Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 13.381
Filtrar
1.
J Long Term Eff Med Implants ; 34(4): 23-32, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38842230

RESUMO

The incidence of proximal femur fractures is increasing due to aging of the population. Intramedullary nails are the mainstay of treatment for intertrochanteric hip fractures mainly due to their better biomechanical properties compared to dynamic hip screw devices, shorter operative time, and less blood loss during surgery. However intramedullary nail fixation is not devoid of complications. The purpose of this study is to look at complications related to intramedullary nailing for intertrochanteric hip fractures in a major trauma center. A retrospective study was conducted including all patients having suffered an intertrochanteric femur fracture and treated with intramedullary nails from October 1, 2020, to October 1, 2022, in the Orthopaedic Surgery Clinic. The intramedullary hip systems used were the Stryker Gamma3 Nail and the VITUS PF Nail. All complications following the postoperative period were recorded in detail. Overall, 240 patients with a mean age of 82.3 years treated with hip intramedullary devices were identified. Superior cutout of the lag screw in two patients (females 90 and 87 years old) was identified 8 and 10 weeks following initial surgery. Avascular necrosis (AVN) of the femoral head was identified in one patient (male 81 years old) which occurred 12 weeks postoperatively. All three cases were revised by replacing the nail with cemented hemiarthroplasty. Periprosthetic fractures occurred in an 88-year-old male and a 73-year-old female following an injury distal to the stem and were managed by replacing the nail with a long stem device (Long Gamma3). One case of metalwork fracture was also recorded. There are many advantages in managing intertrochanteric hip fractures with intramedullary hip devices such as shorter theater time, less blood loss, and improved biomechanical properties. However, complications such as cutout of the lag screw, AVN, and periprosthetic fracture are serious and require complex revision surgery.


Assuntos
Pinos Ortopédicos , Fixação Intramedular de Fraturas , Fraturas do Quadril , Complicações Pós-Operatórias , Humanos , Estudos Retrospectivos , Fixação Intramedular de Fraturas/efeitos adversos , Fixação Intramedular de Fraturas/instrumentação , Feminino , Fraturas do Quadril/cirurgia , Masculino , Idoso de 80 Anos ou mais , Pinos Ortopédicos/efeitos adversos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Idoso , Parafusos Ósseos/efeitos adversos , Necrose da Cabeça do Fêmur/cirurgia , Necrose da Cabeça do Fêmur/etiologia
2.
Clin Orthop Surg ; 16(3): 363-373, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38827761

RESUMO

Background: Operative management with intramedullary nail fixation remains the definitive treatment of choice for osteoporotic subtrochanteric (ST) fractures; however, there remains no consensus regarding the proper nail length. We aimed to use 3-dimensional finite element (FE) analysis to determine the optimal nail length for the safe fixation of osteoporotic ST fractures. Methods: Nine modes of FE models were constructed using 9 different lengths of cephalomedullary nails (short nails: 170, 180, and 200 mm; long nails: 280, 300, 320, 340, 360, and 380 mm) from the same company. The interfragmentary motion was analyzed. Additionally, the peak von Mises stress (PVMS) in the cortical bone, cancellous bone of the femoral head, and the nail were measured, and the yielding risk for each subject was investigated. Results: Long nails were associated with less interfragmentary motion. In the cortical bone, the PVMS of short nails was observed at the distal locking screw holes of the femoral medial cortex; however, in long nails, the PVMS was observed at the lag screw holes on the lateral cortex. The mean yielding risk of long nails was 40.1% lower than that of short nails. For the cancellous bone of the femoral head, the PVMS in all 9 FE models was in the same area: at the apex of the femoral head. There was no difference in the yielding risk between short and long nails. For implants, the PVMS was at the distal locking screw hole of the nail body in the short nails and the nail body at the fracture level in the long nails. The mean yielding risk was 74.9% lower for long nails than that for short nails. Conclusions: Compared to short nails, long nails with a length of 320 mm or more showed less interfragmentary motion and lower yielding risk in low-level osteoporotic ST fractures. The FE analysis supports long nails as a safer option than short nails, especially for treating transverse-type low-level osteoporotic ST fractures.


Assuntos
Pinos Ortopédicos , Análise de Elementos Finitos , Fixação Intramedular de Fraturas , Fraturas do Quadril , Fraturas por Osteoporose , Humanos , Fraturas por Osteoporose/cirurgia , Fixação Intramedular de Fraturas/métodos , Fixação Intramedular de Fraturas/instrumentação , Fraturas do Quadril/cirurgia , Feminino , Idoso
3.
Clin Orthop Surg ; 16(3): 397-404, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38827762

RESUMO

Background: The objective of this study was to investigate the incidence of osteonecrosis of the femoral head (ONFH) after cephalomedullary nailing in elderly patients with pertrochanteric fractures and to analyze the risk factors related to ONFH. Methods: A total of 689 consecutive patients with cephalomedullary nailing for pertrochanteric fractures at our hospital were recruited. Of these, 368 patients who met the inclusion criteria were finally enrolled. ONFH after cephalomedullary nailing was identified by reviewing patients' electronic charts and serial radiographs. The ONFH group was then compared with the non-ONFH group. Results: ONFH was identified in 9 of 368 patients (2.4%). The time to diagnosis of ONFH averaged 23.8 months (range, 5-54 months) after index surgery. The mean age, body mass index, and bone mineral density (T-score in femur neck) were 84.1 ± 7.1 years, 23.7 ± 3.6 kg/m2, and -3.1 ± 0.7 kg/m2, respectively. The times from injury to surgery, from admission to surgery, and operation time averaged 4.2 ± 2.7 days, 3.6 ± 2.6 days, and 87.2 ± 30.0 minutes, respectively. Among 9 patients, 3 underwent conversion arthroplasty. The ONFH group had advanced age (p = 0.029), more basicervical fracture components (p = 0.002), and inadequate reduction (p = 0.045) compared to the non-ONFH group. On multivariate analysis, advanced age (odds ratio [OR], 1.61;, p = 0.022), basicervical fracture components (OR, 24.58; p = 0.001), and inadequate reduction (OR, 4.11; p = 0.039) were identified as risk factors of ONFH. Conclusions: Although ONFH is relatively rare after cephalomedullary nailing for pertrochanteric fractures in elderly patients, its risk may increase with advanced age, basicervical fracture components, and inadequate reduction. Therefore, in patients with these risk factors, meticulous and longer follow-up is needed even after bone union.


Assuntos
Necrose da Cabeça do Fêmur , Fixação Intramedular de Fraturas , Fraturas do Quadril , Humanos , Masculino , Feminino , Fatores de Risco , Idoso , Idoso de 80 Anos ou mais , Fraturas do Quadril/cirurgia , Fixação Intramedular de Fraturas/efeitos adversos , Fixação Intramedular de Fraturas/métodos , Incidência , Necrose da Cabeça do Fêmur/cirurgia , Necrose da Cabeça do Fêmur/etiologia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Pinos Ortopédicos , Estudos Retrospectivos
4.
J Orthop Surg Res ; 19(1): 332, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38831325

RESUMO

INTRODUCTION: Charcot arthropathy is a progressive disorder of the ankle and foot joints that can lead to foot deformity and instability. Surgical intervention is often necessary for deformity and ulcer management during the chronic phase. The device used for arthrodesis remains a challenge. METHODS: This clinical trial study included diabetic patients aged 40 years or older with Charcot foot. Lateral approach with lateral malleolar osteotomy was used to access the ankle joints and remove the cartilage. A small incision was made on the plantar aspect of the foot to pass an appropriately sized intramedullary nail. Demographic information, medical history, surgical details and Clinical data were collected at 2-week and 1-year follow-ups using the Ankle-Hindfoot Scale (AOFAS) score and the EuroQol 5-Dimensional 5-Level (EQ-5D-5L) health utility score. RESULTS: Twenty-six patients with a mean age of 63 ± 0.23 years were included in the study. The findings showed significant improvements in AOFAS questionnaire items related to pain score, length of the walk, walking surfaces, walking disorders, sagittal alignment, back leg alignment, sustainability, alignment and the total score (P value < 0.001). The EQ-5D-5L questionnaire also showed a significant improvement in the total score (P value = 0.002). CONCLUSION: This study provides evidence supporting the effectiveness of tibiotalocalcaneal arthrodesis by hindfoot nailing in diabetic patients with Charcot foot joints and demonstrated comparable and superior outcomes in terms of patient satisfaction and complication rate when compared to previous studies.


Assuntos
Articulação do Tornozelo , Artrodese , Artropatia Neurogênica , Pinos Ortopédicos , Qualidade de Vida , Humanos , Pessoa de Meia-Idade , Artrodese/métodos , Artrodese/instrumentação , Feminino , Masculino , Artropatia Neurogênica/cirurgia , Articulação do Tornozelo/cirurgia , Articulação do Tornozelo/diagnóstico por imagem , Idoso , Resultado do Tratamento , Seguimentos , Tíbia/cirurgia , Adulto
5.
BMC Musculoskelet Disord ; 25(1): 456, 2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38851687

RESUMO

BACKGROUND: Osteosynthesis using antegrade intramedullary nailing for humeral shaft fractures yields satisfactory bone union rates; however, it may adversely affect postoperative shoulder function. To date, factors affecting mid- or long-term shoulder functional outcomes following intramedullary nail fixation have not been clarified. In this study, we aimed to identify the risk factors for poor mid-term functional outcomes over 5 years postoperatively following antegrade intramedullary nail osteosynthesis for humeral shaft fractures. METHODS: We retrospectively identified 33 patients who underwent surgery using an antegrade intramedullary nail for acute traumatic humeral shaft fractures and were followed up for at least 5 years postoperatively. We divided the patients into clinical failure and no clinical failure groups using an age- and sex-adjusted Constant score of 55 at the final follow-up as the cutoff value. We compared preoperative, perioperative, and postoperative factors between the two groups. RESULTS: Five of the 33 patients had poor shoulder functional outcomes (adjusted Constant score < 55) at a mean follow-up of 7.5 years postoperatively. Proximal protrusion of the nail at the time of bone union (P = 0.004) and older age (P = 0.009) were significantly associated with clinical failure in the univariate analyses. Multivariate analysis showed that proximal protrusion of the nail (P = 0.031) was a risk factor for poor outcomes. CONCLUSIONS: The findings of this study provide new information on predictive factors affecting mid-term outcomes following osteosynthesis using antegrade nails. Our results demonstrated that proximal protrusion of the nail was significantly associated with poor mid-term functional shoulder outcomes. Therefore, particularly in older adults, it is essential to place the proximal end of the intramedullary nail below the level of the articular cartilage.


Assuntos
Pinos Ortopédicos , Fixação Intramedular de Fraturas , Fraturas do Úmero , Humanos , Estudos Retrospectivos , Feminino , Masculino , Fixação Intramedular de Fraturas/métodos , Fixação Intramedular de Fraturas/efeitos adversos , Fixação Intramedular de Fraturas/instrumentação , Fraturas do Úmero/cirurgia , Pessoa de Meia-Idade , Adulto , Seguimentos , Fatores de Risco , Idoso , Resultado do Tratamento , Amplitude de Movimento Articular , Articulação do Ombro/cirurgia , Articulação do Ombro/fisiopatologia , Consolidação da Fratura , Recuperação de Função Fisiológica , Adulto Jovem
6.
Can J Surg ; 67(3): E236-E242, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38843942

RESUMO

BACKGROUND: Use of postoperative radiographs after surgical management of supracondylar humerus (SCH) fractures is often based on rote practice rather than evidence. The purpose of this study was to determine the frequency with which 3-week postoperative radiographs at the time of pin removal altered management plans in pediatric SCH fractures that were intraoperatively stable after closed reduction and percutaneous pinning (CRPP). METHODS: We prospectively recruited pediatric patients with SCH fractures managed by CRPP at our institution from June 2020 until June 2022, and reviewed retrospective data on pediatric SCH fractures managed surgically at our institution between April 2008 and March 2015. Patients were assessed for post-CRPP fracture alignment and stability. For prospective patients, we asked clinicians to document their management decision at the 3-week follow-up visit before evaluating the postoperative radiographs. Our primary outcome was change in management because of radiographic findings. RESULTS: Overall, 1066 patients in the retrospective data and 446 prospectively recruited patients met the inclusion criteria. In the prospective group, radiographic findings altered management for 2 patients (0.4%). One patient had slow callus formation and 1 patient was identified as having cubitus varus. Altered management included prolonged immobilization or additional radiographic follow-up. Radiographic findings altered management in 0 (0%) of 175 type II fractures, in 2 (0.9%) of 221 type III fractures, and in 0 (0%) of 44 type IV fractures. We obtained similar findings from retrospective data. CONCLUSION: Rote use of 3-week postoperative radiographs after surgical management of SCH fractures that are intraoperatively stable has minimal utility. Eliminating rote postoperative radiographs for SCH fractures can decrease the time and financial burdens on families and health care systems without affecting patient outcomes.


Assuntos
Fraturas do Úmero , Radiografia , Humanos , Fraturas do Úmero/cirurgia , Fraturas do Úmero/diagnóstico por imagem , Estudos Retrospectivos , Criança , Masculino , Feminino , Pré-Escolar , Pinos Ortopédicos , Redução Fechada/métodos , Estudos Prospectivos , Cuidados Pós-Operatórios/métodos
7.
Sci Rep ; 14(1): 10322, 2024 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-38710745

RESUMO

Blade cut-out is a common complication when using proximal femoral nail anti-rotation (PFNA) for the treatment of intertrochanteric fractures. Although cement augmentation has been introduced to overcome the cut-out effect, the micromechanics of this approach remain to be clarified. While previous studies have developed finite element (FE) models based on lab-prepared or cadaveric samples to study the cement-trabeculae interface, their demanding nature and inherent disadvantages limit their application. The aim of this study was to develop a novel 'one-step forming' method for creating a cement-trabeculae interface FE model to investigate its micromechanics in relation to PFNA with cement augmentation. A human femoral head was scanned using micro-computed tomography, and four volume of interest (VOI) trabeculae were segmented. The VOI trabeculae were enclosed within a box to represent the encapsulated region of bone cement using ANSYS software. Tetrahedral meshing was performed with Hypermesh software based on Boolean operation. Finally, four cement-trabeculae interface FE models comprising four interdigitated depths and five FE models comprising different volume fraction were established after element removal. The effects of friction contact, frictionless contact, and bond contact properties between the bone and cement were identified. The maximum micromotion and stress in the interdigitated and loading bones were quantified and compared between the pre- and post-augmentation situations. The differences in micromotion and stress with the three contact methods were minimal. Micromotion and stress decreased as the interdigitation depth increased. Stress in the proximal interdigitated bone showed a correlation with the bone volume fraction (R2 = 0.70); both micromotion (R2 = 0.61) and stress (R2 = 0.93) at the most proximal loading region exhibited a similar correlation tendency. When comparing the post- and pre-augmentation situations, micromotion reduction in the interdigitated bone was more effective than stress reduction, particularly near the cement border. The cementation resulted in a significant reduction in micromotion within the loading bone, while the decrease in stress was minimal. Noticeable gradients of displacement and stress reduction can be observed in models with lower bone volume fraction (BV/TV). In summary, cement augmentation is more effective at reducing micromotion rather than stress. Furthermore, the reinforcing impact of bone cement is particularly prominent in cases with a low BV/TV. The utilization of bone cement may contribute to the stabilization of trabecular bone and PFNA primarily by constraining micromotion and partially shielding stress.


Assuntos
Cimentos Ósseos , Pinos Ortopédicos , Análise de Elementos Finitos , Fraturas do Quadril , Humanos , Fraturas do Quadril/cirurgia , Microtomografia por Raio-X , Fenômenos Biomecânicos , Cabeça do Fêmur , Rotação
8.
BMC Musculoskelet Disord ; 25(1): 389, 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38762453

RESUMO

BACKGROUND: Several methods have been used for the treatment of pediatric distal femoral fractures, such as elastic stable intramedullary nail (ESIN), external fixator (EF) and plate osteosynthesis, but there has been no consensus about the optimal method. The purpose of this study was to compare the clinical outcome between EF and ESIN techniques used in metaphyseal-diaphyseal junction (MDJ) fractures of the pediatric distal femur. METHODS: We retrospectively analyzed operatively treated MDJ fractures of pediatric distal femur between January 2015 and January 2022. Patient charts were reviewed for demographics, injury and data of radiography. All of the patients were divided into EF and ESIN groups according to the operation techniques. Malalignment was defined as more than 5 degrees of angular deformity in either plane. Clinical outcomes were measured by Flynn scoring system. RESULTS: Thirty-eight patients were included in this study, among which, 23 were treated with EF, and 15 with ESIN. The mean follow-up time was 18 months (12-24 months). At the final follow-up, all of the fractures were healed. Although there were no statistical differences between the two groups in demographic data, length of stay, estimated blood loss (EBL), rate of open reduction, time to fracture healing and Flynn score, the EF was superior to ESIN in operative time, fluoroscopic exposure and time to partial weight-bearing. The EF group had a significantly higher rate of skin irritation, while the ESIN had a significantly higher rate of malalignment. CONCLUSION: EF and ESIN are both effective methods in the treatment of MDJ fractures of the pediatric distal femur. ESIN is associated with lower rates of skin irritation. However, EF technique has the advantages of shorter operative time, reduced fluoroscopic exposure, and shorter time to partial weight-bearing, as well as lower incidence of malalignment. LEVEL OF EVIDENCE: Level III.


Assuntos
Pinos Ortopédicos , Fixadores Externos , Fraturas do Fêmur , Fixação Intramedular de Fraturas , Humanos , Feminino , Masculino , Estudos Retrospectivos , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/diagnóstico por imagem , Criança , Fixação Intramedular de Fraturas/instrumentação , Fixação Intramedular de Fraturas/métodos , Resultado do Tratamento , Estudos de Casos e Controles , Consolidação da Fratura , Diáfises/lesões , Diáfises/cirurgia , Diáfises/diagnóstico por imagem , Pré-Escolar , Seguimentos , Adolescente , Fêmur/cirurgia , Fêmur/diagnóstico por imagem
9.
Eur Rev Med Pharmacol Sci ; 28(8): 3165-3175, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38708475

RESUMO

OBJECTIVE: Periprosthetic fractures following total knee replacement are rare but challenging. The goal of the treatment is to achieve the most stable fixation that allows early mobilization. Therefore, the aim of this study was to evaluate the biomechanical results of the use of different fixation systems in the treatment of distal femur periprosthetic fractures with finite element analysis. MATERIALS AND METHODS: A total knee prosthesis was implanted in Sawbone femur models. A transverse fracture line was created in the supracondylar region and was fixed in four different groups. In group 1, fracture line fixation was fixed using retrograde intramedullary nailing. In group 2, fixation was applied using a lateral anatomic distal femoral. In group 3, in addition to the fixation made in group 1, a lateral anatomic distal femoral plate was used. In group 4, in addition to the fixation made in group 2, a 3.5 mm Limited Contact Dynamic Compression Plate (LC-DCP) was applied medially. Computed Tomography (CT) scans were taken of the created models and were converted to three-dimensional models. Axial and rotational loading forces were applied to all the created models. RESULTS: The least deformation with axial loading was observed in the double plate group. Group 3 was determined to be more advantageous against rotational forces. The greatest movement in the fracture line was found in group 2. The application of the medial plate was determined to reduce the tension on the lateral plate and increase stability in the fracture line. CONCLUSIONS: Combining a lateral anatomic plate with intramedullary nailing or a medial plate was seen to be biomechanically more advantageous than using a lateral plate or intramedullary nailing alone in the treatment of distal femoral periprosthetic fractures.


Assuntos
Artroplastia do Joelho , Pinos Ortopédicos , Placas Ósseas , Fraturas do Fêmur , Análise de Elementos Finitos , Fixação Intramedular de Fraturas , Fraturas Periprotéticas , Artroplastia do Joelho/efeitos adversos , Fraturas do Fêmur/cirurgia , Humanos , Fraturas Periprotéticas/cirurgia , Fixação Intramedular de Fraturas/instrumentação , Parafusos Ósseos , Fenômenos Biomecânicos
10.
Medicina (Kaunas) ; 60(5)2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38792901

RESUMO

Background and Objectives: This retrospective cohort study analyzes mechanical complications in hip fracture surgery using the Trochanteric Fixation Nail-Advanced (TFNA) implant. It investigates the correlation of these complications with demographic, intraoperative, and radiological factors, aiming to identify associated risk factors and suggest improvements in clinical surveillance and treatment strategies. Materials and Methods: We enrolled 253 patients diagnosed with pertrochanteric hip fractures treated between 2017 and 2021, with 126 meeting the criteria for a minimum 6-month follow-up. Data on demographics, American Anesthesia Association Classification (ASA), comorbidities, AO/OTA [AO (Arbeitsgemeinschaft für Osteosynthesefragen)/OTA (Orthopedic Trauma Association)] fracture classification, procedural details, and time to failure were collected. Radiographs were evaluated for reduction quality, the tip-apex distance (TAD), progressive varus deviation, and identification of mechanical complications. Statistical analysis was performed using SPSS software. Results: The predominant AO/OTA fracture classification was 31A2 in 67 cases (52.7%). Reduction quality was deemed good or acceptable in 123 cases (97.6%). The mean time to failure was 4.5 months (range: 2.2-6). The average TAD was 18 mm (range: 1.2-36), with a mean progressive varus deviation of 2.44° (range: 1.30-4.14). A good or acceptable reduction quality was observed in 97.6% of cases. Mechanical complications occurred in 21.4% of patients, with significant associations found with the lateral cortex fracture, use of a TFNA implant with a 130° angle, open reduction, and absence of prior osteoporosis treatment. Conclusions: The study provides insights into mechanical complications in proximal femur fractures treated with the TFNA nail, emphasizing the need for enhanced clinical and radiographic surveillance, especially in patients without osteoporosis treatment. Our findings support the necessity for further clinical studies comparing these outcomes with other implant designs and underscore the importance of personalized treatment strategies to reduce complication rates.


Assuntos
Fixação Intramedular de Fraturas , Complicações Pós-Operatórias , Humanos , Estudos Retrospectivos , Feminino , Masculino , Fixação Intramedular de Fraturas/métodos , Fixação Intramedular de Fraturas/efeitos adversos , Fixação Intramedular de Fraturas/instrumentação , Idoso , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Fraturas do Quadril/cirurgia , Pinos Ortopédicos , Estudos de Coortes , Fraturas do Fêmur/cirurgia , Fatores de Risco , Fraturas Proximais do Fêmur
11.
Cir Cir ; 92(2): 211-218, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38782385

RESUMO

OBJECTIVES: The aim of the study was to investigate the clinical effect of stainless-steel wire fixation on the early mouth-opening movement of an intracapsular fracture involving the condylar process. MATERIALS AND METHODS: In this study, patients who underwent mandibular condylar intracapsular fracture surgery in our hospital from 2012 to 2020 were selected as research subjects. A total of 44 patients received steel wire internal fixation treatment, 32 patients received titanium plate-and-nail rigid internal fixation, and 28 patients underwent conservative non-surgical treatment. RESULTS: For the patients in the stainless-steel wire group, the degree of mouth opening reached normal levels of 3.7 cm approximately 10 days after surgery. The recovery time for the patients in the titanium plate-and-nail rigid internal-fixation group was 21 days, while the patients in the conservative treatment group needed 60 days to recover. CONCLUSION: The treatment of fixation with a stainless-steel wire for intracapsular condylar fracture reduced the time taken to perform mouth-opening exercises and improved the recovery rate of patients.


OBJETIVO: Explorar el efecto clínico de la fijación de alambre de acero inoxidable en el movimiento temprano de apertura de la boca en la fractura interna del cóndilo. MÉTODO: Este estudio seleccionó a pacientes que se sometieron a cirugía de fractura intracapsular de cóndilo en nuestro hospital de 2012 a 2020 como sujetos de investigación. Un total de 44 pacientes recibieron tratamiento de fijación interna de alambre de acero, 32 recibieron placa de titanio y fijación interna con clavos, y 28 recibieron tratamiento conservador no quirúrgico. RESULTADOS: En los pacientes del grupo de alambre de acero inoxidable, alrededor de 10 días después de la cirugía el grado de apertura de la boca alcanzó un valor normal de 3.7 cm. El tiempo de recuperación de los pacientes en el grupo de fijación interna con clavos y placa de titanio fue de 21 días, mientras que los pacientes en el grupo de tratamiento conservador tardaron 60 días en recuperarse. CONCLUSIONES: La fijación con alambre de acero inoxidable para el tratamiento de la fractura intracapsular del cóndilo acorta el tiempo hasta la apertura de la boca y mejora la tasa de recuperación de los pacientes.


Assuntos
Placas Ósseas , Fios Ortopédicos , Fixação Interna de Fraturas , Côndilo Mandibular , Fraturas Mandibulares , Aço Inoxidável , Humanos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fraturas Mandibulares/cirurgia , Côndilo Mandibular/lesões , Côndilo Mandibular/cirurgia , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Titânio , Amplitude de Movimento Articular , Pinos Ortopédicos , Adulto Jovem , Estudos Retrospectivos
12.
J Robot Surg ; 18(1): 221, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38780662

RESUMO

Intramedullary nail fixation of intertrochanteric fractures assisted by orthopedic surgical robot navigation is a new surgical method, but there are few studies comparing its efficacy with traditional intramedullary nail fixation. We aimed to assess whether robot-assisted internal fixation confers certain surgical advantages through a literature review. PubMed, EMBASE, Cochrane Library, China National Knowledge Infrastructure (CNKI) and Wan fang Data Knowledge service Platform were searched to collect randomized and non-randomized studies on patients with calcaneal fractures. Five studies were identified to compare the clinical indexes. For the clinical indexes, the technology of robot-assisted is generally feasible, in time to operation, intraoperative fluoroscopy times, blood loss, pine insertion, tip apex distance (TAD), and Harris score (P < 0.05). However, on the complication and excellent and good rate after operation did not show good efficacy compared with the traditional group (P > 0.05). Based on the current evidence, For the short-term clinical index, the advantages of robot-assisted are clear. The long-term clinical effects of the two methods are also good, but the robot-assisted shows better. However, the quality of some studies is low, and more high-quality randomized controlled trials (RCTs) are needed for further verification.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Quadril , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Fraturas do Quadril/cirurgia , Fixação Intramedular de Fraturas/métodos , Resultado do Tratamento , Duração da Cirurgia , Perda Sanguínea Cirúrgica/estatística & dados numéricos , Pinos Ortopédicos
13.
BMC Musculoskelet Disord ; 25(1): 405, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38783225

RESUMO

Femoral head varus is an important complication in intertrochanteric fracture patients treated with proximal femoral nail anti-rotation (PFNA) fixation. Theoretically, extending the length of the intramedullary nail could optimize fixation stability by lengthening the force arm. However, whether extending the nail length can optimize patient prognosis is unclear. In this study, a review of imaging data from intertrochanteric fracture patients with PFNA fixation was performed, and the length of the intramedullary nail in the femoral trunk and the distance between the lesser trochanter and the distal locking screw were measured. The femoral neck varus status was judged at the 6-month follow-up. The correlation coefficients between nail length and femoral neck varus angle were computed, and linear regression analysis was used to determine whether a change in nail length was an independent risk factor for femoral neck varus. Moreover, the biomechanical effects of different nail lengths on PFNA fixation stability and local stress distribution have also been verified by numerical mechanical simulations. Clinical review revealed that changes in nail length were not significantly correlated with femoral head varus and were also not an independent risk factor for this complication. In addition, only slight biomechanical changes can be observed in the numerical simulation results. Therefore, commonly used intramedullary nails should be able to meet the needs of PFNA-fixed patients, and additional procedures for longer nail insertion may be unnecessary.


Assuntos
Pinos Ortopédicos , Fixação Intramedular de Fraturas , Fraturas do Quadril , Humanos , Fenômenos Biomecânicos/fisiologia , Fixação Intramedular de Fraturas/instrumentação , Fixação Intramedular de Fraturas/métodos , Fixação Intramedular de Fraturas/efeitos adversos , Feminino , Masculino , Idoso , Fraturas do Quadril/cirurgia , Fraturas do Quadril/diagnóstico por imagem , Cabeça do Fêmur/cirurgia , Cabeça do Fêmur/diagnóstico por imagem , Idoso de 80 Anos ou mais , Fatores de Risco , Pessoa de Meia-Idade , Simulação por Computador
14.
Sci Rep ; 14(1): 11129, 2024 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-38750240

RESUMO

Elastic stable intramedullary nailing (ESIN) internal fixation is used clinically to treat pathological fractures of bone cysts in children. However, one of the most important complications was removal difficulty. In this study, we aim to analyse the factors which can influence ESIN removal in healed bone cysts in children. From April 2014 to November 2020, the clinical data of 49 children who underwent elastic stable intramedullary nail removal for pathological fractures of the bone cysts in our hospital were retrospectively analysed. The following data, including age, sex, pathological fracture site, with bone graft, number of ESINs, ESIN indwelling time, and extraosseous length of ESIN were collected, and univariate analysis and logistic regression analysis was performed. The frequency of difficulty in ESIN extraction was 44.90% (22/49). The univariate logistic regression analysis showed that age,ESIN indwelling time,with bone garft and extraosseous length of ESIN may be correlated with the difficulty in removing ESIN (P < 0.05), while sex, pathological fracture site, number of ESIN may not be correlated with the difficulty in removing ESIN (P > 0.05).The multivariate logistic regression analysis showed that the ESIN indwelling time was the independent influencing factor for difficulty in removing ESIN (P < 0.05). The factors influencing the ESIN removal in healed bone cysts in children include over 11.79 years old, the long indwelling time of the ESIN(over 10.5 months),with bone graft and short extraosseous length of ESIN(≤ 0.405 cm). These factors influencing ESIN removal in healed bone cysts in children should be considered.


Assuntos
Cistos Ósseos , Fixação Intramedular de Fraturas , Humanos , Feminino , Masculino , Criança , Cistos Ósseos/cirurgia , Fixação Intramedular de Fraturas/métodos , Estudos Retrospectivos , Pré-Escolar , Adolescente , Pinos Ortopédicos , Fraturas Espontâneas/cirurgia , Fraturas Espontâneas/etiologia , Consolidação da Fratura
15.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(5): 613-617, 2024 May 15.
Artigo em Chinês | MEDLINE | ID: mdl-38752250

RESUMO

Objective: To summarize the research progress in the treatment of distal humeral metaphyseal-diaphyseal junction (DHMDJ) fractures in children and to provide reference for clinical practice. Methods: The characteristics and treatment methods of transverse and comminuted DHMDJ fractures in children were summarized and analyzed by referring to relevant literature at home and abroad. Results: DHMDJ fractures in children are not uncommon clinically, with high fracture line position, multi-directional instability, difficult closed reduction in treatment, and easy to cause complications such as coronal and sagittal deformity of the elbow. The Kirschner wire technique was effective for DHMDJ fractures with the fracture line at the middle and low levels, but was prone to iatrogenic ulnar nerve injury. Elastic stable intramedullary nail is suitable for higher-position transverse DHMDJ fractures. However, this technique requires a second operation to remove the internal fixator, and may cause iatrogenic epiphysis plate injury in children. External fixator is a new way to treat DHMDJ fractures, and it can show satisfactory results for transverse and comminuted DHMDJ fractures. However, at present, there are few relevant studies, and most of them focus on biomechanical studies, and the efficacy lacks high-quality clinical research support. Conclusion: The ultimate goal of DHMDJ fracture treatment in children is to restore the anatomical alignment of the fracture and prevent the loss of reduction. The choice of internal fixator depends on the location of the fracture line and the shape of the fracture to provide personalized treatment.


Assuntos
Fixação Interna de Fraturas , Fraturas do Úmero , Humanos , Criança , Fraturas do Úmero/cirurgia , Fixação Interna de Fraturas/métodos , Fios Ortopédicos , Fixadores Externos , Diáfises/lesões , Fraturas Cominutivas/cirurgia , Fixação Intramedular de Fraturas/métodos , Resultado do Tratamento , Placas Ósseas , Pinos Ortopédicos , Fixadores Internos , Pré-Escolar , Articulação do Cotovelo/cirurgia , Consolidação da Fratura
16.
Acta Orthop ; 95: 275-281, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38819402

RESUMO

BACKGROUND AND PURPOSE: Orthopedic trainees frequently perform short antegrade femoral nail osteosynthesis of trochanteric fractures, but virtual reality simulation-based training (SBT) with haptic feedback has been unavailable. We explored a novel simulator, with the aim of gathering validity evidence for an embedded test and setting a credible pass/fail standard allowing trainees to practice to proficiency. PATIENTS AND METHODS: The research, conducted from May to September 2020 across 3 Danish simulation centers, utilized the Swemac TraumaVision simulator for short antegrade femoral nail osteosynthesis. The validation process adhered to Messick's framework, covering all 5 sources of validity evidence. Participants included novice groups, categorized by training to plateau (n = 14) or to mastery (n = 10), and experts (n = 9), focusing on their performance metrics and training duration. RESULTS: The novices in the plateau group and experts had hands-on training for 77 (95% confidence interval [CI] 59-95) and 52 (CI 36-69) minutes while the plateau test score, defined as the average of the last 4 scores, was 75% (CI 65-86) and 96% (CI 94-98) respectively. The pass/fail standard was established at the average expert plateau test score of 96%. All novices in the mastery group could meet this standard and interestingly without increased hands-on training time (65 [CI 46-84] minutes). CONCLUSION: Our study provides supporting validity evidence from all sources of Messick's framework for a simulation-based test in short antegrade nail osteosynthesis of intertrochanteric hip fracture and establishes a defensible pass/fail standard for mastery learning of SBT. Novices who practiced using mastery learning were able to reach the pre-defined pass/fail standard and outperformed novices without a set goal for external motivation.


Assuntos
Pinos Ortopédicos , Competência Clínica , Treinamento por Simulação , Humanos , Treinamento por Simulação/métodos , Fraturas do Quadril/cirurgia , Feminino , Masculino , Adulto , Fixação Interna de Fraturas/educação , Fixação Interna de Fraturas/métodos , Fixação Intramedular de Fraturas/educação , Fixação Intramedular de Fraturas/métodos , Ortopedia/educação , Dinamarca
17.
J Hand Surg Asian Pac Vol ; 29(3): 211-216, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38726499

RESUMO

Background: The pins and rubber traction system (PRTS) has proven effective in managing intra-articular fractures of the proximal interphalangeal joint. However, there is scant evidence in the literature regarding its efficacy in treating distal interphalangeal joint (DIPJ). This study aims to investigate the outcomes of PRTS in the treatment of comminuted intra-articular fractures of the DIPJ. Methods: We conducted a retrospective review of patients with comminuted intra-articular fractures of the DIPJ treated with PRTS between 2017 and 2021. At the final follow-up, we measured and compared the active range of motion (ROM) in both affected and non-injured contralateral fingers. The subjective evaluation utilised the Quick Disabilities of the Arm, Shoulder and Hand (Quick-DASH) questionnaire and the Visual Analogue Scale (VAS). Results: Ten patients with a mean follow-up of 13.2 months (range: 12-17) were included in the study. Fracture locations included the base of the distal phalanx in two patients, the condyle of the middle phalanx in seven and both in one patient. At the final follow-up, the average VAS score was 0.5 (range: 0-2). The average active motion of the DIPJ was 61° (range: 50°-70°) for the injured side and 76° (range: 75°-80°) for the opposite side. The mean range of DIPJ movement was 80% (range: 68%-87%) of the non-injured side. Extension deficits were observed in five patients, with a median deficit value of 10° (range: 5°-10°). The average Quick-DASH score was 2.9 (range: 0-11.3). Conclusions: The PRTS can be considered as an effective surgical technique in managing comminuted intra-articular fractures of the DIPJ. Level of Evidence: Level IV (Therapeutic).


Assuntos
Articulações dos Dedos , Fraturas Cominutivas , Fraturas Intra-Articulares , Amplitude de Movimento Articular , Tração , Humanos , Masculino , Feminino , Estudos Retrospectivos , Fraturas Intra-Articulares/cirurgia , Fraturas Intra-Articulares/terapia , Adulto , Articulações dos Dedos/fisiopatologia , Tração/métodos , Fraturas Cominutivas/cirurgia , Fraturas Cominutivas/terapia , Pessoa de Meia-Idade , Pinos Ortopédicos , Adulto Jovem , Traumatismos dos Dedos/terapia , Avaliação da Deficiência
18.
Bone Joint J ; 106-B(6): 603-612, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38821494

RESUMO

Aims: This study aimed to compare mortality in trochanteric AO/OTA A1 and A2 fractures treated with an intramedullary nail (IMN) or sliding hip screw (SHS). The primary endpoint was 30-day mortality, with secondary endpoints at 0 to 1, 2 to 7, 8 to 30, 90, and 365 days. Methods: We analyzed data from 26,393 patients with trochanteric AO/OTA A1 and A2 fractures treated with IMNs (n = 9,095) or SHSs (n = 17,298) in the Norwegian Hip Fracture Register (January 2008 to December 2020). Exclusions were made for patients aged < 60 years, pathological fractures, pre-2008 operations, contralateral hip fractures, fractures other than trochanteric A1/A2, and treatments other than IMNs or SHSs. Kaplan-Meier and Cox regression analyses adjusted for type of fracture, age, sex, cognitive impairment, American Society of Anesthesiologists (ASA) grade, and time period were conducted, along with calculations for number needed to harm (NNH). Results: In unadjusted analyses, there was no significant difference between IMN and SHS patient survival at 30 days (91.8% vs 91.1%; p = 0.083) or 90 days (85.4% vs 84.5%; p = 0.065), but higher one-year survival for IMNs (74.5% vs 73.3%; p = 0.031) compared with SHSs. After adjustments, no significant difference in 30-day mortality was found (hazard rate ratio (HRR) 0.94 (95% confidence interval (CI) 0.86 to 1.02(; p = 0.146). IMNs exhibited higher mortality at 0 to 1 days (HRR 1.63 (95% CI 1.13 to 2.34); p = 0.009) compared with SHSs, with a NNH of 556, but lower mortality at 8 to 30 days (HRR 0.89 (95% CI 0.80 to 1.00); p = 0.043). No differences were observed in mortality at 2 to 7 days (HRR 0.94 (95% CI 0.79 to 1.11); p = 0.434), 90 days (HRR 0.95 (95% CI 0.89 to 1.02); p = 0.177), or 365 days (HRR 0.97 (95% CI 0.92 to 1.02); p = 0.192). Conclusion: This study found no difference in 30-day mortality between IMNs and SHSs. However, IMNs were associated with a higher mortality at 0 to 1 days and a marginally lower mortality at 8 to 30 days compared with SHSs. The observed differences in mortality were small and should probably not guide choice of treatment.


Assuntos
Pinos Ortopédicos , Parafusos Ósseos , Fixação Intramedular de Fraturas , Fraturas do Quadril , Sistema de Registros , Humanos , Masculino , Feminino , Fraturas do Quadril/cirurgia , Fraturas do Quadril/mortalidade , Noruega/epidemiologia , Idoso , Fixação Intramedular de Fraturas/métodos , Fixação Intramedular de Fraturas/instrumentação , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade
19.
Jt Dis Relat Surg ; 35(2): 276-284, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38727105

RESUMO

OBJECTIVES: This study aimed to compare the efficacy and safety of the intramedullary nail and conventional plate for the treatment of displaced intra-articular calcaneal fractures from clinical comparative trials. MATERIALS AND METHODS: A comprehensive search of English databases was carried out in the Springer, PubMed, ScienceDirect, Web of Science, and Cochrane Library databases until September 2023. Studies on calcaneal fractures treated by an intramedullary nail or a plate were considered for inclusion. Endpoints included duration of operation, length of hospital stay, the Visual Analog Scale (VAS) score, postoperative functional score, radiological parameters, and complications. The mean difference (MD) and risk difference (RD) as the combined variables, as well as the 95% confidence intervals, (CIs) were calculated. RESULTS: Five retrospective controlled studies covering 473 feet at the one-year follow-up met the inclusion criteria. The meta-analysis demonstrated that there were significant differences in the duration of operation (MD: -10.81; 95% CI: -16.32, -5.31; p=0.0001), length of hospital stay (MD: -3.65; 95% CI: -4.35, -2.95; p<0.00001). No significant differences were found regarding postoperative American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot Scale (MD: 0.36; 95% CI: -3.89, 4.61; p=0.87), VAS (MD: 1.95; 95% CI: -0.30, 4.21; p=0.09), or postoperative Böhler angle (MD: 0.94; 95% CI: -0.04, 1.92; p=0.06) between the two groups. The incidence of total complications (RD: -0.31; 95% CI: -0.46, -0.17; p<0.0001) and wound-healing complications (RD: -0.16; 95% CI: -0.30, -0.03; p=0.02) were lower in the intramedullary nail group. There were no significant differences in the incidences of revision surgery, implant removal, superficial wound infection, deep infection, and nonunion. CONCLUSION: Compared to conventional plates, the intramedullary nail showed a shorter duration of operation, reduced length of hospital stay, and fewer postoperative total complications and wound-healing complications in treating displaced intra-articular calcaneal fractures.


Assuntos
Pinos Ortopédicos , Placas Ósseas , Calcâneo , Fixação Intramedular de Fraturas , Humanos , Calcâneo/lesões , Calcâneo/cirurgia , Fixação Intramedular de Fraturas/métodos , Fixação Intramedular de Fraturas/instrumentação , Fixação Intramedular de Fraturas/efeitos adversos , Fraturas Intra-Articulares/cirurgia , Tempo de Internação , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento
20.
Clin Orthop Surg ; 16(2): 194-200, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38562635

RESUMO

Background: Reverse oblique intertrochanteric fractures (ROFs) are unstable extracapsular hip fractures that present a mechanical challenge. These fractures are classified as AO/Orthopaedic Trauma Association (OTA) 31-A3 according to the Trauma Association classification system and can further be subclassified into 3 subtypes based on their specific characteristics. The study aimed to evaluate and compare the radiographic and clinical outcomes of the 3 subtypes of ROFs. Methods: A retrospective study was conducted at a single high-volume, tertiary center, where data were collected from electronic medical records of consecutive patients who underwent surgical fixation of AO/OTA 31-A3 fractures. Patients with less than 1-year follow-up, pathological fractures, and revision surgery were excluded. The subtypes of fractures were classified as 31-A3.1 (simple oblique), 31-A3.2 (simple transverse), and 31-A3.3 (wedge or multi-fragmentary). The operation was done using 4 different fixation methods, and radiological evaluation was performed at routine intervals. Results: The final population consisted of 265 patients (60.8% women) with a mean age of 77.4 years (range, 50-100 years) and the mean follow-up time was 35 months (range, 12-116 months). The incidence of medical complications was similar across the groups. However, there was a trend toward a higher incidence of orthopedic complications and revision rates in the 31-A3.2 group, although this was not statistically significant (p = 0.21 and p = 0.14, respectively). Conclusions: Based on the findings of this study, no significant differences were observed between the groups, indicating that the subclassifications of AO/OTA 31-A3 fractures do not have a significant impact on surgical outcomes or the occurrence of postoperative complications.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Quadril , Humanos , Feminino , Idoso , Masculino , Estudos Retrospectivos , Pinos Ortopédicos , Fixação Intramedular de Fraturas/métodos , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/cirurgia , Complicações Pós-Operatórias/epidemiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...