Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Braz. J. Pharm. Sci. (Online) ; 58: e19256, 2022. graf
Artigo em Inglês | LILACS | ID: biblio-1374553

RESUMO

Abstract Neuropathic pain is generally characterised by an abnormal sensation (dysesthesia), an increased response to painful stimuli (hyperalgesia), and pain in response to a stimulus that does not normally provoke pain (allodynia). The present study was designed to investigate the effect of trazodone (5mg/kg and 10mg/kg) on peripheral neuropathic pain induced by partial sciatic nerve ligation in rats. Mechanical hyperalgesia, cold allodynia and thermal hyperalgesia were assessed by performing the pinprick, acetone, and hot plate tests, respectively. Biochemically, lipid peroxidation level and total calcium levels were measured. However, trazodone administration (5 and 10 mg/ kg i.p.) for 21days significantly diminished partial sciatic nerve ligation-induced neuropathic pain along with areduction in oxidative stress and calcium levels. The results of the present study suggest that trazodone is effective in attenuating partial sciatic nerve ligation-inducedpainful neuropathic states, which may be attributed to decreased oxidative stress and calcium levels.


Assuntos
Animais , Masculino , Ratos , Dor/classificação , Trazodona/análise , Trazodona/efeitos adversos , Hiperalgesia/classificação , Organização e Administração , Nervo Isquiático/fisiopatologia
2.
Drug Des Devel Ther ; 13: 2283-2293, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31371922

RESUMO

BACKGROUND: Trazodone (TRZ) is a second-generation non-tricyclic antidepressant derived from a triazolopyridine derivative, which is mainly used to treat emotional disorders and conditions related to depressive disorders. PURPOSE: This study investigated the design, development and characteristics of polyvinyl chloride (PVC) membrane sensors for trazodone HCl (TRZ). METHODS: The developed sensing membranes were constructed using ß-cyclodextrin (ß-CD; sensor 1), γ-cyclodextrin (γ-CD; sensor 2) or 4-tert-butylcalix[8]arene (t-BC8; sensor 3) ionophores as sensing materials in addition to ionic sites and dioctyl phthalate in the PVC matrix. RESULTS: Sensors 1, 2 and 3 displayed fast, stable and near-Nernstian response over a relatively wide trazodone concentration range (7.0×10-6-1×10-3, 5.0×10-5-1×10-3and 8.0×10-6-1.0×10-3 M, respectively), with detection limits of 2.2×10-6, 1.5×10-5 and 2.42×10-6 M, respectively in the pH range of 3.0-6.0. The sensors demonstrated good selectivity for TRZ in the presence of different ionic compounds. The accuracy and precision of the proposed sensors were assessed by the determination of 40.7 µg/ml of TRZ, which showed average recoveries of 99.6%, 99.1% and 98.5% with mean relative standard deviations of 2.4%, 2.5% and 2.6% for sensor 1, 2 and 3 respectively. Molecular modeling was used to calculate the host-guest binding energy. The lowest free binding energy was -6.243, -5.752 and -5.7105 kcal/mol for 1:1 stoichiometry host-guest complexes of trazodone and ß-CD, γ-CD and t-BC8, respectively, which was in-line with a Nernstian response. CONCLUSION: The investigated methods can be applied for the determination of TRZ in pharmaceutical preparations. The results of investigated dosage-form of TRZ show good agreement with those using the US Pharmacopeia method.


Assuntos
Técnicas Biossensoriais , Calixarenos/química , Ionóforos/química , Trazodona/análise , Trazodona/química , beta-Ciclodextrinas/química , gama-Ciclodextrinas/química , Estrutura Molecular
3.
Ann Pharm Fr ; 77(4): 286-294, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31027753

RESUMO

OBJECTIVES: Elderly people with dementia are commonly suffered from sleep disorders. So, the use of Donepezil hydrochloride as anti-Alzheimer drug and Trazodone hydrochloride as antidepressants with hypnotic action is very important in these cases. This study reports about novel and sensitive RP-HPLC method with fluorescence detection for simultaneous bioanalytical determination of Donepezil hydrochloride (DON) and co-administered, Trazodone hydrochloride (TRA) in their pure forms, spiked human plasma and tablets. MATERIALS AND METHODS: Elution of both drugs was achieved with excellent resolution using a RP-C18 Hypersil Gold column and an isocratic mobile phase consisting of phosphate buffer (50mm, pH 4.6): methanol: acetonitrile (60:35:5) with a flow rate of 1.5mL/min and 20µL as injection volume. A Fluorescence detector at 300nm for excitation and 400nm for emission was used. RESULTS: Retention times were 4.3 and 6.3min for Donepezil hydrochloride and Trazodone hydrochloride, respectively. Linearity ranges of the assay were 25-1000 and 50-5000ng/mL and the limits of detection (LOD) and quantitation (LOQ) were 8.52, 15.47 and 25.81, 46.89ng/mL for Donepezil hydrochloride and Trazodone hydrochloride, respectively. CONCLUSION: The high sensitivity of the proposed method enabled the successful determination of the cited drugs in spiked human plasma with mean percentage of recoveries of 91.58±3.34 and 100.30±5.11 for Donepezil hydrochloride and Trazodone hydrochloride, respectively.


Assuntos
Antidepressivos de Segunda Geração/análise , Inibidores da Colinesterase/análise , Donepezila/análise , Trazodona/análise , Antidepressivos de Segunda Geração/sangue , Inibidores da Colinesterase/sangue , Cromatografia Líquida de Alta Pressão , Donepezila/sangue , Humanos , Indicadores e Reagentes , Limite de Detecção , Reprodutibilidade dos Testes , Espectrometria de Fluorescência , Comprimidos , Trazodona/sangue
4.
Electrophoresis ; 39(9-10): 1301-1308, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29427324

RESUMO

Environmental contamination with pharmaceuticals has received growing attention in recent years. Several studies describe the presence of traces of drugs in water bodies and soils and their impacts on nontarget organisms including plants. Due to these facts investigations of the uptake and metabolism of pharmaceuticals in organisms is an emerging research area. The present study demonstrates the analysis of three selected antidepressants (sertraline, clomipramine, and trazodone) as well as metabolites and transformation products in a cress model (Lepidium sativum). Cress was treated with tap water containing 10 mg/L of the parent drugs. Employing an analytical approach based on high performance liquid chromatography coupled with quadrupole time of flight or Orbitrap mass spectrometry in MS and MS² modes, in total 14 substances were identified in the cress extracts. All three parent drugs were taken up by the cress and translocated from the roots to the leaves in specific patterns. In addition to this, eleven metabolite species were identified. They were generated by hydroxylation, demethylation, conjugation with amino acids, or combinations of these mechanisms. Finally, the inclusion of control cultures in the experimental setup allowed for a differentiation of "true" metabolites generated by the cress and transformation products generated by plant-independent mechanisms.


Assuntos
Clomipramina/metabolismo , Lepidium sativum/metabolismo , Sertralina/metabolismo , Espectrometria de Massas em Tandem/métodos , Trazodona/metabolismo , Antidepressivos/análise , Antidepressivos/metabolismo , Cromatografia Líquida de Alta Pressão , Clomipramina/análise , Metaboloma , Folhas de Planta/química , Folhas de Planta/metabolismo , Raízes de Plantas/química , Raízes de Plantas/metabolismo , Sertralina/análise , Trazodona/análise
5.
Luminescence ; 32(7): 1240-1245, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28422449

RESUMO

A new sensitized chemiluminescence method by acidic permanganate oxidation was developed for the sensitive determination of trazodone. A fluorescent dye as used rhodamine 6G to increase a chemiluminescence intensity. Under optimum conditions, the liner range of the calibration curve was obtained for 1-5000 nmol/L. The limit of detection was calculated from 3σ of a blank was 0.23 nmol/L. The coexistent ions and substances had no interference with the chemiluminescence measurement. The chemiluminescence spectra were measured to elucidate a possible mechanism for the system. The present method was satisfactorily used in the determination of the drugs in pharmaceutical samples and animal serums.


Assuntos
Medições Luminescentes/métodos , Rodaminas/química , Trazodona/análise , Animais , Calibragem , Corantes Fluorescentes , Cinética , Limite de Detecção , Compostos de Manganês/química , Oxirredução , Óxidos/química , Comprimidos/análise , Trazodona/sangue , Trazodona/química
6.
J Anal Toxicol ; 40(4): 243-7, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26945835

RESUMO

Alternative specimens have been occasionally considered as substitutes for whole blood for postmortem toxicology testing. We studied the applicability of vitreous humor, and evaluated whether it would be suitable to replace (or augment) whole blood for routine drug screening. Results showed that from 51 autopsy cases, we were able to identify an aggregate of 209 findings in whole blood compared with 169 in vitreous. The total number of compounds identified was 71 for whole blood and 60 for vitreous humor. Quantitative analysis showed that whole-blood concentrations of trazodone were several fold higher than vitreous humor concentrations (1.42 ± 0.57 vs. 0.15 ± 0.05 mg/L, respectively) and similar results were also obtained for diazepam (0.37 ± 0.06 vs. 0.13 ± 0.01, respectively). For other drugs such as oxycodone, hydrocodone and doxylamine, a trend suggesting higher concentrations in vitreous humor vs. whole blood was observed; however, this was not significant. Our results are consistent with the limited work of other investigators, and suggest that vitreous humor could be an appropriate matrix for drug screening in postmortem toxicology.


Assuntos
Toxicologia Forense/métodos , Preparações Farmacêuticas/análise , Corpo Vítreo/química , Antidepressivos de Segunda Geração/análise , Autopsia , Análise Química do Sangue , Diazepam/análise , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Reprodutibilidade dos Testes , Detecção do Abuso de Substâncias , Trazodona/análise
7.
Forensic Sci Int ; 251: 195-201, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25912183

RESUMO

Non-toxic postmortem trazodone tissue (liver) concentrations have not been previously described. Liver trazodone concentrations were compared to peripheral blood and central blood concentrations in 19 medical examiner cases. Postmortem blood specimens were initially screened for alcohol and simple volatiles, drugs of abuse, and alkaline drugs. Trazodone, when detected by the alkaline drug screen, was subsequently confirmed and quantified by a high performance liquid chromatography procedure. Re-analyses showed that there may be degradation of trazodone in postmortem blood stored at 4°C. There was, on average, about a 20% decrease in samples stored up to eight months. These data suggest that postmortem trazodone peripheral blood concentrations may be considered non-toxic to at least 1.0mg/L with liver concentrations to at least 2.2mg/kg. Overall, trazodone concentrations ranged from 0.08-6.1mg/L in peripheral blood, 0.07-7.1mg/L in central blood, and 0.39-26mg/kg in liver. The median trazodone central blood to peripheral blood ratio was 0.98 (N=19). The liver to peripheral blood ratios showed a median value of 2.8L/kg (N=18). Given that a liver to peripheral blood ratio less than 5L/kg is consistent with little to no propensity for postmortem redistribution, these data demonstrate that trazodone is unlikely to show significant redistribution.


Assuntos
Mudanças Depois da Morte , Inibidores Seletivos de Recaptação de Serotonina/farmacocinética , Trazodona/farmacocinética , Adulto , Cromatografia Líquida , Feminino , Toxicologia Forense , Humanos , Fígado/química , Masculino , Pessoa de Meia-Idade , Inibidores Seletivos de Recaptação de Serotonina/análise , Manejo de Espécimes , Distribuição Tecidual , Trazodona/análise , Adulto Jovem
8.
Talanta ; 79(2): 361-8, 2009 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-19559891

RESUMO

A simple and rapid electrochemical method was developed for the determination of trace-level trazodone, based on the excellent properties of multi-walled carbon nanotubes (MWCNTs). The MWCNT-modified glassy carbon electrode was constructed and the electrochemical behavior of trazodone was investigated in detail. The cyclic voltammetric results indicate that MWCNT-modified glassy carbon electrode can remarkably enhance electrocatalytic activity towards the oxidation of trazodone in neutral solutions. It leads to a considerable improvement of the anodic peak current for trazodone, and allows the development of a highly sensitive voltammetric sensor for the determination of trazodone. Trazodone could effectively accumulate at this electrode and produce two anodic peaks at about 0.73 V and 1.00 V. The electrocatalytic behavior was further exploited as a sensitive detection scheme for the trazodone determination by differential-pulse voltammetry. Under optimized conditions, the concentration range and detection limit are 0.2-10 microM and 24 nM, respectively for trazodone. The proposed method was successfully applied to trazodone determination in pharmaceutical samples. The analytical performance of this sensor has been evaluated for detection of analyte in urine as a real sample.


Assuntos
Técnicas Eletroquímicas/instrumentação , Trazodona/análise , Carbono , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/normas , Eletrodos/normas , Humanos , Nanotubos de Carbono , Oxirredução , Preparações Farmacêuticas/análise , Inibidores Seletivos de Recaptação de Serotonina/análise , Inibidores Seletivos de Recaptação de Serotonina/urina , Trazodona/urina
9.
J Pharm Biomed Anal ; 49(4): 1082-7, 2009 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-19237257

RESUMO

A specific liquid chromatography-mass spectrometric (LC-MS) method using an ion trap spectrometer was developed for the quantitation of articaine in human plasma. Articaine and the internal standard (trazodone) were extracted in a single step with diethyl-ether from 0.5 mL of alkalinized plasma. The mobile phase consisted of acetonitrile with 0.1% formic acid (40:60, v/v). It was delivered at a flow rate of 0.3 mL/min. The effluent was monitored by MS in positive-ion mode. Ionisation was performed using an electrospray ion source operating at 200 degrees C. Articaine was identified and quantified in SIM mode at m/z 185. Calibration curves were linear over the concentration range of 78.1-5000 ng/mL with determination coefficients>0.996. This method was fast (total run-time<3 min), accurate (bias<16%), and reproducible (intra-assay and inter-assay precision<14%) with a quantitation limit of 78.1 ng/mL. The good specificity and sensitivity achieved by this method allowed the determination of articaine plasma levels in patients following a submucosal infiltration injection of articaine in the patients undergoing a third molar surgery.


Assuntos
Anestésicos Locais/sangue , Carticaína/sangue , Anestésicos Locais/farmacocinética , Anestésicos Locais/uso terapêutico , Antidepressivos de Segunda Geração/análise , Calibragem , Carticaína/farmacocinética , Carticaína/uso terapêutico , Cromatografia Líquida de Alta Pressão , Humanos , Indicadores e Reagentes , Dente Serotino , Dor Pós-Operatória/tratamento farmacológico , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray , Extração Dentária , Trazodona/análise
10.
Anal Bioanal Chem ; 394(6): 1563-7, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19238364

RESUMO

A trazodone-selective electrode for application in pharmaceutical quality control and urine analysis was developed. The electrode is based on incorporation of a trazodone-tetraphenylborate ion exchanger in a poly(vinyl chloride) membrane. The electrode showed a fast, stable and Nernstian response over a wide trazodone concentration range (5 x 10(-5)-1 x 10(-2) M) with a mean slope of 59.3 +/- 0.9 mV/dec of concentration, a mean detection limit of 1.8 x 10(-5) +/- 2.2 x 10(-6) M, a wide working pH range (5-7.5) and a fast response time (less than 20 s). The electrode also showed good accuracy, repeatability, reproducibility and selectivity with respect to some inorganic and organic compounds, including the main trazodone metabolite. The electrode provided good analytical results in the determination of trazodone in pharmaceuticals and spiked urine samples; no extraction steps were necessary. Dissolution testing of trazodone tablets, in different conditions of pH and particle size, based on a direct potentiometric determination with the new selective electrode is presented as well.


Assuntos
Preparações Farmacêuticas/química , Trazodona/análise , Urinálise/instrumentação , Eletrodos , Humanos , Concentração de Íons de Hidrogênio , Controle de Qualidade , Trazodona/urina
11.
Av. odontoestomatol ; 24(5): 313-321, sept.-oct.. 2008.
Artigo em Es | IBECS | ID: ibc-68081

RESUMO

El síndrome de boca ardiente (SBA) es una entidad patológica caracterizada por la presencia de síntomas crónicos de ardor o dolor en la mucosa bucal clínicamente normal. El SBA afecta principalmente a mujeres peri y posmenopáusicas. Su causa es desconocida, pero su relación con una compleja asociación de factores biológicos y psicológicos hace suponer una etiología multifactorial. Aunque se han encontrado tratamientos eficaces en casos particulares, se sigue buscando un tratamiento que resulte eficaz en la mayoría de los casos. Esta revisión hace especial referencia a los factores etiológicos y al tratamiento del síndrome (AU)


The burning mouth syndrome (BMS) is characterized by the presence of chronic symptoms of burning or paining clinically normal oral mucosa. This syndrome primarily affects peri and postmenopausal women. The cause is unknown, but the relationship between the BMS and a complex association of biological and psychological factors suggest a multifactorial etiology. Although some treatments have been found effective in particular cases, the clinical searchers are still looking for a treatment that can be effective in most cases. This review makes particular reference to the etiological factors and the treatment of the síndrome (AU)


Assuntos
Humanos , Masculino , Feminino , Síndrome da Ardência Bucal/diagnóstico , Síndrome da Ardência Bucal/terapia , Mucosa Bucal , Mucosa Bucal/patologia , Glossalgia/complicações , Glossalgia/terapia , Capsaicina/uso terapêutico , Clonazepam/uso terapêutico , Síndrome da Ardência Bucal/complicações , Síndrome da Ardência Bucal/epidemiologia , Síndrome da Ardência Bucal/fisiopatologia , Síndrome da Ardência Bucal/radioterapia , Candidíase Bucal/complicações , Trazodona/análise , Trazodona/uso terapêutico
13.
J Chromatogr A ; 1156(1-2): 254-8, 2007 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-17451726

RESUMO

A simple and reliable liquid chromatographic procedure is described for the determination of trazodone in pharmaceutical formulations and urine samples. The optimized procedure uses fluorimetric detection, a C18 column and a micellar mobile phase of sodium dodecyl sulfate (SDS) and 1-butanol. The mobile phase selected for use was 0.2M SDS and 8% 1-butanol fixed at pH 3 with phosphate buffer. The total analysis time was 10 min. For the analysis of urine samples, one great advantage of the method is that no extraction step is required. The quantification limit was 9.5 ng mL(-1), ensuring the analysis of the drug in biological fluids. The procedure shows good accuracy, repeatability and selectivity. Repeatability and intermediate precision were tested for several concentrations of the drug. Good claim percentages were obtained in the analysis of pharmaceutical formulations. Calibration repeatability in urine matrix was also studied in the 0.06-22.4 microg mL(-1) range. Good recoveries were obtained from spiked urine samples. No interferences from common additives frequently administered with trazodone or from endogenous compounds in urine samples were found. The results show that the procedure is suitable for routine analysis of the drug.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Trazodona/análise , Trazodona/urina , Humanos , Micelas , Espectrometria de Fluorescência
14.
Spectrochim Acta A Mol Biomol Spectrosc ; 68(5): 1244-9, 2007 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-17376736

RESUMO

A simple and rapid spectrophotometric method has been developed for the determination of tricyclic anti-depressant drugs such as trazodone (TZH), amineptine (APH) and amitriptyline (ATPH) hydrochlorides in pure form and in different pharmaceutical preparations. The charge transfer (CT) reaction between TZH, APH and ATPH as electron donors and TCNQ as electron acceptor was utilized for their spectrophotometric determination. The optimum experimental conditions, like time, temperature, stoichiometry, solvents, for the CT complex formation are established. The method permits the determination of TZH, APH and ATPH over a concentration range of 10-400, 10-440 and 10-300 microg ml(-1), respectively. The sensitivity (S) is found to be 0.09, 0.087 and 0.069 g cm(-2) for TZH, APH and ATPH, respectively. The SD values are found to be 0.146-0.293, 0.154-0.285 and 0.091-0.212 and RSD values are 0.142-1.92, 0.297-1.92 and 0.212-0.915 for TZH, APH and ATPH, respectively. The low values of the relative standard deviation indicate the high accuracy and precision of the method. The mean recovery values obtained together with a high correlation coefficient values, amount in the range 98-101.5, 98.7-102.9 and 93-101.9 for TZH, APH and ATPH, respectively. The method is applicable for the assay of the investigated drugs in different dosage forms and the results are in good agreement with those obtained by the official method.


Assuntos
Amitriptilina/análise , Antidepressivos Tricíclicos/análise , Dibenzocicloeptenos/análise , Nitrilas/química , Trazodona/análise , Amitriptilina/química , Antidepressivos Tricíclicos/química , Dibenzocicloeptenos/química , Preparações Farmacêuticas/química , Solventes , Espectrofotometria , Temperatura , Fatores de Tempo , Trazodona/química
15.
Anal Chim Acta ; 587(1): 75-81, 2007 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-17386756

RESUMO

A novel micro-extraction procedure was developed through the use of an electrospun polymer nanofiber as a solid-phase extraction (SPE) sorbent to directly extract trazodone from human plasma. The target compound was then monitored by a high performance liquid chromatography with ultraviolet detector (HPLC-UV) system. Parameters of influencing the extraction efficiency, such as fiber diameter, fiber packing amount, eluted solvent, pH and ionic strength were investigated. Under the optimized conditions, a linear response for trazodone over the range of 20-2000 ng mL(-1) was achieved with a gamma(2) value of 0.9996. The precision of the method was examined with relative standard deviations of 5.7, 2.7, 2.2% corresponding to 50, 200, and 500 ng mL(-1), respectively, of trazodone spiked into 0.1 mL of plasma samples. The extraction recoveries of 58.3-75.2% and the relative recoveries of 94.6-105.5% were obtained. The limit of detection (LOD) was determined to be 8 ng mL(-1). A 15 min of HPLC gradient was successfully applied to determine trazodone from human plasma. Due to its simplicity, selectivity and sensitivity, the method may be applied to pharmacokinetic and pharmacodynamic studies of drugs.


Assuntos
Antidepressivos de Segunda Geração/sangue , Antidepressivos de Segunda Geração/farmacocinética , Análise Química do Sangue/métodos , Eletroquímica/métodos , Polímeros/química , Extração em Fase Sólida/métodos , Trazodona/sangue , Trazodona/farmacocinética , Absorção , Antidepressivos de Segunda Geração/análise , Calibragem , Cromatografia Líquida de Alta Pressão/métodos , Humanos , Concentração de Íons de Hidrogênio , Íons , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrofotometria Ultravioleta/métodos , Trazodona/análise
16.
Am J Forensic Med Pathol ; 28(1): 55-8, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17325466

RESUMO

A fatal suicidal ingestion of drugs, together with activated charcoal, is reported. The death occurred 31 hours after the self-administration. The autopsy revealed a large amount of gastric content that appeared to be a compact mass of black color. Toxicologic analyses showed the presence of toxic levels of desalkylflurazepam and trazodone; metamizole and pridinol were also detected. The obtained results supported the hypothesis of a death due to acute intoxication delayed by the self-administration of activated charcoal, which elimination was probably hindered by the action of pridinol.


Assuntos
Antídotos/administração & dosagem , Carvão Vegetal/administração & dosagem , Suicídio , Idoso , Ansiolíticos/análise , Ansiolíticos/intoxicação , Anti-Inflamatórios não Esteroides/análise , Anti-Inflamatórios não Esteroides/intoxicação , Dipirona/análise , Dipirona/intoxicação , Overdose de Drogas , Feminino , Flurazepam/análogos & derivados , Flurazepam/análise , Flurazepam/intoxicação , Toxicologia Forense , Cromatografia Gasosa-Espectrometria de Massas , Conteúdo Gastrointestinal/química , Humanos , Métodos , Piperidinas/análise , Piperidinas/intoxicação , Trazodona/análise , Trazodona/intoxicação
17.
Chem Pharm Bull (Tokyo) ; 54(7): 968-71, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16819213

RESUMO

Two simple, rapid and sensitive extractive spectrophotometric methods have been developed for the assay of trazodone hydrochloride (TRH) in pure and pharmaceutical formulations. These methods are based on the formation of chloroform soluble ion-association complexes of TRH with bromothymol blue (BTB) and with bromocresol purple (BCP) in KCl-HCl buffer of pH 2.0 (for BTB) and in NaOAc-AcOH buffer of pH of 3.6 (for BCP) with absorption maximum at 423 nm and at 408 nm for BTB and BCP, respectively. Reaction conditions were optimized to obtain the maximum color intensity. The absorbance was found to increase linearly with increase in concentration of TRH, which was corroborated by the calculated correlation coefficient values (0.9996, 0.9945). The systems obeyed Beer's law in the range of 0.2-14.5 and 0.2-14.1 microg/ml for BTB and BCP, respectively. Various analytical parameters have been evaluated and the results have been validated by statistical data. No interference was observed from common excipients present in pharmaceutical formulations. The proposed methods are simple, accurate and suitable for quality control applications.


Assuntos
Preparações Farmacêuticas/química , Espectrofotometria/métodos , Trazodona/análise , Antidepressivos de Segunda Geração/análise , Púrpura de Bromocresol/química , Azul de Bromotimol/química , Indicadores e Reagentes/química , Estrutura Molecular , Solubilidade , Trazodona/química
18.
Clin Chim Acta ; 366(1-2): 352-6, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16406032

RESUMO

BACKGROUND: Amino acid neurotransmitters represent a major class of compounds that are involved in neuronal communication at CNS synapses. METHODS: Twelve amino acids were separated after precolumn derivatization with dansyl chloride. The biologically important amino acids, taurine, aspartate, glutamate, glycine, alanine and gamma-aminobutyric acid were determined in rat brain tissue and rabbit plasma. RESULTS: The major modifications to previous methods included isocratic elution instead of gradient elution to reduce time and cost of serial analyses; optimization of mobile phase to improve the separation of free dansyl with derivatives, so as to elide complex steps for the clean of the chromatogram; and selection of an internal standard (Trazodone) to improve the reproducibility and the reliability of procedures. Twelve amino acids were assayed within 35 min. Other alpha-amino acids that are relevant to the make-up of mammalian proteins did not interfere with the determination. The standard curve, recovery, analytical precision and detection limits for each neuroactive amino acid were determined. CONCLUSION: This assay separated 12 amino acids in a single run. Six neuroactive amino acids were also simultaneous measured by isocratic HPLC with UV detection. The method is applicable in determination of Tau, Glu, Asp, Gly, Ala and GABA in biological samples.


Assuntos
Aminoácidos/análise , Cromatografia Líquida de Alta Pressão/métodos , Compostos de Dansil/química , Alanina/análise , Alanina/química , Aminoácidos/sangue , Aminoácidos/química , Animais , Ácido Aspártico/análise , Ácido Aspártico/química , Química Encefálica , Ácido Glutâmico/análise , Ácido Glutâmico/química , Glicina/análise , Glicina/química , Coelhos , Ratos , Padrões de Referência , Reprodutibilidade dos Testes , Espectrofotometria Ultravioleta/métodos , Taurina/análise , Taurina/química , Trazodona/análise , Trazodona/normas , Ácido gama-Aminobutírico/análise , Ácido gama-Aminobutírico/química
19.
J Pharm Biomed Anal ; 39(3-4): 705-11, 2005 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-15935603

RESUMO

ZD6474 (N-(4-Bromo-2-fluorophenyl)-6-methoxy-7-[(1-methylpiperidin-4-yl)methoxy] quinazolin-4-amine) is a tyrosine kinase inhibitor with anti-angiogenic and anti-tumor activity that is currently undergoing human trials for cancer treatment. Pharmacokinetic studies in animal models are an important component in clinical development of this agent to relate pre-clinical models to patient treatment. A liquid chromatography tandem mass spectrometry method was developed for the determination of ZD6474 levels in mouse plasma and tissues. Plasma (0.05 mL) and tissue homogenates (0.1 mL of 10 mg/mL) were extracted under alkaline conditions with ethyl acetate:pentane (1:1, v/v) after addition of the internal standard (trazodone, 2-[3-[4-(3-chlorophenyl)-1-piperazinyl]propyl]-1,2,4-triazolo[4,3-a]pyridine-3(2H)-one). Separation was achieved on a C18, 50 mm x 2 mm column with quantitation by internal standard reference and multiple reaction monitoring of the ion transitions m/z 475-->112 (ZD6474) and m/z 372-->176 (trazodone). The calibration curve was linear from a range spanning 20-20,000 ng/mL in plasma and 10-320 ng/mg in tissue homogenates. Mean recoveries from plasma and tissue homogenates were 88 and 90%, respectively. The accuracy in plasma was 88% at the lower limit of quantitation (20 ng/mL with a 50 microL plasma sample) with high precision (R.S.D.%<10%). Assay performance in liver and other tissue homogenates is also reported. The assay was applied to a pharmacokinetic study in mice to determine dosing schedules that would approximate therapeutic ZD6474 levels determined in humans.


Assuntos
Química Farmacêutica/métodos , Cromatografia Líquida/métodos , Ensaios de Seleção de Medicamentos Antitumorais/métodos , Espectrometria de Massas/métodos , Neoplasias/tratamento farmacológico , Piperidinas/análise , Piperidinas/farmacocinética , Quinazolinas/análise , Quinazolinas/farmacocinética , Acetatos/análise , Animais , Antineoplásicos/farmacologia , Calibragem , Cromatografia/métodos , Inibidores Enzimáticos/farmacologia , Feminino , Humanos , Íons , Fígado/efeitos dos fármacos , Fígado/metabolismo , Camundongos , Camundongos Endogâmicos BALB C , Modelos Químicos , Pentanos/análise , Piperidinas/química , Proteínas Tirosina Quinases/antagonistas & inibidores , Quinazolinas/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo , Distribuição Tecidual , Trazodona/análise
20.
Pharm Res ; 21(1): 177-84, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14984273

RESUMO

PURPOSE: The purpose of this study was to establish an automated approach to salt selection and to search for unique trazodone salts for new applications. METHODS: Automated procedures were developed on a Biomek 2000 automation workstation with stacker and plate reader capabilities. Trazodone was dispensed into 96-well plates, and an automated method was set up to form 104 trazodone salts. Salts were observed under a polarized light microscope to determine crystallinity. After stepwise eliminations, the remaining salts were scaled-up and subjected to differential scanning calorimetry (DSC), powder x-ray diffraction (PXRD), hygroscopic, pH-solubility, density, surface area, and particle size analyses. RESULTS: Oils formed in several cases resulting in preliminary elimination of mesyl and esyl salts and four crystallizing solvents. Crystallinity was observed in 34 of 44 scaled-up trazodone salts. PXRD, DSC, and hygroscopic analyses indicated a number of new salts that were comparable in physicochemical parameters to the marketed HCl salt. Among them, the tosylate salt showed uniqueness for new applications. CONCLUSIONS: Automated procedures can be developed to increase the efficiency of pharmaceutical salt selection. The new tosylate salt gave a unique pH-solubility profile with low solubility over the entire pH range making it a potential candidate for a suspension or prolonged action formulation.


Assuntos
Sais/química , Trazodona/química , Concentração de Íons de Hidrogênio , Tamanho da Partícula , Pós , Sais/análise , Solubilidade , Trazodona/análise , Difração de Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...