Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.665
Filtrar
1.
J Acoust Soc Am ; 156(2): 954-967, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39133632

RESUMO

Over the past few decades, early osteoporosis detection using ultrasonic bone quality evaluation has gained prominence. Specifically, various studies focused on axial transmission using ultrasonic guided waves and have highlighted this technique's sensitivity to intrinsic properties of long cortical bones. This work aims to demonstrate the potential of low-frequency ultrasonic guided waves to infer the properties of the bone inside which they are propagating. A proprietary ultrasonic transducer, tailored to transmit ultrasonic guided waves under 500 kHz, was used for the data collection. The gathered data underwent two-dimensional fast Fourier transform processing to extract experimental dispersion curves. The proposed inversion scheme compares experimental dispersion curves with simulated dispersion curves calculated through the semi-analytical iso-geometric analysis (SAIGA) method. The numerical model integrates a bone phantom plate coupled with a soft tissue layer on its top surface, mimicking the experimental bone phantom plates. Subsequently, the mechanical properties of the bone phantom plates were estimated by reducing the misfit between the experimental and simulated dispersion curves. This inversion leaned heavily on the dispersive trajectories and amplitudes of ultrasonic guided wave modes. Results indicate a marginal discrepancy under 5% between the mechanical properties ascertained using the SAIGA-based inversion and those measured using bulk wave pulse-echo measurements.


Assuntos
Osso Cortical , Imagens de Fantasmas , Ultrassonografia , Osso Cortical/diagnóstico por imagem , Osso Cortical/fisiologia , Ultrassonografia/métodos , Ultrassonografia/instrumentação , Análise de Fourier , Ondas Ultrassônicas , Humanos , Transdutores , Análise Numérica Assistida por Computador , Simulação por Computador
2.
BMC Oral Health ; 24(1): 924, 2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39123162

RESUMO

BACKGROUND: The infrazygomatic crest mini-screw has been widely used, but the biomechanical performance of mini-screws at different insertion angles is still uncertain. The aim of this study was to analyse the primary stability of infrazygomatic crest mini-screws at different angles and to explore the effects of the exposure length (EL), screw-cortical bone contact area (SCA), and screw-trabecular bone contact area (STA) on this primary stability. METHODS: Ninety synthetic bones were assigned to nine groups to insert mini-screws at the cross-combined angles in the occlusogingival and mesiodistal directions. SCA, STA, EL, and lateral pull-out strength (LPS) were measured, and their relationships were analysed. Twelve mini-screws were then inserted at the optimal and poor angulations into the maxillae from six fresh cadaver heads, and the same biomechanical metrics were measured for validation. RESULTS: In the synthetic-bone test, the LPS, SCA, STA, and EL had significant correlations with the angle in the occlusogingival direction (rLPS = 0.886, rSCA = -0.946, rSTA = 0.911, and rEL= -0.731; all P < 0.001). In the cadaver-validation test, significant differences were noted in the LPS (P = 0.011), SCA (P = 0.020), STA (P = 0.004), and EL (P = 0.001) between the poor and optimal angulations in the occlusogingival direction. The STA had positive correlations with LPS (rs = 0.245 [synthetic-bone test] and r = 0.720 [cadaver-validation test]; both P < 0.05). CONCLUSIONS: The primary stability of the infrazygomatic crest mini-screw was correlated with occlusogingival angulations. The STA significantly affected the primary stability of the infrazygomatic crest mini-screw, but the SCA and EL did not.


Assuntos
Parafusos Ósseos , Osso Esponjoso , Osso Cortical , Humanos , Osso Cortical/anatomia & histologia , Fenômenos Biomecânicos , Osso Esponjoso/anatomia & histologia , Procedimentos de Ancoragem Ortodôntica/instrumentação , Procedimentos de Ancoragem Ortodôntica/métodos , Cadáver , Zigoma/cirurgia , Zigoma/anatomia & histologia , Maxila/anatomia & histologia , Análise do Estresse Dentário
3.
Shanghai Kou Qiang Yi Xue ; 33(2): 211-218, 2024 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-39005102

