Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.225
Filtrar
1.
PLoS One ; 19(8): e0306367, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39133713

RESUMO

OBJECTIVE: This systematic review aims to evaluate the potential benefits and underlying mechanisms of combining SDF with light curing, based on available studies. MATERIALS AND METHODS: A systematic search of publications was conducted with the keywords "silver diamine fluoride" or "silver fluoride" and "dental light curing," "LED curing," "dental laser," and "dental polymerization" in 4 databases: PubMed, EBSCO, Scopus, and Google Scholar to identify English-language articles published up to March 2023. Duplicate publications were deleted. Two reviewers screened the titles and abstracts and excluded irrelevant publications. The full text of the remaining publications was retrieved. Studies investigating the effect of light-curing on SDF-treated carious lesions were included. RESULTS: The 175 publications initially found included 5 laboratory studies investigating the effects of light curing on 38% SDF-treated dentine carious lesions, but no clinical study was found. Four of these studies were conducted on extracted primary teeth, and one was on extracted permanent teeth. SDF with light curing increased microhardness (n = 3, p < .05) showed a higher mineral density (n = 1, p < .041) and had more silver ion precipitation in infected dentine (n = 1, p < .016) compared to SDF without light curing. Moreover, no significant differences in the antibacterial activity were observed between SDF with light curing and SDF alone (n = 1, p > .05). CONCLUSION: Drawing from the limited number of laboratory studies, incorporating light curing subsequent to the SDF application yields potential favorable outcomes that include augmented microhardness, elevated mineral density, and heightened silver ion precipitation within infected dentine. Future clinical research is required to confirm or refute the benefit of light curing on SDF-treated carious lesions.


Assuntos
Cárie Dentária , Fluoretos Tópicos , Compostos de Amônio Quaternário , Compostos de Prata , Compostos de Prata/farmacologia , Compostos de Prata/uso terapêutico , Cárie Dentária/prevenção & controle , Humanos , Compostos de Amônio Quaternário/farmacologia , Compostos de Amônio Quaternário/uso terapêutico , Fluoretos Tópicos/uso terapêutico , Lâmpadas de Polimerização Dentária , Cariostáticos/uso terapêutico
2.
Pediatr Dent ; 46(4): 271-276, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39123321

RESUMO

Purpose: To evaluate whether reduced curing performance due to compromised light tip placement can be mitigated by bulk-fill composite and/or high-intensity curing light. Methods: Plastic discs with 2.5-mm deep cavities were filled with a conventional (Mosaic™) or bulk-fill (Tetric® PowerFill) composite and cured with a BluePhase® PowerCure curing light at normal and high-power settings, with light tip placement at distance and/or 45 degree angle. Curing time and irradiance were three, five, or 10 seconds at 1,200, 2,000, or 3,000 mW/cm2 (10 samples). After 24 hours, Vickers hardness on top and bottom surfaces was measured and analyzed using analysis of variance and pairwise comparisons (α<0.05). Results: All top surfaces had higher hardness than bottom surfaces. Cure (bottom-to-top hardness ratio) was significantly affected by material, distance/angle, and curing regimen (P<0.001), and generally decreased when tip distance and angle increased. Bottom-to-top hardness ratios of bulk-fill composite (0.42 to 0.66) were significantly higher than those of conventional composite (0.20 to 0.31). High-power curing significantly increased bulk-fill's curing performance as it was specifically formulated for this curing light. Conclusions: Increased light tip distance and angle compromised composite curing. Bulk-fill composite cured better at the bottom of the restoration than conventional composite regardless of light tip distance/angle. High-power light curing improved curing performance only in bulk-fill composite. Nevertheless, due to low bottom-to-top ratios (0.20 to 0.66) across all samples, even under ideal light tip placement, both composites should be cured in increments of less than 2.5 mm.


Assuntos
Resinas Compostas , Lâmpadas de Polimerização Dentária , Dureza , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Resinas Compostas/química , Resinas Compostas/efeitos da radiação , Cura Luminosa de Adesivos Dentários/métodos , Propriedades de Superfície , Humanos , Polimerização , Materiais Dentários/química
3.
Gen Dent ; 72(5): 49-53, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39151082

RESUMO

This in vitro study evaluated the influence of radiant exposure and material shade on the degree of conversion (DC) and microhardness of a resin-based composite (RBC). Sixty-four RBC specimens in shades A1E (enamel) and A4D (dentin) were light cured at a calibrated exitance of 1000 mW/cm2 for 5, 10, 15, or 20 seconds, resulting in radiant exposure levels of 5, 10, 15, or 20 J/cm2. The DC was determined using Fourier-transform infrared spectroscopy (n = 3 per shade per exposure level). The Knoop hardness number (KHN) was measured on the top and bottom surfaces of each specimen (n = 5 per shade per exposure level). Data were analyzed using 2- and 3-way analyses of variance and post hoc Tukey tests (α = 0.05). The RBC shade did not affect the DC (P = 0.860), and the lowest DC values were achieved with an exposure level of 5 J/cm2 (P < 0.001). The shade did not affect the KHN on the top surface, but the radiant exposure level did, with the application of 5 J/cm2 resulting in significantly lower values (P < 0.05). For the bottom surface, shade A1E showed significantly higher KHN values than A4D (P < 0.001). An increase in the radiant exposure led to increased DC and KHN for both shades of RBC until reaching a saturation point of 10 J/cm2 for A1E and the top surface of A4D. The darker and more opaque shade was not adequately polymerized at a 2-mm depth, even when the highest radiant exposure level was applied.


Assuntos
Resinas Compostas , Dureza , Teste de Materiais , Resinas Compostas/química , Resinas Compostas/uso terapêutico , Espectroscopia de Infravermelho com Transformada de Fourier , Cor , Humanos , Polimerização , Propriedades de Superfície , Lâmpadas de Polimerização Dentária , Técnicas In Vitro , Materiais Dentários/química , Cura Luminosa de Adesivos Dentários/métodos
4.
Clin Oral Investig ; 28(8): 463, 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39090476

RESUMO

OBJECTIVES: The first aim of this study was to determine whether there is a difference in degree of conversion (DC) of touch-cure cements polymerized by self-curing with adhesive or dual-curing under reduced light. The second aim was to compare interfacial adaptation of zirconia restoration cemented using touch-cure cements self-cured or dual-cured by reduced light. METHODS: The DC of touch-cure resin cements with adhesive was measured continuously using Fourier transform infrared spectrometry. Experimental groups differed depending on touch-cure cement. Each group had three subgroups of polymerization method. For subgroup 1, the DC was measured by self-curing. For subgroups 2 and 3, the DCs were measured by dual-curing with reduced light penetrating 3 mm and 1 mm zirconia blocks, respectively. For interfacial adaptation evaluation, Class I cavity was prepared on an extracted third molar, and zirconia restoration was fabricated. The restoration was cemented using the same cement. Groups and subgroups for interfacial adaptation were the same as those of the DC measurement. After thermo-cycling, interfacial adaptation at the tooth-restoration interface was evaluated using swept-source optical coherence tomography imaging. RESULTS: The DC of touch-cure cement differed depending on the measurement time, resin cement, and polymerization method (p < 0.05). Interfacial adaptation was different depending on the resin cement and polymerization method (p < 0.05). CONCLUSION: For touch-cure cement, light-curing with higher irradiance presented a higher DC and superior interfacial adaptation than light-curing with lower irradiance or self-curing. CLINICAL RELEVANCE: Although some adhesives accelerate the self-curing of touch-cure cement, light-curing for touch-cure cement is necessary for zirconia cementation.


Assuntos
Teste de Materiais , Polimerização , Cimentos de Resina , Zircônio , Cimentos de Resina/química , Zircônio/química , Espectroscopia de Infravermelho com Transformada de Fourier , Autocura de Resinas Dentárias , Lâmpadas de Polimerização Dentária , Cura Luminosa de Adesivos Dentários , Propriedades de Superfície , Técnicas In Vitro , Humanos , Dente Serotino , Restauração Dentária Permanente/métodos
5.
Oper Dent ; 49(4): 421-431, 2024 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-38978305

RESUMO

OBJECTIVES: This study evaluated the depth of cure (DoC) of eight resin-based composites (RBCs) photocured using one multipeak light-curing unit (LCU) on the standard output setting for the manufacturer's RBC recommended exposure time and at a higher irradiance for 3 seconds. METHODS: Three conventional RBCs: Tetric EvoCeram (Evo), Tetric N-Ceram (Cer), Tetric Prime (Pri); and five bulk-fill: Tetric N-Ceram Bulk Fill (CerBF), Opus Bulk Fill APS (OpusBF), Opus Bulk Fill Flow APS (OpusF), Tetric PowerFill (PFill) and Tetric PowerFlow (PFlow) were examined. Only PFill and PFlow are formulated to be photocured in 3 seconds. The RBCs were packed into a metal mold and photocured using a Bluephase PowerCure LCU for the RBC manufacturer's recommended exposure time on the standard mode and using the 3-second high irradiance mode. After photocuring, the specimens were immersed in a solvent for 1 hour. The length of the remaining RBC was measured and divided by 2. Data were analyzed using two-way analysis of variance (ANOVA) followed by the Tukey post hoc multiple comparison test (α=0.05). RESULTS: There was no significant difference in the DoC values for PFill and PFlow when photocured using the 3-second high irradiance protocol compared to the lower irradiance standard mode protocol. All other RBCs had significantly lower DoC values (p<0.001) when photocured off-label using the 3-second high irradiance mode. CONCLUSION: Of the eight RBCs tested, only PFill and PFlow achieved the same DoC when the high irradiance 3-second curing method was used compared to when their longer lower irradiance protocol was used.


Assuntos
Resinas Compostas , Lâmpadas de Polimerização Dentária , Teste de Materiais , Resinas Compostas/uso terapêutico , Humanos , Fatores de Tempo , Polimerização , Cura Luminosa de Adesivos Dentários/métodos , Materiais Dentários/uso terapêutico , Materiais Dentários/química , Metacrilatos , Propriedades de Superfície
6.
Dent Mater J ; 43(4): 546-551, 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-38987204

RESUMO

Experimental light-curing pattern resins were fabricated to produce pattern resin materials with adequate dimensional stability. The light-curing pattern resins consisted of poly(n-butyl methacrylate) or poly(iso-butyl methacrylate) (PiBMA) polymers and methacrylate monomers. The physical properties, amount of residual ash after burning, Vickers hardness, flexural strength, and volumetric polymerization shrinkage of each material were determined. The data obtained for the prepared resins were compared with those of a commercially available pattern resin, Palavit G (PG). A lower amount of residual ash was observed for some of the prepared resins than for PG. The Vickers hardness and flexural strength values of all experimental resins were lower than those of PG. The volumetric polymerization shrinkage of all the experimental resins based on PiBMA was lower than that of PG. These results suggest that acrylic light-curing resin materials based on PiBMA may be useful for patterning and indexing during soldering.


Assuntos
Resistência à Flexão , Dureza , Teste de Materiais , Metacrilatos , Polimerização , Propriedades de Superfície , Metacrilatos/química , Cura Luminosa de Adesivos Dentários , Resinas Compostas/química , Resinas Compostas/efeitos da radiação , Lâmpadas de Polimerização Dentária , Resinas Acrílicas/química
7.
J Oral Sci ; 66(3): 182-188, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39010166

RESUMO

PURPOSE: To evaluate the influence of the polymerization distance of monowave and polywave light curing units (LCUs) on the measured irradiance relative to the value reported by the manufacturer in relation to the physical properties of resin-based composites (RBCs). METHODS: Four LCUs were used: one monowave and three polywave. The irradiance was measured with a digital radiometer. Depth of cure (DC) and flexural strength (FS) tests were performed according to ISO 4049:2019 at polymerization distances of 0 mm and 5 mm. RESULTS: The irradiance of all LCUs was higher than that reported by the manufacturer (>25-64%). The irradiance of the four LCUs was reduced when polymerization was performed at between 0 to 5 mm (paired t-test, P < 0.001). The DC at 0 mm was similar in all groups but was significantly decreased at 5 mm distance (ANOVA P < 0.001). FS showed differences among the LCUs at 0 mm (ANOVA P < 0.001) and was affected by the polymerization distance. The elastic modulus was unaffected by the LCU used or the distance (ANOVA P > 0.001). CONCLUSIONS: The LCU must be positioned as near as possible to RBCs during the polymerization process, as increased distance negatively affects the depth of cure and flexural strength.


Assuntos
Resinas Compostas , Lâmpadas de Polimerização Dentária , Polimerização , Resinas Compostas/química , Teste de Materiais , Resistência à Flexão , Módulo de Elasticidade
8.
BMC Oral Health ; 24(1): 865, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39080607

RESUMO

BACKGROUND: Recent studies have reported the inhomogeneity in the light emitted by dental light-curing units (LCUs). It is essential to understand how this uneven light distribution affects the physical properties of resin-based composites (RBCs) at various points across their surfaces. This study aimed to evaluate the effect of LCU beam's inhomogeneity on the microhardness of RBCs with different shades and thicknesses. METHODS: Four body (A1B, A2B, A3B, and A4B), one dentin (A3D), and one enamel shade (A3E) of RBC (Filtek Z350 XT) were examined. The specimens were fabricated in four thicknesses (1, 2, 3, and 4 mm) and subjected to a 40-second light-curing. Vickers microhardness testing was performed at the center point, and 3 mm left and right from the center at the bottom surface of each sample. The LCU beam profile was characterized using a beam profiler, while irradiance after specimen passage was measured using a spectrometer. One-way analysis of variance (ANOVA) and Tukey's post-hoc tests were used to analyze the effects of shades and thicknesses on irradiance and microhardness, respectively. One-way repeated-measures ANOVA was used to compare the microhardness across different points. Pearson's correlation analysis examined the relationship between irradiance and microhardness. RESULTS: The beam profile of LCU revealed inhomogeneous light distribution. Light irradiance was decreased with both the increase in thickness and darker shade of the specimens (p < 0.05). Microhardness was found to decline with an increase in sample thickness (p < 0.05), and was consistently higher at the center point compared to the periphery, particularly in thicker (3 and 4 mm) and darker shades (A3B, A4B, and A3D). A positive correlation was found between the irradiance and microhardness across all evaluated points (p < 0.05). CONCLUSIONS: Inhomogeneous light emission from LCU significantly influences the microhardness of RBC samples, depending on the thicknesses and shades. The findings underline the importance of considering LCU beam inhomogeneity in clinical settings to ensure optimal polymerization of RBC.


Assuntos
Cor , Resinas Compostas , Lâmpadas de Polimerização Dentária , Dureza , Teste de Materiais , Resinas Compostas/efeitos da radiação , Resinas Compostas/química , Humanos , Propriedades de Superfície , Cura Luminosa de Adesivos Dentários/métodos , Esmalte Dentário/efeitos da radiação , Dentina/efeitos da radiação , Materiais Dentários/efeitos da radiação , Materiais Dentários/química , Polimerização , Luz
9.
Dent Mater ; 40(8): 1208-1215, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38851964

RESUMO

OBJECTIVES: To investigate a near-infrared-to-blue luminescence upconversion curing method for polymerizing resin cements under zirconia discs. METHODS: Lava zirconia discs of different thicknesses (0.5-2.0 mm) were manufactured. First, the transmittances of the NIR and two blue lights (BLs) (LED and halogen lights) through these discs were measured. Second, NaYF4:Yb3+/Tm3+ upconversion phosphor (UP) powder was milled into 0.5-µm particle sizes. A light-curable resin cement VariolinkII base was chosen as the control (UP0), and an experimental cement (UP5) was prepared by adding 5 % UPs. These two cements were examined using multiphoton excitation microscopy for particle distribution. UP5 and UP0 were polymerized with or without zirconia shielding then subjected to a microhardness test. A multifold analysis was performed to examine the effects of zirconia thickness, curing protocols (pure BL or combined BL and NIR curing), and cement type. RESULTS: The transmittance of NIR was superior to that of BL through zirconia discs of all thicknesses. UP particles were homogeneously distributed in UP5 and emitted blue luminescence under 980-nm NIR excitation. UP5 showed higher microhardness values than UP0 under any curing protocol or zirconia shielding condition. The combination of 20-s BL and 40-s NIR curing yielded the highest microhardness in uncovered UP5. However, combining 40-s BL and 20-s NIR curing surpassed the other groups when the zirconia discs were thicker than 0.5 mm. SIGNIFICANCE: NIR exhibits higher transmission through zirconia than BL. UP particles work as strengthen fillers and photosensitizers in cements. NIR upconversion curing could be a new strategy for polymerizing resin cements under thick zirconia restorations.


Assuntos
Teste de Materiais , Polimerização , Cimentos de Resina , Zircônio , Zircônio/química , Cimentos de Resina/química , Luminescência , Dureza , Raios Infravermelhos , Cura Luminosa de Adesivos Dentários , Lâmpadas de Polimerização Dentária , Tamanho da Partícula , Propriedades de Superfície
10.
Dent Mater ; 40(8): 1244-1251, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38871527

RESUMO

OBJECTIVE: Polymerization shrinkage poses a significant challenge in dental resin composites. The objective of this study is to introduce spiroorthocarbonate monomer 3,9-dimethylene-1,3,5,7-tetraoxa-spiro[5,5]undecane (BMSOC) and epoxy resin monomer 3,4-epoxycyclohexylmethyl-3,4-epoxycyclohexane carboxylate (ECHM-ECHC) into bisphenol-S-bis(3-methacrylato-2-hydroxy propyl)ether (BisS-GMA) based resin composites to develop composites with reduced shrinkage properties. METHODS: BMSOC and BisS-GMA were synthesized and thoroughly mixed with ECHM-ECHC, followed by inorganic fillers and photoinitiators. Based on the composition of the resin matrix, five groups of experimental composites were prepared, with traditional bisphenol A-dimethacrylate glycidyl ester (Bis-GMA)/triethylene glycol dimethacrylate (TEGDMA) based composite serving as the control. The polymerization properties, including degree of conversion (DC) and polymerization shrinkage (PS), as well as marginal microleakage, wettability, flexural strength (FS), flexural modulus (FM), and biocompatibility were evaluated. RESULTS: The results demonstrated that compared with the control group, the PS of BisS-GMA based composites containing BMSOC and ECHM-ECHC were significantly reduced (P < 0.05), and the lowest PS (0.96 ± 0.08 %) was observed when the ratio of BisS-GMA: (Epoxy + BMSOC) was 4:6. Additionally, the experimental composites also exhibited improved DC, minimal microleakage, low hydrophilicity, enhanced mechanical properties, qualified in vivo biocompatibility, and slight/moderate in vitro biocompatibility. SIGNIFICANCE: The resin composites incorporating multiple modified low-shrink monomers are promising for dental applications to prevent various clinical problems caused by PS and extend restoration longevity.


Assuntos
Resinas Compostas , Teste de Materiais , Polimerização , Resinas Compostas/química , Lâmpadas de Polimerização Dentária , Polietilenoglicóis/química , Cura Luminosa de Adesivos Dentários , Ácidos Polimetacrílicos/química , Bis-Fenol A-Glicidil Metacrilato/química , Propriedades de Superfície , Poliuretanos/química , Compostos de Espiro/química , Metacrilatos/química , Módulo de Elasticidade
11.
Dent Mater J ; 43(4): 559-564, 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-38945865

RESUMO

This study investigated the usefulness of a dental laboratory polymerization unit with light-emitting diode (LED) as a light source. The depth of cure (n=15), water absorption and solubility (n=9) of two indirect composite materials (Cesead N and Solidex Hardura) were evaluated by five dental laboratory polymerization units (LED Cure Master, Twinkle LED, α-Light V, α-Light II, and Hyper LII). Statistical analysis was performed by one-way ANOVA and Tukey test or non-parametric tests. Comparison of light sources for curing depth showed that metal halide had the highest value, followed by the LED group with similar values, and halogen lamps with the lowest value. The water absorption and solubility of the composite specimens polymerized with the three LED laboratory polymerization units were within the ISO recommended limit.


Assuntos
Resinas Compostas , Lâmpadas de Polimerização Dentária , Teste de Materiais , Polimerização , Solubilidade , Água , Resinas Compostas/química , Resinas Compostas/efeitos da radiação , Água/química , Cura Luminosa de Adesivos Dentários
12.
Eur J Oral Sci ; 132(4): e12990, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38698528

RESUMO

This study examined the effect of high irradiance and short exposure times on the depth of cure of six resin-based composites (RBCs). Bluephase PowerCure and the Valo X light-curing units (LCUs) were used to photocure bulk-fill RBCs for their recommended exposure times: Admira Fusion x-tra (AFX/20s), Aura Bulk Fill (ABF/20s), Filtek One Bulk Fill (FOB/20s), Opus Bulk Fill APS (OBF/30s), Tetric EvoCeram Bulk Fill (TEC/10s) and Tetric PowerFill (TPF/10s). In addition, all bulk-fill RBCs were tested for depth of cure with one short 3 s exposure time from the Bluephase PowerCure or the Valo X in the Xtra Power mode. The RBCs (n = 10 per RBC) were inserted into a 4 mm diameter metal mold and covered by a polyester strip before being photocured. After 24 h of storage, uncured RBC was scraped away to determine the depth of cure of the RBCs. None of the RBCs achieved a 4 mm depth of cure. The depth of cure of TEC and TPF was unaffected by the exposure times (recommended or short) when using the Valo X. The depth of cure of AFX/20s, AFX/Xtra Power, ABF/Xtra Power, FOB/Xtra Power, and OBF/30s RBCs was greater when using Valo X compared to the Bluephase PowerCure. It was concluded that short exposure times can reduce depth of cure and should only be used for some RBCs.


Assuntos
Resinas Compostas , Lâmpadas de Polimerização Dentária , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Polimerização , Resinas Compostas/efeitos da radiação , Resinas Compostas/química , Fatores de Tempo , Humanos , Propriedades de Superfície
13.
Dent Mater ; 40(6): 951-957, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38734487

RESUMO

OBJECTIVE: This study examines the effect of two light-curing protocols from a LED polywave light curing unit (LCU) on water sorption, solubility, and hygroscopic expansion of fast and conventional bulk-fill resin-based composites (RBCs) aged in distilled water for 120 d. METHODS: Three bulk-fill RBCs materials were studied: Tetric PowerFill® (fast photo-polymerised composite) (TPF), Tetric EvoCeram bulk-fill (EVO), and GrandioSo x-tra bulk-fill (GSO) (conventional photo-polymerised composites). Specimens were prepared within a 3D-printed resin mold (8-mm diameter x 4-mm height) and light-cured from one side only with 2 modes of polywave LCU (Bluephase® PowerCure): 3 s mode and for 20 s in "Standard" mode. Water sorption and solubility were measured at fixed time intervals for 120 d of distilled water storage, then reconditioned to dry to measure desorption for 75 d, all at 37 ± 1 °C. Hygroscopic (volumetric) expansion was recorded at the same time intervals up to 120 d. Data were analysed through SPSS using Two-way ANOVA, One-way ANOVA, independent t-tests, and Tukey's post-hoc correction tests (p < 0.05). RESULTS: TPF, when irradiated for 3 s demonstrated minimal water sorption (0.83%), solubility (1.01 µg/mm3), and least volumetric expansion (1.64%) compared to EVO and GSO. While EVO showed the highest water sorption (1.03%) and solubility (1.95 µg/mm3) at 3 s. GSO had the lowest sorption (0.67%) and (0.56%) in 3 s and 20 s protocols, respectively. Nevertheless, all the sorption and solubility data were within the ISO 4049 limits. SIGNIFICANCE: For TPF, fast (3 s) polymerisation did not increase either water sorption or solubility, compared with 20 s irradiation. However, with the two comparative bulk-fill composites, fast cure increased water sorption by 15-25% and more than doubled solubility. These findings were consistent with the lesser volumetric expansions observed for Tetric PowerFill at both the fast and standard protocols, indicating its relative stability across polymerisation protocols.


Assuntos
Resinas Compostas , Teste de Materiais , Polimerização , Solubilidade , Água , Molhabilidade , Resinas Compostas/química , Água/química , Cura Luminosa de Adesivos Dentários , Lâmpadas de Polimerização Dentária , Impressão Tridimensional
14.
Oper Dent ; 49(3): 300-310, 2024 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-38632862

RESUMO

OBJECTIVES: The depth of cure using blue-light photocuring units (BL) is limited by tooth structure and qualities of the restorative material through which the activating wavelength must pass. Recent developments incorporate an infrared (IR) activated upconversion (UC) fluorescence of a lining agent filled with nanocrystals of NaYF4 and doped with YB+3 and Tm+3 that emit both blue and violet light locally at the interface of the liner and restorative resin. The purpose of this study was to evaluate the BL and 975 nm infrared (IR) light power transmission through dental tissues and restorative materials. METHODS AND MATERIALS: Power transmissions of the IR laser (975 nm) and a monowave blue-only light-curing unit (Bluephase 16i) through dental tissues (enamel, dentin, and enamel/dentin junction, or DEJ), eight (8) various dental resin composites, and eight (8) dental ceramics, each at four thicknesses (1, 2, 3 and 4 mm) were evaluated (n=5) using a thermopile sensor (PM10, Coherent Inc) connected to a laser power meter (Fieldmate, Coherent Inc). Power transmission values of each light source and restorative material were subjected to analysis of variance and Tukey test at a pre-set alpha of 0.05. RESULTS: A linear correlation (r=0.9884) between the supplied current and emitted IR power of the laser diode was found, showing no statistical power reduction with increased distances (collimated beam). For tooth tissues, the highest power transmissions for both light sources were observed using 1.0 mm enamel while the lowest values were found for 2.0 mm dentin and an association of 2.0 mm DEJ and 1.0 mm dentin. The only group where IR demonstrated significantly higher transmission when compared to BL was 1.0 mm enamel. For all resin composites and dental ceramics, increased thickness resulted in a reduction of IR power transmission (except for EverX Posterior fiber-reinforced composite and e.max HT ceramic). IR resulted in higher transmission through all resin composites, except for Tetric EvoCeram White. The highest BL transmission was observed for SDR Flow, at all thicknesses. Higher IR/BL ratios were observed for EverX Posterior, Herculite Ultra, and Lava Ultimate, while the lowest ratio was observed for Tetric EvoCeram White. Reduced translucency shades within the same material resulted in lower power ratio values, especially for BL transmission. Higher IR/BL ratios were observed for e.Max LT, VitaVM7 Base Dentin, and e.max CAD HT, while the lowest values were found for VitaVM7 Enamel and Paradigm C. CONCLUSION: IR power transmission through enamel was higher when compared to blue light, while no difference was observed for dentin. The power transmission of IR was higher than BL for resin composites, except for a high value and low chroma shade. Fiber-reinforced resin composite demonstrated the highest IR/BL power transmission ratio. A greater IR/BL ratio was observed for lower translucency ceramics when compared to high translucency.


Assuntos
Resinas Compostas , Lâmpadas de Polimerização Dentária , Materiais Dentários , Raios Infravermelhos , Resinas Compostas/química , Humanos , Materiais Dentários/química , Restauração Dentária Permanente/métodos , Cerâmica , Teste de Materiais , Dentina/efeitos da radiação , Esmalte Dentário/efeitos da radiação
15.
J Dent ; 145: 104998, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38636650

RESUMO

OBJECTIVES: The study aimed to introduce a novel two-step optical fiber-based photo-activation of dental resin-based composites (RBCs) for reducing polymerization shrinkage stress (PSS). METHODS: Proposed protocol design - in the first step, two flexible plastic optical fibers connected to a dental light curing unit (LCU), were used as light guides inserted into the filling to initiate low-irradiance polymerization from within; in the second step, fibers were extracted and remaining voids were filled with RBC, followed by conventional high-irradiance curing to finalize polymerization. Three bulk-fill RBCs were tested (Beautifil-Bulk Restorative, Filtek Bulk-fill Posterior, Tetric PowerFill) using tooth cavity models. Three non-invasive examination techniques were employed: Digital Holographic Interferometry, Infrared Thermography, and Raman spectroscopy for monitoring model deformation, RBC temperature change, and degree of conversion (DC), respectively. A control group (for each examined RBC) underwent conventional photo-activation. RESULTS: The experimental protocol significantly reduced model deformation by 15 - 35 %, accompanied by an 18 - 54 % reduction in RBC temperature change, emphasizing the impact of thermal shrinkage on PSS. Real-time measurements of deformation and temperature provided indirect insights into reaction dynamics and illuminated potential mechanisms underlying PSS reduction. After a 24-hour dark-storage period, DC outcomes comparable to conventional curing were observed, affirming the clinical applicability of the method. CONCLUSIONS: Protocol involving the use of two 1.5 mm fibers in the first step (300 mW/cm2 x 10 s), followed by a second conventional curing step (1000 mW/cm2 x 10 s), is recommended to achieve the desired PSS reduction, while maintaining adequate DC and ensuring efficient clinical application. CLINICAL SIGNIFICANCE: Obtained PSS reduction offers promise in potentially improving the performance of composite restorations. Additionally, leveraging the flexibility of optical fibers improves light guide approach for restorations on posterior teeth. Meanwhile, implementation in clinical practice is easily achievable by coupling the fibers with commercial dental LCUs using the provided plastic adapter.


Assuntos
Resinas Compostas , Teste de Materiais , Fibras Ópticas , Polimerização , Resinas Compostas/química , Resinas Compostas/efeitos da radiação , Humanos , Lâmpadas de Polimerização Dentária , Materiais Dentários/química , Materiais Dentários/efeitos da radiação , Temperatura , Análise Espectral Raman , Cura Luminosa de Adesivos Dentários/métodos , Estresse Mecânico , Propriedades de Superfície
16.
Dent Mater ; 40(5): 837-841, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38570242

RESUMO

OBJECTIVES: to assess the impact of universal adhesives, cured with single-peak and polywave LEDs, on the metabolic activity and cytokine release of human dental pulp stem cells (hDPSCs). In addition, analyze the degree of conversion (DC) of the adhesives cured with the different LEDs. METHODS: Discs (5 mm diameter, 1 mm thick) were prepared using three universal adhesives: Single Bond Universal (SBU, 3 M ESPE), Optibond Universal (OBU, Kerr), and Zipbond Universal (ZBU, SDI). These discs were cured for 40 s using a single-peak (DeepCure, 3 M ESPE) or a polywave light-emmiting diode (LED) curing unit (Valo Grand, Ultradent). After 24 h, the specimens were placed in 24-well culture plates, each containing 1 mL of culture medium for 24 h. hDPSCs (1.8 ×104) were seeded in 96-well plates and allowed to grow for 24 h. Subsequently, the cells were exposed to the extracts (culture medium containing eluates from the adhesive discs) for an additional 24 h. Cells not exposed to the extracts were used as a control group. The mitochondrial metabolism was assessed using the MTT assay and the cytokine release evaluated through MAGPIX. The degree of conversion of the adhesives was analyzed using FTIR (n = 5). The results were analyzed by ANOVA two-way and Tukey's test. RESULTS: OBU and ZBU eluates caused a statistically significant reduction in mitochondrial metabolism, regardless of the LED used, indicating their cytotoxicity. In contrast, SBU did not significantly affect the MTT results, resembling the control group. A higher release of cytokines IL-1, IL-6, IL-10, and TNF-α were found in association to ZBU. SBU, on the other hand, increased the release of IL-8. OBU did not influenced the cytokine release. SBU presented the higher DC, while OBU and ZBU had similar DC, lower than SBU. SIGNIFICANCE: In conclusion, universal adhesives exhibit toxicity towards hDPSCs, but the extent of toxicity varies depending on the adhesive material. ZBU was associated with increased cytokine release, particularly pro-inflammatory mediators, from hDPSCs. The different LEDs did not influenced the cytotoxicity of the evaluated adhesives.


Assuntos
Lâmpadas de Polimerização Dentária , Citocinas , Cimentos Dentários , Polpa Dentária , Teste de Materiais , Células-Tronco , Humanos , Polpa Dentária/citologia , Citocinas/metabolismo , Cimentos Dentários/química , Cimentos Dentários/farmacologia , Cura Luminosa de Adesivos Dentários , Cimentos de Resina/química , Cimentos de Resina/toxicidade , Células Cultivadas , Bis-Fenol A-Glicidil Metacrilato/toxicidade , Bis-Fenol A-Glicidil Metacrilato/química
17.
Quintessence Int ; 55(4): 264-272, 2024 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-38362702

RESUMO

OBJECTIVES: The objective was to evaluate the polymerization efficiency of different bulk-fill resin-based composites cured by monowave and polywave light-curing units, by assessment of the degree of conversion and Vickers microhardness at different depths. METHOD AND MATERIALS: Two commercially available bulk-fill resin-based composites were used: Filtek One Bulk Fill Restorative (3M ESPE) and Tetric N-Ceram Bulk Fill (Ivoclar Vivadent). The light-curing units utilized were two LED light-curing units: a monowave LED light-curing unit (BlueLEX LD-105, Monitex) and a polywave LED light-curing unit (Twin Wave GT-2000, Monitex). For each test, 20 cylindrical specimens (4 mm diameter, 4 mm thickness) were prepared from each bulk-fill resin-based composite using a split Teflon mold. Ten specimens were light-cured by the monowave light-curing unit and the other ten were light-cured by the polywave light-curing unit according to the manufacturer's recommendations. Attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) was used to assess the degree of conversion, and a Vickers microhardness tester was used to assess Vickers microhardness. Statistical analysis was performed using three-way ANOVA and Tukey post-hoc tests (P < .05). RESULTS: The degree of conversion and Vickers microhardness in bulk-fill resin-based composites containing only camphorquinone as photoinitiator were similar when cured with either monowave or polywave light-curing units. However, bulk-fill resin-based composites containing a combination of photoinitiators exhibited significantly higher degree of conversion and Vickers microhardness when cured with a polywave light-curing unit. Although all groups showed statistically significant differences between the top and bottom surfaces regarding degree of conversion and Vickers microhardness, all of them showed bottom/top ratios > 80% regarding degree of conversion and Vickers microhardness. CONCLUSION: The polywave light-curing unit enhanced the polymerization efficiency of bulk-fill resin-based composites especially when the latter contained a combination of photoinitiators, but does not prevent the use of a monowave light-curing unit.


Assuntos
Resinas Compostas , Lâmpadas de Polimerização Dentária , Dureza , Teste de Materiais , Polimerização , Resinas Compostas/química , Resinas Compostas/efeitos da radiação , Propriedades de Superfície , Cura Luminosa de Adesivos Dentários/métodos , Espectroscopia de Infravermelho com Transformada de Fourier
18.
Dent Mater ; 40(3): 546-556, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38326211

RESUMO

OBJECTIVES: This study investigated effects of the different emittance-mode protocols from three light curing units (LCUs): (i) a Laser (Monet); (ii) a quad-wave (PinkWave); (iii) a conventional LED (Elipar S10) on the temperature rise (ΔT) and degree of conversion (DC) when photo-curing fast or conventional bulk-fill resin-based composites (RBC). The aim was to correlate ΔT and DC, and the radiant exposure delivered to RBC specimens. METHODS: A 3D-printed resin mold of 4 mm depth was filled with two bulk-fill RBCs: Tetric PowerFill® (fast photo-polymerised composite) (TPF) or Tetric EvoCeram® Bulk-Fill (EVO). Three LCUs were used: (i) Monet laser for 1 s and 3 s (MONET-1 s, MONET-3 s); (ii) PinkWave quad-wave used for 3 s in Boost mode (PW-3 s) and for 20 s in standard mode (PW-20 s); (iii) Elipar S10 for 5 s (S10-5 s) and for 20 s in standard mode (S10-20 s). 2-dimensional temperature maps were obtained before, during and for 60 s after the LCU had turned off using a thermal imaging camera. Thermal changes were analysed at five depths: (0, 1, 2, 3, and 4 mm from the top surface of the RBC). The maximum temperature rise (Tmax) and the mean temperature rise (ΔT) were determined. Cylindrical-shaped specimens were prepared from each material using a stainless-steel split mold (4 × 4 mm) and light-cured with the same protocols. The DC was measured for 120 s and at 1 h after LCU had turned off using Fourier Transform Infrared Spectroscopy (FTIR). Data were analysed using Three-way ANOVA, One-way ANOVA, independent t-tests, and Tukey post-hoc tests (p < 0.05). RESULTS: Radiant exposures delivered by the various irradiation protocols were between 4.5-30.3 J/cm2. Short exposure times from MONET-1 s and PW-3 s delivered the lowest radiant exposures (4.5 and 5.2 J/cm2, respectively) and produced the lowest ΔT and DC. The longer exposure times in the standard modes of PW-20 s, S10-20 s, and MONET-3 s produced the highest Tmax, ΔT, and DC for both composites. The ΔT range among composites at different depths varied significantly (31.7-49.9 °C). DC of TPF ranged between 30-65% and in EVO between 15.3-56%. TPF had higher Tmax, ΔT for all depths and DC compared to EVO, across the LCU protocols (p < 0.05), except for PW-20 s and MONET-3 s. The coronal part of the restorations (1-2 mm) had the highest ΔT. There was a positive correlation between ΔT and DC at 4-mm depth after 120 s SIGNIFICANCE: Longer, or standard, exposure times of the LCUs delivered greater radiant exposures and had higher DC and ΔT compared to shorter or high-irradiance protocols. The fast photo-polymerised RBC had comparatively superior thermal and conversion outcomes when it received a high irradiance for a short time (1-5 s) compared to the conventional Bulk-Fill RBC.


Assuntos
Lâmpadas de Polimerização Dentária , Termografia , Teste de Materiais , Resinas Compostas/química , Materiais Dentários , Cura Luminosa de Adesivos Dentários/métodos , Polimerização
19.
J Adhes Dent ; 26(1): 31-40, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38276890

RESUMO

PURPOSE: To compare the adhesion of a self-curing (Tokuyama Universal Bond, TUB) and a light-curing (Scotchbond Universal, SBU) universal adhesive to CAD/CAM materials, enamel, and dentin. This study also assessed differences in enamel adhesion between self-etch vs selective etching modes, as well as immediate and long-term adhesion to dentin for both adhesives. MATERIALS AND METHODS: Shear bond strength (SBS) testing was used to assess adhesion to enamel, dentin, Lava Ultimate (LU), Vita Enamic (VE), IPS e.max CAD (LD), IPS e.max ZirCAD (3Y-Zir), and Lava Esthetic (5Y-Zir) (n = 10). Moreover, bonding to enamel in self-etch and selective etching modes (n = 10) as well as immediate and aged resin-dentin bond strength (24 h after bonding, after 100,000 thermal cycles [TC] and long-term storage) was evaluated using the microtensile bond-strength test (n = 30). Failure mode was also determined for the bonding to dentin. Statistical analyses consisted of one-way and two-way ANOVA with appropriate post-hoc Tukey-Kramer or two-sample t-tests, as well as the chi-squared or Fisher's exact test (α = 0.05). RESULTS: TUB and SBU universal adhesives presented similar bonding to LU, VE, 3Y-Zir, and 5Y-Zir. However, SBS for TUB was superior to SBU when bonding to lithium-disilicate glass-ceramic (IPS e.max CAD). SBU showed better adhesion to dentin and enamel when used in the self-etch mode, while TUB promoted strong bond strength to enamel in the selective etching mode. TUB after TC was the only aging condition that yielded a significant reduction in resin-dentin bond strength. CONCLUSION: In-vitro adhesion performance of the self-curing and light-curing universal adhesives varies depending on the dental substrate or CAD/CAM restorative material used for bonding.


Assuntos
Colagem Dentária , Cimentos Dentários , Adesivos Dentinários/química , Cura Luminosa de Adesivos Dentários , Lâmpadas de Polimerização Dentária , Cimentos de Resina/química , Teste de Materiais , Resistência ao Cisalhamento , Dentina
20.
Oper Dent ; 49(1): 43-51, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38180469

RESUMO

The rise in temperature in pulp tissues is related not only to heat transfer by high-irradiance light-curing units (LCUs), but also to restorative procedures. This research aimed to compare the rise in pulp temperature (PT) induced by three LCUs at each restorative step while considering the influence of resin composite shade and thickness. To accomplish this, the investigators used a proposed experimental model replicating pulp fluid circulation with a controlled, simulated intraoral temperature in bovine incisors. The recorded external and internal PT ranged from 36.7°C to 37.1°C and 32.7°C to 33.0°C, respectively. A significant decrease of internal temperature was recorded during class V preparation, followed by a progressive and representative rise of temperature in the subsequent restorative steps. The temperature was significantly higher during light curing of the adhesive system using Valo compared to light curing using Elipar and Radii Cal. However, none of the analyzed devices produced a temperature that exceeded the pulp tolerance limit (a temperature increase over 5.5°C). The paired test showed no significant difference in pulp temperature associated with the thickness of the increment of resin composite. However, shade was found to have more influence on the amount of energy absorbed by pulp tissue-A1 samples showed significantly higher temperature variation compared to samples using the A4 shade of resin composite. To conclude, the microcirculation and the performance of procedures under constant air-water flux dissipate the heat absorbed by the pulp. Additionally, the data suggest that all three LCUs analyzed can be safely used in clinical procedures, and that the resin composite shade may influence the amount of irradiance delivered to the tooth surface and represents a significant factor in pulp temperature variance.


Assuntos
Lâmpadas de Polimerização Dentária , Cura Luminosa de Adesivos Dentários , Animais , Bovinos , Temperatura , Temperatura Alta , Resinas Compostas/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA