Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.138
Filtrar
1.
J Environ Manage ; 363: 121364, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38850917

RESUMO

Recycling silicon cutting waste (SCW) plays a pivotal role in reducing environmental impact and enhancing resource efficiency within the semiconductor industry. Herein SCW was utilized to prepare SiC and ultrasound-assisted leaching was investigated to purify the obtained SiC and the leaching factors were optimized. The mixed acids of HF/H2SO4 works efficiently on the removal of Fe and SiO2 due to that HF can react with SiO2 and Si and then expose the Fe to H+. The assistance of ultrasound can greatly improve the leaching of Fe, accelerate the leaching rate, and lower the leaching temperature. The optimal leaching conditions are HF-H2SO4 ratio of 1:3, acid concentration of 3 mol/L, temperature of 50 °C, ultrasonic frequency of 45 kHz and power of 210 W, and stirring speed of 300 rpm. The optimal leaching ratio of Fe is 99.38%. Kinetic analysis shows that the leaching process fits the chemical reaction-controlled model.


Assuntos
Reciclagem , Silício , Silício/química , Compostos de Silício/química , Compostos Inorgânicos de Carbono/química , Dióxido de Silício/química , Cinética , Temperatura
2.
J Environ Manage ; 363: 121361, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38850924

RESUMO

Carbide slag (CS) is a kind of solid waste generated by the hydrolysis of calcium carbide for acetylene production. Its major component is Ca(OH)2, which shows great potential in CO2 mineralization to produce CaCO3. However, the types of impurities in CS and their mechanisms for inducing the morphological evolution of CaCO3 are still unclear. In this work, the influence of impurities in CS on the morphology evolution of CaCO3 was investigated. The following impurities were identified in the CS: Al2O3, MgO, Fe2O3, SiO2 and CaCO3. Ca(OH)2 was used to study the influence of impurities (Al2O3 and Fe2O3) on the evolution of CaCO3 morphology during CS carbonation. Calcite (CaCO3) was the carbonation product produced during CS carbonation under varying conditions. The morphology of calcite was changed from cubic to rod-shaped, with increasing solid-liquid ratios. Moreover, rod-shaped calcite was converted into irregular particles with increasing CO2 flow rate and stirring speed. Rod-shaped calcite (CaCO3) was formed by CS carbonation at a solid-liquid ratio of 10:100 under a stirring speed of 600 rpm and a CO2 flow rate of 200 ml/min; and spherical calcite was generated during Ca(OH)2 carbonation under the same conditions. Al2O3 impurities had negligible effects on spherical CaCO3 during Ca(OH)2 carbonation. In contrast, rod-shaped CaCO3 was generated by adding 0.13 wt% Fe2O3 particles, similar to the content of Fe2O3 in CS. Rod-shaped calcite was converted into particulate calcite with increasing Fe2O3 content. The surface wettability and surface negative charge of Fe2O3 appeared to be responsible for the formation of rod-shaped CaCO3. This study enhances our understanding and utilization of CS and CO2 reduction and the fabrication of high-value rod-shaped CaCO3.


Assuntos
Carbonato de Cálcio , Carbonato de Cálcio/química , Resíduos Sólidos , Dióxido de Carbono , Compostos Inorgânicos de Carbono/química , Acetileno/análogos & derivados
3.
Water Sci Technol ; 89(10): 2783-2795, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38822614

RESUMO

Photocatalytically active ceramic flat sheet membranes based on a nanostructured titanium dioxide (TiO2) coating were produced for photocatalytic water treatment. The nano-TiO2 layer was produced by a novel combination of magnetron sputtering of a thin titanium layer on silicon carbide (SiC) membranes, followed by electrochemical oxidation (anodization) and subsequent heat treatment (HT). Characterization by Raman spectra and field emission scanning electron microscopy proved the presence of a nanostructured anatase layer on the membranes. The influence of the titanium layer thickness on the TiO2 formation process and the photocatalytic properties were investigated using anodization curves, by using cyclovoltammetry measurements, and by quantifying the generated hydroxyl radicals (OH•) under UV-A irradiation in water. Promising photocatalytic activity and permeability of the nano-TiO2-coated membranes could be demonstrated. A titanium layer of at least 2 µm was necessary for significant photocatalytic effects. The membrane sample with a 10 µm Ti/TiO2 layer had the highest photocatalytic activity showing a formation rate of 1.26 × 10-6 mmol OH• s-1. Furthermore, the membranes were tested several times, and a decrease in radical formation was observed. Assuming that these can be attributed to adsorption processes of the reactants, initial experiments were carried out to reactivate the photocatalyzer.