RESUMO

PURPOSE: To investigate the effects of different cortical bone thickness and jaw bone density at implant sites on intraoperative pain during implant surgery. METHODS: One hundred and eighty-seven patients(263 implant sites) who underwent implant placement surgery at the Fourth Affiliated Hospital of Nanchang University from August 2021 to August 2022 were selected to investigate the effects of different cortical bone thickness and jaw bone density HU values at implant sites on the anesthetic effect under local infiltration anesthesia with epinephrine in articaine. SPSS 26.0 software package was used for data analysis. RESULTS: The mean cortical bone thickness at the painful sites[(3.90±1.36) mm] was significantly greater than that at the non-painful sites [(2.24±0.66) mm], and the difference was statistically significant(P<0.05). The differences in cortical bone thickness in the mandibular anterior, premolar, and molar regions were statistically significant in the comparison of pain and non-pain sites. The mean HU value of bone density was (764.46±239.75) for the painful sites and (612.23±235.31) for the non-painful sites, with significant difference(P<0.05). The difference was not significant(P>0.05) when comparing the HU values of painful sites with non-painful sites in the mandibular anterior teeth and anterior molar region, while the difference was significant(P<0.05) when comparing the HU values of painful sites with non-painful sites in the mandibular molar region. CONCLUSIONS: Sites with large cortical bone thickness have a greater effect on blocking infiltrative anesthetic penetration and are more prone to intraoperative pain during implantation. In the mandibular anterior and premolar regions, the HU value of the implant sites had less effect on infiltrative anesthetic penetration, and the effect was greater in the mandibular molar region, and the implant sites with high HU values in the mandibular molar region were more likely to have intraoperative pain. When the cortical bone thickness in the planned implant site is greater than 3.9 mm and the mean bone density in the mandibular molar region is greater than 665 HU. If there is sufficient safe distance for hole operation, it is recommended to apply mandibular nerve block anesthesia combined with articaine infiltration anesthesia to avoid intraoperative pain and bad surgical experience for the patients.


Assuntos
Densidade Óssea , Osso Cortical , Mandíbula , Humanos , Densidade Óssea/efeitos dos fármacos , Mandíbula/cirurgia , Mandíbula/anatomia & histologia , Osso Cortical/anatomia & histologia , Implantes Dentários , Anestesia Local/métodos , Dor/etiologia , Carticaína/administração & dosagem
4.
Biomed Phys Eng Express ; 10(5)2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-38986445

RESUMO

Miniscrews are widely used in orthodontics as an anchorage device while aligning teeth. Shear stress in the miniscrew-bone interface is an important factor when the miniscrew makes contact with the bone. The objective of this study was to analyze the shear stress and force in the screw-bone interface for varying Cortical Bone Thickness (CBT) using Finite Element Analysis (FEA). Varying CBT of 1.09 mm (1.09CBT) and 2.66 mm (2.66CBT) with miniscrews of Ø1.2 mm, 10 mm length (T1), Ø1.2 mm, 6 mm length (T2) and Ø1.6 mm, 8 mm length (T3) were analyzed. Six Finite Element (FE) models were developed with cortical, cancellous bone, miniscrews and gingiva as a prism. A deflection of 0.1 mm was applied on the neck of the miniscrews at 0°, +30° and -30° angles. The shear stress and force in the screw-bone interface were assessed. The results showed that the CBT affects the shear stress and force in the screw-bone interface region in addition to the screw dimensions and deflection angulations. T1 screw generated lesser shear stress in 1.09CBTand 2.66CBTcompared to T2 and T3 screws. Higher CBT is preferred for better primary stability in shear aspect. Clinically applied forces of 200 gms to 300 gms to an anchorage device induces shear stress in the miniscrew-bone interface region might cause stress shielding. Thus, clinicians need to consider the effect of varying CBT and the size of the miniscrews for the stability, reduced stress shielding and better anchorage during orthodontic treatment.


Assuntos
Parafusos Ósseos , Osso Cortical , Análise de Elementos Finitos , Procedimentos de Ancoragem Ortodôntica , Resistência ao Cisalhamento , Estresse Mecânico , Humanos , Procedimentos de Ancoragem Ortodôntica/instrumentação , Procedimentos de Ancoragem Ortodôntica/métodos , Fenômenos Biomecânicos , Gengiva , Simulação por Computador , Osso Esponjoso
5.
J Orthop Surg Res ; 19(1): 355, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38879553

RESUMO

BACKGROUND: The purpose of this study was to clarify (1) the differences in cortical bone thickness (CBT) of the tibial diaphysis between healthy and osteoarthritic knees and (2) the influences of the femorotibial angle (FTA) and inclination of the medial compartment of the proximal tibia (MCT) on tibial CBT. METHODS: The study assessed 60 subjects with varus knee osteoarthritis (OA) (22 males and 38 females; mean age, 74 ± 7 years) and 53 healthy elderly subjects (28 males and 25 females; mean age, 70 ± 6 years). Three-dimensional estimated CBT of the tibial diaphysis was automatically calculated for 2752-11,296 points using high-resolution measurements from CT. The standardized CBT was assessed in 24 regions by combining six heights and four areas. Additionally, the association between the CBT, each FTA, and MCT inclination was investigated. RESULTS: The OA group showed a thicker CBT in the medial areas than in the lateral areas of the proximal tibia, while the healthy group had a thicker lateral CBT. The medial-to-lateral ratio of the proximal tibia was significantly higher in the OA group than in the healthy group. The proximal-medial CBT correlated with FTA and MCT inclinations in the OA group. CONCLUSIONS: This study demonstrated that varus osteoarthritic knees showed a different trend of proximal-medial CBT with associations in FTA and MCT inclination from healthy knees, possibly due to medial load concentration.


Assuntos
Osso Cortical , Diáfises , Osteoartrite do Joelho , Tíbia , Humanos , Masculino , Feminino , Tíbia/diagnóstico por imagem , Tíbia/patologia , Idoso , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/patologia , Osso Cortical/diagnóstico por imagem , Osso Cortical/patologia , Diáfises/diagnóstico por imagem , Diáfises/patologia , Idoso de 80 Anos ou mais , Tomografia Computadorizada por Raios X , Extremidade Inferior/diagnóstico por imagem , Pessoa de Meia-Idade
6.
J Oral Implantol ; 50(3): 220-230, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38839068

RESUMO

This study analyzed the stress distributions on zygomatic and dental implants placed in the zygomatic bone, supporting bones, and superstructures under occlusal loads after maxillary reconstruction with obturator prostheses. A total of 12 scenarios of 3-dimensional finite element models were constructed based on computerized tomography scans of a hemimaxillectomy patient. Two obturator prostheses were analyzed for each model. A total force of 600 N was applied from the palatal to buccal bones at an angle of 45°. The maximum and minimum principal stress values for bone and von Mises stress values for dental implants and prostheses were calculated. When zygomatic implants were applied to the defect area, the maximum principal stresses were similar in intensity to the other models; however, the minimum principal stress values were higher than in scenarios without zygomatic implants. In models that used zygomatic implants in the defect area, von Mises stress levels were significantly higher in zygomatic implants than in dental implants. In scenarios where the prosthesis was supported by tissue in the nondefect area, the maximum and minimum principal stress values on cortical bone were higher than in scenarios where implants were applied to defect and nondefect areas. In patients who lack an alveolar crest after maxillectomy, a custom bar-retained prosthesis placed on the dental implant should reduce stress on the zygomatic bone. The stress was higher on zygomatic implants without alveolar crest support than on dental implants.


Assuntos
Implantes Dentários , Análise de Elementos Finitos , Maxila , Obturadores Palatinos , Zigoma , Humanos , Zigoma/cirurgia , Maxila/cirurgia , Imageamento Tridimensional , Análise do Estresse Dentário , Força de Mordida , Fenômenos Biomecânicos , Simulação por Computador , Estresse Mecânico , Osso Cortical , Tomografia Computadorizada por Raios X , Implantação Dentária Endóssea/métodos , Prótese Dentária Fixada por Implante
7.
J Mech Behav Biomed Mater ; 157: 106632, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38917557

RESUMO

Understanding the behaviour and material properties of bone is critical in predicting the failure and fracture of bones in humans. To address this, mechanical tests have traditionally been conducted to characterize bone material and this has resulted in large body of literature. However, there appears to be a lack of complete information regarding the storage protocols used for bone specimens prior to conducting mechanical tests. For example, while storage methods are well described, parameters such as the time between donor death and bone retrieval, as well as time between specimen machining and testing, are seldom reported. As biological materials undergo degradation in storage after being removed from the donor, a clear understanding of this degradation behaviour would identify critical time frames in which previously stored cortical bone specimens should be tested such that they can still be considered representative of an in-vivo condition. In this paper, the results of an investigation to determine the effects of long duration storage on the measured mechanical properties of bovine cortical bone are reported. Three different storage protocols are compared; namely machined-refrigerated, machined-frozen and frozen-machined-frozen. Degradation effects are evident for both refrigerated and frozen specimens and the results demonstrate that testing bone specimens after more than one week in storage may not provide representative in-vivo properties. In addition, specimens exhibit severe degradation after six months in storage regardless of the storage protocol.


Assuntos
Osso Cortical , Teste de Materiais , Fenômenos Mecânicos , Animais , Bovinos , Fatores de Tempo , Fenômenos Biomecânicos , Testes Mecânicos , Manejo de Espécimes
8.
J Orthop Surg Res ; 19(1): 380, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38943143

RESUMO

PURPOSE: To compare the efficacy and safety of cortical bone trajectory (CBT) screw and pedicle screw (PS) internal fixation in the treatment of adjacent segment degeneration (ASD) after lumbar fusion. METHODS: This study was registered on International Prospective Register of Systematic Reviews (PROSPERO) (ID: CRD42023484937). We searched PubMed, Embase, Web of Science, Cochrane Library, China National Knowledge Infrastructure (CNKI), Wan Fang Database, and Wei Pu Database by computer to collect controlled clinical studies on the efficacy and safety of cortical bone trajectory (CBT) screw and pedicle screw (PS) internal fixation in the treatment of adjacent segment degeneration (ASD) after lumbar fusion from database establishment to November 2023. Two researchers screened the literature, extracted data and evaluated the risk of bias of the included studies, recorded the authors, and sample size, and extracted the intraoperative blood loss, operation time, Oswestry disability index (ODI), Visual analogue scale (VAS), disc height (DH), hospital length stay and complications in each study. Meta-analysis was performed using Revman 5.4 software provided by Cochrane Library. RESULTS: A total of 6 cohort studies (CS) and 1 randomized controlled study with a total of 420 patients were included in this study, including 188 patients in the CBT group and 232 patients in the PS group. The CBT group had lower intraoperative blood loss than the PS group [mean difference (MD) = -129.38, 95% CI (-177.22, -81.55), P < 0.00001] and operation time was shorter than that of the PS group [MD = -1.42, 95% CI (-2.63, -0.20), P = 0.02]. Early postoperative back and leg pain improved more significantly in the CBT group [MD = -0.77, 95% CI (-1.35, -0.19), P = 0.01; MD = -0.24, 95% CI (-0.37, -0.10), P = 0.0005]. CONCLUSION: Compared with PS, CBT for adjacent segment degeneration after lumbar fusion has the advantages of less intraoperative blood loss, shorter operation time, and less back and leg pain in the early postoperative period.


Assuntos
Osso Cortical , Vértebras Lombares , Parafusos Pediculares , Fusão Vertebral , Humanos , Fusão Vertebral/métodos , Fusão Vertebral/efeitos adversos , Osso Cortical/cirurgia , Vértebras Lombares/cirurgia , Resultado do Tratamento , Degeneração do Disco Intervertebral/cirurgia , Parafusos Ósseos , Duração da Cirurgia , Masculino , Feminino , Perda Sanguínea Cirúrgica
9.
Lasers Med Sci ; 39(1): 157, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38879698

RESUMO

Frequently orthopedic surgeries require mechanical drilling processes especially for inserted biodegradable screws or removing small bone lesions. However mechanical drilling techniques induce large number of forces as well as have substantially lower material removal rates resulting in prolong healing times. This study focuses on analyzing the impact of quasi-continuous laser drilling on the bone's surface as well as optimizing the drilling conditions to achieve high material removal rates. An ex-vivo study was conducted on the cortical region of desiccated bovine bone. The laser-based drilling on the bovine bine specimens was conducted in an argon atmosphere using a number of laser pulses ranging from 100 to 15,000. The morphology of the resulting laser drilled cavities was characterized using Energy dispersive Spectroscopy (EDS) and the width and depth of the drills were measured using a laser based Profilometer. Data from the profilometer was then used to calculate material removal rates. At last, the material removal rates and laser processing parameters were used to develop a statistical model based on Design of Experiments (DOE) approach to predict the optimal laser drilling parameters. The main outcome of the study based on the laser drilled cavities was that as the number of laser pulses increases, the depth and diameter of the cavities progressively increase. However, the material removal rates revealed a decrease in value at a point between 4000 and 6000 laser pulses. Therefore, based on the sequential sum of square method, a polynomial curve to the 6th power was fit to the experimental data. The predicted equation of the curve had a p-value of 0.0010 indicating statistical significance and predicted the maximum material removal rate to be 32.10 mm3/s with 95%CI [28.3,35.9] which was associated with the optimum number of laser pulses of 4820. Whereas the experimental verification of bone drilling with 4820 laser pulses yielded a material removal rate of 33.37 mm3/s. Therefore, this study found that the carbonized layer formed due to laser processing had a decreased carbon content and helped in increasing the material removal rate. Then using the experimental data, a polymetric equation to the sixth power was developed which predicted the optimized material removal rate to occur at 4820 pulses.


Assuntos
Osso Cortical , Terapia a Laser , Animais , Bovinos , Osso Cortical/cirurgia , Osso Cortical/efeitos da radiação , Terapia a Laser/métodos , Terapia a Laser/instrumentação , Espectrometria por Raios X , Procedimentos Ortopédicos/métodos , Procedimentos Ortopédicos/instrumentação
11.
Comput Biol Med ; 178: 108708, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38861895

RESUMO

BACKGROUND: High-performance polymers are used in different fixed prosthesis treatments due to their many advantages such as biocompatibility, shock absorption ability, high fracture resistance. The effects of marginal design on the forces on high-performance polymers are unknown. This study aimed was to investigate the stress distribution of different marginal designs on Polyetheretherketone (PEEK) and Polyetherketoneketone (PEKK) substructure materials, cortical bone and cancellous bone by finite element analysis. METHODS: A first maxillary molar tooth was modeled in 3D using the "3D Complex Render" method. Considering the ideal preparation conditions (Taper angle was 6°, step depth was 1 mm, occlusal reduction was 2 mm), four different configurations were modeled by changing the marginal design (chamfer, deep chamfer, shoulder 90°, shoulder 135°). PEEK, PEKK substructure, and composite superstructure were designed on created models. A total of 150 N oblique force from two points and a total of 300 N vertical force from three points were applied from occlusall. and the maximum principal stress, minimum principal stress, von Mises stress findings in the cortical bone, spongiose bone, and substructure were examined. The study was carried out by static linear analysis with a three-dimensional finite element stress analysis method. RESULTS: The highest maximum principal stress value in the cortical bone was observed when the PEEK + Shoulder 135° step at vertical force. The highest minimum principal stress value in the cortical bone was observed when the PEEK + Shoulder 90° step, and PEEK + deep chamfer step at oblique force. The highest maximum principal stress value in spongiose bone was observed when the PEEK + Shoulder 90° step. The highest minimum principal stress value in spongiose bone was observed when the PEEK + deep chamfer step at vertical force. The highest von Mises stress value in the substructure was observed when the PEKK + Deep chamfer step at oblique force. The lowest maximum principal stress value in the cortical bone was observed when the PEKK + Shoulder 135° step at oblique force. The lowest minimum principal stress value in the cortical bone was observed when the PEEK + Shoulder 135° step, and PEKK + shoulder 135° step at vertical force. The lowest maximum principal stress value in spongiose bone was observed when the PEEK + Shoulder 90° step. The lowest minimum principal stress value in spongiose bone was observed when the PEEK + Shoulder 135° step and PEKK + Shoulder 135° step at vertical force. The lowest von Mises stress value in the substructure was observed when the PEEK + Deep chamfer step at vertical force. CONCLUSION: When cortical and spongiose bone stress were evaluated, no destructive stress was observed. Considering the stresses occurring in the substructure the highest stress was observed in the chamfer step.


Assuntos
Benzofenonas , Osso Cortical , Análise de Elementos Finitos , Cetonas , Polietilenoglicóis , Polímeros , Humanos , Osso Cortical/fisiologia , Polietilenoglicóis/química , Osso Esponjoso/fisiologia , Estresse Mecânico
12.
J Robot Surg ; 18(1): 204, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38714574

RESUMO

Workflow for cortical bone trajectory (CBT) screws includes tapping line-to-line or under tapping by 1 mm. We describe a non-tapping, two-step workflow for CBT screw placement, and compare the safety profile and time savings to the Tap (three-step) workflow. Patients undergoing robotic assisted 1-3 level posterior fusion with CBT screws for degenerative conditions were identified and separated into either a No-Tap or Tap workflow. Number of total screws, screw-related complications, estimated blood loss, operative time, robotic time, and return to the operating room were collected and analyzed. There were 91 cases (458 screws) in the No-Tap and 88 cases (466 screws) in the Tap groups, with no difference in demographics, revision status, ASA grade, approach, number of levels fused or diagnosis between cohorts. Total robotic time was lower in the No-Tap (26.7 min) versus the Tap group (30.3 min, p = 0.053). There was no difference in the number of malpositioned screws identified intraoperatively (10 vs 6, p = 0.427), screws converted to freehand (3 vs 3, p = 0.699), or screws abandoned (3 vs 2, p = 1.000). No pedicle/pars fracture or fixation failure was seen in the No-Tap cohort and one in the Tap cohort (p = 1.00). No patients in either cohort were returned to OR for malpositioned screws. This study showed that the No-Tap screw insertion workflow for robot-assisted CBT reduces robotic time without increasing complications.


Assuntos
Osso Cortical , Procedimentos Cirúrgicos Robóticos , Fusão Vertebral , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Masculino , Feminino , Pessoa de Meia-Idade , Osso Cortical/cirurgia , Idoso , Fusão Vertebral/métodos , Fusão Vertebral/instrumentação , Duração da Cirurgia , Parafusos Ósseos , Fluxo de Trabalho , Parafusos Pediculares , Adulto
13.
J Mech Behav Biomed Mater ; 155: 106577, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38759587

RESUMO

The present study simulates the fracture behavior of diabetic cortical bone with high levels of advanced glycation end-products (AGEs) under dynamic loading. We consider that the increased AGEs in diabetic cortical bone degrade the materials heterogeneity of cortical bone through a reduction in critical energy release rates of the microstructural features. To simulate the initiation and propagation of cracks, we implement a phase field fracture framework on 2D models of human tibia cortical microstructure. The simulations show that the mismatch between the fracture properties (e.g., critical energy release rate) of osteons and interstitial tissue due to high AGEs contents can change crack growth trajectories. The results show crack branching in the cortical microstructure under dynamic loading is affected by the mismatches related to AGEs. In addition, we observe cortical features such as osteons and cement lines can prevent multiple cracking under dynamic loading even with changing the mismatches due to high AGEs. Furthermore, under dynamic loading, some toughening mechanisms can be activated and deactivated with different AGEs contents. In conclusion, the current findings present that the combination of the loading type and materials heterogeneity of microstructural features can change the fracture response of diabetic cortical bone and its fragility.


Assuntos
Osso Cortical , Produtos Finais de Glicação Avançada , Suporte de Carga , Humanos , Osso Cortical/metabolismo , Produtos Finais de Glicação Avançada/metabolismo , Fenômenos Biomecânicos , Fraturas Ósseas/metabolismo , Tíbia/metabolismo , Análise de Elementos Finitos , Estresse Mecânico
14.
Int J Implant Dent ; 10(1): 23, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38713411

RESUMO

PURPOSE: To analyze the visibility of the maxillary sinus septa (MSS) in panoramic radiography (PR) versus cone beam computed tomography (CBCT) and to investigate whether the buccal cortical bone thickness (BT) or the septa dimensions influence their visibility. METHODS: Corresponding PR and CBCT images of 355 patients were selected and examined for MSS visibility. The septa dimensions (width, height, depth) and the BT were measured. Results were analysed statistically. RESULTS: Comparing the corresponding regions on CBCT and PR, 170 MSS were identified; however, only 106 of these were also visible using PR. The MSS visibility was significantly higher on CBCT versus PR images (P1: p = 0.039, P2: p = 0.015, M1: p = 0.041, M2: p = 0.017, M3: p = 0.000), except region C (p = 0.625). Regarding the measurements of MSS dimensions, only the height in region M1 (p = 0.013) and the width in region P2 (p = 0.034) were significantly more visible on CBCT. The BT in the area of the MSS was found to have a marginal influence on its visibility on the PR images only in regions M3 and M1 (M3: p = 0.043, M1: p = 0.047). In terms of MSS visibility based on the dimensions, significance was found for all three influencing variables only in region P2 (width; p = 0.041, height; p = 0.001, depth; p = 0.007). There were only isolated cases of further significance: M3 for width (p = 0.043), M2 for height (p = 0.024), and P1 for depth (p = 0.034), no further significance was noted. CONCLUSION: MSS visibility appears significantly higher on CBCT versus PR images. It is concluded that the septa dimensions and BT can influence MSS visibility on PR images just in certain regions.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Osso Cortical , Seio Maxilar , Radiografia Panorâmica , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Radiografia Panorâmica/métodos , Seio Maxilar/diagnóstico por imagem , Seio Maxilar/anatomia & histologia , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Osso Cortical/diagnóstico por imagem , Osso Cortical/anatomia & histologia , Idoso , Adulto Jovem , Idoso de 80 Anos ou mais
15.
Acta Biomater ; 182: 139-155, 2024 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-38750914

RESUMO

Additively manufactured (AM) biodegradable zinc (Zn) alloys have recently emerged as promising porous bone-substituting materials, due to their moderate degradation rates, good biocompatibility, geometrically ordered microarchitectures, and bone-mimicking mechanical properties. While AM Zn alloy porous scaffolds mimicking the mechanical properties of trabecular bone have been previously reported, mimicking the mechanical properties of cortical bone remains a formidable challenge. To overcome this challenge, we developed the AM Zn-3Mg alloy. We used laser powder bed fusion to process Zn-3Mg and compared it with pure Zn. The AM Zn-3Mg alloy exhibited significantly refined grains and a unique microstructure with interlaced α-Zn/Mg2Zn11 phases. The compressive properties of the solid Zn-3Mg specimens greatly exceeded their tensile properties, with a compressive yield strength of up to 601 MPa and an ultimate strain of >60 %. We then designed and fabricated functionally graded porous structures with a solid core and achieved cortical bone-mimicking mechanical properties, including a compressive yield strength of >120 MPa and an elastic modulus of ≈20 GPa. The biodegradation rates of the Zn-3Mg specimens were lower than those of pure Zn and could be adjusted by tuning the AM process parameters. The Zn-3Mg specimens also exhibited improved biocompatibility as compared to pure Zn, including higher metabolic activity and enhanced osteogenic behavior of MC3T3 cells cultured with the extracts from the Zn-3Mg alloy specimens. Altogether, these results marked major progress in developing AM porous biodegradable metallic bone substitutes, which paved the way toward clinical adoption of Zn-based scaffolds for the treatment of load-bearing bony defects. STATEMENT OF SIGNIFICANCE: Our study presents a significant advancement in the realm of biodegradable metallic bone substitutes through the development of an additively manufactured Zn-3Mg alloy. This novel alloy showcases refined grains and a distinctive microstructure, enabling the fabrication of functionally graded porous structures with mechanical properties resembling cortical bone. The achieved compressive yield strength and elastic modulus signify a critical leap toward mimicking the mechanical behavior of load-bearing bone. Moreover, our findings reveal tunable biodegradation rates and enhanced biocompatibility compared to pure Zn, emphasizing the potential clinical utility of Zn-based scaffolds for treating load-bearing bony defects. This breakthrough opens doors for the wider adoption of zinc-based materials in regenerative orthopedics.


Assuntos
Ligas , Osso Cortical , Zinco , Ligas/química , Ligas/farmacologia , Zinco/química , Zinco/farmacologia , Animais , Camundongos , Osso Cortical/efeitos dos fármacos , Porosidade , Magnésio/química , Magnésio/farmacologia , Teste de Materiais , Força Compressiva , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Materiais Biomiméticos/química , Materiais Biomiméticos/farmacologia , Implantes Absorvíveis , Módulo de Elasticidade , Linhagem Celular
16.
Eur J Oral Sci ; 132(4): e12992, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38771146

RESUMO

Finite element analysis (FEA) has been used to analyze the behavior of dental materials, mainly in implantology. However, FEA is a mechanical analysis and few studies have tried to simulate the biological characteristics of the healing process of loaded implants. This study used the rule of mixtures to simulate the biological healing process of immediate implants in an alveolus socket and bone-implant junction interface through FEA. Three-dimensional geometric models of the structures were obtained, and material properties were derived from the literature. The rule of mixtures was used to simulate the healing periods-immediate and early loading, in which the concentration of each cell type, based on in vivo studies, influenced the final elastic moduli. A 100 N occlusal load was simulated in axial and oblique directions. The models were evaluated for maximum and minimum principal strains, and the bone overload was assessed through Frost's mechanostat. There was a higher strain concentration in the healing regions and cortical bone tissue near the cervical portion. The bone overload was higher in the immediate load condition. The method used in this study may help to simulate the biological healing process and could be useful to relate FEA results to clinical practice.


Assuntos
Implantes Dentários , Módulo de Elasticidade , Análise de Elementos Finitos , Carga Imediata em Implante Dentário , Alvéolo Dental , Cicatrização , Humanos , Alvéolo Dental/fisiologia , Cicatrização/fisiologia , Fenômenos Biomecânicos , Simulação por Computador , Interface Osso-Implante/fisiologia , Estresse Mecânico , Processo Alveolar/fisiologia , Modelos Biológicos , Osseointegração/fisiologia , Força de Mordida , Análise do Estresse Dentário/métodos , Osteoblastos/fisiologia , Osso Cortical/fisiologia , Imageamento Tridimensional/métodos
17.
J Histochem Cytochem ; 72(5): 309-327, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38725403

RESUMO

To clarify the cellular mechanism of cortical porosity induced by intermittent parathyroid hormone (PTH) administration, we examined the femoral cortical bone of mice that received 40 µg/kg/day (four times a day) human PTH (hPTH) (1-34). The PTH-driven cortical porosity initiated from the metaphyseal region and chronologically expanded toward the diaphysis. Alkaline phosphatase (ALP)-positive osteoblasts in the control mice covered the cortical surface, and endomucin-positive blood vessels were distant from these osteoblasts. In PTH-administered mice, endomucin-reactive blood vessels with TRAP-positive penetrated the ALP-positive osteoblast layer, invading the cortical bone. Statistically, the distance between endomucin-positive blood vessels and the cortical bone surface abated after PTH administration. Transmission electron microscopic observation demonstrated that vascular endothelial cells often pass through the flattened osteoblast layer and accompanied osteoclasts in the deep region of the cortical bone. The cell layers covering mature osteoblasts thickened with PTH administration and exhibited ALP, α-smooth muscle actin (αSMA), vascular cell adhesion molecule-1 (VCAM1), and receptor activator of NF-κB ligand (RANKL). Within these cell layers, osteoclasts were found near endomucin-reactive blood vessels. In PTH-administered femora, osteocytes secreted Dkk1, a Wnt inhibitor that affects angiogenesis, and blood vessels exhibited plasmalemma vesicle-associated protein, an angiogenic molecule. In summary, endomucin-positive blood vessels, when accompanied by osteoclasts in the ALP/αSMA/VCAM1/RANKL-reactive osteoblastic cell layers, invade the cortical bone, potentially due to the action of osteocyte-derived molecules such as DKK1.


Assuntos
Osso Cortical , Células Endoteliais , Hormônio Paratireóideo , Animais , Humanos , Masculino , Camundongos , Osso Cortical/efeitos dos fármacos , Osso Cortical/metabolismo , Células Endoteliais/efeitos dos fármacos , Células Endoteliais/metabolismo , Fêmur/efeitos dos fármacos , Fêmur/irrigação sanguínea , Fêmur/metabolismo , Imuno-Histoquímica , Osteoblastos/efeitos dos fármacos , Osteoblastos/metabolismo , Hormônio Paratireóideo/farmacologia , Porosidade
18.
Jt Dis Relat Surg ; 35(2): 417-421, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38727123

RESUMO

Although hemangiomas are the most common soft tissue tumors, intramuscular hemangiomas account for only 0.8% of all vascular tumors. These lesions are rarely located adjacent to the bone and cause changes in the adjacent bone. They are often mistakenly diagnosed as bone tumors. In this study, a case of a 19-year-old male patient with intramuscular hemangioma causing cortical thickening was reported.


Assuntos
Neoplasias Ósseas , Hemangioma , Hipertrofia , Neoplasias Musculares , Humanos , Masculino , Hemangioma/patologia , Hemangioma/diagnóstico , Hemangioma/diagnóstico por imagem , Diagnóstico Diferencial , Adulto Jovem , Neoplasias Ósseas/diagnóstico , Neoplasias Ósseas/patologia , Neoplasias Musculares/patologia , Neoplasias Musculares/diagnóstico por imagem , Neoplasias Musculares/diagnóstico , Hipertrofia/patologia , Imageamento por Ressonância Magnética , Osso Cortical/patologia , Osso Cortical/diagnóstico por imagem , Tomografia Computadorizada por Raios X
19.
Clin Oral Investig ; 28(6): 336, 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38795258

RESUMO

OBJECTIVE: Stress distribution assessment by finite elements analysis in poly(etheretherketone) (PEEK) implant and abutment as retainers of single crowns in the anterior region. MATERIALS AND METHODS: Five 3D models were created, varying implant/abutment manufacturing materials: titanium (Ti), zirconia (Zr), pure PEEK (PEEKp), carbon fiber-reinforced PEEK (PEEKc), glass fiber-reinforced PEEK (PEEKg). A 50 N load was applied 30o off-axis at the incisal edge of the upper central incisor. The Von Mises stress (σvM) was evaluated on abutment, implant/screw, and minimum principal stress (σmin) and maximum shear stress (τmax) for cortical and cancellous bone. RESULTS: The abutment σvM lowest stress was observed in PEEKp group, being 70% lower than Ti and 74% than Zr. On the implant, PEEKp reduced 68% compared to Ti and a 71% to Zr. In the abutment screws, an increase of at least 33% was found in PEEKc compared to Ti, and of at least 81% to Zr. For cortical bone, the highest τmax values were in the PEEKp group, and a slight increase in stress was observed compared to all PEEK groups with Ti and Zr. For σmin, the highest stress was found in the PEEKc. Stress increased at least 7% in cancellous bone for all PEEK groups. CONCLUSION: Abutments and implants made by PEEKc concentrate less σvM stress, transmitting greater stress to the cortical and medullary bone. CLINICAL RELEVANCE: The best stress distribution in PEEKc components may contribute to decreased stress shielding; in vitro and in vivo research is recommended to investigate this.


Assuntos
Benzofenonas , Coroas , Dente Suporte , Análise do Estresse Dentário , Análise de Elementos Finitos , Cetonas , Teste de Materiais , Polietilenoglicóis , Polímeros , Titânio , Zircônio , Cetonas/química , Polietilenoglicóis/química , Humanos , Zircônio/química , Titânio/química , Fibra de Carbono/química , Projeto do Implante Dentário-Pivô , Incisivo , Materiais Dentários/química , Implantes Dentários para Um Único Dente , Osso Cortical , Vidro/química , Planejamento de Prótese Dentária
20.
Bone Joint J ; 106-B(6): 548-554, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38821498

RESUMO

Aims: The aim of this study was to compare the pattern of initial fixation and changes in periprosthetic bone mineral density (BMD) between patients who underwent total hip arthroplasty (THA) using a traditional fully hydroxyapatite (HA)-coated stem (T-HA group) and those with a newly introduced fully HA-coated stem (N-HA group). Methods: The study included 36 patients with T-HA stems and 30 with N-HA stems. Dual-energy X-ray absorptiometry was used to measure the change in periprosthetic BMD, one and two years postoperatively. The 3D contact between the stem and femoral cortical bone was evaluated using a density-mapping system, and clinical assessment, including patient-reported outcome measurements, was recorded. Results: There were significantly larger contact areas in Gruen zones 3, 5, and 6 in the N-HA group than in the T-HA group. At two years postoperatively, there was a significant decrease in BMD around the proximal-medial femur (zone 6) in the N-HA group and a significant increase in the T-HA group. BMD changes in both groups correlated with BMI or preoperative lumbar BMD rather than with the extent of contact with the femoral cortical bone. Conclusion: The N-HA-coated stem showed a significantly larger contact area, indicating a distal fixation pattern, compared with the traditional fully HA-coated stem. The T-HA-coated stem showed better preservation of periprosthetic BMD, two years postoperatively. Surgeons should consider these patterns of fixation and differences in BMD when selecting fully HA-coated stems for THA, to improve the long-term outcomes.


Assuntos
Absorciometria de Fóton , Artroplastia de Quadril , Densidade Óssea , Materiais Revestidos Biocompatíveis , Osso Cortical , Durapatita , Fêmur , Prótese de Quadril , Desenho de Prótese , Humanos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Fêmur/cirurgia , Osso Cortical/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA