Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Clin Physiol Funct Imaging ; 34(1): 1-9, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23869947

RESUMO

This review imparts the history and the present status of the indicator dilution technique with quantitative bolus injection. The first report on flow measurement with this technique appeared 100 years ago. In 1928, the use of intravascular dyes made possible a widespread application in animals and human during the next decades. Multiple indicators, radioactive tracers, inlet-outlet detection and residue detection were introduced in the 1950s and 1960s, and refined along with the development of indicator kinetics. From the 1970s, a wide clinical use in the study of heart, brain, lungs, liver and kidneys developed, and powerful computers in the 1980s and 1990s accorded the technique a new dimension. Today, the indicator dilution technique, on one hand, is applied in the same way as 100 years ago, on the other hand it forms the basis of quantitative SPECT, positron emission tomography, and dynamic MR scans. The technique still undergoes refinement and elaboration as a lasting concept with a high potential for further development.


Assuntos
Técnica de Diluição de Corante/história , Hemodinâmica , Técnica de Diluição de Radioisótopos/história , Animais , Velocidade do Fluxo Sanguíneo , Corantes/administração & dosagem , Técnica de Diluição de Corante/tendências , História do Século XX , História do Século XXI , Humanos , Injeções , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Valor Preditivo dos Testes , Técnica de Diluição de Radioisótopos/tendências , Radioisótopos/administração & dosagem , Fluxo Sanguíneo Regional , Tomografia Computadorizada de Emissão de Fóton Único
2.
Ann Biomed Eng ; 28(8): 836-48, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11144667

RESUMO

In 1824 Hering introduced an indicator-dilution method for measuring blood velocity. Not until 1897 was the method extended by Stewart to measure blood (volume) flow. For more than two decades, beginning in 1928, Hamilton and colleagues measured blood flow, including cardiac output. They proposed that the first-passsage indicator concentration-time curve could be recovered from observed curves that included recirculation by semilogarithmic extrapolation of the early downslope. Others followed with attempts to fit the complete first-passage curve by various forms, such as by the sum of three exponential terms (three well-stirred compartments in series). Stephenson (1948) thought of looking at indicator-dilution curves as convolutions of indicator input with a probability density function of traversal times through the system. Meier and I reached a similar conclusion, and extended it. The fundamental notion is that there exists a probability density function of transit times, h(t), through the system. We proved that mean transit time t= V/F, where V is volume in which the indicator is distributed. Thus, V, F, and t might all be calculated, or r alone might suffice if one wanted only to know relative blood flow. I extended the analysis to include residue detection of indicator remaining in the system, so that V, F, and could be calculated by external monitoring. Chinard demonstrated the value of simultaneous multiple indicator-dilution curves with various volumes of distribution. Goresky extended the technique to study cell uptake and metabolism. He also found a transform of indicator-dilution output curves (equivalent to multiplying the ordinate by tand dividing the time by t) which made congruent the family of unalike curves obtained by simultaneous injection of indicators with different volumes of distribution. Bassingthwaighte showed the same congruency with the transform of outputs of a single indicator introduced into a system with experimentally varied blood flows. We showed the same congruency for the pulmonary circulation, adding a correction for delays. Success of these transforms suggests that the architecture of the vascular network is a major determinant of the shape of density functions of transit times through the system, and that there is in this architecture, a high degree of self-similarity, implying that the fractal power function is a component in shaping the observed density of transit times. I proposed that the distribution of capillary critical opening pressures, which describes recruitment of vascular paths, may be important in shaping indicator-dilution curves, and that h(t) may be derived from flow-pressure and volume-pressure curves under some circumstances.


Assuntos
Determinação do Volume Sanguíneo/história , Técnica de Diluição de Corante/história , Hemorreologia/história , Animais , Velocidade do Fluxo Sanguíneo/fisiologia , Determinação do Volume Sanguíneo/métodos , Hemorreologia/métodos , História do Século XIX , História do Século XX , Humanos , Modelos Biológicos , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA