Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.967
Filtrar
1.
Crit Care ; 28(1): 245, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39014512

RESUMO

BACKGROUND: In mechanically ventilated patients, diaphragm ultrasound can identify diaphragm weakness and predict weaning failure. We evaluated whether a novel operator-independent ultrasound-based medical device allowing continuous monitoring of the diaphragm (CUSdi) could reliably (1) measure diaphragm excursion (EXdi) and peak contraction velocity (PCVdi), (2) predict weaning outcome, and (3) approximate transdiaphragmatic pressure (Pdi). METHODS: In 49 mechanically ventilated patients, CUSdi was recorded during a 30-min spontaneous breathing trial (SBT), and EXdi and PCVdi were measured. In subgroups of patients, standard ultrasound measurement of EXdi and PCVdi was performed (n = 36), and Pdi derived parameters (peak and pressure time product, n = 30) were measured simultaneously. RESULTS: The agreement bias between standard ultrasound and CUSdi for EXdi was 0.1 cm (95% confidence interval -0.7-0.9 cm). The regression of Passing-Bablok indicated a lack of systematic difference between EXdi measured with standard ultrasound and CUSdi, which were positively correlated (Rho = 0.84, p < 0.001). Weaning failure was observed in 54% of patients. One, two and three minutes after the onset of the SBT, EXdi was higher in the weaning success group than in the failure group. Two minutes after the onset of the SBT, an EXdi < 1.1 cm predicted weaning failure with a sensitivity of 0.83, a specificity of 0.68, a positive predictive value of 0.76, and a negative predictive value of 0.24. There was a weak correlation between EXdi and both peak Pdi (r = 0.22, 95% confidence interval 0.15 - 0.28) and pressure time product (r = 0.13, 95% confidence interval 0.06 - 0.20). Similar results were observed with PCVdi. CONCLUSIONS: Operator-independent continuous diaphragm monitoring quantifies EXdi reliably and can predict weaning failure with an identified cut-off value of 1.1 cm. Trial registration clinicaltrial.gov, NCT04008875 (submitted 12 April 2019, posted 5 July 2019) and NCT03896048 (submitted 27 March 2019, posted 29 March 2019).


Assuntos
Diafragma , Ultrassonografia , Desmame do Respirador , Humanos , Desmame do Respirador/métodos , Desmame do Respirador/normas , Diafragma/diagnóstico por imagem , Diafragma/fisiopatologia , Estudos Prospectivos , Masculino , Feminino , Ultrassonografia/métodos , Ultrassonografia/normas , Pessoa de Meia-Idade , Idoso , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Respiração Artificial/métodos , Valor Preditivo dos Testes
2.
J Med Internet Res ; 26: e51397, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38963923

RESUMO

BACKGROUND: Machine learning (ML) models can yield faster and more accurate medical diagnoses; however, developing ML models is limited by a lack of high-quality labeled training data. Crowdsourced labeling is a potential solution but can be constrained by concerns about label quality. OBJECTIVE: This study aims to examine whether a gamified crowdsourcing platform with continuous performance assessment, user feedback, and performance-based incentives could produce expert-quality labels on medical imaging data. METHODS: In this diagnostic comparison study, 2384 lung ultrasound clips were retrospectively collected from 203 emergency department patients. A total of 6 lung ultrasound experts classified 393 of these clips as having no B-lines, one or more discrete B-lines, or confluent B-lines to create 2 sets of reference standard data sets (195 training clips and 198 test clips). Sets were respectively used to (1) train users on a gamified crowdsourcing platform and (2) compare the concordance of the resulting crowd labels to the concordance of individual experts to reference standards. Crowd opinions were sourced from DiagnosUs (Centaur Labs) iOS app users over 8 days, filtered based on past performance, aggregated using majority rule, and analyzed for label concordance compared with a hold-out test set of expert-labeled clips. The primary outcome was comparing the labeling concordance of collated crowd opinions to trained experts in classifying B-lines on lung ultrasound clips. RESULTS: Our clinical data set included patients with a mean age of 60.0 (SD 19.0) years; 105 (51.7%) patients were female and 114 (56.1%) patients were White. Over the 195 training clips, the expert-consensus label distribution was 114 (58%) no B-lines, 56 (29%) discrete B-lines, and 25 (13%) confluent B-lines. Over the 198 test clips, expert-consensus label distribution was 138 (70%) no B-lines, 36 (18%) discrete B-lines, and 24 (12%) confluent B-lines. In total, 99,238 opinions were collected from 426 unique users. On a test set of 198 clips, the mean labeling concordance of individual experts relative to the reference standard was 85.0% (SE 2.0), compared with 87.9% crowdsourced label concordance (P=.15). When individual experts' opinions were compared with reference standard labels created by majority vote excluding their own opinion, crowd concordance was higher than the mean concordance of individual experts to reference standards (87.4% vs 80.8%, SE 1.6 for expert concordance; P<.001). Clips with discrete B-lines had the most disagreement from both the crowd consensus and individual experts with the expert consensus. Using randomly sampled subsets of crowd opinions, 7 quality-filtered opinions were sufficient to achieve near the maximum crowd concordance. CONCLUSIONS: Crowdsourced labels for B-line classification on lung ultrasound clips via a gamified approach achieved expert-level accuracy. This suggests a strategic role for gamified crowdsourcing in efficiently generating labeled image data sets for training ML systems.


Assuntos
Crowdsourcing , Pulmão , Ultrassonografia , Crowdsourcing/métodos , Humanos , Ultrassonografia/métodos , Ultrassonografia/normas , Pulmão/diagnóstico por imagem , Estudos Prospectivos , Feminino , Masculino , Aprendizado de Máquina , Adulto , Pessoa de Meia-Idade , Estudos Retrospectivos
3.
Crit Care ; 28(1): 224, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38978055

RESUMO

BACKGROUND: Acute respiratory distress syndrome (ARDS) is a life-threatening respiratory condition with high mortality rates, accounting for 10% of all intensive care unit admissions. Lung ultrasound (LUS) as diagnostic tool for acute respiratory failure has garnered widespread recognition and was recently incorporated into the updated definitions of ARDS. This raised the hypothesis that LUS is a reliable method for diagnosing ARDS. OBJECTIVES: We aimed to establish the accuracy of LUS for ARDS diagnosis and classification of focal versus non-focal ARDS subphenotypes. METHODS: This systematic review and meta-analysis used a systematic search strategy, which was applied to PubMed, EMBASE and cochrane databases. Studies investigating the diagnostic accuracy of LUS compared to thoracic CT or chest radiography (CXR) in ARDS diagnosis or focal versus non-focal subphenotypes in adult patients were included. Quality of studies was evaluated using the QUADAS-2 tool. Statistical analyses were performed using "Mada" in Rstudio, version 4.0.3. Sensitivity and specificity with 95% confidence interval of each separate study were summarized in a Forest plot. RESULTS: The search resulted in 2648 unique records. After selection, 11 reports were included, involving 2075 patients and 598 ARDS cases (29%). Nine studies reported on ARDS diagnosis and two reported on focal versus non-focal ARDS subphenotypes classification. Meta-analysis showed a pooled sensitivity of 0.631 (95% CI 0.450-0.782) and pooled specificity of 0.942 (95% CI 0.856-0.978) of LUS for ARDS diagnosis. In two studies, LUS could accurately differentiate between focal versus non-focal ARDS subphenotypes. Insufficient data was available to perform a meta-analysis. CONCLUSION: This review confirms the hypothesis that LUS is a reliable method for diagnosing ARDS in adult patients. For the classification of focal or non-focal subphenotypes, LUS showed promising results, but more research is needed.


Assuntos
Pulmão , Síndrome do Desconforto Respiratório , Ultrassonografia , Humanos , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Síndrome do Desconforto Respiratório/classificação , Ultrassonografia/métodos , Ultrassonografia/normas , Pulmão/diagnóstico por imagem , Fenótipo
4.
Crit Care ; 28(1): 197, 2024 06 11.
Artigo em Inglês | MEDLINE | ID: mdl-38858766

RESUMO

Though the novel venous excess ultrasound (VExUS) score is increasingly used as a noninvasive means of venous congestion measurement, the inter-rater reliability (IRR), inter-user reproducibility (IUR), and utility of concurrent ECG have not been evaluated. We conducted a multicenter study of the IRR, IUR, and utility of ECG for VExUS interpretation between four attending physicians of diverse specialties, reporting the Kappa statistic (KS) and Intraclass Correlation Coefficient (ICC) for IRR and IUR for scans with and without ECG. Eighty-four paired VExUS exams from 42 patients, 60 of which had a concurrent ECG tracing, were interpreted. They showed substantial IRR, with a KS of 0.71 and ICC of 0.83 for the overall VExUS grade (p < 0.001), and IUR, with a KS 0.63 and ICC of 0.8. There was greater agreement among images with an ECG tracing. These results suggest that ECG-augmented VExUS may be a reliable and reproducible measure interpretable by clinicians with diverse backgrounds.


Assuntos
Ultrassonografia , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Feminino , Masculino , Pessoa de Meia-Idade , Ultrassonografia/métodos , Ultrassonografia/normas , Idoso , Hiperemia/diagnóstico por imagem , Adulto , Eletrocardiografia/métodos
5.
J Med Ultrason (2001) ; 51(3): 483-489, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38842643

RESUMO

BACKGROUND: Patients with suspected ramp lesions on magnetic resonance imaging (MRI) or ultrasonography (US) healed and showed no instability based on intraoperative arthroscopic findings. The purpose of this study was to assess the use of US in evaluating ramp lesions preoperatively and intraoperatively. METHODS: Eighty-two knees that underwent anterior cruciate ligament (ACL) reconstruction between January 2022 and June 2023 were included to assess the ramp lesion complication rate and instability using arthroscopic findings. The detection rate of ramp lesions using US at the initial visit and preoperatively was also investigated. The test-retest reliability was assessed using the intraclass correlation coefficient and analyzed using two-way random effects and absolute agreement. The patients were divided into two groups based on the presence or absence of ramp lesions, and these data were compared using Student's t-test. Statistical significance was set at p < 0.05. RESULTS: On ultrasound examination, 90.0% of the cases had a ramp lesion at the initial examination, of which 22.2% were poorly delineated on the day of surgery. In the cases where the ramp lesion was unstable at the time of surgery, it could be delineated using US. In the cases where the ramp lesion was stable, it was difficult to delineate the lesion using US. CONCLUSIONS: Unstable ramp lesions complicating ACL injuries could be detected using US.


Assuntos
Meniscos Tibiais , Ultrassonografia , Adolescente , Adulto , Criança , Feminino , Humanos , Masculino , Adulto Jovem , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/patologia , Lesões do Ligamento Cruzado Anterior/cirurgia , Artroscopia , Imageamento por Ressonância Magnética/normas , Meniscos Tibiais/diagnóstico por imagem , Meniscos Tibiais/patologia , Ultrassonografia/normas
6.
Emerg Med Australas ; 36(4): 645-647, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38764348

RESUMO

OBJECTIVES: To investigate whether implementation of a hospital-based Extended Focused Assessment with Sonography in Trauma (eFAST) guideline and teaching improved documentation and saving of images. METHODS: A retrospective cohort study was conducted on trauma patients aged ≥16 years presenting to St Vincent's Hospital Sydney Emergency Department over two, three-month periods in 2023. RESULTS: Guideline and teaching implementation resulted in statistically significant improvement in documentation on the Trauma Response Form, 85% (113/133) to 93% (120/129), odds ratio (OR) 2.4 (95% confidence interval [CI] = 1.03-5.40), P = 0.04, and images saved, 4% (5/133) to 21% (27/129), OR 6.7 (95% CI = 2.5-18.2), P < 0.001. CONCLUSIONS: Developing an eFAST Standard of Care Guideline and education was associated with improvements in documentation and saving of images to ultrasound machines.


Assuntos
Documentação , Serviço Hospitalar de Emergência , Humanos , Estudos Retrospectivos , Documentação/normas , Documentação/métodos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Avaliação Sonográfica Focada no Trauma/métodos , Guias de Prática Clínica como Assunto , New South Wales , Ultrassonografia/métodos , Ultrassonografia/normas , Idoso , Adolescente
7.
J Tissue Viability ; 33(3): 481-486, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38806377

RESUMO

BACKGROUND: The main aim of this study was to ultrasonographically analyse the thickness and the relationship between the Superomedial Bundle of the Spring Ligament and the Posterior Tibial Tendon in healthy subjects and its relationship with different epidemiological variables. METHODS: Fifty-five healthy feet with a mean of 47 years old measuring the same ultrasound model and researcher. Demographic variables (age, sex, laterality, BMI, type of sports activity performed, and type of work activity) were collected from all participants. The thickness of the PTT and the Spring Ligament was measured in both longitudinal and transverse diameters. The intraclass correlation coefficient (ICC) was also analysed to assess the agreement of the measurements between a researcher and the ultrasound specialist radiologist. RESULTS: The mean thickness of the Spring ligament was 5.07 mm (95 % CI 4.75-5.38), while that of the PTT in its long axis was 3.58 mm (95 % CI 3.37-3.79). Regarding the interobserver agreement analysis, the intraclass correlation coefficient for measurements between observers was 0.91 (CI95 %: 0.698-0.977) which denotes a high degree of similarity between the clinician and the radiologist. CONCLUSION: This study describes the relationships between the thickness of the posterior tibial tendon and the superomedial Bundle of the Spring ligament in healthy subjects, as well as their variability according to certain epidemiological variables such as age, gender, occupation, and sport. On the other hand, the measurements taken by a researcher high agreement with those taken by a radiologist specialized in ultrasound.


Assuntos
Voluntários Saudáveis , Ultrassonografia , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Ultrassonografia/métodos , Ultrassonografia/estatística & dados numéricos , Ultrassonografia/normas , Adulto , Idoso , Tendões/diagnóstico por imagem , Tendões/fisiologia , Ligamentos/diagnóstico por imagem
8.
J Surg Res ; 299: 213-216, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38776576

RESUMO

INTRODUCTION: The American Urological Association guidelines recommend against the performance of ultrasound and other imaging modalities in the evaluation of patients with cryptorchidism before expert consultation. We aimed to examine our institutional experience with cryptorchidism and measure adherence to currently available guidelines. METHODS: An institutional review board-approved retrospective review of ultrasound utilization in the evaluation of patients with cryptorchidism was performed from June 1, 2016, to June 30, 2019, at a single tertiary level pediatric hospital. RESULTS: We identified 1796 patients evaluated in surgical clinics for cryptorchidism. Surgical intervention was performed in 75.2% (n = 1351) of the entire cohort. Ultrasound was performed in 42% (n = 754), most of which were ordered by referring physicians (91% n = 686). Of those who received an ultrasound, surgical intervention was performed in 78% (n = 588). Those 166 patients (22%) who did not undergo surgical intervention were referred with ultrasounds suggesting inguinal testes; however, all had normal physical examinations or mildly retractile testes at the time of consultation and were discharged from the outpatient clinic. There were 597 patients referred without an ultrasound, 81% (n = 483) were confirmed to have cryptorchidism at the time of specialist physical examination and underwent definitive surgical intervention, the remainder (19%, n = 114) were discharged from the outpatient clinics. CONCLUSIONS: Ultrasound evaluation of cryptorchidism continues despite high-quality evidence-based guidelines that recommend otherwise, as they should have little to no bearing on the surgeon's decision to operate or the type of operation. Instead, physical examination findings should guide surgical planning.


Assuntos
Criptorquidismo , Fidelidade a Diretrizes , Ultrassonografia , Humanos , Criptorquidismo/diagnóstico por imagem , Criptorquidismo/cirurgia , Masculino , Estudos Retrospectivos , Ultrassonografia/normas , Pré-Escolar , Lactente , Fidelidade a Diretrizes/estatística & dados numéricos , Criança , Guias de Prática Clínica como Assunto , Testículo/diagnóstico por imagem , Testículo/cirurgia , Encaminhamento e Consulta/normas , Encaminhamento e Consulta/estatística & dados numéricos , Adolescente
9.
Crit Care Med ; 52(8): 1251-1257, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38587423

RESUMO

OBJECTIVES: Clinical practice guidelines are essential for promoting evidence-based healthcare. While diversification of panel members can reduce disparities in care, processes for panel selection lack transparency. We aim to share our approach in forming a diverse expert panel for the updated Adult Critical Care Ultrasound Guidelines. DESIGN: This process evaluation aims to understand whether the implementation of a transparent and intentional approach to guideline panel selection would result in the creation of a diverse expert guideline panel. SETTING: This study was conducted in the setting of creating a guideline panel for the updated Adult Critical Care Ultrasound Guidelines. PATIENTS: Understanding that family/patient advocacy in guideline creations can promote the impact of a clinical practice guideline, patient representation on the expert panel was prioritized. INTERVENTIONS: Interventions included creation of a clear definition of expertise, an open invitation to the Society of Critical Care Medicine membership to apply for the panel, additional panel nomination by guideline leadership, voluntary disclosure of pre-identified diversity criteria by potential candidates, and independent review of applications including diversity criteria. This resulted in an overall score per candidate per reviewer and an open forum for discussion and final consensus. MEASUREMENTS AND MAIN RESULTS: The variables of diversity were collected and analyzed after panel selection. These were compared with historical data on panel composition. The final guideline panel comprised of 33 panelists from six countries: 45% women and 79% historically excluded people and groups. The panel has representation from nonphysician professionals and patients advocates. Of the healthcare professionals, there is representation from early, mid, and late career stages. CONCLUSIONS: Our intentional and transparent approach resulted in a panel with improved gender parity and robust diversity along ethnic, racial, and professional lines. We hope it can serve as a starting point as we strive to become a more inclusive and diverse discipline that creates globally representative guidelines.


Assuntos
Cuidados Críticos , Guias de Prática Clínica como Assunto , Ultrassonografia , Humanos , Cuidados Críticos/normas , Ultrassonografia/normas , Adulto , Feminino , Masculino
10.
Clin Physiol Funct Imaging ; 44(5): 359-370, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38616358

RESUMO

OBJECTIVE: To assess intrarater reliability of ultrasound-determined measurements of skeletal muscle characteristics across different measurement outcomes, imaging techniques, and age groups. METHODS: 2D ultrasound images (B-mode) of the quadriceps were obtained from young (26 ± 4 year, n = 8 M, 8 F) and older (70 ± 7 year, n = 7 M, 5 F) adults on two occasions, separated by 6 ± 3 days. With participants in both standing and supine postures, images were collected from five anatomical sites along the anterior (two sites) and lateral (three sites) compartments of the thigh corresponding to 56%, 39%, and 22% (lateral only) of femur length. Images were analysed for muscle thickness, pennation angle, and echogenicity. Intraclass correlation coefficients (ICC) were used to assess reliability. RESULTS: Muscle thickness values were higher (p < 0.05) on images collected in the stand versus supine posture only for muscles of the anterior compartment, independent of age. Echogenicity values were higher (p < 0.05) in the vastus intermedius on images collected in the supine versus stand posture only in older adults. Pennation angle values were not impacted by imaging posture (p > 0.05). ICC values for thickness, echogenicity, and pennation angle were generally higher for analyses conducted on images collected in the supine versus stand posture. Imaging posture generated a greater difference in ICC values in the lateral versus anterior muscles and in older versus younger participants. CONCLUSION: Our findings suggest that participant posture during imaging impacts the absolute values and intrarater reliability of ultrasound-determined muscle characteristics in a muscle-specific fashion, and this effect is greater in older compared to younger individuals.


Assuntos
Envelhecimento , Músculo Quadríceps , Músculo Quadríceps/diagnóstico por imagem , Envelhecimento/patologia , Ultrassonografia/normas , Variações Dependentes do Observador , Adulto Jovem , Adulto , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Reprodutibilidade dos Testes
11.
Curr Opin Anaesthesiol ; 37(3): 259-265, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38573182

RESUMO

PURPOSE OF REVIEW: To discuss considerations surrounding the use of point-of-care ultrasound (POCUS) in pediatric anesthesiology. RECENT FINDINGS: POCUS is an indispensable tool in various medical specialties, including pediatric anesthesiology. Credentialing for POCUS should be considered to ensure that practitioners are able to acquire images, interpret them correctly, and use ultrasound to guide procedures safely and effectively. In the absence of formal guidelines for anesthesiology, current practice and oversight varies by institution. In this review, we will explore the significance of POCUS in pediatric anesthesiology, discuss credentialing, and compare the specific requirements and challenges currently associated with using POCUS in pediatric anesthesia. SUMMARY: Point-of-care ultrasound is being utilized by the pediatric anesthesiologist and has the potential to improve patient assessment, procedure guidance, and decision-making. Guidelines increase standardization and quality assurance procedures help maintain high-quality data. Credentialing standards for POCUS in pediatric anesthesiology are essential to ensure that practitioners have the necessary skills and knowledge to use this technology effectively and safely. Currently, there are no national pediatric POCUS guidelines to base credentialing processes on for pediatric anesthesia practices. Further work directed at establishing pediatric-specific curriculum goals and competency standards are needed to train current and future pediatric anesthesia providers and increase overall acceptance of POCUS use.


Assuntos
Anestesiologia , Competência Clínica , Credenciamento , Pediatria , Sistemas Automatizados de Assistência Junto ao Leito , Ultrassonografia , Humanos , Anestesiologia/educação , Anestesiologia/normas , Credenciamento/normas , Sistemas Automatizados de Assistência Junto ao Leito/normas , Criança , Pediatria/educação , Pediatria/normas , Pediatria/métodos , Ultrassonografia/normas , Ultrassonografia/métodos , Competência Clínica/normas , Ultrassonografia de Intervenção/normas , Ultrassonografia de Intervenção/métodos
12.
Pediatr Neurol ; 155: 171-176, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38669799

RESUMO

BACKGROUND: One of the most common causes of carpal tunnel syndrome (CTS) in childhood is mucopolysaccharidosis (MPS). While ultrasonography (US) can aid in the diagnosis of CTS in adult patients, there is limited experience of this in the pediatric group. We aimed to investigate the results of wrist ultrasonography, which may be a candidate alternative to electrophysiological examination. METHODS: The participants were evaluated for symptoms, physical examination findings, electrophysiological tests and grayscale US. CTS was diagnosed in accordance with the American Academy of Orthopedic Surgeons Management of Carpal Tunnel Syndrome: Evidence-Based Clinical Practice Guideline. RESULTS: Included in the study were 27 MPS patients aged 4.5-32 years and 30 healthy control subjects aged 4.3-26 years. Of the 54 wrists in the MPS group, 30 were diagnosed with CTS. The median cross-sectional area (CSA) at the proximal carpal tunnel, the CSA at the forearm, and the wrist-forearm ratio (WFR) were higher in the wrists of the MPS with CTS group than in those without CTS and the healthy control subjects. The WFR cutoff of ≥1.35, 56.6% (95% CI: 437.4-74.5) sensitivity, and 89.8% (95% CI: 81.0-95.5) specificity were consistent with a diagnosis of CTS (receiver operating characteristics analysis, area under the curve = 0.775, 95% CI: 0.673-0.877). CONCLUSION: Although the US provides results with unsatisfactory specificity and sensitivity, it is a candidate for further investigation for the diagnosis of CTS because it is an innovative, noninvasive, and more accessible method. WFR value may produce more meaningful results than wrist or forearm nerve area measurements.


Assuntos
Síndrome do Túnel Carpal , Mucopolissacaridoses , Ultrassonografia , Humanos , Síndrome do Túnel Carpal/diagnóstico por imagem , Masculino , Ultrassonografia/normas , Mucopolissacaridoses/complicações , Mucopolissacaridoses/diagnóstico por imagem , Feminino , Criança , Adolescente , Adulto Jovem , Adulto , Pré-Escolar , Punho/diagnóstico por imagem , Sensibilidade e Especificidade , Condução Nervosa/fisiologia
13.
Arch Dis Child ; 109(7): 543-549, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38442949

RESUMO

Point-of-care ultrasound (POCUS) is an established, evidence-supported tool that can be used in neonatal and paediatric medicine, offering clinicians immediate diagnostic insights, assessment of interventions and improved safety profiles and success rate of various procedures. Its effective use requires an established education programme, governance and standardisation to ensure competence in this skill. While adult clinical practice has established POCUS training protocols, this had not been replicated in paediatrics. This article describes the development and launch of the UK's inaugural accredited paediatric-specific POCUS curriculum and training pathway: the 'Children's ACuTe UltraSound' course, addressing this significant gap in paediatric healthcare education and describing the training delivered and available for paediatricians and allied health professionals working with children.


Assuntos
Competência Clínica , Currículo , Pediatria , Sistemas Automatizados de Assistência Junto ao Leito , Ultrassonografia , Humanos , Reino Unido , Ultrassonografia/métodos , Ultrassonografia/normas , Criança , Pediatria/educação , Competência Clínica/normas
14.
Semin Arthritis Rheum ; 65: 152406, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38401294

RESUMO

OBJECTIVES: Over the last years ultrasound has shown to be an important tool for evaluating lung involvement, including interstitial lung disease (ILD) a potentially severe systemic involvement in many rheumatic and musculoskeletal diseases (RMD). Despite the potential sensitivity of the technique the actual use is hampered by the lack of consensual definitions of elementary lesions to be assessed and of the scanning protocol to apply. Within the Outcome Measures in Rheumatology (OMERACT) Ultrasound Working Group we aimed at developing consensus-based definitions for ultrasound detected ILD findings in RMDs and assessing their reliability in dynamic images. METHODS: Based on the results from a systematic literature review, several findings were identified for defining the presence of ILD by ultrasound (i.e., Am-lines, B-lines, pleural cysts and pleural line irregularity). Therefore, a Delphi survey was conducted among 23 experts in sonography to agree on which findings should be included and on their definitions. Subsequently, a web-reliability exercise was performed to test the reliability of the agreed definitions on video-clips, by using kappa statistics. RESULTS: After three rounds of Delphi an agreement >75 % was obtained to include and define B-lines and pleural line irregularity as elementary lesions to assess. The reliability in the web-based exercise, consisting of 80 video-clips (30 for pleural line irregularity, 50 for B-lines), showed moderate inter-reader reliability for both B-lines (kappa = 0.51) and pleural line irregularity (kappa = 0.58), while intra-reader reliability was good for both B-lines (kappa = 0.72) and pleural line irregularity (kappa = 0.75). CONCLUSION: Consensus-based ultrasound definitions for B-lines and pleural line irregularity were obtained, with moderate to good reliability to detect these lesions using video-clips. The next step will be testing the reliability in patients with ILD linked to RMDs and to propose a consensual and standardized protocol to scan such patients.


Assuntos
Técnica Delphi , Doenças Pulmonares Intersticiais , Ultrassonografia , Humanos , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Ultrassonografia/normas , Reprodutibilidade dos Testes , Pulmão/diagnóstico por imagem , Consenso
15.
J Neurooncol ; 167(3): 387-396, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38413458

RESUMO

PURPOSE: In an era characterized by rapid progression in neurosurgical technologies, traditional tools such as the non-navigated two-dimensional intraoperative ultrasound (nn-2D-IOUS) risk being overshadowed. Against this backdrop, this study endeavors to provide a comprehensive assessment of the clinical efficacy and surgical relevance of nn-2D-IOUS, specifically in the context of glioma resections. METHODS: This retrospective study undertaken at a single center evaluated 99 consecutive, non-selected patients diagnosed with both high-grade and low-grade gliomas. The primary objective was to assess the proficiency of nn-2D-IOUS in generating satisfactory image quality, identifying residual tumor tissue, and its influence on the extent of resection. To validate these results, early postoperative MRI data served as the reference standard. RESULTS: The nn-2D-IOUS exhibited a high level of effectiveness, successfully generating good quality images in 79% of the patients evaluated. With a sensitivity rate of 68% and a perfect specificity of 100%, nn-2D-IOUS unequivocally demonstrated its utility in intraoperative residual tumor detection. Notably, when total tumor removal was the surgical objective, a resection exceeding 95% of the initial tumor volume was achieved in 86% of patients. Additionally, patients in whom residual tumor was not detected by nn-2D-IOUS, the mean volume of undetected tumor tissue was remarkably minimal, averaging at 0.29 cm3. CONCLUSION: Our study supports nn-2D-IOUS's invaluable role in glioma surgery. The results highlight the utility of traditional technologies for enhanced surgical outcomes, even when compared to advanced alternatives. This is particularly relevant for resource-constrained settings and emphasizes optimizing existing tools for efficient patient care. NCT05873946 - 24/05/2023 - Retrospectively registered.


Assuntos
Neoplasias Encefálicas , Glioma , Padrão de Cuidado , Humanos , Glioma/cirurgia , Glioma/diagnóstico por imagem , Glioma/patologia , Estudos Retrospectivos , Neoplasias Encefálicas/cirurgia , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Idoso , Procedimentos Neurocirúrgicos/métodos , Procedimentos Neurocirúrgicos/normas , Monitorização Intraoperatória/métodos , Monitorização Intraoperatória/normas , Ultrassonografia/métodos , Ultrassonografia/normas , Adulto Jovem , Neoplasia Residual/diagnóstico por imagem , Neoplasia Residual/cirurgia , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas
16.
Anesth Analg ; 138(6): 1174-1186, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38289868

RESUMO

BACKGROUND: A noninvasive and accurate method of determining fluid responsiveness in ventilated patients would help to mitigate unnecessary fluid administration. Although carotid ultrasound has been previously studied for this purpose, several studies have recently been published. We performed an updated systematic review and meta-analysis to evaluate the accuracy of carotid ultrasound as a tool to predict fluid responsiveness in ventilated patients. METHODS: Studies eligible for review investigated the accuracy of carotid ultrasound parameters in predicting fluid responsiveness in ventilated patients, using sensitivity and specificity as markers of diagnostic accuracy (International Prospective Register of Systematic Reviews [PROSPERO] CRD42022380284). All included studies had to use an independent method of determining cardiac output and exclude spontaneously ventilated patients. Six bibliographic databases and 2 trial registries were searched. Medline, Embase, Emcare, APA PsycInfo, CINAHL, and the Cochrane Library were searched on November 4, 2022. Clinicaltrials.gov and Australian New Zealand Clinical Trials Registry were searched on February 24, 2023. Results were pooled, meta-analysis was conducted where possible, and hierarchical summary receiver operating characteristic models were used to compare carotid ultrasound parameters. Bias and evidence quality were assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool and the Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) guidelines. RESULTS: Thirteen prospective clinical studies were included (n = 648 patients), representing 677 deliveries of volume expansion, with 378 episodes of fluid responsiveness (58.3%). A meta-analysis of change in carotid Doppler peak velocity (∆CDPV) yielded a sensitivity of 0.79 (95% confidence interval [CI], 0.74-0.84) and a specificity of 0.85 (95% CI, 0.76-0.90). Risk of bias relating to recruitment methodology, the independence of index testing to reference standards and exclusionary clinical criteria were evaluated. Overall quality of evidence was low. Study design heterogeneity, including a lack of clear parameter cutoffs, limited the generalizability of our results. CONCLUSIONS: In this meta-analysis, we found that existing literature supports the ability of carotid ultrasound to predict fluid responsiveness in mechanically ventilated adults. ∆CDPV may be an accurate carotid parameter in certain contexts. Further high-quality studies with more homogenous designs are needed to further validate this technology.


Assuntos
Artérias Carótidas , Hidratação , Valor Preditivo dos Testes , Respiração Artificial , Humanos , Artérias Carótidas/diagnóstico por imagem , Ultrassonografia/métodos , Ultrassonografia/normas , Reprodutibilidade dos Testes , Ultrassonografia das Artérias Carótidas
18.
Zhonghua Yi Xue Za Zhi ; 103(31): 2365-2388, 2023 Aug 22.
Artigo em Chinês | MEDLINE | ID: mdl-37599213

RESUMO

Liver transplantation is currently the only effective treatment for end-stage liver disease. Ultrasound examination has the advantages of non-invasive, convenient, and real-time display the intrahepatic vascular hemodynamic changes, and has become one of the preferred evaluation methods in the entire management process of liver transplantation. To further standardize the ultrasound examinations before and after liver transplantation, multiple-disciplinary experts in the field of liver transplantation, including specialists in ultrasound, liver surgery, and intervention medicine, were organized by the Chinese Medical Association Ultrasound Medicine Branch, the Chinese Medical Doctor Association Surgery Physician Branch, the Chinese Medical Doctor Association Interventional Physician Branch, and the Shanghai Medical Association Ultrasound Medicine Branch. Combined with the latest research practice in ultrasound diagnosis and treatment of liver transplantation, the ultrasound clinical practice guidelines for liver transplantation (2023 edition) was formulated. The contents of this guideline include ultrasound evaluation of liver transplantation donors and recipients, intraoperative and postoperative ultrasound examination of transplant livers, ultrasound applications in pediatric liver transplantation, and ultrasound-guided liver puncture biopsy and treatment, aiming to promote the standardized and high-quality development of liver transplantation ultrasound examination in China.


Assuntos
Transplante de Fígado , Fígado , Ultrassonografia , Humanos , Povo Asiático , China , Fígado/diagnóstico por imagem , Fígado/patologia , Fígado/cirurgia , Ultrassonografia/métodos , Ultrassonografia/normas , Doença Hepática Terminal/diagnóstico por imagem , Doença Hepática Terminal/cirurgia
19.
PeerJ ; 11: e15418, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37304881

RESUMO

Background: The use of sonography is a cost-effective and reliable method to evaluate upper extremity superficial tissue structural integrity and pathology. Establishing the measurement reliability of widely used diagnostic ultrasound evaluation for musculoskeletal assessment is paramount enhance accurate clinical evaluations. The objective of this study was to establish the inter-rater and intra-rater reliability of select ulnar collateral ligament (UCL) thickness measures at two distinct anatomical locations in intercollegiate baseball athletes using ultrasound imaging (USI). Methods: This was a prospective cohort study conducted in a university research laboratory and included a total of 17 NCAA Division I baseball athletes (age 20.4 ± 1.43, height = 183.63 cm ± 6.27 cm, mass = 89.28 kg ± 8.24 kg). Two trained clinicians measured UCL mid-substance and apex thickness in the throwing extremity, prospectively, on 5 occasions at 1-month intervals during rest. Intraclass correlation coefficients (ICCs) (model 3,3), associated standard error of measurement, and 95% minimal detectable change in thickness were derived. Results: Intrarater reliability estimates for operator 1 were 0.90-0.98 (mid-substance) and 0.91-0.99 (apex). Operator 2's values were 0.92-0.97 and 0.93-0.99, respectively. The standard error of measurement (SEM) ranged from 0.045-0.071 cm (mid-substance) and 0.023-0.067 cm (apex). The minimal detectable difference (MDD95) was 0.12-0.20 cm (mid-substance) and 0.07-0.19 cm (apex). Interrater reliability was 0.86-0.96 (mid-substance) and 0.79-0.98 (apex); most ICCs were >0.90. Measurement of UCL thickness at two locations demonstrated very good to excellent reliability with high precision. Using this protocol, two evaluators can obtain consistent UCL measurement at two positions. This finding has significant implications for the clinical evaluation of superficial tissue pathology of the same individual by two experienced practitioners.


Assuntos
Ligamento Colateral Ulnar , Ultrassonografia , Humanos , Adolescente , Adulto Jovem , Adulto , Ligamento Colateral Ulnar/diagnóstico por imagem , Ultrassonografia/normas , Reprodutibilidade dos Testes , Estudos Prospectivos , Estudos de Coortes
20.
J Clin Ultrasound ; 51(5): 876-878, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37025024

RESUMO

High-pressure injection injuries of the hand are uncommon accidents with potentially catastrophic complications. We present a case of a 49-years-old male with a high-pressure injection of motor oil in his left hand. Ultrasound accurately demonstrated soft tissue infiltration and late complications, playing a fundamental role in the treatment choice.


Assuntos
Traumatismos da Mão , Óleos Industriais , Ultrassonografia , Humanos , Masculino , Pessoa de Meia-Idade , Traumatismos da Mão/diagnóstico por imagem , Traumatismos da Mão/terapia , Pressão , Injeções , Ultrassonografia/normas , Imageamento por Ressonância Magnética , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA