Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 398
Filtrar
2.
BMC Cardiovasc Disord ; 24(1): 422, 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39135174

RESUMO

BACKGROUND: Despite impressive improvements in the safety profile of Transcatheter aortic valve replacement (TAVR), the risk for peri-procedural stroke after TAVR has not declined substantially. In an effort to reduce periprocedural stroke, cerebral embolic protection (CEP) devices have been utilized but have yet to demonstrate benefit in all-comers. There is a paucity of data supporting the utilization of CEP in TAVR patients with an anticipated high risk for peri-procedural stroke. METHODS: The Transcatheter Aortic Valve Replacement In-Hospital Stroke (TASK) score is a clinical risk tool for predicting the in-hospital stroke risk of patients undergoing transfemoral TAVR. This score was used to identify high-risk patients and calculate the expected in-hospital stroke risk. This was a single-centre cohort study in all consecutive TAVR patients who had placement of CEP. The observed versus expected ratio for peri-procedural stroke was calculated. To obtain 95% credible intervals, we used 1000 bootstrapped samples of the original cohort sample size without replacement and recalculated the TASK predicted scores. RESULTS: The study included 103 patients. The median age was 83 (IQR 78,89). 63 were male (61.1%) and 45 (43.69%) had a history of previous Stroke or TIA. Two patients had an in-hospital stroke after TAVR (1.94%). The expected risk of in-hospital stroke based on the TASK score was 3.39% (95% CI 3.07-3.73). The observed versus expected ratio was 0.57 (95% CI 0.52-0.64). CONCLUSION: In this single-center study, we found that in patients undergoing TAVR with high stroke risk, CEP reduced the in-hospital stroke risk by 43% when compared with the risk-score predicted rate. CLINICAL TRIAL NUMBER: N/A.


Assuntos
Dispositivos de Proteção Embólica , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Fatores de Risco , Medição de Risco , Idoso de 80 Anos ou mais , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Fatores de Tempo , Embolia Intracraniana/prevenção & controle , Embolia Intracraniana/etiologia , Embolia Intracraniana/epidemiologia , Embolia Intracraniana/diagnóstico , Estudos Retrospectivos , Técnicas de Apoio para a Decisão , Valor Preditivo dos Testes
3.
J Am Coll Cardiol ; 84(8): 712-722, 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39142725

RESUMO

BACKGROUND: Acute brain infarction detected by diffusion-weighted magnetic resonance imaging (DW-MRI) is common after transcatheter aortic valve replacement (TAVR), but its clinical relevance is uncertain. OBJECTIVES: The authors investigated the relationship between DW-MRI total lesion number (TLN), individual lesion volume (ILV), and total lesion volume (TLV) and clinical stroke outcomes after TAVR. METHODS: Patient-level data were pooled from 4 prospective TAVR embolic protection studies, with consistent predischarge DW-MRI acquisition and core laboratory analysis. C-statistic was used to determine the best DW-MRI measure associated with clinical stroke. RESULTS: A total of 495 of 603 patients undergoing TAVR completed the predischarge DW-MRI. At 30 days, the rate of clinical ischemic stroke was 6.9%. Acute ischemic brain injury was seen in 85% of patients with 5.5 ± 7.3 discrete lesions per patient, mean ILV of 78.2 ± 257.1 mm3, and mean TLV of 555 ± 1,039 mm3. The C-statistic was 0.84 for TLV, 0.81 for number of lesions, and 0.82 for maximum ILV in predicting ischemic stroke. On the basis of the TLV cutpoint as defined by receiver operating characteristic (ROC), patients with a TLV >500 mm3 (vs TLV ≤500 mm3) had more ischemic stroke (18.2% vs 2.3%; P < 0.0001), more disabling strokes (8.8% vs 0.9%; P < 0.0001), and less complete stroke recovery (44% vs 62.5%; P = 0.001) at 30 days. CONCLUSIONS: Our study confirms that the number, size, and total volume of acute brain infarction defined by DW-MRI are each associated with clinical ischemic strokes, disabling strokes, and worse stroke recovery in patients undergoing TAVR and may have value as surrogate outcomes in stroke prevention trials. (A Prospective, Randomized Evaluation of the TriGuard™ HDH Embolic Deflection Device During TAVI [DEFLECT III]; NCT02070731) (A Study to Evaluate the Neuro-embolic Consequences of TAVR [NeuroTAVR]; NCT02073864) (The REFLECT Trial: Cerebral Protection to Reduce Cerebral Embolic Lesions After Transcatheter Aortic Valve Implantation [REFLECT I]; NCT02536196) (The REFLECT Trial: Cerebral Protection to Reduce Cerebral Embolic Lesions After Transcatheter Aortic Valve Implantation [REFLECT II]; NCT02536196).


Assuntos
Imagem de Difusão por Ressonância Magnética , Substituição da Valva Aórtica Transcateter , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Feminino , Idoso de 80 Anos ou mais , Idoso , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estudos Prospectivos , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , AVC Isquêmico/etiologia , AVC Isquêmico/diagnóstico por imagem , Relevância Clínica
4.
JACC Cardiovasc Interv ; 17(15): 1795-1807, 2024 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-39142756

RESUMO

BACKGROUND: The Valve Academic Research Consortium (VARC)-3 definition for neurologic events after transcatheter aortic valve replacement (TAVR) lacks clinical validation. OBJECTIVES: This study sought to determine the incidence, predictors, and clinical impact of neurologic events following TAVR as defined by VARC-3 criteria. METHODS: This was a multicenter study including 2,924 patients with severe aortic stenosis undergoing TAVR. Based on Neurologic Academic Research Consortium (NeuroARC) classification, neurologic events were classified as NeuroARC type 1 (stroke), NeuroARC type 2 (covert central nervous system injury), and NeuroARC type 3 (transient ischemic attack and delirium). Baseline, procedural, and follow-up data were prospectively collected in a dedicated database. RESULTS: After a median follow-up of 13 (7-37) months, neurologic events occurred in 471 patients (16.1%), NeuroARC type 1, 2, and 3 in 37.4%, 4.7%, and 58.0% of cases, respectively, and the majority (58.6%) were periprocedural. Advanced age, chronic kidney disease, atrial fibrillation, major vascular complications, and in-hospital bleeding determined an increased risk of periprocedural events (P < 0.03 for all). Neurologic events occurring during the periprocedural time frame were independently associated with a substantial increase in mortality at 1 year after the intervention (HR: 1.91; 95% CI: 1.23-2.97; P = 0.004). However, although NeuroARC type 1 was associated with an increased mortality risk (IRR: 3.38; 95% CI: 2.30-5.56; P < 0.001 and IRR: 21.7; 95% CI: 9.63-49.1; P < 0.001 for ischemic and hemorrhagic stroke, respectively), the occurrence of NeuroARC type 3 events had no impact on mortality. CONCLUSIONS: Neurologic events after TAVR were associated with poorer short- and long-term survival. This correlation was related to the type of NeuroARC event defined by the VARC-3 criteria. Given the negative impact on clinical outcomes, every attempt should be made to reduce the risk of neurologic complications after TAVR.


Assuntos
Estenose da Valva Aórtica , Ataque Isquêmico Transitório , Índice de Gravidade de Doença , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Fatores de Risco , Feminino , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Incidência , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso de 80 Anos ou mais , Fatores de Tempo , Medição de Risco , Ataque Isquêmico Transitório/etiologia , Ataque Isquêmico Transitório/mortalidade , Ataque Isquêmico Transitório/epidemiologia , Resultado do Tratamento , Acidente Vascular Cerebral/mortalidade , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/epidemiologia , Delírio/epidemiologia , Delírio/etiologia , Delírio/diagnóstico , Delírio/mortalidade , Bases de Dados Factuais , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem
7.
J Am Heart Assoc ; 13(15): e034298, 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39101495

RESUMO

BACKGROUND: Studies have shown inconclusive results on the effectiveness of cerebral protection devices (CPDs) with transcatheter aortic valve replacement. We aimed to analyze the national statistics on stroke and other outcomes with CPD use. METHODS AND RESULTS: The Nationwide Readmissions Database (2017-2020) was queried to obtain data on patients undergoing transcatheter aortic valve replacement. Outcomes were compared between patients with a CPD and patients without a CPD. Of 271 804 patients undergoing transcatheter aortic valve replacement, CPD was used in 7.3% of patients. In a multivariable logistic regression analysis, CPD use was not associated with lower overall stroke rates (1.6% versus 1.9% without CPD; odds ratio, 0.95 [95% CI, 0.84-1.07]; P=0.364), but it was significantly associated with lower major stroke rates (1.2% versus 1.5% without CPD; odds ratio, 0.85 [95% CI, 0.74-0.98]; P=0.02). Patients with a CPD also had a shorter length of stay, higher routine discharges to home/self-care (74.9% versus 70.6%), and lower mortality rates (0.7% versus 1.3%). The 30-day (9.6% versus 11.7%) and 180-day (24.6% versus 28.2%) readmission rates were significantly lower in the CPD cohort. Among patients who developed stroke, patients with a CPD had more frequent routine discharges. Prior valve surgery was associated with the highest risk of overall and major stroke. CONCLUSIONS: CPD use during transcatheter aortic valve replacement was not independently associated with a lower risk of overall stroke but was associated with a lower risk of major stroke in a multivariable model. Data from future randomized trials that may offset any potential confounders in our study are required to help identify patients who would benefit from the use of these devices.


Assuntos
Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Masculino , Feminino , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Idoso de 80 Anos ou mais , Idoso , Fatores de Risco , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Estados Unidos/epidemiologia , Dispositivos de Proteção Embólica , Medição de Risco/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Resultado do Tratamento , Readmissão do Paciente/estatística & dados numéricos , Estudos Retrospectivos , Bases de Dados Factuais , Incidência , Fatores de Tempo
8.
Radiologia (Engl Ed) ; 66(4): 340-352, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39089794

RESUMO

Transcatheter aortic valve implantation (TAVI) is the alternative to surgical valve replacement, expanding its indications in the latest guidelines. Multimodal CT (MDCT) is essential in patient selection and detection of complications. Vascular complications are frequent, so it is important to analyse the anatomy of the vessels before the procedure. Regarding annular ruptures and ventricular perforations, the volume and distribution of calcium and the ventricular diameter play an important role. Finally, valve migration is a rare complication that can occur both during and after TAVI. Proper planning of the MDCT procedure reduces the risk of complications and gives the interventional cardiologist security both before and during the procedure.


Assuntos
Tomografia Computadorizada Multidetectores , Complicações Pós-Operatórias , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Cuidados Pré-Operatórios/métodos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem
9.
EuroIntervention ; 20(13): e793-e805, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38949240

RESUMO

Periprocedural stroke after transcatheter aortic valve implantation (TAVI) remains a significant issue, which is associated with high morbidity, and is increasingly important as intervention shifts to younger and lower-risk populations. Over the last decade of clinical experience with TAVI, the incidence of periprocedural stroke has stayed largely unchanged, although it is prone to underreporting due to variation in ascertainment methods. The aetiology of stroke in TAVI patients is multifactorial, and changing risk profiles, differing study populations, and frequent device iterations have made it difficult to discern consistent risk factors. The objective of this review is to analyse and clarify the contemporary published literature on the epidemiology and mechanisms of neurological events in TAVI patients and evaluate potential preventive measures. This summary aims to improve patient risk assessment and refine case selection for cerebral embolic protection devices, while also providing a foundation for designing future trials focused on stroke prevention.


Assuntos
Estenose da Valva Aórtica , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Estenose da Valva Aórtica/cirurgia , Medição de Risco , Valva Aórtica/cirurgia , Incidência , Resultado do Tratamento , Dispositivos de Proteção Embólica
13.
Trials ; 25(1): 436, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38956681

RESUMO

BACKGROUND: Compared to traditional thoracotomy, transapical transcatheter aortic valve implantation (TAVI) surgery offers reduced trauma and faster recovery, fostering the adoption of enhanced recovery after surgery (ERAS) protocols in cardiac surgery. Despite these advancements, postoperative pain management has received insufficient attention. The potential effects of multi-mode analgesia, including ultrasound-guided serratus anterior plane block (SAPB), on postoperative pain and early quality of recovery have not been widely studied, lacking comprehensive prospective evidence. Therefore, this study aims to investigate the impact of SAPB combined with general anesthesia on early recovery quality and analgesic efficacy in transapical TAVI patients. METHODS: This prospective, randomized controlled study will enroll 70 patients undergoing transapical TAVI, randomly allocated to either the SAPB group or the control group. The primary outcome, assessed using Quality of Recovery-40 (QOR-40) scale, focuses on the quality of recovery at 24 h and 48 h postoperatively. Secondary outcomes include the visual analog scale (VAS) pain scores at rest and during coughing at 6 h, 12 h, 24 h, and 48 h after surgery, frequency of patient-controlled analgesia (PCA) utilization at 24 h and 48 h, opioid consumption at 24 h and 48 h, time and frequency of rescue analgesia and severe pain at 24 h and 48 h, incidence of nausea and vomiting at 48 h after surgery, and dosage of antiemetic drugs. DISCUSSION: The purpose of our study is to evaluate the effects of ultrasound-guided SAPB combined with general anesthesia on postoperative early quality of recovery and analgesia in transapical TAVI patients. The results obtained may provide valuable insight for the implementation of multi-mode analgesia and enhanced ERAS in this specific patient population. TRIAL REGISTRATION: China Clinical Trial Register ChiCTR2300068584. Registered on 24 February 2023.


Assuntos
Anestesia Geral , Bloqueio Nervoso , Dor Pós-Operatória , Substituição da Valva Aórtica Transcateter , Ultrassonografia de Intervenção , Humanos , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/prevenção & controle , Dor Pós-Operatória/diagnóstico , Bloqueio Nervoso/métodos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento , Analgesia Controlada pelo Paciente/métodos , Recuperação de Função Fisiológica , Masculino , Feminino , Fatores de Tempo , Medição da Dor , Idoso , China , Manejo da Dor/métodos
15.
Expert Rev Cardiovasc Ther ; 22(7): 325-337, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38970466

RESUMO

INTRODUCTION: Over the past two decades, transcatheter aortic valve replacement (TAVR) has expanded its application across all surgical risk levels, including low-risk patients, where, due to longer life expectancy, reducing common pitfalls of TAVR is essential. To address these needs, many technological advancements have been developed. Myval and the new generation Myval Octacor (Meril Life Sciences Pvt. Ltd) are novel balloon-expandable (BE) transcatheter heart valve (THV) systems designed for the treatment of severe aortic stenosis. AREAS COVERED: This review aims to illustrate the design features of these novel THVs and the main evidence from available studies. Furthermore, we provide evidence of these THVs' performance in challenging scenarios such as extra-large aortic annuli, bicuspid aortic valves, and valve-in-valve/valve-in-ring procedures. EXPERT OPINION: Myval and Myval Octacor have demonstrated comparable early safety and clinical efficacy to the leading contemporary THVs, exhibiting remarkably low rates of moderate to severe paravalvular leak (PVL) and permanent pacemaker implantation (PPI). The wide range of sizes offered by the Myval family may minimize the risk of under-/oversizing, potentially explaining the lower rates of the aforementioned phenomena. Moreover, the presence of both internal skirt and external reinforced cuff may also explain the low rate of moderate to severe PVL.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Índice de Gravidade de Doença , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem
17.
Braz J Cardiovasc Surg ; 39(4): e20230088, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39038027

RESUMO

INTRODUCTION: Diabetes mellitus (DM) in patients undergoing cardiac transcatheter or surgical interventions usually is correlated with poor outcomes. Transcatheter aortic valve implantation (TAVI) has been developed as a therapy choice for inoperable, high-, or intermediate-risk surgical patients with severe aortic stenosis (AS). OBJECTIVE: To evaluate the impact of DM and hemoglobin A1c (HbA1c) on outcomes and survival after TAVI. METHODS: Five hundred and fifty-two symptomatic severe AS patients who underwent TAVI, of whom 164 (29.7%) had DM, were included in this retrospective study. Follow-up was performed after 30 days, six months, and annually. RESULTS: The device success and risks of procedural-related complications were similar between patients with and without DM, except for acute kidney injury, which was more frequent in the DM group (2.4% vs. 0%, P=0.021). In-hospital and first-year mortality were similar between the groups (4.9% vs. 3.6%, P=0.490 and 15.0% vs. 11.2%, P=0.282, respectively). There was a statistical difference between HbA1c ≥ 6.5 and HbA1c ≤ 6.49 groups in total mortality (34.4% vs. 15.8%, P<0.001, respectively). The only independent predictors were Society of Thoracic Surgeons score (hazard ratio [HR] 1.28, 95% confidence interval [CI] 1.09-1.51; P=0.003) and HbA1c level ≥ 6.5 (HR 10.78, 95% CI 2.58-21.50; P=0.003) in multivariable logistic regression analysis. CONCLUSION: In this study, we conclude that DM was not correlated with an increased mortality risk or complication rates after TAVI. Also, it was shown that mortality was higher in patients with HbA1c ≥ 6.5, and it was an independent predictor for long-term mortality.


Assuntos
Estenose da Valva Aórtica , Diabetes Mellitus , Hemoglobinas Glicadas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Feminino , Estudos Retrospectivos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Idoso de 80 Anos ou mais , Idoso , Resultado do Tratamento , Diabetes Mellitus/mortalidade , Hemoglobinas Glicadas/análise , Fatores de Risco , Complicações Pós-Operatórias/mortalidade , Fatores de Tempo , Índice de Gravidade de Doença , Mortalidade Hospitalar
18.
Braz J Cardiovasc Surg ; 39(4): e20230155, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39038084

RESUMO

OBJECTIVE: This study aimed to compare hemodynamic performances and clinical outcomes of patients with small aortic annulus (SAA) who underwent aortic valve replacement by means of sutureless aortic valve replacement (SUAVR) or transcatheter aortic valve implantation (TAVI). METHODS: From 2015 to 2020, 622 consecutive patients with SAA underwent either SUAVR or TAVI. Through a 1:1 propensity score matching analysis, two homogeneous groups of 146 patients were formed. Primary endpoint: all cause-death at 36 months. Secondary endpoints: incidence of moderate to severe patient-prosthesis mismatch (PPM) and incidence of major adverse cardiovascular and cerebrovascular events (MACCEs). RESULTS: All-cause death at three years was higher in the TAVI group (SUAVR 12.2% vs. TAVI 21.0%, P=0.058). Perioperatively, comparable hemodynamic performances were recorded in terms of indexed effective orifice area (SUAVR 1.12 ± 0.23 cm2/m2 vs. TAVI 1.17 ± 0.28 cm2/m2, P=0.265), mean transvalvular gradients (SUAVR 12.9 ± 5.3 mmHg vs. TAVI 12.2 ± 6.2 mmHg, P=0.332), and moderate-to-severe PPM (SUAVR 4.1% vs. TAVI 8.9%, P=0.096). TAVI group showed a higher cumulative incidence of MACCEs at 36 months (SUAVR 18.1% vs. TAVI 32.6%, P<0.001). Pacemaker implantation (PMI) and perivalvular leak ≥ 2 were significantly higher in TAVI group and identified as independent predictors of mortality (PMI: hazard ratio [HR] 3.05, 95% confidence interval [CI] 1.34-6.94, P=0.008; PPM: HR 2.72, 95% CI 1.25-5.94, P=0.012). CONCLUSION: In patients with SAA, SUAVR and TAVI showed comparable hemodynamic performances. Moreover, all-cause death and incidence of MACCEs at follow-up were significantly higher in TAVI group.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Hemodinâmica , Pontuação de Propensão , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Feminino , Hemodinâmica/fisiologia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Resultado do Tratamento , Procedimentos Cirúrgicos sem Sutura/métodos , Próteses Valvulares Cardíacas , Estudos Retrospectivos , Complicações Pós-Operatórias , Implante de Prótese de Valva Cardíaca/métodos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA