Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 115
Filtrar
1.
Braz J Microbiol ; 54(4): 3321-3325, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37919460

RESUMO

In this prospective study, we aimed to investigate whether surgical gowns become contaminated during surgery. Samples from the gowns of five surgeons during 19 surgeries were collected using sterile swabs in circular standard delimited areas on both wrists and the mid-chest at three time-points: immediately before surgical incision (t=0), 30 min (t=30), and 60 min (t=60) later. Additionally, at t=0 and t=60, three settle plates of plate count agar were positioned at 1.5 m from the ground and remained open for 20 min. The operating room temperature and relative humidity were monitored. The swabs were cultivated and incubated, and colony-forming units per gram (CFU/g) counts were measured. The CFU/g counts for bacteria or fungi did not differ among the three sampling sites. The surgeons' lateral dominance in manual dexterity did not influence the gowns' contamination. There were significant variations in the temperature and relative humidity over time, but not in the CFU/g counts. In conclusion, during the first hour of surgery, surgical gowns did not become a source of contamination and are an effective barrier against bacterial and fungal contamination even under non-standard surgical environmental conditions.


Assuntos
Vestimenta Cirúrgica , Estudos Prospectivos , Roupa de Proteção/microbiologia , Salas Cirúrgicas , Bactérias
2.
J Vis Exp ; (194)2023 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-37092818

RESUMO

Lab coats are widely used in biohazard laboratories and healthcare facilities as protective garments to prevent direct exposure to pathogens, spills, and burns. These cotton-based protective coats provide ideal conditions for microbial growth and attachment sites due to their porous nature, moisture-holding capacity, and retention of warmth from the user's body. Several studies have demonstrated the survival of pathogenic bacteria on hospital garments and lab coats, acting as vectors of microbial transmission. A common approach to fix these problems is the application of antimicrobial agents in textile finishing, but concerns have been raised due to the toxicity and environmental effects of many synthetic chemicals. The ongoing pandemic has also opened a window for the investigation of effective antimicrobials and eco-friendly and toxic-free formulations. This study uses two natural bioactive compounds, carvacrol and thymol, encapsulated in chitosan nanoparticles, which guarantee effective protection against four human pathogens with up to a 4-log reduction (99.99%). These pathogens are frequently detected in lab coats used in biohazard laboratories. The treated fabrics also resisted up to 10 wash cycles with 90% microbial reduction, which is sufficient for the intended use. We made modifications to the existing standard fabric tests to better represent the typical scenarios of lab coat usage. These refinements allow for a more accurate evaluation of the effectiveness of antimicrobial lab coats and for the simulation of the fate of any accidental microbial spills that must be neutralized within a short time. Further studies are recommended to investigate the accumulation of pathogens over time on antimicrobial lab coats compared to regular protective coats.


Assuntos
Anti-Infecciosos , Cimenos , Desinfetantes , Nanocápsulas , Óleos Voláteis , Preparações de Plantas , Roupa de Proteção , Timol , Anti-Infecciosos/química , Anti-Infecciosos/farmacologia , Óleos Voláteis/química , Óleos Voláteis/farmacologia , Nanocápsulas/química , Preparações de Plantas/química , Preparações de Plantas/farmacologia , Roupa de Proteção/microbiologia , Laboratórios , Têxteis/microbiologia , Desinfetantes/química , Desinfetantes/farmacologia , Timol/química , Timol/farmacologia , Cimenos/química , Cimenos/farmacologia , Testes de Sensibilidade a Antimicrobianos por Disco-Difusão
3.
Orthopedics ; 44(3): e414-e416, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34039206

RESUMO

One method of preventing surgical-site infection is lowering intraoperative environmental contamination. The authors sought to evaluate their hospital's operating room (OR) contamination rate and compare it with the remainder of the hospital. They tested environmental contamination in preoperative, intraoperative, and postoperative settings for a total joint arthroplasty patient. A total of 190 air settle plates composed of trypsin soy agar were placed in 19 settings within the hospital. Locations included the OR with light and heavy traffic, with and without masks, jackets, and shoe covers; the substerile room; OR hallways; the sterile equipment processing center; preoperative areas; post-anesthesia care units; orthopedic floors; the emergency department; OR locker rooms and restrooms; a resident's home; and controls. The trypsin soy agar plates were incubated at 36 °C for 48 hours. Colony counts were performed for each plate. Average colony-forming units (CFUs) were calculated in each setting. The highest CFUs were in the OR locker room, at 28 CFUs per plate per hour. Preoperative and post-anesthesia care unit holding areas were 7.4 CFUs and 9.6 CFUs, respectively. The main orthopedic surgical ward had 10.0 CFUs per plate per hour, whereas the VIP hospital ward had 17.0 CFUs per plate per hour. All OR environments had low CFUs. A live OR had slightly higher CFUs than settings without OR personnel. In comparison with the local community household, the OR locker room, restrooms, hospital orthopedic wards, emergency department, preoperative holding, post-anesthesia care unit, and OR hallway all had higher airborne contamination. On the basis of these results, the authors recommend environmental sampling as a simple, fast, inexpensive tool for monitoring airborne contamination. [Orthopedics. 2021;44(3):e414-e416.].


Assuntos
Microbiologia do Ar , Hospitais , Salas Cirúrgicas , Infecção da Ferida Cirúrgica/prevenção & controle , Artroplastia de Substituição , Contagem de Colônia Microbiana , Serviço Hospitalar de Emergência , Humanos , Quartos de Pacientes , Roupa de Proteção/microbiologia , Equipamentos Cirúrgicos/microbiologia , Banheiros
4.
Health Phys ; 120(2): 123-130, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33369969

RESUMO

ABSTRACT: Healthcare-associated infections are a major public health concern for both patients and medical personnel. This has taken on greater urgency during the current COVID-19 pandemic. Radiation Personal Protective Equipment (RPPE) may contribute to risks of microbial contamination. This possibility was tested in 61 personal or shared-use lead aprons and thyroid collars at Columbia Presbyterian Irving Medical Center. Fifty percent tested positive for either bacterial or fungal contamination, mostly around the neckline of lead vests and thyroid collars. Repeated testing of garments some weeks to months later confirmed continued presence of microbial contamination. The possibility that hospital-approved disinfection agents could degrade the radio-protective features of these garments was also examined. Samples of identical construction to garments in regular use were subjected to either daily or weekly wipes with hypochlorite or alcohol-based hospital-approved cleaning agents for 6 mo. A third group of samples was maintained in contact with the cleaning agents for 6 mo. All samples were fluoroscoped four times during the study. None demonstrated any degradation in radioprotection. All samples were photographed monthly. Physical degradation of the outer plastic covering by concentrated hypochlorite and limited mechanical damage around stitched seams of the samples cleaned daily with alcohol was noted. Based on the high prevalence of microbial contamination, regular cleaning and disinfection protocols should be implemented. Regular cleaning with medical-facility-approved cleaning and disinfecting agents is likely to be effective at reducing the microbial load and unlikely to result in significant reduction in radioprotective properties of these garments.


Assuntos
Infecção Hospitalar/prevenção & controle , Desinfecção/métodos , Roupa de Proteção/microbiologia , Proteção Radiológica , Humanos , Equipamento de Proteção Individual , Risco
6.
J Small Anim Pract ; 61(5): 272-277, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32073144

RESUMO

OBJECTIVE: To determine contamination rates of scrub suits worn by veterinary surgeons and nurses following a single shift. MATERIALS AND METHODS: Cross-sectional preliminary study at a UK small animal referral centre. Sterilised scrub suits were distributed to veterinary surgeons (n = 9) and nurses (n = 9) at the beginning of their clinical shift and worn for at least 8 hours. They were then analysed for bacterial contamination before and after home laundry at 30°C. A questionnaire was distributed to hospital clinical staff regarding workwear habits. RESULTS: Median bacterial counts were 47 (interquartile range: 14 to 162) and 7 (interquartile range: 0 to 27) colony forming units per cm2 before and after laundering scrub suits. Bacteria identified included Staphylococcus sp., Enterococcus sp., Escherichia coli , Bacillus sp., Pseudomonas aeruginosa , Micrococcus sp., ß-haemolytic Streptococci and a Group G Streptococcus. From 101 staff surveyed, 64.0% reported wearing fresh, clean scrub tops and 58.4% fresh, clean trousers each day, while 64.4% left the workplace wearing the same clothing in which they undertook clinical work. CLINICAL SIGNIFICANCE: Workwear contamination risks spread of pathogens into the community and personnel compliance with workplace guidelines warrants further attention. Home laundry at 30°C significantly decreases, but does not eliminate, the bacterial burden after a single shift.


Assuntos
Contaminação de Equipamentos , Roupa de Proteção , Animais , Carga Bacteriana/veterinária , Estudos Transversais , Hábitos , Humanos , Roupa de Proteção/microbiologia , Encaminhamento e Consulta
7.
Ann Clin Microbiol Antimicrob ; 18(1): 37, 2019 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-31779615

RESUMO

This study aimed at detecting Staphylococcus aureus from white coats of college students and characterizing antimicrobial susceptibility and biofilm production. Bacterial samples (n = 300) were obtained from white coats of 100 college students from August 2015 to March 2017 S. aureus was isolated and it´s resistance profile was assessed by antimicrobial disk-diffusion technique, screening for methicillin-resistant Staphylococcus aureus (MRSA), detection of mecA gene by PCR, and determination of staphylococcal cassette chromosome mec (SCCmec) by multiplex PCR. Congo red agar (CRA) and icaA and icaD genes by PCR were used for biofilm characterization. S. aureus was identified in 45.0% of samples. Resistance of S. aureus sample to antimicrobial was seen for penicillin (72.59%), erythromycin (51.85%), cefoxitin (20.74%), oxacillin (17.04%), clindamycin (14.81%) and levofloxacin (5.18%). MRSA was detected in 53.3% of the samples with SCCmec I (52.8%), SCCmec III (25%) and SCCmec IV (11.1%). Biofilm production was observed in 94.0% S. aureus samples. These data show that biosafety measures need to be enhanced in order to prevent dissemination of multiresistant and highly adhesive bacteria across other university settings, relatives, and close persons.


Assuntos
Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Roupa de Proteção/microbiologia , Staphylococcus aureus/isolamento & purificação , Antibacterianos , Proteínas de Bactérias/genética , Biofilmes/crescimento & desenvolvimento , Contenção de Riscos Biológicos , Genes Bacterianos , Humanos , Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos , Staphylococcus aureus Resistente à Meticilina/genética , Testes de Sensibilidade Microbiana , Proteínas de Ligação às Penicilinas/genética , Staphylococcus aureus/efeitos dos fármacos , Staphylococcus aureus/genética , Estudantes , Universidades
8.
Clin Infect Dis ; 69(Suppl 3): S171-S177, 2019 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-31517979

RESUMO

BACKGROUND: Healthcare personnel (HCP) acquire antibiotic-resistant bacteria on their gloves and gowns when caring for intensive care unit (ICU) patients. Yet, contact precautions for patients with methicillin-resistant Staphylococcus aureus (MRSA) remains controversial despite existing guidelines. We sought to understand which patients are more likely to transfer MRSA to HCP and to identify which HCP interactions are more likely to lead to glove or gown contamination. METHODS: This was a prospective, multicenter cohort study of cultured HCP gloves and gowns for MRSA. Samples were obtained from patients' anterior nares, perianal area, and skin of the chest and arm to assess bacterial burden. RESULTS: Among 402 MRSA-colonized patients with 3982 interactions, we found that HCP gloves and gowns were contaminated with MRSA 14.3% and 5.9% of the time, respectively. Contamination of either gloves or gowns occurred in 16.2% of interactions. Contamination was highest among occupational/physical therapists (odds ratio [OR], 6.96; 95% confidence interval [CI], 3.51, 13.79), respiratory therapists (OR, 5.34; 95% CI, 3.04, 9.39), and when any HCP touched the patient (OR, 2.59; 95% CI, 1.04, 6.51). Touching the endotracheal tube (OR, 1.75; 95% CI, 1.38, 2.19), bedding (OR, 1.43; 95% CI, 1.20, 1.70), and bathing (OR, 1.32; 95% CI, 1.01, 1.75) increased the odds of contamination. We found an association between increasing bacterial burden on the patient and HCP glove or gown contamination. CONCLUSIONS: Gloves and gowns are frequently contaminated with MRSA in the ICU. Hospitals may consider using fewer precautions for low-risk interactions and more for high-risk interactions and personnel.


Assuntos
Infecção Hospitalar/prevenção & controle , Farmacorresistência Bacteriana Múltipla , Pessoal de Saúde/educação , Controle de Infecções/métodos , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Infecções Estafilocócicas/transmissão , Canal Anal/microbiologia , Carga Bacteriana/estatística & dados numéricos , Infecção Hospitalar/microbiologia , Contaminação de Equipamentos/prevenção & controle , Luvas Protetoras/microbiologia , Humanos , Controle de Infecções/instrumentação , Unidades de Terapia Intensiva , Staphylococcus aureus Resistente à Meticilina , Nariz/microbiologia , Pacientes , Estudos Prospectivos , Roupa de Proteção/microbiologia , Pele/microbiologia , Infecções Estafilocócicas/prevenção & controle
9.
Am J Infect Control ; 47(8): 994-1001, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30850250

RESUMO

BACKGROUND: Horizontal transmission of bacteria, especially multidrug-resistant organisms (MDROs), remains an important concern in hospitals worldwide. Some studies have implicated provider attire in the transmission of organisms within hospitals, whereas others have suggested that evidence supporting this notion is limited. METHODS: PubMed was searched for publications between 1990 and 2018 to identify studies of bacterial contamination of, or dissemination of, bacteria from physician, nursing, or trainee attire, with a specific focus on white coats and surgical scrubs. A total of 214 articles were identified. Of these, 169 were excluded after abstract review and 33 were excluded after in-depth full manuscript review. RESULTS: Twenty-two articles were included: 16 (73%) cross-sectional studies, 4 (18%) randomized controlled trials, and 2 (9%) cohort studies. Results are organized by microbial contaminants, antibiotic resistance, types of providers, fabric type, antimicrobial coating, and laundering practices. Provider attire was commonly colonized by MDROs, with white coats laundered less frequently than scrubs. Studies revealed considerable differences among fabrics used and laundering practices. CONCLUSIONS: Findings suggest that provider attire is a potential source of pathogenic bacterial transmission in health care settings. However, data confirming a direct link between provider attire and health care-associated infections remain limited. Suggestions outlined in this article may serve as a guideline to reduce the spread of bacterial pathogens, including MDROs, that have the potential to precipitate hospital-acquired infections.


Assuntos
Ocupações em Saúde , Roupa de Proteção/microbiologia , Estudos Transversais , Humanos , Lavanderia
11.
Infect Control Hosp Epidemiol ; 40(4): 460-462, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30767838

RESUMO

We demonstrated that hand washing resulted in frequent dispersal of gram-negative bacilli from colonized sink drains in hospitals to cover gowns and hands. A plastic drain cover reduced but did not eliminate the risk for contamination. This mechanism of dispersal could result in contamination of healthcare personnel and patients.


Assuntos
Infecção Hospitalar/microbiologia , Bactérias Gram-Negativas/isolamento & purificação , Mãos/microbiologia , Roupa de Proteção/microbiologia , Contaminação de Equipamentos , Desinfecção das Mãos/métodos , Pessoal de Saúde , Hospitais , Humanos
12.
Clin Nurs Res ; 28(1): 94-106, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-28627936

RESUMO

The objective of this study was to identify the types of microorganisms present on uniforms of nurses, physicians, respiratory therapist, students, and housekeepers in intensive care units (ICUs). A convenience sampling was used to recruit the participants ( N = 115) who work at military hospital in Jordan. Environmental cultures ( N = 305) were taken from the participants who were nurses, physicians, students, respiratory therapists, and housekeepers. The number of participating nurses was 58 (50.43%). There were 24 types of microorganisms found on the participants' uniforms. Staphylococcus epidermidis was found 59 times (61.3%) on the three areas of uniform culture. High level of contamination was found among all the participants, and it was the highest in physicians (85%) followed by nurse (79.3%) (χ2 = 24.87, p < .001). None of the participants' characteristics have correlated significantly with the uniform contamination. High percentages of uniform's contamination among all those who work in the ICUs were found.


Assuntos
Infecção Hospitalar , Pessoal de Saúde/estatística & dados numéricos , Unidades de Terapia Intensiva/normas , Roupa de Proteção , Infecções Estafilocócicas/transmissão , Adulto , Infecção Hospitalar/microbiologia , Infecção Hospitalar/prevenção & controle , Feminino , Hospitais Militares , Humanos , Controle de Infecções/normas , Jordânia , Masculino , Roupa de Proteção/microbiologia , Roupa de Proteção/normas , Inquéritos e Questionários
13.
Am J Epidemiol ; 188(1): 214-221, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-30351349

RESUMO

The prevalence of methicillin-resistant Staphylococcus aureus (MRSA) colonization among nursing home residents is high. Health-care workers (HCWs) often serve as a vector in MRSA transmission. The ability to identify residents who are likely to transmit MRSA to HCWs' hands and clothing during clinical care is important so that infection control measures, such as Contact Precautions, can be employed. Using data on demographic and clinical characteristics collected from residents of community nursing homes in Maryland and Michigan between 2012 and 2014, we developed a clinical prediction rule predicting the probability of MRSA transmission to HCWs' gowns. We externally validated this model in a cohort of Department of Veterans Affairs nursing home residents from 7 states between 2012 and 2016. The prediction model, which included sex, race, resident dependency on HCWs for care, the presence of any medical device, diabetes mellitus, and chronic skin breakdown, showed good performance (C statistic = 0.70; sensitivity = 76%, specificity = 49%) in the development set. The decision curve analysis indicated that this model has greater clinical utility than use of a nares surveillance culture for MRSA colonization, which is current clinical practice for placing hospital inpatients on Contact Precautions. The prediction rule demonstrated less utility in the validation cohort, suggesting that a separate rule should be developed for residents of Veterans Affairs nursing homes.


Assuntos
Infecção Hospitalar/transmissão , Técnicas de Apoio para a Decisão , Instituição de Longa Permanência para Idosos/estatística & dados numéricos , Staphylococcus aureus Resistente à Meticilina , Casas de Saúde/estatística & dados numéricos , Infecções Estafilocócicas/transmissão , Idoso , Idoso de 80 Anos ou mais , Comorbidade , Infecção Hospitalar/epidemiologia , Feminino , Pessoal de Saúde , Humanos , Masculino , Maryland , Michigan , Pessoa de Meia-Idade , Probabilidade , Roupa de Proteção/microbiologia , Fatores Raciais , Fatores Sexuais , Fatores Socioeconômicos , Infecções Estafilocócicas/epidemiologia , Estados Unidos , United States Department of Veterans Affairs
14.
Infect Control Hosp Epidemiol ; 39(12): 1425-1430, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30293533

RESUMO

OBJECTIVE: To estimate the risk of transmission of antibiotic-resistant Gram-negative bacteria (RGNB) to gowns and gloves worn by healthcare personnel (HCP) when providing care to residents of community-based nursing facilities to identify the types of care and resident characteristics associated with transmission. DESIGN: Prospective observational study.Settings and participantsResidents and HCP from 13 community-based nursing facilities in Maryland and Michigan. METHODS: Perianal swabs were collected from residents and cultured to detect RGNB. HCP wore gowns and gloves during usual care activities, and at the end of each interaction, these were swabbed in a standardized manner. Transmission of RGNB from a colonized resident to gowns and gloves was estimated. Odds ratios (ORs) of transmission associated with type of care or resident characteristic were calculated. RESULTS: We enrolled 403 residents and their HCP in this study. Overall, 19% of enrolled residents with a perianal swab (n=399) were colonized with at least 1 RGNB. RGNB transmission to either gloves or gowns occurred during 11% of the 584 interactions. Showering the resident, hygiene or toilet assistance, and wound dressing changes were associated with a high risk of transmission. Glucose monitoring and assistance with feeding or medication were associated with a low risk of transmission. Residents with a pressure ulcer were 3 times more likely to transmit RGNB than residents without one (OR, 3.3; 95% confidence interval [CI], 1.0-11.1). CONCLUSIONS: Gown and glove use in community nursing facilities should be prioritized for certain residents and care interactions that are deemed a high risk for transmission.


Assuntos
Infecção Hospitalar/transmissão , Luvas Protetoras/microbiologia , Bactérias Gram-Negativas/isolamento & purificação , Infecções por Bactérias Gram-Negativas/transmissão , Casas de Saúde , Roupa de Proteção/microbiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Infecção Hospitalar/microbiologia , Farmacorresistência Bacteriana Múltipla , Feminino , Bactérias Gram-Negativas/crescimento & desenvolvimento , Pessoal de Saúde , Humanos , Modelos Logísticos , Masculino , Maryland , Michigan , Pessoa de Meia-Idade , Estudos Prospectivos
15.
J Invasive Cardiol ; 30(11): 416-420, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30373951

RESUMO

OBJECTIVES: Quantify and characterize bacterial contamination of lead aprons in a high-volume catheterization laboratory and evaluate the efficacy of decontamination using an ultraviolet-C (UV-C) radiation system. BACKGROUND: Bacterial contamination and ineffective disinfection of personal protective equipment in medical centers pose potential health risks to patients and medical staff. The contamination burden of lead aprons and a reliable disinfection strategy are unknown. METHODS: Ten routinely used, unsterilized lead aprons from a high-volume catheterization laboratory were studied. Standard and bacteria-resistant outer fabrics were included. Swabbings from four locations on each apron (inner thyroid collar, chest, waist, and bottom border) were obtained at baseline and after a 15-minute decontamination cycle using the UV-C based DCab System (Nosocom Solutions). Colony counts, speciation, and antibiotic resistance were obtained from aerobic and anaerobic cultures. RESULTS: Baseline cultures grew ≥1 colony from 25 of 40 samples (62.5%; 310 colonies; 0-100 colonies/sample; 16 organisms), mainly skin and mouth flora without antibiotic resistance. Baseline growth was greatest from the thyroid collar and similar between different fabrics. UV-C reduced subsequent growth (7.8 ± 23.8 colonies overall vs 0.1 ± 0.3 colonies overall; P<.001), with all four isolates considered contaminants of laboratory handling. Colony counts were reduced in thyroid collar, chest, waist, nylon fabric, polyurethane fabric, and alternative bacteria-resistant fabric subgroups (all P<.05). CONCLUSIONS: Routinely used lead aprons in a high-volume catheterization laboratory were contaminated by non-pathogenic skin and mouth flora located predominantly on the thyroid collar. Disinfection using an automated UV-C based system is highly effective across different apron surface locations and fabric types.


Assuntos
Infecções Bacterianas/prevenção & controle , Infecção Hospitalar/prevenção & controle , Desinfecção/métodos , Contaminação de Equipamentos/prevenção & controle , Roupa de Proteção/microbiologia , Proteção Radiológica/instrumentação , Raios Ultravioleta , Bactérias/isolamento & purificação , Infecções Bacterianas/microbiologia , Cateterismo Cardíaco , Contagem de Colônia Microbiana , Humanos
16.
Infect Control Hosp Epidemiol ; 39(11): 1316-1321, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30156175

RESUMO

OBJECTIVE: To compare bacterial contamination of military-approved uniforms and hospital-provided scrubs donned by nursing staff in an inpatient setting. DESIGN: Randomized experimental crossover study. SETTING: Large academic military medical center. METHODS: Inpatient units were randomized to predetermine the order of uniform sampling. Participants included nursing staff who provided direct patient care across 7 eligible inpatient units. Sampling of 6 designated sites on the uniform was completed on arrival to work, at ~4 hours into their shift, and at the 8-hour time point, for a total of 18 samples. Sampling of each participant occurred on 2 separate occasions, once in a military-approved uniform, and once in hospital-provided scrubs. After 24 hours of incubation, a colony-counting machine was used to calculate the total colony-forming units (CFU) of the sample. RESULTS: Across all time points, military-approved uniforms demonstrated a 2-fold bacterial increase at the abdominal site and 3-fold increases at the sleeve cuff and waist pocket regions compared to the same regions on hospital-provided scrubs. CONCLUSION: Nurses should be aware that bacteria are present at much higher levels on their personal military uniforms compared to hospital-provided scrubs. Additional research is needed to determine whether these findings are a function of wear, laundering, or environmental factors. Nurses should adhere to daily uniform washing to reduce bacterial load and minimize risk of nosocomial infections to the patients they care for.


Assuntos
Infecção Hospitalar/microbiologia , Contaminação de Equipamentos/estatística & dados numéricos , Hospitais Militares , Recursos Humanos de Enfermagem Hospitalar , Roupa de Proteção/microbiologia , Adulto , Carga Bacteriana/métodos , Contagem de Colônia Microbiana/métodos , Estudos Cross-Over , Feminino , Humanos , Controle de Infecções , Masculino , Militares , Assistência ao Paciente , Adulto Jovem
17.
Infect Control Hosp Epidemiol ; 39(9): 1063-1067, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30051793

RESUMO

OBJECTIVE: To determine which healthcare worker (HCW) roles and patient care activities are associated with acquisition of vancomycin-resistant Enterococcus (VRE) on HCW gloves or gowns after patient care, as a surrogate for transmission to other patients. DESIGN: Prospective cohort study. SETTING: Medical and surgical intensive care units at a tertiary-care academic institution.ParticipantsVRE-colonized patients on Contact Precautions and their HCWs. METHODS: Overall, 94 VRE-colonized patients and 469 HCW-patient interactions were observed. Research staff recorded patient care activities and cultured HCW gloves and gowns for VRE before doffing and exiting patient room. RESULTS: VRE were isolated from 71 of 469 HCWs' gloves or gowns (15%) following patient care. Occupational/physical therapists, patient care technicians, nurses, and physicians were more likely than environmental services workers and other HCWs to have contaminated gloves or gowns. Compared to touching the environment alone, the odds ratio (OR) for VRE contamination associated with touching both the patient (or objects in the immediate vicinity of the patient) and environment was 2.78 (95% confidence interval [CI], 0.99-0.77) and the OR associated with touching only the patient (or objects in the immediate vicinity) was 3.65 (95% CI, 1.17-11.41). Independent risk factors for transmission of VRE to HCWs were touching the patient's skin (OR, 2.18; 95% CI, 1.15-4.13) and transferring the patient into or out of bed (OR, 2.66; 95% CI, 1.15-6.43). CONCLUSION: Patient contact is a major risk factor for HCW contamination and subsequent transmission. Interventions should prioritize contact precautions and hand hygiene for HCWs whose activities involve touching the patient.


Assuntos
Infecção Hospitalar/transmissão , Luvas Protetoras/microbiologia , Infecções por Bactérias Gram-Positivas/transmissão , Roupa de Proteção/microbiologia , Enterococos Resistentes à Vancomicina/isolamento & purificação , Idoso , Contaminação de Equipamentos , Feminino , Pessoal de Saúde/estatística & dados numéricos , Humanos , Transmissão de Doença Infecciosa do Profissional para o Paciente/prevenção & controle , Unidades de Terapia Intensiva , Modelos Logísticos , Masculino , Maryland , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Resistência a Vancomicina
18.
Infect Control Hosp Epidemiol ; 39(9): 1093-1107, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30039774

RESUMO

OBJECTIVE: The transfer of pathogens may spread antimicrobial resistance and lead to healthcare-acquired infections. We performed a systematic literature review to generate estimates of pathogen transfer in relation to healthcare provider (HCP) activities. METHODS: For this systematic review and meta-analysis, Medline/Ovid, EMBASE, and the Cochrane Library were searched for studies published before July 7, 2017. We reviewed the literature, examining transfer of pathogens associated with HCP activities. We included studies that (1) quantified transfer of pathogens from a defined origin to a defined destination surface; (2) reported a microbiological sampling technique; and (3) described the associated activity leading to transfer. For studies reporting transfer frequencies, we extracted data and calculated the estimated proportion using Freeman-Tukey double arcsine transformation and the DerSimonian-Laird random-effects model. RESULTS: Of 13,121 identified articles, 32 were included. Most articles (n=27, 84%) examined transfer from patients and their environment to HCP hands, gloves, and gowns, with an estimated proportion for transfer frequency of 33% (95% confidence interval [CI], 12%-57%), 30% (95% CI, 23%-38%) and 10% (95% CI, 6%-14%), respectively. Other articles addressed transfer involving the hospital environment and medical devices. Risk factor analyses in 12 studies suggested higher transfer frequencies after contact with moist body sites (n=7), longer duration of care (n=5), and care of patients with an invasive device (n=3). CONCLUSIONS: Recognizing the heterogeneity in study designs, the available evidence suggests that pathogen transfer to HCPs occurs frequently. More systematic research is urgently warranted to support targeted and economic prevention policies and interventions.


Assuntos
Infecção Hospitalar/transmissão , Transmissão de Doença Infecciosa do Paciente para o Profissional/estatística & dados numéricos , Transmissão de Doença Infecciosa do Profissional para o Paciente/estatística & dados numéricos , Contaminação de Equipamentos , Equipamentos e Provisões/microbiologia , Luvas Protetoras/microbiologia , Mãos/microbiologia , Humanos , Roupa de Proteção/microbiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...