Assuntos
Compostos Inorgânicos de Carbono , Radical Hidroxila , Membranas Artificiais , Compostos de Silício , Titânio , Purificação da Água , Titânio/química , Radical Hidroxila/química , Purificação da Água/métodos , Catálise , Compostos de Silício/química , Compostos Inorgânicos de Carbono/química , Técnicas Eletroquímicas , Nanoestruturas/química , Processos Fotoquímicos
4.
Am J Dent ; 37(2): 66-70, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38704848

RESUMO

PURPOSE: To evaluate the effect of different finishing and polishing systems on the surface roughness of a resin composite subjected to simulated saliva-, acid-, and enzyme-induced degradation. METHODS: 160 specimens (n= 40) were fabricated with Filtek Z350 XT nanofilled composite and analyzed for average surface roughness (Ra). The specimens were finished and polished using: AD - Al2O3-impreginated rubberized discs (medium, fine, and superfine grit, Sof-Lex); SD - silicon carbide and Al2O3-impregnated rubberized discs (coarse, medium and fine grit, Jiffy,); MB - 12- and 30-multiblade burs. The control group (CT) (n= 40) comprised specimens with a Mylar-strip-created surface. Specimens from each group were immersed in 1 mL of one of the degradation methods (n= 10): artificial saliva (ArS: pH 6.75), cariogenic challenge (CaC: pH 4.3), erosive challenge (ErC: 0.05M citric acid, pH 2.3) or enzymatic challenge (EzC: artificial saliva with 700 µg/mL of albumin, pH 6.75). The immersion period simulated a time frame of 180 days. Ra measurements were also performed at the post-polishing and post-degradation time points. The data were evaluated by three-way ANOVA for repeated measures and the Tukey tests. RESULTS: There was significant interaction between the finishing/polishing system and the degradation method (P= 0.001). AD presented the greatest smoothness, followed by SD. After degradation, CT, AD and SD groups became significantly rougher, but not the MB group, which presented no difference in roughness before or after degradation. CT and AD groups showed greater roughness in CaC, ErC and EzC than in ArS. The SD group showed no difference in roughness when the specimens were polished with CaC, EzC or ArS, but those treated with ErC had greater roughness. In the MB group, the lower roughness values were found after using CaC and EzC, while the higher values were found using ErC or ArS. CLINICAL SIGNIFICANCE: As far as degradation resistance of nanofilled composite to hydrolysis, bacterial and dietary acids and enzymatic reactions is concerned, restorations that had been finished and polished with Al2O3-impregnated discs had the smoothest surfaces.


Assuntos
Óxido de Alumínio , Resinas Compostas , Polimento Dentário , Saliva Artificial , Compostos de Silício , Propriedades de Superfície , Resinas Compostas/química , Polimento Dentário/métodos , Humanos , Saliva Artificial/química , Concentração de Íons de Hidrogênio , Óxido de Alumínio/química , Compostos de Silício/química , Compostos Inorgânicos de Carbono/química , Teste de Materiais , Nanocompostos/química , Ácido Cítrico/química , Saliva/enzimologia , Saliva/metabolismo , Saliva/química , Erosão Dentária , Borracha/química , Materiais Dentários/química
5.
J Dent ; 146: 105101, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38801940

RESUMO

OBJECTIVE: To evaluate the effect of polishing and layering thickness on the wear resistance of 3D-printed occlusal splint materials. METHODS: Specimens with 3 different layer thicknesses (50, 75, 100 µm) were produced in the form of a disc 3 mm thick using V-Print splint resin on a 3D-printer with digital light processing technology. (n = 16 for each thickness) All specimens were washed and cured according to the manufacturer's instructions. Half of the specimens of each layer thickness were polished with silicon carbide papers. All specimens were subjected to 120.000 cycles of a chewing simulator for 2-body wear tests. Before and after the wear test, the specimens were scanned with a laser scanner, and the images were overlaid using a 3D analysis program and the volume loss was calculated. The wear patterns of the specimens were examined under a scanning electron microscope. Statistical evaluation was performed using a Shapiro-Wilk test, 2-way ANOVA, 1-way ANOVA, and Tukey post hoc test (α = 0.05). RESULTS: While polishing had a significant effect (p = 0.003) on the wear volume of the occlusal splints, layer thickness (p = 0.105) and their interaction between polishing and layer thickness (p = 0.620) did not significantly affect the wear volume. Regardless of the polishing, the lowest mean wear was observed for D50 (0.064 mm3), followed by D75 (0.078 mm3), and D100 (0.096 mm3). However, a significant difference was observed only between polished D50 and unpolished D100. CONCLUSION: The polished 3D-printed occlusal splint resin showed higher wear resistance than the unpolished one, regardless of the layer thickness. CLINICAL SIGNIFICANCE: Since different layer thicknesses of 50 µm and greater had no effect on the wear resistance of the material, a layer thickness of 100 µm may be preferred for faster printing. However, polishing occlusal splints may reduce the amount of wear and improve clinical performance.


Assuntos
Polimento Dentário , Teste de Materiais , Microscopia Eletrônica de Varredura , Placas Oclusais , Impressão Tridimensional , Propriedades de Superfície , Polimento Dentário/métodos , Humanos , Compostos Inorgânicos de Carbono/química , Compostos de Silício/química , Desgaste de Restauração Dentária , Lasers , Materiais Dentários/química , Desenho Assistido por Computador , Mastigação/fisiologia
6.
Phys Chem Chem Phys ; 26(18): 14018-14036, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38683598

RESUMO

In this study, the potential of aluminum nitride (h-AlN), boron nitride (h-BN) and silicon carbide (h-SiC) nanosheets as the drug delivery systems (DDS) of isoniazid (INH) was scrutinized through density functional theory (DFT) and molecular dynamic (MD) simulations. We performed DFT periodic calculations on the geometry and electronic features of nanosheets adsorbed with INH by the DFT functional (DZP/GGA-PBE) employed in the SIESTA code. In the energetically favorable model, an oxygen atom of the C-O group of the INH molecule interacts with a Si atom of the h-SiC at 2.077 Å with an interaction energy of -1.361 eV. Charge transfer (CT) calculation by employing the Mulliken, Hirshfeld and Voronoi approaches reveals that the monolayers and drug molecules act as donors and acceptors, respectively. The density of states (DOS) calculations indicate that the HOMO-LUMO energy gap (HLG) of the h-SiC nanosheet declines significantly from 2.543 to 1.492 eV upon the adsorption of the INH molecule, which causes an electrical conductivity increase and then produces an electrical signal. The signal is linked to the existence of INH, demonstrating that h-SiC may be an appropriate sensor for INH sensing. The decrease in HLG for the interaction of INH and h-SiC is the uppermost (up to 41%) representing the uppermost sensitivity, whereas the sensitivity trend is σ(h-SiC) > σ(h-AlN) > σ(h-BN). Quantum theory of atoms in molecules (QTAIM) investigations is employed to scrutinize the nature of the INH/nanosheet interactions. The QTAIM analysis reveals that the interaction of the INH molecule and h-SiC has a partially covalent nature, while INH/h-AlN model electrostatic interaction occurs in the system and noncovalent and electrostatic interaction for the INH/h-BN model. Finally, the state-of-the-art DFT-MD simulations utilized in this study can mimic ambient conditions. The results obtained from the MD simulation show that it takes more time to bond the INH drug and h-SiC, and the INH/h-SiC system becomes stable. The results of the current research demonstrate the potential of h-SiC as a suitable sensor and drug delivery platform for INH drugs to remedy tuberculosis.


Assuntos
Compostos de Boro , Compostos Inorgânicos de Carbono , Teoria da Densidade Funcional , Isoniazida , Simulação de Dinâmica Molecular , Compostos de Silício , Isoniazida/química , Compostos de Silício/química , Compostos Inorgânicos de Carbono/química , Compostos de Boro/química , Sistemas de Liberação de Medicamentos , Nanoestruturas/química , Antituberculosos/química , Compostos de Nitrogênio/química , Portadores de Fármacos/química , Compostos de Alumínio
7.
Biomaterials ; 308: 122543, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38547834

RESUMO

Chronic implantation of intracortical microelectrode arrays (MEAs) capable of recording from individual neurons can be used for the development of brain-machine interfaces. However, these devices show reduced recording capabilities under chronic conditions due, at least in part, to the brain's foreign body response (FBR). This creates a need for MEAs that can minimize the FBR to possibly enable long-term recording. A potential approach to reduce the FBR is the use of MEAs with reduced cross-sectional geometries. Here, we fabricated 4-shank amorphous silicon carbide (a-SiC) MEAs and implanted them into the motor cortex of seven female Sprague-Dawley rats. Each a-SiC MEA shank was 8 µm thick by 20 µm wide and had sixteen sputtered iridium oxide film (SIROF) electrodes (4 per shank). A-SiC was chosen as the fabrication base for its high chemical stability, good electrical insulation properties, and amenability to thin film fabrication. Electrochemical analysis and neural recordings were performed weekly for 4 months. MEAs were characterized pre-implantation in buffered saline and in vivo using electrochemical impedance spectroscopy and cyclic voltammetry at 50 mV/s and 50,000 mV/s. Neural recordings were analyzed for single unit activity. At the end of the study, animals were sacrificed for immunohistochemical analysis. We observed statistically significant, but small, increases in 1 and 30 kHz impedance values and 50,000 mV/s charge storage capacity over the 16-week implantation period. Slow sweep 50 mV/s CV and 1 Hz impedance did not significantly change over time. Impedance values increased from 11.6 MΩ to 13.5 MΩ at 1 Hz, 1.2 MΩ-2.9 MΩ at 1 kHz, and 0.11 MΩ-0.13 MΩ at 30 kHz over 16 weeks. The median charge storage capacity of the implanted electrodes at 50 mV/s was 58.1 mC/cm2 on week 1 and 55.9 mC/cm2 on week 16, and at 50,000 mV/s, 4.27 mC/cm2 on week 1 and 5.93 mC/cm2 on week 16. Devices were able to record neural activity from 92% of all active channels at the beginning of the study, At the study endpoint, a-SiC devices were still recording single-unit activity on 51% of electrochemically active electrode channels. In addition, we observed that the signal-to-noise ratio experienced a small decline of -0.19 per week. We also classified observed units as fast and slow repolarizing based on the trough-to-peak time. Although the overall presence of single units declined, fast and slow repolarizing units declined at a similar rate. At recording electrode depth, immunohistochemistry showed minimal tissue response to the a-SiC devices, as indicated by statistically insignificant differences in activated glial cell response between implanted brains slices and contralateral sham slices at 150 µm away from the implant location, as evidenced by GFAP staining. NeuN staining revealed the presence of neuronal cell bodies close to the implantation site, again statistically not different from a contralateral sham slice. These results warrant further investigation of a-SiC MEAs for future long-term implantation neural recording studies.


Assuntos
Compostos Inorgânicos de Carbono , Eletrodos Implantados , Microeletrodos , Córtex Motor , Ratos Sprague-Dawley , Compostos de Silício , Animais , Compostos de Silício/química , Feminino , Córtex Motor/fisiologia , Córtex Motor/citologia , Compostos Inorgânicos de Carbono/química , Ratos , Neurônios/fisiologia
8.
Phys Med Biol ; 69(9)2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38530300

RESUMO

Objective.The successful implementation of FLASH radiotherapy in clinical settings, with typical dose rates >40 Gy s-1, requires accurate real-time dosimetry.Approach.Silicon carbide (SiC) p-n diode dosimeters designed for the stringent requirements of FLASH radiotherapy have been fabricated and characterized in an ultra-high pulse dose rate electron beam. The circular SiC PiN diodes were fabricated at IMB-CNM (CSIC) in 3µm epitaxial 4H-SiC. Their characterization was performed in PTB's ultra-high pulse dose rate reference electron beam. The SiC diode was operated without external bias voltage. The linearity of the diode response was investigated up to doses per pulse (DPP) of 11 Gy and pulse durations ranging from 3 to 0.5µs. Percentage depth dose measurements were performed in ultra-high dose per pulse conditions. The effect of the total accumulated dose of 20 MeV electrons in the SiC diode sensitivity was evaluated. The temperature dependence of the response of the SiC diode was measured in the range 19 °C-38 °C. The temporal response of the diode was compared to the time-resolved beam current during each electron beam pulse. A diamond prototype detector (flashDiamond) and Alanine measurements were used for reference dosimetry.Main results.The SiC diode response was independent both of DPP and of pulse dose rate up to at least 11 Gy per pulse and 4 MGy s-1, respectively, with tolerable deviation for relative dosimetry (<3%). When measuring the percentage depth dose under ultra-high dose rate conditions, the SiC diode performed comparably well to the reference flashDiamond. The sensitivity reduction after 100 kGy accumulated dose was <2%. The SiC diode was able to follow the temporal structure of the 20 MeV electron beam even for irregular pulse estructures. The measured temperature coefficient was (-0.079 ± 0.005)%/°C.Significance.The results of this study demonstrate for the first time the suitability of silicon carbide diodes for relative dosimetry in ultra-high dose rate pulsed electron beams up to a DPP of 11 Gy per pulse.


Assuntos
Compostos Inorgânicos de Carbono , Dosímetros de Radiação , Radiometria , Radiometria/métodos , Compostos de Silício , Elétrons
9.
PLoS One ; 19(3): e0295938, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38466758

RESUMO

In order to solve the problem that the skid resistance of concrete pavement in tunnel deteriorates rapidly, which is easy to cause traffic accidents, the anti-skid rapid elevation technology of surface treatment is proposed. Wear tests were used to investigate the effects of concrete surface roughness, properties of modified emulsified asphalt binder and anti-skid fine aggregate type on long-term skid resistance of treated surfaces. The results show that the four coarsening methods of fine milling, milling, grooving and brooming can improve the skid resistance of concrete, and the skid resistance durability of fine milling and milling is better. The adhesive property of modified emulsified asphalt is the best when the content of water-based epoxy resin is 20%. In different aggregates, the anti-skid effect is better when silicon carbide is used as anti-skid aggregate and the particle size is 0.6mm:0.3mm = 2:3. The method of fine milling of concrete surface + spraying epoxy emulsified asphalt + spreading silicon carbide can effectively improve the anti-skid performance of the original concrete pavement, and the feasibility of the scheme is verified by the test road. The research results have a good reference value for improving the skid resistance of tunnel concrete pavement.


Assuntos
Acidentes de Trânsito , Compostos Inorgânicos de Carbono , Hidrocarbonetos , Compostos de Silício , Tamanho da Partícula
10.
Nanotoxicology ; 18(2): 107-118, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38420713

RESUMO

To date, research on the toxicity and potential environmental impacts of nanomaterials has predominantly focused on relatively simple and single-component materials, whilst more complex nanomaterials are currently entering commercial stages. The current study aimed to assess the long-term and size-dependent (60 and 500 nm) toxicity of a novel core-shell nanostructure consisting of a SiC core and TiO2 shell (SiC/TiO2, 5, 25, and 50 mg L-1) to the common model organism Daphnia magna. These novel core-shell nanostructures can be categorized as advanced materials. Experiments were conducted under environmentally realistic feeding rations and in the presence of a range of concentrations of humic acid (0.5, 2, 5, and 10 mg L-1 TOC). The findings show that although effect concentrations of SiC/TiO2 were several orders of magnitude lower than the current reported environmental concentrations of more abundantly used nanomaterials, humic acid can exacerbate the toxicity of SiC/TiO2 by reducing aggregation and sedimentation rates. The EC50 values (mean ± standard error) based on nominal SiC/TiO2 concentrations for the 60 nm particles were 28.0 ± 11.5 mg L-1 (TOC 0.5 mg L-1), 21.1 ± 3.7 mg L-1 (TOC 2 mg L-1), 18.3 ± 5.4 mg L-1 (TOC 5 mg L-1), and 17.8 ± 2.4 mg L-1 (TOC 10 mg L-1). For the 500 nm particles, the EC50 values were 34.9 ± 16.5 mg L-1 (TOC 0.5 mg L-1), 24.8 ± 5.6 mg L-1 (TOC 2 mg L-1), 28.0 ± 10.0 mg L-1 (TOC 5 mg L-1), and 23.2 ± 4.1 mg L-1 (TOC 10 mg L-1). We argue that fate-driven phenomena are often neglected in effect assessments, whilst environmental factors such as the presence of humic acid may significantly influence the toxicity of nanomaterials.


Assuntos
Compostos Inorgânicos de Carbono , Daphnia , Substâncias Húmicas , Titânio , Titânio/toxicidade , Titânio/química , Substâncias Húmicas/análise , Daphnia/efeitos dos fármacos , Animais , Compostos Inorgânicos de Carbono/toxicidade , Compostos Inorgânicos de Carbono/química , Compostos de Silício/toxicidade , Compostos de Silício/química , Poluentes Químicos da Água/toxicidade , Poluentes Químicos da Água/química , Tamanho da Partícula , Nanopartículas/toxicidade , Nanopartículas/química , Daphnia magna
11.
ACS Appl Bio Mater ; 7(2): 892-908, 2024 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-38253516

RESUMO

In this study, we have synthesized a bioactive glass with composition 45SiO2-20Na2O-23CaO-6P2O5-2.5B2O3-1ZnO-2MgO-0.5CaF2 (wt %). Further, it has been incorporated with 0.4 wt % iron carbide nanoparticles to prepare magnetic bioactive glass (MBG) with good heat generation capability for potential applications in magnetic field-assisted hyperthermia. The MBG scaffolds have been fabricated using extrusion-based additive manufacturing by mixing MBG powder with 25% Pluronic F-127 solution as the binder. The saturation magnetization of iron carbide nanoparticles in the bioactive glass matrix has been found to be 80 emu/g. The morphological analysis (pore size distribution, porosity, open pore network modeling, tortuosity, and pore interconnectivity) was done using an in-house developed methodology that revealed the suitability of the scaffolds for bone tissue engineering. The compressive strength (14.3 ± 1.6 MPa) of the MBG scaffold was within the range of trabecular bone. The in vitro test using simulated body fluid (SBF) showed the formation of apatite indicating the bioactive nature of scaffolds. Further, the drug delivery behaviors of uncoated and polycaprolactone (PCL) coated MBG scaffolds have been evaluated by loading an anticancer drug (Mitomycin C) onto the scaffolds. While the uncoated scaffold demonstrated the drug's burst release for the initial 80 h, the PCL-coated scaffold showed the gradual release of the drug. These results demonstrate the potential of the proposed MBG for bone tissue engineering and drug delivery applications.


Assuntos
Compostos Inorgânicos de Carbono , Compostos de Ferro , Engenharia Tecidual , Alicerces Teciduais , Engenharia Tecidual/métodos , Vidro , Osso e Ossos
12.
Adv Sci (Weinh) ; 11(8): e2305459, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37988692

RESUMO

Magnetic nanomaterials have played a crucial role in promoting the application of nanotechnology in the biomedical field. Although conventional magnetic nanomaterials such as iron oxide nanoparticles (NPs) are used as biosensors, drug delivery vehicles, diagnostic and treatment agents for several diseases, the persistent pursuit of high-performance technologies has prompted researchers to continuously develop new types of magnetic nanomaterials such as iron carbide NPs. Considering their potential application in biomedicine, magnetic NPs responsive to exogenous or endogenous stimuli are developed, thereby enhancing their applicability in more complex versatile scenarios. In this review, the synthesis and surface modification of magnetic NPs are focused, particularly iron carbide NPs. Subsequently, exogenous and endogenous stimuli-responsive magnetic NP-based theranostic platforms are introduced, particularly focusing on nanozyme-based technologies and magnetic NP-mediated immunotherapy, which are emerging stimuli-responsive treatments. Finally, the challenges and perspectives of magnetic NPs to accelerate future research in this field are discussed.


Assuntos
Compostos Inorgânicos de Carbono , Compostos de Ferro , Nanopartículas de Magnetita , Medicina de Precisão , Nanopartículas de Magnetita/uso terapêutico , Sistemas de Liberação de Medicamentos , Magnetismo
13.
Macromol Rapid Commun ; 45(5): e2300602, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38052160

RESUMO

Enhancing the piezoresistivity of polymer-derived silicon oxycarbide ceramics (SiOCPDC ) is of great interest in the advancement of highly sensitive pressure/load sensor technology for use in harsh and extreme working conditions. However, a facile, low cost, and scalable approach to fabricate highly piezoresistive SiOCPDC below 1400 °C still remains a great challenge. Here, the fabrication and enhancement of piezoresistive properties of SiOCPDC reinforced with ß-SiC nanopowders (SiCNP ) through masked stereolithography-based 3D-printing and subsequent pyrolysis at 1100 °C are demonstrated. The presence of free carbon in SiCNP augments high piezoresistivity in the fabricated SiCNP -SiOCPDC composites even at lower pyrolysis temperatures. A gauge factor (GF) in the range of 4385-5630 and 6129-8987 with 0.25 and 0.50 wt% of SiCNP , respectively is demonstrated, for an applied pressure range of 0.5-5 MPa at ambient working conditions. The reported GF is significantly higher compared to those of any existing SiOCPDC materials. This rapid and facile fabrication route with significantly enhanced piezoresistive properties makes the 3D-printed SiCNP -SiOCPDC composite a promising high-performance material for the detection of pressure/load in demanding applications. Also, the overall robustness in mechanical properties and load-bearing capability ensures its long-term stability and makes it suitable for challenging and severe environment applications.


Assuntos
Compostos Inorgânicos de Carbono , Impressão Tridimensional , Compostos de Silício , Estereolitografia , Cerâmica , Polímeros
14.
Adv Mater ; 36(9): e2307006, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37924225

RESUMO

The ferroptosis pathway is recognized as an essential strategy for tumor treatment. However, killing tumor cells in deep tumor regions with ferroptosis agents is still challenging because of distinct size requirements for intratumoral accumulation and deep tumor penetration. Herein, intelligent nanocapsules with size-switchable capability that responds to acid/hyperthermia stimulation to achieve deep tumor ferroptosis are developed. These nanocapsules are constructed using poly(lactic-co-glycolic) acid and Pluronic F127 as carrier materials, with Au-Fe2 C Janus nanoparticles serving as photothermal and ferroptosis agents, and sorafenib (SRF) as the ferroptosis enhancer. The PFP@Au-Fe2 C-SRF nanocapsules, designed with an appropriate size, exhibit superior intratumoral accumulation compared to free Au-Fe2 C nanoparticles, as evidenced by photoacoustic and magnetic resonance imaging. These nanocapsules can degrade within the acidic tumor microenvironment when subjected to laser irradiation, releasing free Au-Fe2 C nanoparticles. This enables them to penetrate deep into tumor regions and disrupt intracellular redox balance. Under the guidance of imaging, these PFP@Au-Fe2 C-SRF nanocapsules effectively inhibit tumor growth when exposed to laser irradiation, capitalizing on the synergistic photothermal and ferroptosis effects. This study presents an intelligent formulation based on iron carbide for achieving deep tumor ferroptosis through size-switchable cascade delivery, thereby advancing the comprehension of ferroptosis in the context of tumor theranostics.


Assuntos
Compostos Inorgânicos de Carbono , Ferroptose , Hipertermia Induzida , Compostos de Ferro , Nanocápsulas , Nanopartículas , Neoplasias , Humanos , Linhagem Celular Tumoral , Neoplasias/terapia , Sorafenibe , Hipertermia/terapia , Hipertermia Induzida/métodos , Microambiente Tumoral
15.
Environ Sci Pollut Res Int ; 30(18): 52141-52156, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36823461

RESUMO

The "double-carbon" policy is a new opportunity for the transformation of China's production sector. With steady economic growth, each province has proposed specific policies aimed at cleaner production. However, the interactions between regions and the complex linkages between industries have hindered the implementation of the "double-carbon" policy. In order to address this issue, we introduced a complex network framework with multiple industries at a national level. The framework aimed to clarify whether there is fluctuation diffusion in China's multi-province multi-industry carbon emission system, to identify key industries and regions, and to answer the question of "who" is the most effective in governance. The results showed that the fluctuations of industrial carbon emissions had a cross-regional diffusion effect in China indeed. The diffusion capacity of industry fluctuation depends on whether the industry is located at a "hub" position in the network. Hub industries with strong capacity can spread the carbon emission fluctuation of themselves and upstream or downstream industries to the whole country through regional interactions. This characteristic of the hub industry should be taken into account in governance to maximize the effectiveness of emission reduction. Shandong and Inner Mongolia, as important provinces for the production of intermediate products and energy chemicals in China, had a greater role to play in global carbon supply push from their hub industries than in the demand pull. The pulling capacity of Beijing-Tianjin-Hebei region to the national carbon demand side was greater than that of Yangtze River Delta and Pearl River Delta. These findings might have implications for environmental and economic policymaking, particularly with regard to cross-provincial coordinated systemic solutions and policy anchors for synergy with industries.


Assuntos
Compostos Inorgânicos de Carbono , Carbono , Desenvolvimento Econômico , Monitoramento Ambiental , Política Ambiental , Indústrias , Humanos , Pequim , Carbono/análise , Compostos Inorgânicos de Carbono/análise , Dióxido de Carbono/análise , China , Indústrias/organização & administração , Indústrias/normas , Monitoramento Ambiental/métodos , Monitoramento Ambiental/normas
16.
Environ Sci Pollut Res Int ; 30(18): 51861-51874, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36820976

RESUMO

Against achieving carbon peaking by 2030 and carbon neutrality by 2060 context in China, the new energy demonstration city policy (NEDCP) has a crucial function to perform in promoting resource utilization efficiency, building the green development policy system, and facilitating carbon emission reduction. However, existing research has rarely investigated the contribution of NEDCP on carbon reduction. To investigate the policy effect of NEDCP, the differences-in-differences (DID) model is introduced to quantify the influence of NEDCP on carbon reduction, taking a statistical sample of 285 Chinese cities over the period 2005-2017 on the basis of exploring the intrinsic mechanism of NEDCP on carbon emissions. The statistical results reveal that NEDCP significantly inhibits carbon emissions. NEDCP's dampening impact on carbon reduction is more pronounced in the eastern area but not in other areas. City size and resource endowment heterogeneity results suggest that NEDCP significantly inhibits the output of carbon emissions in non-resource-based and large cities but insignificantly in resource-based and small- and medium-sized cities. Finally, we conclude that policy-makers should not only broaden the scope of NEDCP implementation continuously but also design relevant policy combination tools following the basic characteristics of each city to provide institutional guarantees for achieving carbon emission reduction.


Assuntos
Compostos Inorgânicos de Carbono , Planejamento de Cidades , Conservação dos Recursos Naturais , Monitoramento Ambiental , Política Pública , Carbono , Compostos Inorgânicos de Carbono/efeitos adversos , Compostos Inorgânicos de Carbono/análise , Dióxido de Carbono , China , Cidades , Desenvolvimento Econômico , Política Ambiental , Monitoramento Ambiental/métodos
17.
PLoS One ; 18(1): e0277331, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36638108

RESUMO

Most silicon carbide (SiC) MOSFET models are application-specific. These are already defined by the manufacturers and their parameters are mostly partially accessible due to restrictions. The desired characteristic of any SiC model becomes highly important if an individual wants to visualize the impact of changing intrinsic parameters as well. Also, it requires a model prior knowledge to vary these parameters accordingly. This paper proposes the parameter extraction and its selection for Silicon Carbide (SiC) power N-MOSFET model in a unique way. The extracted parameters are verified through practical implementation with a small-scale high power DC-DC 5 to 2.5 output voltage buck converter using both hardware and software emphasis. The parameters extracted using the proposed method are also tested to verify the static and dynamic characteristics of SiC MOSFET. These parameters include intrinsic, junction and overlapping capacitance. The parameters thus extracted for the SiC MOSFET are analyzed by device performance. This includes input, output transfer characteristics and transient delays under different temperature conditions and loading capabilities. The simulation and experimental results show that the parameters are highly accurate. With its development, researchers will be able to simulate and test any change in intrinsic parameters along with circuit emphasis.


Assuntos
Fontes de Energia Elétrica , Software , Simulação por Computador , Compostos Inorgânicos de Carbono
18.
Molecules ; 27(18)2022 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-36144499

RESUMO

Protein corona composition and precise physiological understanding of differentially expressed proteins are key for identifying disease biomarkers. In this report, we presented a distinctive quantitative proteomics table of molecular cell signaling differentially expressed proteins of corona that formed on iron carbide nanoparticles (NPs). High-performance liquid chromatography/electrospray ionization coupled with ion trap mass analyzer (HPLC/ESI-Orbitrap) and MASCOT helped quantify 142 differentially expressed proteins. Among these proteins, 104 proteins showed upregulated behavior and 38 proteins were downregulated with respect to the control, whereas 48, 32 and 24 proteins were upregulated and 8, 9 and 21 were downregulated CW (control with unmodified NPs), CY (control with modified NPs) and WY (modified and unmodified NPs), respectively. These proteins were further categorized on behalf of their regularity, locality, molecular functionality and molecular masses using gene ontology (GO). A STRING analysis was used to target the specific range of proteins involved in metabolic pathways and molecular processing in different kinds of binding functionalities, such as RNA, DNA, ATP, ADP, GTP, GDP and calcium ion bindings. Thus, this study will help develop efficient protocols for the identification of latent biomarkers in early disease detection using protein fingerprints.


Assuntos
Nanopartículas , Coroa de Proteína , Difosfato de Adenosina , Trifosfato de Adenosina , Cálcio , Compostos Inorgânicos de Carbono , Análise por Conglomerados , Guanosina Trifosfato , Compostos de Ferro , Nanopartículas/química , Coroa de Proteína/química , Proteínas/metabolismo , Proteômica/métodos , RNA
19.
Proc Natl Acad Sci U S A ; 119(33): e2203287119, 2022 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-35939711

RESUMO

Electrical neuron stimulation holds promise for treating chronic neurological disorders, including spinal cord injury, epilepsy, and Parkinson's disease. The implementation of ultrathin, flexible electrodes that can offer noninvasive attachment to soft neural tissues is a breakthrough for timely, continuous, programable, and spatial stimulations. With strict flexibility requirements in neural implanted stimulations, the use of conventional thick and bulky packages is no longer applicable, posing major technical issues such as short device lifetime and long-term stability. We introduce herein a concept of long-lived flexible neural electrodes using silicon carbide (SiC) nanomembranes as a faradic interface and thermal oxide thin films as an electrical barrier layer. The SiC nanomembranes were developed using a chemical vapor deposition (CVD) process at the wafer level, and thermal oxide was grown using a high-quality wet oxidation technique. The proposed material developments are highly scalable and compatible with MEMS technologies, facilitating the mass production of long-lived implanted bioelectrodes. Our experimental results showed excellent stability of the SiC/silicon dioxide (SiO2) bioelectronic system that can potentially last for several decades with well-maintained electronic properties in biofluid environments. We demonstrated the capability of the proposed material system for peripheral nerve stimulation in an animal model, showing muscle contraction responses comparable to those of a standard non-implanted nerve stimulation device. The design concept, scalable fabrication approach, and multimodal functionalities of SiC/SiO2 flexible electronics offer an exciting possibility for fundamental neuroscience studies, as well as for neural stimulation-based therapies.


Assuntos
Terapia por Estimulação Elétrica , Neuroestimuladores Implantáveis , Nanoestruturas , Semicondutores , Compostos Inorgânicos de Carbono/química , Terapia por Estimulação Elétrica/instrumentação , Membranas Artificiais , Compostos de Silício/química , Dióxido de Silício/química
20.
ACS Nano ; 16(7): 10890-10903, 2022 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-35816450

RESUMO

The integration of micro- and nanoelectronics into or onto biomedical devices can facilitate advanced diagnostics and treatments of digestive disorders, cardiovascular diseases, and cancers. Recent developments in gastrointestinal endoscopy and balloon catheter technologies introduce promising paths for minimally invasive surgeries to treat these diseases. However, current therapeutic endoscopy systems fail to meet requirements in multifunctionality, biocompatibility, and safety, particularly when integrated with bioelectronic devices. Here, we report materials, device designs, and assembly schemes for transparent and stable cubic silicon carbide (3C-SiC)-based bioelectronic systems that facilitate tissue ablation, with the capability for integration onto the tips of endoscopes. The excellent optical transparency of SiC-on-glass (SoG) allows for direct observation of areas of interest, with superior electronic functionalities that enable multiple biological sensing and stimulation capabilities to assist in electrical-based ablation procedures. Experimental studies on phantom, vegetable, and animal tissues demonstrated relatively short treatment times and low electric field required for effective lesion removal using our SoG bioelectronic system. In vivo experiments on an animal model were conducted to explore the versatility of SoG electrodes for peripheral nerve stimulation, showing an exciting possibility for the therapy of neural disorders through electrical excitation. The multifunctional features of SoG integrated devices indicate their high potential for minimally invasive, cost-effective, and outcome-enhanced surgical tools, across a wide range of biomedical applications.


Assuntos
Compostos Inorgânicos de Carbono , Compostos de Silício , Animais , Eletrônica , Eletrodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...