1.
Sci Rep ; 14(1): 15029, 2024 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-38951556

RESUMO

Recent advances in haptic technology could allow haptic hearing aids, which convert audio to tactile stimulation, to become viable for supporting people with hearing loss. A tactile vocoder strategy for audio-to-tactile conversion, which exploits these advances, has recently shown significant promise. In this strategy, the amplitude envelope is extracted from several audio frequency bands and used to modulate the amplitude of a set of vibro-tactile tones. The vocoder strategy allows good consonant discrimination, but vowel discrimination is poor and the strategy is susceptible to background noise. In the current study, we assessed whether multi-band amplitude envelope expansion can effectively enhance critical vowel features, such as formants, and improve speech extraction from noise. In 32 participants with normal touch perception, tactile-only phoneme discrimination with and without envelope expansion was assessed both in quiet and in background noise. Envelope expansion improved performance in quiet by 10.3% for vowels and by 5.9% for consonants. In noise, envelope expansion improved overall phoneme discrimination by 9.6%, with no difference in benefit between consonants and vowels. The tactile vocoder with envelope expansion can be deployed in real-time on a compact device and could substantially improve clinical outcomes for a new generation of haptic hearing aids.


Assuntos
Auxiliares de Audição , Ruído , Percepção da Fala , Humanos , Percepção da Fala/fisiologia , Masculino , Feminino , Adulto , Adulto Jovem , Tato/fisiologia , Estimulação Acústica/métodos , Percepção do Tato/fisiologia , Perda Auditiva/fisiopatologia
2.
Artigo em Chinês | MEDLINE | ID: mdl-38965850

RESUMO

Objectives: To investigate the outcomes of cochlear implantation in Mandarin-speaking cochlear implant (CI) users with single-sided deafness (SSD). Methods: This study was a single-center prospective cohort study. Eleven Mandarin-speaking adult SSD patients who underwent CI implantation at Capital Medical University Beijing Tongren Hospital from August 2020 to October 2021 were recruited, including 6 males and 5 females, with the age ranging from 24 to 50 years old. In a sound field with 7 loudspeakers distributed at 180°, we measured root-mean-square error(RMSE)in SSD patients at the preoperative, 1-month, 3-month, 6-month, and 12-month after switch-on to assess the improvement of sound source localization. The Mandarin Speech Perception (MSP) was used in the sound field to test the speech reception threshold (SRT) of SSD patients under different signal-to-noise locations in a steady-state noise under conditions of CI off and CI on, to reflect the head shadow effect(SSSDNNH), binaural summation effect(S0N0) and squelch effect(S0NSSD). The Tinnitus Handicap Inventory (THI) and the Visual Analogue Scale (VAS) were used to assess changes in tinnitus severity and tinnitus loudness in SSD patients at each time point. The Speech, Spatial and Qualities of Hearing Scale(SSQ) and the Nijmegen Cochlear Implantation Scale (NCIQ) were used to assess the subjective benefits of spatial speech perception and quality of life in SSD patients after cochlear implantation. SPSS 19.0 software was used for statistical analysis. Results: SSD patients showed a significant improvement in the poorer ear in hearing thresholds with CI-on compared with CI-off; The ability to localize the sound source was significantly improved, with statistically significant differences in RMSE at each follow-up time compared with the preoperative period (P<0.05). In the SSSDNNH condition, which reflects the head shadow effect, the SRT in binaural hearing was significantly improved by 6.5 dB compared with unaided condition, and the difference was statistically significant (t=6.25, P=0.001). However, there was no significant improvement in SRT between the binaural hearing condition and unaided conditions in the S0N0 and S0NSSD conditions (P>0.05). The total score of THI and three dimensions were significant decreased (P<0.05). Tinnitus VAS scores were significantly lower in binaural hearing compared to the unaided condition (P<0.001). The total score of SSQ, and the scores of speech and spatial dimensions were significant improved in binaural hearing compared to the unaided condition (P<0.001). There was no statistical difference in NCIQ questionnaire scores between preoperative and postoperative (P>0.05), and only the self-efficacy subscore showed a significant increase(Z=-2.497,P=0.013). Conclusion: CI could help Mandarin-speaking SSD patients restore binaural hearing to some extent, improve sound localization and speech recognition in noise. In addition, CI in SSD patients could suppress tinnitus, reduce the loudness of tinnitus, and improve subjective perceptions of spatial hearing and quality of life.


Assuntos
Implante Coclear , Humanos , Masculino , Feminino , Implante Coclear/métodos , Adulto , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Perda Auditiva Unilateral/cirurgia , Implantes Cocleares , Percepção da Fala , Adulto Jovem , Localização de Som , Zumbido/cirurgia , Surdez/cirurgia , Auxiliares de Audição
6.
Front Public Health ; 12: 1364000, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38873313

RESUMO

Background: Access to audiology services for older adults residing in sparsely populated regions is often limited compared to those in central urban areas. The geographic accessibility to follow-up care, particularly the influence of distance, may contribute to an increased risk of hearing aid abandonment. Objective: To assess the association between the home-to-healthcare-calibration-center distance and hearing aid abandonment among older adults fitted in the Chilean public health system. Methods: 455 patients who received hearing aids from two public hospitals in two regions were considered. Univariate and multivariate Poisson regression models with robust variance estimation were used to analyze the association between the geographical distance and hearing aid abandonment, accounting for confounding effects. Results: Approximately 18% of the sample abandoned the hearing aid, and around 50% reported using the hearing aid every day. A twofold increase in distance between home and the hearing center yielded a 35% (RR = 1.35; 95% CI: 1.04-1.74; p = 0.022) increased risk of hearing aid abandonment. Also, those in the second quintile had a 2.17 times the risk of abandoning the hearing aid compared to the first quintile (up to 2.3 km). Under the assumption that patients reside within the first quintile of distance, a potential reduction of 45% in the incidence of hearing aid abandonment would be observed. The observed risk remained consistent across different statistical models to assess sensitivity. Conclusion: A higher distance between the residence and the healthcare center increases hearing aid abandonment risk. The association may be explained by barriers in purchasing supplies required to maintain the device (batteries, cleaning elements, potential repairs, or maintenance).


Assuntos
Acessibilidade aos Serviços de Saúde , Auxiliares de Audição , Humanos , Auxiliares de Audição/estatística & dados numéricos , Feminino , Idoso , Masculino , Acessibilidade aos Serviços de Saúde/estatística & dados numéricos , Idoso de 80 Anos ou mais , Chile , Perda Auditiva/reabilitação
7.
J Korean Med Sci ; 39(23): e179, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38887200

RESUMO

BACKGROUND: This study compared hearing outcomes with use of personal sound amplification products (PSAPs) and hearing aids (HAs) in patients with moderate to moderately severe unilateral hearing loss. METHODS: Thirty-nine participants were prospectively enrolled, and randomly assigned to use either one HA (basic or premium type) or one PSAP (basic or high-end type) for the first 8 weeks and then the other device for the following 8 weeks. Participants underwent a battery of examinations at three visits, including sound-field audiometry, word recognition score (WRS), speech perception in quiet and in noise, real-ear measurement, and self-report questionnaires. RESULTS: Functional gain was significantly higher with HAs across all frequencies (P < 0.001). While both PSAPs and HAs improved WRS from the unaided condition, HAs were superior to PSAPs. The speech recognition threshold in quiet conditions and signal-to-noise ratio in noisy conditions were significantly lower in the HA-aided condition than in the PSAP-aided condition, and in the PSAP-aided condition than in the unaided condition. Subjective satisfaction also favored HAs than PSAPs in questionnaires, Abbreviated Profile of Hearing Aid Benefit, International Outcome Inventory for Hearing Aids, and Host Institutional Questionnaire. CONCLUSION: While PSAPs provide some benefit for moderate to moderately severe unilateral hearing loss, HAs are more effective. This underscores the potential role of PSAPs as an accessible, affordable first-line intervention in hearing rehabilitation, particularly for individuals facing challenges in accessing conventional HAs.


Assuntos
Estudos Cross-Over , Auxiliares de Audição , Perda Auditiva Unilateral , Percepção da Fala , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Prospectivos , Inquéritos e Questionários , Perda Auditiva Unilateral/reabilitação , Idoso , Adulto , Satisfação do Paciente , Ruído , Razão Sinal-Ruído
8.
Noise Health ; 26(121): 220-225, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38904826

RESUMO

AIMS: Digital noise reduction (DNR) minimizes the effect of noise on speech signals by continuously monitoring frequency bands in the presence of noise. In the present study, we explored the effect of DNR technology on speech intelligibility in individuals using hearing aids (HAs) and investigated implications for daily use. METHODS AND MATERIAL: Eighteen participants with bilateral moderate sensorineural hearing loss (aged 16-45 years) were included. Bilateral receiver-in-the-ear HAs were fitted in the participants. The adaptive and nonadaptive (with a signal-to-noise ratio (SNR) of +5 and -5 dB, respectively) Turkish matrix sentence test (TURMatrix) in noise and free-field hearing assessments, including hearing thresholds with hearing aids, speech recognition thresholds (SRT), and speech discrimination scores, were conducted in two different conditions: HA in the DNR-on and DNR-off conditions. RESULTS: No significant difference was observed between free-field hearing assessments with the HA in the DNR-off and DNR-on conditions (P > 0.05). Furthermore, the adaptive and nonadaptive TURMatrix revealed significant differences between the scores under the DNR-on and DNR-off conditions (P < 0.05). Nevertheless, under the DNR-on condition, there was no correlation between free-field hearing assessments with HA and TURMatrix results (P > 0.05). However, a significant correlation was observed between SRT scores with HA and TURMatrix scores (adaptive and nonadaptive, +5 and -5 dB SNR, respectively) under the DNR-off condition (P < 0.05). CONCLUSION: Our study findings suggest that DNR can improve speech intelligibility in noisy environments. Therefore, DNR can enhance an individual's auditory comfort by improving their capacity to grasp speech in background noise.


Assuntos
Auxiliares de Audição , Perda Auditiva Neurossensorial , Ruído , Inteligibilidade da Fala , Humanos , Adulto , Masculino , Pessoa de Meia-Idade , Perda Auditiva Neurossensorial/reabilitação , Feminino , Adulto Jovem , Adolescente , Razão Sinal-Ruído , Limiar Auditivo , Percepção da Fala , Teste do Limiar de Recepção da Fala
9.
Trends Hear ; 28: 23312165241259704, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38835268

RESUMO

The use of in-situ audiometry for hearing aid fitting is appealing due to its reduced resource and equipment requirements compared to standard approaches employing conventional audiometry alongside real-ear measures. However, its validity has been a subject of debate, as previous studies noted differences between hearing thresholds measured using conventional and in-situ audiometry. The differences were particularly notable for open-fit hearing aids, attributed to low-frequency leakage caused by the vent. Here, in-situ audiometry was investigated for six receiver-in-canal hearing aids from different manufacturers through three experiments. In Experiment I, the hearing aid gain was measured to investigate whether corrections were implemented to the prescribed target gain. In Experiment II, the in-situ stimuli were recorded to investigate if corrections were directly incorporated to the delivered in-situ stimulus. Finally, in Experiment III, hearing thresholds using in-situ and conventional audiometry were measured with real patients wearing open-fit hearing aids. Results indicated that (1) the hearing aid gain remained unaffected when measured with in-situ or conventional audiometry for all open-fit measurements, (2) the in-situ stimuli were adjusted for up to 30 dB at frequencies below 1000 Hz for all open-fit hearing aids except one, which also recommends the use of closed domes for all in-situ measurements, and (3) the mean interparticipant threshold difference fell within 5 dB for frequencies between 250 and 6000 Hz. The results clearly indicated that modern measured in-situ thresholds align (within 5 dB) with conventional thresholds measured, indicating the potential of in-situ audiometry for remote hearing care.


Assuntos
Limiar Auditivo , Auxiliares de Audição , Humanos , Estimulação Acústica , Ajuste de Prótese/métodos , Reprodutibilidade dos Testes , Audiometria/métodos , Audiometria de Tons Puros , Perda Auditiva/diagnóstico , Perda Auditiva/reabilitação , Perda Auditiva/fisiopatologia , Audição , Valor Preditivo dos Testes , Pessoas com Deficiência Auditiva/reabilitação , Pessoas com Deficiência Auditiva/psicologia , Desenho de Equipamento , Masculino , Feminino
10.
Trends Hear ; 28: 23312165241260029, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38831646

RESUMO

The extent to which active noise cancelation (ANC), when combined with hearing assistance, can improve speech intelligibility in noise is not well understood. One possible source of benefit is ANC's ability to reduce the sound level of the direct (i.e., vent-transmitted) path. This reduction lowers the "floor" imposed by the direct path, thereby allowing any increases to the signal-to-noise ratio (SNR) created in the amplified path to be "realized" at the eardrum. Here we used a modeling approach to estimate this benefit. We compared pairs of simulated hearing aids that differ only in terms of their ability to provide ANC and computed intelligibility metrics on their outputs. The difference in metric scores between simulated devices is termed the "ANC Benefit." These simulations show that ANC Benefit increases as (1) the environmental sound level increases, (2) the ability of the hearing aid to improve SNR increases, (3) the strength of the ANC increases, and (4) the hearing loss severity decreases. The predicted size of the ANC Benefit can be substantial. For a moderate hearing loss, the model predicts improvement in intelligibility metrics of >30% when environments are moderately loud (>70 dB SPL) and devices are moderately capable of increasing SNR (by >4 dB). It appears that ANC can be a critical ingredient in hearing devices that attempt to improve SNR in loud environments. ANC will become more and more important as advanced SNR-improving algorithms (e.g., artificial intelligence speech enhancement) are included in hearing devices.


Assuntos
Auxiliares de Audição , Ruído , Mascaramento Perceptivo , Razão Sinal-Ruído , Inteligibilidade da Fala , Percepção da Fala , Humanos , Ruído/efeitos adversos , Simulação por Computador , Estimulação Acústica , Correção de Deficiência Auditiva/instrumentação , Pessoas com Deficiência Auditiva/reabilitação , Pessoas com Deficiência Auditiva/psicologia , Perda Auditiva/diagnóstico , Perda Auditiva/reabilitação , Perda Auditiva/fisiopatologia , Desenho de Equipamento , Processamento de Sinais Assistido por Computador
11.
Otol Neurotol ; 45(6): 676-683, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38865727

RESUMO

HYPOTHESIS: Resonance frequency analysis (RFA) is a reliable, noninvasive method to assess the stability of bone-anchored hearing implants (BAHIs), although surgical-, implant-, and host-related factors can affect its outcome. BACKGROUND: BAHI plays an important role in restoring hearing function. However, implant- and host-related factors contribute to premature implant extrusion. To mitigate this, noninvasive methods to assess implant stability, along with a better understanding of factors contributing to BAHI failure, are needed. METHODS: We evaluated the utility of RFA to quantify implant stability in sawbone (bone mimicking material), 29 human cadaveric samples, and a prospective cohort of 29 pediatric and 27 adult participants, and identified factors associated with implant stability. To validate the use of RFA in BAHI, we compared RFA-derived implant stability quotient (ISQ) estimates to peak loads obtained from mechanical push-out testing. RESULTS: ISQ and peak loads were significantly correlated (Spearman rho = 0.48, p = 0.0088), and ISQ reliably predicted peak load up to 1 kN. We then showed that in cadaveric samples, abutment length, internal table bone volume, and donor age were significantly associated with implant stability. We validated findings in our prospective patient cohort and showed that minimally invasive Ponto surgery (MIPS; versus linear incision), longer implantation durations (>16 wk), older age (>25 yr), and shorter abutment lengths (≤10 mm) were associated with better implant stability. Finally, we characterized the short-term reproducibility of ISQ measurements in sawbone and patient implants. CONCLUSIONS: Together, our findings support the use of ISQ as a measure of implant stability and emphasize important considerations that impact implant stability, including surgical method, implant duration, age, and abutment lengths.


Assuntos
Auxiliares de Audição , Análise de Frequência de Ressonância , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Criança , Adolescente , Estudos Prospectivos , Prótese Ancorada no Osso , Adulto Jovem , Idoso , Âncoras de Sutura , Cadáver
12.
J Int Med Res ; 52(6): 3000605241232549, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38861681

RESUMO

OBJECTIVE: To investigate which factors influence the adherence to hearing aid (HA) use in elderly patients with moderate-to-severe hearing loss. METHODS: This observational, prospective, single-centre study enrolled patients with moderate-to-severe hearing loss. They were evaluated before and 1 year after having either one or two HAs fitted. RESULTS: A total of 86 patients were enrolled in the study and of these 69.8% (60 of 86; USER group) continued to use their HA at 1 year after fitting; six patients had not continued their use (NON-USERS). The USER group was younger than the NON-USER group, but the difference was not significant. The USER group had a significantly better unaided auditory threshold at baseline than the NON-USER group. HA use resulted in improvements in speech audiometry and auditory threshold. There was also a maintenance of cognitive function in the USER group. CONCLUSION: Use of HA for 1 year resulted in improved auditory performance and an absence of a deterioration of cognitive function.Trial registration: This research was retrospectively registered under no. NCT04333043 at ClinicalTrials.gov (http://www.clinicaltrials.gov/) on the 26 March 2020. This research has been registered with the Ethics Committee of the Area Vasta Emilia Nord under number 104, date of approval 17/07/2017.


Assuntos
Auxiliares de Audição , Perda Auditiva , Cooperação do Paciente , Humanos , Feminino , Masculino , Idoso , Estudos Prospectivos , Perda Auditiva/fisiopatologia , Idoso de 80 Anos ou mais , Limiar Auditivo/fisiologia , Pessoa de Meia-Idade , Cognição/fisiologia
13.
Sci Prog ; 107(2): 368504241262195, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38872447

RESUMO

A vestibular schwannoma is a benign tumor; however, the schwannoma itself and interventions can cause sensorineural hearing loss. Most vestibular schwannomas are unilateral tumors that affect hearing only on one side. Attention has focused on improving the quality of life for patients with unilateral hearing loss and therapeutic interventions to address this issue have been emphasized. Herein, we encountered a patient who was a candidate for hearing preservation surgery based on preoperative findings and had nonserviceable hearing after the surgery, according to the Gardner-Robertson classification. Postoperatively, the patient had decreased listening comprehension and ability to localize sound sources. He was fitted with bilateral hearing aids, and his ability to localize sound sources improved. Although the patient had postoperative nonserviceable hearing on the affected side and age-related hearing loss on the unaffected side, hearing aids in both ears were useful for his daily life. Therefore, the patient was able to maintain a binaural hearing effect and the ability to localize the sound source improved. This report emphasizes the importance of hearing preservation with vestibular schwannomas, and the demand for hearing loss rehabilitation as a postoperative complication can increase, even if hearing loss is nonserviceable.


Assuntos
Auxiliares de Audição , Neuroma Acústico , Humanos , Neuroma Acústico/cirurgia , Masculino , Pessoa de Meia-Idade , Perda Auditiva Neurossensorial/cirurgia , Perda Auditiva Neurossensorial/reabilitação , Perda Auditiva Neurossensorial/etiologia , Qualidade de Vida , Perda Auditiva/etiologia , Perda Auditiva/cirurgia , Perda Auditiva/reabilitação , Complicações Pós-Operatórias/etiologia
14.
J Acoust Soc Am ; 155(6): 3957-3967, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38921646

RESUMO

High-frequency speech information is susceptible to inaccurate perception in even mild to moderate forms of hearing loss. Some hearing aids employ frequency-lowering methods such as nonlinear frequency compression (NFC) to help hearing-impaired individuals access high-frequency speech information in more accessible lower-frequency regions. As such techniques cause significant spectral distortion, tests such as the S-Sh Confusion Test help optimize NFC settings to provide high-frequency audibility with the least distortion. Such tests have been traditionally based on speech contrasts pertinent to English. Here, the effects of NFC processing on fricative perception between English and Mandarin listeners are assessed. Small but significant differences in fricative discrimination were observed between the groups. The study demonstrates possible need for language-specific clinical fitting procedures for NFC.


Assuntos
Auxiliares de Audição , Percepção da Fala , Humanos , Feminino , Masculino , Adulto , Adulto Jovem , Idioma , Estimulação Acústica , Acústica da Fala , Limiar Auditivo
15.
Int J Pediatr Otorhinolaryngol ; 181: 111989, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38805933

RESUMO

BACKGROUND: Pandemic public health measures, such as masks and social distancing, present unique challenges for people who are hard-of-hearing. This study sought to understand how adolescents with varying levels of hearing loss would describe their experiences communicating in a classroom environment during a pandemic and its associated public health measures. METHODS: Qualitative study utilizing one-on-one semi-structured interviews conducted from July 2021 to April 2022. Interviews were transcribed and analyzed using a reflexive thematic analysis to conceptualize the main themes from the data. Adolescents ages 12-17 who attended school in person during the COVID-19 pandemic with either normal hearing or; bilateral cochlear implants or; bone-anchored hearing aids or; unilateral moderate to severe (40-70 dB) conductive hearing loss secondary to mastoidectomy, were interviewed. Participants were recruited from BC Children's Hospital Otolaryngology clinic via a convenience sample. RESULTS: Fourteen adolescents were interviewed with a median age of 15, 9 with hearing loss and 5 with normal hearing. Pandemic associated challenges such as masks muffling speech, protocol fatigue, and missing pre-pandemic life were present in both the hearing loss and normal hearing groups. Classroom communication for adolescents with hearing loss was disproportionately affected by pandemic measures, leading to challenges making friends, feeling behind their peers in learning, and listening fatigue. Resilience was noted among adolescents with hearing loss in their ability to adapt to pandemic measures and changing classroom dynamics. For adolescents with unilateral hearing loss, the pandemic provided an improved listening environment via a reduction in background noise. CONCLUSION: Pre-existing classroom communication challenges for adolescents with hearing loss were amplified under pandemic public health measures and shared, in part, by those with normal hearing. These findings can be used to further inform classroom design to the optimize learning environment for deaf and hard of hearing students.


Assuntos
COVID-19 , Pesquisa Qualitativa , Humanos , Adolescente , COVID-19/prevenção & controle , COVID-19/epidemiologia , Masculino , Feminino , Criança , Comunicação , SARS-CoV-2 , Perda Auditiva/psicologia , Pandemias , Instituições Acadêmicas , Implantes Cocleares , Máscaras , Auxiliares de Audição , Entrevistas como Assunto
16.
Ear Hear ; 45(4): 837-849, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38768048

RESUMO

OBJECTIVE: Children with hearing loss experience greater difficulty understanding speech in the presence of noise and reverberation relative to their normal hearing peers despite provision of appropriate amplification. The fidelity of fundamental frequency of voice (f0) encoding-a salient temporal cue for understanding speech in noise-could play a significant role in explaining the variance in abilities among children. However, the nature of deficits in f0 encoding and its relationship with speech understanding are poorly understood. To this end, we evaluated the influence of frequency-specific f0 encoding on speech perception abilities of children with and without hearing loss in the presence of noise and/or reverberation. METHODS: In 14 school-aged children with sensorineural hearing loss fitted with hearing aids and 29 normal hearing peers, envelope following responses (EFRs) were elicited by the vowel /i/, modified to estimate f0 encoding in low (<1.1 kHz) and higher frequencies simultaneously. EFRs to /i/ were elicited in quiet, in the presence of speech-shaped noise at +5 dB signal to noise ratio, with simulated reverberation time of 0.62 sec, as well as both noise and reverberation. EFRs were recorded using single-channel electroencephalogram between the vertex and the nape while children watched a silent movie with captions. Speech discrimination accuracy was measured using the University of Western Ontario Distinctive Features Differences test in each of the four acoustic conditions. Stimuli for EFR recordings and speech discrimination were presented monaurally. RESULTS: Both groups of children demonstrated a frequency-dependent dichotomy in the disruption of f0 encoding, as reflected in EFR amplitude and phase coherence. Greater disruption (i.e., lower EFR amplitudes and phase coherence) was evident in EFRs elicited by low frequencies due to noise and greater disruption was evident in EFRs elicited by higher frequencies due to reverberation. Relative to normal hearing peers, children with hearing loss demonstrated: (a) greater disruption of f0 encoding at low frequencies, particularly in the presence of reverberation, and (b) a positive relationship between f0 encoding at low frequencies and speech discrimination in the hardest listening condition (i.e., when both noise and reverberation were present). CONCLUSIONS: Together, these results provide new evidence for the persistence of suprathreshold temporal processing deficits related to f0 encoding in children despite the provision of appropriate amplification to compensate for hearing loss. These objectively measurable deficits may underlie the greater difficulty experienced by children with hearing loss.


Assuntos
Perda Auditiva Neurossensorial , Ruído , Percepção da Fala , Humanos , Percepção da Fala/fisiologia , Criança , Masculino , Feminino , Perda Auditiva Neurossensorial/fisiopatologia , Perda Auditiva Neurossensorial/reabilitação , Auxiliares de Audição , Estudos de Casos e Controles , Adolescente , Eletroencefalografia
17.
J Speech Lang Hear Res ; 67(6): 1868-1885, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38718262

RESUMO

PURPOSE: This report describes a hearing device and corresponding fitting protocol designed for use in a transitional intervention for debilitating loudness-based hyperacusis. METHOD: The intervention goal is to transition patients with hyperacusis from their typical counterproductive sound avoidance behaviors (i.e., sound attenuation and limited exposure to healthy low-level sounds) into beneficial sound therapy treatment that can expand their dynamic range to the point where they can tolerate everyday sounds and experience an improved quality of life. This requires a combination of counseling and sound therapy, the latter of which is provided via the hearing device technology, signal processing, and precision fitting approach described in this report. The device combines a miniature behind-the-ear sound processor and a custom earpiece designed to maximize the attenuation of external sounds. Output-limiting loudness suppression is used to restrict exposure to offending high-level sounds while unity gain amplification maximizes exposure to healthy and tolerable lower level sounds. The fitting process includes measurement of the real-ear unaided response, the real-ear measurement (REM) system noise floor, the real-ear occluded response, real-ear insertion gain, and the output limit. With these measurements, the device can achieve the prescribed unity gain needed to provide transparent access to comfortable sound levels. It also supports individualized configuration of the therapeutic noise from an on-board sound generator and adaptive output limiting based on treatment-induced increases in dynamic range. RESULTS AND CONCLUSION: The utility of this device and fitting protocol, in combination with structured counseling, is highlighted in the outcomes of a successful 6-month trial of the transitional intervention described in a companion report in this issue.


Assuntos
Auxiliares de Audição , Hiperacusia , Humanos , Hiperacusia/terapia , Percepção Sonora , Desenho de Equipamento , Qualidade de Vida
18.
Otol Neurotol ; 45(6): 696-702, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38769078

RESUMO

OBJECTIVE: To investigate the microbial changes of long-term hearing aid use culture independently. STUDY DESIGN: Cross-sectional study. PATIENTS: Fifty long-term hearing aid users and 80 volunteer controls with asymptomatic ears. INTERVENTION: External auditory canal (EAC) sampling with DNA-free swabs. MAIN OUTCOME MEASURES: Microbial communities in the samples were investigated with amplicon sequencing of the 16S rRNA gene. RESULTS: The final analysis contained 48 hearing aid users, 59 controls. Twenty-four samples were excluded because of low sequence count, recent use of antimicrobials and/or corticosteroids, recent cold, or missing health status. The groups showed significant differences in bacterial diversity (beta div., p = 0.011), and hearing aid users showed lower species richness than the control group (alpha div., p < 0.01). The most frequent findings in both groups were Staphylococcus auricularis , Alloiococcus otitis , Cutibacterium acnes , Corynebacterium otitidis , and Staphylococcus unclassified sp. Hearing aid users' samples presented more Corynebacterium tuberculostearicum than the control samples. Common EAC pathogens, such as Staphylococcus aureus or Pseudomonas aeruginosa were rare. CONCLUSION: Long-term hearing aid use lowers bacterial diversity and modulates the EAC microbiome. The changes mostly affect commensals. Lowered diversity may predispose individuals to EAC conditions and needs more research.


Assuntos
Meato Acústico Externo , Auxiliares de Audição , Microbiota , Humanos , Masculino , Meato Acústico Externo/microbiologia , Idoso , Feminino , Pessoa de Meia-Idade , Estudos Transversais , RNA Ribossômico 16S/genética , Idoso de 80 Anos ou mais , Adulto , Bactérias/genética , Bactérias/isolamento & purificação
19.
Otol Neurotol ; 45(6): 635-642, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38769110

RESUMO

OBJECTIVE: To investigate if cartilage conduction (CC) rerouting devices are noninferior to air-conduction (AC) rerouting devices for single-sided deafness (SSD) patients by measuring objective and subjective performance using speech-in-noise tests that resemble a realistic hearing environment, sound localization tests, and standardized questionnaires. STUDY DESIGN: Prospective, single-subject randomized, crossover study. SETTING: Anechoic room inside a university. PATIENTS: Nine adults between 21 and 58 years of age with severe or profound unilateral sensorineural hearing loss. INTERVENTIONS: Patients' baseline hearing was assessed; they then used both the cartilage conduction contralateral routing of signals device (CC-CROS) and an air-conduction CROS hearing aid (AC-CROS). Patients wore each device for 2 weeks in a randomly assigned order. MAIN OUTCOME MEASURES: Three main outcome measures were 1) speech-in-noise tests, measuring speech reception thresholds; 2) proportion of correct sound localization responses; and 3) scores on the questionnaires, "Abbreviated Profile of Hearing Aid Benefit" (APHAB) and "Speech, Spatial, and Qualities of Hearing Scale" with 12 questions (SSQ-12). RESULTS: Speech reception threshold improved significantly when noise was ambient, and speech was presented from the front or the poor-ear side with both CC-CROS and AC-CROS. When speech was delivered from the better-ear side, AC-CROS significantly improved performance, whereas CC-CROS had no significant effect. Both devices mainly worsened sound localization, whereas the APHAB and SSQ-12 scores showed benefits. CONCLUSION: CC-CROS has noninferior hearing-in-noise performance except when the speech was presented to the better ear under ambient noise. Subjective measures showed that the patients realized the effectiveness of both devices.


Assuntos
Condução Óssea , Estudos Cross-Over , Auxiliares de Audição , Perda Auditiva Neurossensorial , Localização de Som , Percepção da Fala , Humanos , Adulto , Pessoa de Meia-Idade , Masculino , Feminino , Localização de Som/fisiologia , Condução Óssea/fisiologia , Perda Auditiva Neurossensorial/fisiopatologia , Perda Auditiva Neurossensorial/reabilitação , Percepção da Fala/fisiologia , Inquéritos e Questionários , Estudos Prospectivos , Perda Auditiva Unilateral/fisiopatologia , Perda Auditiva Unilateral/reabilitação , Adulto Jovem , Ruído , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...