Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Eur J Prosthodont Restor Dent ; 31(4): 424-431, 2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-37318323

RESUMO

To assess the clinical periodontal status of abutment teeth in regards of different design components of distal-extension removable partial dentures. Subjects (N=100) with acrylic or cobalt-chromium distal-extension removable partial dentures were enrolled and their periodontal parameters plaque and gingival indices [PI, GI], probing depths [PD], clinical attachment loss [CAL] and a mobility index [MI] evaluated. Denture base type, major connector, occlusal rests position, design of direct retainers, retention, stability and denture wearing habits were further evaluated. Acrylic RPDs were associated with higher mean±SE PI [1.70±0.74], GI [1.76±0.55], PD scores [2.47±1.02 mm] and CAL values [4.46±2.11 mm] compared to CO-CR RPDs [p⟨0.05]. For abutments, the PI [1.6±0.83], GI [1.72±0.57], PD [2.32±1.03] and CAL [4.26±2.08] were higher than their non-abutments counterparts [p⟨0.05]. CAL scores were found to be significantly higher for mandibular abutments compared to maxillary ones [P=0.002]. The highest PI [1.83±1.10] and GI [2.00±0.00] scores were associated with lingual bars and horse-shoe connectors, respectively. Full palatal coverage and lingual plates were associated with the highest PD [2.80±0.48] and CAL [4.70±0.37] scores. Acrylic RPDs, type of major connector, wrought wire clasps and distal occlusal rests may be considered as risk factors for periodontal disease progression in distal-extension removable partial denture wearers.


Assuntos
Prótese Parcial Removível , Doenças Periodontais , Dente , Humanos , Prótese Parcial Removível/efeitos adversos , Estudos Transversais , Dente Suporte , Doenças Periodontais/etiologia , Retenção de Dentadura/efeitos adversos
2.
Biomed Mater Eng ; 30(4): 439-448, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31476144

RESUMO

BACKGROUND: Adhesion strength of orthodontic attachments to enamel should be within optimal range to resist occlusal forces and to allow debonding without enamel damage. OBJECTIVE: The present study compared the effect of non-thermal plasma (NTP) and conventional surface treatment on the adhesion strength of orthodontic bracket to enamel. METHODS: A total of 100 premolar teeth were allocated into 5 groups according to the bonding procedure followed: Group 1 (Etch, prime and composite adhesive); Group 2 (Prime and composite adhesive); Group 3 (Glass ionomer cement); Group 4 (NTP, prime and composite adhesive) and Group 5 (NTP and glass ionomer cement). Ten specimens in each group were subjected to artificial aging and the remaining ten specimens served as baseline specimens. Adhesion strength values were recorded after debonding and bond failure types were scored. Water contact angles of the NTP treated and untreated enamel surface were measured. RESULTS: Group 1 specimen demonstrated highest bond strength at baseline (21.5 ± 3.01) and thermocycling (15.8 ± 2.87) and the least values were in Group 2 specimens at baseline (3.9 ± 1.01) and thermocycling (1.6 ± 0.7). Among the experimental (NTP) groups, Group 4 specimens exhibited high adhesion strength at baseline (10.2 ± 1.76) and after thermocycling (9.8 ± 2.15) compared to Group 5 specimens at baseline (10.1 ± 1.05) and thermocycling (6.5 ± 2.19). The water contact angle on untreated enamel surface was 53.1° ± 2.1° as compared to 1.4° ± 0.7° in treated surface. CONCLUSION: Non-thermal plasma (NTP) treatment in conjunction with composite adhesives demonstrated clinically acceptable adhesion strength and was well within the optimal range (7-14 MPa) for enamel bonding.


Assuntos
Adesivos/química , Esmalte Dentário/química , Braquetes Ortodônticos , Adesividade , Análise do Estresse Dentário , Retenção de Dentadura/efeitos adversos , Cimentos de Ionômeros de Vidro/química , Humanos , Teste de Materiais , Braquetes Ortodônticos/efeitos adversos , Gases em Plasma , Cimentos de Resina/química
3.
J Prosthodont ; 27(6): 535-543, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28985448

RESUMO

PURPOSE: The aim of this systematic review was to investigate the survival and complication rates of all-ceramic resin-bonded fixed dental prostheses (RBFDPs). MATERIALS AND METHODS: The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were applied. A systematic search was conducted by an electronic search in PubMed, EMBASE, Cochrane Library, and CNKI databases complemented by a manual search. Only clinical studies on all-ceramic RBFDPs with a mean follow-up period of at least 3 years qualified for data analyses. RESULTS: Among 1503 screened articles, one randomized controlled trial (RCT) and seven prospective or retrospective cohort studies were included in this study. The estimated 5-year survival rate of all-ceramic RBFDPs was 91.2%. Debonding and framework fracture were the two most frequent technical complications, and the estimated 5-year debonding rate and fracture rate were 12.2% and 4.8%, respectively. Additionally, cantilevered all-ceramic RBFDPs had a higher survival rate (p < 0.01), lower debonding rate, (p < 0.05), and fracture rate (p < 0.01) compared with two-retainer all-ceramic RBFDPs. Zirconia ceramic RBFDPs had a lower incidence of failure but a higher debonding rate compared with glass-ceramic RBFDPs (p < 0.01). CONCLUSION: Within the limitations of this systematic review, although all-ceramic RBFDPs have a favorable 5-year survival rate, this rate cannot represent the complete success of the treatment, since it may include typical complications such as debonding and fractures. There is an urgent need for long-term clinical studies, especially for well-designed RCTs on all-ceramic RBFDPs.


Assuntos
Cerâmica/uso terapêutico , Colagem Dentária , Retenção de Dentadura , Dentaduras , Resinas Sintéticas/uso terapêutico , Colagem Dentária/efeitos adversos , Colagem Dentária/métodos , Falha de Restauração Dentária , Retenção de Dentadura/efeitos adversos , Retenção de Dentadura/métodos , Dentaduras/efeitos adversos , Humanos , Resinas Sintéticas/efeitos adversos
4.
J Prosthet Dent ; 117(6): 702-705, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27881241

RESUMO

Various pressure-indicating media are available to assess the adaptation of the intaglio surface of a removable dental prosthesis at the insertion and follow-up appointments. This clinical report describes the use of an elastomer that entered the maxillary sinus through an undetected oroantral communication at the 24-hour follow-up for an immediate maxillary complete removable dental prosthesis. A Caldwell-Luc sinusotomy procedure was required to remove the material, and the patient required over 1 year of healing time before his reported symptoms resolved.


Assuntos
Retenção de Dentadura/efeitos adversos , Prótese Total Imediata/efeitos adversos , Prótese Total Superior/efeitos adversos , Prótese Parcial Removível/efeitos adversos , Elastômeros/uso terapêutico , Idoso , Adaptação Marginal Dentária , Retenção de Dentadura/métodos , Elastômeros/efeitos adversos , Humanos , Masculino , Seio Maxilar/diagnóstico por imagem , Seio Maxilar/cirurgia , Tomografia Computadorizada por Raios X
6.
Clin Oral Implants Res ; 26(2): 149-56, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24372952

