Resultados 1 - 20 de 287
Filtrar
1.
Sci Rep ; 14(1): 10637, 2024 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-38724569

RESUMO

Hadron therapy is an advanced radiation modality for treating cancer, which currently uses protons and carbon ions. Hadrons allow for a highly conformal dose distribution to the tumour, minimising the detrimental side-effects due to radiation received by healthy tissues. Treatment with hadrons requires sub-millimetre spatial resolution and high dosimetric accuracy. This paper discusses the design, fabrication and performance tests of a detector based on Gas Electron Multipliers (GEM) coupled to a matrix of thin-film transistors (TFT), with an active area of 60 × 80 mm2 and 200 ppi resolution. The experimental results show that this novel detector is able to detect low-energy (40 kVp X-rays), high-energy (6 MeV) photons used in conventional radiation therapy and protons and carbon ions of clinical energies used in hadron therapy. The GEM-TFT is a compact, fully scalable, radiation-hard detector that measures secondary electrons produced by the GEMs with sub-millimetre spatial resolution and a linear response for proton currents from 18 pA to 0.7 nA. Correcting known detector defects may aid in future studies on dose uniformity, LET dependence, and different gas mixture evaluation, improving the accuracy of QA in radiotherapy.


Assuntos
Radiometria , Radiometria/instrumentação , Radiometria/métodos , Humanos , Radioterapia/métodos , Radioterapia/normas , Radioterapia/instrumentação , Garantia da Qualidade dos Cuidados de Saúde , Elétrons , Dosagem Radioterapêutica , Neoplasias/radioterapia , Desenho de Equipamento , Terapia com Prótons/instrumentação , Terapia com Prótons/métodos
2.
Phys Med Biol ; 69(10)2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38640918

RESUMO

Objective. In this experimental work we compared the determination of absorbed dose to water using four ionization chambers (ICs), a PTW-34045 Advanced Markus, a PTW-34001 Roos, an IBA-PPC05 and a PTW-30012 Farmer, irradiated under the same conditions in one continuous- and in two pulsed-scanned proton beams.Approach. The ICs were positioned at 2 cm depth in a water phantom in four square-field single-energy scanned-proton beams with nominal energies between 80 and 220 MeV and in the middle of 10 × 10 × 10 cm3dose cubes centered at 10 cm or 12.5 cm depth in water. The water-equivalent thickness (WET) of the entrance window and the effective point of measurement was considered when positioning the plane parallel (PP) ICs and the cylindrical ICs, respectively. To reduce uncertainties, all ICs were calibrated at the same primary standards laboratory. We used the beam quality (kQ) correction factors for the ICs under investigation from IAEA TRS-398, the newly calculated Monte Carlo (MC) values and the anticipated IAEA TRS-398 updated recommendations.Main results. Dose differences among the four ICs ranged between 1.5% and 3.7% using both the TRS-398 and the newly recommendedkQvalues. The spread among the chambers is reduced with the newlykQvalues. The largest differences were observed between the rest of the ICs and the IBA-PPC05 IC, obtaining lower dose with the IBA-PPC05.Significance. We provide experimental data comparing different types of chambers in different proton beam qualities. The observed dose differences between the ICs appear to be related to inconsistencies in the determination of thekQvalues. For PP ICs, MC studies account for the physical thickness of the entrance window rather than the WET. The additional energy loss that the wall material invokes is not negligible for the IBA-PPC05 and might partially explain the lowkQvalues determined for this IC. To resolve this inconsistency and to benchmark MC values,kQvalues measured using calorimetry are needed.


Assuntos
Radiometria , Radiometria/instrumentação , Radiometria/métodos , Método de Monte Carlo , Terapia com Prótons/instrumentação , Prótons , Imagens de Fantasmas , Padrões de Referência , Incerteza , Água , Calibragem
3.
J Appl Clin Med Phys ; 25(5): e14349, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38551392

RESUMO

PURPOSE: Beam delivery latency in respiratory-gated particle therapy systems is a crucial issue to dose delivery accuracy. The aim of this study is to develop a multi-channel signal acquisition platform for investigating gating latencies occurring within RPM respiratory gating system (Varian, USA) and ProBeam proton treatment system (Varian, USA) individually. METHODS: The multi-channel signal acquisition platform consisted of several electronic components, including a string position sensor for target motion detection, a photodiode for proton beam sensing, an interfacing board for accessing the trigger signal between the respiratory gating system and the proton treatment system, a signal acquisition device for sampling and synchronizing signals from the aforementioned components, and a laptop for controlling the signal acquisition device and data storage. RPM system latencies were determined by comparing the expected gating phases extracted from the motion signal with the trigger signal's state turning points. ProBeam system latencies were assessed by comparing the state turning points of the trigger signal with the beam signal. The total beam delivery latencies were calculated as the sum of delays in the respiratory gating system and the cyclotron proton treatment system. During latency measurements, simulated sinusoidal motion were applied at different amplitudes and periods for complete beam delivery latency evaluation under different breathing patterns. Each breathing pattern was repeated 30 times for statistical analysis. RESULTS: The measured gating ON/OFF latencies in the RPM system were found to be 104.20 ± 13.64 ms and 113.60 ± 14.98 ms, respectively. The measured gating ON/OFF delays in the ProBeam system were 108.29 ± 0.85 ms and 1.20 ± 0.04 ms, respectively. The total beam ON/OFF latencies were determined to be 212.50 ± 13.64 ms and 114.80 ± 14.98 ms. CONCLUSION: With the developed multi-channel signal acquisition platform, it was able to investigate the gating lags happened in both the respiratory gating system and the proton treatment system. The resolution of the platform is enough to distinguish the delays at the millisecond time level. Both the respiratory gating system and the proton treatment system made contributions to gating latency. Both systems contributed nearly equally to the total beam ON latency, with approximately 100 ms. In contrast, the respiratory gating system was the dominant contributor to the total beam OFF latency.


Assuntos
Terapia com Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Terapia com Prótons/métodos , Terapia com Prótons/instrumentação , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Respiração , Neoplasias/radioterapia , Imagens de Fantasmas , Técnicas de Imagem de Sincronização Respiratória/métodos , Órgãos em Risco/efeitos da radiação
4.
Radiat Prot Dosimetry ; 199(15-16): 1937-1940, 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37819291

RESUMO

The radioluminescence (RL) emitted by LiMgPO4 detector under proton beam irradiation was investigated in real time at the radiotherapy facility in the Institute of Nuclear Physics Polish Academy of Sciences in Krakow. The facility uses protons accelerated by the AIC-144 isochronous cyclotron up to the energy of 60 MeV. The measurements of RL were carried out using a remote optical fiber device with a luminophore detector and photomultiplier located at opposite ends of the optical fiber. A thin slice of LiMgPO4 doped with Tm (1.2 mol%) crystal was exposed to the proton beam. The tested detector allowed for the measurement of proton beam current, flux fluence and determination of proton beam time structure parameters. The investigation of LiMgPO4 crystal showed its high sensitivity, fast reaction time to irradiation and possibility of application as the detector for control of proton beam parameters.


Assuntos
Ciclotrons , Terapia com Prótons , Controle de Qualidade , Dosagem Radioterapêutica , Radioterapia , Ciclotrons/instrumentação , Ciclotrons/normas , Luminescência , Polônia , Terapia com Prótons/instrumentação , Terapia com Prótons/normas , Prótons , Radioatividade , Radioterapia/normas , Dosagem Radioterapêutica/normas , Metais Leves
5.
Cancer Radiother ; 25(6-7): 554-564, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34272182

RESUMO

In the current spectrum of cancer treatments, despite high costs, a lack of robust evidence based on clinical outcomes or technical and radiobiological uncertainties, particle therapy and in particular proton therapy (PT) is rapidly growing. Despite proton therapy being more than fifty years old (first proposed by Wilson in 1946) and more than 220,000 patients having been treated with in 2020, many technological challenges remain and numerous new technical developments that must be integrated into existing systems. This article presents an overview of on-going technical developments and innovations that we felt were most important today, as well as those that have the potential to significantly shape the future of proton therapy. Indeed, efforts have been done continuously to improve the efficiency of a PT system, in terms of cost, technology and delivery technics, and a number of different developments pursued in the accelerator field will first be presented. Significant developments are also underway in terms of transport and spatial resolution achievable with pencil beam scanning, or conformation of the dose to the target: we will therefore discuss beam focusing and collimation issues which are important parameters for the development of these techniques, as well as proton arc therapy. State of the art and alternative approaches to adaptive PT and the future of adaptive PT will finally be reviewed. Through these overviews, we will finally see how advances in these different areas will allow the potential for robust dose shaping in proton therapy to be maximised, probably foreshadowing a future era of maturity for the PT technique.


Assuntos
Previsões , Neoplasias/radioterapia , Terapia com Prótons/tendências , Institutos de Câncer , Ciclotrons , Humanos , Análise de Ativação de Nêutrons , Tratamentos com Preservação do Órgão/instrumentação , Tratamentos com Preservação do Órgão/métodos , Órgãos em Risco , Terapia com Prótons/economia , Terapia com Prótons/instrumentação , Terapia com Prótons/métodos , Garantia da Qualidade dos Cuidados de Saúde , Radioterapia Guiada por Imagem/tendências , Síncrotrons
6.
Sci Rep ; 11(1): 15331, 2021 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-34321492

RESUMO

Proton therapy of prostate cancer (PCPT) was linked with increased levels of gastrointestinal toxicity in its early use compared to intensity-modulated radiation therapy (IMRT). The higher radiation dose to the rectum by proton beams is mainly due to anatomical variations. Here, we demonstrate an approach to monitor rectal radiation exposure in PCPT based on prompt gamma spectroscopy (PGS). Endorectal balloons (ERBs) are used to stabilize prostate movement during radiotherapy. These ERBs are usually filled with water. However, other water solutions containing elements with higher atomic numbers, such as silicon, may enable the use of PGS to monitor the radiation exposure of the rectum. Protons hitting silicon atoms emit prompt gamma rays with a specific energy of 1.78 MeV, which can be used to monitor whether the ERB is being hit. In a binary approach, we search the silicon energy peaks for every irradiated prostate region. We demonstrate this technique for both single-spot irradiation and real treatment plans. Real-time feedback based on the ERB being hit column-wise is feasible and would allow clinicians to decide whether to adapt or continue treatment. This technique may be extended to other cancer types and organs at risk, such as the oesophagus.


Assuntos
Neoplasias da Próstata/radioterapia , Terapia com Prótons/métodos , Lesões por Radiação/prevenção & controle , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Radioterapia de Intensidade Modulada/métodos , Enteroscopia de Balão/instrumentação , Enteroscopia de Balão/métodos , Raios gama , Humanos , Masculino , Próstata/patologia , Próstata/efeitos da radiação , Neoplasias da Próstata/patologia , Terapia com Prótons/instrumentação , Lesões por Radiação/diagnóstico , Radiometria/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/instrumentação , Radioterapia Conformacional/instrumentação , Radioterapia de Intensidade Modulada/instrumentação , Reto/efeitos da radiação , Silício/efeitos da radiação , Análise Espectral/métodos
7.
PLoS One ; 16(3): e0248300, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33690664

RESUMO

The Monte Carlo method was employed to simulate realistic treatment situations for photon and proton radiation therapy for a set of Oak Ridge National Laboratory (ORNL) pediatric phantoms for 15, 10, 5 and 1-year olds as well as newborns. Complete radiotherapy situations were simulated using the previously developed NRUrad input code for Monte Carlo N-Particle (MCNP) code package. Each pediatric phantom was irradiated at five different positions, namely, the testes, colon, liver, left lung and brain, and the doses in targeted organs (Dt) were determined using the track length estimate of energy. The dispersed photon and proton doses in non-targeted organs (Dd), namely, the skeleton, skin, brain, spine, left and right lungs were computed. The conversion coefficients (F = Dd/Dt) of the dispersed doses were used to study the dose dispersion in different non-targeted organs for phantoms for 15, 10, 5 and 1-year olds as well as newborns. In general, the F values were larger for younger patients. The F values for non-targeted organs for phantoms for 1-year olds and newborns were significantly larger compared to those for other phantoms. The dispersed doses from proton radiation therapy were also found to be significantly lower than those from conventional photon radiation therapy. For example, the largest F values for the brain were 65.6% and 0.206% of the dose delivered to the left lung (P4) for newborns during photon and proton radiation therapy, respectively. The present results demonstrated that dispersion of photons and generated electrons significantly affected the absorbed doses in non-targeted organs during pediatric photon therapy, and illustrated that proton therapy could in general bring benefits for treatment of pediatric cancer patients.


Assuntos
Modelos Teóricos , Imagens de Fantasmas , Terapia com Prótons , Doses de Radiação , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Terapia com Prótons/instrumentação , Terapia com Prótons/métodos
8.
Rev Sci Instrum ; 92(2): 024705, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33648062

RESUMO

We present the design for a rapid proton energy modulator with radiofrequency accelerator cavities, which can deliver the proton radiation dose to varied depth in human tissues much faster than traditional mechanical beam energy degraders. The proton energy modulator is designed as a multi-cell 1-m long accelerator working at 2.856 GHz. Each individual accelerator cavity is powered by a 400 kW compact klystron to provide an accelerating/decelerating gradient of 30 MV/m. The high gradient is enabled by the individual power coupling regime, which provides a high shunt impedance. Beam dynamics simulations were performed, showing that the energy modulator can provide ±30 MeV of beam energy change for a 150 MeV, 7 mm long (full length) proton bunch, and the total energy spread of 3 MeV is satisfactory to clinical needs. A prototype experiment of a single cell has been built and tested, and the low-power microwave measurement results agree very well with simulations. The energy modulator is optimized for the 150 MeV cyclotron proton beam, while this approach can work with different beam energies.


Assuntos
Terapia com Prótons/instrumentação , Desenho de Equipamento , Fatores de Tempo
9.
Phys Med Biol ; 66(5): 055018, 2021 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-33498040

RESUMO

Arc-therapy is a dose delivery technique regularly applied in photon radiation therapy, and is currently subject of great interest for proton therapy as well. In this technique, proton beams are aimed at a tumor from different continuous ranges of incident directions (so called 'arcs'). This technique can potentially yield a better dose conformity around the tumor and a very low dose in the surrounding healthy tissue. Currently, proton-arc therapy is performed by rotating a proton gantry around the patient, adapting the normally used dose-delivery method to the arc-specific motion of the gantry. Here we present first results from a feasibility study of the conceptual design of a new static fast beam delivery device/system for proton-arc therapy, which could be used instead of a gantry. In this novel concept, the incident angle of proton beams can be set rapidly by only changing field strengths of small magnets. This device eliminates the motion of the heavy gantry and related hardware. Therefore, a reduction of the total treatment time is expected. In the feasibility study presented here, we concentrate on the concept of the beam transport. Based on several simple, but realistic assumptions and approximations, proton tracking calculations were performed in a 3D magnetic field map, to calculate the beam transport in this device and to investigate and address several beam-optics challenges. We propose and simulate corresponding solutions and discuss their outcomes. To enable the implementation of some usually applied techniques in proton therapy, such as pencil beam scanning, energy modulation and beam shaping, we present and discuss our proposals. Here we present the concept of a new idea to perform fast proton arc-scanning and we report on first results of a feasibility study. Based on these results, we propose several options and next steps in the design.


Assuntos
Terapia com Prótons/instrumentação , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Fatores de Tempo
10.
Phys Med Biol ; 66(4): 045003, 2021 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-33296888

RESUMO

The presence of artificial implants complicates the delivery of proton therapy due to inaccurate characterization of both the implant and the surrounding tissues. In this work, we describe a method to characterize implant and human tissue mimicking materials in terms of relative stopping power (RSP) using a novel proton counting detector. Each proton is tracked by directly measuring the deposited energy along the proton track using a fast, pixelated spectral detector AdvaPIX-TPX3 (TPX3). We considered three scenarios to characterize the RSPs. First, in-air measurements were made in the presence of metal rods (Al, Ti and CoCr) and bone. Then, measurements of energy perturbations in the presence of metal implants and bone in an anthropomorphic phantom were performed. Finally, sampling of cumulative stopping power (CSP) of the phantom were made at different locations of the anthropomorphic phantom. CSP and RSP information were extracted from energy spectra at each beam path. To quantify the RSP of metal rods we used the shift in the most probable energy (MPE) of CSP from the reference CSP without a rod. Overall, the RSPs were determined as 1.48, 2.06, 3.08, and 5.53 from in-air measurements; 1.44, 1.97, 2.98, and 5.44 from in-phantom measurements, for bone, Al, Ti and CoCr, respectively. Additionally, we sampled CSP for multiple paths of the anthropomorphic phantom ranging from 18.63 to 25.23 cm deriving RSP of soft tissues and bones in agreement within 1.6% of TOPAS simulations. Using minimum error of these multiple CSP, optimal mass densities were derived for soft tissue and bone and they are within 1% of vendor-provided nominal densities. The preliminary data obtained indicates the proposed novel method can be used for the validation of material and density maps, required by proton Monte Carlo Dose calculation, provided by competing multi-energy computed tomography and metal artifact reduction techniques.


Assuntos
Método de Monte Carlo , Imagens de Fantasmas , Próteses e Implantes , Terapia com Prótons/instrumentação , Humanos
11.
Phys Med Biol ; 66(3): 035012, 2021 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-33202399

RESUMO

The lowest possible energy of proton scanning beam in cyclotron proton therapy facilities is typically between 60 and 100 MeV. Treatment of superficial lesions requires a pre-absorber to deliver doses to shallower volumes. In most of the cases a range shifter (RS) is used, but as an alternative solution, a patient-specific 3D printed proton beam compensator (BC) can be applied. A BC enables further reduction of the air gap and consequently reduction of beam scattering. Such pre-absorbers are additional sources of secondary radiation. The aim of this work was the comparison of RS and BC with respect to out-of-field doses for a simulated treatment of superficial paediatric brain tumours. EURADOS WG9 performed comparative measurements of scattered radiation in the Proteus C-235 IBA facility (Cyclotron Centre Bronowice at the Institute of Nuclear Physics, CCB IFJ PAN, Kraków, Poland) using two anthropomorphic phantoms-5 and 10 yr old-for a superficial target in the brain. Both active detectors located inside the therapy room, and passive detectors placed inside the phantoms were used. Measurements were supplemented by Monte Carlo simulation of the radiation transport. For the applied 3D printed pre-absorbers, out-of-field doses from both secondary photons and neutrons were lower than for RS. Measurements with active environmental dosimeters at five positions inside the therapy room indicated that the RS/BC ratio of the out-of-field dose was also higher than one, with a maximum of 1.7. Photon dose inside phantoms leads to higher out-of-field doses for RS than BC to almost all organs with the highest RS/BC ratio 12.5 and 13.2 for breasts for 5 and 10 yr old phantoms, respectively. For organs closest to the isocentre such as the thyroid, neutron doses were lower for BC than RS due to neutrons moderation in the target volume, but for more distant organs like bladder-conversely-lower doses for RS than BC were observed. The use of 3D printed BC as the pre-absorber placed in the near vicinity of patient in the treatment of superficial tumours does not result in the increase of secondary radiation compared to the treatment with RS, placed far from the patient.


Assuntos
Impressão Tridimensional , Terapia com Prótons/instrumentação , Doses de Radiação , Neoplasias Encefálicas/radioterapia , Criança , Simulação por Computador , Humanos , Método de Monte Carlo , Nêutrons , Imagens de Fantasmas , Dosagem Radioterapêutica
12.
Phys Med Biol ; 66(5): 055005, 2021 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-33171445

RESUMO

Prompt gamma (PG) imaging is widely investigated as one of the most promising methods for proton range verification in proton therapy. The performance of this technique is affected by several factors like tissue heterogeneity, number of protons in the considered pencil beam and the detection device. Our previous work proposed a new treatment planning concept which boosts the number of protons of a few PG monitoring-friendly pencil beams (PBs), selected on the basis of two proposed indicators quantifying the conformity between the dose and PG at the emission level, above the desired detectability threshold. To further explore this method at the detection level, in this work we investigated the response of a knife-edge slit PG camera which was deployed in the first clinical application of PG to proton therapy monitoring. The REGistration Graphical User Interface (REGGUI) is employed to simulate the PG emission, PG detection as well as the corresponding dose distribution. As the PG signal detected by this kind of PG camera is sensitive to the relative position of the camera and PG signal falloff, we optimized our PB selection method for this camera by introducing a new camera position indicator identifying whether the expected falloff of the PG signal is centered in the field of view of the camera or not. Our camera-adapted PB selection method is investigated using computed tomography (CT) scans at two different treatment time points of a head and neck, and a prostate cancer patient under scenarios considering different statistics level. The results show that a precision of 0.8 mm for PG falloff identification can be achieved when a PB has more than 2 × 108 primary protons. Except for one case due to unpredictable and comparably large anatomical changes, the PG signals of most of the PBs recommended by all our indicators are observed to be reliable for proton range verification with deviations between the inter-fractional shift of proton range (as deduced from the PB dose distribution) and the detected PG signal within 2.0 mm. In contrast, a shift difference up to 9.6 mm has been observed for the rejected PBs. The magnitude of the proton range shift due to the inter-fractional anatomical changes is observed to be up to 23 mm. The proposed indicators are shown to be valuable for identifying and recommending reliable PBs to create new PG monitoring-friendly TPs. Comparison between our PB boosting method and the alternative PB aggregation, which combines the signal of nearby PBs to reach the desired counting statistics, is also discussed.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Processamento de Imagem Assistida por Computador/métodos , Neoplasias da Próstata/radioterapia , Terapia com Prótons/instrumentação , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Câmaras gama , Raios gama , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Masculino , Método de Monte Carlo , Neoplasias da Próstata/patologia
13.
Sci Rep ; 10(1): 20385, 2020 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-33230208

RESUMO

In contrast to conventional X-ray therapy, proton beam therapy (PBT) can confine radiation doses to tumours because of the presence of the Bragg peak. However, the precision of the treatment is currently limited by the uncertainty in the beam range. Recently, a unique range verification methodology has been proposed based on simulation studies that exploit spherical ionoacoustic waves with resonant frequency (SPIREs). SPIREs are emitted from spherical gold markers in tumours initially introduced for accurate patient positioning when the proton beam is injected. These waves have a remarkable property: their amplitude is linearly correlated with the residual beam range at the marker position. Here, we present proof-of-principle experiments using short-pulsed proton beams at the clinical dose to demonstrate the feasibility of using SPIREs for beam-range verification with submillimetre accuracy. These results should substantially contribute to reducing the range uncertainty in future PBT applications.


Assuntos
Ouro/efeitos da radiação , Imagens de Fantasmas , Terapia com Prótons/métodos , Prótons , Ouro/química , Humanos , Método de Monte Carlo , Terapia com Prótons/instrumentação , Dosagem Radioterapêutica , Som , Água/química
14.
Phys Med Biol ; 65(24): 245045, 2020 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-33157544

RESUMO

A deeper understanding of biological mechanisms to promote more efficient treatment strategies in proton therapy demands advances in preclinical radiation research. However this is often limited by insufficient availability of adequate infrastructures for precision image guided small animal proton irradiation. The project SIRMIO aims at filling this gap by developing a portable image-guided research platform for small animal irradiation, to be used at clinical facilities and allowing for a precision similar to a clinical treatment, when scaled down to the small animal size. This work investigates the achievable dosimetric properties of different lowest energy clinical proton therapy beams, manipulated by a dedicated portable beamline including active focusing after initial beam energy degradation and collimation. By measuring the lateral beam size in air close to the beam nozzle exit and the laterally integrated depth dose in water, an analytical beam model based on the beam parameters of the clinical beam at the Rinecker Proton Therapy Center was created for the lowest available clinical beam energy. The same approach was then applied to estimate the lowest energy beam model of different proton therapy facilities, Paul Scherrer Institute, Centre Antoine Lacassagne, Trento Proton Therapy Centre and the Danish Centre for Particle Therapy, based on their available beam commissioning data. This comparison indicated similar beam properties for all investigated sites, with emittance values of a few tens of mm·mrad. Finally, starting from these beam models, we simulated propagation through a novel beamline designed to manipulate the beam energy and size for precise small animal irradiation, and evaluated the resulting dosimetric properties in water. For all investigated initial clinical beams, similar dosimetric results suitable for small animal irradiation were found. This work supports the feasibility of the proposed SIRMIO beamline, promising suitable beam characteristics to allow for precise preclinical irradiation at clinical treatment facilities.


Assuntos
Terapia com Prótons/instrumentação , Animais , Estudos de Viabilidade , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem , Síncrotrons
15.
Phys Med Biol ; 65(24): 245027, 2020 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-33120374

RESUMO

The IRIS group at IFIC Valencia is developing a three-layer Compton camera for treatment monitoring in proton therapy. The system is composed of three detector planes, each made of a [Formula: see text] monolithic crystal coupled to a SiPM array. Having obtained successful results with the first prototype (MACACO) that demonstrated the feasibility of the proposed technology, a second prototype (MACACO II) with improved performance has been developed, and is the subject of this work. The new system has an enhanced detector energy resolution which translates into a higher spatial resolution of the telescope. The image reconstruction method has also been improved with an accurate model of the sensitivity matrix. The device has been tested with high energy photons at the National Accelerator Centre (CNA, Seville). The tests involved a proton beam of 18 MeV impinging on a graphite target, to produce 4.4 MeV photons. Data were taken at different system positions of the telescope with the first detector at 65 and 160 mm from the target, and at different beam intensities. The measurements allowed successful reconstruction of the photon emission distribution at two target positions separated by 5 mm in different telescope configurations. This result was obtained both with data recorded in the first and second telescope planes (two interaction events) and, for the first time in beam experiments, with data recorded in the three planes (three interaction events).


Assuntos
Fótons , Terapia com Prótons/métodos , Estudos de Viabilidade , Humanos , Terapia com Prótons/instrumentação , Telescópios
16.
Sci Rep ; 10(1): 15325, 2020 09 18.
Artigo em Inglês | MEDLINE | ID: mdl-32948790

RESUMO

Tumour tracking is an advanced radiotherapy technique for precise treatment of tumours subject to organ motion. In this work, we addressed crucial aspects of dose delivery for its realisation in pencil beam scanning proton therapy, exploring the momentum acceptance and global achromaticity of a Gantry beamline to perform continuous energy regulation with a standard upstream degrader. This novel approach is validated on simulation data from three geometric phantoms of increasing complexity and one liver cancer patient using 4D dose calculations. Results from a standard high-to-low beamline ramping scheme were compared to alternative energy meandering schemes including combinations with rescanning. Target coverage and dose conformity were generally well recovered with tumour tracking even though for particularly small targets, large variations are reported for the different approaches. Meandering in energy while rescanning has a positive impact on target homogeneity and similarly, hot spots outside the targets are mitigated with a relatively fast convergence rate for most tracking scenarios, halving the volume of hot spots after as little as 3 rescans. This work investigates the yet unexplored potential of having a large momentum acceptance in medical beam line, and provides an alternative to take tumour tracking with particle therapy closer to clinical translation.


Assuntos
Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Simulação por Computador , Humanos , Neoplasias Hepáticas/radioterapia , Imagens de Fantasmas , Terapia com Prótons/instrumentação , Dosagem Radioterapêutica
17.
Phys Med Biol ; 65(21): 215030, 2020 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-32736371

RESUMO

The proof of concept of a new device, capable of determining in a few seconds the energy of clinical proton beams by measuring the time of flight (ToF) of protons, is presented. The prototype consists of two thin ultra fast silicon detector (UFSD) pads, aligned along the beam direction in a telescope configuration and readout by a digitizer. The method developed for extracting the energy at the isocenter from the measured ToF, validated by Monte Carlo simulations, and the procedure used to calibrate the system are also presented and discussed in detail. The prototype was tested at the Centro Nazionale di Adroterapia Oncologica (CNAO, Pavia, Italy), at several beam energies, covering the entire clinical range, and using different distances between the sensors. The measured beam energies were benchmarked against the nominal CNAO energy values, obtained during the commissioning of the centre from the measured ranges in water. Deviations of few hundreds of keV have been achieved for all considered proton beam energies for distances between the two sensors larger than 60 cm, indicating a sensitivity to the corresponding beam range in water smaller than the clinical tolerance of 1 mm. Moreover, few seconds of irradiation were necessary to collect the required statistics. These preliminary results indicate that a telescope of UFSDs could achieve in a short time the accuracy required for the clinical application and therefore encourage further investigations towards the improvement and the optimization of the present prototype.


Assuntos
Terapia com Prótons/métodos , Estudos de Viabilidade , Humanos , Método de Monte Carlo , Terapia com Prótons/instrumentação , Planejamento da Radioterapia Assistida por Computador
18.
Sci Rep ; 10(1): 11368, 2020 07 09.
Artigo em Inglês | MEDLINE | ID: mdl-32647361

RESUMO

Proton minibeams (MBs) comprised of parallel planar beamlets were evaluated for their ability to spare healthy brain compared to proton broad beams (BBs). Juvenile mice were given partial brain irradiation of 10 or 30 Gy integral dose using 100 MeV protons configured either as BBs or arrays of 0.3-mm planar MBs spaced 1.0 mm apart on center. Neurologic toxicity was evaluated during an 8-month surveillance: no overt constitutional or neurologic dysfunction was noted for any study animals. Less acute epilation was observed in MB than BB mice. Persistent chronic inflammation was noted along the entire BB path in BB mice whereas inflammation was confined to just within the MB peak regions in MB mice. The potential neurologic sparing, possibly via reduced volume of chronic inflammation, offers a compelling rationale for clinical advancement of this proton technique.


Assuntos
Neoplasias Encefálicas/radioterapia , Encéfalo/efeitos da radiação , Tratamentos com Preservação do Órgão/efeitos adversos , Terapia com Prótons/efeitos adversos , Lesões Experimentais por Radiação/diagnóstico , Animais , Técnicas de Observação do Comportamento , Comportamento Animal/efeitos da radiação , Encéfalo/patologia , Encéfalo/fisiopatologia , Cognição/fisiologia , Cognição/efeitos da radiação , Humanos , Masculino , Camundongos , Testes Neuropsicológicos , Tratamentos com Preservação do Órgão/instrumentação , Tratamentos com Preservação do Órgão/métodos , Projetos Piloto , Terapia com Prótons/instrumentação , Terapia com Prótons/métodos , Lesões Experimentais por Radiação/etiologia , Lesões Experimentais por Radiação/patologia , Lesões Experimentais por Radiação/fisiopatologia , Dosagem Radioterapêutica
19.
Rev Sci Instrum ; 91(5): 054102, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32486707

RESUMO

A single crystal chemical vapor deposition diamond-based microdosimeter prototype featuring an array of micro-sensitive volumes (µSVs) and surrounded by a so-called guard ring (GR) electrode has been fabricated using various microfabrication techniques available at Diamond Sensors Laboratory of CEA, Saclay. The GR microdosimeter was irradiated by a raster scanning method with 2 MeV proton microbeams. The charge transport properties of the GR sensor were determined with sub-micron spatial resolution by measuring the charge collection efficiency (CCE), the µSV geometry, and the pulse-height spectra. The response of the microdosimeter showed a well-defined and homogeneously active µSV. Appropriate biasing of the µSV structures led toward a full CCE for protons with lineal energies of ∼46 keV/µm. This shows the GR microdosimeter's great potential for applications in microdosimetry in clinical beam conditions.


Assuntos
Diamante , Terapia com Prótons/instrumentação , Radiometria/instrumentação , Eletrodos , Volatilização
20.
Radiat Oncol ; 15(1): 129, 2020 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-32471500

RESUMO

BACKGROUND: The targeting accuracy of proton therapy (PT) for moving soft-tissue tumours is expected to greatly improve by real-time magnetic resonance imaging (MRI) guidance. The integration of MRI and PT at the treatment isocenter would offer the opportunity of combining the unparalleled soft-tissue contrast and real-time imaging capabilities of MRI with the most conformal dose distribution and best dose steering capability provided by modern PT. However, hybrid systems for MR-integrated PT (MRiPT) have not been realized so far due to a number of hitherto open technological challenges. In recent years, various research groups have started addressing these challenges and exploring the technical feasibility and clinical potential of MRiPT. The aim of this contribution is to review the different aspects of MRiPT, to report on the status quo and to identify important future research topics. METHODS: Four aspects currently under study and their future directions are discussed: modelling and experimental investigations of electromagnetic interactions between the MRI and PT systems, integration of MRiPT workflows in clinical facilities, proton dose calculation algorithms in magnetic fields, and MRI-only based proton treatment planning approaches. CONCLUSIONS: Although MRiPT is still in its infancy, significant progress on all four aspects has been made, showing promising results that justify further efforts for research and development to be undertaken. First non-clinical research solutions have recently been realized and are being thoroughly characterized. The prospect that first prototype MRiPT systems for clinical use will likely exist within the next 5 to 10 years seems realistic, but requires significant work to be performed by collaborative efforts of research groups and industrial partners.


Assuntos
Imageamento por Ressonância Magnética/métodos , Terapia com Prótons/métodos , Radioterapia Guiada por Imagem/métodos , Humanos , Campos Magnéticos , Imageamento por Ressonância Magnética/instrumentação , Sistemas On-Line , Terapia com Prótons/instrumentação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/instrumentação , Fluxo de Trabalho