Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21.526
Filtrar
1.
PLoS One ; 19(6): e0296913, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38870173

RESUMO

Surgical oncology often requires the use of contrast-enhanced cross-sectional imaging preoperatively to characterize solitary tumours and identify sentinel lymph nodes. Intraoperative optical guidance can effectively aid tissue-sparing tumour excision and locate sentinel lymph nodes. Nanotrast-CF800 (CF800) is a novel dual-modality contrast agent, which co-encapsulates iohexol and indocyanine green (ICG) within a liposomal nanoparticle. It was developed for preoperative and intraoperative imaging of solitary tumours and sentinel lymph node mapping and its efficacy has been demonstrated in preclinical animal models (Zheng et al. 2015). The objective of this study is to evaluate the safety profile of CF800 following intravenous administration in healthy dogs. Six research dogs were randomized into two groups. Group 1 received a low dose (1 mL/kg) and group 2 received a high dose (5 mL/kg). Dogs were placed under general anesthesia and a continuous rate infusion of CF800 was administered based on group allocation. Physiologic parameters including heart rate, respiratory rate, direct arterial blood pressure, cardiac output, and temperature were measured at set time points. Plasma concentrations of iohexol, ICG, and histamine were measured at set time points. Dogs underwent whole body computed tomography scans pre-injection, 2-, and 7-days post-injection (p.i.). Contrast enhancement was measured in select organ systems and great vessels at each time point. There were no significant changes in physiologic parameters following IV infusion of CF800 in all dogs. Plasma iohexol and ICG concentrations peaked at 1 day p.i., while histamine concentrations peaked at 30 minutes p.i. Significant contrast enhancement was noted within the liver, heart, aorta, and caudal vena cava on day 2 p.i., which was significantly different compared to baseline. Prolonged contrast retention within the liver was identified. Intravenous administration of CF800 was safe to use in healthy dogs with no significant systemic adverse effects.


Assuntos
Meios de Contraste , Verde de Indocianina , Iohexol , Nanopartículas , Neoplasias , Animais , Cães , Nanopartículas/química , Meios de Contraste/administração & dosagem , Iohexol/administração & dosagem , Verde de Indocianina/química , Verde de Indocianina/administração & dosagem , Neoplasias/cirurgia , Neoplasias/diagnóstico por imagem , Cirurgia Assistida por Computador/métodos , Feminino , Masculino
3.
Clin Orthop Surg ; 16(3): 430-440, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38827763

RESUMO

Background: Computer-assisted navigation surgery (CAS) during primary total knee arthroplasty (TKA) may help improve outcomes for patients with extra-articular deformity (EAD); however, this has not been extensively studied. Therefore, we aimed to investigate the clinical and radiological outcomes following primary TKA using CAS in patients with EAD. Methods: We searched Medline, Embase, and the Cochrane Library up to March 3, 2023 for studies investigating surgical outcomes of using the navigation system for TKA to treat patients with EAD. From 14 studies, 539 knees with EAD that underwent navigation TKA were enrolled. We investigated the knee range of motion (ROM), outcome scores at final follow-up (Knee Society Score [KSS] and Knee Functional Score [KFS]), and pre- and postoperative mechanical hip-knee-ankle (mHKA) angle using lower extremity scanogram. The meta-analysis was based on the single-arm method, and all data were pooled using a random-effects model. Results: Following our meta-analyses, the mean knee ROM changed from 87.0° (95% confidence interval [CI], 75.9°-98.1°) preoperatively to 109.4° (95% CI, 97.9°-120.8°) postoperatively. The adjusted KSS was 93.45 points (95% CI, 88.36-98.54 points), and the adjusted KFS was 91.57 points (95% CI, 86.80-96.33 points) in knees with EAD that underwent CAS-TKA. As a radiological outcome, the mHKA angle changed from 169.53° (95% CI, 166.90°-172.16°) preoperatively to 178.81° (95% CI, 178.31°-179.30°) postoperatively. Conclusions: CAS-TKA yielded positive clinical results and demonstrated a satisfactory alignment of the lower limb's mechanical axis. CAS-TKA showed promise for primary TKA procedures, demonstrating favorable clinical and radiological outcomes even in complex cases involving EAD.


Assuntos
Artroplastia do Joelho , Amplitude de Movimento Articular , Cirurgia Assistida por Computador , Humanos , Artroplastia do Joelho/métodos , Cirurgia Assistida por Computador/métodos , Articulação do Joelho/cirurgia , Articulação do Joelho/diagnóstico por imagem
4.
Bull Math Biol ; 86(7): 83, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38842602

RESUMO

5-Aminolevulinic Acid (5-ALA) is the only fluorophore approved by the FDA as an intraoperative optical imaging agent for fluorescence-guided surgery in patients with glioblastoma. The dosing regimen is based on rodent tests where a maximum signal occurs around 6 h after drug administration. Here, we construct a computational framework to simulate the transport of 5-ALA through the stomach, blood, and brain, and the subsequent conversion to the fluorescent agent protoporphyrin IX at the tumor site. The framework combines compartmental models with spatially-resolved partial differential equations, enabling one to address questions regarding quantity and timing of 5-ALA administration before surgery. Numerical tests in two spatial dimensions indicate that, for tumors exceeding the detection threshold, the time to peak fluorescent concentration is 2-7 h, broadly consistent with the current surgical guidelines. Moreover, the framework enables one to examine the specific effects of tumor size and location on the required dose and timing of 5-ALA administration before glioblastoma surgery.


Assuntos
Ácido Aminolevulínico , Neoplasias Encefálicas , Simulação por Computador , Glioblastoma , Conceitos Matemáticos , Modelos Biológicos , Protoporfirinas , Cirurgia Assistida por Computador , Glioblastoma/cirurgia , Glioblastoma/tratamento farmacológico , Glioblastoma/patologia , Glioblastoma/diagnóstico por imagem , Ácido Aminolevulínico/administração & dosagem , Humanos , Neoplasias Encefálicas/cirurgia , Protoporfirinas/administração & dosagem , Protoporfirinas/metabolismo , Cirurgia Assistida por Computador/métodos , Animais , Fármacos Fotossensibilizantes/administração & dosagem , Imagem Óptica/métodos , Corantes Fluorescentes/administração & dosagem
5.
PLoS One ; 19(6): e0304843, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38838047

RESUMO

Imaging modalities for percutaneous coronary intervention (PCI), such as intravascular ultrasound (IVUS) or optical coherence tomography (OCT), have increased in the current PCI era. However, their clinical benefits in acute myocardial infarction (AMI) have not been fully elucidated. This study investigated the long-term outcomes of image-guided PCI in patients with AMI using data from the Korean Acute Myocardial Infarction Registry. A total of 9,271 patients with AMI, who underwent PCI with second-generation drug-eluting stents between November 2011 and December 2015, were retrospectively examined, and target lesion failure (TLF) at 3 years (defined as the composite of cardiac death, target vessel myocardial infarction, and ischemia-driven target lesion revascularization) was evaluated. From the registry, 2,134 patients (23.0%) underwent image-guided PCI (IVUS-guided: n = 1,919 [20.6%]; OCT-guided: n = 215 patients [2.3%]). Based on propensity score matching, image-guided PCI was associated with a significant reduction in TLF (hazard ratio: 0.76; 95% confidence interval: 0.59-0.98, p = 0.035). In addition, the TLF incidence in the OCT-guided PCI group was comparable to that in the IVUS-guided PCI group (5.3% vs 4.7%, p = 0.903). Image-guided PCI, including IVUS and OCT, is associated with favorable clinical outcomes in patients with AMI at 3 years post-intervention. Additionally, OCT-guided PCI is not inferior to IVUS-guided PCI in patients with AMI.


Assuntos
Infarto do Miocárdio , Intervenção Coronária Percutânea , Sistema de Registros , Tomografia de Coerência Óptica , Humanos , Intervenção Coronária Percutânea/métodos , Masculino , Feminino , República da Coreia/epidemiologia , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/terapia , Infarto do Miocárdio/cirurgia , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Tomografia de Coerência Óptica/métodos , Estudos Retrospectivos , Ultrassonografia de Intervenção/métodos , Stents Farmacológicos , Cirurgia Assistida por Computador/métodos
6.
BMC Cancer ; 24(1): 697, 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38844894

RESUMO

BACKGROUND: Fluorescence-guided precision cancer surgery may improve survival and minimize patient morbidity. Efficient development of promising interventions is however hindered by a lack of common methodology. This methodology review aimed to synthesize descriptions of technique, governance processes, surgical learning and outcome reporting in studies of fluorescence-guided cancer surgery to provide guidance for the harmonized design of future studies. METHODS: A systematic search of MEDLINE, EMBASE and CENTRAL databases from 2016-2020 identified studies of all designs describing the use of fluorescence in cancer surgery. Dual screening and data extraction was conducted by two independent teams. RESULTS: Of 13,108 screened articles, 426 full text articles were included. The number of publications per year increased from 66 in 2016 to 115 in 2020. Indocyanine green was the most commonly used fluorescence agent (391, 91.8%). The most common reported purpose of fluorescence guided surgery was for lymph node mapping (195, 5%) and non-specific tumour visualization (94, 2%). Reporting about surgical learning and governance processes incomplete. A total of 2,577 verbatim outcomes were identified, with the commonly reported outcome lymph node detection (796, 30%). Measures of recurrence (32, 1.2%), change in operative plan (23, 0.9%), health economics (2, 0.1%), learning curve (2, 0.1%) and quality of life (2, 0.1%) were rarely reported. CONCLUSION: There was evidence of methodological heterogeneity that may hinder efficient evaluation of fluorescence surgery. Harmonization of the design of future studies may streamline innovation.


Assuntos
Neoplasias , Cirurgia Assistida por Computador , Humanos , Neoplasias/cirurgia , Cirurgia Assistida por Computador/métodos , Fluorescência , Verde de Indocianina , Imagem Óptica/métodos
7.
BMC Surg ; 24(1): 181, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38867212

RESUMO

BACKGROUND: Hepatectomy stands as a curative management for liver cancer. The critical factor for minimizing recurrence rate and enhancing overall survival of liver malignancy is to attain a negative margin hepatic resection. Recently, Indocyanine green (ICG) fluorescence imaging has been proven implemental in aiding laparoscopic liver resection, enabling real-time tumor identification and precise liver segmentation. The purpose of this study is to conduct a systematic review and meta-analysis to ascertain whether ICG-guided laparoscopic hepatectomy yields a higher incidence of complete tumor eradication (R0) resections. METHODS: The search encompassed databases such as PubMed, Cochrane Library database, Scopus, ScienceDirect, and Ovid in April 2024, in strict adherence to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Studies involving patients with malignant liver lesions who underwent ICG-guided laparoscopic hepatectomy and reported R0 resection outcomes were eligible for inclusion in this review. RESULTS: In a total of seven studies, involving 598 patients, were included in the meta-analysis. The ICG demonstrated a significantly elevated R0 resection rate compared to the non-ICG group [98.6% (359/364) vs. 93.1% (339/364), odds ratio (OR) = 3.76, 95% confidence intervals (CI) 1.45-9.51, P = 0.005]. Notably, no heterogeneity was observed (I2 = 0%, P = 0.5). However, the subtype analysis focusing on hepatocellular carcinoma [98.2% (165/168) vs. 93.6% (161/172), OR = 3.34, 95% CI 0.94-11.91, P = 0.06) and the evaluation of margin distance (4.96 ± 2.41 vs. 2.79 ± 1.92 millimeters, weighted mean difference = 1.26, 95% CI -1.8-4.32, P = 0.42) revealed no apparent differences. Additionally, the incidence of overall postoperative complications was comparable between both groups, 27.6% (66/239) in the ICG group and 25.4% (75/295) in the non-ICG group (OR = 0.96, 95% CI 0.53-1.76, P = 0.9). No disparities were identified in operative time, intraoperative blood loss, postoperative blood transfusion, and length of hospital stay after the surgery. CONCLUSIONS: The implementation of ICG-guided laparoscopic hepatectomy can be undertaken with confidence, as it does not compromise either intraoperative or postoperative events. Furthermore, the ICG-guided approach is beneficial to achieving a complete eradication of the tumor during hepatic resection. TRIAL REGISTRATION: PROSPERO registration number CRD42023446440.


Assuntos
Hepatectomia , Verde de Indocianina , Laparoscopia , Neoplasias Hepáticas , Margens de Excisão , Humanos , Hepatectomia/métodos , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/patologia , Laparoscopia/métodos , Cirurgia Assistida por Computador/métodos , Imagem Óptica/métodos
8.
Nan Fang Yi Ke Da Xue Xue Bao ; 44(5): 967-973, 2024 May 20.
Artigo em Chinês | MEDLINE | ID: mdl-38862455

RESUMO

OBJECTIVE: To develop the'E-Bone', a comprehensive one-stop preoperative planning system for reverse total shoulder arthroplasty with improved accuracy and efficiency. METHODS: The nnU-net deep neural network was utilized for scapula segmentation to obtain precise scapula segmentation results. Based on the 3 key factors, namely bone density, upward and downward angle and nail length, the base was automatically positioned. The quantitative parameters required for surgical planning were calculated. A personalized guide plate was generated by combining glenoid morphology and base positioning information. The system interface was developed to modularize various functions for easy use, providing interactive operation and real-time display. RESULTS: Compared with the Mimics system, the'E-bone'preoperative planning system reduced complex manual adjustments during the planning process. The average planned nail length was longer than that of the Mimics system, and the planning time was reduced by 86%. The scapula segmentation accuracy of this system reached 99.93%, better than that of Mimics to achieve a higher precision. CONCLUSION: The"E-bone"system provides a one-stop, efficient, and accurate preoperative planning system for reverse shoulder replacement and potentially broader clinical applications.


Assuntos
Artroplastia do Ombro , Humanos , Artroplastia do Ombro/métodos , Redes Neurais de Computação , Escápula/cirurgia , Cirurgia Assistida por Computador/métodos
9.
Int J Med Robot ; 20(3): e2639, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38847191

RESUMO

BACKGROUND: For the fracture reduction robot, the position tracking accuracy and compliance are affected by dynamic loads from muscle stretching, uncertainties in robot dynamics models, and various internal and external disturbances. METHODS: A control method that integrates a Radial Basis Function Neural Network (RBFNN) with Nonlinear Disturbance Observer is proposed to enhance position tracking accuracy. Additionally, an admittance control is employed for force tracking to enhance the robot's compliance, thereby improving the safety. RESULTS: Experiments are conducted on a long bone fracture model with simulated muscle forces and the results demonstrate that the position tracking error is less than ±0.2 mm, the angular displacement error is less than ±0.3°, and the maximum force tracking error is 26.28 N. This result can meet surgery requirements. CONCLUSIONS: The control method shows promising outcomes in enhancing the safety and accuracy of long bone fracture reduction with robotic assistance.


Assuntos
Algoritmos , Fraturas Ósseas , Redes Neurais de Computação , Dinâmica não Linear , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Fraturas Ósseas/cirurgia , Simulação por Computador , Fenômenos Biomecânicos , Desenho de Equipamento , Robótica , Reprodutibilidade dos Testes , Cirurgia Assistida por Computador/métodos
10.
Int J Med Robot ; 20(3): e2649, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38847242

RESUMO

BACKGROUND: Endoscope retrograde cholangiopancreatography is a standard surgical treatment for gallbladder and pancreatic diseases. However, surgeons is at high risk and require sufficient surgical experience and skills. METHODS: (1) The simultaneous localisation and mapping technique to reconstruct the surgical environment. (2) The preoperative 3D model is transformed into the intraoperative video environment to implement the multi-modal fusion. (3) A framework for virtual-to-real projection based on hand-eye alignment. For the purpose of projecting the 3D model onto the imaging plane of the camera, it uses position data from electromagnetic sensors. RESULTS: Our AR-assisted navigation system can accurately guide physicians, which means a distance of registration error to be restricted to under 5 mm and a projection error of 5.76 ± 2.13, and the intubation procedure is done at 30 frames per second. CONCLUSIONS: Coupled with clinical validation and user studies, both the quantitative and qualitative results indicate that our navigation system has the potential to be highly useful in clinical practice.


Assuntos
Realidade Aumentada , Colangiopancreatografia Retrógrada Endoscópica , Imagens de Fantasmas , Cirurgia Assistida por Computador , Humanos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/instrumentação , Imageamento Tridimensional/métodos , Sistemas de Navegação Cirúrgica , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Reprodutibilidade dos Testes
11.
J Vis Exp ; (207)2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38856206

RESUMO

This protocol helps assess the accuracy and workflow of an augmented reality (AR) hybrid navigation system using the Magic Leap head-mounted display (HMD) for minimally invasive pedicle screw placement. The cadaveric porcine specimens were placed on a surgical table and draped with sterile covers. The levels of interest were identified using fluoroscopy, and a dynamic reference frame was attached to the spinous process of a vertebra in the region of interest. Cone beam computerized tomography (CBCT) was performed, and a 3D rendering was automatically generated, which was used for the subsequent planning of the pedicle screw placements. Each surgeon was fitted with an HMD that was individually eye-calibrated and connected to the spinal navigation system. Navigated instruments, tracked by the navigation system and displayed in 2D and 3D in the HMD, were used for 33 pedicle cannulations, each with a diameter of 4.5 mm. Postprocedural CBCT scans were assessed by an independent reviewer to measure the technical (deviation from the planned path) and clinical (Gertzbein grade) accuracy of each cannulation. The navigation time for each cannulation was measured. The technical accuracy was 1.0 mm ± 0.5 mm at the entry point and 0.8 mm ± 0.1 mm at the target. The angular deviation was 1.5° ± 0.6°, and the mean insertion time per cannulation was 141 s ± 71 s. The clinical accuracy was 100% according to the Gertzbein grading scale (32 grade 0; 1 grade 1). When used for minimally invasive pedicle cannulations in a porcine model, submillimeter technical accuracy and 100% clinical accuracy could be achieved with this protocol.


Assuntos
Realidade Aumentada , Parafusos Pediculares , Animais , Suínos , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Modelos Animais
13.
Int J Med Robot ; 20(3): e2638, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38821869

RESUMO

BACKGROUND: This paper proposes a haptic guidance system to improve catheter navigation within a simulated environment. METHODS: Three force profiles were constructed to evaluate the system: collision prevention; centreline navigation; and a novel force profile of reinforcement learning (RL). All force profiles were evaluated from the left common iliac to the right atrium. RESULTS: Our findings show that providing haptic feedback improved surgical safety compared to visual-only feedback. If staying inside the vasculature is the priority, RL provides the safest option. It is also shown that the performance of each force profile varies in different anatomical regions. CONCLUSION: The implications of these findings are significant, as they hold the potential to improve how and when haptic feedback is applied for cardiovascular intervention.


Assuntos
Cirurgia Assistida por Computador , Humanos , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/instrumentação , Simulação por Computador , Retroalimentação , Catéteres , Desenho de Equipamento , Interface Usuário-Computador
14.
Clin Nucl Med ; 49(7): 695-697, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38768160

RESUMO

ABSTRACT: 64 Cu-DOTATATE PET/CT of a 44-year-old man with an ileal neuroendocrine tumor demonstrated the primary tumor, local nodal metastases, and a pericaval nodal metastasis. Localization of the pericaval node during surgery may be difficult, thus 4.4 mCi of 111 In-pentetreotide was administered before surgery to assist with localization and resection. At surgery, the pericaval nodal metastasis was readily detected by gamma probe, which could then be resected and pathologically proven to be a metastasis. This demonstrates the use of somatostatin receptor-targeted imaging for intraoperative localization of an otherwise difficult to surgically localize metastasis. Without intraoperative somatostatin receptor-targeted radiosurgery, disease may have been incompletely resected.


Assuntos
Neoplasias do Íleo , Tumores Neuroendócrinos , Radiocirurgia , Somatostatina , Humanos , Masculino , Adulto , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/cirurgia , Tumores Neuroendócrinos/patologia , Neoplasias do Íleo/diagnóstico por imagem , Neoplasias do Íleo/cirurgia , Neoplasias do Íleo/patologia , Somatostatina/análogos & derivados , Metástase Linfática , Neoplasias Retroperitoneais/diagnóstico por imagem , Neoplasias Retroperitoneais/cirurgia , Neoplasias Retroperitoneais/patologia , Período Intraoperatório , Cirurgia Assistida por Computador , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada
15.
Int J Implant Dent ; 10(1): 28, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38819752

RESUMO

PURPOSE: The rise of stereolithographic surgical guides and digital workflow, combined with a better knowledge of materials and loading principle, has enabled the placement of the temporary prosthesis at the time of implant placement. This scoping review aimed to assess the current knowledge available on stackable guides. METHODS: The review focused on fully edentulous or requiring total edentulism patients. The procedure studied was the use of stackable guides for edentulous patients in order to place immediate temporary prostheses. The clinical endpoint was immediate placement of the provisional prosthesis after surgery combined with a prior bone reduction using a stackable guide. RESULTS: 12 case reports or case series articles met inclusion criteria, which did not allow an analysis by a systematic review. The included studies were case reports or case series. Most of the articles showed a base stabilized by 3 or 4 bone-pins, anchored in buccal or lingual part. Regarding the accuracy of bone reduction (ranged from 0.0248 mm to 1.98 mm) and implant placement when compared to planned, only 4 articles reported quantitative data. 11 articles showed an immediate loading with the transitional prosthesis after implant placement. CONCLUSIONS: There are as yet no prospective or comparative studies on the efficiency of this technique. In a reliable way, stackable guides seem to be able to guide the practitioner from the flap elevation to the placement of the temporary screw-retained implant supported prosthesis. Given the lack of studies in this specific field of guided surgery, further studies are needed to confirm the clinical relevance of this technique.


Assuntos
Implantação Dentária Endóssea , Humanos , Implantação Dentária Endóssea/métodos , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/instrumentação , Carga Imediata em Implante Dentário/métodos , Boca Edêntula/cirurgia
16.
BMC Musculoskelet Disord ; 25(1): 396, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38773483

RESUMO

PURPOSE: This systematic review aims to provide an overview of the current knowledge on the role of the metaverse, augmented reality, and virtual reality in reverse shoulder arthroplasty. METHODS: A systematic review was performed using the PRISMA guidelines. A comprehensive review of the applications of the metaverse, augmented reality, and virtual reality in in-vivo intraoperative navigation, in the training of orthopedic residents, and in the latest innovations proposed in ex-vivo studies was conducted. RESULTS: A total of 22 articles were included in the review. Data on navigated shoulder arthroplasty was extracted from 14 articles: seven hundred ninety-three patients treated with intraoperative navigated rTSA or aTSA were included. Also, three randomized control trials (RCTs) reported outcomes on a total of fifty-three orthopedics surgical residents and doctors receiving VR-based training for rTSA, which were also included in the review. Three studies reporting the latest VR and AR-based rTSA applications and two proof of concept studies were also included in the review. CONCLUSIONS: The metaverse, augmented reality, and virtual reality present immense potential for the future of orthopedic surgery. As these technologies advance, it is crucial to conduct additional research, foster development, and seamlessly integrate them into surgical education to fully harness their capabilities and transform the field. This evolution promises enhanced accuracy, expanded training opportunities, and improved surgical planning capabilities.


Assuntos
Artroplastia do Ombro , Realidade Aumentada , Realidade Virtual , Humanos , Artroplastia do Ombro/métodos , Cirurgia Assistida por Computador/educação , Cirurgia Assistida por Computador/métodos , Articulação do Ombro/cirurgia
17.
Radiologie (Heidelb) ; 64(6): 503-514, 2024 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-38780657

RESUMO

The aim of this article is to provide an overview on the most frequently applied image-guided, percutaneous, local ablative techniques for treatment of primary and secondary liver tumors. The technical procedures of microwave ablation (MWA) and radiofrequency ablation (RFA) are presented. The pre-interventional diagnostics, indications and feasibility are also discussed, taking the current national guidelines into consideration. Finally, treatment outcomes and recommendations on post-interventional imaging following local tumor ablation are presented.


Assuntos
Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Micro-Ondas/uso terapêutico , Ablação por Cateter/métodos , Ablação por Radiofrequência/métodos , Cirurgia Assistida por Computador/métodos , Técnicas de Ablação/métodos , Cuidados Pré-Operatórios/métodos , Resultado do Tratamento
18.
J Cardiothorac Surg ; 19(1): 304, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38816751

RESUMO

BACKGROUND: This retrospective study aimed to compare the efficacy and safety of one-stage computed tomography (OSCT)- to that of two-stage computed tomography (TSCT)-guided localization for the surgical removal of small lung nodules. METHODS: We collected data from patients with ipsilateral pulmonary nodules who underwent localization before surgical removal at Veteran General Hospital Kaohsiung between October 2017 and January 2022. The patients were divided into the OSCT and TSCT groups. RESULTS: We found that OSCT significantly reduced the localization time and risky time compared to TSCT, and the success rate of localization and incidence of pneumothorax were similar in both groups. However, the time spent under general anesthesia was longer in the OSCT group than in the TSCT group. CONCLUSIONS: The OSCT-guided approach to localize pulmonary nodules in hybrid operation room is a safe and effective technique for the surgical removal of small lung nodules.


Assuntos
Neoplasias Pulmonares , Tomografia Computadorizada por Raios X , Humanos , Estudos Retrospectivos , Masculino , Tomografia Computadorizada por Raios X/métodos , Feminino , Pessoa de Meia-Idade , Neoplasias Pulmonares/cirurgia , Neoplasias Pulmonares/diagnóstico por imagem , Idoso , Pneumonectomia/métodos , Nódulos Pulmonares Múltiplos/cirurgia , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulo Pulmonar Solitário/cirurgia , Nódulo Pulmonar Solitário/diagnóstico por imagem , Cirurgia Assistida por Computador/métodos
19.
Int J Implant Dent ; 10(1): 27, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38819712

RESUMO

OBJECTIVE: To address the instability in implant surgical guides, this technique proposes an alternative anchoring mechanism in the stackable metal surgical guides utilizing cone-wedge anchors for improved stability. METHODS: Postoperative implant position superimposed onto the preoperatively planned design using Mimics Medical 21.0 and Materialise Magics 24.0 to assess 3D coronal implant deviation, 3D apical implant deviation, and implant angular deviation. RESULTS: Postoperative cone-beam computed tomography (CBCT) revealed a high level of precision in the implant placement, with an average 0.97 mm deviation at implant coronal region, 1.56 mm at implant apexes, and 2.95° angular deviation. CONCLUSION: This technique introduces a novel cone-wedge anchoring mechanism to enhance the stability of stackable metal surgical guide templates, addressing inherent instability issues. The utilization of this approach significantly improves the accuracy of implant placement procedures.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Implantação Dentária Endóssea/métodos , Implantação Dentária Endóssea/instrumentação , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/instrumentação , Metais , Imageamento Tridimensional/métodos
20.
J Craniofac Surg ; 35(4): 1280-1283, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38738867

RESUMO

Craniofacial fibrous dysplasia (CFD) is a rare developmental disease of bone, which typically presents as a painless, expansile mass causing deformity of the craniofacial skeleton. In rare circumstances, compression of neurovascular structures may arise, causing symptoms such as pain, visual impairment, and hearing loss. Traditionally, CFD debulking has been performed with "freehand" techniques using preoperative imaging and anthropometric norms to determine the ideal amount of tissue removal. The advent of computer-assisted surgery, computer-aided design, and computer-aided manufacturing (CAD/CAM) has revolutionized the management of CFD. Surgeons can now fabricate patient-specific osteotomy/ostectomy guides, allowing for increased accuracy in bone removal and improved cosmetic outcomes. This series of 3 cases describe our institution's technique using patient-specific ostectomy "depth guides", which allow for maximum removal of fibro-osseous tissue while sparing deep and adjacent critical structures. These techniques can be widely applied to the craniofacial skeleton to assist in the surgical management of CFD.


Assuntos
Displasia Fibrosa Craniofacial , Osteotomia , Cirurgia Assistida por Computador , Humanos , Cirurgia Assistida por Computador/métodos , Feminino , Osteotomia/métodos , Displasia Fibrosa Craniofacial/cirurgia , Displasia Fibrosa Craniofacial/diagnóstico por imagem , Masculino , Desenho Assistido por Computador , Tomografia Computadorizada por Raios X , Adulto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...