Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
J Nucl Cardiol ; 24(2): 482-490, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-26809439

RESUMO

BACKGROUND: The prognostic value of left ventricular dyssynchrony measured by gated single-photon emission computed tomography (GSPECT) myocardial perfusion imaging (MPI) and its relationship to electrical dyssynchrony measured by QRS duration are incompletely understood. The aim of this study was therefore to examine the independent and incremental prognostic value of dyssynchrony in yet the largest group of patients with coronary artery disease (CAD). METHODS AND RESULTS: Patients presenting for GSPECT- MPI between July 1993 and May 1999 in normal sinus rhythm were identified from the Duke Nuclear Cardiology Databank and the Duke Databank for Cardiovascular Disease (N = 1244). After a median of 4.2 years, 336 deaths occurred. At 8 years, the Kaplan-Meier estimates of the probability of death were 34.0% among patients with a phase bandwidth <100° and 56.8% among those with a bandwidth ≥100°. After adjustment for standard clinical variables, QRS dyssynchrony was independently associated with death (Hazard Ratio (HR), per 10°: 1.092, 95% Confidence Interval (CI) 1.048,1.139, P < .0001). Phase bandwidth was similarly associated with death after clinical adjustment (HR per 10°: 1.056, 95% CI 1.041,1.072, P < .0001). In clinically adjusted models examining QRS duration in addition to phase bandwidth, phase bandwidth had a stronger association with mortality. After accounting for left ventricular ejection fraction (LVEF), neither QRS duration nor phase bandwidth were statistically significant. Among patients with EF >35%, QRS duration and phase bandwidth together provided value above that provided by LVEF alone (P = 0.0181). When examining cardiovascular death, results were consistent with all-cause death. CONCLUSIONS: Among patients with CAD, mechanical left ventricular dyssynchrony measured by GSPECT MPI has a stronger relationship with outcomes than electrical dyssynchrony measured by QRS duration. After adjustment for baseline characteristics and LVEF, neither mechanical nor electrical dyssynchrony is independently associated with all-cause death or cardiac death. Among patients with EF >35%, mechanical and electrical dyssynchrony together provided prognostic value above that afforded by LVEF.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Imagem do Acúmulo Cardíaco de Comporta/métodos , Imagem de Perfusão do Miocárdio/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/mortalidade , Idoso , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/estatística & dados numéricos , Comorbidade , Feminino , Imagem do Acúmulo Cardíaco de Comporta/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/estatística & dados numéricos , North Carolina/epidemiologia , Prevalência , Prognóstico , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Análise de Sobrevida
2.
Nucl Med Commun ; 38(1): 35-43, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27775993

RESUMO

OBJECTIVE: The aim of this study was to assess the feasibility of IQ-SPECT gated blood pool (MUGA) under conditions of decreased scan time (ST). PATIENTS AND METHODS: Ten patients underwent routine 26-min, two-view planar, followed by LEHR and IQ-SPECT MUGA, on a Siemens dual-head Symbia scanner. Six 'back and forth' 4-min SPECT scans were summed into 4-, 8-, 12-, 16-, 20-, and 24-min equivalent scans, and reconstructed iteratively (IQ-SPECT and LEHR) and with FBP (LEHR). Uniformity, contrast, and wall motion were scored on a five-point scale. Linear regressions of left ventricular (LV) ejection fraction (EF) were performed between FBP, Flash 3D, and IQ-SPECT versus planar and Flash 3D and IQ-SPECT versus FBP. Agreement tables between Flash 3D and IQ-SPECT versus FBP LV EF were generated using a normal versus cardiotoxicity threshold of 50%. RESULTS: IQ-SPECT had the best scores for all STs, and 4, 8, and 16 min IQ-SPECT were judged to be similar to 24-min LEHR FBP, Flash 3D, and planar, respectively. The average LV EF correlation coefficients were 0.69, 0.71, and 0.63 between IQ-SPECT, Flash 3D, and FBP versus planar, respectively; 0.70 between IQ-SPECT and FBP; and 0.88 between Flash 3D and FBP, and all were statistically significant (P<0.05), except for 16-min FBP LEHR versus planar. Agreement tables showed diagnostic equivalence of IQ-SPECT, Flash 3D, and FBP. CONCLUSION: These preliminary results suggest that IQ-SPECT is equivalent to LEHR Flash 3D and FBP for MUGA SPECT, and better at reduced ST. A larger patient population study is necessary for a more definitive assessment.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Imagem do Acúmulo Cardíaco de Comporta/métodos , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/estatística & dados numéricos , Estudos de Viabilidade , Imagem do Acúmulo Cardíaco de Comporta/estatística & dados numéricos , Humanos , Imageamento Tridimensional/métodos , Imageamento Tridimensional/estatística & dados numéricos , Fatores de Tempo
3.
J Dtsch Dermatol Ges ; 14(10): 1007-1014, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27767272

RESUMO

BACKGROUND: In recent years, cardiac comorbidities in psoriasis patients have increasingly moved into the focus of clinical research. The objective of the present study was to evaluate myocardial scintigraphy as a screening method in patients with psoriasis. PATIENTS AND METHODS: Assessment of various comorbidities in 50 psoriasis patients without clinical symptoms of cardiac disease. Myocardial scintigraphy was employed to detect cardiac risk/exercise-induced ischemia. RESULTS: Twenty-eight patients (56 %) had pathological findings on myocardial scintigraphy. Fourteen individuals showed evidence of small-vessel disease (cardiac syndrome X). Other comorbidities included obesity, arterial hypertension, nicotine and alcohol abuse, as well as elevated CRP levels. Frequencies largely corresponded to those reported in the recent literature. There was no significant correlation between the severity of psoriasis or any comorbidities and pathological findings on myocardial scintigraphy. CONCLUSIONS: Myocardial scintigraphy seems to be a very sensitive, noninvasive method for the early detection of cardiac comorbidities in psoriasis patients. However, determining its true diagnostic value will require larger studies with control subjects and control methods such as coronary angiography.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Angina Microvascular/diagnóstico por imagem , Angina Microvascular/epidemiologia , Psoríase/diagnóstico por imagem , Psoríase/epidemiologia , Adulto , Idoso , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/estatística & dados numéricos , Comorbidade , Feminino , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade
4.
Nucl Med Commun ; 37(11): 1139-47, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27341412

RESUMO

OBJECTIVE: Phase analysis using gated myocardial perfusion single-photon emission computed tomography (GMPS) is a tool used to assess left ventricular (LV) dyssynchrony. We attempted to investigate the role of LV dyssynchrony assessed by GMPS using phase analysis for the late LV function after coronary artery bypass graft surgery (CABG) in patients with patent grafts. METHODS: A total of 45 patients who received off-pump CABG with patent graft 1 year after CABG and preserved perfusion reserve were enrolled retrospectively. All patients underwent GMPS before and 3 months and 1 year after CABG. Using the Emory Cardiac Toolbox, both phase histogram bandwidth (PBW) and phase SD derived by phase analysis were used for the analysis, in addition to the conventional perfusion parameters. For the evaluation of LV function, transthoracic echocardiography was also performed. RESULTS: All of the patients showed perfusion improvement (paired t-test, P<0.05) after CABG. Nonetheless, 30 of 45 patients showed LV dyssynchrony 3 months after CABG. One year after CABG, however, 25 out of 45 patients showed reverse remodeling. Among those patients with reverse remodeling, 19 patients had shown LV 3 months after CABG. Using stepwise logistic regression with forward selection, PBW 3 months after CABG could predict reverse remodeling 1 year after CABG (odds ratio 1.03, P<0.05). Using receiver operating characteristic analysis, PBW 3 months after CABG had the largest area under the curve to detect reverse remodeling 1 year after CABG with a cut-off value of 82 (sensitivity 0.95, specificity 0.56, P<0.001). CONCLUSION: Postoperative LV dyssynchrony assessed by GMPS using phase analysis may reflect late reverse remodeling and potential of further functional improvement in patients with patent grafts and preserved perfusion reserve after CABG.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Ponte de Artéria Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/estatística & dados numéricos , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Fatores de Tempo , Remodelação Ventricular
5.
J Nucl Cardiol ; 23(6): 1470-1476, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-26719152

RESUMO

BACKGROUND: Combined supine-prone myocardial perfusion imaging (CSP MPI) has been shown to reduce attenuation artifact in comparison to supine-only (SU) MPI in mixed-gender populations with varying risk for coronary artery disease (CAD), often where patients served as their own controls. However, there is limited direct comparison of these imaging strategies in men. METHODS: 934 male patients underwent CSP or SU MPI. Diagnostic certainty of interpretation was compared. Within the cohort, 116 were referred for left heart catheterization (LHC) to assess for CAD. Sensitivity, specificity, and area under the curve (AUC) were compared with additional analysis based on body mass index (BMI). RESULTS: 597 patients completed the SU protocol and 337 patients completed the CSP protocol. Equivocal studies were seen more frequently in the SU group (13%) than in the CSP group (4%, P < .001). At catheterization, the specificity for CSP MPI of 70% was higher than 40% for SU MPI (P = .032). The CSP AUC (0.80 ± 0.06) was significantly larger than SU AUC (0.57 ± 0.05, P = .004). CSP specificity was significantly higher in obese patients. CONCLUSIONS: CSP MPI increases diagnostic certainty and improves test accuracy for CAD detection in men with CAD risk factors, especially obese patients, compared to SU MPI.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/estatística & dados numéricos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Imagem de Perfusão do Miocárdio/estatística & dados numéricos , Obesidade/epidemiologia , Posicionamento do Paciente/estatística & dados numéricos , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Comorbidade , Feminino , Florida/epidemiologia , Humanos , Masculino , Saúde do Homem , Imagem de Perfusão do Miocárdio/métodos , Obesidade/diagnóstico por imagem , Posicionamento do Paciente/métodos , Prevalência , Decúbito Ventral , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Decúbito Dorsal
6.
Hell J Nucl Med ; 18(3): 199-206, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26574691

RESUMO

OBJECTIVE: Coronary artery disease (CAD) is highly prevalent in patients with end-stage renal disease (ESRD), owing to clustering of traditional and uremic-specific risk factors. However, in this population asymptomatic course of CAD is common and it has been reported that myocardial perfusion imaging (MPI) with single-photon emission tomography (SPET) has lower sensitivity. In the current study, we assessed the value of MPI gated-SPET and its combination with coronary artery calcium (CAC) score measurements in risk stratification of ESRD patients. MATERIALS AND METHODS: MPI gated-SPET was performed with dual-headed SPET camera and CAC score measured by multi-detector computed tomography (MDCT) system.There were tested 77 ESRD individuals. During the follow-up study, cardiac events (CE) defined as cardiac death or nonfatal myocardial infarction (MI) or the necessity for coronary revascularization were recorded. Univariate and stepwise multivariable Cox proportional hazards-models were used to identify the predictors of CE. RESULTS: Eighteen CE were recorded during the follow-up. They were significantly associated with higher summed stress scores on MPI, higher percentage of ischaemic myocardium, higher occurrence of defects in multiple territories and higher CAC score (all with P<0.05). Univariate Cox proportional hazard-models showed that severe perfusion abnormalities as well as CAC score ≥1000 were significantly associated with cardiac events (P<0.0001, P=0.0056). In stepwise Cox proportional hazards-models considering age, gender, history of diabetes mellitus, post-stress left ventricular stunning, the degree of perfusion abnormality and CAC score, only severe perfusion abnormalities and CAC score ≥1000 were independent predictors of CE. There was no CE in patients with normal perfusion, normal function and zero CAC score. CONCLUSION: This study suggests that combined evaluation of MPI and CAC can predict the outcome in ESRD individuals, while severe perfusion abnormality on gated-SPET and high CAC score ≥1000 are predictors of future cardiac events.


Assuntos
Calcinose/diagnóstico por imagem , Calcinose/mortalidade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Falência Renal Crônica/mortalidade , Imagem de Perfusão do Miocárdio/estatística & dados numéricos , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/estatística & dados numéricos , Comorbidade , República Tcheca/epidemiologia , Feminino , Humanos , Falência Renal Crônica/diagnóstico por imagem , Falência Renal Crônica/etiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Prognóstico , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Taxa de Sobrevida
7.
J Nucl Cardiol ; 21(3): 532-40, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24623397

RESUMO

BACKGROUND: Left ventricular (LV) dyssynchrony by phase analysis has been studied by myocardial perfusion imaging (MPI)-gated SPECT in patients with LV dysfunction in various clinical settings. We aimed to investigate the routine use of phase analysis with gated SPECT for predicting cardiac outcome. METHODS: Patients referred to a tertiary medical center in 2010-2011 prospectively underwent a gated SPECT and phase analysis, and follow-up for cardiac events. The values of clinical variables, MPI, LV function, and LV dyssynchrony in predicting cardiac events were tested by univariate and multivariate analyses. RESULTS: The study group included 787 patients (66.5 ± 11 years, 81% men) followed for a mean duration of 18.3 ± 6.2 months. There were 45 (6%) cardiac events defined as composite endpoint; cardiac death occurred in 26 patients, and the rest had new-onset or worsening heart failure and life-threatening arrhythmias. In multivariate analysis, it was shown that NYHA class, diabetes mellitus, and LVEF <50% were the independent predictors for composite endpoint. However, the independent predictors for cardiac mortality were NYHA class (for each increment in class) and phase standard deviation (SD) (for each 10° increment). CONCLUSION: Gated SPECT with phase analysis for the assessment of LV dyssynchrony can successfully predict cardiac death together with NYHA class, in patients with LV dysfunction.


Assuntos
Arritmias Cardíacas/mortalidade , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/estatística & dados numéricos , Morte Súbita Cardíaca/epidemiologia , Insuficiência Cardíaca/mortalidade , Imagem de Perfusão do Miocárdio/estatística & dados numéricos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/mortalidade , Idoso , Arritmias Cardíacas/diagnóstico por imagem , Causalidade , Comorbidade , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Incidência , Israel/epidemiologia , Masculino , Prognóstico , Valores de Referência , Reprodutibilidade dos Testes , Medição de Risco , Sensibilidade e Especificidade , Taxa de Sobrevida
9.
Eur J Radiol ; 83(6): 951-956, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24666512

RESUMO

PURPOSE: The present meta-analysis illustrates the accuracy of myocardial perfusion SPECT (MPS) to diagnose functional stenotic coronary artery disease (CAD) with fractional flow reserve (FFR) as standard reference. METHODS: All investigators screened and selected studies that compared MPS with FFR in symptomatic patients with suspected CAD. Patients and study characteristics were independently extracted by two investigators; differences were resolved by consensus. RESULTS: 13 articles, including 1,017 patients, 699 vessels were included in the study. No significant publication bias was detected (P=0.65). At the patient level, the summary sensitivity and specificity were 77% (95% confidence interval [CI], 70-83%) and 77% (95%CI, 67-84%) for MPS. Vessel-level pooled sensitivity was 66% (95%CI, 57-74%) and specificity was 81% (95%CI, 70-89%). The overall diagnostic performance of MPS was moderate. [The area under the summary receiver operating characteristic (sROC) curve was 0.83]. No study influenced the pooled results larger than 0.03. CONCLUSIONS: The accuracy between FFR and MPS SPECT was moderate.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/estatística & dados numéricos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/epidemiologia , Reserva Fracionada de Fluxo Miocárdico , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/epidemiologia , Imagem de Perfusão do Miocárdio/estatística & dados numéricos , Idoso , Causalidade , Comorbidade , Angiografia Coronária/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade
10.
Eur J Nucl Med Mol Imaging ; 41(5): 963-71, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24519554

RESUMO

PURPOSE: For several years the Working Group Cardiovascular Nuclear Medicine of the German Society of Nuclear Medicine has been performing a regular survey to obtain information on technique, utilization and development of myocardial perfusion scintigraphy (MPS). Currently, data of six surveys from 2005 to 2012 are available. The aim of this paper is to deliver a general and comprehensive overview of all surveys documenting the course of patient doses over time and the development of the method. METHODS: A one-page questionnaire with number of MPS patients, number of stress and rest MPS, referral structure and several technical issues was sent to all centres performing MPS in Germany and evaluated. With the data on protocol utilization, effective MPS patient doses were estimated. RESULTS: MPS per million population (pmp) varied between 2,380 and 2,770. In 2012, MPS pmp showed a slight increase for the first time. From 2005 to 2009 the angiography to MPS ratio increased from 3.4 to 4.4, and the revascularization to MPS ratio decreased from 0.66 to 0.53. In 2012, both indices demonstrated an opposite trend for the first time (4.1 and 0.55). A total of 108 centres participated in all surveys. They showed an increase in MPS patients of 4.0 % over the reporting period. In 2012, more than 50 % of the centres experienced no change or an increase in MPS numbers. The leading single competitor was MRI, followed by angiography and stress echocardiography. (201)Tl studies have decreased since 2005 from 20 to 5 %. (99m)Tc MPS studies showed a mild increase in 2-day protocols. In 2012, the average effective dose per patient was estimated at 7.4 mSv. Due to the decreasing use of (201)Tl, a mild decline over the observation period can be documented. Dynamic exercise stress was the most common stress test and adenosine the leading pharmacological stress agent, with a growing percentage. In 2012, the regadenoson percentage was 9 %. Gated single photon emission computed tomography (SPECT) noted an increasing acceptance with >70 % in 2012. The segmental scoring of perfusion studies had a low acceptance. Ambulatory care cardiologists represented the major referral group. CONCLUSION: Germany has a moderate to moderate-high MPS utilization rate. Nevertheless, coronary artery disease (CAD) diagnosis and disease management are dominated by angiography. The survey data reveal a positive trend in MPS and a decrease in average patient dose reflecting good practice with guideline adherence, the implementation of technical improvements and success in training.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/estatística & dados numéricos , Imagem de Perfusão do Miocárdio/estatística & dados numéricos , Doses de Radiação , Idoso , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Alemanha , Humanos , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/métodos
11.
J Nucl Cardiol ; 21(3): 416-23, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24442889

RESUMO

BACKGROUND: The aim of this myocardial perfusion imaging (MPI) study was to compare the diagnostic performance of two computer-aided diagnosis (CAD) systems, EXINI Heart(TM) (EXINI), and PERFEX(TM) (PERFEX) Emory Cardiac Toolbox (ECT), and the summed stress score (SSS) values from both software packages. METHODS: We studied 1,052 consecutive patients who underwent 2-day stress/rest (99m)Tc-sestamibi MPI studies. The reference standard classifications for the MPI studies were obtained from three experienced physicians who separately classified all cases regarding the presence or absence of ischemia and/or infarction. Automatic processing was carried out using EXINI and PERFEX to obtain CAD results and SSS values based on the 17-segment model. RESULTS: The three experts' classifications showed ischemia in 257 patients and abnormal studies, i.e., either ischemia or infarction or both, in 318 patients. Accuracy was significantly higher in EXINI than in PERFEX, regarding both the detection of ischemia (87.4 vs 77.6%; P < 0.0001) and the detection of abnormal studies (91.6 vs 67.9%; P < 0.0001). EXINI's CAD system showed a higher specificity than its SSS values (86.8 vs 73.6%; P < 0.0001) at the same level of sensitivity. CONCLUSIONS: EXINI demonstrated greater diagnostic accuracy for detection of ischemia and abnormal studies than did PERFEX. EXINI CAD also outperformed its SSS analysis.


Assuntos
Algoritmos , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/estatística & dados numéricos , Doença da Artéria Coronariana/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagem de Perfusão do Miocárdio/estatística & dados numéricos , Reconhecimento Automatizado de Padrão/métodos , Software , Adulto , Idoso , Idoso de 80 Anos ou mais , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/métodos , Variações Dependentes do Observador , Reconhecimento Automatizado de Padrão/estatística & dados numéricos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Validação de Programas de Computador
12.
J Nucl Cardiol ; 21(2): 305-18, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24310280

RESUMO

BACKGROUND: Recent studies have compared CTA to stress testing and MPI using older Na-I SPECT cameras and traditional rest-stress protocols, but are limited by often using optimized CTA protocols but suboptimal MPI methodology. We compared CTA to stress testing with modern SPECT MPI using high-efficiency CZT cameras and stress-first protocols in an ED population. METHODS: In a retrospective, non-randomized study, all patients who underwent CTA or stress testing (ETT or Tc-99m sestamibi SPECT MPI) as part of their ED assessment in 2010-2011 driven by ED attending preference and equipment availability were evaluated for their disposition from the ED (admission vs discharge, length of time to disposition), subsequent visits to the ED and diagnostic testing (within 3 months), and radiation exposure. CTA was performed using a 64-slice scanner (GE Lightspeed VCT) and MPI was performed using a CZT SPECT camera (GE Discovery 530c). Data were obtained from prospectively acquired electronic medical records and effective doses were calculated from published conversion factors. A propensity-matched analysis was also used to compare outcomes in the two groups. RESULTS: A total of 1,458 patients underwent testing in the ED with 192 CTAs and 1,266 stress tests (327 ETTs and 939 MPIs). The CTA patients were a lower-risk cohort based on age, risk factors, and known heart disease. A statistically similar proportion of patients was discharged directly from the ED in the stress testing group (82% vs 73%, P = .27), but their time to disposition was longer (11.0 ± 5 vs 20.5 ± 7 hours, P < .0001). There was no significant difference in cardiac return visits to the ED (5.7% CTA vs 4.3% stress testing, P = .50), but more patients had follow-up studies in the CTA cohort compared to stress testing (14% vs 7%, P = .001). The mean effective dose of 12.6 ± 8.6 mSv for the CTA group was higher (P < .0001) than 5.0 ± 4.1 mSv for the stress testing group (ETT and MPI). A propensity score-matched cohort showed similar results to the entire cohort. CONCLUSIONS: Stress testing with ETT, high-efficiency SPECT MPI, and stress-only protocols had a significantly lower patient radiation dose and less follow-up diagnostic testing than CTA with similar cardiac return visits. CTA had a shorter time to disposition, but there was a trend toward more revascularization than with stress testing.


Assuntos
Síndrome Coronariana Aguda/diagnóstico , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/estatística & dados numéricos , Dor no Peito/diagnóstico , Angiografia Coronária/estatística & dados numéricos , Teste de Esforço/estatística & dados numéricos , Imagem de Perfusão do Miocárdio/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Síndrome Coronariana Aguda/epidemiologia , Causalidade , Dor no Peito/epidemiologia , Comorbidade , Serviço Hospitalar de Emergência/estatística & dados numéricos , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , New York , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Sensibilidade e Especificidade
13.
Rev Esp Med Nucl Imagen Mol ; 33(2): 72-8, 2014.
Artigo em Espanhol | MEDLINE | ID: mdl-23938191

RESUMO

OBJECTIVE: The objective of this study was to investigate predictor variables at the moment of normal stress-rest myocardial perfusion gated SPECT for indication of a second gated SPECT. MATERIAL AND METHODS: A prospective, single center cohort study was conducted. We evaluated 2326 consecutive patients (age 63.6 ± 13 years, 57.3% females) without perfusion defects and with normal left ventricular ejection fraction on a myocardial perfusion gated SPECT. Clinical and stress test variables were studied to predict indication of a second gated SPECT and presence of reversible perfusion defects in the second gated SPECT. RESULTS: During a mean follow-up of 3.6 ± 2 years a second gated SPECT was performed in 286 patients (12.3%). Independent predictor variables of a second gated SPECT were presence of three or more cardiovascular risk factors (χ(2): 5.510; HR: 1.4; p=0.019), previous acute myocardial infarction (χ(2): 3.867; HR: 1.4; p=0.049), previous coronary revascularization (χ(2): 41.081; HR: 2.5; p<0.001), and a positive stress test (χ(2): 8.713; HR: 1.5; p=0.003). Observation of perfusion defects in the 280 patients in whom a second stress-rest gated SPECT was performed was more likely in male patients (χ(2): 4.322; HR: 1.9; p=0.038) who had a first pure pharmacological gated-SPECT (χ(2): 7.182; HR: 2.6; p=0.007). CONCLUSIONS: In patients with a first normal myocardial perfusion gated SPECT, various clinical factors and variables derived from the stress test affect the indication of a second gated SPECT and the presence of ischemia in the latter.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Teste de Esforço , Idoso , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/estatística & dados numéricos , Circulação Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos
14.
Ann Nucl Med ; 26(2): 147-63, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22081456

RESUMO

OBJECTIVE: The aim is to compare and evaluate the agreement of quantification of left ventricular functional parameters obtained by two different methods, (99m)Tc-tetrofosmin gated myocardial perfusion SPECT (MPS) and cardiac magnetic resonance imaging (CMR). METHODS: Ten healthy male volunteers participated. Gated MPS data were acquired using 32 frames, which were also combined into 16- and 8-frame data set for the investigation. Gated CMR data were acquired using 8, 16 and 32-frame for the different sets. All examinations were conducted in resting and at exercise conditions. Quantitative measurements of end-diastolic volume (EDV), end-systolic volume (ESV), left ventricular ejection fraction (LVEF), peak ejection rate (PER), peak filling rate (PFR) and time to peak filling (TTPF) were done for each study, respectively. Finally, we evaluated the concordance of parameters between gated MPS and gated CMR by % difference and Bland-Altman plot analysis. RESULTS: LVEF showed favorable concordance in both rest and exercise conditions (% differences were around 10%). PER, PFR and TTPF also showed good concordances in rest conditions, under 32-frame gated collections particularly (% differences were around 10%). In exercise conditions, although the concordances were relatively good, certain variances were noted (% differences were around 20-25%). Regarding left ventricular volumes, the concordance were worse in both conditions (% differences were around 30-40%). CONCLUSIONS: In quantifying of left ventricular function parameter, gated CMR provides similar quantitative values comparing with gated MPS except for ventricular volumes in rest conditions. In contrast, there were certain variations except for LVEF in exercised examinations. When we follow patients by the same cardiac parameters with CMR and MPS, using parameters across the two modalities proved to be possible under rest condition. However, it is limited at exercise condition.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Imageamento por Ressonância Magnética/métodos , Compostos Organofosforados , Compostos de Organotecnécio , Compostos Radiofarmacêuticos , Função Ventricular Esquerda , Adulto , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/estatística & dados numéricos , Teste de Esforço/métodos , Teste de Esforço/estatística & dados numéricos , Humanos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Masculino , Descanso
15.
J Nucl Cardiol ; 18(1): 24-30, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21082299

RESUMO

BACKGROUND: A novel method to quantify dyssynchrony using phase analysis of single-photon emission computed tomography (SPECT) myocardial perfusion imaging has been developed. We sought to determine the prevalence of SPECT-derived mechanical dyssynchrony, and we report clinical variables which predict mechanical dyssynchrony in patients with left ventricular dysfunction. METHODS: We used a count-based Fourier analysis method to convert the regional myocardial counts from discrete frames per cardiac cycle into a continuous thickening function which allows resolution of the phase of the onset of myocardial contraction. The standard deviation of left ventricular phases (Phase SD) describes the regional phase dispersion as a measure of dyssynchrony. Significant dyssynchrony was defined as Phase SD ≥ 43°. 260 patients with left ventricular ejection fraction ≤ 35% were examined. RESULTS: The prevalence of mechanical dyssynchrony in the entire cohort of patients studied was 52%. Univariate predictors of Phase SD were age (P = .03), black race (P = .0005), QRS duration, EF, EDV, summed stress score (SSS), and summed rest score (SRS) (all P = <.0001). Black race, male gender, QRS EF, and SRS were independent predictors of SPECT-based mechanical dyssynchrony. CONCLUSIONS: Significant SPECT-based mechanical dyssynchrony is relatively common among patients with left ventricular dysfunction. In a population of patients with predominantly ischemic heart disease referred for SPECT, a reduced EF, increasing QRS duration, severity and extent of myocardial scar on SPECT imaging are independent predictors of mechanical dyssynchrony and may serve to identify patients for dyssynchrony screening.


Assuntos
Algoritmos , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/estatística & dados numéricos , Interpretação de Imagem Assistida por Computador/métodos , Imagem de Perfusão do Miocárdio/estatística & dados numéricos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/epidemiologia , Idoso , Feminino , Humanos , Aumento da Imagem/métodos , Incidência , Masculino , North Carolina/epidemiologia , Prevalência , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Sensibilidade e Especificidade
16.
Med Phys ; 37(10): 5471-81, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21089783

RESUMO

PURPOSE: In this article, the authors present a motion-compensated spatiotemporal processing algorithm to reduce noise in cardiac gated SPECT. Cardiac gated SPECT data are particularly noisy because the acquired photon data are divided among a number of time frames (gates). Classical spatial reconstruction and processing techniques offer noise reduction but they are usually applied on each frame separately and fail to utilize temporal correlation between frames. METHODS: In this work, the authors present a motion-compensated spatiotemporal postreconstruction filter offering noise reduction while minimizing motion-blur artifacts. The proposed method can be used regardless of the type of image-reconstruction method (analytical or iterative). The between-frame volumetric myocardium motion is estimated using a deformable mesh model based on the model of the myocardial surfaces. The estimated motion is then used to perform spatiotemporal filtering along the motion trajectories. Both the motion-estimation and spatiotemporal filtering methods seek to maintain the wall brightening seen during cardiac contraction. Wall brightening is caused by the partial volume effect, which is usually viewed as an artifact; however, wall brightening is a useful signature in clinical practice because it allows the clinician to visualize wall thickening. Therefore, the authors seek in their method to preserve the brightening effect. RESULTS: The authors find that the proposed method offers better noise reduction than several existing methods as quantitatively evaluated by signal-to-noise ratio, bias-variance plots, and ejection fraction analysis as well as on tested clinical data. CONCLUSIONS: The proposed method mitigates for noise in cardiac gated SPECT images using a postreconstruction motion-compensated filtering approach. Visual as well as quantitative evaluation show considerable improvement in image quality.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/estatística & dados numéricos , Modelos Cardiovasculares , Algoritmos , Fenômenos Biofísicos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Movimento (Física) , Imagens de Fantasmas , Volume Sistólico
17.
J Nucl Med ; 50(2): 226-30, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19164233

RESUMO

UNLABELLED: Early experience is described in implementing a new multimodality stress test for accurate correlation of complementary functional and perfusion information from real-time 3-dimensional (3D) echocardiography and SPECT, respectively. The proposed new multimodality stress test has the potential for simultaneously improving sensitivity and specificity in the detection of early coronary artery disease (CAD). METHODS: Pre- and poststress real-time 3D echocardiography and SPECT images were acquired in 20 patients referred for CAD evaluation and processed using previously developed algorithms for automatic fusion and quantitative analysis of myocardial function and perfusion. All cases of CAD were diagnosed by reviewing quantitatively analyzed fused images, using newly developed software. RESULTS: Real-time 3D echocardiography, SPECT, advance processing, and image review were successfully performed in all 20 patients. Compared with the angiographic findings in 12 patients, diagnosis based on fused images correctly identified 13 of 13 diseased arteries, compared with 11 of 13 identified by SPECT and 6 of 13 identified by echocardiography-based analysis. CONCLUSION: The results suggest the feasibility and potential effectiveness of novel multimodality stress testing.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Ecocardiografia sob Estresse/métodos , Ecocardiografia Tridimensional/métodos , Imagem de Perfusão do Miocárdio/métodos , Idoso , Algoritmos , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/estatística & dados numéricos , Doença da Artéria Coronariana/diagnóstico por imagem , Ecocardiografia sob Estresse/estatística & dados numéricos , Ecocardiografia Tridimensional/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...