Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74.612
Filtrar
1.
Mikrochim Acta ; 191(6): 332, 2024 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-38748375

RESUMO

Nifedipine (NIF), as one of the dihydropyridine calcium channel blockers, is widely used in the treatment of hypertension. However, misuse or ingestion of NIF can result in serious health issues such as myocardial infarction, arrhythmia, stroke, and even death. It is essential to design a reliable and sensitive detection method to monitor NIF. In this work, an innovative molecularly imprinted polymer dual-emission fluorescent sensor (CDs@PDA-MIPs) strategy was successfully designed for sensitive detection of NIF. The fluorescent intensity of the probe decreased with increasing NIF concentration, showing a satisfactory linear relationship within the range 1.0 × 10-6 M ~ 5.0 × 10-3 M. The LOD of NIF was 9.38 × 10-7 M (S/N = 3) in fluorescence detection. The application of the CDs@PDA-MIPs in actual samples such as urine and Qiangli Dingxuan tablets has been verified, with recovery ranging from 97.8 to 102.8% for NIF. Therefore, the fluorescent probe demonstrates great potential as a sensing system for detecting NIF.


Assuntos
Carbono , Dopamina , Corantes Fluorescentes , Limite de Detecção , Polímeros Molecularmente Impressos , Nifedipino , Pontos Quânticos , Espectrometria de Fluorescência , Pontos Quânticos/química , Nifedipino/química , Nifedipino/análise , Corantes Fluorescentes/química , Polímeros Molecularmente Impressos/química , Dopamina/urina , Dopamina/análise , Carbono/química , Espectrometria de Fluorescência/métodos , Humanos , Polimerização , Impressão Molecular , Comprimidos/análise
2.
Molecules ; 29(9)2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38731451

RESUMO

A novel second-generation blue fluorescent polyamidoamine dendrimer peripherally modified with sixteen 4-N,N-dimethylaninoethyloxy-1,8-naphthalimide units was synthesized. Its basic photophysical characteristics were investigated in organic solvents of different polarity. It was found that in these solvents, the dendrimer is colorless and emitted blue fluorescence with different intensities depending on their polarity. The effect of the pH of the medium on the fluorescence intensity was investigated and it was found that in the acidic medium, the fluorescence is intense and is quenched in the alkaline medium. The ability of the dendrimer to detect metal ions (Pb2+, Zn2+, Mg2+, Sn2+, Ba2+, Ni2+, Sn2+, Mn2+, Co2+, Fe3+, and Al3+) was also investigated, and it was found that in the presence of Fe3+, the fluorescent intensity was amplified more than 66 times. The antimicrobial activity of the new compound has been tested in vitro against Gram-positive B. cereus and Gram-negative P. aeruginosa. The tests were performed in the dark and after irradiation with visible light. The antimicrobial activity of the compound enhanced after light irradiation and B. cereus was found slightly more sensitive than P. aeruginosa. The increase in antimicrobial activity after light irradiation is due to the generation of singlet oxygen particles, which attack bacterial cell membranes.


Assuntos
Dendrímeros , Testes de Sensibilidade Microbiana , Naftalimidas , Poliaminas , Naftalimidas/química , Naftalimidas/farmacologia , Dendrímeros/química , Dendrímeros/farmacologia , Poliaminas/química , Poliaminas/farmacologia , Antibacterianos/farmacologia , Antibacterianos/química , Fluorescência , Pseudomonas aeruginosa/efeitos dos fármacos , Concentração de Íons de Hidrogênio , Bacillus cereus/efeitos dos fármacos , Luz , Corantes Fluorescentes/química , Espectrometria de Fluorescência
3.
Anal Methods ; 16(19): 3099-3108, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38695127

RESUMO

The CRISPR-Cas system has been found to be extremely sensitive and there is an urgent demand to extend its potential in bioassays. Herein, we developed a novel nanobiosensor to detect the human papillomavirus 16 genes (HPV-16 DNA), which is triggered by CRISPR-Cas12a to amplify the fluorescence signal by metal-enhanced fluorescence (CAMEF). Along with the changing of the fluorescence signal, the aggregation of the substrate of MEF also leads to a change in the color of the mixture solution, enabling dual signal detection with the fluorescence and the naked eye. Furthermore, the designed CAMEF probe was verified to detect the HPV-16 DNA accurately and reliably in biological samples. Triggered by the CRISPR system, the designed CAMEF probe allows quantitative detection of the HPV-16 DNA in the wide range of 10-500 pM. Owing to the MEF, the fluorescence signal of the CAMEF probe was significantly amplified with the detection limit as low as 1 pM. Besides, we can determine the concentration of HPV-16 DNA simply by the naked eye, which also drastically reduces the possibility of false-positive signals. Theoretically, the target ssDNA could be any strand of DNA obtained by designing the crRNA sequence in the CRISPR-Cas system. We believe that the designed CAMEF sensor can present a reliable approach for the accurate detection of low amounts of target ssDNA in complex biological samples.


Assuntos
Técnicas Biossensoriais , Sistemas CRISPR-Cas , Colorimetria , DNA Viral , Papillomavirus Humano 16 , Sistemas CRISPR-Cas/genética , Papillomavirus Humano 16/genética , Colorimetria/métodos , Humanos , DNA Viral/análise , DNA Viral/genética , Técnicas Biossensoriais/métodos , Limite de Detecção , Fluorescência , Corantes Fluorescentes/química , Espectrometria de Fluorescência/métodos
4.
Anal Methods ; 16(19): 3125-3130, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38700061

RESUMO

A new fluorescence sensing approach has been proposed for the precise determination of the anti-cancer drug oxaliplatin (Oxal-Pt). This method entails synthesizing blue-emitting copper nanoclusters (CuNCs) functionalized with bovine serum albumin (BSA) as the stabilizing agent. Upon excitation at 360 nm, the resultant probe exhibits emission at 460 nm. Notably, the fluorescence response of BSA@CuNCs substantially increases upon incubation with Oxal-Pt due to multiple binding interactions between the drug and the fluorescent probe. These interactions involve hydrogen bonding, hydrophobic interaction, and the high affinity between the SH groups (cysteine residues of BSA) and platinum (in Oxal-Pt). Consequently, this interaction induces aggregation-induced emission enhancement (AIEE) of BSA@CuNCs. The probe demonstrates a broad response range from 0.08 to 140.0 µM, along with a low detection limit of 20.0 nM, determined based on a signal-to-noise ratio of 3. Furthermore, the probe effectively detects Oxal-Pt in injections, human serum, and urine samples, yielding acceptable results. This study represents a significant advancement in the development of a straightforward and efficient sensor for monitoring platinum-containing anti-cancer drugs during chemotherapy.


Assuntos
Antineoplásicos , Cobre , Monitoramento de Medicamentos , Corantes Fluorescentes , Oxaliplatina , Soroalbumina Bovina , Espectrometria de Fluorescência , Oxaliplatina/química , Soroalbumina Bovina/química , Cobre/química , Humanos , Antineoplásicos/química , Monitoramento de Medicamentos/métodos , Espectrometria de Fluorescência/métodos , Corantes Fluorescentes/química , Nanopartículas Metálicas/química , Animais , Limite de Detecção , Neoplasias/tratamento farmacológico , Bovinos
5.
Spectrochim Acta A Mol Biomol Spectrosc ; 316: 124317, 2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-38692102

RESUMO

Nitroxyl (HNO), the single-electron reduction product of nitric oxide (NO), has attracted great interest in the treatment of congestive heart failure in clinical trials. In this paper, we describe the first coumarin-based compound N-hydroxy-2-oxo-2H-chromene-6-sulfonamide (CD1) as a dualfunctional HNO donor, which can release both an HNO signaling molecule and a fluorescent reporter. Under physiological conditions (pH 7.4 and 37 °C), the CD1 HNO donor can readily decompose with a half-life of ∼90 min. The corresponding stoichiometry HNO from the CD1 donor was confirmed using both Vitamin B12 and phosphine compound traps. In addition to HNO releasing, specifically, the degradation product 2-oxo-2H-chromene-6-sulfinate (CS1) was generated as a fluorescent marker during the decomposition. Therefore, the HNO amount released in situ can be accurately monitored through fluorescence generation. As compared to the CD1 donor, the fluorescence intensity increased by about 4.9-fold. The concentration limit of detection of HNO releasing was determined to be ∼0.13 µM according to the fluorescence generation of CS1 at physiological conditions. Moreover, the bioimaging of the CD1 donor was demonstrated in the cell culture of HeLa cells, where the intracellular fluorescence signals were observed, inferring the site of HNO release. Finally, we anticipate that this novel coumarin-based CD1 donor opens a new platform for exploring the biology of HNO.


Assuntos
Cumarínicos , Corantes Fluorescentes , Óxidos de Nitrogênio , Cumarínicos/química , Humanos , Corantes Fluorescentes/química , Óxidos de Nitrogênio/química , Óxidos de Nitrogênio/análise , Espectrometria de Fluorescência , Células HeLa
6.
Spectrochim Acta A Mol Biomol Spectrosc ; 316: 124349, 2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-38692107

RESUMO

Fluorine (F) is a pivotal element in the formation of human dental and skeletal tissues, and the consumption of water and tea constitutes a significant source of fluoride intake. However, prolonged ingestion of water and tea with excessive fluoride content can lead to fluorosis, which poses a serious health hazard. In this manuscript, a novel turn-on fluorescent probe DCF synthesized by bis-coumarin and tert-butyldiphenylsilane (TBDPS) was introduced for detecting F- in potable water and tea infusions. By leveraging the unique chemical affinity between fluoride and silicon, F- triggers the silicon-oxygen bond cleavage in DCF, culminating in a conspicuous emission of yellow fluorescence. Validated through a succession of optical tests, this probe exhibits remarkable advantages in terms of superior selectivity, a low detection limit, a large Stokes shift, and robust interference resistance when detecting inorganic fluoride. Moreover, it can serve as portable test strips for on-site real-time identification and quantitative analysis of F-. Furthermore, the application of DCF for in-situ monitoring and imaging of F- in zebrafish and soybean root tissues proved its significant value for F- detection in both animal and plant systems. This probe potentially functions as an efficient instrument for delving into the toxic mechanisms of fluoride in physiological processes.


Assuntos
Cumarínicos , Corantes Fluorescentes , Chá , Peixe-Zebra , Corantes Fluorescentes/química , Animais , Cumarínicos/química , Chá/química , Água Potável/análise , Espectrometria de Fluorescência/métodos , Flúor/análise , Flúor/química , Fluoretos/análise , Glycine max/química , Limite de Detecção , Imagem Óptica/métodos
7.
Spectrochim Acta A Mol Biomol Spectrosc ; 316: 124357, 2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-38692110

RESUMO

This study described the preparation of an azide covalent organic framework-embedded molecularly imprinted polymers (COFs(azide)@MIPs) platform for urea adsorption and indirect ethyl carbamate (EC) removal from Chinese yellow rice wine (Huangjiu). By modifying the pore surface of COFs using the copper-catalyzed azide-alkyne cycloaddition (CuAAC) reaction, COFs(azide) with a high fluorescence quantum yield and particular recognition ability were inventively produced. In order to selectively trap urea, the COFs(azide) were encased in an imprinted shell layer via imprinting technology. With a detection limit (LOD) of 0.016 µg L-1 (R2 = 0.9874), the COFs(azides)@MIPs demonstrated a good linear relationship with urea in the linear range of 0-5 µg L-1. Using real Huangjiu samples, the spiking recovery trials showed the viability of this sensing platform with recoveries ranging from 88.44 % to 109.26 % and an RSD of less than 3.40 %. The Huangjiu processing model system achieved 38.93 % EC reduction by COFs(azides)@MIPs. This research will open up new avenues for the treatment of health problems associated with fermented alcoholic beverages, particularly Huangjiu, while also capturing and removing hazards coming from food.


Assuntos
Polímeros Molecularmente Impressos , Ureia , Uretana , Vinho , Uretana/análise , Uretana/química , Polímeros Molecularmente Impressos/química , Ureia/análise , Ureia/química , Vinho/análise , Espectrometria de Fluorescência/métodos , Azidas/química , Limite de Detecção , Adsorção , Estruturas Metalorgânicas/química , Impressão Molecular/métodos
8.
Int J Mol Sci ; 25(9)2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38731924

RESUMO

Förster resonance energy transfer (FRET) spectrometry is a method for determining the quaternary structure of protein oligomers from distributions of FRET efficiencies that are drawn from pixels of fluorescence images of cells expressing the proteins of interest. FRET spectrometry protocols currently rely on obtaining spectrally resolved fluorescence data from intensity-based experiments. Another imaging method, fluorescence lifetime imaging microscopy (FLIM), is a widely used alternative to compute FRET efficiencies for each pixel in an image from the reduction of the fluorescence lifetime of the donors caused by FRET. In FLIM studies of oligomers with different proportions of donors and acceptors, the donor lifetimes may be obtained by fitting the temporally resolved fluorescence decay data with a predetermined number of exponential decay curves. However, this requires knowledge of the number and the relative arrangement of the fluorescent proteins in the sample, which is precisely the goal of FRET spectrometry, thus creating a conundrum that has prevented users of FLIM instruments from performing FRET spectrometry. Here, we describe an attempt to implement FRET spectrometry on temporally resolved fluorescence microscopes by using an integration-based method of computing the FRET efficiency from fluorescence decay curves. This method, which we dubbed time-integrated FRET (or tiFRET), was tested on oligomeric fluorescent protein constructs expressed in the cytoplasm of living cells. The present results show that tiFRET is a promising way of implementing FRET spectrometry and suggest potential instrument adjustments for increasing accuracy and resolution in this kind of study.


Assuntos
Estudos de Viabilidade , Transferência Ressonante de Energia de Fluorescência , Microscopia de Fluorescência , Transferência Ressonante de Energia de Fluorescência/métodos , Microscopia de Fluorescência/métodos , Humanos , Proteínas de Fluorescência Verde/metabolismo , Proteínas de Fluorescência Verde/química , Espectrometria de Fluorescência/métodos , Proteínas Luminescentes/química , Proteínas Luminescentes/metabolismo , Fluorescência
9.
J Photochem Photobiol B ; 255: 112927, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38701631

RESUMO

Since the mechanism underlying real-time acquisition of mechanical strength during laser-induced skin wound fusion remains unclear, and collagen is the primary constituent of skin tissue, this study investigates the structural and mechanical alterations in collagen at temperatures ranging from 40 °C to 60 °C using various spectroscopic techniques and molecular dynamics calculations. The COMSOL Multiphysics coupling is employed to simulate the three-dimensional temperature field, stress-strain relationship, and light intensity distribution in the laser thermal affected zone of skin wounds during dual-beam laser welding process. Raman spectroscopy, synchronous fluorescence spectroscopy and circular dichroism measurement results confirm that laser energy activates biological activity in residues, leading to a transformation in the originally fractured structure of collagen protein for enhanced mechanical strength. Molecular dynamics simulations reveal that stable hydrogen bonds form at amino acid residues within the central region of collagen protein when the overall temperature peak around the wound reaches 60 °C, thereby providing stability to previously fractured skin incisions and imparting instantaneous strength. However, under a 55 °C system, Type I collagen ensures macrostructural stability while activating biological properties at amino acid bases to promote wound healing function; this finding aligns with experimental analysis results. The COMSOL simulation outcomes also correspond well with macroscopic morphology after laser welding samples, confirming that by maintaining temperatures between 55 °C-60 °C during laser welding of skin incisions not only can certain instantaneous mechanical strength be achieved but irreversible thermal damage can also be effectively controlled. It is anticipated that these findings will provide valuable insights into understanding the healing mechanism for laser-welded skin wounds.


Assuntos
Colágeno , Lasers , Simulação de Dinâmica Molecular , Pele , Análise Espectral Raman , Pele/química , Pele/efeitos da radiação , Colágeno/química , Colágeno/metabolismo , Cicatrização , Ligação de Hidrogênio , Análise de Elementos Finitos , Animais , Dicroísmo Circular , Temperatura , Espectrometria de Fluorescência
10.
Mikrochim Acta ; 191(5): 293, 2024 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-38691169

RESUMO

To address the need for facile, rapid detection of pathogens in water supplies, a fluorescent sensing array platform based on antibiotic-stabilized metal nanoclusters was developed for the multiplex detection of pathogens. Using five common antibiotics, eight different nanoclusters (NCs) were synthesized including ampicillin stabilized copper NCs, cefepime stabilized gold and copper NCs, kanamycin stabilized gold and copper NCs, lysozyme stabilized gold NCs, and vancomycin stabilized gold/silver and copper NCs. Based on the different interaction of each NC with the bacteria strains, unique patterns were generated. Various machine learning algorithms were employed for pattern discernment, among which the artificial neural networks proved to have the highest performance, with an accuracy of 100%. The developed prediction model performed well on an independent test dataset and on real samples gathered from drinking water, tap water and the Anzali Lagoon water, with prediction accuracy of 96.88% and 95.14%, respectively. This work demonstrates how generic antibiotics can be implemented for NC synthesis and used as recognition elements for pathogen detection. Furthermore, it displays how merging machine learning techniques can elevate sensitivity of analytical devices.


Assuntos
Antibacterianos , Cobre , Ouro , Nanopartículas Metálicas , Prata , Nanopartículas Metálicas/química , Antibacterianos/análise , Antibacterianos/química , Ouro/química , Cobre/química , Prata/química , Água Potável/microbiologia , Água Potável/análise , Redes Neurais de Computação , Espectrometria de Fluorescência/métodos , Aprendizado de Máquina , Bactérias/isolamento & purificação , Corantes Fluorescentes/química , Vancomicina/química , Microbiologia da Água , Canamicina/análise
11.
Cell Rep Methods ; 4(5): 100774, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38749444

RESUMO

We present methods for making and testing the membrane biophysics of model lipid droplets (LDs). Methods are described for imaging LDs ranging in size from 0.1 to 40 µm in diameter with high-resolution microscopy and spectroscopy. With known LD compositions, membrane binding, sorting, diffusion, and tension were measured via fluorescence correlation spectroscopy (FCS), fluorescence recovery after photobleaching (FRAP), fluorescence lifetime imaging microscopy (FLIM), atomic force microscopy (AFM), and imaging flow cytometry. Additionally, a custom, small-volume pendant droplet tensiometer is described and used to measure the association of phospholipids to the LD surface. These complementary, cross-validating methods of measuring LD membrane behavior reveal the interplay of biophysical processes on lipid droplet monolayers.


Assuntos
Gotículas Lipídicas , Gotículas Lipídicas/metabolismo , Gotículas Lipídicas/química , Microscopia de Força Atômica/métodos , Microscopia de Fluorescência/métodos , Recuperação de Fluorescência Após Fotodegradação/métodos , Humanos , Citometria de Fluxo/métodos , Espectrometria de Fluorescência/métodos
12.
Luminescence ; 39(5): e4765, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38769927

RESUMO

Isovitexin is a main natural flavonoid component in various plants. Currently, the inhibitory effect of isovitexin on pancreatic lipase (PL) and its mechanism have not been elucidated yet. In the present study, we investigated the inhibitory effect of isovitexin on PL, as well as its interaction mechanism, using enzyme inhibition methods, spectroscopic analysis, and molecular simulations. Results showed that isovitexin possessed significant PL inhibitory activity, with IC50 values of 0.26 ± 0.02 mM. The interaction between isovitexin and PL was dominated by static quenching, and mainly through hydrogen bonding and hydrophobic interaction forces. Analysis of fluorescence spectroscopy confirmed that isovitexin binding altered the conformation of the PL. Circular dichroism (CD) spectrum indicated that isovitexin altered the secondary structure of PL by decreasing the α-helix content and increasing the ß-fold content. Molecular simulations further characterize the conformational changes produced by the interaction between isovitexin with PL. The performed study may provide a new insight into the inhibitory mechanism of isovitexin as a novel PL inhibitor.


Assuntos
Apigenina , Dicroísmo Circular , Inibidores Enzimáticos , Lipase , Pâncreas , Espectrometria de Fluorescência , Lipase/antagonistas & inibidores , Lipase/metabolismo , Lipase/química , Pâncreas/enzimologia , Inibidores Enzimáticos/farmacologia , Inibidores Enzimáticos/química , Apigenina/química , Apigenina/farmacologia , Animais
13.
Luminescence ; 39(5): e4774, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38757441

RESUMO

One of the most common features of many different clinical conditions is pain; hence, there is a crucial need for eliminating or reducing it to a tolerable level to retrieve physical, psychological and social functioning. A first derivative synchronous spectrofluorimetry technique is proposed for the simultaneous determination of celecoxib and tramadol HCl, a recent coformulation authorized for treating acute pain in adults. The method includes using synchronous spectrofluorimetry at ∆λ = 80 nm where tramadol HCl was determined using first derivative technique at λ = 230.2 nm, while celecoxib was determined at λ = 288.24 nm. The proposed method was successfully applied to their co-formulated dosage forms in addition to spiked human plasma and validated in agreement with the guidelines of the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH). The linear ranges were found to be 0.50-5.0 and 0.15-0.50, the limits of detection to be 0.088 and 0.011 and the limits of quantification to be 0.266 and 0.032 µg/ml for celecoxib and tramadol, respectively. Statistical analysis revealed no significant difference when compared with previously reported methods as evidenced by the values of the variance ratio F-test and Student t-test. The proposed method was successfully applied to commercial dosage forms and spiked human samples. Moreover, the greenness of the proposed method was investigated based on the analytical eco-scale approach, with the results showing an excellent green scale with a score of 95.


Assuntos
Celecoxib , Espectrometria de Fluorescência , Tramadol , Celecoxib/sangue , Celecoxib/análise , Tramadol/sangue , Tramadol/análise , Humanos , Espectrometria de Fluorescência/métodos , Comprimidos
14.
Luminescence ; 39(5): e4773, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38757733

RESUMO

Two Schiff base probes (S1 and S2) were prepared and synthesized by incorporating thienopyrimidine into salicylaldehyde or 3-ethoxysalicylaldehyde individually, with the aim of detecting Ga3+ and Pd2+ sequentially. Upon chelation with Ga3+, S1 and S2 exhibited fluorescence enhancement in DMSO/H2O buffer. Both S1-Ga3+ and S2-Ga3+ were quenched by Pd2+. The limit of detection for S1 in response to Ga3+ and Pd2+ was 2.86 × 10-7 and 4.4 × 10-9 M, respectively. For S2, the limit of detection for Ga3+ and Pd2+ was 4.15 × 10-8 and 3.0 × 10-9 M, respectively. Furthermore, the complexation ratios of both S1 and S2 with Ga3+ and Pd2+ were determined to be 1:2 through Job's plots, ESI-MS analysis, and theoretical calculations. Two molecular logic gates were constructed, leveraging the response behaviors of S1 and S2. Moreover, the potential utility of S1 and S2 for monitoring Ga3+ and Pd2+ in domestic water was verified.


Assuntos
Corantes Fluorescentes , Gálio , Paládio , Pirimidinas , Bases de Schiff , Bases de Schiff/química , Paládio/química , Pirimidinas/química , Pirimidinas/análise , Gálio/química , Corantes Fluorescentes/química , Corantes Fluorescentes/síntese química , Espectrometria de Fluorescência , Estrutura Molecular
15.
PLoS One ; 19(5): e0301779, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38748689

RESUMO

Southern leaf blight (SLB) is a foliar disease caused by the fungus Cochliobolus heterostrophus infecting maize plants in humid, warm weather conditions. SLB causes production losses to corn producers in different regions of the world such as Latin America, Europe, India, and Africa. In this paper, we demonstrate a non-destructive method to quantify the signs of fungal infection in SLB-infected corn plants using a deep UV (DUV) fluorescence spectrometer, with a 248.6 nm excitation wavelength, to acquire the emission spectra of healthy and SLB-infected corn leaves. Fluorescence emission spectra of healthy and diseased leaves were used to train an Autoencoder (AE) anomaly detection algorithm-an unsupervised machine learning model-to quantify the phenotype associated with SLB-infected leaves. For all samples, the signature of corn leaves consisted of two prominent peaks around 450 nm and 325 nm. However, SLB-infected leaves showed a higher response at 325 nm compared to healthy leaves, which was correlated to the presence of C. heterostrophus based on disease severity ratings from Visual Scores (VS). Specifically, we observed a linear inverse relationship between the AE error and the VS (R2 = 0.94 and RMSE = 0.935). With improved hardware, this method may enable improved quantification of SLB infection versus visual scoring based on e.g., fungal spore concentration per unit area and spatial localization.


Assuntos
Ascomicetos , Doenças das Plantas , Folhas de Planta , Zea mays , Zea mays/microbiologia , Doenças das Plantas/microbiologia , Folhas de Planta/microbiologia , Espectrometria de Fluorescência/métodos
16.
Anal Bioanal Chem ; 416(14): 3295-3303, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38696128

RESUMO

Thiabendazole, a widely used broad-spectrum fungicide in agriculture, poses risks to human health. To monitor its presence in water, we propose a fluorescent aptasensor utilizing Escherichia coli exonuclease I (Exo I). The findings demonstrate a linear correlation between thiabendazole concentrations and digestion percentage, with a detection limit (LOD) exceeding 1 µM and a determination coefficient (R2) of 0.959. This aptamer-based fluorescence spectroscopy detection system holds promise for a rapid, specific, and sensitive analysis of thiabendazole in environmental waters and food matrices.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Limite de Detecção , Espectrometria de Fluorescência , Tiabendazol , Tiabendazol/análise , Aptâmeros de Nucleotídeos/química , Espectrometria de Fluorescência/métodos , Técnicas Biossensoriais/métodos , Fungicidas Industriais/análise , Exodesoxirribonucleases/metabolismo , Exodesoxirribonucleases/química , Escherichia coli , Poluentes Químicos da Água/análise , Corantes Fluorescentes/química
17.
Klin Onkol ; 38(2): 102-109, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38697818

RESUMO

BACKGROUND: Endometrial carcinoma (EC) is the most common cancer of the female reproductive tract in developed countries. The prognosis and 5-year survival rates are closely tied to the stage diagnosis. Current routine diagnostic methods of EC are either lacking specificity or are uncomfortable, invasive and painful for the patient. As of now, the gold diagnostic standard is endometrial biopsy. Early and non-invasive diagnosis of EC requires the identification of new biomarkers of disease and a screening test applicable to routine laboratory diagnostics. The application of untargeted metabolomics combined with artificial intelligence and biostatistics tools has the potential to qualitatively and quantitatively represent the metabolome, but its introduction into routine diagnostics is currently unrealistic due to the financial, time and interpretation challenges. Fluorescence spectral analysis of body fluids utilizes autofluorescence of certain metabolites to define the composition of the metabolome under physiological conditions. PURPOSE: This review highlights the potential of fluorescence spectroscopy in the early detection of EC. Data obtained by three-dimensional fluorescence spectroscopy define the quantitative and qualitative composition of the complex fluorescent metabolome and are useful for identifying biochemical metabolic changes associated with endometrial carcinogenesis. Autofluorescence of biological fluids has the prospect of providing new molecular markers of EC. By integrating machine learning and artificial intelligence algorithms in the data analysis of the fluorescent metabolome, this technique has great potential to be implemented in routine laboratory diagnostics.


Assuntos
Líquidos Corporais , Neoplasias do Endométrio , Humanos , Neoplasias do Endométrio/diagnóstico , Feminino , Líquidos Corporais/química , Biomarcadores Tumorais/análise , Espectrometria de Fluorescência/métodos , Detecção Precoce de Câncer/métodos , Metabolômica/métodos , Imagem Óptica , Inteligência Artificial
18.
ACS Appl Bio Mater ; 7(5): 3460-3468, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38703374

RESUMO

Trimethylamine N-oxide (TMAO), a molecule produced by the microbiota, has been associated with human health and illness. Its early discovery in body fluids may affect our understanding of the pathophysiology and treatment of many illnesses. Therefore, our knowledge of the pathophysiology and diagnostics of disorders associated with TMAO might be enhanced by the creation of dependable and fast methods for TMAO detection. Therefore, we developed a fluorescent probe for detecting TMAO utilizing an on-off-on strategy. Bovine serum albumin (BSA)@AuNCs luminescence is effectively quenched by Mo4+ because BSA@AuNCs and Mo4+ have a strong binding relationship. Mo4+ ions can substantially decrease the emission intensity of gold nanoclusters by establishing a BSA@AuNCs-Mo system. Then, the luminescence of BSA@AuNCs was restored due to the interaction between Mo4+ and TMAO. A significant linear relationship was seen between the emission intensity and TMAO concentration within the 0-201 µM range, with a detection limit of 1.532 µM. Additionally, the method can measure TMAO in blood and urine samples.


Assuntos
Corantes Fluorescentes , Ouro , Teste de Materiais , Nanopartículas Metálicas , Metilaminas , Tamanho da Partícula , Soroalbumina Bovina , Metilaminas/química , Ouro/química , Soroalbumina Bovina/química , Nanopartículas Metálicas/química , Humanos , Corantes Fluorescentes/química , Materiais Biocompatíveis/química , Bovinos , Animais , Fluorescência , Espectrometria de Fluorescência , Estrutura Molecular
19.
Dalton Trans ; 53(20): 8812-8822, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38716578

RESUMO

The increasing utilization of hydrazine and its derivatives across diverse sectors highlights the pressing need for efficient detection methods to safeguard human health and the environment. Likewise, nicardipine, a widely used medication for heart diseases, necessitates accurate sensing techniques for clinical research and therapeutic monitoring. Here, we propose a novel approach using a naphthalimide-functionalized Zr-MOF as a fluorometric probe capable of detecting both hydrazine and nicardipine in aqueous medium. Our designed probe exhibited a significant 31-fold increase in fluorescence intensity upon interaction with hydrazine. At the same time, nicardipine induced 86% fluorescence quenching with an exceptionally rapid response time (100 s for hydrazine and 5 s for nicardipine). The designed probe has the ability to detect both analytes at nanomolar concentrations (LOD for hydrazine is 1.11 nM while that for nicardipine is 9.6 nM). Investigation across various wastewater samples and pH conditions further validated its practical utility. The mechanism behind fluorometric sensing of nicardipine was thoroughly investigated using modern instrumentation. Our study presents a versatile and effective approach for detecting hydrazine and nicardipine, addressing crucial needs in both industrial and biomedical contexts.


Assuntos
Anti-Hipertensivos , Hidrazinas , Estruturas Metalorgânicas , Naftalimidas , Nicardipino , Hidrazinas/análise , Hidrazinas/química , Nicardipino/análise , Naftalimidas/química , Estruturas Metalorgânicas/química , Anti-Hipertensivos/análise , Corantes Fluorescentes/química , Estrutura Molecular , Espectrometria de Fluorescência
20.
Luminescence ; 39(5): e4752, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38697778

RESUMO

Prucalopride (PCD), is a modern medication approved by the United States in 2018 to alleviate constipation caused by motility issues. PCD demonstrates a strong affinity and selectivity toward the 5-HT4 receptor. The study here introduces a feasible, direct, non-extractive, and affordable pathway for PCD analytical tracking. The fluorimetric study is based on the on-off effect on the emission amplitude of fluorone-based dye (pyrosin B). In a one-pot experiment, the complex between PCD and pyrosin B is formed instantly in an acidic medium. Correlation between decreased pyrosin B emission and PCD concentrations provides a linear calibration plot from 50 to 900 ng/mL. PCD-dye complex system affecting variables were meticulously tuned. The values of the estimated limit of quantitation and limit of detection for the current methodology were 47.5 and 15.7 ng/mL, respectively. Conformity of the strategy validity was achieved by a comprehensive study of the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use criteria. The method was convincingly applied for PCD assay in tablets and content uniformity investigation. Furthermore, PCD tracking in the spiked biological fluid was applied. Finally, the method uses distilled water as dispersing medium which rise accommodation with the green chemistry principle.


Assuntos
Benzofuranos , Corantes Fluorescentes , Benzofuranos/química , Benzofuranos/análise , Corantes Fluorescentes/química , Humanos , Espectrometria de Fluorescência , Estrutura Molecular , Limite de Detecção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...