Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 11.505
Filtrar
1.
BMC Ophthalmol ; 24(1): 233, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38831268

RESUMO

BACKGROUND: The long-term safety and efficacy of repeated applications of subliminal transscleral cyclophotocoagulation (SL-TSCPC) with a focus on cumulative energy was evaluated in glaucoma patients. METHODS: In this retrospective, multicentric study the data of a total of 82 eyes with various causes of glaucoma that were treated with a single or multiple applications of SL-TSCPC were collected. Treatments were performed under general or local anesthesia with an 810 nm diode laser. Power was 2000 mW; duty cycle, 31.3%; total treatment duration, 80-320 s; equaling a total energy of 50-200 J per treatment session. Fifty-five eyes (55 patients) presented for all follow-ups, and these eyes were selected for further statistical analysis. The mean age was 60.0 ± 17.1 years, and 22 (40%) of the patients were female. Intraocular pressure (IOP) and dependence on further glaucoma medication were evaluated at 12 months following the initial treatment. RESULTS: Eyes underwent 1 or 2 consecutive SL-TSCPC treatments. Median (min-max) baseline IOP of 34 (13-69) decreased to 21.5 (7-61), 22 (8-68), 20 (9-68), and 19.5 (3-60) mmHg at the 1, 3, 6, and 12-month postoperative timepoints respectively. The mean (± SD) IOP decrease at 12 months was 26 ± 27%, 39 ± 32%, and 49 ± 33% in the low (below 120 J, n = 18), medium (120-200 J, n = 24), and high (above 200 J, n = 13) cumulative energy groups respectively. At the 12-month timepoint, oral carbonic anhydrase use was discontinued in ¾ of the cases. CONCLUSIONS: It was found that the repeated application of SL-TSCPC safely and efficiently decreases IOP in a Caucasian population with heterogenous causes of glaucoma, eyes with silicone oil responded to a greater extent. Inclusion of cumulative energy scales may contribute to better addressing repeated procedures in a standardized fashion.


Assuntos
Corpo Ciliar , Glaucoma , Pressão Intraocular , Fotocoagulação a Laser , Lasers Semicondutores , Esclera , Humanos , Estudos Retrospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Pressão Intraocular/fisiologia , Fotocoagulação a Laser/métodos , Corpo Ciliar/cirurgia , Idoso , Esclera/cirurgia , Glaucoma/cirurgia , Glaucoma/fisiopatologia , Adulto , Lasers Semicondutores/uso terapêutico , Acuidade Visual/fisiologia , Idoso de 80 Anos ou mais , Seguimentos , Resultado do Tratamento
2.
BMC Ophthalmol ; 24(1): 235, 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38840075

RESUMO

AIMS: To explore the application and long-term clinical effects of modified Yamane technique in intrascleral intraocular lens (IOL) fixation combined with or without iris reconstruction. SETTINGS AND DESIGN: The data of patients receiving IOL fixation with modified Yamane technique in an ophthalmology department between December 2021 and August 2023 were analyzed retrospectively. The longest follow-up duration was > 12 months. METHODS AND MATERIAL: The trailing haptic was fixed with the needle before the leading haptic. The silicone haptic stoppers were used to stabilize the IOL when iris reconstruction was combined. Preoperative and postoperative best-corrected visual acuity (BCVA), corneal endothelial cells (CECs), postoperative intraocular pressure (IOP), surgical indications and methods, and postoperative complications were recorded. Anterior segment optical coherence tomography (OCT) was used to evaluate IOL decentration and tilt. The paired sample t-test or Wilcoxon rank sum test were used to compare the results of the same index before and after the operation. RESULTS: Twelve patients (12 eyes) were included in this cohort. There were 1 case of IOL dislocation, eight cases of lens dislocation or subluxation, and three cases of aphakia. Traumatic lens dislocation was the main cause of aphakia. Primary lens extraction was performed in previous surgeries, and all three were combined with pars plana vitrectomy (PPV). Four of 12 patients underwent IOL fixation and iris reconstruction. The mean age of participants was 63 ± 10.61 years. The mean BCVA increased from 0.89 ± 0.72 logMAR to 0.39 ± 0.56 logMAR at the last visit (p < 0.05). The postoperative relative refractive error was - 0.13 ± 0.42 D (-0.60 D to + 0.57 D). The OCT showed that the IOLs were well centered, with a mean decentration of 0.20 ± 0.13 mm and a mean tilt of 2.31°±0.93°. Ten patients did not experience any complications. CONCLUSIONS: The modified Yamane technique in IOL fixation surgery, especially combined with iris reconstruction, reduces operation difficulty, increases operational stability and safety, and improves postoperative visual acuity without serious intra- or postoperative complications. The long-term improvement effect was remarkable.


Assuntos
Iris , Implante de Lente Intraocular , Lentes Intraoculares , Esclera , Acuidade Visual , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Implante de Lente Intraocular/métodos , Iris/cirurgia , Idoso , Acuidade Visual/fisiologia , Esclera/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Tomografia de Coerência Óptica/métodos , Seguimentos
3.
Zhonghua Yan Ke Za Zhi ; 60(6): 503-510, 2024 Jun 11.
Artigo em Chinês | MEDLINE | ID: mdl-38825949

RESUMO

Objective: To evaluate the efficacy of sutureless intrascleral intraocular lens (IOL) fixation with the modified Yamane technique. Methods: It was a retrospective case series study. Patients undergoing sutureless intrascleral IOL fixation with the modified Yamane technique were included at Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University from January 2022 to September 2023. Uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA), recorded as the logarithm of the minimum angle of resolution (logMAR), were measured before surgery and at 1 day, 3 days, 1 week, 1 month, and 3 months postoperatively. Refractive error and intraocular pressure were also checked. Anterior segment examination with a slit lamp microscope, fundus examination, anterior segment and posterior segment optical coherence tomography were performed. Intraoperative and postoperative ocular complications were documented. Results: A total of 53 patients (53 eyes) were included in this study, comprising 40 males and 13 females, with a median age of 60 (49, 68) years. Among them, the proportion of a history of trauma was 22.6% (12/53). There was 1 eye with intraoperative vitreous hemorrhage (1.9%). All eyes had no obvious hypotony, no obvious inflammation in the anterior chamber, and no pupillary abnormalities at 1 week after surgery. The mean follow-up time was (8.0±3.3) months (range, 3 to 16 months). There was no iris capture, re-dislocation, or haptic exposure of the IOL during the follow-up. The corneal endothelial cell density was (2 236±704) cells/mm2 preoperatively and (1 964±628) cells/mm2 at 1 month, with significant difference (P<0.001). The UCVA (logMAR) was 1.53±0.75 preoperatively, 0.18±0.17 at 1 month, 0.15±0.14 at 3 months, and 0.14±0.13 at the final visit (P<0.001). The UCVA (logMAR) at 1 month was significantly different from that at 3 months and the final visit (both P<0.05). At 1 month, 50.9% (27/53) of the eyes had an UCVA (logMAR)≤0.1, and the rate was 56.6% (30/53) at 3 months. The BCVA (logMAR) was 0.25±0.21, 0.03±0.06, 0.02±0.06, and 0.02±0.06 before surgery, at postoperative1 month, 3 months, and the final visit, respectively (P<0.001). The BCVA (logMAR) at 1 month was not significantly different from that at 3 months and the final visit (both P>0.05). The rate of the eyes with a BCVA (logMAR)≤0 was 81.1% (43/53) at 1 month and 83.0% (44/53) at 3 months. The IOL tilt was (5.18±2.60)° at postoperative 1 month and (5.08±2.48)° at postoperative 3 months, without statistically significant difference (P>0.05). The IOL decentration was (0.35±0.24) mm at postoperative 1 month and (0.32±0.24) mm at postoperative 3 months, without statistically significant difference (P>0.05). Conclusion: Sutureless intrascleral IOL fixation with the modified Yamane technique is simpler and more minimally invasive to achieve a stable and centered IOL implantation with fewer complications and good visual prognosis.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Humanos , Pessoa de Meia-Idade , Masculino , Feminino , Estudos Retrospectivos , Idoso , Implante de Lente Intraocular/métodos , Esclera/cirurgia , Acuidade Visual , Procedimentos Cirúrgicos sem Sutura/métodos
4.
BMC Ophthalmol ; 24(1): 246, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38862935

RESUMO

BACKGROUND: To compare the ocular features of highly myopic eyes with posterior staphyloma of wide macular type according to its morphological complexity. METHODS: In this cross-sectional study, wide macular posterior staphyloma (WMPS) was classified into the primary (Curtin type I) and the compound (Curtin types VI to X) forms based on the configuration within the staphyloma. The grades of myopic maculopathy and the thicknesses of choroid and sclera were compared between the primary and compound forms of WMPS. RESULTS: A total of 154 eyes (103 patients) with primary WMPS and 65 eyes (49 patients) with compound WMPS were included. Eyes with compound WMPS had worse visual acuity (P = 0.001) and greater axial length (P < 0.001) than those with primary WMPS. Compared to primary WMPS, compound WMPS had a higher grade of myopic macular degeneration (P < 0.001) and a higher frequency of lamellar or full-thickness macular hole associated with myopic traction (21.5% vs. 10.4%; P = 0.028) and active or scarred myopic choroidal neovascularization (33.8% vs. 20.1%; P = 0.030). On swept-source optical coherence tomography, eyes with compound WMPS had significantly thinner choroid and sclera. CONCLUSIONS: The compound form of WMPS had more severe myopic macular changes and worse visual prognosis compared to the primary form of WMPS, and these were associated with more structural deformation in the posterior eyeball. Compound WMPS should be considered as an advanced form of staphyloma.


Assuntos
Miopia Degenerativa , Esclera , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Feminino , Masculino , Estudos Transversais , Miopia Degenerativa/complicações , Miopia Degenerativa/diagnóstico , Pessoa de Meia-Idade , Acuidade Visual/fisiologia , Tomografia de Coerência Óptica/métodos , Idoso , Esclera/patologia , Estudos Retrospectivos , Adulto , Corioide/patologia , Corioide/diagnóstico por imagem , Doenças da Esclera/diagnóstico , Macula Lutea/patologia , Macula Lutea/diagnóstico por imagem , Dilatação Patológica
5.
Sci Rep ; 14(1): 13689, 2024 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-38871803

RESUMO

This study aims to correlate adaptive optics-transscleral flood illumination (AO-TFI) images of the retinal pigment epithelium (RPE) in central serous chorioretinopathy (CSCR) with standard clinical images and compare cell morphological features with those of healthy eyes. After stitching 125 AO-TFI images acquired in CSCR eyes (including 6 active CSCR, 15 resolved CSCR, and 3 from healthy contralateral), 24 montages were correlated with blue-autofluorescence, infrared and optical coherence tomography images. All 68 AO-TFI images acquired in pathological areas exhibited significant RPE contrast changes. Among the 52 healthy areas in clinical images, AO-TFI revealed a normal RPE mosaic in 62% of the images and an altered RPE pattern in 38% of the images. Morphological features of the RPE cells were quantified in 54 AO-TFI images depicting clinically normal areas (from 12 CSCR eyes). Comparison with data from 149 AO-TFI images acquired in 33 healthy eyes revealed significantly increased morphological heterogeneity. In CSCR, AO-TFI not only enabled high-resolution imaging of outer retinal alterations, but also revealed RPE abnormalities undetectable by all other imaging modalities. Further studies are required to estimate the prognosis value of these abnormalities. Imaging of the RPE using AO-TFI holds great promise for improving our understanding of the CSCR pathogenesis.


Assuntos
Coriorretinopatia Serosa Central , Epitélio Pigmentado da Retina , Tomografia de Coerência Óptica , Humanos , Epitélio Pigmentado da Retina/diagnóstico por imagem , Epitélio Pigmentado da Retina/patologia , Coriorretinopatia Serosa Central/diagnóstico por imagem , Coriorretinopatia Serosa Central/patologia , Masculino , Feminino , Pessoa de Meia-Idade , Tomografia de Coerência Óptica/métodos , Adulto , Angiofluoresceinografia/métodos , Imagem Óptica/métodos , Esclera/diagnóstico por imagem , Esclera/patologia
6.
Zhonghua Yan Ke Za Zhi ; 60(5): 403-407, 2024 May 11.
Artigo em Chinês | MEDLINE | ID: mdl-38706077

RESUMO

Over the years, there has been significant advancement in the safety and effectiveness of external cyclosurgery for glaucoma. This progress ranges from the initial "cyclodestructive surgery" to modern cycloplasty techniques, expanding beyond end-stage glaucoma treatment. Notably, innovative approaches like micropulse transscleral cycloplasty and ultrasonic cycloplasty are now being employed in earlier stages of glaucoma with better visual acuity, qualifying as minimally invasive procedures. Through a comprehensive review of the historical evolution of external cyclosurgery, elucidation of the mechanisms, clinical outcomes, and potential complications associated with novel cycloplasty techniques, and integration of practical clinical insights, this article aims to furnish clinicians with a profound comprehension of external cyclosurgery for glaucoma.


Assuntos
Corpo Ciliar , Glaucoma , Procedimentos Cirúrgicos Minimamente Invasivos , Esclera , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Glaucoma/cirurgia , Esclera/cirurgia , Corpo Ciliar/cirurgia
7.
Sci Rep ; 14(1): 11382, 2024 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-38762668

RESUMO

The annual increase in myopia prevalence poses a significant economic and health challenge. Our study investigated the effect of calcitriol role in myopia by inducing the condition in guinea pigs through form deprivation for four weeks. Untargeted metabolomics methods were used to analyze the differences in metabolites in the vitreous body, and the expression of vitamin D receptor (VDR) in the retina was detected. Following form deprivation, the guinea pigs received intraperitoneal injections of calcitriol at different concentrations. We assessed myopia progression using diopter measurements and biometric analysis after four weeks. Results indicated that form deprivation led to a pronounced shift towards myopia, characterized by reduced choroidal and scleral thickness, disorganized collagen fibers, and decreased scleral collagen fiber diameter. Notably, a reduction in calcitriol expression in vitreous body, diminished vitamin D and calcitriol levels in the blood, and decreased VDR protein expression in retinal tissues were observed in myopic guinea pigs. Calcitriol administration effectively slowed myopia progression, preserved choroidal and scleral thickness, and prevented the reduction of scleral collagen fiber diameter. Our findings highlight a significant decrease in calcitriol and VDR expressions in myopic guinea pigs and demonstrate that exogenous calcitriol supplementation can halt myopia development, enhancing choroidal and scleral thickness and scleral collagen fiber diameter.


Assuntos
Calcitriol , Miopia , Retina , Animais , Cobaias , Miopia/metabolismo , Miopia/tratamento farmacológico , Miopia/patologia , Calcitriol/farmacologia , Retina/metabolismo , Retina/efeitos dos fármacos , Retina/patologia , Receptores de Calcitriol/metabolismo , Receptores de Calcitriol/genética , Masculino , Modelos Animais de Doenças , Esclera/metabolismo , Esclera/efeitos dos fármacos , Esclera/patologia , Corioide/metabolismo , Corioide/efeitos dos fármacos , Corioide/patologia , Vitamina D/farmacologia , Vitamina D/administração & dosagem , Comprimento Axial do Olho , Corpo Vítreo/metabolismo , Corpo Vítreo/efeitos dos fármacos , Progressão da Doença , Colágeno/metabolismo
8.
Vestn Oftalmol ; 140(2): 72-77, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38742501

RESUMO

The modern treatment strategy for keratoconus (KC) involves sequential application of medical technologies aimed at stabilizing pathological changes in the cornea and restoring visual acuity. PURPOSE: This study compares the effect of implantation of intrastromal corneal ring segment (ICRS) and fitting of individual scleral rigid contact lenses (RCLs) on visual functions in patients with stage II-III KC after previously performed corneal collagen cross-linking. MATERIAL AND METHODS: The Helmholtz National Medical Research Center of Eye Diseases examined and treated 34 patients (69 eyes) aged 18 to 33 years with stage II-III KC. The study included patients who had previously undergone standard corneal collagen cross-linking. Depending on the type of optical correction, the patients were divided into two groups: patients in group 1 underwent ICRS implantation using a femtosecond laser; patients in group 2 were fitted with individual scleral RCLs. RESULTS: Improvement in clinical and functional parameters was observed in both groups. A higher clinical and functional result was achieved in group 2. CONCLUSION: For patients with stable stage II-III KC, it is advisable to recommend fitting of individual scleral RCLs for visual rehabilitation.


Assuntos
Lentes de Contato , Ceratocone , Esclera , Acuidade Visual , Humanos , Ceratocone/cirurgia , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Ceratocone/terapia , Feminino , Masculino , Adulto , Esclera/cirurgia , Implantação de Prótese/métodos , Implantação de Prótese/instrumentação , Resultado do Tratamento , Topografia da Córnea , Próteses e Implantes , Adulto Jovem , Ajuste de Prótese/métodos , Adolescente , Substância Própria/cirurgia
9.
Arch. Soc. Esp. Oftalmol ; 99(5): 213-217, May. 2024. mapas
Artigo em Espanhol | IBECS | ID: ibc-VR-73

RESUMO

Presentamos un reporte de caso en una paciente de 70años sobre las calcificaciones esclerocoroideas, una rara condición que involucra depósitos de pirofosfato de calcio en el polo posterior del ojo. Proporcionamos un relato sobre la presentación clínica y su apariencia en imágenes multimodales, utilizando fotografías de color del fondo de ojo, tomografía de coherencia óptica de fuente de barrido (SS-OCT), ecografía ocular y la novedosa técnica de retromodo (RMI). Al examen la agudeza visual fue de 20/25 en el ojo derecho y de 20/20 en el ojo izquierdo. La fotografía de color del fondo de ojo reveló depósitos amarillentos localizados en la arcada temporal-superior de ambos ojos. SS-OCT demostró masas de origen escleral. Las ecografías oculares confirmaron la calcificación de estas masas. El RMI detectó imágenes hiperreflectivas con una marcada elevación superficial de las lesiones. El laboratorio sistémico no presentó alteraciones, lo que llevó al diagnóstico de calcificaciones esclerocoroideas bilaterales de origen idiopático.(AU)


We present a case report on sclerochoroidal calcification (SCC), a rare condition involving calcium pyrophosphate deposits in the posterior pole of the eye in a 70-year-old patient. We provide an account of the clinical presentation and its appearance in multimodal images, using color fundus photography, swept-source optical coherence tomography (SS-OCT), ocular ultrasound, and the novel retro-mode imaging (RMI) technique. Visual acuity was 20/25 in the right eye (OD) and 20/20 in the left eye (OS). Color fundus photography revealed yellowish deposits located in the upper temporal arcade of both eyes. SS-OCT demonstrated masses of scleral origin. Ocular ultrasounds confirmed the calcification of these masses. RMI detected hyper-reflective images with marked superficial elevation. Systemic laboratory results did not detect any abnormalities, leading to the diagnosis of bilateral idiopathic SCC.(AU)


Assuntos
Humanos , Feminino , Idoso , Imagem Multimodal , Fundo de Olho , Tomografia de Coerência Óptica , Visão Ocular , Esclera/lesões , Doenças da Esclera , Pacientes Internados , Exame Físico , Oftalmologia , Oftalmopatias
10.
BMJ Case Rep ; 17(5)2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38802253

RESUMO

A female in her 20s presented with a diminution of vision in the right eye (RE) following an open globe injury (scleral penetration) and repair a year back. At the presentation, she had low intraocular pressure (IOP) of 7 mm Hg, posterior subcapsular cataract (PSC), retrolental vitreous bands incarcerated at the penetration site, disc oedema, tortuous vessels and choroidal folds. Inferotemporal and superonasal cyclodialysis clefts were detected on CASIA 2 optical coherence tomography (OCT). The diagnosis of RE repaired scleral penetration, PSC and cyclodialysis cleft with hypotony maculopathy was made. The case was managed by phacoemulsification with an intraocular lens in the bag and a capsular tension ring in the sulcus, as a tamponading agent to close the cleft. Intraoperatively on endoscopic visualisation, vitreous membrane was noticed encasing the ciliary processes causing a tractional cyclodialysis and hence single port 23G pars plana vitrectomy was performed to relieve the traction. Postsurgery, IOP was 14 mm Hg, and the repaired cleft was visualised on anterior segment OCT.


Assuntos
Fendas de Ciclodiálise , Tomografia de Coerência Óptica , Vitrectomia , Adulto , Feminino , Humanos , Fendas de Ciclodiálise/cirurgia , Fendas de Ciclodiálise/etiologia , Tamponamento Interno/métodos , Ferimentos Oculares Penetrantes/cirurgia , Ferimentos Oculares Penetrantes/complicações , Pressão Intraocular/fisiologia , Facoemulsificação , Esclera/cirurgia , Vitrectomia/métodos
11.
Invest Ophthalmol Vis Sci ; 65(5): 34, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38776117

RESUMO

Purpose: A thin cornea is a potent risk factor for glaucoma. The underlying mechanisms remain unexplained. It has been postulated that central corneal thickness (CCT) may be a surrogate for biomechanical parameters of the posterior eye. In this study, we aimed to explore correlations of biomechanical responses between the cornea and the optic nerve head (ONH) and the peripapillary sclera (PPS) to elevated intraocular pressure (IOP), the primary risk factor of glaucoma. Methods: Inflation tests were performed in nine pairs of human donor globes. One eye of each pair was randomly assigned for cornea or posterior eye inflation. IOP was raised from 5 to 30 millimeters of mercury (mmHg) at 0.5 mmHg steps in the whole globe and the cornea or the ONH/PPS was imaged using a 50 MHz ultrasound probe. Correlation-based ultrasound speckle tracking was used to calculate tissue displacements and strains. Associations of radial, tangential, and shear strains at 30 mmHg between the cornea and the ONH or PPS were evaluated. Results: Corneal shear strain was significantly correlated with ONH shear strain (R = 0.857, P = 0.003) and PPS shear strain (R = 0.724, P = 0.028). CCT was not correlated with any strains in the cornea, ONH, or PPS. Conclusions: Our results suggested that an eye that experiences a larger shear strain in the cornea would likely experience a larger shear strain in its ONH and PPS at IOP elevations. The strong correlation between the cornea's and the ONH's shear response to IOP provides new insights and suggests a plausible explanation of the cornea's connection to glaucoma risk.


Assuntos
Córnea , Pressão Intraocular , Disco Óptico , Humanos , Disco Óptico/diagnóstico por imagem , Córnea/diagnóstico por imagem , Córnea/fisiologia , Pressão Intraocular/fisiologia , Fenômenos Biomecânicos/fisiologia , Idoso , Pessoa de Meia-Idade , Esclera/fisiologia , Esclera/diagnóstico por imagem , Masculino , Feminino , Glaucoma/fisiopatologia , Idoso de 80 Anos ou mais , Doadores de Tecidos , Adulto
12.
Lasers Med Sci ; 39(1): 136, 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38795228

RESUMO

PURPOSE: The goal of this study was to compare the settings and effectiveness of the original P3 and revised P3 probes for micropulse transscleral cyclophotocoagulation. METHODS: This retrospective cross sectional study includes a total of 56 patients with glaucoma who received micropulse transscleral cyclophotocoagulation. 32 patients received treatment with the original P3 probe and 24 received treatment with the revised P3 probe. Success was defined as a 20% reduction in intraocular pressure. Laser settings, pre-op and post-op intraocular pressures, and pre-op and post-op medications were assessed. RESULTS: A 20% IOP reduction was achieved in 50% of patients in the original probe vs. 58.3% in the revised probe at one month (P = 0.536) and 71.9% vs. 50% at three months (P = 0.094), respectively. The revised P3 probe used higher values of power (2500 mW vs. 2023 mW, P < 0.0001), total duration (217 s vs. 179 s, P < 0.0001), and energy (170 J vs. 113 J, P < 0.001). There was a significant decrease in IOP lowering meds with the original probe at one month (-0.9 +/- 1.5 vs. -0.0 +/- 0.7, P = 0.010), but this was not seen at three months. CONCLUSIONS: There is no significant difference in IOP lowering effect between probes despite the revised probe using higher total energy. The original probe may be associated with fewer medications at 1 month, but not at 3 months. Further studies with longer follow up are needed to optimize the treatment parameters in order to maximize effectiveness while limiting side effects.


Assuntos
Glaucoma , Pressão Intraocular , Fotocoagulação a Laser , Humanos , Estudos Retrospectivos , Feminino , Masculino , Estudos Transversais , Pessoa de Meia-Idade , Pressão Intraocular/fisiologia , Glaucoma/cirurgia , Fotocoagulação a Laser/métodos , Fotocoagulação a Laser/instrumentação , Idoso , Esclera/cirurgia , Resultado do Tratamento , Adulto , Corpo Ciliar/cirurgia , Idoso de 80 Anos ou mais
13.
Ophthalmic Physiol Opt ; 44(5): 867-875, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38699941

RESUMO

PURPOSE: The fit and optical performance of a scleral lens is affected by the alignment of the landing zone with the underlying ocular surface. The aim of this research was to quantify the effect of landing zone toricity upon scleral lens fitting characteristics (rotation and decentration) and optics (lens flexure) during short-term wear. METHODS: Scleral lenses with nominal landing zone toricities of 0, 100, 150 and 200 µm were worn in a randomised order by 10 young healthy participants (mean [SD] 24 [7] years) for 30 min, with other lens parameters held constant. Scleral toricity was quantified using a corneo-scleral profilometer, and lens flexure, rotation, and decentration were quantified using over-topography during lens wear. Repeated measures analyses were conducted as a function of landing zone toricity and residual scleral toricity (the difference between scleral and lens toricity) for eyes with 'low' magnitude scleral toricity (mean: 96 µm) and 'high' magnitude scleral toricity (mean: 319 µm). RESULTS: Toric landing zones significantly reduced lens flexure (by 0.37 [0.21] D, p < 0.05) and lens rotation (by 20 [24]°, p < 0.05) compared with a spherical landing zone. Horizontal and vertical lens decentration did not vary significantly with landing zone toricity. These trends for flexure, rotation, and decentration were also observed for eyes with 'low' and 'high' magnitude scleral toricity as a function of residual scleral toricity. CONCLUSION: Landing zones with 100-200 µm toricity significantly reduced lens flexure (by ~62%) and rotation (by ~77%) but not horizontal or vertical lens decentration, compared with a spherical landing zone, when controlling for other confounding variables. The incorporation of a toric landing zone, even for eyes with lower magnitude scleral toricity (~100 µm), may be beneficial, particularly for front surface optical designs.


Assuntos
Lentes de Contato , Refração Ocular , Esclera , Humanos , Masculino , Adulto Jovem , Adulto , Feminino , Refração Ocular/fisiologia , Ajuste de Prótese , Óptica e Fotônica , Topografia da Córnea , Acuidade Visual/fisiologia
14.
Sci Rep ; 14(1): 12508, 2024 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-38822021

RESUMO

Adult vertebrate cartilage is usually quiescent. Some vertebrates possess ocular scleral skeletons composed of cartilage or bone. The morphological characteristics of the spotted wolffish (Anarhichas minor) scleral skeleton have not been described. Here we assessed the scleral skeletons of cultured spotted wolffish, a globally threatened marine species. The healthy spotted wolffish we assessed had scleral skeletons with a low percentage of cells staining for the chondrogenesis marker sex-determining region Y-box (Sox) 9, but harboured a population of intraocular cells that co-express immunoglobulin M (IgM) and Sox9. Scleral skeletons of spotted wolffish with grossly observable eye abnormalities displayed a high degree of perochondrial activation as evidenced by cellular morphology and expression of proliferating cell nuclear antigen (PCNA) and phosphotyrosine. Cells staining for cluster of differentiation (CD) 45 and IgM accumulated around sites of active chondrogenesis, which contained cells that strongly expressed Sox9. The level of scleral chondrogenesis and the numbers of scleral cartilage PCNA positive cells increased with the temperature of the water in which spotted wolffish were cultured. Our results provide new knowledge of differing Sox9 spatial tissue expression patterns during chondrogenesis in normal control and ocular insult paradigms. Our work also provides evidence that spotted wolffish possess an inherent scleral chondrogenesis response that may be sensitive to temperature. This work also advances the fundamental knowledge of teleost ocular skeletal systems.


Assuntos
Condrogênese , Fatores de Transcrição SOX9 , Animais , Fatores de Transcrição SOX9/metabolismo , Esclera/metabolismo , Temperatura , Imunoglobulina M/metabolismo , Olho/metabolismo , Água/metabolismo , Antígeno Nuclear de Célula em Proliferação/metabolismo , Cartilagem/metabolismo
15.
Invest Ophthalmol Vis Sci ; 65(5): 4, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38691089

RESUMO

Purpose: To investigate the adhesion of Acanthamoeba to scleral contact lens (ScCL) surface according to lens shape. Methods: Two strains of A. polyphaga (CDC:V062 and ATCC 30461) and one clinical Acanthamoeba isolate, were inoculated onto five contact lens (CL): one first-generation silicone hydrogel (SHCL; lotrafilcon B; adhesion control) containing plasma surface treatment; two ScCL (fluorosilicone acrylate) one containing surface treatment composed of plasma and the other containing plasma with Hydra-PEG, and two CL designed with a flat shape having the same material and surface treatments of the ScCL. Trophozoites that adhered to the lens's surfaces were counted by inverted optical light microscopy. Possible alterations of the lens surface that could predispose amoeba adhesion and Acanthamoeba attached to these lens surfaces were evaluated by scanning electron microscopy (SEM). Results: All strains revealed greater adhesion to the ScCL when compared with the flat lenses (P < 0.001). The clinical isolate and the ATCC 30461 had a higher adhesion (P < 0.001) when compared with the CDC:V062. A rough texture was observed on the surface of the lenses that have been examined by SEM. Also, SEM revealed that the isolates had a rounded appearance on the surface of the ScCL in contrast with an elongated appearance on the surface of the silicone hydrogel. Conclusions: The findings revealed that the curved shape of the ScCL favors amoeba adhesion.


