Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23.984
Filtrar
1.
BMC Pulm Med ; 24(1): 230, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38730359

RESUMO

BACKGROUND: Spirofy™ is India's first portable, pneumotach flow-sensor-based digital spirometer developed to diagnose asthma and chronic obstructive pulmonary disease (COPD). In this study, we compared the performance of the Spirofy™ device with that of the Vitalograph Alpha Touch™ spirometer in measuring the lung capacities of healthy individuals, asthmatics, and COPD patients. We also assessed the inter-device variability between two Spirofy™ devices. METHODS: In a randomized, three-way crossover, open-label study, we measured the differences in forced expiratory volume in the first second (FEV1) and forced vital capacity (FVC) between the Spirofy™ and Vitalograph Alpha Touch™ spirometers. A proportion of the FEV1/FVC ratio distribution of < 0.7 was used to compare the diagnostic accuracies of the Spirofy™ with Vitalograph™ Alpha Touch™ spirometers. RESULTS: Ninety subjects participated in this study. The mean ± SD FVC values obtained from the Spirofy™ 1, Spirofy™ 2, and Vitalograph Alpha Touch™ devices were 2.60 ± 1.05 L, 2.64 ± 1.04 L, and 2.67 ± 1.04 L, respectively. The mean ± SD FEV1 values obtained from the Spirofy™ 1, Spirofy™ 2, and Vitalograph Alpha Touch™ devices were 1.87 ± 0.92 (L), 1.88 ± 0.92 (L), and 1.93 ± 0.93 (L), respectively. A significant positive correlation was found between the FVC and FEV1 values recorded by Vitalograph Alpha Touch™, Spirofy™ 1, and Spirofy™ 2. As compared to Vitalograph Alpha Touch™, the Spirofy™ device showed good sensitivity (97%), specificity (90%), and overall accuracy (93.3%) at an FEV1/FVC ratio < 0.7. No inter-device variability was observed between the two Spirofy™ devices. CONCLUSION: Spirofy™ is a portable and easy-to-use device and is as accurate as the standard Vitalograph Alpha Touch™ spirometer for the diagnosis of COPD and asthma. TRIAL REGISTRATION: CTRI/2021/09/036492 (Clinical Trials Registry - India).


Assuntos
Asma , Estudos Cross-Over , Doença Pulmonar Obstrutiva Crônica , Espirometria , Humanos , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Asma/diagnóstico , Asma/fisiopatologia , Masculino , Pessoa de Meia-Idade , Espirometria/instrumentação , Feminino , Adulto , Volume Expiratório Forçado , Capacidade Vital , Idoso , Índia , Adulto Jovem
2.
BMJ Open Respir Res ; 11(1)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38697675

RESUMO

BACKGROUND: Methods used to assess ventilation heterogeneity through inert gas washout have been standardised and showed high sensitivity in diagnosing many respiratory diseases. We hypothesised that nitrogen single or multiple breath washout tests, respectively nitrogen single breath washout (N2SBW) and nitrogen multiple breath washout (N2MBW), may be pathological in patients with clinical suspicion of asthma but normal spirometry. Our aim was to assess whether N2SBW and N2MBW are associated with methacholine challenge test (MCT) results in this population. We also postulated that an alteration in SIII at N2SBW could be detected before the 20% fall of forced expiratory volume in the first second (FEV1) in MCT. STUDY DESIGN AND METHODS: This prospective, observational, single-centre study included patients with suspicion of asthma with normal spirometry. Patients completed questionnaires on symptoms and health-related quality-of-life and underwent the following lung function tests: N2SBW (SIII), N2MBW (Lung clearance index (LCI), Scond, Sacin), MCT (FEV1 and sGeff) as well as N2SBW between each methacholine dose. RESULTS: 182 patients were screened and 106 were included in the study, with mean age of 41.8±14 years. The majority were never-smokers (58%) and women (61%). MCT was abnormal in 48% of participants, N2SBW was pathological in 10.6% at baseline and N2MBW abnormality ranged widely (LCI 81%, Scond 18%, Sacin 43%). The dose response rate of the MCT showed weak to moderate correlation with the subsequent N2SBW measurements during the provocation phases (ρ 0.34-0.50) but no correlation with N2MBW. CONCLUSIONS: Both MCT and N2 washout tests are frequently pathological in patients with suspicion of asthma with normal spirometry. The weak association and lack of concordance across the tests highlight that they reflect different but not interchangeable pathological pathways of the disease.


Assuntos
Asma , Testes Respiratórios , Testes de Provocação Brônquica , Cloreto de Metacolina , Nitrogênio , Espirometria , Humanos , Asma/diagnóstico , Asma/fisiopatologia , Cloreto de Metacolina/administração & dosagem , Feminino , Masculino , Estudos Prospectivos , Adulto , Testes Respiratórios/métodos , Pessoa de Meia-Idade , Nitrogênio/análise , Testes de Provocação Brônquica/métodos , Volume Expiratório Forçado , Testes de Função Respiratória/métodos , Pulmão/fisiopatologia , Broncoconstritores/administração & dosagem
4.
BMJ Open Respir Res ; 11(1)2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38719501

RESUMO

BACKGROUND: It has been known that smoking and various lung diseases including lung cancer can cause lung function impairment. However, the impact of different types of lung function impairments, such as preserved ratio impaired spirometry (PRISm) and airflow obstruction (AO), on the incidence and mortality of lung cancer in both general and never-smoker populations remains unclear. We wished to examine the effect of lung function impairments on lung cancer risks. METHODS: This was a retrospective cohort study (1 January 1994 to 31 December 2017) of individuals from a health surveillance programme in Taiwan who underwent baseline spirometry tests at the entry point. PRISm was defined as an FEV1/FVC (forced expiratory volume in 1 s/forced vital capacity) ratio >0.7 and FEV1 <0.8, while AO was defined as an FEV1/FVC ratio <0.7. Cox proportional hazards models and cubic spline curves were used to examine the associations between lung function impairments and lung cancer risks. RESULTS: The study included 461,183 individuals, of whom 14.3% had PRISm and 7.9% had AO. A total of 4038 cases of lung cancer and 3314 lung cancer-related deaths were identified during the 23 years of follow-up. Individuals with PRISm and AO exhibited a higher risk of lung cancer incidence and mortality compared with those with normal lung function. The adjusted HRs and 95% CIs were 1.14 (1.03 to 1.26) and 1.23 (1.10 to 1.37) in the overall cohort, and 1.08 (0.93 to 1.24), and 1.23 (1.05 to 1.45) in the never-smoker cohort. The risks of both developing and dying of lung cancer increased with the severity levels of lung function impairments and lower FEV1 values. CONCLUSION: Impaired lung function is associated with increased risks of developing lung cancer and subsequent mortality. The study highlights the importance of considering lung function in lung cancer screening for better candidate selection.


Assuntos
Neoplasias Pulmonares , Espirometria , Humanos , Neoplasias Pulmonares/epidemiologia , Neoplasias Pulmonares/mortalidade , Masculino , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Taiwan/epidemiologia , Adulto , Incidência , Idoso , Fatores de Risco , Capacidade Vital , Volume Expiratório Forçado , Pulmão/fisiopatologia , Estudos de Coortes
5.
BMC Pulm Med ; 24(1): 214, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38698432

RESUMO

BACKGROUND: In western Yokohama, our hospital and primary care clinics manage adults with asthma via a coordinated care system. We investigated the changes in the fractional expired nitric oxide (FeNO), forced expiratory volume in 1 second (FEV1), and forced oscillation technique (FOT) parameters over 3 years in a cohort of patients in our collaborative system. METHODS: From 288 adults with well controlled asthma managed under the Yokohama Seibu Hospital coordinated care system between January 2009 and May 2018, we selected 99 subjects to undergo spirometry, FeNO and FOT testing over 3 years and analyzed the changes in these parameters. RESULTS: Of the 99 patients enrolled, 17 (17.2%) experienced at least one exacerbation (insufficiently controlled (IC)), whereas, 82 (82.8%) remained in well controlled during the 3-year study period. Of well-controlled patients, 54 patients (54.5%) met the criteria for clinical remission under treatment (CR); the remaining 28 patients did not meet the CR criteria (WC). There were no differences in FeNO, FEV1, or FOT parameters at baseline among the IC, WC, and CR groups. The levels of FEV1 decreased gradually, whereas the levels of FeNO decreased significantly over 3 years. The levels of percent predicted FEV1 (%FEV1) significantly increased. We also observed significant improvement in FOT parameters; reactance at 5 Hz (R5), resonant frequency (Fres), and integral of reactance up to the resonant frequency (AX). The CR group demonstrated significant relationships between the change in FeNO and the change in FEV1 and between the change in FEV1 and the change in FOT parameters. No significant correlations emerged in the IC or WC group. CONCLUSION: The decrease in FeNO and increase in %FEV1, we observed in all study participants suggest that the coordinated care system model benefits patients with asthma. Although it is difficult to predict at baseline which patients will experience an exacerbation, monitoring changes in FeNO and FEV1 is useful in managing patients with asthma. Furthermore, monitoring changes in R5, Fres, and AX via forced oscillation technique testing is useful for detecting airflow limitation.


Assuntos
Asma , Espirometria , Humanos , Masculino , Feminino , Asma/fisiopatologia , Asma/terapia , Asma/diagnóstico , Volume Expiratório Forçado , Pessoa de Meia-Idade , Adulto , Óxido Nítrico/análise , Óxido Nítrico/metabolismo , Idoso , Teste da Fração de Óxido Nítrico Exalado
6.
PLoS One ; 19(5): e0302476, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38709742

RESUMO

BACKGROUND: The Incentive Spirometer (IS) increases lung volume and improves gas exchange by visually stimulating patients to take slow, deep breaths. It prevents respiratory complications and treats postoperative atelectasis in patients undergoing abdominal, thoracic, and neurosurgical procedures. Its effectiveness has been validated in studies that support improved lung capacities and volumes in individuals with respiratory complications, postoperative thoracic surgery, upper abdominal surgery, and bariatric surgery. The modified Pachón incentive spirometer (MPIS) is a cost-effective alternative to branded IS. It is crucial to validate whether the MPIS distributes ventilation as effectively as commercial devices do. Ventilation distribution will be measured using electrical impedance tomography. OBJECTIVE: The aim is to compare the distribution of pulmonary ventilation between the MPIS and another commercial IS in healthy adults using electrical impedance tomography. METHODS: A crossover clinical trial is proposed to evaluate the measurement of pulmonary ventilation distribution using EIT in a sample of healthy adults. All participants will use a commercial flow IS and the MPIS, with the order of assignment randomized. This research will use electrical impedance tomography to validate the operation of the MPIS. CONCLUSIONS: This study protocol will compare two incentive spirometers' impact on pulmonary ventilation, potentially endorsing the adoption of a cost-effective device to enhance accessibility for targeted populations. TRIAL REGISTRATION: The study was registered in ClinicalTrials.gov (NTC05532748).


Assuntos
Impedância Elétrica , Ventilação Pulmonar , Espirometria , Tomografia , Humanos , Adulto , Espirometria/métodos , Espirometria/instrumentação , Tomografia/métodos , Ventilação Pulmonar/fisiologia , Masculino , Feminino , Voluntários Saudáveis , Estudos Cross-Over , Pulmão/fisiologia , Pessoa de Meia-Idade , Adulto Jovem
7.
Respir Res ; 25(1): 194, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702779

RESUMO

Asthma is a common chronic disease amongst children. Epidemiological studies showed that the mortality rate of asthma in children is still high worldwide. Asthma control is therefore essential to minimize asthma exacerbations, which can be fatal if the condition is poorly controlled. Frequent monitoring could help to detect asthma progression and ensure treatment effectiveness. Although subjective asthma monitoring tools are available, the results vary as they rely on patients' self-perception. Emerging evidence suggests several objective tools could have the potential for monitoring purposes. However, there is no consensus to standardise the use of objective monitoring tools. In this review, we start with the prevalence and severity of childhood asthma worldwide. Then, we detail the latest available objective monitoring tools, focusing on their effectiveness in paediatric asthma management. Publications of spirometry, fractional exhaled nitric oxide (FeNO), hyperresponsiveness tests and electronic monitoring devices (EMDs) between 2016 and 2023 were included. The potential advantages and limitations of each tool were also discussed. Overall, this review provides a summary for researchers dedicated to further improving objective paediatric asthma monitoring and provides insights for clinicians to incorporate different objective monitoring tools in clinical practices.


Assuntos
Asma , Humanos , Asma/diagnóstico , Asma/terapia , Asma/fisiopatologia , Asma/epidemiologia , Criança , Espirometria/métodos , Monitorização Fisiológica/métodos , Gerenciamento Clínico , Teste da Fração de Óxido Nítrico Exalado/métodos
8.
Int J Chron Obstruct Pulmon Dis ; 19: 1011-1019, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38737192

RESUMO

Purpose: The prevalence of airflow obstruction in Japan is 3.8%-16.9%. This epidemiological study based on a large database aimed to reassess the prevalence of airflow obstruction in Japan and the diagnosis rate of chronic obstructive pulmonary disease (COPD). Patients and Methods: We used data regarding claims from the health insurance union and health checkups provided by JMDC. The present study included a subgroup of individuals aged ≥40 years who underwent health checkups involving spirometry between January and December 2019. The study endpoints were the prevalence of airflow obstruction, COPD diagnosis rate, disease stage, and respiratory function test results. Results: Among 102,190 participants, 4113 (4.0%) had airflow obstruction. The prevalence of airflow obstruction was 5.3% in men and 2.1% in women. Among the study population, 6.8% were current smokers, while 3.4% were never or former smokers. Additionally, the prevalence of COPD increased with age. Approximately 8.4% of participants with airflow obstruction were diagnosed with COPD. Regarding the COPD diagnosis status, participants with airflow obstruction who were diagnosed with COPD were at a more advanced stage than those not diagnosed. Finally, patients diagnosed with COPD had significantly lower FEV1/FVC and FEV1 (p < 0.0001; Wilcoxon rank sum test). Conclusion: The epidemiological study based on a large database determined the COPD diagnosis rate related to airflow obstruction. The COPD diagnosis rate was extremely low among individuals who underwent health checkups, indicating the need for increased awareness about this medical condition. Moreover, primary care physicians should identify patients with suspected COPD and collaborate with pulmonologists to facilitate the early detection of COPD and enhance the COPD diagnosis rate.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Espirometria , Humanos , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Masculino , Feminino , Japão/epidemiologia , Pessoa de Meia-Idade , Prevalência , Idoso , Adulto , Volume Expiratório Forçado , Bases de Dados Factuais , Pulmão/fisiopatologia , Capacidade Vital , Fumar/epidemiologia , Fumar/efeitos adversos , Valor Preditivo dos Testes , Índice de Gravidade de Doença
9.
J Assoc Physicians India ; 72(3): 55-62, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38736118

RESUMO

The Global Lung Initiative (GLI) race-neutral equations are considered to be race agnostic, using inverse probability weight, and have lower limits of normality (LLN) different from the GLI mixed equations. In this observational study, we analyzed the impact of using GLI equations to interpret spirometry of 1,169 patients with chronic respiratory diseases, including asthma, chronic obstructive pulmonary disease (COPD), COPD suspects, small airway obstruction, posttubercular lung disease, and preserved ratio with impaired spirometry (PRISm) (46% females, average age 46 years). Predicted normal and the LLN using GLI equations were significantly higher than those using Indian equations. The GLI race-neutral equations changed the category in 35.17% of males and 42.64% of females compared to Indian equations. The GLI mixed equations categorized a greater percentage of patients to have a mixed ventilatory pattern compared to the GLI race-neutral equations. There was a significant change in the grading of the severity of COPD using Global Initiative for Chronic Obstructive Lung Disease (GOLD) stages based on the percentage of predicted values of FEV1. Although GLI race-neutral equations have greater concordance with Indian equations than GLI Mixed equations, these substantially overdiagnose abnormal ventilatory patterns on spirometry in adult Indians in western India with chronic respiratory disease. A substantial number of patients with normal or obstructive patterns on spirometry are recategorized to have mixed or restrictive patterns. The use of GLI race-neutral equations increases the severity of airflow limitation in COPD patients. GLI race-neutral predictions for FEV1 result in substantially fewer patients demonstrating postbronchodilator responsiveness (PBDR).


Assuntos
Doença Pulmonar Obstrutiva Crônica , Espirometria , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Índia , Espirometria/métodos , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/etnologia , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Adulto , Volume Expiratório Forçado , Asma/fisiopatologia , Asma/diagnóstico , Asma/etnologia , Doença Crônica , Índice de Gravidade de Doença
10.
Med Sci (Basel) ; 12(2)2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38651412

RESUMO

Chronic Obstructive Pulmonary Disease (COPD) is a disease of the lungs characterized by chronic airflow obstruction. Individuals with preserved ratio impaired spirometry (PRISm) may be at risk for developing COPD. This study aimed to characterize PRISm and COPD patients in terms of their immune response and endocrine profile to identify differences extending beyond lung function. The participants performed the clinical assessment, pulmonary function test, and blood collection to determine serum hormone levels and concentrations of cytokine. Differences were observed in the nutritional status, lung function, and comorbidity. There were no differences in IL-6, IL-8, IL-10, IL-12, and TNF levels between PRISm and COPD groups. Both PRISm and COPD patients have lower dehydroepiandrosterone (DHEA) and dehydroepiandrosterone sulfate (DHEA-S) levels than controls. Correlation analysis of PRISm and COPD patients revealed positive correlations between serum levels of DHEA-S and DHEA, with forced expiratory volume in 1 second (FEV1) and forced vital capacity (FVC), which negatively correlated with IL-8 levels. The results indicated that despite differences in lung function parameters, the PRISm and COPD groups exhibited similarities in endocrine profile alterations. This study represents the first attempt to link endocrine with immune markers and lung function in individuals with PRISm.


Assuntos
Biomarcadores , Doença Pulmonar Obstrutiva Crônica , Espirometria , Humanos , Doença Pulmonar Obstrutiva Crônica/sangue , Masculino , Feminino , Biomarcadores/sangue , Pessoa de Meia-Idade , Idoso , Citocinas/sangue , Desidroepiandrosterona/sangue , Inflamação/sangue , Sulfato de Desidroepiandrosterona/sangue , Capacidade Vital , Testes de Função Respiratória , Volume Expiratório Forçado
11.
BMC Pulm Med ; 24(1): 183, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38632576

RESUMO

BACKGROUND: Despite being a prognostic predictor, cardiac autonomic dysfunction (AD) has not been well investigated in chronic obstructive pulmonary disease (COPD). We aimed to characterise computed tomography (CT), spirometry, and cardiopulmonary exercise test (CPET) features of COPD patients with cardiac AD and the association of AD with CT-derived vascular and CPET-derived ventilatory efficiency metrics. METHODS: This observational cohort study included stable, non-severe COPD patients. They underwent clinical evaluation, spirometry, CPET, and CT. Cardiac AD was determined based on abnormal heart rate responses to exercise, including chronotropic incompetence (CI) or delayed heart rate recovery (HRR) during CPET. RESULTS: We included 49 patients with FEV1 of 1.2-5.0 L (51.1-129.7%), 24 (49%) had CI, and 15 (31%) had delayed HRR. According to multivariate analyses, CI was independently related to reduced vascular volume (VV; VV ≤ median; OR [95% CI], 7.26 [1.56-33.91]) and low ventilatory efficiency (nadir VE/VCO2 ≥ median; OR [95% CI], 10.67 [2.23-51.05]). Similar results were observed for delayed HRR (VV ≤ median; OR [95% CI], 11.46 [2.03-64.89], nadir VE/VCO2 ≥ median; OR [95% CI], 6.36 [1.18-34.42]). CONCLUSIONS: Cardiac AD is associated with impaired pulmonary vascular volume and ventilatory efficiency. This suggests that lung blood perfusion abnormalities may occur in these patients. Further confirmation is required in a large population-based cohort.


Assuntos
Pneumopatias , Doença Pulmonar Obstrutiva Crônica , Humanos , Frequência Cardíaca/fisiologia , Pneumopatias/complicações , Teste de Esforço/métodos , Espirometria , Tolerância ao Exercício/fisiologia
12.
Pulm Med ; 2024: 3446536, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38650913

RESUMO

Background: The denomination of noncystic fibrosis bronchiectasis (NCFB) includes several causes, and differences may be expected between the patient subgroups regarding age, comorbidities, and clinical and functional evolution. This study sought to identify the main causes of NCFB in a cohort of stable adult patients and to investigate whether such conditions would be different in their clinical, functional, and quality of life aspects. Methods: Between 2017 and 2019, all active patients with NCFB were prospectively evaluated searching for clinical data, past medical history, dyspnea severity grading, quality of life data, microbiological profile, and lung function (spirometry and six-minute walk test). Results: There was a female predominance; mean age was 54.7 years. Causes were identified in 82% of the patients, the most frequent being postinfections (n = 39), ciliary dyskinesia (CD) (n = 32), and chronic obstructive pulmonary disease (COPD) (n = 29). COPD patients were older, more often smokers (or former smokers) and with more comorbidities; they also had worse lung function (spirometry and oxygenation) and showed worse performance in the six-minute walk test (6MWT) (walked distance and exercise-induced hypoxemia). Considering the degree of dyspnea, in the more symptomatic group, patients had higher scores in the three domains and total score in SGRQ, besides having more exacerbations and more patients in home oxygen therapy. Conclusions: Causes most identified were postinfections, CD, and COPD. Patients with COPD are older and have worse pulmonary function and more comorbidities. The most symptomatic patients are clinically and functionally more severe, besides having worse quality of life.


Assuntos
Bronquiectasia , Doença Pulmonar Obstrutiva Crônica , Qualidade de Vida , Teste de Caminhada , Humanos , Feminino , Bronquiectasia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Idoso , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/complicações , Adulto , Dispneia/fisiopatologia , Transtornos da Motilidade Ciliar/fisiopatologia , Transtornos da Motilidade Ciliar/complicações , Estudos Prospectivos , Espirometria , Comorbidade
13.
COPD ; 21(1): 2321379, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38655897

RESUMO

INTRODUCTION: Spirometry is the gold standard for COPD diagnosis and severity determination, but is technique-dependent, nonspecific, and requires administration by a trained healthcare professional. There is a need for a fast, reliable, and precise alternative diagnostic test. This study's aim was to use interpretable machine learning to diagnose COPD and assess severity using 75-second carbon dioxide (CO2) breath records captured with TidalSense's N-TidalTM capnometer. METHOD: For COPD diagnosis, machine learning algorithms were trained and evaluated on 294 COPD (including GOLD stages 1-4) and 705 non-COPD participants. A logistic regression model was also trained to distinguish GOLD 1 from GOLD 4 COPD with the output probability used as an index of severity. RESULTS: The best diagnostic model achieved an AUROC of 0.890, sensitivity of 0.771, specificity of 0.850 and positive predictive value (PPV) of 0.834. Evaluating performance on all test capnograms that were confidently ruled in or out yielded PPV of 0.930 and NPV of 0.890. The severity determination model yielded an AUROC of 0.980, sensitivity of 0.958, specificity of 0.961 and PPV of 0.958 in distinguishing GOLD 1 from GOLD 4. Output probabilities from the severity determination model produced a correlation of 0.71 with percentage predicted FEV1. CONCLUSION: The N-TidalTM device could be used alongside interpretable machine learning as an accurate, point-of-care diagnostic test for COPD, particularly in primary care as a rapid rule-in or rule-out test. N-TidalTM also could be effective in monitoring disease progression, providing a possible alternative to spirometry for disease monitoring.


Assuntos
Capnografia , Aprendizado de Máquina , Doença Pulmonar Obstrutiva Crônica , Índice de Gravidade de Doença , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Humanos , Pessoa de Meia-Idade , Masculino , Feminino , Capnografia/métodos , Idoso , Modelos Logísticos , Sensibilidade e Especificidade , Volume Expiratório Forçado , Algoritmos , Valor Preditivo dos Testes , Área Sob a Curva , Estudos de Casos e Controles , Espirometria/instrumentação
14.
Respir Res ; 25(1): 162, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622608

RESUMO

BACKGROUND: Remote monitoring of patient-recorded spirometry and pulse oximetry offers an alternative approach to traditional hospital-based monitoring of interstitial lung disease (ILD). Remote spirometry has been observed to reasonably reflect clinic spirometry in participants with ILD but remote monitoring has not been widely incorporated into clinical practice. We assessed the feasibility of remotely monitoring patients within a clinical ILD service. METHODS: Prospective, single-arm, open-label observational multi-centre study (NCT04850521). Inclusion criteria included ILD diagnosis, age ≥ 18 years, FVC ≥ 50% predicted. 60 participants were asked to record a single spirometry and oximetry measurement at least once daily, monitored weekly by their local clinical team. Feasibility was defined as ≥ 68% of participants with ≥ 70% adherence to study measurements and recording measurements ≥ 3 times/week throughout. RESULTS: A total of 60 participants were included in the analysis. 42/60 (70%) were male; mean age 67.8 years (± 11.2); 34/60 (56.7%) had idiopathic pulmonary fibrosis (IPF), Median ILD-GAP score was 3 (IQR 1-4.75). Spirometry adherence was achieved for ≥ 70% of study days in 46/60 participants (77%) and pulse oximetry adherence in 50/60 participants (83%). Recording ≥ 3 times/week every week was provided for spirometry in 41/60 participants (68%) and pulse oximetry in 43/60 participants (72%). Mean difference between recent clinic and baseline home spirometry was 0.31 L (± 0.72). 85.7% (IQR 63.9-92.6%) home spirometry attempts/patient were acceptable or usable according to ERS/ATS spirometry criteria. Positive correlation was observed between ILD-GAP score and adherence to spirometry and oximetry (rho 0.24 and 0.38 respectively). Adherence of weekly monitoring by clinical teams was 80.95% (IQR 64.19-95.79). All participants who responded to an experience questionnaire (n = 33) found remote measurements easy to perform and 75% wished to continue monitoring their spirometry at the conclusion of the study. CONCLUSION: Feasibility of remote monitoring within an ILD clinical service was demonstrated over 3 months for both daily home spirometry and pulse oximetry of patients. Remote monitoring may be more acceptable to participants who are older or have more advanced disease. TRIAL REGISTRATION: clinicaltrials.gov NCT04850521 registered 20th April 2021.


Assuntos
Doenças Pulmonares Intersticiais , Humanos , Masculino , Idoso , Adolescente , Feminino , Estudos Prospectivos , Estudos de Viabilidade , Capacidade Vital , Doenças Pulmonares Intersticiais/diagnóstico , Espirometria , Oximetria
15.
J Cardiothorac Surg ; 19(1): 223, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627776

RESUMO

OBJECTIVE: The aim of this study is to investigate the clinical value and potential prognostic significance of lung function assessment and Testin expression in non-small cell lung cancer (NSCLC) patients. METHODS: The NSCLC patients were classified into three groups according to lung function: group of normal lung function, group of PRISm (preserved ratio impaired spirometry) (FEV1, forced expiratory volume during the first second < 80% predicted and FEV1/FVC (forced vital capacity) ≥ 70%) and group of COPD (chronic obstructive pulmonary disease) (FEV1/FVC < 70%). The pre-operational clinicopathological characteristics of these patients were recorded and the markers of systemic inflammatory response, including neutrophil to lymphocyte ratio (NLR), lymphocyte to monocyte ratio (LMR), platelet to lymphocyte ratio (PLR) and eosinophils (EOS), were compared between three groups. The expression of Testin in NSCLC samples was detected by IHC and we further explored the correlation between Testin expression and clinicopathological characteristics and prognosis of NSCLC patients. Finally, Cox regression analysis was conducted to study the prognostic factors of NSCLC patients. RESULTS: Of the 158 NSCLC patients, percentages of normal lung function, PRISm and COPD were 41.4%, 22.8% and 36.1%, respectively. Patients with tumor in the left lung were more likely to have pulmonary dysfunction (PRISm and COPD) than the right lung. The markers of systemic inflammatory response showed differences to various degree in the three groups and NSCLC patients with PRISm or COPD presented more unfavorable prognosis than patients with normal function. The expression of Testin correlated with lymph node metastasis, TNM stage and tumor invasion of NSCLC patients. Moreover, patients with low Testin expression exhibited poorer disease-free survival and overall survival than those with high Testin expression. In Cox regression analysis, we found that PRISm, COPD and Testin expression served as prognostic factors in NSCLC patients. CONCLUSIONS: The presence of COPD or PRISm influenced systemic inflammatory response and prognosis of NSCLC patients. Testin expression correlated with clinicopathological features and could be potentially used as a prognostic marker in NSCLC.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Doença Pulmonar Obstrutiva Crônica , Humanos , Carcinoma Pulmonar de Células não Pequenas/patologia , Volume Expiratório Forçado , Pulmão/patologia , Neoplasias Pulmonares/patologia , Prognóstico , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Espirometria , Síndrome de Resposta Inflamatória Sistêmica
16.
Braz J Cardiovasc Surg ; 39(3): e20220319, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38629953

RESUMO

INTRODUCTION: Cardiac surgery is a frequent surgical procedure and may present a high risk of complications. Among the prophylactic strategies studied to decrease the rates of negative outcomes, respiratory care seems to reduce pulmonary complications. Incentive spirometry (IS) is a low-cost, respiratory exercise technique, used for the prevention and treatment of postoperative pulmonary complications (PPC). The aim of this review was to evaluate whether IS is superior to respiratory care, mobilization exercises, and noninvasive ventilation on PPC, and clinical outcomes. METHODS: Systematic review. Medical Literature Analysis and Retrieval System Online (or MEDLINE®), Embase®, Cochrane Central Register of Controlled Trials (or CENTRAL), Physiotherapy Evidence Database (or PEDro), Cumulative Index of Nursing and Allied Health (or CINAHL®), Latin American and Caribbean Health Sciences Literature (or LILACS), Scientific Electronic Library Online (or SciELO), Allied, Scopus®, and OpenGrey databases, clinical trial registration sites, conferences, congresses, and symposiums were searched. RESULTS: Twenty-one randomized trials and one quasi-randomized trial (1,677 participants) were included. For partial pressure of oxygen (PaO2), IS was inferior to respiratory care (mean difference [MD] -4.48; 95% confidence interval [CI] -8.32 to -0.63). Flow-oriented IS was inferior to respiratory care on PaO2 (MD -4.53; 95% CI -8.88 to -0.18). However, compared to respiratory care, flow-oriented IS was superior on recovery vital capacity. CONCLUSIONS: This meta-analysis revealed that IS was not superior to standard respiratory care for PPCs and clinical outcomes, therefore its use should not be widely recommended until further studies with high quality be performed to ensure this clinical guidance.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Espirometria , Humanos , Hospitais , Unidades de Terapia Intensiva , Motivação , Oxigênio , Modalidades de Fisioterapia
17.
BMJ Paediatr Open ; 8(1)2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38599800

RESUMO

OBJECTIVE: To determine whether weekly oral vitamin D supplementation influences growth, body composition, pubertal development or spirometric outcomes in South African schoolchildren. DESIGN: Phase 3 double-blind randomised placebo-controlled trial. SETTING: Socioeconomically disadvantaged peri-urban district of Cape Town, South Africa. PARTICIPANTS: 1682 children of black African ancestry attending government primary schools and aged 6-11 years at baseline. INTERVENTIONS: Oral vitamin D3 (10 000 IU/week) versus placebo for 3 years. MAIN OUTCOME MEASURES: Height-for-age and body mass index-for-age, measured in all participants; Tanner scores for pubertal development, spirometric lung volumes and body composition, measured in a subset of 450 children who additionally took part in a nested substudy. RESULTS: Mean serum 25-hydroxyvitamin D3 concentration at 3-year follow-up was higher among children randomised to receive vitamin D versus placebo (104.3 vs 64.7 nmol/L, respectively; mean difference (MD) 39.7 nmol/L, 95% CI 37.6 to 41.9 nmol/L). No statistically significant differences in height-for-age z-score (adjusted MD (aMD) -0.08, 95% CI -0.19 to 0.03) or body mass index-for-age z-score (aMD -0.04, 95% CI -0.16 to 0.07) were seen between vitamin D versus placebo groups at follow-up. Among substudy participants, allocation to vitamin D versus placebo did not influence pubertal development scores, % predicted forced expiratory volume in 1 s (FEV1), % predicted forced vital capacity (FVC), % predicted FEV1/FVC, fat mass or fat-free mass. CONCLUSIONS: Weekly oral administration of 10 000 IU vitamin D3 boosted vitamin D status but did not influence growth, body composition, pubertal development or spirometric outcomes in South African schoolchildren. TRIAL REGISTRATION NUMBERS: ClinicalTrials.gov NCT02880982, South African National Clinical Trials Register DOH-27-0916-5527.


Assuntos
Colestanos , Deficiência de Vitamina D , Criança , Humanos , Composição Corporal , Colecalciferol/uso terapêutico , Colestanos/uso terapêutico , Suplementos Nutricionais , África do Sul/epidemiologia , Espirometria , Vitamina D/uso terapêutico , Deficiência de Vitamina D/tratamento farmacológico , Vitaminas/uso terapêutico , Método Duplo-Cego
18.
Wiad Lek ; 77(2): 208-213, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38592980

RESUMO

OBJECTIVE: Aim: To determine the dynamics of renewal of the function of external respiration in patients after laparoscopic cholecystectomy at the acute stage of rehabilitation under the influence of a rehabilitation program. PATIENTS AND METHODS: Materials and Methods: The study is randomized, simple with blinded assessors. The forced vital capacity (FVC, l), forced expiratory volume in the first second (FEV1, l) and peak expiratory flow rate (PEFR, l/s) were assessed. Spirometry was performed 120 patients on the first day of admission of patients to the surgical department for surgical intervention, on the second day and on the day of discharge. Methods of mathematical statistics: arithmetic mean (M) and standard error of the mean (}m), Student's t-test were calculated, differences at p<0,05 were considered statistically significant. RESULTS: Results: It has been established that laparoscopic cholecystectomy leads to a statistically significant decrease in the parameters of respiratory function in all age categories. More pronounced positive dynamics of respiratory function in the group of respiratory therapy. It was established that without respiratory therapy on the day of discharge there was no restoration (р<0.05) in groups of elderly patients of group of FVC l, FEV1 l, PEFR l/s; in middle-aged patients did no restoration FEV1, l, PEFR, l/s; in younger patients there was no recovery of FEV1, l. CONCLUSION: Conclusions: The results of the study indicate the effectiveness of the introduction of diaphragmatic breathing exercises in combination with early mobilization at the acute and subacute stages of rehabilitation in patients after laparoscopic cholecystectomy in order to restore the function of the respiratory system.


Assuntos
Colecistectomia Laparoscópica , Idoso , Humanos , Pessoa de Meia-Idade , Colecistectomia Laparoscópica/métodos , Volume Expiratório Forçado , Respiração , Testes de Função Respiratória , Espirometria
19.
Respir Res ; 25(1): 155, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38570835

RESUMO

BACKGROUND: Reference values for lung volumes are necessary to identify and diagnose restrictive lung diseases and hyperinflation, but the values have to be validated in the relevant population. Our aim was to investigate the Global Lung Function Initiative (GLI) reference equations in a representative healthy Austrian population and create population-derived reference equations if poor fit was observed. METHODS: We analysed spirometry and body plethysmography data from 5371 respiratory healthy subjects (6-80 years) from the Austrian LEAD Study. Fit with the GLI equations was examined using z-scores and distributions within the limits of normality. LEAD reference equations were then created using the LMS method and the generalized additive model of location shape and scale package according to GLI models. RESULTS: Good fit, defined as mean z-scores between + 0.5 and -0.5,was not observed for the GLI static lung volume equations, with mean z-scores > 0.5 for residual volume (RV), RV/TLC (total lung capacity) and TLC in both sexes, and for expiratory reserve volume (ERV) and inspiratory capacity in females. Distribution within the limits of normality were shifted to the upper limit except for ERV. Population-derived reference equations from the LEAD cohort showed superior fit for lung volumes and provided reproducible results. CONCLUSION: GLI lung volume reference equations demonstrated a poor fit for our cohort, especially in females. Therefore a new set of Austrian reference equations for static lung volumes was developed, that can be applied to both children and adults (6-80 years of age).


Assuntos
Pulmão , Masculino , Adulto , Criança , Feminino , Humanos , Áustria/epidemiologia , Valores de Referência , Medidas de Volume Pulmonar/métodos , Capacidade Pulmonar Total , Espirometria/métodos , Volume Expiratório Forçado , Capacidade Vital
20.
Adv Respir Med ; 92(2): 158-174, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38666812

RESUMO

COPD is the third leading cause of death worldwide. Its diagnosis can be made with spirometry, which is underused due to its limited accessibility. Portable spirometry holds promise for enhancing the efficacy of COPD diagnoses. The study aimed to estimate COPD prevalence diagnosed with a portable spirometer in high-risk patients and compare it with COPD prevalence based on data from conventional, on-site spirometry. We also evaluated the strategy of a proactive approach to identify COPD in high-risk individuals. We conducted a systematic review of original studies on COPD targeted screening and diagnosis with portable and conventional spirometers selected from 8496 publications initially found in three databases: Cochrane, PubMed, and Embase. The inclusion criteria were met by 28 studies. COPD prevalence evaluated with the use of portable spirometers reached 20.27% and was lower compared to that estimated with the use of conventional spirometers (24.67%). In 11 included studies, postbronchodilator tests were performed with portable spirometers, which enabled a bedside COPD diagnosis. Portable spirometers can be successfully used in COPD targeted screening and diagnosis and thus enhance the detection of COPD at early stages.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Espirometria , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Humanos , Espirometria/métodos , Espirometria/instrumentação , Programas de Rastreamento/métodos , Diagnóstico Precoce
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...