Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.433
Filtrar
1.
Sci Rep ; 14(1): 10449, 2024 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-38714775

RESUMO

The body temperature of infants at equilibrium with their surroundings is balanced between heat production from metabolism and the transfer of heat to the environment. Total heat production is related to body size, which is closely related to metabolic rate and oxygen consumption. Body temperature control is a crucial aspect of neonatal medicine but we have often struggled with temperature measures. Contactless infrared thermography (IRT) is useful for vulnerable neonates and may be able to assess their spontaneous thermal metabolism. The present study focused on heat oscillations and their cause. IRT was used to measure the skin temperature every 15 s of neonates in an incubator. We analyzed the thermal data of 27 neonates (32 measurements), calculated the average temperature within specified regions, and extracted two frequency components-Components A and B-using the Savitzky-Golay method. Furthermore, we derived an equation describing the cycle-named cycle T-for maintaining body temperature according to body weight. A positive correlation was observed between cycle T and Component B (median [IQR]: 368 [300-506] s). This study sheds light on the physiological thermoregulatory function of newborns and will lead to improved temperature management methods for newborns, particularly premature, low-birth-weight infants.


Assuntos
Regulação da Temperatura Corporal , Termografia , Humanos , Recém-Nascido , Termografia/métodos , Regulação da Temperatura Corporal/fisiologia , Feminino , Masculino , Monitorização Fisiológica/métodos , Temperatura Corporal/fisiologia , Temperatura Cutânea/fisiologia
2.
PLoS One ; 19(5): e0300373, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38696403

RESUMO

Captive and domestic animals are often required to engage in physical activity initiated or organised by humans, which may impact their body temperature, with consequences for their health and welfare. This is a particular concern for animals such as elephants that face thermoregulatory challenges because of their body size and physiology. Using infrared thermography, we measured changes in skin temperature associated with two types of physical activity in ten female Asian elephants (Elephas maximus) at an eco-tourism lodge in Nepal. Six elephants took part in an activity relatively unfamiliar to the elephants-a polo tournament-and four participated in more familiar ecotourism activities. We recorded skin temperatures for four body regions affected by the activities, as well as an average skin temperature. Temperature change was used as the response variable in the analysis and calculated as the difference in elephant temperature before and after activity. We found no significant differences in temperature change between the elephants in the polo-playing group and those from the non-polo playing group. However, for both groups, when comparing the average skin body temperature and several different body regions, we found significant differences in skin temperature change before and after activity. The ear pinna was the most impacted region and was significantly different to all other body regions. This result highlights the importance of this region in thermoregulation for elephants during physical activity. However, as we found no differences between the average body temperatures of the polo and non-polo playing groups, we suggest that thermoregulatory mechanisms can counteract the effects of both physical activities the elephants engaged in.


Assuntos
Elefantes , Temperatura Cutânea , Animais , Elefantes/fisiologia , Feminino , Temperatura Cutânea/fisiologia , Condicionamento Físico Animal/fisiologia , Temperatura Corporal/fisiologia , Regulação da Temperatura Corporal/fisiologia , Termografia/métodos
3.
Adv Rheumatol ; 64(1): 36, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702760

RESUMO

BACKGROUND: While ultrasound and MRI are both superior to clinical examination in the detection of joint inflammation, there is presently a lack of data whether thermography may be similarly useful in the assessment of joint inflammation in patients with RA. Our study aims to evaluate the use of thermography in detecting subclinical joint inflammation at clinically quiescent (non-tender and non-swollen) metacarpophalangeal joints (MCPJs) in patients with rheumatoid arthritis (RA). The outcomes from thermography in our study will be compared with ultrasonography (which is a more established imaging tool used for joint inflammation assessment in RA). METHODS: The minimum (Tmin), average (Tavg) and maximum (Tmax) temperatures at the 10 MCPJs of each patient were summed to obtain the Total Tmin, Total Tavg and Total Tmax, respectively. Ultrasound grey-scale (GS) and power Doppler (PD) joint inflammation (scored semi-quantitatively, 0-3) at the 10 MCPJs were summed up to derive the respective TGS and TPD scores per patient. Pearson's correlation and simple linear regression were respectively used to assess correlation and characterize relationships between thermographic parameters (Total Tmin, Total Tavg and Total Tmax) and ultrasound imaging parameters (TGS, TPD and the number of joint(s) with PD ≥ 1 or GS ≥ 2). RESULTS: In this cross-sectional study, 420 clinically non-swollen and non-tender MCPJs from 42 RA patients were examined. All thermographic parameters (Total Tmin, Total Tavg and Total Tmax) correlated significantly (P-values ranging from 0.001 to 0.0012) with TGS score (correlation coefficient ranging from 0.421 to 0.430), TPD score (correlation coefficient ranging from 0.383 to 0.424), and the number of joint(s) with PD ≥ 1 or GS ≥ 2 (correlation coefficient ranging from 0.447 to 0.465). Similarly, simple linear regression demonstrated a statistically significant relationship (P-values ranging from 0.001 to 0.005) between all thermographic parameters (Total Tmin, Total Tavg and Total Tmax) and ultrasound imaging parameters (TPD and TGS). CONCLUSION: For the first time, thermographic temperatures were shown to correlate with ultrasound-detected joint inflammation at clinically quiescent MCPJs. The use of thermography in the detection of subclinical joint inflammation in RA appears promising and warrants further investigation.


Assuntos
Artrite Reumatoide , Articulação Metacarpofalângica , Termografia , Humanos , Artrite Reumatoide/diagnóstico por imagem , Artrite Reumatoide/complicações , Termografia/métodos , Articulação Metacarpofalângica/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Ultrassonografia Doppler/métodos , Ultrassonografia , Inflamação/diagnóstico por imagem , Adulto , Idoso
4.
Zhongguo Zhen Jiu ; 44(4): 423-427, 2024 Apr 12.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-38621730

RESUMO

OBJECTIVES: To observe the body surface temperature of the lumbosacral region and relevant back-shu points in patients with lumbar disc herniation (LDH) induced low back pain utilizing infrared thermography, and to explore the functional attribute changes of acupoints under pathological conditions. METHODS: A total of 50 patients with LDH induced low back pain were included as the observation group, and 45 healthy subjects were included as the control group. Using infrared thermography, the body surface temperature of the lumbosacral region and bilateral Sanjiaoshu (BL 22), Shenshu (BL 23), Qihaishu (BL 24), Dachangshu (BL 25), Guanyuanshu (BL 26), Xiaochangshu (BL 27), and Pangguangshu (BL 28) was measured in both groups. The temperature difference values between the bilateral lumbosacral regions and back-shu points of the two groups were calculated. Additionally, the body surface temperature of the affected and healthy sides of the lumbosacral region and relevant back-shu points was compared in the observation group. RESULTS: Compared with the control group, the body surface temperature of the lumbosacral region and the bilateral temperature difference values of the lumbosacral regions were increased in the observation group (P<0.001). The body surface temperature difference values of bilateral Shenshu (BL 23), Qihaishu (BL 24), Dachangshu (BL 25), Guanyuanshu (BL 26) and Xiaochangshu (BL 27) in the observation group were higher than those in the control group (P<0.05, P<0.01, P<0.001). In the observation group, the body surface temperature of the affected side of the lumbosacral region as well as Shenshu (BL 23) and Dachangshu (BL 25) was elevated compared with that of healthy side (P<0.001). CONCLUSIONS: The patients with LDH induced low back pain have imbalanced and asymmetrical distribution of body surface temperature in the lumbosacral region and related back-shu points, Shenshu (BL 23) and Dachangshu (BL 25) have the relative specificity.


Assuntos
Deslocamento do Disco Intervertebral , Dor Lombar , Humanos , Deslocamento do Disco Intervertebral/terapia , Dor Lombar/etiologia , Dor Lombar/terapia , Região Lombossacral , Temperatura , Termografia , Pontos de Acupuntura
5.
Sensors (Basel) ; 24(8)2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38676064

RESUMO

Over the past 20 years, the high prevalence of diabetes has become a global public health problem. BACKGROUND: The objective of this study was to develop a non-invasive screening method for diabetes which will enable the detection of the disease at an early stage. METHODS: This study included 63 adult patients of both sexes: 30 patients with type 2 diabetes (t2DM) and 33 healthy volunteers. The temperature distribution on the tongue's dorsum and apex surface was studied in patients after a mouth-cooling procedure had been introduced. The study used an FLIR T540 thermal imaging camera. An analysis of the correlation between the ∆T values of the tongue dorsum and apex and the glycated hemoglobin (HbA1c) level was performed. RESULTS: The median of the average dorsum temperature measured 10 min after mouth rinsing was almost 0.8 [°C] lower than for healthy individuals. Also, studies showed a positive average correlation with a Pearson coefficient of r = 0.46 between the HbA1c level and the ∆T of the tongue dorsum. CONCLUSIONS: Tongue temperature measured using the IRT showed a correlation with standard biochemical parameters; it may also differentiate patients and constitute a specific screening method for patients with t2DM.


Assuntos
Diabetes Mellitus Tipo 2 , Hemoglobinas Glicadas , Língua , Humanos , Diabetes Mellitus Tipo 2/diagnóstico , Masculino , Língua/diagnóstico por imagem , Língua/patologia , Feminino , Pessoa de Meia-Idade , Hemoglobinas Glicadas/análise , Adulto , Termografia/métodos , Idoso
6.
J Int Soc Sports Nutr ; 21(1): 2346563, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38676933

RESUMO

BACKGROUND: Due to the increase in global temperature, it is necessary to investigate solutions so that athletes competing in hot conditions can perform in optimal conditions avoiding loss of performance and health problems. Therefore, this study aims to evaluate the effect of pre-exercise glycerol supplementation during a rectangular test at ambient temperature mid (28.2ºC) on dehydration variables in international race walkers. METHODS: Eight international male race walkers (age: 28.0 years (4.4); weight: 65.6 kg (6.6); height: 180.0 cm (5.0); fat mass: 6.72% (0.66); muscle mass: 33.3 kg (3.3); VO2MAX: 66.5 ml · kg-1·min-1 (1.9)) completed this randomized crossover design clinical trial. Subjects underwent two interventions: they consumed placebo (n = 8) and glycerol (n = 8) acutely, before a rectangular test where dehydration, RPE, metabolic, kinematic, and thermographic variables were analyzed before, during and after the test. RESULTS: After the intervention, significant differences were found between groups in body mass in favor of the placebo (Placebo: -2.23 kg vs Glycerol: -2.48 kg; p = 0.033). For other variables, no significant differences were found. CONCLUSION: Therefore, pre-exercise glycerol supplementation was not able to improve any dehydration, metabolic, kinematic, or thermographic variables during a rectangular test at temperature mid in international race walkers. Possibly, a higher environmental temperature could have generated a higher metabolic and thermoregulatory stress, generating differences between groups like other previous scientific evidence.


Assuntos
Estudos Cross-Over , Desidratação , Suplementos Nutricionais , Glicerol , Caminhada , Humanos , Masculino , Glicerol/administração & dosagem , Glicerol/sangue , Adulto , Caminhada/fisiologia , Fenômenos Biomecânicos , Termografia , Fenômenos Fisiológicos da Nutrição Esportiva , Adulto Jovem , Consumo de Oxigênio/efeitos dos fármacos , Temperatura Alta , Desempenho Atlético/fisiologia
7.
Methods Mol Biol ; 2790: 317-332, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38649578

RESUMO

Infrared thermography offers a rapid, noninvasive method for measuring plant temperature, which provides a proxy for stomatal conductance and plant water status and can therefore be used as an index for plant stress. Thermal imaging can provide an efficient method for high-throughput screening of large numbers of plants. This chapter provides guidelines for using thermal imaging equipment and illustrative methodologies, coupled with essential considerations, to access plant physiological processes.


Assuntos
Raios Infravermelhos , Fenótipo , Termografia , Termografia/métodos , Plantas , Ensaios de Triagem em Larga Escala/métodos , Fenômenos Fisiológicos Vegetais , Temperatura , Estômatos de Plantas/fisiologia
8.
J Wound Care ; 33(Sup4a): cxviii-cxxix, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38588060

RESUMO

OBJECTIVE: Accurate assessment of burn depth and burn wound healing potential is essential to determine early treatments. Infrared thermography (IRT) is a non-invasive and objective tool to do this. This systematic review evaluated the accuracy of IRT to determine burn wound healing potential. METHOD: This systematic review and meta-analysis used MEDLINE, EMBASE, CINAHL, PEDro, DiTA and CENTRAL databases. IRT data were extracted from primary studies and categorised into four cells (i.e., true positives, false positives, true negatives and false negatives). Subgroup analysis was performed according to methods used to capture thermal images. RESULTS: The search strategy identified 2727 publications; however, 15 articles were selected for review and 11 for meta-analysis. In our meta-analysis, the accuracy of IRT was 84.8% (63% sensitivity and 81.9% specificity). CONCLUSION: IRT is a moderately accurate tool to identify burn depth and healing potential. Thus, IRT should be used carefully for evaluating burn wounds.


Assuntos
Queimaduras , Termografia , Humanos , Termografia/métodos , Cicatrização , Queimaduras/diagnóstico , Queimaduras/terapia , Acetofenonas
9.
Reprod Domest Anim ; 59(4): e14556, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38566398

RESUMO

Scrotal surface thermography is a non-invasive method for assessing testicular thermoregulation in stallions; however, few studies have explored the application of this technique concerning the thermal physiology of equine reproductive systems. This study aimed to evaluate the consistency of testicular thermoregulation in stallions over a year using thermography to measure the scrotal surface temperature (SST). Moreover, we assessed the best region for measuring the surface body temperature compared with the SST. Ten light-breed stallions were used in the experiment. Thermographic images of the scrotal and body surfaces (neck and abdomen) were captured. Fresh, cooled and frozen-thawed semen samples were evaluated to verify the impact of thermoregulation on semen quality. Testicular thermoregulation was maintained throughout the year in stallions amidst changes in the external temperature, as evidenced by the weak correlation between the SST and ambient temperature. A lower correlation was observed between the environmental temperature and body surface temperature (BTS) obtained from the abdomen (BTS-A; R = .4772; p < .0001) than with that obtained from the neck (BTS-N; R = .7259; p < .0001). Moreover, both BTS-A and SST were simultaneously captured in a single image. The consistent quality of the fresh, cooled and frozen semen suggests efficient thermoregulation in stallions throughout the year.


Assuntos
Análise do Sêmen , Termografia , Animais , Cavalos , Masculino , Temperatura , Termografia/veterinária , Termografia/métodos , Análise do Sêmen/veterinária , Escroto/fisiologia , Testículo/fisiologia , Sêmen/fisiologia
10.
Trop Anim Health Prod ; 56(4): 138, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649543

RESUMO

Rectal temperature is widely used as an indicator of animal health. However, rectal temperature is conventionally measured by an invasive method, which may reduce animal welfare. So, this study aimed to determine the relationships between the deep-body (core) temperature and body surface temperatures in goats and develop a linear regression equation to establish the core temperature based on body surface temperatures. Body surface temperatures (head, eye, muzzle, horn, back, scrotum and groin) of goats were measured by infrared thermography (IRT). Ambient temperatures were measured by digital thermometer. Core temperatures were measured by a digital vet thermometer. Pearson correlation analysis was used to analyze the relationship between body surface temperatures, ambient temperature, and core temperature. Simple linear regression analysis was used to develop core temperature assessment equations. Correlation analysis showed that groin temperature was highly correlated with core temperature, and low correlated with ambient temperature. The body surface temperature of other region was low correlated with core temperature, and highly correlated with ambient temperature. Regression analysis showed that the determination coefficient of core temperature assessment equation based on groin temperature was the highest (P < 0.0001, R2 = 0.55), and those based on surface temperature of other regions were low (P < 0.01, R2 ≤ 0.16). We concluded that body surface temperatures obtained by IRT could be used for the assessment of goat core temperature. The core temperature assessment equations developed by the temperature of the body surface, which is less affected by ambient temperature, was found to have a higher determination coefficient than the equations developed using body surface temperature that is more affected by ambient temperature.


Assuntos
Temperatura Corporal , Cabras , Termografia , Animais , Cabras/fisiologia , Termografia/veterinária , Termografia/métodos , Masculino , Raios Infravermelhos , Feminino , Modelos Lineares
11.
Codas ; 36(2): e20220323, 2024.
Artigo em Português, Inglês | MEDLINE | ID: mdl-38629647

RESUMO

PURPOSE: To present a method for analyzing breathing modes with infrared thermography. METHODS: This exploratory cross-sectional study used 38 thermal images of inspiration and expiration with nasal breathing and simulated mouth breathing in four nasal breathers without respiratory complaints. Three different data selection forms (line, rectangle, and ellipse) were used to extract the minimum, mean, and maximum temperatures of the regions of interest (nose and mouth) using the FLIR Tools® software. RESULTS: Among the three selection forms, there was greater temperature variability obtained with the line, revealing limitations in this measurement. There were no differences between the rectangle and ellipse values, showing that both selection forms present similar temperature extraction results. The comparison results between nose and mouth temperatures during inspiration and expiration indicated a statistically significant difference between all measurements, except for mean inspiration temperatures with the rectangle and ellipse. The breathing mode can be distinguished in both inspiration and expiration when using mean mouth temperatures with the rectangle and ellipse. CONCLUSION: Breathing modes should be assessed based on mean mouth temperatures during inspiration, using the ellipse.


OBJETIVO: Apresentar um método de análise do modo respiratório por meio da termografia infravermelha. MÉTODO: Estudo transversal exploratório de 38 imagens térmicas que representavam o momento da inspiração e da expiração durante a respiração nasal e durante a simulação da respiração oral de quatro voluntárias respiradoras nasais sem queixas respiratórias. Para a extração da temperatura das regiões de interesse (nariz e boca) foram utilizadas três formas de seleção distintas de dados (linha, retângulo e elipse) e três medidas de temperatura (mínima, média e máxima) por meio do software FLIR Tools®. RESULTADOS: Dentre as três formas de seleção houve maior variabilidade nas medidas obtidas pela linha, revelando limitações nessa medida. Não houve diferenças entre as medidas do retângulo e elipse, mostrando que ambas as formas de seleção apresentam resultados semelhantes para a extração das temperaturas. Na comparação entre as temperaturas do nariz e da boca na inspiração e expiração, os resultados indicaram que houve diferença com relevância estatística em todas as medidas realizadas, exceto para as medidas de temperatura média da inspiração, usando o retângulo e a elipse. Percebe-se diferenciação do modo respiratório tanto na inspiração quanto na expiração quando utilizada a temperatura média da boca com o retângulo e a elipse. CONCLUSÃO: Sugere-se para avaliação do modo respiratório a avaliação da boca, por meio da elipse, com análise da temperatura média durante a inspiração.


Assuntos
Respiração , Termografia , Humanos , Projetos Piloto , Estudos Transversais , Nariz , Respiração Bucal
12.
JAMA Dermatol ; 160(5): 511-517, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38536160

RESUMO

Importance: Cellulitis is misdiagnosed in up to 30% of cases due to mimic conditions termed pseudocellulitis. The resulting overuse of antibiotics is a threat to patient safety and public health. Surface thermal imaging and the ALT-70 (asymmetry, leukocytosis, tachycardia, and age ≥70 years) prediction model have been proposed as tools to help differentiate cellulitis from pseudocellulitis. Objectives: To validate differences in skin surface temperatures between patients with cellulitis and patients with pseudocellulitis, assess the optimal temperature measure and cut point for differentiating cellulitis from pseudocellulitis, and compare the performance of skin surface temperature and the ALT-70 prediction model in differentiating cellulitis from pseudocellulitis. Design, Setting, and Participants: This prospective diagnostic validation study was conducted among patients who presented to the emergency department with acute dermatologic lower extremity symptoms from October 11, 2018, through March 11, 2020. Statistical analysis was performed from July 2020 to March 2021 with additional work conducted in September 2023. Main Outcomes and Measures: Temperature measures for affected and unaffected skin were obtained. Cellulitis vs pseudocellulitis was assessed by a 6-physician, independent consensus review. Differences in temperature measures were compared using the t test. Logistic regression was used to identify the temperature measure and associated cut point with the optimal performance for discriminating between cellulitis and pseudocellulitis. Diagnostic performance characteristics for the ALT-70 prediction model, surface skin temperature, and both combined were also assessed. Results: The final sample included 204 participants (mean [SD] age, 56.6 [16.5] years; 121 men [59.3%]), 92 (45.1%) of whom had a consensus diagnosis of cellulitis. There were statistically significant differences in all skin surface temperature measures (mean temperature, maximum temperature, and gradients) between cellulitis and pseudocellulitis. The maximum temperature of the affected limb for patients with cellulitis was 33.2 °C compared with 31.2 °C for those with pseudocellulitis (difference, 2.0 °C [95% CI, 1.3-2.7 °C]; P < .001). The maximum temperature was the optimal temperature measure with a cut point of 31.2 °C in the affected skin, yielding a mean (SD) negative predictive value of 93.5% (4.7%) and a sensitivity of 96.8% (2.3%). The sensitivity of all 3 measures remained above 90%, while specificity varied considerably (ALT-70, 22.0% [95% CI, 15.8%-28.1%]; maximum temperature of the affected limb, 38.4% [95% CI, 31.7%-45.1%]; combination measure, 53.9% [95% CI, 46.5%-61.2%]). Conclusions and Relevance: In this large diagnostic validation study, significant differences in skin surface temperature measures were observed between cases of cellulitis and cases of pseudocellulitis. Thermal imaging and the ALT-70 both demonstrated high sensitivity, but specificity was improved by combining the 2 measures. These findings support the potential of thermal imaging, alone or in combination with the ALT-70 prediction model, as a diagnostic adjunct that may reduce overdiagnosis of cellulitis.


Assuntos
Celulite (Flegmão) , Temperatura Cutânea , Termografia , Humanos , Celulite (Flegmão)/diagnóstico , Masculino , Feminino , Diagnóstico Diferencial , Pessoa de Meia-Idade , Estudos Prospectivos , Idoso , Termografia/métodos , Adulto , Valor Preditivo dos Testes , Leucocitose/diagnóstico , Serviço Hospitalar de Emergência
13.
Sensors (Basel) ; 24(6)2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38543986

RESUMO

INTRODUCTION: The aim of this study was to observe the validity, diagnostic capacity, and reliability of the thermographic technique in the analysis of sensitive and motor sequelae in patients with chronic brain damage. METHOD: A longitudinal descriptive observational study was performed. Forty-five people with impairment in at least one anatomical region participated in and completed this study. All patients who had become infected by SARS-CoV-2 in the past year were excluded. Thermographic measurement was conducted, and the Modified Ashworth Scale and Pressure Pain Threshold was analyzed. RESULTS: A high correlation between two times of thermography data was observed. The Spearman correlations obtained between the Ashworth score on each leg and the temperature given by thermography were all significant. DISCUSSION AND CONCLUSIONS: Despite the above, the Spearman correlations obtained between the PPT in each leg and the temperature offered by thermography were not significant in any of the measurements. For this reason, thermography is a potential tool for the diagnosis and assessment of neuromuscular motor sequelae, but not for sensitive sequelae, after brain injury. Nevertheless, for the time being, no statistical relationship has been observed between the data reported by thermography and PPT; thus, future studies are needed to further investigate these results.


Assuntos
Lesões Encefálicas , Termografia , Humanos , Termografia/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Lesões Encefálicas/diagnóstico , Encéfalo
14.
Neurol Res ; 46(5): 391-397, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38468476

RESUMO

OBJECTIVES: Wallenberg's syndrome (WS) is caused by a stroke in the lateral medulla and can present with various symptoms. One of the main symptoms is vertigo, which can be misdiagnosed as noncentral vertigo (NCV). Approximately 90% of the patients with acute WS have a lateral difference in body surface temperature (BST) due to autonomic pathway disturbances from infarction. Additionally, thermography can aid in WS diagnosis; however, whether BST differences occur in patients with acute NCV is unclear. METHODS: This study used thermography to measure the BST of patients with NCV and acute WS to determine the effectiveness of BST to differentiate between the conditions. Forty-eight consecutive patients diagnosed with NCV whose BST was measured using thermography during a hospital visit or admission were enrolled. The left and right BST of four sites (face, trunk, and upper and lower limbs) were measured and compared with obtained BST of nine patients with WS. RESULTS: Twenty-two patients had lateral differences in BST ≥ 0.5°C, three with ≥1.5°C, and none with ≥2.5°C. Only one patient with NCV had lateral differences in BST at two or more ipsilateral sites. When WS differentiated from NCV, a left-right difference ≥0.5°C in two or more ipsilateral sites had a sensitivity of 89% and specificity of 98%, and ≥1.0°C had a sensitivity of 78% and specificity of 98%. DISCUSSION: Acute WS can be differentiated from NCV through BST and the number of sites with lateral differences via thermography, even in rooms where conditions are unregulated.


Assuntos
Síndrome Medular Lateral , Termografia , Vertigem , Humanos , Masculino , Termografia/métodos , Feminino , Pessoa de Meia-Idade , Idoso , Vertigem/diagnóstico , Vertigem/etiologia , Vertigem/fisiopatologia , Síndrome Medular Lateral/diagnóstico , Síndrome Medular Lateral/complicações , Síndrome Medular Lateral/fisiopatologia , Diagnóstico Diferencial , Adulto , Idoso de 80 Anos ou mais , Temperatura Corporal/fisiologia
15.
Magn Reson Med ; 92(1): 15-27, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38501903

RESUMO

Proton resonance frequency shift (PRFS) MR thermometry is the most common method used in clinical thermal treatments because of its fast acquisition and high sensitivity to temperature. However, motion is the biggest obstacle in PRFS MR thermometry for monitoring thermal treatment in moving organs. This challenge arises because of the introduction of phase errors into the PRFS calculation through multiple methods, such as image misregistration, susceptibility changes in the magnetic field, and intraframe motion during MRI acquisition. Various approaches for motion correction have been developed for real-time, motion-robust, and volumetric MR thermometry. However, current technologies have inherent trade-offs among volume coverage, processing time, and temperature accuracy. These tradeoffs should be considered and chosen according to the thermal treatment application. In hyperthermia treatment, precise temperature measurements are of increased importance rather than the requirement for exceedingly high temporal resolution. In contrast, ablation procedures require robust temporal resolution to accurately capture a rapid temperature rise. This paper presents a comprehensive review of current cutting-edge MRI techniques for motion-robust MR thermometry, and recommends which techniques are better suited for each thermal treatment. We expect that this study will help discern the selection of motion-robust MR thermometry strategies and inspire the development of motion-robust volumetric MR thermometry for practical use in clinics.


Assuntos
Imageamento por Ressonância Magnética , Movimento (Física) , Humanos , Imageamento por Ressonância Magnética/métodos , Termometria/métodos , Termografia/métodos , Algoritmos , Hipertermia Induzida , Artefatos
16.
Meat Sci ; 213: 109483, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38484580

RESUMO

This study investigated the use of infrared thermography (IRT) to identify the dark, firm, and dry (DFD) phenomenon in Brazilian beef, which is a significant concern for the industry because of its inferior quality and reduced shelf life. This study examined 113 Nellore bulls and analyzed their minimum and maximum ocular temperatures using IRT. The results highlight the efficacy of thermal images (IRTmax) as a significant predictor, with R2 values ranging from 0.84 to 0.88 for calibration models. The inclusion of parameters such as glucose and lactate further enhanced prediction accuracy. The models also revealed that the combination of features, such as lightness (L*), redness (a*), and yellowness (b*), contributed to the precise prediction of pHu, with an R2 of 0.88. In model validation, RMSEP ranged from 0.104 to 0.158, indicating good generalization capability. The RPD, ranging from 1.7 to 2.6, suggests satisfactory quantitative prediction. The statistical significance of all models, evidenced by P-values <0.001, strengthens the reliability of the results. In conclusion, the models support the use of IRT as a tool for identifying pHu alterations in carcasses. When combined with blood parameters, they may exhibit even greater efficiency in predicting pHu in Nelore cattle carcasses, highlighting the potential applicability of these methods in the beef industry.


Assuntos
Carne Vermelha , Termografia , Animais , Bovinos , Termografia/veterinária , Termografia/métodos , Concentração de Íons de Hidrogênio , Carne Vermelha/análise , Masculino , Cor , Raios Infravermelhos , Qualidade dos Alimentos , Reprodutibilidade dos Testes , Brasil
17.
Animal ; 18(3): 101096, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38377813

RESUMO

Bovine respiratory disease (BRD) is a highly prevalent multi pathogen infectious disease (70-80%) in newly received feedlot cattle, causing significant economic losses and reduced animal welfare. Current BRD diagnosis involves stressful and invasive methods that can increase the incidence and transmission of BRD. An alternative is the use of an automated infrared thermography (IR) platform that can monitor facial temperature and behaviour traits to diagnose BRD in a non-invasive manner. The objective of this study was to investigate the use of fidget and drinking behaviours in conjunction with facial temperature as method of BRD diagnosis in beef calves. Sixty-five weaned calves (N = 65) were monitored over a 21-d period after 6 h transportation to predispose calves to BRD infection. Data collected from an automated IR platform placed at a water station included the number of IR frames during drinking (Fidget), number of drinking visits (Drinking bouts), total drinking duration, average drinking duration, average cheek temperature (AVG temp), and maximum orbital temperature (Max temp). Fidget, drinking behaviours, and IR were compared to a clinical score assessment based on respiratory, digestive, and lethargy signs (visual observation) and haematology analysis using a receiver operating characteristics curve analysis to identify the accuracy of each metric and combinations of metrics for BRD diagnosis. The greater accuracies observed were Fidget, Youden's index (J): 0.25 J), Drinking bout (0.28 J), and Total drinking duration (0.22 J). The average IR temperature accuracy resulted in 0.88 J and Max temp 0.77 J. Thirty-five combinations of drinking behaviour and facial IR metrics were evaluated to identify BRD calves. Optimum accuracy (100%) was achieved when combining Fidget, Drinking bout, Average drinking duration, AVG temp, and Max temp 1.00 J. Similar evaluations were performed at 48 and 24 h before d 0 using the most accurate Fidget, Drinking behaviour, and IR combination, resulting in 0.44 J 48 h prior to d 0 and 0.45 J 24 h prior to d 0. Combining fidget and drinking behaviour metrics increased the sensitivity to detect the onset of BRD infection and the specificity to discriminate true positive BRD calves from true negative BRD calves.


Assuntos
Complexo Respiratório Bovino , Doenças dos Bovinos , Bovinos , Animais , Complexo Respiratório Bovino/diagnóstico , Complexo Respiratório Bovino/epidemiologia , Termografia/veterinária , Doenças dos Bovinos/diagnóstico , Desmame , Fenótipo , Comportamento de Ingestão de Líquido
18.
Dent Mater ; 40(3): 546-556, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38326211

RESUMO

OBJECTIVES: This study investigated effects of the different emittance-mode protocols from three light curing units (LCUs): (i) a Laser (Monet); (ii) a quad-wave (PinkWave); (iii) a conventional LED (Elipar S10) on the temperature rise (ΔT) and degree of conversion (DC) when photo-curing fast or conventional bulk-fill resin-based composites (RBC). The aim was to correlate ΔT and DC, and the radiant exposure delivered to RBC specimens. METHODS: A 3D-printed resin mold of 4 mm depth was filled with two bulk-fill RBCs: Tetric PowerFill® (fast photo-polymerised composite) (TPF) or Tetric EvoCeram® Bulk-Fill (EVO). Three LCUs were used: (i) Monet laser for 1 s and 3 s (MONET-1 s, MONET-3 s); (ii) PinkWave quad-wave used for 3 s in Boost mode (PW-3 s) and for 20 s in standard mode (PW-20 s); (iii) Elipar S10 for 5 s (S10-5 s) and for 20 s in standard mode (S10-20 s). 2-dimensional temperature maps were obtained before, during and for 60 s after the LCU had turned off using a thermal imaging camera. Thermal changes were analysed at five depths: (0, 1, 2, 3, and 4 mm from the top surface of the RBC). The maximum temperature rise (Tmax) and the mean temperature rise (ΔT) were determined. Cylindrical-shaped specimens were prepared from each material using a stainless-steel split mold (4 × 4 mm) and light-cured with the same protocols. The DC was measured for 120 s and at 1 h after LCU had turned off using Fourier Transform Infrared Spectroscopy (FTIR). Data were analysed using Three-way ANOVA, One-way ANOVA, independent t-tests, and Tukey post-hoc tests (p < 0.05). RESULTS: Radiant exposures delivered by the various irradiation protocols were between 4.5-30.3 J/cm2. Short exposure times from MONET-1 s and PW-3 s delivered the lowest radiant exposures (4.5 and 5.2 J/cm2, respectively) and produced the lowest ΔT and DC. The longer exposure times in the standard modes of PW-20 s, S10-20 s, and MONET-3 s produced the highest Tmax, ΔT, and DC for both composites. The ΔT range among composites at different depths varied significantly (31.7-49.9 °C). DC of TPF ranged between 30-65% and in EVO between 15.3-56%. TPF had higher Tmax, ΔT for all depths and DC compared to EVO, across the LCU protocols (p < 0.05), except for PW-20 s and MONET-3 s. The coronal part of the restorations (1-2 mm) had the highest ΔT. There was a positive correlation between ΔT and DC at 4-mm depth after 120 s SIGNIFICANCE: Longer, or standard, exposure times of the LCUs delivered greater radiant exposures and had higher DC and ΔT compared to shorter or high-irradiance protocols. The fast photo-polymerised RBC had comparatively superior thermal and conversion outcomes when it received a high irradiance for a short time (1-5 s) compared to the conventional Bulk-Fill RBC.


Assuntos
Lâmpadas de Polimerização Dentária , Termografia , Teste de Materiais , Resinas Compostas/química , Materiais Dentários , Cura Luminosa de Adesivos Dentários/métodos , Polimerização
19.
J Therm Biol ; 119: 103790, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38354493

RESUMO

To evaluate the use of infrared thermography to assess the thermal status of heat-stressed and water-deprived Capra hircus, full-body surface temperature (TS) and six other body-thermal variables [core, rectal (TR), and skin (TSK) temperatures, respiratory and heart rates, and total body-thermal gradient (core-to-ambient, BTG)] were measured after three days of euhydration (EU), dehydration (DE), and rehydration (RE). Results revealed that the combined effect of heat stress and water deprivation had affected all tested variables including the TS, and once these animals gained access to water in the RE stage variables returned to their EU levels. Moreover, there were positive correlations between TS and all variables with the exception of BTG. From these six variables, only three variables (i.e. the TR, TSK, and BTG) during the DE stage and two variables (i.e. the TSK and BTG) throughout the experimental stages showed higher constancy (R2 ≥ 0 75, P < 0 001; agreement intervals ±1 96 95 % CI) with TS. However, BTG appeared more closely correlated with TS, representing the body-thermal status more realistically than other variables. In effect, the mean and thresholds of the BTG were predicted using the recorded TS and were within 0.02 °C of original estimates. Collectively, these findings show that infrared thermography is appropriate for assessing body-thermal status, and thus the welfare, of these animals under the three conditions studied, and conclude that full-body TS can be a surrogate proxy for BTG in these animals. Further experiments are needed to adequately examine the reproducibility of these results under biometeorologically-simulated environments and natural habitats.


Assuntos
Transtornos de Estresse por Calor , Termografia , Animais , Termografia/métodos , Desidratação/diagnóstico , Desidratação/veterinária , Privação de Água , Cabras , Reprodutibilidade dos Testes , Temperatura Corporal/fisiologia , Resposta ao Choque Térmico , Água
20.
Ann Biomed Eng ; 52(4): 1078-1090, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38319506

RESUMO

This study proposes using magnetically induced currents in medical infrared imaging to increase the temperature contrast due to the electrical conductivity differences between tumors and healthy tissues. There are two objectives: (1) to investigate the feasibility of this active method for surface and deep tumors using numerical simulations, and (2) to demonstrate the use of this method through different experiments conducted with phantoms that mimic breast tissues. Tumorous breasts were numerically modeled and simulated in active and passive modes. At 750 kHz, the applied current was limited for breast tissue-tumor conductivities (0.3 S/m and 0.75 S/m) according to the local specific absorption rate limit of 10 W/kg. Gelatin-based and mashed potato phantoms were produced to mimic tumorous breast tissues. In the simulation studies, the induced current changed the temperature contrast on the imaging surface, and the tumor detection sensitivity increased by 4 mm. An 11-turn 70-mm-long solenoid coil was constructed, 20 A current was applied for deep tumors, and a difference of up to 0.4  ∘ C was observed in the tumor location compared with the temperature in the absence of the tumor. Similarly, a 23-turn multi-layer coil was constructed, and a temperature difference of 0.4  ∘ C was observed. The temperature contrast on the body surface changed, and the tumor detection depth increased with the induced currents in breast IR imaging. The proposed active thermal imaging method was validated using numerical simulations and in vitro experiments.


Assuntos
Neoplasias da Mama , Mama , Humanos , Feminino , Mama/patologia , Temperatura , Temperatura Corporal , Termografia/métodos , Imagens de Fantasmas , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...