Assuntos
Acanthamoeba , Microscopia Eletrônica de Varredura , Acanthamoeba/fisiologia , Acanthamoeba/ultraestrutura , Esclera , Humanos , Lentes de Contato Hidrofílicas/parasitologia , Adesão Celular/fisiologia , Lentes de Contato/parasitologia , Trofozoítos/ultraestrutura , Trofozoítos/fisiologia , Hidrogéis , Animais
16.
Int J Pharm ; 658: 124195, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38703935

RESUMO

Microneedles (MN) have emerged as an innovative technology for drug delivery, offering a minimally invasive approach to administer therapeutic agents. Recent applications have included ocular drug delivery, requiring the manufacture of sub-millimeter needle arrays in a reproducible and reliable manner. The development of 3D printing technologies has facilitated the fabrication of MN via mold production, although there is a paucity of information available regarding how the printing parameters may influence crucial issues such as sharpness and penetration efficacy. In this study, we have developed and optimized a 3D-printed MN micro-mold using stereolithography (SLA) 3D printing to prepare a dissolving ocular MN patch. The effects of a range of parameters including aspect ratio, layer thickness, length, mold shape and printing orientation have been examined with regard to both architecture and printing accuracy of the MN micro-mold, while the effects of printing angle on needle fidelity was also examined for a range of basic shapes (conical, pyramidal and triangular pyramidal). Mechanical strength and in vitro penetration of the polymeric (PVP/PVA) MN patch produced from reverse molds fabricated using MN with a range of shapes and height, and aspect ratios were assessed, followed by ex vivo studies of penetration into excised scleral and corneal tissues. The optimization process identified the parameters required to produce MN with the sharpest tips and highest dimensional fidelity, while the ex vivo studies indicated that these optimized systems would penetrate the ocular tissue with minimal applied pressure, thereby allowing ease of patient self-administration.


Assuntos
Administração Oftálmica , Sistemas de Liberação de Medicamentos , Agulhas , Impressão Tridimensional , Estereolitografia , Animais , Microinjeções/métodos , Microinjeções/instrumentação , Córnea/metabolismo , Esclera , Suínos , Tecnologia Farmacêutica/métodos
17.
Exp Eye Res ; 244: 109917, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38697276

RESUMO

In glaucoma, scleral fibroblasts are exposed to IOP-associated mechanical strain and elevated TGFß levels. These stimuli, in turn, lead to scleral remodeling. Here, we examine the scleral fibroblast migratory and transcriptional response to these stimuli to better understand mechanisms of glaucomatous scleral remodeling. Human peripapillary scleral (PPS) fibroblasts were cultured on parallel grooves, treated with TGFß (2 ng/ml) in the presence of vehicle or TGFß signaling inhibitors, and exposed to uniaxial strain (1 Hz, 5%, 12-24 h). Axis of cellular orientation was determined at baseline, immediately following strain, and 24 h after strain cessation with 0° being completely aligned with grooves and 90° being perpendicular. Fibroblasts migration in-line and across grooves was assessed using a scratch assay. Transcriptional profiling of TGFß-treated fibroblasts with or without strain was performed by RT-qPCR and pERK, pSMAD2, and pSMAD3 levels were measured by immunoblot. Pre-strain alignment of TGFß-treated cells with grooves (6.2 ± 1.5°) was reduced after strain (21.7 ± 5.3°, p < 0.0001) and restored 24 h after strain cessation (9.5 ± 2.6°). ERK, FAK, and ALK5 inhibition prevented this reduction; however, ROCK, YAP, or SMAD3 inhibition did not. TGFß-induced myofibroblast markers were reduced by strain (αSMA, POSTN, ASPN, MLCK1). While TGFß-induced phosphorylation of ERK and SMAD2 was unaffected by cyclic strain, SMAD3 phosphorylation was reduced (p = 0.0004). Wound healing across grooves was enhanced by ROCK and SMAD3 inhibition but not ERK or ALK5 inhibition. These results provide insight into the mechanisms by which mechanical strain alters the cellular response to TGFß and the potential signaling pathways that underlie scleral remodeling.


Assuntos
Movimento Celular , Fibroblastos , Esclera , Estresse Mecânico , Fator de Crescimento Transformador beta , Humanos , Fibroblastos/metabolismo , Fibroblastos/efeitos dos fármacos , Células Cultivadas , Fator de Crescimento Transformador beta/farmacologia , Fator de Crescimento Transformador beta/metabolismo , Esclera/metabolismo , Transdução de Sinais , Reação em Cadeia da Polimerase em Tempo Real , Regulação da Expressão Gênica , Glaucoma/metabolismo , Glaucoma/patologia
18.
BMC Ophthalmol ; 24(1): 154, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594683

RESUMO

BACKGROUND: Intraocular lens (IOL) fixation is performed after intraoperative anterior or total vitrectomy. This study aimed to compare the intraoperative and postoperative complications of these two techniques. METHODS: This retrospective study included 235 eyes that underwent intrascleral fixation surgery at our hospital between July 2014 and January 2021. The eyes were classified into the anterior vitrectomy group (A-vit group; 134 eyes) and the pars plana vitrectomy group (PPV group; 101 eyes). The age, preoperative and postoperative best-corrected visual acuity, observation period, preoperative and postoperative intraocular pressure, and the incidence of intraoperative and postoperative complications were assessed. RESULTS: Intrascleral fixation was performed more frequently in the PPV group, and a significant difference was observed between the eyes with a history of vitrectomy and eyes with scleral buckles (p = 0.00041). In terms of the incidence of postoperative complications following intrascleral fixation, the incidence of low intraocular pressure postoperative was higher in the PPV group than that in the A-vit group, and a significant difference was observed between the two groups (p = 0.01). CONCLUSIONS: The visual outcome and complications following intrascleral fixation did not differ according to the extent of vitreous excision.


Assuntos
Lentes Intraoculares , Vitrectomia , Humanos , Vitrectomia/efeitos adversos , Vitrectomia/métodos , Implante de Lente Intraocular/métodos , Estudos Retrospectivos , Acuidade Visual , Esclera/cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/cirurgia
19.
Orphanet J Rare Dis ; 19(1): 176, 2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38678283

RESUMO

PURPOSE: Blue sclera is a characteristic and common clinical sign of Osteogenesis Imperfecta (OI). However, there is currently no widely accepted, objective method for assessing and grading blue sclera in individuals with OI. To address this medical need, this study is aimed to design and validate a new method called 'BLUES' (BLUe Eye Sclera) to objectively identify and quantify the blue color in the sclera of patients affected by OI. METHODS: Sixty-two patients affected by OI and 35 healthy controls were enrolled in the present prospective study, for a total of 194 eyes analyzed. In the 'BLUES' procedure, eye images from patients with OI and control subjects were analyzed to assess and grade the blue level of the sclera using Adobe Photoshop Software. The validation process then involved comparing the results obtained with the 'BLUES' procedure to the judgement of experienced ophthalmologists (JEO). A receiver-operating characteristic (ROC) curve analysis was used to examine the overall discriminatory power. The sensitivity and specificity levels and the Cohen's Kappa (K) indexes of 'BLUES' and 'JEO' were estimated versus the standard OI diagnosis. The K indexes of 'BLUES' versus 'JEO' were also evaluated. RESULTS: The optimal cut-off point of the scleral blue peak was calculated at 17%. Our findings demonstrated a sensitivity of 89% (CI95%: 0.835-0.945) and specificity of 87% (CI95%: 0.791-0.949) for the 'BLUES' procedure with an agreement versus the diagnosis of OI of 0.747. In comparison, the sensitivity and specificity of 'JEO' ranged from 89 to 94% and 77% to 100%, respectively, with an agreement ranging from 0.663 to 0.871 with the diagnosis of OI. The agreement between 'BLUES 'and 'JEO' evaluations ranged from 0.613 to 0.734. CONCLUSIONS: Our findings demonstrated an 89% sensitivity and an impressive 87% specificity of our method to analyze the blue sclera in OI. The results indicated high agreement with disease diagnosis and were consistent with evaluations by experienced ophthalmologists. The 'BLUES' procedure appears to be a simple, reliable and objective method for effectively identify and quantify the blue color of the sclera in OI.


Assuntos
Osteogênese Imperfeita , Esclera , Humanos , Osteogênese Imperfeita/patologia , Osteogênese Imperfeita/diagnóstico , Esclera/patologia , Feminino , Masculino , Estudos Prospectivos , Adolescente , Criança , Adulto , Adulto Jovem , Pré-Escolar , Curva ROC
20.
BMC Ophthalmol ; 24(1): 190, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658861

RESUMO

BACKGROUND: Ciliary body tumor is extremely rare and treatment is challenging. The aim of this study is to present our experience in treating this rare entity, especially large tumors with more than 5 clock hours of involvement, and to evaluate the surgical outcomes and complications of local resection via partial lamellar sclerouvectomy in four cases of ciliary body tumors in China. METHODS: Four patients with ciliary body tumors underwent partial lamellar sclerouvectomy between October 2019 and April 2023 in Shanghai General Hospital, China. Tumor features, histopathologic findings, complications, visual acuity, and surgical outcomes were reviewed at a mean follow-up of 20.8 months. RESULTS: Four patients with a mean age of 31.8 years were included in this study. The histopathological diagnosis was adenoma of non-pigmented ciliary epithelium (ANPCE), schwannoma, and multiple ciliary body pigment epithelial cysts. The mean largest tumor base diameter was 6.00 mm (range: 2.00-10.00) and the mean tumor thickness was 3.50 mm (range: 2.00-5.00). Preoperative complications included cataract in 3 (75%) eyes, lens dislocation in 2 (50%), and secondary glaucoma in 1 (25%). Temporary ocular hypotonia was observed in one case and no other postoperative complications were observed. At a mean follow-up of 20.8 months, the best corrected visual acuity increased in 3 eyes and was stable in 1 eye. Tumor recurrence was absent in all eyes. All patients were alive at the end of follow-up. CONCLUSIONS: Local tumor resection via PLSU is useful in the treatment of ciliary body tumors, including large tumors occupying more than five clock hours of pars plicata. Surgery-related complications were manageable with adequate preoperative assessment and careful operation during surgery.


Assuntos
Corpo Ciliar , Esclera , Neoplasias Uveais , Acuidade Visual , Adulto , Humanos , Corpo Ciliar/cirurgia , Corpo Ciliar/patologia , Seguimentos , Procedimentos Cirúrgicos Oftalmológicos/métodos , Estudos Retrospectivos , Esclera/cirurgia , Esclera/patologia , Neoplasias Uveais/cirurgia , Neoplasias Uveais/diagnóstico , Acuidade Visual/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...