Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 12.299
Filtrar
1.
Open Heart ; 11(1)2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38719499

RESUMO

OBJECTIVE: Implantable loop recorders (ILRs) are increasingly used for long-term rhythm monitoring after ischaemic and cryptogenic stroke, with the goal of detecting atrial fibrillation (AF) and subsequent initiation of oral anticoagulation to reduce risk of adverse clinical outcomes. There is a need to determine the effectiveness of different rhythm monitoring strategies in this context. METHODS: We conducted a retrospective cohort analysis of individuals with commercial and Medicare Advantage insurance in Optum Labs Data Warehouse who had incident ischaemic or cryptogenic stroke and no prior cardiovascular implantable electronic device from 1 January 2016 to 30 June 2021. Patients were stratified by rhythm monitoring strategy: ILR, long-term continuous external cardiac monitor (>48 hours to 30 days) or Holter monitor (≤48 hours). The primary outcome was risk-adjusted all-cause mortality at 12 months. Secondary outcomes included new diagnosis of AF and oral anticoagulation, bleeding, and costs. RESULTS: Among 48 901 patients with ischaemic or cryptogenic stroke, 9235 received an ILR, 29 103 long-term continuous external monitor and 10 563 Holter monitor only. Mean age was 69.9 (SD 11.9) years and 53.5% were female. During the 12-month follow-up period, patients who received ILRs compared with those who received long-term continuous external monitors had a higher odds of new diagnosis of AF and oral anticoagulant initiation (adjusted OR 2.27, 95% CI 2.09 to 2.48). Compared with patients who received long-term continuous external monitors, those who received ILRs had similar 12-month mortality (HR 1.00; 95% CI 0.89 to 1.12), with approximately $13 000 higher costs at baseline (including monitor cost) and $2500 higher costs during 12-month follow-up. CONCLUSIONS: In this large real-world study of patients with ischaemic or cryptogenic stroke, ILR placement resulted in more diagnosis of AF and initiation of oral anticoagulation, but no difference in mortality compared with long-term continuous external monitors.


Assuntos
Fibrilação Atrial , Eletrocardiografia Ambulatorial , AVC Isquêmico , Humanos , Feminino , Masculino , Idoso , Estudos Retrospectivos , Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia Ambulatorial/economia , Eletrocardiografia Ambulatorial/métodos , AVC Isquêmico/economia , AVC Isquêmico/mortalidade , AVC Isquêmico/diagnóstico , AVC Isquêmico/prevenção & controle , AVC Isquêmico/etiologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/economia , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/complicações , Fibrilação Atrial/mortalidade , Estados Unidos/epidemiologia , Anticoagulantes/economia , Anticoagulantes/administração & dosagem , Fatores de Tempo , Pessoa de Meia-Idade , Seguimentos , Análise Custo-Benefício , Idoso de 80 Anos ou mais , Custos de Cuidados de Saúde
2.
Open Heart ; 11(1)2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38719497

RESUMO

BACKGROUND: The treatment of pulmonary hypertension (PH) has improved rapidly in recent decades. There is increasing evidence to support the role of early intervention and treatment in affecting clinical outcomes in PH. OBJECTIVES: To assess treatment effects before and after the escalation of specific PH treatments using continuous heart monitoring with a Reveal LINQ loop recorder. METHODS: Patients were compared before and after treatment escalation. Treatment escalation was defined as an additional pulmonary arterial hypertension (PAH) drug, pulmonary endarterectomy, percutaneous balloon angioplasty or bilateral lung transplantation. Specifically, changes in heart rate variability (HRV), heart rate (HR) and physical activity were assessed. RESULTS: In this prospective study, 41 patients (27 with PAH and 14 with chronic thromboembolic pulmonary hypertension (CTEPH)) were enrolled. Among them, 15 (36.6%) patients underwent PH treatment escalation. Prior to escalation, patients were monitored for a median of 100 (range: 68-100) days and after therapy escalation for a median duration of 165 (range: 89-308) days. In the escalation group, there was a significant increase in HRV, physical activity indexed by daytime HR and a significant decrease in nighttime HR assessed at baseline and after treatment escalation in both the PAH and CTEPH groups. This was paralleled by significant improvements in WHO functional class, 6-min walking distance and N-terminal pro-b-type natriuretic peptide. CONCLUSIONS: This is the first study to demonstrate an association between specific PH therapies and changes in HRV, HR nighttime and physical activity. This indicates the potential of continuous monitoring in the evaluation of treatment effects in PH.


Assuntos
Frequência Cardíaca , Hipertensão Pulmonar , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Frequência Cardíaca/fisiologia , Hipertensão Pulmonar/fisiopatologia , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/terapia , Resultado do Tratamento , Endarterectomia/métodos , Idoso , Anti-Hipertensivos/uso terapêutico , Fatores de Tempo , Angioplastia com Balão/métodos , Adulto , Transplante de Pulmão , Eletrocardiografia Ambulatorial/métodos , Artéria Pulmonar/fisiopatologia
3.
BMC Cardiovasc Disord ; 24(1): 257, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38760695

RESUMO

BACKGROUND: This study aimed to investigate the potential association between the circadian rhythm of blood pressure and deceleration capacity (DC)/acceleration capacity (AC) in patients with essential hypertension. METHODS: This study included 318 patients with essential hypertension, whether or not they were being treated with anti-hypertensive drugs, who underwent 24-hour ambulatory blood pressure monitoring (ABPM). Patients were categorized into three groups based on the percentage of nocturnal systolic blood pressure (SBP) dipping: the dipper, non-dipper and reverse dipper groups. Baseline demographic characteristics, ambulatory blood pressure monitoring parameters, Holter recordings (including DC and AC), and echocardiographic parameters were collected. RESULTS: In this study, the lowest DC values were observed in the reverse dipper group, followed by the non-dipper and dipper groups (6.46 ± 2.06 vs. 6.65 ± 1.95 vs. 8.07 ± 1.79 ms, P < .001). Additionally, the AC gradually decreased (-6.32 ± 2.02 vs. -6.55 ± 1.95 vs. -7.80 ± 1.73 ms, P < .001). There was a significant association between DC (r = .307, P < .001), AC (r=-.303, P < .001) and nocturnal SBP decline. Furthermore, DC (ß = 0.785, P = .001) was positively associated with nocturnal SBP decline, whereas AC was negatively associated with nocturnal SBP (ß = -0.753, P = .002). By multivariate logistic regression analysis, deceleration capacity [OR (95% CI): 0.705 (0.594-0.836), p < .001], and acceleration capacity [OR (95% CI): 1.357 (1.141-1.614), p = .001] were identified as independent risk factors for blood pressure nondipper status. The analysis of ROC curves revealed that the area under the curve for DC/AC in predicting the circadian rhythm of blood pressure was 0.711/0.697, with a sensitivity of 73.4%/65.1% and specificity of 66.7%/71.2%. CONCLUSIONS: Abnormal DC and AC density were correlated with a blunted decline in nighttime SBP, suggesting a potential association between the circadian rhythm of blood pressure in essential hypertension patients and autonomic nervous dysfunction.


Assuntos
Anti-Hipertensivos , Monitorização Ambulatorial da Pressão Arterial , Pressão Sanguínea , Ritmo Circadiano , Hipertensão Essencial , Frequência Cardíaca , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Hipertensão Essencial/fisiopatologia , Hipertensão Essencial/diagnóstico , Hipertensão Essencial/tratamento farmacológico , Fatores de Tempo , Anti-Hipertensivos/uso terapêutico , Idoso , Valor Preditivo dos Testes , Adulto , Fatores de Risco , Eletrocardiografia Ambulatorial , Aceleração , Desaceleração
4.
Scand Cardiovasc J ; 58(1): 2353069, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38794854

RESUMO

OBJECTIVES: Atrial fibrillation (AF) is a common early arrhythmia after heart valve surgery that limits physical activity. We aimed to evaluate the criterion validity of the Apple Watch Series 5 single-lead electrocardiogram (ECG) for detecting AF in patients after heart valve surgery. DESIGN: We enrolled 105 patients from the University Hospital of North Norway, of whom 93 completed the study. All patients underwent single-lead ECG using the smartwatch three times or more daily on the second to third or third to fourth postoperative day. These results were compared with continuous 2-4 days ECG telemetry monitoring and a 12-lead ECG on the third postoperative day. RESULTS: On comparing the Apple Watch ECGs with the ECG monitoring, the sensitivity and specificity to detect AF were 91% (75, 100) and 96% (91, 99), respectively. The accuracy was 95% (91, 99). On comparing Apple Watch ECG with a 12-lead ECG, the sensitivity was 71% (62, 100) and the specificity was 92% (92, 100). CONCLUSION: The Apple smartwatch single-lead ECG has high sensitivity and specificity, and might be a useful tool for detecting AF in patients after heart valve surgery.


Assuntos
Fibrilação Atrial , Frequência Cardíaca , Valor Preditivo dos Testes , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Masculino , Estudos Prospectivos , Feminino , Idoso , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Noruega , Fatores de Tempo , Aplicativos Móveis , Resultado do Tratamento , Eletrocardiografia Ambulatorial/instrumentação , Telemetria/instrumentação , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Dispositivos Eletrônicos Vestíveis , Eletrocardiografia , Valvas Cardíacas/cirurgia , Valvas Cardíacas/fisiopatologia
5.
EuroIntervention ; 20(9): 591-601, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38726722

RESUMO

BACKGROUND: Little is known about the occurrence of subclinical new-onset atrial fibrillation (NOAF) after transcatheter aortic valve implantation (TAVI). AIMS: We aimed to evaluate the incidence, predictors, and clinical impact of subclinical NOAF after TAVI. METHODS: This was a multicentre study, including patients with aortic stenosis (AS) and no previous atrial fibrillation undergoing TAVI, with continuous ambulatory electrocardiogram (AECG) monitoring after TAVI. RESULTS: A total of 700 patients (79±8 years, 49% female, Society of Thoracic Surgeons score 2.9% [1.9-4.0]) undergoing transarterial TAVI were included (85% balloon-expandable valves). AECG was started 1 (0-1) day after TAVI (monitoring time: 14121314 days). NOAF was detected in 49 patients (7%), with a median duration of 185 (43-421) minutes (atrial fibrillation burden of 0.7% [0.3-2.8]). Anticoagulation was started in 25 NOAF patients (51%). No differences were found in baseline or procedural characteristics, except for a higher AS severity in the NOAF group (peak gradient: no NOAF: 71.9±23.5 mmHg vs NOAF: 85.2±23.8 mmHg; p=0.024; mean gradient: no NOAF: 44.4±14.7 mmHg vs NOAF: 53.8±16.8 mmHg; p=0.004). In the multivariable analysis, the baseline mean transaortic gradient was associated with a higher risk of NOAF after TAVI (odds ratio 1.04, 95% confidence interval: 1.01-1.06 for each mmHg; p=0.006). There were no differences between groups in all-cause mortality (no NOAF: 4.7% vs NOAF: 0%; p=0.122), stroke (no NOAF: 1.4% vs NOAF: 2.0%; p=0.723), or bleeding (no NOAF: 1.9% vs NOAF: 4.1%; p=0.288) from the 30-day to 1-year follow-up. CONCLUSIONS: NOAF detected with AECG occurred in 7% of TAVI recipients and was associated with a higher AS severity. NOAF detection determined the start of anticoagulation therapy in about half of the patients, and it was not associated with an increased risk of clinical events at 1-year follow-up.


Assuntos
Estenose da Valva Aórtica , Fibrilação Atrial , Eletrocardiografia Ambulatorial , Substituição da Valva Aórtica Transcateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Estenose da Valva Aórtica/cirurgia , Idoso de 80 Anos ou mais , Eletrocardiografia Ambulatorial/métodos , Fatores de Risco , Resultado do Tratamento
6.
Arch Cardiovasc Dis ; 117(5): 313-320, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38704288

RESUMO

BACKGROUND: In patients with congenital long QT syndrome (LQTS), the risk of ventricular arrhythmia is correlated with the duration of the corrected QT interval and the changes in the ST-T wave pattern on the 12-lead surface electrocardiogram (12L-ECG). Remote monitoring of these variables could be useful. AIM: To evaluate the abilities of two wearable electrocardiogram devices (Apple Watch and KardiaMobile 6L) to provide reliable electrocardiograms in terms of corrected QT interval and ST-T wave patterns in patients with LQTS. METHODS: In a prospective multicentre study (ClinicalTrials.gov identifier: NCT04728100), a 12L-ECG, a 6-lead KardiaMobile 6L electrocardiogram and two single-lead Apple Watch electrocardiograms were recorded in patients with LQTS. The corrected QT interval and ST-T wave patterns were evaluated manually. RESULTS: Overall, 98 patients with LQTS were included; 12.2% were children and 92.8% had a pathogenic variant in an LQTS gene. The main genotypes were LQTS type 1 (40.8%), LQTS type 2 (36.7%) and LQTS type 3 (7.1%); rarer genotypes were also represented. When comparing the ST-T wave patterns obtained with the 12L-ECG, the level of agreement was moderate with the Apple Watch (k=0.593) and substantial with the KardiaMobile 6L (k=0.651). Regarding the corrected QT interval, the correlation with 12L-ECG was strong for the Apple Watch (r=0.703 in lead II) and moderate for the KardiaMobile 6L (r=0.593). There was a slight overestimation of corrected QT interval with the Apple Watch and a subtle underestimation with the KardiaMobile 6L. CONCLUSIONS: In patients with LQTS, the corrected QT interval and ST-T wave patterns obtained with the Apple Watch and the KardiaMobile 6L correlated with the 12L-ECG. Although wearable electrocardiogram devices cannot replace the 12L-ECG for the follow-up of these patients, they could be interesting additional monitoring tools.


Assuntos
Frequência Cardíaca , Síndrome do QT Longo , Valor Preditivo dos Testes , Dispositivos Eletrônicos Vestíveis , Humanos , Síndrome do QT Longo/fisiopatologia , Síndrome do QT Longo/diagnóstico , Síndrome do QT Longo/congênito , Síndrome do QT Longo/genética , Feminino , Masculino , Estudos Prospectivos , Criança , Adolescente , Adulto , Reprodutibilidade dos Testes , Adulto Jovem , Eletrocardiografia Ambulatorial/instrumentação , Potenciais de Ação , Pré-Escolar , Desenho de Equipamento , Fatores de Tempo , Pessoa de Meia-Idade , Eletrocardiografia/instrumentação , Sistema de Condução Cardíaco/fisiopatologia
7.
J Med Syst ; 48(1): 57, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38801649

RESUMO

Wearable electronics are increasingly common and useful as health monitoring devices, many of which feature the ability to record a single-lead electrocardiogram (ECG). However, recording the ECG commonly requires the user to touch the device to complete the lead circuit, which prevents continuous data acquisition. An alternative approach to enable continuous monitoring without user initiation is to embed the leads in a garment. This study assessed ECG data obtained from the YouCare device (a novel sensorized garment) via comparison with a conventional Holter monitor. A cohort of thirty patients (age range: 20-82 years; 16 females and 14 males) were enrolled and monitored for twenty-four hours with both the YouCare device and a Holter monitor. ECG data from both devices were qualitatively assessed by a panel of three expert cardiologists and quantitatively analyzed using specialized software. Patients also responded to a survey about the comfort of the YouCare device as compared to the Holter monitor. The YouCare device was assessed to have 70% of its ECG signals as "Good", 12% as "Acceptable", and 18% as "Not Readable". The R-wave, independently recorded by the YouCare device and Holter monitor, were synchronized within measurement error during 99.4% of cardiac cycles. In addition, patients found the YouCare device more comfortable than the Holter monitor (comfortable 22 vs. 5 and uncomfortable 1 vs. 18, respectively). Therefore, the quality of ECG data collected from the garment-based device was comparable to a Holter monitor when the signal was sufficiently acquired, and the garment was also comfortable.


Assuntos
Eletrocardiografia Ambulatorial , Eletrocardiografia , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Adulto , Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia Ambulatorial/métodos , Idoso de 80 Anos ou mais , Eletrocardiografia/instrumentação , Eletrocardiografia/métodos , Dispositivos Eletrônicos Vestíveis , Adulto Jovem , Vestuário , Processamento de Sinais Assistido por Computador/instrumentação
8.
J Am Heart Assoc ; 13(11): e032465, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38804218

RESUMO

BACKGROUND: New methods to identify patients who benefit from a primary prophylactic implantable cardioverter-defibrillator (ICD) are needed. T-wave alternans (TWA) has been shown to associate with arrhythmogenesis of the heart and sudden cardiac death. We hypothesized that TWA might be associated with benefit from ICD implantation in primary prevention. METHODS AND RESULTS: In the EU-CERT-ICD (European Comparative Effectiveness Research to Assess the Use of Primary Prophylactic Implantable Cardioverter-Defibrillators) study, we prospectively enrolled 2327 candidates for primary prophylactic ICD. A 24-hour Holter monitor reading was taken from all recruited patients at enrollment. TWA was assessed from Holter monitoring using the modified moving average method. Study outcomes were all-cause death, appropriate shock, and survival benefit. TWA was assessed both as a contiguous variable and as a dichotomized variable with cutoff points <47 µV and <60 µV. The final cohort included 1734 valid T-wave alternans samples, 1211 patients with ICD, and 523 control patients with conservative treatment, with a mean follow-up time of 2.3 years. TWA ≥60 µV was a predicter for a higher all-cause death in patients with an ICD on the basis of a univariate Cox regression model (hazard ratio, 1.484 [95% CI, 1.024-2.151]; P=0.0374; concordance statistic, 0.51). In multivariable models, TWA was not prognostic of death or appropriate shocks in patients with an ICD. In addition, TWA was not prognostic of death in control patients. In a propensity score-adjusted Cox regression model, TWA was not a predictor of ICD benefit. CONCLUSIONS: T-wave alternans is poorly prognostic in patients with a primary prophylactic ICD. Although it may be prognostic of life-threatening arrhythmias and sudden cardiac death in several patient populations, it does not seem to be useful in assessing benefit from ICD therapy in primary prevention among patients with an ejection fraction of ≤35%.


Assuntos
Morte Súbita Cardíaca , Desfibriladores Implantáveis , Eletrocardiografia Ambulatorial , Prevenção Primária , Humanos , Prevenção Primária/métodos , Masculino , Feminino , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Eletrocardiografia Ambulatorial/métodos , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Medição de Risco/métodos , Fatores de Risco , Arritmias Cardíacas/terapia , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/prevenção & controle , Arritmias Cardíacas/mortalidade , Resultado do Tratamento , Valor Preditivo dos Testes , Fatores de Tempo , Europa (Continente)/epidemiologia , Prognóstico , Frequência Cardíaca/fisiologia
9.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38584469

RESUMO

AIMS: Brugada syndrome (BrS) diagnosis and risk stratification rely on the presence of a spontaneous type 1 (spT1) electrocardiogram (ECG) pattern; however, its spontaneous fluctuations may lead to misdiagnosis and risk underestimation. This study aims to assess the role for repeat high precordial lead (HPL) resting and ambulatory ECG monitoring in identifying a spT1, and evaluate its prognostic role. METHODS AND RESULTS: HPL resting and ambulatory monitoring ECGs of BrS subjects were reviewed retrospectively, and the presence of a spT1 associated with ventricular dysrhythmias and sudden cardiac death (SCD). Three-hundred and fifty-eight subjects (77 with spT1 pattern at presentation, Group 1, and 281 without, Group 2) were included. In total, 1651 resting HPL resting and 621 ambulatory monitoring ECGs were available for review, or adequately described. Over a median follow-up of 72 months (interquartile range - IQR - 75), 42/77 (55%) subjects in Group 1 showed a spT1 in at least one ECG. In Group 2, 36/281 subjects (13%) had a newly detected spT1 (1.9 per 100 person-year) and 23 on an HPL ambulatory recording (8%). Seven previously asymptomatic subjects, five of whom had a spT1 (four at presentation and one at follow-up), experienced arrhythmic events; survival analysis indicated that a spT1, either at presentation or during lifetime, was associated with events. Univariate models showed that a spT1 was consistently associated with increased risk [spT1 at presentation: hazard ratio (HR) 6.3, 95% confidence interval (CI) 1.4-28, P = 0.016; spT1 at follow-up: HR 3.1, 95% CI 1.3-7.2, P = 0.008]. CONCLUSION: Repeated ECG evaluation and HPL ambulatory monitoring are vital in identifying transient spT1 Brugada pattern and its associated risk.


Assuntos
Síndrome de Brugada , Morte Súbita Cardíaca , Eletrocardiografia Ambulatorial , Humanos , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/fisiopatologia , Masculino , Feminino , Eletrocardiografia Ambulatorial/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos , Prognóstico , Adulto , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Medição de Risco , Valor Preditivo dos Testes , Fatores de Risco , Frequência Cardíaca , Idoso
10.
Clin Cardiol ; 47(4): e24266, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38587231

RESUMO

BACKGROUND: Electrocardiography (ECG) and 24 hours Holter monitoring (24 h-Holter) provided valuable information for premature ventricular and supraventricular contractions (PVC and PSVC). Currently, artificial intelligence (AI) based 2 hours single-lead Holter (2 h-Holter) monitoring may provide an improved strategy for PSVC/PVC diagnosis. HYPOTHESIS: AI combined with single-lead Holter monitoring improves PSVC/PVC detection. METHODS: In total, 170 patients were enrolled between August 2022 and 2023. All patients wore both devices simultaneously; then, we compared diagnostic efficiency, including the sensitivity/specificity/positive predictive-value (PPV) and negative predictive-value (NPV) in detecting PSVC/PVC by 24 h-Holter and 2 h-Holter. RESULTS: The PPV and NPV in patients underwent 2 h-Holter were 76.00%/87.50% and 96.35%/98.55, respectively, and the sensitivity and specificity were 79.17%/91.30%, and 95.65%/97.84% in PSVC/PVC detection compared with 24 h-Holter. The areas under the ROC curves (AUCs) for PSVC and PVC were 0.885 and 0.741, respectively (p < .0001). CONCLUSIONS: The potential advantages of the 2 h-Holter were shortened wearing period, improved convenience, and excellent consistency of diagnosis.


Assuntos
Eletrocardiografia Ambulatorial , Complexos Ventriculares Prematuros , Humanos , Inteligência Artificial , Complexos Ventriculares Prematuros/diagnóstico , Eletrocardiografia , Valor Preditivo dos Testes
11.
Sci Rep ; 14(1): 8969, 2024 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637619

RESUMO

Duchenne muscular dystrophy (DMD) patients exhibit a late left ventricular systolic dysfunction preceded by an occult phase, during which myocardial fibrosis progresses and some early functional impairments can be detected. These latter include electrocardiographic (ECG) and heart rate variability (HRV) abnormalities. This longitudinal study aimed at describing the sequence of ECG and HRV abnormalities, using Holter ECG in the GRMD (Golden retriever muscular dystrophy) dog model, known to develop a DMD-like disease, including cardiomyopathy. Most of the known ECG abnormalities described in DMD patients were also found in GRMD dogs, including increased heart rate, prolonged QT and shortened PR intervals, ventricular arrhythmias, and several of them could be detected months before the decrease of fractional shortening. The HRV was impaired like in DMD patients, one of the earliest evidenced abnormalities being a decrease in the very low frequency (VLF) component of the power spectrum. This decrease was correlated with the further reduction of fractional shortening. Such decreased VLF probably reflects impaired autonomic function and abnormal vasomotor tone. This study provides new insights into the knowledge of the GRMD dog model and DMD cardiomyopathy and emphasizes the interest to monitor the VLF power in DMD patients, still unexplored in this disease, whilst it is highly predictive of deleterious clinical events in many other pathological conditions.


Assuntos
Cardiomiopatias , Distrofia Muscular de Duchenne , Humanos , Cães , Animais , Distrofia Muscular de Duchenne/patologia , Frequência Cardíaca , Eletrocardiografia Ambulatorial , Estudos Longitudinais
12.
BMC Neurol ; 24(1): 120, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38605308

RESUMO

BACKGROUND: Atrial fibrillation (AF) screening after ischemic stroke or transient ischemic attack (TIA) is given high priority in clinical guidelines. However, patient selection, electrocardiogram (ECG) modality and screening duration remains undecided and current recommendations vary. METHODS: The aim of this study was to investigate the clinical practice of AF screening after ischemic stroke or TIA at Swedish stroke units. In collaboration with the stakeholders of the Swedish Stroke Register (Riksstroke) a digital survey was drafted, then tested and revised by three stroke consultants. The survey consisted of 17 multiple choice/ free text questions and was sent by e-mail to the medical directors at all stroke units in Sweden. RESULTS: All 72 stroke units in Sweden responded to the survey. Most stroke units reported that ≥ 75% of ischemic stroke (69/72 stroke units) or TIA patients (67/72 stroke units), without previously known AF, were screened for AF. Inpatient telemetry ECG was the method of first-choice in 81% of the units, but 7% reported lack of access. A variety of standard monitoring durations were used for inpatient telemetry ECG. The second most common choice was Holter ECG (17%), also with considerable variations in monitoring duration. Other AF screening modalities were used as a first-choice method (handheld and patch ECG) but less frequently. CONCLUSIONS: Clinical practice for AF screening after ischemic stroke or TIA differed between Swedish stroke units, both in choice of AF screening methods as well as in monitoring durations. There is an urgent need for evidence and evidence-based recommendations in this field. TRIAL REGISTRATION: Not applicable.


Assuntos
Fibrilação Atrial , Ataque Isquêmico Transitório , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Ataque Isquêmico Transitório/complicações , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/epidemiologia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Suécia/epidemiologia , Eletrocardiografia Ambulatorial , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia
14.
Comput Methods Programs Biomed ; 249: 108157, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38582037

RESUMO

BACKGROUND AND OBJECTIVE: T-wave alternans (TWA) is a fluctuation in the repolarization morphology of the ECG. It is associated with cardiac instability and sudden cardiac death risk. Diverse methods have been proposed for TWA analysis. However, TWA detection in ambulatory settings remains a challenge due to the absence of standardized evaluation metrics and detection thresholds. METHODS: In this work we use traditional TWA analysis signal processing-based methods for feature extraction, and two machine learning (ML) methods, namely, K-nearest-neighbor (KNN) and random forest (RF), for TWA detection, addressing hyper-parameter tuning and feature selection. The final goal is the detection in ambulatory recordings of short, non-sustained and sparse TWA events. RESULTS: We train ML methods to detect a wide variety of alternant voltage from 20 to 100 µV, i.e., ranging from non-visible micro-alternans to TWA of higher amplitudes, to recognize a wide range in concordance to risk stratification. In classification, RF outperforms significantly the recall in comparison with the signal processing methods, at the expense of a small lost in precision. Despite ambulatory detection stands for an imbalanced category context, the trained ML systems always outperform signal processing methods. CONCLUSIONS: We propose a comprehensive integration of multiple variables inspired by TWA signal processing methods to fed learning-based methods. ML models consistently outperform the best signal processing methods, yielding superior recall scores.


Assuntos
Arritmias Cardíacas , Eletrocardiografia Ambulatorial , Humanos , Eletrocardiografia Ambulatorial/métodos , Frequência Cardíaca , Arritmias Cardíacas/diagnóstico , Morte Súbita Cardíaca , Processamento de Sinais Assistido por Computador , Eletrocardiografia/métodos
15.
Medicina (Kaunas) ; 60(4)2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38674301

RESUMO

Coronavirus disease 2019 (COVID-19) has affected medical practice. More than 7,000,000 patients died worldwide after being infected with COVID-19; however, no specific laboratory markers have yet been established to predict death related to this disease. In contrast, electrocardiographic changes due to COVID-19 include QT prolongation and ST-T changes; however, there have not been studies on the ambulatory electrocardiographic markers of COVID-19. We encountered three patients diagnosed as having COVID-19 who did not have a prior history of significant structural heart diseases. All patients had abnormalities in ambulatory echocardiogram parameters detected by high-resolution 24 h electrocardiogram monitoring: positive late potentials (LPs) and T-wave alternans (TWA), abnormal heart rate variability (HRV), and heart rate turbulence (HRT). Case 1 involved a 78-year-old woman with a history of chronic kidney disease, Case 2 involved a 76-year-old man with hypertension and diabetes, and Case 3 involved a 67-year-old man with renal cancer, lung cancer, and diabetes. None of them had a prior history of significant structural heart disease. Although no significant consistent increases in clinical markers were observed, all three patients died, mainly because of respiratory failure with mild heart failure. The LP, TWA, HRV, and HRT were positive in all three cases with no significant structural cardiac disease at the initial phase of admission. The further accumulation of data regarding ambulatory electrocardiographic markers in patients with COVID-19 is needed. Depending on the accumulation of data, the LP, TWA, HRV, and HRT could be identified as potential risk factors for COVID-19 pneumonia in the early phase of admission.


Assuntos
COVID-19 , Eletrocardiografia Ambulatorial , SARS-CoV-2 , Humanos , COVID-19/complicações , COVID-19/fisiopatologia , COVID-19/diagnóstico , Idoso , Feminino , Masculino
16.
Korean J Intern Med ; 39(3): 469-476, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38632895

RESUMO

BACKGROUND/AIMS: The reimbursement policy for cryptogenic stroke (CS) was expanded in November 2018 from recurrent strokes to the first stroke episode. No reports have demonstrated whether this policy change has affected trends in implantable loop recorder (ILR) utilization. METHODS: We identified patients who received an ILR implant using the Korea Health Insurance Review and Assessment Service database between July 2016 and October 2021. Patients meeting all the following criteria were considered to have CS indication: 1) prior stroke history, 2) no previous history of atrial fibrillation or flutter (AF/AFL), and 3) no maintenance of oral anticoagulant for ≥4 weeks within a year before ILR implant. AF/AFL diagnosed within 3 years after ILR implant or before ILR removal was considered ILR-driven. RESULTS: Among 3,056 patients, 1,001 (32.8%) had CS indications. The total ILR implant number gradually increased for both CS and non-CS indications and the number of CS indication significantly increased after implementing the expanded reimbursement policy. The detection rate for AF/AFL was 26.3% in CS patients over 3 years, which was significantly higher in patients implanted with an ILR within 2 months after stroke than those implanted later. CONCLUSION: The expanded coverage policy for CS had a significant impact on the number of ILR implantation for CS indication. The diagnostic yield of ILR for AF/AFL detection seems better when ILR is implanted within 2 months than later. Further investigation is needed to demonstrate other clinical benefits and the optimal ILR implantation timing.


Assuntos
AVC Isquêmico , Humanos , República da Coreia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , AVC Isquêmico/diagnóstico , Bases de Dados Factuais , Fatores de Tempo , Reembolso de Seguro de Saúde , Estudos Retrospectivos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/economia , Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia Ambulatorial/economia , Adulto
17.
Brain Behav ; 14(5): e3489, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38688880

RESUMO

OBJECTIVE: To investigate the circadian changes of the autonomic function in patients with zoster-associated pain (ZAP). METHODS: A total of 37 patients with ZAP from April 2022 to October 2022 were enrolled as the observation group, and 37 normal volunteers at the same time were selected as the control group. All participants were required to wear a 24-h Holter, which was used to compare the heart rate variability (HRV) between the two groups. HRV analysis involved time- and frequency-domain parameters. RESULTS: There was no statistically significant difference in general information between two groups. Patients with ZAP had an increased mean heart rate and decreased the standard deviation of normal-to-normal (SDNN) R-R interval, the root mean square of the differences (RMSSD) in successive RR interval, low frequency (LF), and high frequency (HF) compared with control groups in all periods (p < .05). The ratio of LF/HF between two groups had no significant difference (p = .245). SDNN had no significant difference between day and night in the control group (p > .05), whereas SDNN of ZAP patients in night period was reduced than that in day period (p < .001). The level of RMSSD during the day was lower than those at night in the control group (p < .05), whereas no significant difference of RMSSD between two periods was observed in patients with ZAP (p > .05). CONCLUSION: The results of this study indicated that ZAP contributes to the decline of autonomic nervous system (ANS) function, especially parasympathetic components. The patients with ZAP lost parasympathetic advantage and had a worse ANS during the night.


Assuntos
Sistema Nervoso Autônomo , Ritmo Circadiano , Frequência Cardíaca , Herpes Zoster , Humanos , Masculino , Frequência Cardíaca/fisiologia , Feminino , Ritmo Circadiano/fisiologia , Pessoa de Meia-Idade , Sistema Nervoso Autônomo/fisiopatologia , Idoso , Herpes Zoster/fisiopatologia , Herpes Zoster/complicações , Eletrocardiografia Ambulatorial , Adulto
18.
Int J Cardiol ; 406: 132070, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38643802

RESUMO

BACKGROUND: Cardiac involvement represents a major cause of morbidity and mortality in patients with myotonic dystrophy type 1 (DM1) and prevention of sudden cardiac death (SCD) is a central part of patient care. We investigated the natural history of cardiac involvement in patients with DM1 to provide an evidence-based foundation for adjustment of follow-up protocols. METHODS: Patients with genetically confirmed DM1 were identified. Data on patient characteristics, performed investigations (12 lead ECG, Holter monitoring and echocardiography), and clinical outcomes were retrospectively collected from electronic health records. RESULTS: We included 195 patients (52% men) with a mean age at baseline evaluation of 41 years (range 14-79). The overall prevalence of cardiac involvement increased from 42% to 66% after a median follow-up of 10.5 years. There was a male predominance for cardiac involvement at end of follow-up (74 vs. 44%, p < 0.001). The most common types of cardiac involvement were conduction abnormalities (48%), arrhythmias (35%), and left ventricular systolic dysfunction (21%). Only 17% of patients reported cardiac symptoms. The standard 12­lead ECG was the most sensitive diagnostic modality and documented cardiac involvement in 24% at baseline and in 49% at latest follow-up. However, addition of Holter monitoring and echocardiography significantly increased the diagnostic yield with 18 and 13% points at baseline and latest follow-up, respectively. Despite surveillance 35 patients (18%) died during follow-up; seven due to SCD. CONCLUSIONS: In patients with DM1 cardiac involvement was highly prevalent and developed during follow-up. These findings justify lifelong follow-up with ECG, Holter, and echocardiography. CLINICAL PERSPECTIVE: What is new? What are the clinical implications?


Assuntos
Distrofia Miotônica , Humanos , Distrofia Miotônica/complicações , Distrofia Miotônica/diagnóstico , Distrofia Miotônica/fisiopatologia , Distrofia Miotônica/epidemiologia , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Seguimentos , Adulto Jovem , Estudos Retrospectivos , Adolescente , Idoso , Eletrocardiografia Ambulatorial/métodos , Ecocardiografia/métodos , Cardiopatias/etiologia , Cardiopatias/diagnóstico , Cardiopatias/epidemiologia , Eletrocardiografia
19.
Circ Arrhythm Electrophysiol ; 17(5): e012667, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38655693

RESUMO

BACKGROUND: We previously presented the safety and early efficacy of the inspIRE study (Study for Treatment of Paroxysmal Atrial Fibrillation [PAF] by Pulsed-field Ablation [PFA] System With Irreversible Electroporation [IRE]). With the study's conclusion, we report the outcomes of the full pivotal study cohort, with an additional analysis of predictors of success. METHODS: InspIRE was a prospective, multicenter, single-arm clinical trial of drug-refractory paroxysmal atrial fibrillation. Pulmonary vein isolation was performed with a variable-loop circular catheter integrated with a 3-dimensional mapping system. Follow-up with 24-hour Holter was at 3, 6, and 12 months, as well as remote rhythm monitoring: weekly from 3 to 5 months, monthly from 6 to 12 months, and for symptoms. The primary effectiveness end point (PEE) was acute pulmonary vein isolation plus freedom from any atrial arrhythmia at 12 months. Additional subanalyses report predictors of PEE success. RESULTS: The patient cohort included 186 patients: aged 59±10 years, female 30%, and CHA2DS2-VASc 1.3±1.2. The previously reported primary adverse event rate was 0%. One serious procedure-related adverse event, urinary retention, was reported. The PEE was achieved in 75.6% (95% CI, 69.5%-81.8%). The clinical success of freedom from symptomatic recurrence was 81.7% (95% CI, 76.1%-87.2%). Simulating a monitoring method used in standard real-world practice (without protocol-driven remote rhythm monitoring), this translates to a freedom from all and symptomatic recurrence of 85.8% (95% CI, 80.8%-90.9%) or 94.0% (95% CI, 90.6%-97.5%), respectively. Multivariate analyses revealed that left ventricular ejection fraction ≥60% (adjusted odds ratio, 0.30) and patients receiving ≥48 PFA applications (adjusted odds ratio, 0.28) were independent predictors of PEE success. Moreover, PEE success was 79.2% in patients who received ≥12 PFA applications per vein compared with 57.1% in patients receiving fewer PFA applications. CONCLUSIONS: The inspIRE study confirms the safety and effectiveness of pulmonary vein isolation using the novel 3-dimensional mapping integrated circular loop catheter. An optimal number of PFA applications (≥48 total or ≥12 per vein) resulted in an improved 1-year success rate of ≈80%. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04524364.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Feminino , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino , Pessoa de Meia-Idade , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Estudos Prospectivos , Idoso , Fatores de Tempo , Frequência Cardíaca , Potenciais de Ação , Eletrocardiografia Ambulatorial/instrumentação , Recidiva , Cateteres Cardíacos , Valor Preditivo dos Testes , Resultado do Tratamento , Imageamento Tridimensional , Fatores de Risco , Desenho de Equipamento , Técnicas Eletrofisiológicas Cardíacas
20.
J Cardiovasc Med (Hagerstown) ; 25(6): 429-437, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38625830

RESUMO

AIMS: In this study, we investigated a cohort of unselected patients with various indications for an implantable cardiac monitor (ICM). Our main objectives were to determine the incidence of arrhythmic diagnoses, both anticipated and incidental in relation to the ICM indication, and to assess their clinical relevance. METHODS: We examined remote monitoring transmissions from patients with an ICM at four Italian sites to identify occurrences of cardiac arrhythmias. Concurrently, we collected data on medical actions taken in response to arrhythmic findings. RESULTS: The study included 119 patients, with a median follow-up period of 371 days. ICM indications were syncope/presyncope (46.2%), atrial fibrillation management (31.1%), and cryptogenic stroke (22.7%). In the atrial fibrillation management group, atrial fibrillation was the most common finding, with an incidence of 36% [95% confidence interval (CI) 22-55%] at 18 months. Rates of atrial fibrillation were not significantly different between patients with cryptogenic stroke and syncope/presyncope [17% (95% CI 7-40%) vs. 8% (95% CI 3-19%), P  = 0.229].For patients with cryptogenic stroke, the incidence of asystole and bradyarrhythmias at 18 months was 23% (95% CI 11-45%) and 42% (95% CI 24-65%), respectively, similar to estimates obtained for patients implanted for syncope/presyncope ( P  = 0.277 vs. P  = 0.836).Overall, 30 patients (25.2%) required medical intervention following ICM-detected arrhythmias, predominantly involving atrial fibrillation ablation (10.9%) and medication therapy changes (10.1%). CONCLUSION: In a real-life population with heterogeneous insertion indications, approximately 25% of patients received ICM-guided medical interventions within a short timeframe, including treatments for incidental findings. Common incidental arrhythmic diagnoses were bradyarrhythmias in patients with cryptogenic stroke and atrial fibrillation in patients with unexplained syncope.


Assuntos
Arritmias Cardíacas , Fibrilação Atrial , Eletrocardiografia Ambulatorial , Síncope , Humanos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Itália/epidemiologia , Eletrocardiografia Ambulatorial/instrumentação , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/fisiopatologia , Síncope/diagnóstico , Síncope/etiologia , Síncope/epidemiologia , Síncope/terapia , Síncope/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/complicações , Fibrilação Atrial/terapia , Fibrilação Atrial/fisiopatologia , Incidência , Achados Incidentais , Bradicardia/diagnóstico , Bradicardia/epidemiologia , Bradicardia/terapia , Bradicardia/fisiopatologia , Idoso de 80 Anos ou mais , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...