Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.924
Filtrar
1.
Sultan Qaboos Univ Med J ; 24(2): 250-258, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38828246

RESUMO

Objectives: Cranioplasty is a complex craniofacial and neurosurgical procedure that aims to reinstate the architecture of the cranial vault and elevate both its aesthetic and neurological function. Several reconstructive materials have been thoroughly explored in the search for the optimal solution for cranioplasty. This study aimed to evaluate different material used for cranial reconstruction in Oman. Methods: This retrospective study included all patients who had had cranioplasty procedures performed at Khoula Hospital, Muscat, Oman, from 2012 to 2022. Demographic information, the characteristics of the cranial defect and any complications that occurred post-operatively were analysed. Results: A total of 47 patients were included in this study. The most common cause of cranial defects was craniectomy following traumatic head injury (70.2%) along with excision of fibrous dysplasia (10.6%). The most frequently utilised material for cranial repair was autologous bone grafts (n = 28), followed by polyetheretherketone (PEEK; n = 14). Interestingly, the replacement of bone grafts from previous craniectomy showed a notably high resorption rate (71.4%), in contrast to split calvarial grafts (0%) and other types of bone grafts (14.3%). Additionally, delayed graft infection was observed in 3.6% of the bone graft group and 7.1% of the PEEK group. Conclusion: Patient-specific alloplastic implants such as PEEK have gained popularity for large and complex cranioplasty, as they provide excellent aesthetic outcomes and leave no donor site morbidity. In contrast, bone grafts remain the gold standard for small to medium-sized cranial defects.


Assuntos
Procedimentos de Cirurgia Plástica , Humanos , Omã/epidemiologia , Estudos Retrospectivos , Masculino , Feminino , Adulto , Procedimentos de Cirurgia Plástica/métodos , Procedimentos de Cirurgia Plástica/estatística & dados numéricos , Pessoa de Meia-Idade , Adolescente , Crânio/cirurgia , Criança , Transplante Ósseo/métodos , Transplante Ósseo/estatística & dados numéricos , Polímeros/uso terapêutico , Benzofenonas , Idoso , Pré-Escolar
2.
Medicine (Baltimore) ; 103(25): e38431, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38905365

RESUMO

BACKGROUND: The research focused on the postoperative effect of using interbody fusion cage in lumbar posterior lamina decompression and interbody fusion with pedicle screw by comparing the postoperative effect of using 3D printing (Ti6Al4V) and PEEK material interbody fusion cage. METHODS: Ninety-one patients with lumbar degenerative diseases from the Department of Spine Surgery of Tianjin Hospital were included in the study cohort. They were divided into 3D group (n = 39) and PEEK group (n = 52) according to the use of interbody fusion cage. The imaging data of the patients were collected and the postoperative data of the 2 groups were compared to evaluate patients' health status and the recovery of lumbar structure and function after operation. RESULTS: Combined with the degree of fusion, the clinical effect of 3D printing titanium alloy interbody fusion cage was comprehensively judged. At the last follow-up, the JOA score, ODI index, VAS, prolo function score, and SF-36 scale of the 2 groups showed that the clinical symptoms were better than those before operation (P < .05). The height of intervertebral disc, the area of intervertebral foramen and the physiological curvature of lumbar vertebrae increased in varying degrees after operation (P < .05). At the last follow-up, the vertebral cage fusion rates were as high as 89.13% and 90.91% in the 3D and PEEK groups, with collapse rates of 6.5% and 4.5%, respectively. There were 10 cases of cage displacement in 3D group and 7 cases of cage displacement in PEEK group. There was no significant difference between the 2 groups (P > .05). CONCLUSIONS: In conclusion, 3D printed (Ti6Al4V) interbody fusion cage can obtain good clinical effect in the surgical treatment of lumbar degenerative diseases. Posterior lumbar lamina decompression, bilateral pedicle screw fixation combined with 3D printed cage interbody fusion is excellent in rebuilding the stability of lumbar vertebrae. 3D printed interbody fusion cage can be an ideal substitute material for intervertebral bone grafting. The stable fusion time of interbody fusion cage after lumbar fusion is mostly from 3 months to half a year after operation.


Assuntos
Ligas , Vértebras Lombares , Impressão Tridimensional , Fusão Vertebral , Titânio , Humanos , Fusão Vertebral/métodos , Fusão Vertebral/instrumentação , Masculino , Vértebras Lombares/cirurgia , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Parafusos Pediculares , Benzofenonas , Polímeros , Idoso , Polietilenoglicóis , Cetonas , Resultado do Tratamento , Descompressão Cirúrgica/métodos , Descompressão Cirúrgica/instrumentação , Adulto , Degeneração do Disco Intervertebral/cirurgia
3.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(3): 251-256, 2024 May 30.
Artigo em Chinês | MEDLINE | ID: mdl-38863089

RESUMO

Polyetheretherketone (PEEK) has emerged as a thermoplastic material of choice in the realm of implantable medical devices, owing to its high biocompatibility and exceptional mechanical strength. Despite its promise for custom-made medical devices, 3D-printed PEEK in orthopedics, trauma, and spinal implants has not yet achieved widespread application. This study outlines the properties of PEEK, 3D-printed PEEK-based composites, and their utilization in implantable medical devices, thereby fostering the development and regulation of next-generation medical devices.


Assuntos
Benzofenonas , Materiais Biocompatíveis , Cetonas , Polietilenoglicóis , Polímeros , Impressão Tridimensional , Próteses e Implantes , Humanos
4.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(3): 237-244, 2024 May 30.
Artigo em Chinês | MEDLINE | ID: mdl-38863087

RESUMO

Additive manufacturing (3D printing) technology aligns with the direction of precision and customization in future medicine, presenting a significant opportunity for innovative development in high-end medical devices. Currently, research and industrialization of 3D printed medical devices mainly focus on nondegradable implants and degradable implants. Primary areas including metallic orthopaedic implants, polyether-ether-ketone (PEEK) bone implants, and biodegradable implants have been developed for clinical and industrial application. Recent research achievements in these areas are reviewed, with a discussion on the additive manufacturing technologies and applications for customized implants. Challenges faced by different types of implants are analyzed from technological, application, and regulatory perspectives. Furthermore, prospects and suggestions for future development are outlined.


Assuntos
Impressão Tridimensional , Próteses e Implantes , Benzofenonas , Polímeros , Humanos , Cetonas , Desenho de Prótese , Materiais Biocompatíveis , Polietilenoglicóis , Implantes Absorvíveis
5.
Environ Int ; 189: 108797, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38838486

RESUMO

Benzophenone (BP)-type UV filters are commonly added to sunscreens and cosmetics to protect against UV radiation for human skin and hair. As a result, BPs are ubiquitous in the environment and human body, and their endocrine-disrupting characteristics have been a hot topic of discussion. However, our knowledge regarding the detrimental effects of prenatal exposure to BPs on pregnant women and their offspring remains limited. To fill this gap, we determined five BP derivatives in 600 serum samples obtained from pregnant women. All the target analytes, except 2,4-dihydroxybenzophenone (BP-1), have achieved a 100 % detection rate. The most prevalent compound was 2-hydroxy-4-methoxybenzophenone (BP-3), with a median concentration of 0.545 ng/mL. Significant and positive correlations were observed among BP derivatives, indicating both endogenous metabolism and common external sources. Utilizing Bayesian kernel machine regression (BKMR) and quantile-based g-computation (QGC) models, we found relationships between BP exposure and reduced neonatal birth weight (BW) and birth chest circumference (BC) during the third trimester. Notably, the adverse effect of BPs on birth size was sex-specific. Moreover, triglyceride (TG) was identified as a potential mediator of the effect of BPs on blood pressure, and co-exposure to BPs was linked to disruptions in thyroid hormone levels and glucose regulation. Further research is warranted to unravel the toxicity of BPs and their detrimental effects on pregnant women and fetuses.


Assuntos
Benzofenonas , Exposição Materna , Protetores Solares , Humanos , Feminino , Gravidez , China , Adulto , Recém-Nascido , Saúde Materna , Peso ao Nascer/efeitos dos fármacos , Efeitos Tardios da Exposição Pré-Natal , Masculino , Adulto Jovem
6.
Cells ; 13(12)2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38920673

RESUMO

In the context of glaucoma, intraocular pressure (IOP) and age are recognized as the primary factors contributing to its onset and progression. However, significant reductions in IOP fail to completely halt its advancement. An emerging body of literature highlights the role of neuroinflammation in glaucoma. This study aimed to explore Bromfenac's anti-inflammatory properties in mitigating neuroinflammation associated with glaucoma using an ischemia-reperfusion (IR) glaucoma model. Bromfenac's impact on microglia and astrocytes under pressure was assessed via Western blotting and an enzyme-linked immunosorbent assay. Immunohistochemical staining was used to evaluate glial activation and changes in inflammatory marker expression in the IR model. Bromfenac led to the downregulation of inflammatory markers, which were elevated in the conditions of elevated pressure, and necroptosis markers were downregulated in astrocytes. In the IR model, elevated levels of GFAP and Iba-1 indicated glial activation. Following Bromfenac administration, levels of iNOS, COX-2, and PGE2-R were reduced, suggesting a decrease in neuroinflammation. Furthermore, Bromfenac administration in the IR model resulted in the improved survival of retinal ganglion cells (RGCs) and preservation of retinal function, as demonstrated by immunohistochemical staining and electroretinography. In summary, Bromfenac proved effective in diminishing neuroinflammation and resulted in enhanced RGC survival.


Assuntos
Astrócitos , Benzofenonas , Bromobenzenos , Modelos Animais de Doenças , Glaucoma , Traumatismo por Reperfusão , Bromobenzenos/farmacologia , Bromobenzenos/uso terapêutico , Animais , Benzofenonas/farmacologia , Benzofenonas/uso terapêutico , Traumatismo por Reperfusão/tratamento farmacológico , Traumatismo por Reperfusão/patologia , Traumatismo por Reperfusão/complicações , Glaucoma/tratamento farmacológico , Glaucoma/patologia , Glaucoma/complicações , Astrócitos/efeitos dos fármacos , Astrócitos/metabolismo , Astrócitos/patologia , Doenças Neuroinflamatórias/tratamento farmacológico , Doenças Neuroinflamatórias/patologia , Células Ganglionares da Retina/efeitos dos fármacos , Células Ganglionares da Retina/patologia , Células Ganglionares da Retina/metabolismo , Microglia/efeitos dos fármacos , Microglia/metabolismo , Microglia/patologia , Masculino , Pressão Intraocular/efeitos dos fármacos , Ratos
7.
BMC Musculoskelet Disord ; 25(1): 488, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38909212

RESUMO

PURPOSE: To analyze the characteristics of PEEK rods retrieved in vivo, specifically their wear and deformation, biodegradability, histocompatibility, and mechanical properties. METHOD: Six PEEK rods were retrieved from revision surgeries along with periprosthetic tissue. The retrieved PEEK rods were evaluated for surface damage and internal changes using Micro-CT, while light and electron microscopy were utilized to determine any histological changes in periprosthetic tissues. Patient history was gathered from medical records. Two intact and retrieved PEEK rods were used for fatigue testing analysis by sinusoidal load to the spinal construct. RESULTS: All implants showed evidence of plastic deformation around the screw-rod interface, while the inner structure of PEEK rods appeared unchanged with no visible voids or cracks. Examining images captured through light and electron microscopy indicated that phagocytosis of macrophages around PEEK rods was less severe in comparison to the screw-rod interface. The results of an energy spectrum analysis suggested that the distribution of tissue elements around PEEK rods did not differ significantly from normal tissue. During fatigue testing, it was found that the retrieved PEEK rods cracked after 1.36 million tests, whereas the intact PEEK rods completed 5 million fatigue tests without any failure. CONCLUSION: PEEK rods demonstrate satisfactory biocompatibility, corrosion resistance, chemical stability, and mechanical properties. Nevertheless, it is observed that the indentation at the junction between the nut and the rod exhibits relatively weak strength, making it susceptible to breakage. As a precautionary measure, it is recommended to secure the nut with a counter wrench, applying the preset torque to prevent overtightening.


Assuntos
Benzofenonas , Cetonas , Parafusos Pediculares , Polímeros , Humanos , Cetonas/química , Feminino , Masculino , Polietilenoglicóis/química , Pessoa de Meia-Idade , Remoção de Dispositivo , Teste de Materiais , Idoso , Materiais Biocompatíveis , Falha de Prótese , Reoperação
8.
Biosci Rep ; 44(6)2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38836325

RESUMO

Natural and synthetic polymeric materials, particularly soft and hard tissue replacements, are paramount in medicine. We prepared calcium-incorporated sulfonated polyether-ether ketone (SPEEK) polymer membranes for bone applications. The bioactivity was higher after 21 days of immersion in simulated body fluid (SBF) due to calcium concentration in the membrane. We present a new biomaterial healing system composed of calcium and sulfonated polyether ether ketone (Ca-SPEEK) that can function as a successful biomaterial without causing inflammation when tested on bone marrow cells. The Ca-SPEEK exhibited 13 ± 0.5% clot with low fibrin mesh formation compared to 21 ± 0.5% in SPEEK. In addition, the Ca-SPEEK showed higher protein adsorption than SPEEK membranes. As an inflammatory response, IL-1 and TNF-α in the case of Ca-SPEEK were lower than those for SPEEK. We found an early regulation of IL-10 in the case of Ca-SPEEK at 6 h, which may be attributed to the down-regulation of the inflammatory markers IL-1 and TNF-α. These results evidence the innovative bioactivity of Ca-SPEEK with low inflammatory response, opening venues for bone applications.


Assuntos
Materiais Biocompatíveis , Células da Medula Óssea , Cálcio , Polímeros , Fator de Necrose Tumoral alfa , Animais , Camundongos , Células da Medula Óssea/efeitos dos fármacos , Células da Medula Óssea/metabolismo , Polímeros/química , Polímeros/farmacologia , Cálcio/metabolismo , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Fator de Necrose Tumoral alfa/metabolismo , Benzofenonas/química , Benzofenonas/farmacologia , Inflamação/tratamento farmacológico , Polietilenoglicóis/química , Polietilenoglicóis/farmacologia , Cetonas/química , Cetonas/farmacologia , Teste de Materiais , Interleucina-1/metabolismo , Interleucina-10/metabolismo
9.
J Toxicol Environ Health A ; 87(17): 687-700, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38836411

RESUMO

The increasing use of UV filters, such as benzophenone-3 (BP-3) and titanium dioxide nanoparticles (TiO2 NPs), has raised concerns regarding their ecotoxicological effects on the aquatic environment. The aim of the present study was to examine the embryo-larval toxicity attributed to BP-3 or TiO2 NPs, either alone or in a mixture, utilizing zebrafish (Danio rerio) as a model after exposure to environmentally relevant concentrations of these compounds. Zebrafish embryos were exposed to BP-3 (10, 100, or 1000 ng/L) or TiO2 NPs (1000 ng/L) alone or in a mixture (BP-3 10, 100, or 1000 ng/L plus 1000 ng/L of TiO2 NPs) under static conditions for 144 hr. After exposure, BP-3 levels were determined by high-performance liquid chromatography (HPLC). BP-3 levels increased in the presence of TiO2 NPs, indicating that the BP-3 degradation decreased in the presence of the NPs. In addition, in the presence of zebrafish, BP-3 levels in water decreased, indicating that zebrafish embryos and larvae might absorb BP-3. Data demonstrated that, in general, environmentally relevant concentrations of BP-3 and TiO2 NPs, either alone or in a mixture, did not significantly induce changes in heart and spontaneous contractions frequencies, levels of reactive oxygen species (ROS), morphological and morphometric parameters as well as mortality rates during 144 hr exposure. However, the groups exposed to TiO2 NPs alone and in a mixture with BP-3 at 10 ng/L exhibited an earlier significant hatching rate than the controls. Altogether, the data indicates that a potential ecotoxicological impact on the aquatic environment exists.


Assuntos
Benzofenonas , Embrião não Mamífero , Protetores Solares , Titânio , Poluentes Químicos da Água , Peixe-Zebra , Animais , Titânio/toxicidade , Titânio/química , Benzofenonas/toxicidade , Protetores Solares/toxicidade , Protetores Solares/química , Embrião não Mamífero/efeitos dos fármacos , Poluentes Químicos da Água/toxicidade , Nanopartículas/toxicidade , Nanopartículas Metálicas/toxicidade , Ecotoxicologia , Larva/efeitos dos fármacos
10.
J Hazard Mater ; 474: 134841, 2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-38852251

RESUMO

Photochemical transformation is an important attenuation process for the non-steroidal anti-inflammatory drug naproxen (NPX) in both engineered and natural waters. Herein, we investigated the photolysis of NPX in aqueous solution exposed to both ultraviolet (UV, 254 nm) and natural sunlight irradiation. Results show that N2 purging significantly promoted NPX photolysis under UV irradiation, suggesting the formation of excited triplet state (3NPX*) as a critical transient. This inference was supported by benzophenone photosensitization and transient absorption spectra. Sunlight quantum yield of NPX was only one fourteenth of that under UV irradiation, suggesting the wavelength-dependence of NPX photochemistry. 3NPX* formed upon irradiation of NPX underwent photodecarboxylation leading to the formation of 2-(1-hydroxyethyl)-6-methoxynaphthalene (2HE6MN), 2-(1-hydroperoxyethyl)-6-methoxynaphthalene (2HPE6MN), and 2-acetyl-6-methoxynaphthalene (2A6MN). Notably, the conjugation and spin-orbit coupling effects of carbonyl make 2A6MN a potent triplet sensitizer, therefore promoting the photodegradation of the parent NPX. In hospital wastewater, the photolysis of NPX was influenced because the photoproduct 2A6MN and wastewater components could competitively absorb photons. Bioluminescence inhibition assay demonstrated that photoproducts of NPX exhibited higher toxicity than the parent compound. Results of this study provide new insights into the photochemical behaviors of NPX during UV treatment and in sunlit surface waters.


Assuntos
Anti-Inflamatórios não Esteroides , Naproxeno , Fotólise , Luz Solar , Raios Ultravioleta , Poluentes Químicos da Água , Naproxeno/química , Naproxeno/efeitos da radiação , Poluentes Químicos da Água/química , Poluentes Químicos da Água/efeitos da radiação , Poluentes Químicos da Água/toxicidade , Anti-Inflamatórios não Esteroides/química , Anti-Inflamatórios não Esteroides/efeitos da radiação , Benzofenonas/química , Benzofenonas/efeitos da radiação , Fármacos Fotossensibilizantes/química , Fármacos Fotossensibilizantes/efeitos da radiação
11.
Planta Med ; 90(7-08): 631-640, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38843801

RESUMO

Many polyprenylated acylphloroglucinols with fascinating chemical structures and intriguing biological activities have been identified as key to phytochemicals isolated from Garcinia, Hypericum, and related genera. In the present work, two chiral, tautomeric, highly-oxygenated polyprenylated acylphloroglucinols tethered with acyl and prenyl moieties on a bicyclo[3.3.1]nonanetrione core were isolated from the 95% ethanolic extract of Garcinia gummi-gutta fruit. The structures of both compounds were elucidated based on the NMR and MS data with ambiguity in the exact position of the enol and keto functions at C-1 and C-3 of the core structure. The structures of both polyprenylated acylphloroglucinols were established as a structurally revised guttiferone J and the new iso-guttiferone J with the aid of gauge-independent atomic orbital NMR calculations, CP3 probability analyses, specific rotation calculations, and electronic circular dichroism calculations in combination with the experimental data. The structures of both compounds resemble hyperforin, a potent activator of the human pregnane X receptor. As expected, both compounds showed strong pregnane X receptor activation at 10 µM [7.1-fold (guttiferone J) and 5.0-fold (iso-guttiferone J)], explained by a molecular docking study, necessitating further in-depth investigation to substantiate the herb-drug interaction potential of G. gummi-gutta upon co-administration with pharmaceutical drugs.


Assuntos
Garcinia , Espectroscopia de Ressonância Magnética , Garcinia/química , Estrutura Molecular , Frutas/química , Benzofenonas/química , Benzofenonas/isolamento & purificação , Benzofenonas/farmacologia , Extratos Vegetais/química , Extratos Vegetais/farmacologia , Compostos Fitoquímicos/isolamento & purificação , Compostos Fitoquímicos/química , Compostos Fitoquímicos/farmacologia , Floroglucinol/química , Floroglucinol/isolamento & purificação , Humanos
12.
Environ Monit Assess ; 196(7): 599, 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38844615

RESUMO

This research was carried out in order to assess a baseline occurrence in Biscayne National Park, Florida, of four organic contaminants: the UV filters oxybenzone, dioxybenzone, and benzophenone, as well as the topical pain reliever benzocaine. A total of 35 samples were taken from five locations within the park, four near barrier islands, and one at a coral reef. Analyses were carried out using liquid chromatography coupled to high-resolution mass spectrometry. Oxybenzone was detected in 26% of samples from the park at concentrations up to 31 ng/L. Benzophenone was detected in 49% of samples from the park at concentrations up to 131 ng/L. Benzocaine and dioxybenzone were not detected in any of the samples.


Assuntos
Benzofenonas , Monitoramento Ambiental , Parques Recreativos , Protetores Solares , Poluentes Químicos da Água , Florida , Benzofenonas/análise , Poluentes Químicos da Água/análise , Protetores Solares/análise , Benzocaína/análise
13.
Skin Res Technol ; 30(5): e13744, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38771547

RESUMO

BACKGROUND: Evidence from animal models suggests a role for the organic ultraviolet filter benzophenone-3's (BP-3) on white blood cells (WBCs). However, BP-3's effect on WBCs in humans is unknown. MATERIALS AND METHODS: We used National Health and Nutrition Examination Survey data from 2003 to 2016. We included participants >6 years with data on urinary BP-3, urinary creatinine, and WBC count. Quintiles of urinary creatinine-normalized BP-3 (CnBP-3) levels were used in linear regression models adjusting for age, gender, race, body mass index (BMI), smoking status, education level, family income to poverty threshold ratio, survey cycle, and season. RESULTS: Of the 16 959 participants, 8564 (50.5%) were females, 6602 (38.9%) were White, and 3870 (22.8%) were Black. The mean (standard deviation) age was 37.6 (22.7) years, BMI was 26.8 (7.40) kg/m2, WBC count was 7.22 (2.53) × 109/L, neutrophil count was 4.15 (1.86) × 109/L, and lymphocyte count was 2.25 (1.33) × 109/L and median (interquartile range) of CnBP-3 was 12.1 (44.9) µg/gm. The highest quintile of CnBP-3 was associated with significantly lower WBC and neutrophil counts compared to the lowest quintile of CnBP-3 (Δ quintiles = -137 × 106/L, 95% CI: -249 to -24, p = 0.02 and = -177 × 106/L, 95% CI: -323 to -30, p = 0.02, respectively). In contrast, we did not observe a difference in lymphocyte count between the lowest and highest quintiles of CnBP-3 in unadjusted or adjusted analyses. CONCLUSION: We found an inverse relationship between BP-3 levels and WBC and neutrophil counts, and not with lymphocyte count. Further research is needed to confirm our findings.


Assuntos
Benzofenonas , Inquéritos Nutricionais , Protetores Solares , Humanos , Feminino , Masculino , Contagem de Leucócitos , Adulto , Pessoa de Meia-Idade , Adulto Jovem , Creatinina/sangue , Creatinina/urina , Adolescente
14.
BMC Surg ; 24(1): 169, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38811965

RESUMO

BACKGROUND: Whether polyetheretherketone (PEEK) rods have potential as an alternative to titanium alloy (Ti) rods in transforaminal lumbar interbody fusion (TLIF) remains unclear, especially in cases with insufficient anterior support due to the absence of a cage. The purpose of this study was to investigate biomechanical differences between PEEK rods and Ti rods in TLIF with and without a cage. METHODS: An intact L1-L5 lumbar finite element model was constructed and validated. Accordingly, four TLIF models were developed: (1) Ti rods with a cage; (2) PEEK rods with a cage; (3) Ti rods without a cage; and (4) PEEK rods without a cage. The biomechanical properties were then compared among the four TLIF constructs. RESULTS: With or without a cage, no obvious differences were found in the effect of PEEK rods and Ti rods on the range of motion, adjacent disc stress, and adjacent facet joint force. Compared to Ti rods, PEEK rods increase the average bone graft strain (270.8-6055.2 µE vs. 319.0-8751.6 µE). Moreover, PEEK rods reduced the stresses on the screw-rod system (23.1-96.0 MPa vs. 7.2-48.4 MPa) but increased the stresses on the cage (4.6-35.2 MPa vs. 5.6-40.9 MPa) and endplates (5.7-32.5 MPa vs. 6.6-37.6 MPa). CONCLUSIONS: Regardless of whether a cage was used for TLIF, PEEK rods theoretically have the potential to serve as an alternative to Ti rods because they may provide certain stability, increase the bone graft strain, and reduce the posterior instrumentation stress, which might promote bony fusion and decrease instrumentation failure.


Assuntos
Ligas , Benzofenonas , Análise de Elementos Finitos , Cetonas , Vértebras Lombares , Polietilenoglicóis , Polímeros , Fusão Vertebral , Titânio , Humanos , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Fenômenos Biomecânicos , Vértebras Lombares/cirurgia , Amplitude de Movimento Articular , Materiais Biocompatíveis
15.
Sci Rep ; 14(1): 12186, 2024 05 28.
Artigo em Inglês | MEDLINE | ID: mdl-38806564

RESUMO

Polyetheretherketone (PEEK) is considered as an excellent biomaterial for bone grafting and connective tissue replacement. The clinical potential is, however, limited by its bioinertness, poor osteoconduction, and weak antibacterial activity. These disadvantages can be overcome by introducing suitable additives to produce mineral-polymer composites or coatings. In this work, a PEEK-based bioactive composite has been obtained by blending the polymer with magnesium phosphate (Mg3(PO4)2) particles in amounts ranging from 1 to 10 wt.% using the hot press technique. The obtained composite exhibited improved mechanical and physical properties, above the lower limits set for bone engineering applications. The tested grafts were found to not induce cytotoxicity. The presence of magnesium phosphate induced the mineralisation process with no adverse effects on the expression of the marker crucial for osteoblastic differentiation. The most promising results were observed in the grafts containing 1 wt.% of magnesium phosphate embedded within the PEEK matrix. The improved bioactivity of grafts, together with suitable physical-chemical and mechanical properties, indicate this composite as a promising orthopaedic implant material.


Assuntos
Benzofenonas , Materiais Biocompatíveis , Cetonas , Fosfatos , Polietilenoglicóis , Polímeros , Cetonas/química , Cetonas/farmacologia , Polímeros/química , Polietilenoglicóis/química , Materiais Biocompatíveis/química , Fosfatos/química , Humanos , Compostos de Magnésio/química , Compostos de Magnésio/farmacologia , Teste de Materiais , Osteoblastos/efeitos dos fármacos , Osteoblastos/metabolismo
16.
Clin Oral Investig ; 28(6): 336, 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38795258

RESUMO

OBJECTIVE: Stress distribution assessment by finite elements analysis in poly(etheretherketone) (PEEK) implant and abutment as retainers of single crowns in the anterior region. MATERIALS AND METHODS: Five 3D models were created, varying implant/abutment manufacturing materials: titanium (Ti), zirconia (Zr), pure PEEK (PEEKp), carbon fiber-reinforced PEEK (PEEKc), glass fiber-reinforced PEEK (PEEKg). A 50 N load was applied 30o off-axis at the incisal edge of the upper central incisor. The Von Mises stress (σvM) was evaluated on abutment, implant/screw, and minimum principal stress (σmin) and maximum shear stress (τmax) for cortical and cancellous bone. RESULTS: The abutment σvM lowest stress was observed in PEEKp group, being 70% lower than Ti and 74% than Zr. On the implant, PEEKp reduced 68% compared to Ti and a 71% to Zr. In the abutment screws, an increase of at least 33% was found in PEEKc compared to Ti, and of at least 81% to Zr. For cortical bone, the highest τmax values were in the PEEKp group, and a slight increase in stress was observed compared to all PEEK groups with Ti and Zr. For σmin, the highest stress was found in the PEEKc. Stress increased at least 7% in cancellous bone for all PEEK groups. CONCLUSION: Abutments and implants made by PEEKc concentrate less σvM stress, transmitting greater stress to the cortical and medullary bone. CLINICAL RELEVANCE: The best stress distribution in PEEKc components may contribute to decreased stress shielding; in vitro and in vivo research is recommended to investigate this.


Assuntos
Benzofenonas , Coroas , Dente Suporte , Análise do Estresse Dentário , Análise de Elementos Finitos , Cetonas , Teste de Materiais , Polietilenoglicóis , Polímeros , Titânio , Zircônio , Cetonas/química , Polietilenoglicóis/química , Humanos , Zircônio/química , Titânio/química , Fibra de Carbono/química , Projeto do Implante Dentário-Pivô , Incisivo , Materiais Dentários/química , Implantes Dentários para Um Único Dente , Osso Cortical , Vidro/química , Planejamento de Prótese Dentária
17.
Langmuir ; 40(20): 10648-10662, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38712915

RESUMO

This study presents new insights into the potential role of polyelectrolyte interfaces in regulating low friction and interstitial fluid pressurization of cartilage. Polymer brushes composed of hydrophilic 3-sulfopropyl methacrylate potassium salt (SPMK) tethered to a PEEK substrate (SPMK-g-PEEK) are a compelling biomimetic solution for interfacing with cartilage, inspired by the natural lubricating biopolyelectrolyte constituents of synovial fluid. These SPMK-g-PEEK surfaces exhibit a hydrated compliant layer approximately 5 µm thick, demonstrating the ability to maintain low friction coefficients (µ ∼ 0.01) across a wide speed range (0.1-200 mm/s) under physiological loads (0.75-1.2 MPa). A novel polyelectrolyte-enhanced tribological rehydration mechanism is elucidated, capable of recovering up to ∼12% cartilage strain and subsequently facilitating cartilage interstitial fluid recovery, under loads ranging from 0.25 to 2.21 MPa. This is attributed to the combined effects of fluid confinement within the contact gap and the enhanced elastohydrodynamic behavior of polymer brushes. Contrary to conventional theories that emphasize interstitial fluid pressurization in regulating cartilage lubrication, this work demonstrates that SPMK-g-PEEK's frictional behavior with cartilage is independent of these factors and provides unabating aqueous lubrication. Polyelectrolyte-enhanced tribological rehydration can occur within a static contact area and operates independently of known mechanisms of cartilage interstitial fluid recovery established for converging or migrating cartilage contacts. These findings challenge existing paradigms, proposing a novel polyelectrolyte-cartilage tribological mechanism not exclusively reliant on interstitial fluid pressurization or cartilage contact geometry. The implications of this research extend to a broader understanding of synovial joint lubrication, offering insights into the development of joint replacement materials that more accurately replicate the natural functionality of cartilage.


Assuntos
Lubrificação , Polímeros , Polímeros/química , Animais , Polieletrólitos/química , Polietilenoglicóis/química , Cartilagem/química , Cartilagem/efeitos dos fármacos , Propriedades de Superfície , Benzofenonas/química , Cartilagem Articular/química , Cartilagem Articular/fisiologia , Cetonas/química
18.
Ecotoxicol Environ Saf ; 278: 116441, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38733805

RESUMO

Oxybenzone (OBZ; benzophenone-3, CAS# 131-57-7), as a new pollutant and ultraviolet absorbent, shows a significant threat to the survival of phytoplankton. This study aims to explore the acute toxic effects of OBZ on the growth of the microalga Selenastrum capricornutum, as well as the mechanisms for its damage to the primary metabolic pathways of photosynthesis and respiration. The results demonstrated that the concentrations for 50 % of maximal effect (EC50) of OBZ for S. capricornutum were 9.07 mg L-1 and 8.54 mg L-1 at 72 h and 96 h, respectively. A dosage of 4.56 mg L-1 OBZ significantly lowered the photosynthetic oxygen evolution rate of S. capricornutum in both light and dark conditions for a duration of 2 h, while it had no effect on the respiratory oxygen consumption rate under darkness. OBZ caused a significant decline in the efficiency of photosynthetic electron transport due to its damage to photosystem II (PSII), thereby decreasing the photosynthetic oxygen evolution rate. Over-accumulated H2O2 was produced under light due to the damage caused by OBZ to the donor and acceptor sides of PSII, resulting in increased peroxidation of cytomembranes and inhibition of algal respiration. OBZ's damage to photosynthesis and respiration will hinder the conversion and reuse of energy in algal cells, which is an important reason that OBZ has toxic effects on S. capricornutum. The present study indicated that OBZ has an acute toxic effect on the microalga S. capricornutum. In the two most important primary metabolic pathways in algae, photosynthesis is more sensitive to the toxicity of OBZ than respiration, especially in the dark.


Assuntos
Benzofenonas , Microalgas , Fotossíntese , Protetores Solares , Fotossíntese/efeitos dos fármacos , Benzofenonas/toxicidade , Microalgas/efeitos dos fármacos , Protetores Solares/toxicidade , Poluentes Químicos da Água/toxicidade , Peróxido de Hidrogênio/metabolismo , Complexo de Proteína do Fotossistema II/metabolismo , Complexo de Proteína do Fotossistema II/efeitos dos fármacos , Raios Ultravioleta , Transporte de Elétrons/efeitos dos fármacos
19.
Chemosphere ; 358: 142238, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38705413

RESUMO

Predicting the metabolic activation mechanism and potential hazardous metabolites of environmental endocrine-disruptors is a challenging and significant task in risk assessment. Here the metabolic activation mechanism of benzophenone-3 catalyzed by P450 1A1 was investigated by using Molecular Dynamics, Quantum Mechanics/Molecular Mechanics and Density Functional Theory approaches. Two elementary reactions involved in the metabolic activation of BP-3 with P450 1A1: electrophilic addition and hydrogen abstraction reactions were both discussed. Further conversion reactions of epoxidation products, ketone products and the formaldehyde formation reaction were investigated in the non-enzymatic environment based on previous experimental reports. Binding affinities analysis of benzophenone-3 and its metabolites to sex hormone binding globulin indirectly demonstrates that they all exhibit endocrine-disrupting property. Toxic analysis shows that the eco-toxicity and bioaccumulation values of the benzophenone-3 metabolites are much lower than those of benzophenone-3. However, the metabolites are found to have skin-sensitization effects. The present study provides a deep insight into the biotransformation process of benzophenone-3 catalyzed by P450 1A1 and alerts us to pay attention to the adverse effects of benzophenone-3 and its metabolites in human livers.


Assuntos
Benzofenonas , Citocromo P-450 CYP1A1 , Disruptores Endócrinos , Benzofenonas/metabolismo , Disruptores Endócrinos/metabolismo , Citocromo P-450 CYP1A1/metabolismo , Teoria Quântica , Humanos , Simulação de Dinâmica Molecular , Catálise , Biotransformação
20.
BMC Oral Health ; 24(1): 545, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38730391

RESUMO

BACKGROUND: This Finite Element Analysis was conducted to analyze the biomechanical behaviors of titanium base abutments and several crown materials with respect to fatigue lifetime and stress distribution in implants and prosthetic components. METHODS: Five distinct designs of implant-supported single crowns were modeled, including a polyetheretherketone (PEEK), polymer-infiltrated ceramic network, monolithic lithium disilicate, and precrystallized and crystallized zirconia-reinforced lithium silicates supported by a titanium base abutment. For the static load, a 100 N oblique load was applied to the buccal incline of the palatal cusp of the maxillary right first premolar. The dynamic load was applied in the same way as in static loading with a frequency of 1 Hz. The principal stresses in the peripheral bone as well as the von Mises stresses and fatigue strength of the implants, abutments, prosthetic screws, and crowns were assessed. RESULTS: All of the models had comparable von Mises stress values from the implants and abutments, as well as comparable maximum and minimum principal stress values from the cortical and trabecular bones. The PEEK crown showed the lowest stress (46.89 MPa) in the cervical region. The prosthetic screws and implants exhibited the highest von Mises stress among the models. The lithium disilicate crown model had approximately 9.5 times more cycles to fatique values for implants and 1.7 times more cycles to fatique values for abutments than for the lowest ones. CONCLUSIONS: With the promise of at least ten years of clinical success and favorable stress distributions in implants and prosthetic components, clinicians can suggest using an implant-supported lithium disilicate crown with a titanium base abutment.


Assuntos
Benzofenonas , Coroas , Dente Suporte , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Análise de Elementos Finitos , Titânio , Titânio/química , Humanos , Porcelana Dentária/química , Polietilenoglicóis/química , Materiais Dentários/química , Polímeros , Cetonas/química , Zircônio/química , Implantes Dentários para Um Único Dente , Teste de Materiais , Projeto do Implante Dentário-Pivô , Fenômenos Biomecânicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...