead to human and environmental health risks and also has important financial consequences for the waste owner. The Hazardous Waste Directive (HWD) describes the methodology for hazard classification of waste materials. For mirror entries the HWD classification is based upon the hazardous properties (H1-15) of the waste which can be assessed from the hazardous properties of individual identified waste compounds or--if not all compounds are identified--from test results of hazard assessment tests performed on the waste material itself. For the latter the HWD recommends toxicity tests that were initially designed for risk assessment of chemicals in consumer products (pharmaceuticals, cosmetics, biocides, food, etc.). These tests (often using mammals) are not designed nor suitable for the hazard characterization of waste materials. With the present study we want to contribute to the development of an alternative and transparent test strategy for hazard assessment of complex wastes that is in line with the HWD principles for waste classification. It is necessary to cope with this important shortcoming in hazardous waste classification and to demonstrate that alternative methods are available that can be used for hazard assessment of waste materials. Next, by describing the pros and cons of the available methods, and by identifying the needs for additional or further development of test methods, we hope to stimulate research efforts and development in this direction. In this paper we describe promising techniques and argument on the test selection for the pilot study that we have performed on different types of waste materials. Test results are presented in a second paper. As the application of many of the proposed test methods is new in the field of waste management, the principles of the tests are described. The selected tests tackle important hazardous properties but refinement of the test battery is needed to fulfil the a priori conditions.


Assuntos
Poluentes Ambientais/toxicidade , Resíduos Perigosos/classificação , Testes de Toxicidade/métodos , Bioensaio , Linhagem Celular Tumoral , Poluentes Ambientais/química , Feminino , Humanos , Eliminação de Resíduos Líquidos/métodos
14.
Waste Manag ; 32(12): 2218-28, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22770807

RESUMO

The Hazardous Waste Directive (HWD, Council Directive 91/689/EC, 1991) provides a framework for classification of hazardous waste, based on 15 Hazard (H)-criteria. For complex wastes the HWD foresees the application of toxicity tests on the waste material itself to assess its toxic properties. However, these proposed test methods often involve mammalian testing, which is not acceptable from an ethical point of view, nor is it feasible economically. The DISCRISET project was initiated to investigate the use of alternative chemical and biological fast screening tests for waste hazard classification. In the first part of the project, different methods were reviewed and a testing strategy was proposed to minimize time and cost of analysis by a tiered approach. This includes as a first tier chemical analysis followed by a general acute toxicity screen as a second tier and as a third tier mechanistic toxicity tests to assess chronic toxicity (genotoxicity, hormone disturbance, teratogenic effects, immunologic activity). In this phase of the project, selected methods were applied to 16 different waste samples from various sources and industries. The first tier chemical tests are recommended for the full characterization of the leachate fraction (inorganics) but not for the organic fraction of samples. Here the chemical characterization is only useful if toxic content is known or suspected. As second tier the fast bacterial test Microtox is validated as a general toxicity screen for the organic fraction (worst case organic extract). Samples that are not classified in tier 1 or 2 are then further investigated in the third tier by the mechanistic toxicity tests and tested for their potential chronic toxicity: immune activity (TNF-α upregulation) is indicative for corrosive, irritating or sensitising effects (H4/H8/H15), reproductive effects (H10) are indicated by hormone disturbance and early life stage abnormalities in fish larvae when exposed to the extracts and mutagenicity and carcinogenicity (H7, H11) are indicated by SOS response induction and increased mutation frequency in the Ames test when exposed to the extracts. Results indicate that the combination of chemical tests and bioassays allows important hazardous properties to be addressed and the tiered approach ensures that the tests are performed quickly and economically. The suggested strategy provides a solid and ethical alternative to the methods described in the HWD and is a vast improvement on the current, arbitrary classification.


Assuntos
Poluentes Ambientais/toxicidade , Resíduos Perigosos/classificação , Testes de Toxicidade/métodos , Bioensaio , Poluentes Ambientais/química , Projetos Piloto , Fatores de Tempo
15.
Am J Disaster Med ; 7(1): 5-29, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22649865

RESUMO

OBJECTIVE: To provide specific guidance and resources for systematic and orderly decontamination of human remains resulting from a chemical terrorist attack or accidental chemical release. DESIGN: A detailed review and health-based decision criteria protocol is summarized. Protocol basis and logic are derived from analyses of compound-specific toxicological data and chemical/physical characteristics. SETTING: Guidance is suitable for civilian or military settings where human remains potentially contaminated with hazardous chemicals may be present, such as sites of transportation accidents, terrorist operations, or medical examiner processing points. PATIENTS AND PARTICIPANTS: Guidance is developed from data-characterizing controlled experiments with laboratory animals, fabrics, and materiel. MAIN OUTCOME MEASURE(S): Logic and specific procedures for decontamination and management of remains, protection of mortuary affairs personnel, and decision criteria to determine when remains are sufficiently decontaminated are presented. RESULTS: Established procedures as well as existing materiel and available equipment for decontamination and verification provide reasonable means to mitigate chemical hazards from chemically exposed remains. Unique scenarios such as those involving supralethal concentrations of certain liquid chemical warfare agents may prove difficult to decontaminate but can be resolved in a timely manner by application of the characterized systematic approaches. Decision criteria and protocols to "clear" decontaminated remains for transport and processing are also provided. CONCLUSIONS: Once appropriate decontamination and verification have been accomplished, normal procedures for management of remains and release can be followed.


Assuntos
Defesa Civil/organização & administração , Descontaminação/métodos , Exumação/métodos , Fidelidade a Diretrizes , Substâncias Perigosas/classificação , Resíduos Perigosos/classificação , Autopsia , Biodegradação Ambiental , Planejamento em Desastres/organização & administração , Patologia Legal/métodos , Humanos , Gestão da Segurança/organização & administração
16.
Waste Manag Res ; 29(8): 791-6, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21382873

RESUMO

In the present study, the amounts of medical waste materials, sharps, liquid waste, hazardous waste, household waste and recyclables generated from 375 healthcare services including private hospitals, state hospitals, university hospitals, private medical centres, dialysis centres, cottage hospitals and private dentist surgeries were determined, and the relation between the amount of the waste and the bed capacities, inpatient and outpatient numbers were evaluated. The amount of regulated medical waste corresponded to 28.8% of the total waste streams collected from the healthcare services, and the major producers were private hospitals. The major producers of hazardous waste were state hospitals with a generation rate of 57.9%. The main results of the study indicate that the quantities of the waste streams generated from healthcare services in accordance with the outpatient number gave more appropriate results than the other evaluation methods. Furthermore, evaluation based on the bed capacities gave reasonable results except for recyclables and hazardous waste. As a result of the evaluation of the medical waste generation rate with bed capacities, the generation rate was determined as 2.11 ± 3.83 kg bed(-1) day(-1) and this rate was 1.45 ± 9.84 kg outpatient(-1) day(-1) for the evaluation by outpatient numbers. The observed significant P values (P > 0.05) indicate that the evaluation of the waste streams in healthcare services based upon outpatient numbers did not show any reasonable change according to service category.


Assuntos
Resíduos de Serviços de Saúde/análise , Instituições de Assistência Ambulatorial , Cidades , Instalações Odontológicas , Resíduos Perigosos/análise , Resíduos Perigosos/classificação , Resíduos Perigosos/estatística & dados numéricos , Tamanho das Instituições de Saúde , Hospitais , Edifícios de Consultórios Médicos , Resíduos de Serviços de Saúde/classificação , Resíduos de Serviços de Saúde/estatística & dados numéricos , Turquia
17.
Waste Manag Res ; 29(8): 807-14, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21242177

RESUMO

The accurate calculation of the unit generation rates and composition of medical waste generated from medical facilities is necessary in order to design medical waste treatment systems. In this work, the unit medical waste generation rates of 95 public and private medical facilities in the Attica region were calculated based on daily weight records from a central medical waste incineration facility. The calculated medical waste generation rates (in kg bed(-1) day( -1)) varied widely with average values at 0.27 ± 113% and 0.24 ± 121%, for public and private medical facilities, respectively. The hazardous medical waste generation was measured, at the source, in the 40 bed hospital of the island of Ikaria for a period of 42 days during a 6 month period. The average hazardous medical waste generation rate was 1.204 kg occupied bed(-1) day(-1) or 0.33 kg (official) bed( -1) day(-1). From the above amounts, 54% resulted from the patients' room (solid and liquid wastes combined), 24% from the emergency department (solid waste), 17% from the clinical pathology lab and 6% from the X-ray lab. In average, 17% of the total hazardous medical waste was solely infectious. Conclusively, no correlation among the number of beds and the unit medical waste generation rate could be established. Each hospital should be studied separately, since medical waste generation and composition depends on the number and type of departments/laboratories at each hospital, number of external patients and number of occupied beds.


Assuntos
Resíduos Perigosos/análise , Eliminação de Resíduos de Serviços de Saúde , Resíduos de Serviços de Saúde/análise , Grécia , Resíduos Perigosos/classificação , Resíduos Perigosos/estatística & dados numéricos , Número de Leitos em Hospital , Hospitais , Resíduos de Serviços de Saúde/classificação , Resíduos de Serviços de Saúde/estatística & dados numéricos
18.
Chemosphere ; 82(7): 1017-23, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21087786

RESUMO

The leachates from 22 municipal solid waste (MSW) landfill sites in Southern Poland were characterized by evaluation of chemical, microbiological and ecotoxicological parameters. Chemical analyses were mainly focused on the identification of the priority hazardous substances according to Directive on Priority Substances, 2008/105/EC (a daughter directive of the WFD) in leachates. As showed, only five substances (Cd, Hg, hexachlorobutadiene, pentachlorobenzene and PAHs) were detected in the leachates. The compounds tested were absent or present at very low concentrations. Among them, only PAHs were found in all samples in the range from 0.057 to 77.2 µg L⁻¹. The leachates were contaminated with bacteria, including aerobic, psychrophilic and mesophilic bacteria, coliform and fecal coliforms, and spore-forming-bacteria, including Clostridium perfringens, and with filamentous fungi. From the analysis of specific microorganism groups (indicators of environmental pollution by pathogenic or opportunistic pathogenic organisms) it can be concluded that the landfill leachates showed sanitary and epidemiological hazard. In the ecotoxicological study, a battery of tests comprised of 5 bioassays, i.e. Microtox(®), Spirotox, Rotoxkit F™, Thamnotoxkit F™ and Daphtoxkit F™ magna was applied. The leachate samples were classified as toxic in 13.6%, highly toxic in 54.6% and very highly toxic in 31.8%. The Spirotox test was the most sensitive bioassay used. The percentage of class weight score was very high - above 60%; these samples could definitely be considered seriously hazardous and acutely toxic to the fauna and microflora. No correlations were found between the toxicity values and chemical parameters. The toxicity of leachate samples cannot be explained by low levels of the priority pollutants. It seems that other kinds of xenobiotics present in the samples at subacute levels gave the high aggregate toxic effect. The chemical, ecotoxicological and microbiological parameters of the landfill leachates should be analyzed together to assess the environmental risk posed by landfill emissions.


Assuntos
Substâncias Perigosas/toxicidade , Resíduos Perigosos/análise , Poluentes Químicos da Água/toxicidade , Bactérias/efeitos dos fármacos , Butadienos/análise , Butadienos/toxicidade , Cádmio/análise , Cádmio/toxicidade , Clorobenzenos/análise , Clorobenzenos/toxicidade , Clostridium perfringens/efeitos dos fármacos , Monitoramento Ambiental , Fungos/efeitos dos fármacos , Substâncias Perigosas/análise , Substâncias Perigosas/classificação , Resíduos Perigosos/classificação , Resíduos Perigosos/legislação & jurisprudência , Mercúrio/análise , Mercúrio/toxicidade , Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/toxicidade , Eliminação de Resíduos , Medição de Risco/métodos , Microbiologia da Água , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/classificação
19.
Environ Sci Technol ; 45(1): 320-7, 2011 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-21138290

RESUMO

Light-emitting diodes (LEDs) are advertised as environmentally friendly because they are energy efficient and mercury-free. This study aimed to determine if LEDs engender other forms of environmental and human health impacts, and to characterize variation across different LEDs based on color and intensity. The objectives are as follows: (i) to use standardized leachability tests to examine whether LEDs are to be categorized as hazardous waste under existing United States federal and California state regulations; and (ii) to use material life cycle impact and hazard assessment methods to evaluate resource depletion and toxicity potentials of LEDs based on their metallic constituents. According to federal standards, LEDs are not hazardous except for low-intensity red LEDs, which leached Pb at levels exceeding regulatory limits (186 mg/L; regulatory limit: 5). However, according to California regulations, excessive levels of copper (up to 3892 mg/kg; limit: 2500), Pb (up to 8103 mg/kg; limit: 1000), nickel (up to 4797 mg/kg; limit: 2000), or silver (up to 721 mg/kg; limit: 500) render all except low-intensity yellow LEDs hazardous. The environmental burden associated with resource depletion potentials derives primarily from gold and silver, whereas the burden from toxicity potentials is associated primarily with arsenic, copper, nickel, lead, iron, and silver. Establishing benchmark levels of these substances can help manufacturers implement design for environment through informed materials substitution, can motivate recyclers and waste management teams to recognize resource value and occupational hazards, and can inform policymakers who establish waste management policies for LEDs.


Assuntos
Resíduo Eletrônico/análise , Substâncias Perigosas/análise , Resíduos Perigosos/análise , Iluminação , Metais/análise , Conservação dos Recursos Naturais , Resíduo Eletrônico/classificação , Resíduo Eletrônico/estatística & dados numéricos , Meio Ambiente , Monitoramento Ambiental , Substâncias Perigosas/toxicidade , Resíduos Perigosos/classificação , Resíduos Perigosos/estatística & dados numéricos , Chumbo/análise , Chumbo/toxicidade , Metais/toxicidade , Medição de Risco , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/toxicidade
20.
Waste Manag ; 31(3): 536-43, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20952178

RESUMO

Through an agreement with EEE producers, Swedish municipalities are responsible for collection of hazardous waste and waste electrical and electronic equipment (WEEE). In most Swedish municipalities, collection of these waste fractions is concentrated to waste recycling centres where households can source-separate and deposit hazardous waste and WEEE free of charge. However, the centres are often located on the outskirts of city centres and cars are needed in order to use the facilities in most cases. A full-scale experiment was performed in a residential area in southern Sweden to evaluate effects of a system for property-close source separation of hazardous waste and WEEE. After the system was introduced, results show a clear reduction in the amount of hazardous waste and WEEE disposed of incorrectly amongst residual waste or dry recyclables. The systems resulted in a source separation ratio of 70 wt% for hazardous waste and 76 wt% in the case of WEEE. Results show that households in the study area were willing to increase source separation of hazardous waste and WEEE when accessibility was improved and that this and similar collection systems can play an important role in building up increasingly sustainable solid waste management systems.


Assuntos
Eletrônica , Resíduos Perigosos/análise , Eliminação de Resíduos/métodos , Gerenciamento de Resíduos/métodos , Resíduos Perigosos/classificação , Suécia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...