RESUMO

OBJECTIVES: Narrow-diameter implants (NDIs) are used in severely resorbed mandibles. The reduced implant diameter means a reduction in the total contact surface between the implant and bone. The question arises whether the implant can be sufficiently osseointegrated to withstand loading forces. If not, marginal bone loss can result from overload. The aim of this retrospective study was to compare clinical and radiographic measurements and patient satisfaction of NDIs with those of regular-diameter implants (RDIs) placed in edentulous patients to support an overdenture via either a ball or a locator connection. MATERIAL AND METHODS: Retrospectively over a 7-year period, a total 119 patients fulfilled the inclusion criteria and were selected for this study. The patients received two 3.3- or 4.1-mm-diameter standard titanium implants in the mandible to support an overdenture. At maintenance examinations after 1 and 3 years, clinical peri-implant and prosthetic conditions, marginal bone (MB) and patient satisfaction were investigated. RESULTS: None of the 238 implants were lost during the 3-year follow-up period. Overall MB loss was statistically higher in the NDI group when compared with the RDI group. At the site level, a greater MB loss was observed at the distal side of both implant types. Implants with a locator showed significantly greater MB loss (0.38 mm) compared with the implants with a ball attachment (0.14 mm) over the two-year evaluation period (P = 0.006). Patient satisfaction significantly favoured the NDI (8.3) and the locator attachment (8.6). CONCLUSIONS: The results suggest that during the first three years after implantation, NDIs were associated with more marginal bone loss compared with RDIs. Regardless of implant diameter, the locator attachment showed more marginal bone loss over time compared with the ball attachment.


Assuntos
Perda do Osso Alveolar/diagnóstico por imagem , Implantação Dentária Endóssea/instrumentação , Implantes Dentários/efeitos adversos , Prótese Dentária Fixada por Implante/instrumentação , Retenção de Dentadura/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Perda do Osso Alveolar/etiologia , Planejamento de Prótese Dentária , Retenção de Dentadura/efeitos adversos , Feminino , Seguimentos , Humanos , Arcada Edêntula/diagnóstico por imagem , Arcada Edêntula/cirurgia , Masculino , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia , Pessoa de Meia-Idade , Osseointegração , Satisfação do Paciente , Estudos Retrospectivos , Titânio
7.
J Oral Rehabil ; 39(5): 384-90, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22289034

RESUMO

Residual ridge resorption in the mandible after tooth loss may lead to worsening of complete denture stability and to various subjective complaints. The aim was to evaluate the association between radiologically assessed residual ridge resorption in the mandible, clinically assessed stability of lower complete denture and subjective complaints among elderly denture wearers. The study population consisted of 326 (115 men and 211 women) edentulous subjects aged 60-78years, all of whom were wearing complete dentures in the mandible. Data on subjective complaints were obtained from questionnaires and interviews. Denture stability was assessed clinically. Residual ridge resorption was analysed from panoramic radiographs. The results showed that women were significantly more often satisfied with their lower dentures and reported fewer problems with eating than men. They also had significantly more often residual ridge resorption than men. Among women, residual ridge resorption was significantly associated with poor chewing ability, low satisfaction with dentures and poor denture stability. Among men, residual ridge resorption did not associate with subjective complaints or denture stability. Poor satisfaction with dentures associated significantly with poor denture stability in both genders. In conclusion, these results highlight the importance of denture maintenance treatment. As the extent of residual ridge resorption in the mandible was the most important factor that increased dissatisfaction with lower complete dentures, it is also important to inhibit the progression of resorption by preventing tooth loss or by using implant-retained dentures.


Assuntos
Perda do Osso Alveolar/complicações , Retenção de Dentadura/efeitos adversos , Prótese Total Inferior/efeitos adversos , Doenças Mandibulares/complicações , Satisfação do Paciente , Idoso , Perda do Osso Alveolar/diagnóstico por imagem , Retenção de Dentadura/psicologia , Prótese Total Inferior/psicologia , Feminino , Humanos , Arcada Edêntula/reabilitação , Masculino , Doenças Mandibulares/diagnóstico por imagem , Pessoa de Meia-Idade , Radiografia , Inquéritos e Questionários , Resultado do Tratamento
8.
J Can Dent Assoc ; 76: a52, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20943036

RESUMO

Open-field aluminum-nickle-cobalt magnets have been used in prosthodontics for many years, but success has been limited because these magnets are susceptible to corrosion by the saliva and because their retentive force is weak relative to the initial retention offered by mechanical attachments. More recently, magnets have been made from alloys of the rare earth elements samarium and neodymium, which provide stronger magnetic force per unit size. In addition, a new generation of laser-welded containers has improved protection from salivary corrosion. The current resurgence of interest in this type of attachment appears justified because, unlike mechanical attachments, magnets have potential for unlimited durability and might therefore be superior to mechanical ball or bar attachments for the retention of removable prostheses on implants. To date, no long-term prospective trials have been conducted to confirm the clinical durability of this new generation of magnets for retaining dentures on either teeth or implants. The aim of this study was to document initial clinical experiences and levels of satisfaction among edentulous patients treated with mandibular implant-supported overdentures retained using a new generation of rare-earth magnetic attachments. At the outset, all but one of the 17 patients had had several years of experience with implant-supported overdentures. During the first year, the mean overall satisfaction among these 17 patients increased from less than 70 to over 90 out of 100 (standardized visual analogue scale). No unusual difficulties were encountered in rendering the treatment or maintaining the attachments. This report offers preliminary evidence of the excellent potential of these magnets for retaining mandibular implant-supported overdentures.


Assuntos
Prótese Dentária Fixada por Implante , Retenção de Dentadura/instrumentação , Revestimento de Dentadura , Magnetismo/instrumentação , Contraindicações , Corrosão , Placa Dentária/etiologia , Soldagem em Odontologia , Retenção de Dentadura/efeitos adversos , Humanos , Lasers , Imageamento por Ressonância Magnética , Mandíbula , Neodímio , Satisfação do Paciente , Samário , Soldagem
9.
Am J Med Sci ; 340(2): 164-8, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20555248

RESUMO

INTRODUCTION: Human stores of zinc and copper exist in dynamic equilibrium; an increase in one causes a fall in the other, and clinical consequences of toxicity or deficiency of one or the other may result. Some of the most widely used denture adhesives are zinc based, creating a potential for zinc toxicity and corresponding copper deficiency. A case of denture adhesive-based zinc toxicity with corresponding copper deficiency leading to fatal ascending sensorimotor polyneuropathy was identified. The objectives of this study were to illustrate the evolution, and disparate response to treatment, of neurologic and hematologic abnormalities resulting from copper deficiency, and to discuss opportunities to mitigate denture adhesive-related zinc toxicity. METHODS: Detailed clinical and laboratory data for the subject patient were compiled. The patient received copper supplementation. Copper and zinc levels were obtained posttreatment at varying intervals. RESULTS: Hematologic and neurologic abnormalities progressed, as excessive use of zinc-based denture adhesive persisted. Hematologic and neurologic consultants were initially considered purely hematologic or neurologic diagnoses. Eventual consideration of unifying hypotheses led to definitive diagnosis 10 months after presentation. Hematologic abnormalities responded to copper supplementation, but neurologic abnormalities did not. The patient died of aspiration likely due to severe sensorimotor polyneuropathy. CONCLUSIONS: Early recognition of copper deficiency and improved warnings regarding excessive use of zinc-based denture adhesives may be the routes to improved outcomes.


Assuntos
Adesivos/efeitos adversos , Cobre/deficiência , Retenção de Dentadura/efeitos adversos , Compostos de Zinco/efeitos adversos , Evolução Fatal , Humanos , Masculino , Pessoa de Meia-Idade
10.
J Oral Rehabil ; 37(4): 256-61, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20050986

RESUMO

Although it is well known that conventional denture wearers have lower maximum bite forces than dentate subjects, no previous studies have compared the strength of the jaw muscles between these two groups. This study compared maximum bite forces, electromyographic (EMG) activity and estimated jaw muscle strength among three groups: (i) 17 edentulous subjects using newly acquired implant-retained overdentures (seven men, 10 women; mean age 60.3 +/- 13.0 years); (ii) 10 age-matched, fully dentate subjects (five men, five women; mean age 57.9 +/- 11.0 years); and (iii) 39 young, fully dentate subjects (19 men, 20 women; mean age 24.4 +/- 3.5 years). Electromyographic activity was recorded from subjects' bilateral superficial masseter and anterior temporalis muscles while they generated maximum voluntary bite forces at the right central incisor, right first premolar and right first molar positions. Jaw muscle strength was estimated as the ratio of average EMG activity for all four muscles to the maximum bite force. At all three bite positions, edentulous subjects produced maximum bite forces that were less than half that of dentate subjects. Edentulous subjects also produced significantly less EMG activity and had significantly lower estimated jaw muscle strength. Our results suggest that weakened jaw muscles are one factor contributing to lower maximum bite forces among users of conventional dentures.


Assuntos
Força de Mordida , Retenção de Dentadura/efeitos adversos , Revestimento de Dentadura/efeitos adversos , Músculos da Mastigação/fisiopatologia , Debilidade Muscular/etiologia , Adulto , Idoso , Estudos de Casos e Controles , Implantes Dentários , Prótese Dentária Fixada por Implante/efeitos adversos , Eletromiografia , Feminino , Humanos , Arcada Edêntula/fisiopatologia , Arcada Edêntula/reabilitação , Masculino , Mandíbula , Músculos da Mastigação/fisiologia , Análise por Pareamento , Pessoa de Meia-Idade , Força Muscular , Debilidade Muscular/fisiopatologia , Valores de Referência , Fatores de Tempo , Adulto Jovem
11.
Dent Traumatol ; 25(1): e3-4, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19208002

RESUMO

With the advent of predictable implant support and retention, the implant-supported overdenture (IOD) has become an accepted treatment modality, but some complications could be observed. We present a case report of squamous cell carcinoma developed in an edentulous ridge in relation to bar retaining IOD chronic trauma, in a patient with no history of previous oral cancer. To our knowledge, this is the first case described in the literature and suggests that primary malignancy can appear as a chronic traumatic ulcer and that a high degree of vigilance is required in the follow up of these patients.


Assuntos
Carcinoma de Células Escamosas/etiologia , Prótese Dentária Fixada por Implante/efeitos adversos , Retenção de Dentadura/efeitos adversos , Revestimento de Dentadura/efeitos adversos , Neoplasias Mandibulares/etiologia , Idoso , Retenção de Dentadura/instrumentação , Feminino , Humanos , Mandíbula , Úlceras Orais/etiologia
12.
J Prosthet Dent ; 99(1): 60-5, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18182187

RESUMO

STATEMENT OF PROBLEM: The oral mucosa has been reported to show a variety of changes in subjects with diabetes mellitus. PURPOSE: The purpose of this study was to compare diabetic and nondiabetic subjects wearing complete dentures with regard to salivary flow, salivary buffering capacity, denture retention, and oral mucosal lesions. MATERIAL AND METHODS: Sixty subjects, 30 with and 30 without a diagnosis of diabetes, were matched for gender, race, and age. Salivary flow, salivary buffering capacity, glycemia, blood pressure, presence of mucosal lesions, denture retention, use of medications, and behavioral factors (controlled or uncontrolled diet, alcohol consumption, and smoking) reported by the subjects, were evaluated. For the salivary buffering capacity test, 1 mL of saliva was pipetted into a test tube containing 3 mL 0.005 N of hydrochloric acid, and the pH was measured with indicator strips. Group differences were statistically analyzed using the Student t test and the Mann-Whitney test for quantitative variables and the chi-square test for qualitative variables (alpha =.05). RESULTS: Mean (SD) salivary flow was 1.14 (0.87) mL/min in the nondiabetic subjects and 0.95 (0.61) mL/min in the diabetic subjects. Evaluation of self-reported denture retention revealed no significant difference between groups. Denture retention was observed in 66.7% (20/30) of the control group and in 50% (15/30) of the diabetic group. The prevalence of mucosal lesions was 90% (27/30) in the control group and 83.3% (25/30) in the diabetic group. Salivary buffering capacity was 5.80 (0.85) in the control group and 5.26 (0.83) in the diabetic group (P=.017). CONCLUSIONS: Within the limitations of this study, no significant differences were observed in salivary flow, denture retention, or oral lesions in diabetic and nondiabetic subjects.


Assuntos
Retenção de Dentadura/efeitos adversos , Prótese Total/efeitos adversos , Diabetes Mellitus Tipo 2/complicações , Doenças da Boca/etiologia , Saliva/química , Salivação/fisiologia , Idoso , Idoso de 80 Anos ou mais , Soluções Tampão , Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus Tipo 2/tratamento farmacológico , Métodos Epidemiológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doenças da Boca/epidemiologia
13.
Quintessence Int ; 37(8): 659-62, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16922027

RESUMO

Suction cups, which provide high retention, are not being recommended anymore because of the destructive effect of the negative pressure on the palatal tissues. It is known that dentures with suction cups can cause perforations in the palate. In this case report, an oronasal communication caused by a denture with suction cup in a patient who had previously undergone pleomorphic adenoma excision of the palate is presented. Disadvantages of suction cups are emphasized.


Assuntos
Retenção de Dentadura/efeitos adversos , Doenças Nasais/etiologia , Fístula Bucal/etiologia , Palato/cirurgia , Fístula do Sistema Respiratório/etiologia , Adenoma Pleomorfo/cirurgia , Adulto , Retenção de Dentadura/instrumentação , Dentaduras/efeitos adversos , Humanos , Masculino , Doenças Nasais/terapia , Fístula Bucal/terapia , Fístula do Sistema Respiratório/terapia , Neoplasias das Glândulas Salivares/cirurgia , Sucção/efeitos adversos
16.
J Prosthet Dent ; 71(4): 350-8, 1994 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8195997

RESUMO

Ever since Bonwill recommended the use of rests on removable partial dentures in 1899, rests have been universally considered inviolate and have gone unchallenged and untested. The author claims that removable partial dentures without rests may not cause the adverse conditions usually predicted, such as gingival stripping, gingival inflammation, mutilated residual ridges, or extensive and rapid resorption of the alveolar ridges. In removable partial dentures made by the author for several patients, the residual ridge remained stable and in physiologic equilibrium when rests were not used. A history of the long-term effect on patients wearing partial dentures with and without rests is presented.


Assuntos
Planejamento de Dentadura , Retenção de Dentadura , Prótese Parcial Removível , Adulto , Idoso , Idoso de 80 Anos ou mais , Perda do Osso Alveolar/etiologia , Dente Suporte , Planejamento de Dentadura/efeitos adversos , Retenção de Dentadura/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Periodontite/diagnóstico , Periodontite/etiologia , Estudos Retrospectivos
20.
J Prosthet Dent ; 34(2): 164-9, 1975 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-1097655

RESUMO

(1) The replacement of a missing tooth or teeth by a fixed prosthesis as a preventive device is a paradox. (2) When a missing tooth is replaced by a fixed prosthesis, iatrogenic problems may occur. (3) The problems caused by the fabrication of a fixed partial denture must be recognized and controlled by both the patient and dentist. (4) Concerning the prognosis of any particular fixed prosthesis, we can only predict, from experience, the longevity of the replacement. The acutal life of the replacement is dependent upon the proficiency used in the maintenance procedures and the ability of the dentist to reduce or minimize the iatrogenic factors inherent in any fixed bridge.


Assuntos
Prótese Parcial Fixa/efeitos adversos , Cárie Dentária/etiologia , Cimentos Dentários/efeitos adversos , Retenção de Dentadura/efeitos adversos , Estética Dentária , Humanos , Doença Iatrogênica , Má Oclusão/prevenção & controle , Doenças Periodontais/etiologia , Migração de Dente/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...