Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Mikrochim Acta ; 188(3): 73, 2021 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-33550423

RESUMO

Gelatin microsphere-coated Fe3O4@graphene quantum dots (Fe3O4@GQD@GM) were designed and synthesized as a novel sorbent via ultrasonic-assisted dispersive magnetic solid-phase extraction (UA-DMSPE) method. The synthesized sorbent was identified and confirmed by FT-IR, XRD, VSM, and SEM techniques. UA-DMSPE was combined with corona discharge ion mobility spectrometry for trace determination of desipramine, sertraline, and citalopram. Effective parameters were considered and optimized. The proposed method, under optimal conditions, showed excellent linearity in different concentration ranges (2-700 ng mL-1, R2 > 0.995), repeatability (RSD < 5.1%), good sensitivity (LODs in the range 0.6-1.5 ng mL-1), high preconcentration factor (PF = 207-218), and acceptable relative recoveries (93.5-101.8%). Eventually, this method was used to determine tricyclic antidepressants in various biological samples. Schematic presentation of the microextraction and monitoring of TCAs by ultrasonic-assisted dispersive magnetic solid phase microextraction-ion mobility spectrometry producer.


Assuntos
Antidepressivos Tricíclicos/isolamento & purificação , Microesferas , Nanocompostos/química , Pontos Quânticos/química , Extração em Fase Sólida/métodos , Adsorção , Antidepressivos Tricíclicos/sangue , Antidepressivos Tricíclicos/química , Antidepressivos Tricíclicos/urina , Citalopram/sangue , Citalopram/química , Citalopram/isolamento & purificação , Citalopram/urina , Desipramina/sangue , Desipramina/química , Desipramina/isolamento & purificação , Desipramina/urina , Gelatina/química , Grafite/química , Humanos , Limite de Detecção , Fenômenos Magnéticos , Nanopartículas de Magnetita/química , Sertralina/sangue , Sertralina/química , Sertralina/isolamento & purificação , Sertralina/urina
2.
J Sep Sci ; 44(6): 1195-1202, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33137222

RESUMO

The synthesis and application of glutathione-coated magnetic nanocomposite were introduced with the purpose of developing a stable, cheap, operationally convenient, simple, fast, sensitive, and selective device for the microextraction of diazepam and sertraline for the first time. The prepared glutathione@Fe3 O4 nanocomposite was used as the sorbent in the form of magnetic solid-phase extraction. Afterward, the extracted analytes were desorbed by organic solvent and analyzed by high-performance liquid chromatography-ultraviolet detection. Several influential variables such as desorption time, desorption volume, sample pH, extraction time, and sorbent amount were screened through Plackett-Burman design and then optimized via Box-Behnken design. The obtained results showed that the above-mentioned method enjoys a good linear range (0.2-500 µg/L) with the coefficient of determination higher than 0.9927, low limits of determination (0.07-0.24 µg/L), acceptable limits of quantification (0.22-0.93 µg/L), good enrichment factors (128 and 153), and good spiking recoveries (95-105%) for diazepam and sertraline under the obtained optimized condition. Analyzing the real samples results in the confirmation of the presented method and it can be applied for the analysis of various organic compounds in biological samples.


Assuntos
Diazepam/isolamento & purificação , Glutationa/química , Nanopartículas de Magnetita/química , Sertralina/isolamento & purificação , Extração em Fase Sólida , Adsorção , Cromatografia Líquida de Alta Pressão , Diazepam/química , Diazepam/urina , Feminino , Voluntários Saudáveis , Humanos , Fenômenos Magnéticos , Masculino , Tamanho da Partícula , Sertralina/química , Sertralina/urina , Propriedades de Superfície
3.
Fertil Steril ; 114(6): 1278-1287, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33066974

RESUMO

OBJECTIVE: To prospectively investigate the association of selective serotonin reuptake inhibitor (SSRI) exposure through critical windows of pregnancy establishment with fecundability and pregnancy loss. DESIGN: Prospective cohort study using longitudinal urine measurements of common SSRIs while women are actively trying to conceive. SETTING: Four clinical sites. PATIENT(S): A total of 1,228 women without uncontrolled depression/anxiety, attempting natural conception while participating in a randomized trial of preconception-initiated low-dose aspirin. INTERVENTIONS(S): Not applicable. MAIN OUTCOME MEASURE(S): Urinary SSRIs (fluoxetine, sertraline, escitalopram/citalopram) were measured while trying to conceive and, for women who became pregnant, at weeks 0, 4, and 8 of pregnancy. Fecundability odds ratios and incidence of pregnancy loss and live birth were estimated. RESULT(S): A total of 172 women (14%) were exposed to SSRIs while trying to conceive. SSRI exposure was associated with 24% reduced fecundability, and accordingly, a nonsignificant 9% lower live birth incidence, with significantly lower live birth in fluoxetine-exposed women. SSRI exposure was not associated with subsequent pregnancy loss, whether exposure was before conception or at 0, 4, or 8 weeks of gestation, although estimates varied by specific SSRI drug. CONCLUSION(S): Women using SSRIs may have more difficulty becoming pregnant, and although SSRI exposure overall was not associated with pregnancy loss, fluoxetine deserves caution and future study. CLINICAL TRIAL REGISTRATION NUMBER: NCT00467363.


Assuntos
Aborto Espontâneo/induzido quimicamente , Fertilidade/efeitos dos fármacos , Inibidores Seletivos de Recaptação de Serotonina/efeitos adversos , Inibidores Seletivos de Recaptação de Serotonina/urina , Aborto Espontâneo/diagnóstico , Aborto Espontâneo/urina , Adulto , Citalopram/urina , Feminino , Fluoxetina/efeitos adversos , Fluoxetina/urina , Humanos , Nascido Vivo , Gravidez , Primeiro Trimestre da Gravidez/urina , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Fatores de Risco , Sertralina/efeitos adversos , Sertralina/urina , Fatores de Tempo , Estados Unidos , Adulto Jovem
4.
Artigo em Inglês | MEDLINE | ID: mdl-32213465

RESUMO

In this study, the use of switchable hydrophilicity solvent with a simple and low-cost lab-made device for the extraction procedure in homogeneous liquid-liquid microextraction is proposed for the first time in the determination of antidepressants in human urine. The antidepressants studied consisted of fluoxetine, amitriptyline, nortriptyline, imipramine, desipramine and sertraline. The optimization of the main parameters that can influence on the extraction efficiency was performed through multivariate approaches. The analytes were separated and identified by gas chromatography coupled to mass spectrometry (GC-MS). The optimal extraction conditions consisted of using N,N-dimethylcyclohexylamine (DMCHA) as the switchable hydrophilicity solvent (SHS), 500 µL of urine sample previously diluted with ultrapure water at 1:1 ratio (v/v), 200 µL of a mixture of SHS:HCl 6 mol L-1 (1:1 v/v), 600 µL of NaOH 10 mol L-1 and 3 min of extraction time. A volume of 40 µL of diphenylamine at concentration of 500 µg L-1 (20 ng) was used as internal standard. The method developed was in-house validated, providing coefficients of determination higher than 0.995 for all analytes, limits of detection (LOD) from 0.02 to 0.88 µg L-1, limits of quantification (LOQ) from 0.05 to 2.92 µg L-1, relative recoveries of 68 to 102%, intra-day precision from 0.5 to 15.9%, inter-day precision from 4.2 to 19.3%, selectivity and robustness. The method proposed was successfully applied in five human urine samples from a Toxicological Information Center located in Porto Alegre (Brazil). The results demonstrated that the µP-SHS-HLLME approach is highly cost-effective, rapid, simple and environmentally-friendly with satisfactory analytical performance.


Assuntos
Antidepressivos/urina , Adulto , Amitriptilina/urina , Cicloexilaminas/química , Desipramina/urina , Fluoxetina/urina , Cromatografia Gasosa-Espectrometria de Massas , Química Verde , Humanos , Interações Hidrofóbicas e Hidrofílicas , Imipramina/urina , Limite de Detecção , Microextração em Fase Líquida , Nortriptilina/urina , Sertralina/urina , Solventes/química
5.
Bioanalysis ; 12(1): 35-52, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31849264

RESUMO

Aim: Routine therapeutic drug monitoring is highly recommended since common antidepressant combinations increase the risk of drug-drug interactions or overlapping toxicity. Materials & methods: A magnetic solid-phase extraction by using C18-functionalized magnetic silica nanoparticles (C18-Fe3O4@SiO2 NPs) as sorbent was proposed for rapid extraction of venlafaxine, paroxetine, fluoxetine, norfluoxetine and sertraline from clinical plasma and urine samples followed by ultra-HPLC-MS/MS assay. Results: The synthesized C18-Fe3O4@SiO2 NPs showed high magnetization and efficient extraction for the analytes. After cleanup by magnetic solid-phase extraction, no matrix effects were found in plasma and urine matrices. The analytes showed LODs among 0.15-0.75 ng ml-1, appropriate linearity (R ≥ 0.9990) from 2.5 to 1000 ng ml-1, acceptable accuracies 89.1-110.9% with precisions ≤11.0%. The protocol was successfully applied for the analysis of patients' plasma and urine samples. Conclusion: It shows high potential in routine therapeutic drug monitoring of clinical biological samples.


Assuntos
Antidepressivos/análise , Nanopartículas de Magnetita/química , Antidepressivos/isolamento & purificação , Antidepressivos/metabolismo , Cromatografia Líquida de Alta Pressão , Fluoxetina/análogos & derivados , Fluoxetina/sangue , Fluoxetina/isolamento & purificação , Fluoxetina/urina , Humanos , Concentração de Íons de Hidrogênio , Limite de Detecção , Paroxetina/sangue , Paroxetina/isolamento & purificação , Paroxetina/urina , Reprodutibilidade dos Testes , Sertralina/sangue , Sertralina/isolamento & purificação , Sertralina/urina , Dióxido de Silício/química , Extração em Fase Sólida , Solventes/química , Espectrometria de Massas em Tandem , Cloridrato de Venlafaxina/sangue , Cloridrato de Venlafaxina/isolamento & purificação , Cloridrato de Venlafaxina/urina
6.
Clin Chim Acta ; 499: 81-86, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31491368

RESUMO

BACKGROUND: Many clinical toxicology laboratories receive urine specimens in urine cups that contain point of care (POC) drug testing strips. We conducted this study to evaluate the effect on the stability of commonly measured drugs in the clinical toxicology laboratory when urine is exposed to POC urine drug testing cups. METHODS: Drug free urine was spiked with 85 drugs that were measured by a validated liquid chromatography mass spectrometry (LCMS) method after exposure to POC urine drug testing cups at ambient and 2-6 °C temperatures. Alterations ≥20% were defined as significant changes in the drugs concentration. RESULTS: Concentrations of amitriptyline, cyclobenzaprine, fentanyl, fluoxetine, flunitrazepam, nortriptyline, paroxetine, and sertraline were significantly reduced when urine specimens were stored inside POC urine drug testing cups for 24 h at ambient temperature. Storage of urine in urine chemistry dipsticks reduced the concentration of several drugs. When spiked urine was exposed to an increasing number of POC urine drug testing strips, the concentrations of some drugs were reduced in a dose-dependent manner. The drugs that were absorbed by POC urine drug testing strips were partially back extracted from the strips. CONCLUSION: Exposure of urine specimens to POC urine drug testing strips reduces the concentration of several drugs measured by LCMS method.


Assuntos
Testes Imediatos , Amitriptilina/análogos & derivados , Amitriptilina/urina , Cromatografia Líquida , Armazenamento de Medicamentos , Fentanila/urina , Flunitrazepam/urina , Fluoxetina/urina , Humanos , Espectrometria de Massas , Nortriptilina/urina , Paroxetina/urina , Sertralina/urina
8.
Talanta ; 101: 460-4, 2012 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-23158349

RESUMO

A novel method for the determination of sertraline using dispersive liquid-liquid microextraction (DLLME) coupled with capillary electrophoresis (CE) was developed. Acetone and dichloromethane were used as the disperser solvent and extraction solvent, respectively. A mixture of the extraction and disperser solvents was rapidly injected into a 1.0 mL aqueous sample to form a cloudy solution. After the extraction, sertraline was analyzed using CE that was equipped with UV detection. A 74-fold improvement in the sensitivity was observed when DLLME was used to extract sertraline. Since the DLLME extract residue was redissolved with 5 µL of water that contained 20% methanol, the detection sensitivity was further enhanced through the use of field-amplified sample stacking (FASS). A 11-fold improvement in the sensitivity was obtained when FASS was used to on-line concentrate sertraline. Under optimal extraction and stacking conditions, the calibration curve, which ranged from 0.01 to 1 µM was observed to be linear. The limit of detection (LOD) at a signal-to-noise ratio of 3 was 2.5 nM for sertraline. An approximately 814-fold improvement in the sensitivity was observed for sertraline compare with injection of standard solution without the DLLME and FASS procedures. This developed method was successfully applied to the determination of sertraline in human urine samples.


Assuntos
Eletroforese Capilar/métodos , Inibidores Seletivos de Recaptação de Serotonina/análise , Sertralina/análise , Humanos , Limite de Detecção , Microextração em Fase Líquida , Inibidores Seletivos de Recaptação de Serotonina/urina , Sertralina/urina
10.
Anal Bioanal Chem ; 382(6): 1351-9, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15986209

RESUMO

In this paper a solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) method is proposed for a rapid analysis of some frequently prescribed selective serotonin re-uptake inhibitors (SSRI)-venlafaxine, fluvoxamine, mirtazapine, fluoxetine, citalopram, and sertraline-in urine samples. The SPME-based method enables simultaneous determination of the target SSRI after simple in-situ derivatization of some of the target compounds. Calibration curves in water and in urine were validated and statistically compared. This revealed the absence of matrix effect and, in consequence, the possibility of quantifying SSRI in urine samples by external water calibration. Intra-day and inter-day precision was satisfactory for all the target compounds (relative standard deviation, RSD, <14%) and the detection limits achieved were <0.4 ng mL(-1) urine. The time required for the SPME step and for GC analysis (30 min each) enables high throughput. The method was applied to real urine samples from different patients being treated with some of these pharmaceuticals. Some SSRI metabolites were also detected and tentatively identified.


Assuntos
Antidepressivos de Segunda Geração/urina , Cromatografia Gasosa-Espectrometria de Massas/métodos , Inibidores Seletivos de Recaptação de Serotonina/urina , Microextração em Fase Sólida/métodos , Citalopram/urina , Cicloexanóis/urina , Fluoxetina/urina , Fluvoxamina/urina , Humanos , Mianserina/análogos & derivados , Mianserina/urina , Mirtazapina , Reprodutibilidade dos Testes , Sertralina/urina , Cloridrato de Venlafaxina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA