Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 206
Filtrar
1.
Clin Neurophysiol ; 135: 179-187, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34963555

RESUMO

OBJECTIVE: The diagnostic values of measuring median nerve (MN) stiffness and vascularity with shear wave elastography (SWE) and high-definition (HD) color were investigated in carpal tunnel syndrome (CTS). METHODS: Seventy patients (123 wrists) with CTS and thirty-five healthy volunteers (70 wrists) were enrolled. Based on nerve conduction studies (NCS), the patients were subdivided into NCS-negative, mild-to-moderate, and severe CTS groups. MN and abductor pollicis brevis (APB) SWE and MN HD color were performed on a longitudinal plane. RESULTS: The mild-to-moderate and severe CTS groups showed increased MN stiffness at the wrist and MN stiffness ratio (wrist-to forearm) compared with the control (p < 0.001). The NCS-negative CTS group showed increased MN stiffness at the wrist (p = 0.022) and MN stiffness ratio (p = 0.032) compared with the control. The severe CTS group showed increased MN stiffness at the wrist compared with the mild-to-moderate CTS group (p = 0.034). The cutoff-values in diagnosing NCS-confirmed CTS were 50.12 kPa for MN stiffness at the wrist, 1.91 for MN stiffness ratio, and grade 1 for HD color. CONCLUSIONS: SWE and HD color are good supportive tools in diagnosing and assessing severity in CTS. SIGNIFICANCE: SWE and HD color demonstrated that MN in CTS was associated with increased stiffness and hypervascularity.


Assuntos
Síndrome do Túnel Carpal/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia Doppler em Cores/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Vasos Sanguíneos/diagnóstico por imagem , Síndrome do Túnel Carpal/fisiopatologia , Técnicas de Imagem por Elasticidade/normas , Eletrodiagnóstico/métodos , Eletrodiagnóstico/normas , Feminino , Humanos , Masculino , Nervo Mediano/irrigação sanguínea , Nervo Mediano/fisiopatologia , Pessoa de Meia-Idade , Condução Nervosa , Sensibilidade e Especificidade , Ultrassonografia Doppler em Cores/normas
3.
Medicine (Baltimore) ; 100(35): e27104, 2021 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-34477149

RESUMO

ABSTRACT: To evaluate the diagnostic values of shear wave elastography (SWE) alone and in combination with the Toronto clinical scoring system (TCSS) on diabetic peripheral neuropathy (DPN) in patients with type 2 diabetes mellitus (T2DM).The study included 41 DPN patients, 42 non-DPN patients, and 21 healthy volunteers. Conventional ultrasonography and SWE were performed on the 2 sides of the tibial nerves, and cross-sectional area (CSA) and nerve stiffness were measured. TCSS was applied to all patients. A receiver operating characteristic curve analysis was performed.The stiffness of the tibial nerve, as measured as mean, minimum or maximum elasticity, was significantly higher in patients in the DPN group than the other groups (P < .05). The tibial nerve of subjects in the non-DPN group was significantly stiffer compared to the control group (P < .05). There was no significant difference of the tibial nerve CSA among the 3 groups (P > .05). Mean elasticity of the tibial nerve with a cutoff of 71.3 kPa was the most sensitive (68.3%) and had a higher area under the curve (0.712; 0.602-0.806) among the 3 shear elasticity indices for diagnosing DPN when used alone. When combining SWE with TCSS in diagnosing DPN, the most effective parameter was the EMax, which yielded a sensitivity of 100.00% and a specificity of 95.24%.SWE is a better diagnostic tool for DPN than the conventional ultrasonic parameter CSA, and a higher diagnostic value is attained when combining SWE with TCSS.


Assuntos
Nefropatias Diabéticas/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/normas , Projetos de Pesquisa , Idoso , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/fisiopatologia , Nefropatias Diabéticas/complicações , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doenças do Sistema Nervoso Periférico/classificação , Doenças do Sistema Nervoso Periférico/diagnóstico por imagem , Curva ROC , Reprodutibilidade dos Testes
4.
Cells ; 10(5)2021 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-34063640

RESUMO

In recent years contrast-enhanced ultrasound (CEUS) has been an emerging diagnostic modality for the detection of acute gastrointestinal (GI) graft-versus-host disease (GvHD) in patients after allogeneic stem cell transplantation. However, broad clinical usage has been partially limited by its high dependence on the expertise of an experienced examiner. Thus, the aim of this study was to facilitate detection of acute GI GvHD by implementing false color-coded parametric imaging of CEUS. As such, two inexperienced examiners with basic knowledge in abdominal and vascular ultrasound analyzed parametric images obtained from patients with clinical suspicion for acute GvHD in a blinded fashion. As diagnostic gold standard, histopathological GvHD severity score on intestinal biopsies obtained from lower GI tract endoscopy was performed. The evaluation of parametric images by the two inexperienced ultrasound examiners in patients with histological confirmation of acute GI GvHD was successful in 17 out of 19 patients (89%) as opposed to analysis of combined B-mode ultrasound, strain elastography, and CEUS by an experienced examiner, which was successful in 18 out of 19 of the patients (95%). Therefore, CEUS with parametric imaging of the intestine was technically feasible and has the potential to become a valuable diagnostic tool for rapid and widely accessible detection of acute GvHD in clinical practice.


Assuntos
Procedimentos Cirúrgicos do Sistema Digestório/efeitos adversos , Técnicas de Imagem por Elasticidade/métodos , Doença Enxerto-Hospedeiro/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Transplante de Células-Tronco/efeitos adversos , Ultrassonografia/métodos , Adulto , Idoso , Meios de Contraste , Técnicas de Imagem por Elasticidade/normas , Feminino , Doença Enxerto-Hospedeiro/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/patologia , Transplante Homólogo , Ultrassonografia/normas
5.
Andrology ; 9(5): 1331-1355, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34089245

RESUMO

BACKGROUND: Ultrasonography is the gold standard imaging method for scrotal investigation. Colour Doppler ultrasonography, contrast-enhanced ultrasonography and sonoelastography allow sonographers to assess size, echotexture, vascular features and stiffness of the scrotal organs and abnormalities. Scrotal ultrasonography has been used to investigate male reproductive health, scrotal pain, masses and trauma. However, ultrasonography thresholds/classifications used to distinguish normal and pathologic features of the scrotal organs have changed over time, and have not yet been fully standardized. OBJECTIVES: To evaluate historical trends for the standards in scrotal ultrasonography: what was, what is and what will be normal. METHODS: An extensive Medline search was performed identifying the most relevant studies in the English language from inception to date. RESULTS: We provide here (i) a brief overview of the history of ultrasonography, (ii) current indications for scrotal ultrasonography and (iii) previous and current normal values, cut-offs and classifications of the main colour-Doppler ultrasonography parameters/characteristics of the scrotal organs, as derived from recent guidelines and evidence-based studies. In addition, we report recommendations and the clinical utility of contrast-enhanced ultrasonography and sonoelastography. Finally, we discuss critical issues needing further evidence and future directions to fill in the current gaps. DISCUSSION: Several studies on scrotal ultrasonography are available. However, guidelines/recommendations dealing with specific ultrasonography applications have been published only in recent years. More recently, the European Academy of Andrology published evidence-based scrotal colour-Doppler ultrasonography reference ranges/normative parameters derived from a cohort of healthy, fertile men. In addition, a standardization of the methodology to evaluate qualitative and quantitative colour-Doppler ultrasonography parameters was reported. Other international societies reported indications, methodological standards, clinical utility and limitations of contrast-enhanced ultrasonography and sonoelastography. CONCLUSIONS: To date, colour-Doppler ultrasonography normative values for the scrotal organs are available. However, a wide international consensus on assessment and classification of several ultrasonography parameters is still lacking. An alignment of the world societies on these issues is advocated.


Assuntos
Técnicas de Imagem por Elasticidade/tendências , Doenças dos Genitais Masculinos/diagnóstico por imagem , Guias de Prática Clínica como Assunto , Escroto/diagnóstico por imagem , Ultrassonografia/tendências , Técnicas de Imagem por Elasticidade/normas , História do Século XXI , Humanos , Masculino , Padrões de Referência , Valores de Referência , Ultrassonografia/métodos , Ultrassonografia/normas , Ultrassonografia Doppler em Cores/normas , Ultrassonografia Doppler em Cores/tendências
6.
Medicine (Baltimore) ; 100(23): e26183, 2021 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-34115001

RESUMO

BACKGROUND: With high diagnostic accuracy, magnetic resonance elastography (MRE) is a noninvasive tool and can be adopted to measure liver stiffness (LS). In this study, meta-analysis was carried out to further evaluate whether LS measured by MRE can predict early recurrence in patients with hepatocellular carcinoma (HCC). METHODS: PUBMED, EMBASE, Web of Science, China National Knowledge Infrastructure, and Cochrane Library database were searched for studies related to LS measured by MRE in the prediction of recurrence in patients with HCC. Survival outcome was estimated by hazard ratios and 95% confidence intervals. Meta-analysis was conducted with the Stata 16.0. RESULTS: The results of this meta-analysis will be submitted to a peer-reviewed journal for publication. CONCLUSION: This study will provide evidence support for LS measured by MRE in predicting the recurrence of HCC. ETHICS AND DISSEMINATION: The private information from individuals will not be published. This systematic review also should not damage participants' rights. Ethical approval is not available. The results may be published in a peer-reviewed journal or disseminated in relevant conferences. OSF REGISTRATION NUMBER: DOI 10.17605/ OSF.IO / SURH3.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Protocolos Clínicos , Técnicas de Imagem por Elasticidade/normas , Fígado/fisiopatologia , Carcinoma Hepatocelular/classificação , Técnicas de Imagem por Elasticidade/instrumentação , Técnicas de Imagem por Elasticidade/métodos , Humanos , Fígado/diagnóstico por imagem , Metanálise como Assunto , Modelos de Riscos Proporcionais , Recidiva , Revisões Sistemáticas como Assunto , Pesos e Medidas/instrumentação , Pesos e Medidas/normas
7.
Medicine (Baltimore) ; 100(23): e26200, 2021 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-34115003

RESUMO

ABSTRACT: We assessed the performance characteristics of the Fibrosis-4 (FIB-4) score in a veteran population with chronic hepatitis C virus (HCV) infection and used vibration controlled transient elastography (VCTE) as the gold standard.All VCTE studies were performed by a single operator on United States veterans with HCV infection presenting for care at the Atlanta VA Medical Center (AVAMC) over a 2 year period. VCTE liver stiffness measurements (LSM) were categorized as cirrhotic if LSM was >12.5 kPa and non-cirrhotic if LSM was ≤12.5 kPa. FIB-4 scores ≤3.25 were considered non-cirrhotic and scores >3.25 were considered cirrhotic. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for the FIB-4 score. A second analysis was done which identified and excluded indeterminate FIB-4 scores, defined as any value between 1.45 and 3.25.When FIB-4 was used to screen for liver cirrhosis using VCTE as the gold standard, sensitivity was 42%, specificity was 88%, PPV was 62%, and NPV was 76%. When indeterminate FIB-4 scores were excluded from the analysis, sensitivity was 95%, specificity was 61%, PPV was 62%, and NPV was 94.4%. In a veteran population with chronic HCV infection, we found the sensitivity of the FIB-4 score to be unacceptably low for ruling out liver cirrhosis when using a binary cutoff at 3.25. Using a second staging method like VCTE may be an effective way to screen for liver cirrhosis in persons with chronic HCV, especially when the FIB-4 score is in the indeterminate range.


Assuntos
Técnicas de Imagem por Elasticidade/normas , Hepatite C/complicações , Cirrose Hepática/classificação , Cirrose Hepática/diagnóstico por imagem , Índice de Gravidade de Doença , Adulto , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/estatística & dados numéricos , Feminino , Georgia , Hepacivirus/patogenicidade , Hepatite C/diagnóstico por imagem , Humanos , Cirrose Hepática/fisiopatologia , Masculino , Pessoa de Meia-Idade , Curva ROC , Vibração
8.
J Hepatol ; 75(4): 770-785, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33991635

RESUMO

BACKGROUND AND AIMS: Vibration-controlled transient elastography (VCTE), point shear wave elastography (pSWE), 2-dimensional shear wave elastography (2DSWE), magnetic resonance elastography (MRE), and magnetic resonance imaging (MRI) have been proposed as non-invasive tests for patients with non-alcoholic fatty liver disease (NAFLD). This study evaluated their diagnostic accuracy for liver fibrosis and non-alcoholic steatohepatitis (NASH). METHODS: PubMED/MEDLINE, EMBASE and the Cochrane Library were searched for studies examining the diagnostic accuracy of these index tests, against histology as the reference standard, in adult patients with NAFLD. Two authors independently screened and assessed methodological quality of studies and extracted data. Summary estimates of sensitivity, specificity and area under the curve (sAUC) were calculated for fibrosis stages and NASH, using a random effects bivariate logit-normal model. RESULTS: We included 82 studies (14,609 patients). Meta-analysis for diagnosing fibrosis stages was possible in 53 VCTE, 11 MRE, 12 pSWE and 4 2DSWE studies, and for diagnosing NASH in 4 MRE studies. sAUC for diagnosis of significant fibrosis were: 0.83 for VCTE, 0.91 for MRE, 0.86 for pSWE and 0.75 for 2DSWE. sAUC for diagnosis of advanced fibrosis were: 0.85 for VCTE, 0.92 for MRE, 0.89 for pSWE and 0.72 for 2DSWE. sAUC for diagnosis of cirrhosis were: 0.89 for VCTE, 0.90 for MRE, 0.90 for pSWE and 0.88 for 2DSWE. MRE had sAUC of 0.83 for diagnosis of NASH. Three (4%) studies reported intention-to-diagnose analyses and 15 (18%) studies reported diagnostic accuracy against pre-specified cut-offs. CONCLUSIONS: When elastography index tests are acquired successfully, they have acceptable diagnostic accuracy for advanced fibrosis and cirrhosis. The potential clinical impact of these index tests cannot be assessed fully as intention-to-diagnose analyses and validation of pre-specified thresholds are lacking. LAY SUMMARY: Non-invasive tests that measure liver stiffness or use magnetic resonance imaging (MRI) have been suggested as alternatives to liver biopsy for assessing the severity of liver scarring (fibrosis) and fatty inflammation (steatohepatitis) in patients with non-alcoholic fatty liver disease (NAFLD). In this study, we summarise the results of previously published studies on how accurately these non-invasive tests can diagnose liver fibrosis and inflammation, using liver biopsy as the reference. We found that some techniques that measure liver stiffness had a good performance for the diagnosis of severe liver scarring.


Assuntos
Técnicas de Imagem por Elasticidade/normas , Imageamento por Ressonância Magnética/normas , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Adulto , Área Sob a Curva , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/estatística & dados numéricos , Humanos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Hepatopatia Gordurosa não Alcoólica/diagnóstico , Curva ROC
9.
PLoS One ; 16(5): e0250300, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33939744

RESUMO

BACKGROUND & AIM: We studied FibroTouch (FT) and Fibroscan (FS) examination results and their repeatability when performed by healthcare personnel of different background. METHODS: FT and FS examinations were performed on patients with chronic liver disease by two operators, a doctor and a nurse, twice on each patient, at two different time points, independent of each other. RESULTS: The data for 163 patients with 1304 examinations was analyzed. There was strong correlation between FT and FS for attenuation parameter (Spearman's rho 0.76, p<0.001) and liver stiffness measurement (LSM) (Spearman's rho 0.70, p<0.001). However, FT produced higher value at lower attenuation parameter and LSM, and lower value at higher attenuation parameter and LSM. There was substantial agreement when using 15kPa LSM cut-off, but only moderate agreement when using 10kPa and 20kPa LSM cut-offs and 248dB/m, 268dB/m and 280dB/m attenuation parameter cut-offs. The IQR for attenuation parameter and IQR/median for LSM were significantly lower for FT compared with FS (4dB/m vs 27dB/m, p<0.001, and 10 vs 12, p<0.001, respectively). The intra- and inter-observer reliability of attenuation parameter and LSM using FT and FS were good to excellent with intraclass correlation coefficients 0.89-0.99. FT had shorter examination time (33s vs 47s, p<0.001) and less invalid measurements (0 vs 2, p<0.001). CONCLUSION: Measurements obtained with FT and FS strongly correlated, but significant differences in their absolute values, consistency, examination time and number of invalid measurements were observed. Either device can be used by healthcare personnel of different backgrounds when sufficiently trained.


Assuntos
Técnicas de Imagem por Elasticidade/instrumentação , Hepatopatias/diagnóstico por imagem , Adulto , Idoso , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
10.
Medicine (Baltimore) ; 100(15): e24921, 2021 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-33847610

RESUMO

ABSTRACT: This study aimed to compare the accuracy and inter- and intra-observer reproducibility of the measured elasticity between 2 shear wave elastography systems. Three breast radiologists examined 8 targets of 4 different levels of stiffness (size: 11 mm, 4 mm) in an elasticity phantom (Customized 049A Elasticity QA Phantom, CIRS, Norfolk, VA, USA) using 2 different shear wave ultrasound elastography systems: SuperSonic Imagine (SSI) (SSI, Aix en Provence, France) and ShearScan (RS-80A, Samsung Medison, Seoul, Korea). Three radiologists performed ultrasound (US) elastography examinations for the phantom lesions using 2 equipment over a 1-week interval. Intra- and inter-observer reproducibility and the accuracy of the measured elasticity were analyzed and compared between the 2 systems. The accuracy of shape was also analyzed by shape-matching between B-mode and elastography color image. Intra-class correlation coefficients (ICC) were used in statistical analysis. For measured elasticity, the intra-observer and inter-observer reproducibility were excellent in both SSI and ShearScan (0.994 and 0.998). The overall accuracy was excellent in both systems, but the accuracy in small lesions (4 mm target) was lower in SSI than ShearScan (0.780 vs 0.967). The accuracy of shape-matching on the elastography image was 59.0% and 81.4% in the SSI and ShearScan, respectively. In conclusion, the SSI and ShearScan showed excellent intra- and inter-observer reproducibility. The accuracy of the Young's modulus was high in both the SSI and ShearScan, but the SSI showed decreased accuracy in measurement of elasticity in small targets and poor shape-matching between the B-mode image and color-coded elastography image.


Assuntos
Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/normas , Imagens de Fantasmas , Módulo de Elasticidade , Humanos , Variações Dependentes do Observador , Reprodutibilidade dos Testes
11.
Sci Rep ; 11(1): 7409, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33795822

RESUMO

Shear wave elastography (SWE) is a technique to non-invasively and quantitatively evaluate tissue stiffness. We aimed to investigate whether we can differentiate pancreatic cancer (PC) from normal pancreatic parenchyma (NPP) by SWE using transabdominal ultrasound. We investigated a total of 106 patients (84 with NPP and 22 with PC) whose pancreatic elastic modulus was measured by two-dimensional SWE (2D-SWE). Intra-rater reliability in this study was examined, and three measurements were sufficiently reliable. There were no differences between the two groups in factors that could affect SWE measurements. The median value of the elastic modulus was 5.70 kPa in the PC patients and 5.66 kPa in the NPP group, which was not significantly different (P = 0.785). On the contrary, the range was 8.64 kPa and 4.72 kPa, with a significantly greater range in the PC patients (P = 0.001). In conclusion, the median elastic modulus measured by 2D-SWE was not significantly different between PC and NPP, and evaluating the obtained elastic modulus itself is not useful in differentiation. However, the variability was significantly greater in PC than in NPP. Evaluating the range of elasticities will provide additional information in SWE, which may be useful in the diagnosis of PC.


Assuntos
Técnicas de Imagem por Elasticidade , Neoplasias Pancreáticas/diagnóstico , Idoso , Biomarcadores , Estudos de Casos e Controles , Análise de Dados , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/normas , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Imagem Multimodal/normas , Neoplasias Pancreáticas/metabolismo , Curva ROC , Reprodutibilidade dos Testes
12.
Curr Med Sci ; 41(1): 173-179, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33582923

RESUMO

The correlations between shear wave velocity (SWV) calculated from virtual touch tissue imaging quantification (VTIQ) technique and histological prognostic factors of invasive ductal carcinoma was investigated. A total of 76 breast tumors histologically confirmed as invasive ductal carcinomas were included in this study. SWV values were measured by VTIQ for each lesion preoperatively or prior to breast biopsy. The maximum values were recorded for statistical analysis. Medical records were reviewed to determine tumor size, histological grade, lymph node status and immunohistochemical results. Tumor subtypes were categorized as luminal A, luminal B, human epidermal growth factor receptor 2 (HER2) positive and triple negative. The correlations between SWV and histological prognostic factors were analyzed. It was found that tumor size showed positive association with SWV (r=0.465, P<0.001). Larger tumors had significantly higher SWV than smaller ones (P=0.001). Histological grade 1 tumors had significantly lower SWV values than those with higher histological grade (P=0.015). The Ki67 expression, tumor subtypes and lymph node status showed no statistically significant correlations with SWV, although triple negative tumors and lymph node-positive tumors showed higher SWV values. It was concluded that tumor size was significantly associated with SWV. Higher histological grade was associated with increased SWV. There was no statistically significant correlations between SWV and other histological prognostic factors.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Carcinoma Ductal/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/classificação , Neoplasias da Mama/patologia , Carcinoma Ductal/classificação , Carcinoma Ductal/patologia , Técnicas de Imagem por Elasticidade/normas , Feminino , Humanos , Metástase Linfática , Pessoa de Meia-Idade , Gradação de Tumores , Receptor ErbB-2/genética , Sensibilidade e Especificidade
13.
Medicine (Baltimore) ; 100(1): e24123, 2021 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-33429785

RESUMO

ABSTRACT: Elastosonography is a non-invasive diagnostic method to evaluate tissue stiffness. The aim of our study was to demonstrate the applicability and efficacy of elastosonography to differentiate benign vs malignant subpleural lung lesions compared to clinical, radiological and histological findings.We performed both strain and shear wave velocity (SWV) elastosonography on subpleural lung lesions. Moreover, we elaborated a composite score called "elasto index".Fourteen patients, 10 males and 4 females were recruited. On strain elastography, 9 lesions showed a hard pattern (type 3), 3 lesions showed an intermediate pattern (type 2), and 2 lesions a soft pattern (type 1). All lesions showed a mean SWV value of 4.46 ±â€Š2.37 m/second. The mean SWV for malignant lesions (n = 6) was 5.92 ±â€Š2.8 m/second. The mean SWV for benign lesions (n = 8) was 3.36 ±â€Š1.20 m/second. SWV shows an area under the curve (AUC) of 0.792, and the Youden index shows a value of 3.6 m/second. The ROC curve elaborated for the diagnosis of malignancy by strain elastography showed an AUC of 0.688. ROC curve for the diagnosis of malignancy by elasto index demonstrated an AUC of 0.802.SWV values obtained by ARFI elastosonographic method are higher in malignant lung lesions (mean SWV: 5.92 m/second) than in benign ones (mean SWV: 3.36); a composite score (elasto index) is characterized by better statistical significance for the differentiation of the lesions.


Assuntos
Técnicas de Imagem por Elasticidade/normas , Pulmão/diagnóstico por imagem , Neoplasias/diagnóstico , Idoso , Área Sob a Curva , Técnicas de Imagem por Elasticidade/métodos , Feminino , Humanos , Pulmão/anormalidades , Masculino , Pessoa de Meia-Idade , Neoplasias/diagnóstico por imagem , Curva ROC , Sensibilidade e Especificidade
14.
Phys Ther ; 101(1)2021 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-33508855

RESUMO

OBJECTIVE: Ultrasound elastography is an emerging diagnostic technology used to investigate the biomechanical properties of the musculoskeletal system. The purpose of this study was to systematically review the psychometric properties of ultrasound elastography techniques for evaluating muscle stiffness in people with neurological conditions. METHODS: A systematic search of MEDLINE, EMBASE, CINAHL, and Cochrane Library databases was performed in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Using software, reviewers independently screened citations for inclusion. Peer-reviewed studies that evaluated in vivo muscle stiffness in people with neurological conditions and reported relevant psychometric properties were considered for inclusion. Twenty-one articles were included for final review. Data relevant to measurement technique, site, and neurological condition were extracted. The Consensus-Based Standards for the Selection of Health Measurement Instruments checklist was used to rate the methodological quality of included studies. The level of evidence for specific measurement outcomes was determined using a best-evidence synthesis approach. RESULTS: Reliability varied across populations, ultrasound systems, and assessment conditions (ie, joint/body positions, active/passive muscle conditions, probe orientation), with most studies indicating moderate to good reliability (ICC = 0.5-0.9, n = 13). Meta-analysis results showed a good overall correlation across studies (r = 0.78, 95% confidence interval = 0.64-0.86), with no between-group difference based on population (Q1 = 0.00). Convergent validity was demonstrated by strong correlations between stiffness values and measures of spasticity (n = 5), functional motor recovery or impairment (n = 5), and grayscale or color histogram pixel intensities (n = 3). Discriminant or known-groups validity was also established for multiple studies and indicated either significant between-group differences in stiffness values (n = 12) or within-group differences between more and less affected limbs (n = 6). Responsiveness was observed in all intervention studies reporting posttreatment stiffness changes (n = 6). CONCLUSIONS: Overall, ultrasound elastography techniques showed moderate reliability in evaluating in vivo muscle stiffness, good convergent validity with relevant clinical assessments, and good divergent validity in discriminating tissue changes within and between groups. IMPACT: Ultrasound elastography has clinical utility in assessing muscle stiffness, monitoring its temporal changes, and measuring the response to intervention in people with neurological conditions.


Assuntos
Técnicas de Imagem por Elasticidade/normas , Doenças Musculares/diagnóstico por imagem , Doenças Musculares/fisiopatologia , Doenças do Sistema Nervoso/diagnóstico por imagem , Doenças do Sistema Nervoso/fisiopatologia , Avaliação da Deficiência , Humanos , Doenças Musculares/reabilitação , Doenças do Sistema Nervoso/reabilitação , Psicometria , Reprodutibilidade dos Testes
15.
Dig Dis Sci ; 66(4): 1297-1305, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32337667

RESUMO

BACKGROUND AND AIMS: The objective of our study was to determine the concordance rates of steatosis staging by controlled attenuation parameter (CAP) scores from transient elastography (TE) in comparison with liver histology in patients with chronic liver disease and to determine the optimal CAP cutoffs to predict the severity of steatosis and identify those with nonalcoholic steatohepatitis (NASH). METHODS: Patients (n = 217) who had both CAP scores and liver biopsy within a period of 90 days were retrospectively studied. Histology was graded in a blinded fashion by a single pathologist; steatosis was graded on a scale from 0 to 3. Nonalcoholic fatty liver disease activity scores (NAS) scores were calculated for all patients. Optimal CAP cut-points were selected by maximum Youden's index. RESULTS: Area under receiver operating characteristic curve (AUROC) for CAP (using cutoff value ≥ 278 dB/m) in differentiating steatosis 1-3 from 0 was 0.82 (95% CI 0.75-0.89), and 0.79 (95% CI 0.70-0.88) in differentiating steatosis 0-1 from 2 to 3 using CAP cutoff value ≥ 301 dB/m. With CAP cutoff value ≥ 301 dB/m, CAP identified NAS 3 or above with AUROC of 0.82 (95% CI 0.74-0.89). The AUROC for TE in differentiating fibrosis (cutoff 11.9 kPa) 3-4 from 0 to 2 was 0.85 (95% CI 0.77-0.92), and 0.84 (95% CI 0.74-0.93) in differentiating (cutoff 14.4 kPa) 4 from 0 to 3. CONCLUSIONS: Transient elastography is a good modality to accurately diagnose steatosis and NASH and can also differentiate advanced liver fibrosis from early stages.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/normas , Fígado Gorduroso/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Adulto , Idoso , Estudos de Coortes , Fígado Gorduroso/patologia , Fígado Gorduroso/cirurgia , Feminino , Humanos , Cirrose Hepática/patologia , Cirrose Hepática/cirurgia , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/patologia , Hepatopatia Gordurosa não Alcoólica/cirurgia , Estudos Retrospectivos
16.
Dig Dis Sci ; 66(6): 2084-2091, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-32648078

RESUMO

BACKGROUND AND AIMS: Several criteria have been described to noninvasively predict the presence of high-risk esophageal varices in patients with compensated advanced chronic liver disease (cACLD). However, a recent study showed that treatment with ß blockers could increase decompensation-free survival in patients with clinically significant portal hypertension, thereby making it important to predict the presence of any esophageal varices. We aimed to develop a simple scoring system to predict any esophageal varices. METHODS: We retrospectively reviewed patients who had vibration-controlled transient elastography (VCTE) at Cook County Hospital, Chicago, USA. Patients with cACLD and liver stiffness measurement (LSM) ≥ 10 kPa with esophagogastroduodenoscopy performed within one year of VCTE were analyzed. We generated a novel score to predict esophageal varices, using the beta coefficient of predictive variables. The score was validated in an external cohort at the University of Iowa Hospital, USA. RESULTS: There were 372 patients in the development cohort and 200 patients in the validation cohort. LSM, platelet count, and albumin were identified as predictors of esophageal varices and were included for generating the Cook County score as "platelet count * - 0.0155872 + VCTE score * 0.0387052 + albumin * - 0.8549209." The area under receiver operating curve for our score was 0.86 for any varices and 0.85 for high risk varices and avoided more endoscopies than the expanded Baveno VI criteria while maintaining a very low miss rate (negative predictive value > 99%). CONCLUSION: We propose a new, highly accurate, and easy-to-use scoring system to predict the presence of not only high-risk but any esophageal varices in patients with cACLD.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Doença Hepática Terminal/diagnóstico por imagem , Varizes Esofágicas e Gástricas/diagnóstico por imagem , Idoso , Técnicas de Imagem por Elasticidade/normas , Doença Hepática Terminal/fisiopatologia , Varizes Esofágicas e Gástricas/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos
17.
J Electromyogr Kinesiol ; 56: 102488, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33189075

RESUMO

The deep posterior cervical muscles (DPCM), specifically the semispinalis cervicis and cervical multifidus, are often impaired in patients with neck disorders and have been assessed by several imaging techniques. Prior ultrasound shear wave elastography (SWE) imaging and reliability assessments of the DPCM were performed utilizing similar positioning as assessments for the more superficial cervical extensors. Our objectives were to describe an SWE imaging technique for the DPCM, establish intra-rater reliability of DPCM SWE, and compare DPCM shear modulus during rest and submaximal contraction in both prone and seated positions in individuals without spinal pain. In sixteen participants, the DPCM was located using B-mode ultrasound, then muscle shear modulus was assessed via SWE at both rest and with contraction against a 2-kg resistance applied at the C2 spinous process. Within-day intra-rater reliability was moderate to good (ICC = 0.70-0.88). The DPCM were stiffer during contraction than at rest in the prone position (p = 0.002), and at rest in sitting versus at rest in prone (p = 0.003). Further research is needed to assess DPCM-specific SWE in symptomatic individuals and compare DPCM shear modulus to electromyography across contraction intensities.


Assuntos
Técnicas de Imagem por Elasticidade/normas , Contração Muscular/fisiologia , Músculos do Pescoço/diagnóstico por imagem , Músculos do Pescoço/fisiologia , Músculos Paraespinais/diagnóstico por imagem , Músculos Paraespinais/fisiologia , Adulto , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/fisiologia , Técnicas de Imagem por Elasticidade/métodos , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Ultrassonografia/métodos , Ultrassonografia/normas , Adulto Jovem
18.
J Hepatol ; 74(5): 1109-1116, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33307138

RESUMO

BACKGROUND: The Baveno VI consensus proposed a dual liver stiffness (LS) by transient elastography threshold of <10 and >15 kPa for excluding and diagnosing compensated advanced chronic liver disease (cACLD) in the absence of other clinical signs. Herein, we aimed to validate these criteria in a real-world multicentre study. METHODS: We included 5,648 patients (mean age 51 ± 13 years, 53% males) from 10 European liver centres who had a liver biopsy and LS measurement within 6 months. We included patients with chronic hepatitis C (n = 2,913, 52%), non-alcoholic fatty liver disease (NAFLD, n = 1,073, 19%), alcohol-related liver disease (ALD, n = 946, 17%) or chronic hepatitis B (n = 716, 13%). cACLD was defined as fibrosis stage ≥F3. RESULTS: Overall, 3,606 (66%) and 987 (18%) patients had LS <10 and >15 kPa, respectively, while cACLD was histologically confirmed in 1,772 (31%) patients. The cut-offs of <10 and >15 kPa showed 75% sensitivity and 96% specificity to exclude and diagnose cACLD, respectively. Examining the ROC curve, a more optimal dual cut-off at <7 and >12 kPa, with 91% sensitivity and 92% specificity for excluding and diagnosing cACLD (AUC 0.87; 95% CI 0.86-0.88; p <0.001) was derived. Specifically, for ALD and NAFLD, a low cut-off of 8 kPa can be used (sensitivity=93%). For the unclassified patients, we derived a risk model based on common patient characteristics with better discrimination than LS alone (AUC 0.74 vs. 0.69; p <0.001). CONCLUSIONS: Instead of the Baveno VI proposed <10 and >15 kPa dual cut-offs, we found that the <8 kPa (or <7 kPa for viral hepatitis) and >12 kPa dual cut-offs have better diagnostic accuracy in cACLD. LAY SUMMARY: The term compensated advanced chronic liver disease (cACLD) was introduced in 2015 to describe the spectrum of advanced fibrosis and cirrhosis in asymptomatic patients. It was also suggested that cACLD could be diagnosed or ruled out based on specific liver stiffness values, which can be non-invasively measured by transient elastography. Herein, we assessed the suggested cut-off values and identified alternative values that offered better overall accuracy for diagnosing or ruling out cACLD.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatite B Crônica , Hepatite Alcoólica , Cirrose Hepática , Fígado , Hepatopatia Gordurosa não Alcoólica , Biópsia , Precisão da Medição Dimensional , Elasticidade , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/normas , Técnicas de Imagem por Elasticidade/estatística & dados numéricos , Europa (Continente)/epidemiologia , Feminino , Hepatite B Crônica/complicações , Hepatite B Crônica/epidemiologia , Hepatite B Crônica/patologia , Hepatite Alcoólica/complicações , Hepatite Alcoólica/epidemiologia , Hepatite Alcoólica/patologia , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/diagnóstico , Cirrose Hepática/epidemiologia , Cirrose Hepática/etiologia , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/complicações , Hepatopatia Gordurosa não Alcoólica/epidemiologia , Hepatopatia Gordurosa não Alcoólica/patologia , Gravidade do Paciente , Sensibilidade e Especificidade
19.
PLoS One ; 15(11): e0242101, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33206696

RESUMO

BACKGROUND AND AIMS: Prison-based HCV treatment rates remain low due to multiple barriers, including accessing transient elastography for cirrhosis determination. The AST-to-platelet ratio index (APRI) and FIB-4 scores have excellent negative predictive value (NPV) in hospital cohorts to exclude cirrhosis. We investigated their performance in a large cohort of prisoners with HCV infection. METHODS: This was a retrospective cohort study of participants assessed by a prison-based hepatitis program. The sensitivity, specificity, NPV and positive predictive value (PPV) of APRI and FIB-4 for cirrhosis were then analysed, with transient elastography as the reference standard. The utility of age thresholds as a trigger for transient elastography was also explored. RESULTS: Data from 1007 prisoners were included. The median age was 41, 89% were male, and 12% had cirrhosis. An APRI cut-off of 1.0 and FIB-4 cut-off of 1.45 had NPVs for cirrhosis of 96.1% and 96.6%, respectively, and if used to triage prisoners for transient elastography, could reduce the need for this investigation by 71%. The PPVs of APRI and FIB-4 for cirrhosis at these cut-offs were low. Age ≤35 years alone had a NPV for cirrhosis of 96.5%. In those >35 years, the APRI cut-off of 1.0 alone had a high NPV >95%. CONCLUSION: APRI and FIB-4 scores can reliably exclude cirrhosis in prisoners and reduce requirement for transient elastography. This finding will simplify the cascade of care for prisoners living with hepatitis C.


Assuntos
Hepatite C/complicações , Cirrose Hepática/diagnóstico , Prisioneiros , Índice de Gravidade de Doença , Adulto , Algoritmos , Aspartato Aminotransferases/sangue , Técnicas de Imagem por Elasticidade/normas , Feminino , Humanos , Fígado/patologia , Cirrose Hepática/sangue , Cirrose Hepática/complicações , Masculino , Pessoa de Meia-Idade , Contagem de Plaquetas/normas
20.
Am J Trop Med Hyg ; 104(2): 712-717, 2020 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-33245042

RESUMO

Data on liver and spleen stiffness by 2-D shear wave elastography (2-D SWE) in hepatosplenic schistosomiasis (HES) remain scarce. We aimed to assess the correlation between single to multiple measurements of liver and spleen stiffness and to evaluate inter-hepatic lobe variability of liver stiffness measurement (LSM) using 2-D SWE in HES patients. Liver and spleen elastography were performed in HES patients in this cross-sectional study. A total of four stiffness measurements were performed in the right lobe (RL), left lobe (LL), and spleen. The correlation between the first measurement and the median of four measurements was assessed. Liver stiffness measurement of both hepatic lobes was compared. Twenty-six HES patients were included. Liver stiffness measurement was higher in the left than in the right hepatic lobe (17.9 kPa [11.3-92.0] versus 14.9 kPa [5.6-44.4]; P = 0.019). The first measurement was similar to the median of the four measurements for the RL (14.6 [5.6-60.8] versus 14.9 kPa [5.6-44.4]; P = 0.87), LL (17.4 [8.0-128.1] versus 17.9 kPa [11.3-92.0]; P = 0.54), and spleen (50.5 [10.0-157.0] versus 55.7 kPa [19.1-119.4]; P = 0.48). An excellent correlation between the first measurement and the median of four measurements for the RL (r = 0.93; P < 0.001), LL (r = 0.88; P < 0.001), and spleen (r = 0.89; P < 0.001) was observed. In HES, LSM of the LL seems to be higher than that of the right hepatic lobe. Considering the excellent correlation between the first measurement and the median of four measurements in both hepatic lobes and spleen, a single measurement would be sufficient to evaluate liver and splenic stiffness in patients with HES.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/normas , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/parasitologia , Fígado/diagnóstico por imagem , Esquistossomose/diagnóstico por imagem , Baço/diagnóstico por imagem , Estudos Transversais , Feminino , Humanos , Fígado/parasitologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Esquistossomose/complicações , Baço/parasitologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...