Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 14.311
Filtrar
1.
BMC Vet Res ; 20(1): 319, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39014383

RESUMO

BACKGROUND: Monitoring blood oxygenation is essential in immobilised rhinoceros, which are susceptible to opioid-induced hypoxaemia. This study assessed the reliability, clinical performance and trending ability of the Nonin PalmSAT 2500 A pulse oximeter's and the Masimo Radical-7 pulse co-oximeter's dual-wavelength technology, with their probes placed at two measurement sites, the inner surface of the third-eyelid and the scarified ear pinna of immobilised white rhinoceroses. Eight white rhinoceros were immobilised with etorphine-based drug combinations and given butorphanol after 12 min, and oxygen after 40 min, of recumbency. The Nonin and Masimo devices, with dual-wavelength probes attached to the third-eyelid and ear recorded arterial peripheral oxygen-haemoglobin saturation (SpO2) at pre-determined time points, concurrently with measurements of arterial oxygen-haemoglobin saturation (SaO2), from drawn blood samples, by a benchtop AVOXimeter 4000 co-oximeter (reference method). Reliability of the Nonin and Masimo devices was evaluated using the Bland-Altman and the area root mean squares (ARMS) methods. Clinical performance of the devices was evaluated for their ability to accurately detect clinical hypoxemia using receiver operating characteristic (ROC) curves and measures of sensitivity, specificity, and positive and negative predictive values. Trending ability of the devices was assessed by calculating concordance rates from four-quadrant plots. RESULTS: Only the Nonin device with transflectance probe attached to the third-eyelid provided reliable SpO2 measurements across the 70 to 100% saturation range (bias - 1%, precision 4%, ARMS 4%). Nonin and Masimo devices with transflectance probes attached to the third-eyelid both had high clinical performance at detecting clinical hypoxaemia [area under the ROC curves (AUC): 0.93 and 0.90, respectively]. However, the Nonin and Masimo devices with transmission probes attached to the ear were unreliable and provided only moderate clinical performance. Both Nonin and Masimo devices, at both measurement sites, had concordance rates lower than the recommended threshold of ≥ 90%, indicating poor trending ability. CONCLUSIONS: The overall assessment of reliability, clinical performance and trending ability indicate that the Nonin device with transflectance probe attached to the third-eyelid is best suited for monitoring of blood oxygenation in immobilised rhinoceros. The immobilisation procedure may have affected cardiovascular function to an extent that it limited the devices' performance.


Assuntos
Oximetria , Oxigênio , Perissodáctilos , Animais , Perissodáctilos/sangue , Oximetria/veterinária , Oximetria/instrumentação , Oximetria/métodos , Reprodutibilidade dos Testes , Oxigênio/sangue , Masculino , Imobilização/veterinária , Imobilização/instrumentação , Imobilização/métodos , Feminino
2.
BMC Musculoskelet Disord ; 25(1): 469, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38879465

RESUMO

PURPOSE: The aim of this study was to compare the clinical outcomes between patients with chronic ankle instability (CAI) undergoing arthroscopic anterior talofibular ligament (ATFL) repair who received elastic bandage treatment and those who received lower-leg cast immobilization. METHODS: CAI patients with isolated ATFL injury undergoing arthroscopic ATFL repair from January 2017 and August 2019 were included in the study. The visual analogue scale (VAS) at rest and during activities, American Orthopedic Foot and Ankle Society (AOFAS) score, Karlsson Ankle Functional Score (Karlsson score), and time of returning to walk, walk normally, work and sports were evaluated preoperatively, and at 6 months and 12 months follow-up. RESULTS: A total of 41 patients were included in this study. Among them, 24 patients accepted lower-leg cast fixation, and the other 17 patients were immobilized with elastic bandage. Compared to patients with lower-leg immobilization, patients with elastic bandage fixation had significantly lower VAS during activities (P = 0.021) and higher AOFAS score (P = 0.015) at 12 months follow-up. The Karlsson score at 6 months follow-up were significantly higher in elastic bandage group than those in lower-leg group (P = 0.011). However, no significant difference was observed in time of returning to walk, work and sports between the two groups. CONCLUSION: Elastic bandage treatment was better than lower-leg cast immobilization in terms of eliminating pain symptom at 12 months follow-up, and improving ankle functional outcome at 6 months follow-up. Moreover, the present study emphasized that lower-leg cast immobilization offered no advantages in arthroscopic ATFL repair postoperative immobilization. STUDY DESIGN: Cohort study; Level of evidence, 3.


Assuntos
Moldes Cirúrgicos , Instabilidade Articular , Ligamentos Laterais do Tornozelo , Humanos , Feminino , Masculino , Adulto , Ligamentos Laterais do Tornozelo/cirurgia , Ligamentos Laterais do Tornozelo/lesões , Resultado do Tratamento , Instabilidade Articular/cirurgia , Adulto Jovem , Articulação do Tornozelo/cirurgia , Articulação do Tornozelo/fisiopatologia , Artroscopia/métodos , Estudos Retrospectivos , Traumatismos do Tornozelo/cirurgia , Traumatismos do Tornozelo/terapia , Imobilização/métodos , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Seguimentos
3.
Cancer Radiother ; 28(3): 229-235, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38871604

RESUMO

PURPOSE: The main objective of this study was to assess inter- and intrafraction errors for two patient immobilisation devices in the context of lung stereotactic body radiation therapy: a vacuum cushion and a simple arm support. MATERIALS AND METHODS: Twenty patients who were treated with lung stereotactic body radiation therapy in supine position with arms above their head were included in the study. Ten patients were setup in a vacuum cushion (Bluebag™, Elekta) and ten other patients with a simple arm support (Posirest™, Civco). A pretreatment four-dimensional cone-beam computed tomography and a post-treatment three-dimensional cone-beam computed tomography were acquired to compare positioning and immobilisation accuracy. Based on a rigid registration with the planning computed tomography on the spine at the target level, translational and rotational errors were reported. RESULTS: The median number of fractions per treatment was 5 (range: 3-10). Mean interfraction errors based on 112 four-dimensional cone-beam computed tomographies were similar for both setups with deviations less than or equal to 1.3mm in lateral and vertical direction and 1.2° in roll and yaw. For longitudinal translational errors, mean interfraction errors were 0.7mm with vacuum cushion and -3.9mm with arm support. Based on 111 three-dimensional cone-beam computed tomographies, mean lateral, longitudinal and vertical intrafraction errors were -0.1mm, -0.2mm and 0.0mm respectively (SD: 1.0, 1.2 and 1.0mm respectively) for the patients setup with vacuum cushion, and mean vertical, longitudinal and lateral intrafraction errors were -0.3mm, -0.7mm and 0.1mm respectively (SD: 2.3, 1.8 and 1.4mm respectively) for the patients setup with arm support. Intrafraction errors means were not statistically different between both positions but standard deviations were statistically larger with arm support. CONCLUSION: The results of our study showed similar inter and intrafraction mean deviations between both positioning but a large variability in intrafraction observed with arm support suggested a more accurate immobilization with vacuum cushion.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Imobilização , Neoplasias Pulmonares , Posicionamento do Paciente , Radiocirurgia , Humanos , Radiocirurgia/métodos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Imobilização/métodos , Imobilização/instrumentação , Estudos Prospectivos , Idoso , Feminino , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada de Feixe Cônico/métodos , Idoso de 80 Anos ou mais , Erros de Configuração em Radioterapia/prevenção & controle , Fracionamento da Dose de Radiação , Decúbito Dorsal , Tomografia Computadorizada Quadridimensional/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Vácuo
4.
Bull Exp Biol Med ; 176(6): 722-726, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38888650

RESUMO

We studied the effect of separate and combined influence of chronic forced physical activity reduction and high-fat and high-carbohydrate diet containing cholesterol on some indicators of carbohydrate, lipid, and cholesterol metabolism in growing male Wistar rats. Used combination of factors simulating a sedentary lifestyle and unhealthy diet did not have a synergistic effect on the selected biomarkers. On the contrary, the effect was antagonistic: body weight and appetite decreased and insulin resistance increased. The obtained results indicate certain prospects of hypercholesterolemia model using in preclinical studies of specialized food products to optimize the diet of individuals with disorders of carbohydrate and lipid metabolism.


Assuntos
Colesterol , Dieta Hiperlipídica , Metabolismo dos Lipídeos , Ratos Wistar , Animais , Masculino , Ratos , Dieta Hiperlipídica/efeitos adversos , Metabolismo dos Lipídeos/efeitos dos fármacos , Colesterol/metabolismo , Colesterol/sangue , Resistência à Insulina , Peso Corporal/efeitos dos fármacos , Carboidratos da Dieta/administração & dosagem , Carboidratos da Dieta/farmacologia , Hipercolesterolemia/metabolismo , Hipercolesterolemia/dietoterapia , Imobilização , Colesterol na Dieta/administração & dosagem , Apetite/efeitos dos fármacos , Apetite/fisiologia , Condicionamento Físico Animal/fisiologia
5.
Clin Sci (Lond) ; 138(12): 741-756, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38895777

RESUMO

Periods of skeletal muscle disuse lead to rapid declines in muscle mass (atrophy), which is fundamentally underpinned by an imbalance between muscle protein synthesis (MPS) and muscle protein breakdown (MPB). The complex interplay of molecular mechanisms contributing to the altered regulation of muscle protein balance during disuse have been investigated but rarely synthesised in the context of humans. This narrative review discusses human models of muscle disuse and the ensuing inversely exponential rate of muscle atrophy. The molecular processes contributing to altered protein balance are explored, with a particular focus on growth and breakdown signalling pathways, mitochondrial adaptations and neuromuscular dysfunction. Finally, key research gaps within the disuse atrophy literature are highlighted providing future avenues to enhance our mechanistic understanding of human disuse atrophy.


Assuntos
Proteínas Musculares , Músculo Esquelético , Atrofia Muscular , Humanos , Músculo Esquelético/metabolismo , Músculo Esquelético/patologia , Atrofia Muscular/metabolismo , Atrofia Muscular/patologia , Proteínas Musculares/metabolismo , Transdução de Sinais , Imobilização/efeitos adversos , Transtornos Musculares Atróficos/metabolismo , Transtornos Musculares Atróficos/patologia , Transtornos Musculares Atróficos/fisiopatologia
6.
Sci Rep ; 14(1): 13460, 2024 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-38862648

RESUMO

In conservative treatment for proximal humerus fractures (PHFs), the immobilization position of the affected arm should not be determined uniformly. The aim of this study is to investigate the optimal immobilization position for conservative treatment of different types of PHFs. We hypothesized that the optimal position minimizing the deforming force in PHFs depends on the fracture components involved. PHF models involving either the surgical neck (SN) or greater tuberosity (GT) were created using 12 fresh-frozen cadaveric shoulders. In the SN model, the deforming forces on the pectoralis major muscle were measured in full adduction by increasing external rotation. In the GT model, the deforming force of the supraspinatus muscle was measured in neutral rotation by decreasing abduction, and the deforming force of the infraspinatus muscle was measured in full adduction by increasing internal rotation, respectively. In the SN model, the deforming force of the pectoralis major muscle increased significantly with external rotation from full internal rotation to neutral rotation (P = 0.006), indicating that the arm should be placed in full internal rotation. In the GT model, the deforming force of the supraspinatus muscle increased significantly with adduction from 45° of abduction to full adduction (P = 0.006); the deforming force of the infraspinatus muscle increased significantly with internal rotation from neutral rotation to full internal rotation (P = 0.006). These findings should be considered when placing the arm in abduction and neutral rotation so as to minimize the deforming force by either the supra or infraspinatus muscle. In conservative treatment for PHFs, the affected arm should be placed in a position that minimizes the deforming force on the fracture components involved.


Assuntos
Cadáver , Tratamento Conservador , Fraturas do Ombro , Humanos , Fraturas do Ombro/terapia , Fenômenos Biomecânicos , Idoso , Masculino , Feminino , Tratamento Conservador/métodos , Idoso de 80 Anos ou mais , Imobilização/métodos , Pessoa de Meia-Idade , Amplitude de Movimento Articular
7.
Eur Rev Med Pharmacol Sci ; 28(11): 3771-3780, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38884512

RESUMO

OBJECTIVE: Fractures of the proximal humerus (PHF) are commonly treated conservatively. Evidence suggests that a period of immobilization of one week or less may lead to some advantages compared to a traditional 3-4 weeks of immobilization. The purpose of this systematic review was to assess the clinical and radiological results in the case of early rehabilitation vs. delayed rehabilitation after PHF. MATERIALS AND METHODS: In July 2023, a literature search was carried out on the PubMed, MEDLINE, and Embase databases to identify all the randomized trials comparing early rehabilitation vs. delayed rehabilitation after PHF. The following data were extracted from each included study: patients' demographics, study design and level of evidence, follow-up times, treatment groups, evaluation scores adopted, and overall clinical and radiological findings. The quality of the trials was assessed using the Cochrane Risk of Bias Assessment. RESULTS: A total of 5 studies, including 378 patients and dealing with early vs. delayed rehabilitation in case of conservative treatment of PHF, were included in this study. Early rehabilitation was started within 1 week and consisted mainly of pendulum exercise and progressive passive mobilization. Early rehabilitation was associated with better pain and functional scores within the first 3 months in 3 studies. No difference in pain or function was reported at 6 months or longer follow-up, and no differences in complications rate were observed between early vs. delayed rehabilitation groups. CONCLUSIONS: This systematic review suggests that early mobilization within one week in case of conservative treatment of PHF leads to improved function recovery and reduced pain, especially in the first months of rehabilitation, without differences at longer follow-up and without increasing complications rate. Reducing immobilization time could accelerate function recovery and regaining independence in daily life activities.


Assuntos
Imobilização , Fraturas do Ombro , Humanos , Fraturas do Ombro/reabilitação , Fraturas do Ombro/terapia , Tratamento Conservador , Fatores de Tempo
8.
Exp Biol Med (Maywood) ; 249: 10037, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38854792

RESUMO

In-ovo imaging using avian eggs has been described as a potential alternative to animal testing using rodents. However, imaging studies are hampered by embryonal motion producing artifacts. This study aims at systematically comparing isoflurane, desflurane and sevoflurane in three different concentrations in ostrich embryos. Biomagnetic signals of ostrich embryos were recorded analyzing cardiac action and motion. Ten groups comprising eight ostrich embryos each were investigated: Control, isoflurane (2%, 4%, and 6%), desflurane (6%, 12%, and 18%) and sevoflurane (3%, 5%, and 8%). Each ostrich egg was exposed to the same narcotic gas and concentration on development day (DD) 31 and 34. Narcotic gas exposure was upheld for 90 min and embryos were monitored for additional 75 min. Toxicity was evaluated by verifying embryo viability 24 h after the experiments. Initial heart rate of mean 148 beats/min (DD 31) and 136 beats/min (DD 34) decreased over time by 44-48 beats/minute. No significant differences were observed between groups. All narcotic gases led to distinct movement reduction after mean 8 min. Embryos exposed to desflurane 6% showed residual movements. Isoflurane 6% and sevoflurane 8% produced motion-free time intervals of mean 70 min after discontinuation of narcotic gas exposure. Only one embryo death occurred after narcotic gas exposure with desflurane 6%. This study shows that isoflurane, desflurane and sevoflurane are suitable for ostrich embryo immobilization, which is a prerequisite for motion-artifact free imaging. Application of isoflurane 6% and sevoflurane 8% is a) safe as no embryonal deaths occurred after exposure and b) effective as immobilization was observed for approx. 70 min after the end of narcotic gas exposure. These results should be interpreted with caution regarding transferability to other avian species as differences in embryo size and incubation duration exist.


Assuntos
Desflurano , Embrião não Mamífero , Isoflurano , Struthioniformes , Animais , Struthioniformes/embriologia , Embrião não Mamífero/efeitos dos fármacos , Anestésicos Inalatórios , Sevoflurano/efeitos adversos , Sevoflurano/farmacologia , Entorpecentes/toxicidade , Imobilização
9.
Ann R Coll Surg Engl ; 106(6): 478-484, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38787306

RESUMO

INTRODUCTION: Climate change is estimated to be the biggest global health threat of the 21st century, and has prompted calls to move away from processes in healthcare associated with high energy consumption and greenhouse gas emission. In musculoskeletal medicine, splints are widely used for limb immobilisation. These have typically been made from single-use materials such as gypsum, although in recent years purportedly environmentally friendly splints have been designed. In this systematic review, we set out to assess the clinical effectiveness of all commercially available environmentally friendly splinting materials, including Woodcast®. METHODS: The AMED (Allied and Complementary Medicine Database), CINAHL® (Cumulative Index to Nursing and Allied Health Literature), Cochrane Central Register of Controlled Trials, Embase®, Emcare® and MEDLINE® databases were searched to identify studies assessing the clinical effectiveness of biodegradable and environmentally friendly splints prior to paper review and data extraction. Formal quantitative synthesis was not possible owing to the substantial heterogeneity in the study designs and outcome measures. RESULTS: Six papers met the inclusion criteria, all investigating one particular splint material (Woodcast®). One was a case series, two were cohort studies and three were randomised controlled trials. Primary outcome measures were heterogeneous but the environmentally friendly splints were generally equivalent to traditional splint materials. Studies were mostly at a high risk of bias. CONCLUSIONS: There is limited research assessing 'green' splints in practice although the data suggest similarity with existing materials and no substantial safety concerns. Further scrutiny of the clinical effectiveness and environmental credentials of such splints is also required.


Assuntos
Contenções , Humanos , Imobilização/instrumentação , Imobilização/métodos
10.
Knee Surg Sports Traumatol Arthrosc ; 32(8): 2184-2193, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38796725

RESUMO

PURPOSE: The aim of the study was to examine the impact of a deep venous thrombosis (DVT) on patient outcomes 3 years after Achilles tendon rupture (ATR) repair and if there were continued improvements between 1 and 3 years after surgery. A secondary aim was to determine risk factors associated with impaired patient outcomes in the long term. METHODS: This cohort study consisted of 181 ATR-repaired patients, from two large randomized clinical trials, who attended a 3-year follow-up evaluation. Patients were postoperatively randomized to two different weight-bearing interventions compared with immobilization in a below-knee plaster cast for 2 weeks. During immobilization, screening for DVT was performed with Doppler ultrasound. At 1 and 3 years postoperatively, functional- and patient-reported outcomes were evaluated by the validated heel-rise test and self-reported questionnaire, Achilles tendon Total Rupture Score (ATRS). RESULTS: In total, 76 out of 181 (42%) patients exhibited a DVT at the 2- or 6-week screening after ATR surgery. Suffering from a DVT during immobilization resulted at 3 years in a worse limb symmetry index (LSI) of heel-rise total work compared to patients without DVT, adjusted for age (DVT mean LSI 68% vs. no DVT 78%, p = 0.027). At 3 years, patients with a DVT during immobilization displayed lower ATRS (DVT median 88 vs. no DVT 93, p = 0.046), which was not significant after adjustment for age. However, patients with DVT exhibited an improvement in ATRS, LSI total work, and LSI maximum height between 1 and 3 years, which was not seen among patients without DVT. Independent risk factors for reduced patient functional outcomes at 3 years were older age, greater calf muscle hypotrophy, and suffering a DVT. CONCLUSIONS: DVT during immobilization affects patients' long-term functional outcomes 3 years after ATR repair. Clinicians should adequately address risk factors contributing to impaired patient outcomes in the long term, including calf muscle hypotrophy, DVT, and older age. LEVEL OF EVIDENCE: Level Ⅲ.


Assuntos
Tendão do Calcâneo , Trombose Venosa , Humanos , Tendão do Calcâneo/cirurgia , Tendão do Calcâneo/lesões , Trombose Venosa/etiologia , Masculino , Feminino , Ruptura/cirurgia , Pessoa de Meia-Idade , Adulto , Fatores de Risco , Traumatismos dos Tendões/cirurgia , Imobilização , Complicações Pós-Operatórias/etiologia , Moldes Cirúrgicos , Suporte de Carga , Seguimentos
13.
J Orthop Surg Res ; 19(1): 282, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38711065

RESUMO

BACKGROUND: The aim of this study was to compare the effects of four different immobilization methods [single sugar tong splint (SSTS), double sugar tong splint (DSTS), short arm cast (SAC), and long arm cast (LAC)] commonly used for restricting forearm rotation in the upper extremity. METHODS: Forty healthy volunteers were included in the study. Dominant extremities were used for measurements. Basal pronation and supination of the forearm were measured with a custom-made goniometer, and the total rotation arc was calculated without any immobilization. Next, the measurements were repeated with the SAC, LAC, SSTS and DSTS. Each measurement was compared to the baseline value, and the percentage of rotation restriction was calculated. RESULTS: The most superior restriction rates were observed for the LAC (p = 0.00). No statistically significant difference was detected between the SSTS and DSTS in terms of the restriction of supination, pronation or the rotation arc (p values, 1.00, 0.18, and 0.50, respectively). Statistically significant differences were not detected between the SAC and the SSTS in any of the three parameters (p values, 0.25; 1.00; 1.00, respectively). When the SAC and DSTS were compared, while there was no significant difference between the two methods in pronation (p = 0.50), a statistically significant difference was detected in supination (p = 0.01) and in the total rotation arc (p = 0.03). CONCLUSION: The LAC provides superior results in restricting forearm rotation. The SAC and SSTS had similar effects on forearm rotation. The DSTS, which contains, in addition to the SSTS, a sugar tong portion above the elbow, does not provide additional rotational stability.


Assuntos
Antebraço , Imobilização , Contenções , Humanos , Masculino , Feminino , Adulto , Rotação , Antebraço/fisiologia , Adulto Jovem , Imobilização/métodos , Supinação/fisiologia , Pronação/fisiologia , Moldes Cirúrgicos , Voluntários Saudáveis , Amplitude de Movimento Articular/fisiologia
14.
Bone Joint J ; 106-B(6): 623-630, 2024 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-38821496

RESUMO

Aims: The aim of this trial was to assess the cost-effectiveness of a soft bandage and immediate discharge, compared with rigid immobilization, in children aged four to 15 years with a torus fracture of the distal radius. Methods: A within-trial economic evaluation was conducted from the UK NHS and personal social services (PSS) perspective, as well as a broader societal point of view. Health resources and quality of life (the youth version of the EuroQol five-dimension questionnaire (EQ-5D-Y)) data were collected, as part of the Forearm Recovery in Children Evaluation (FORCE) multicentre randomized controlled trial over a six-week period, using trial case report forms and patient-completed questionnaires. Costs and health gains (quality-adjusted life years (QALYs)) were estimated for the two trial treatment groups. Regression was used to estimate the probability of the new treatment being cost-effective at a range of 'willingness-to-pay' thresholds, which reflect a range of costs per QALY at which governments are typically prepared to reimburse for treatment. Results: The offer of a soft bandage significantly reduced cost per patient (saving £12.55 (95% confidence interval (CI) -£5.30 to £19.80)) while QALYs were similar (QALY difference between groups: 0.0013 (95% CI -0.0004 to 0.003)). The high probability (95%) that offering a bandage is a cost-effective option was consistent when examining the data in a range of sensitivity analyses. Conclusion: In addition to the known clinical equivalence, this study found that the offer of a bandage reduced cost compared with rigid immobilization among children with a torus fracture of the distal radius. While the cost saving was small for each patient, the high frequency of these injuries indicates a significant saving across the healthcare system.


Assuntos
Análise Custo-Benefício , Alta do Paciente , Fraturas do Rádio , Humanos , Criança , Fraturas do Rádio/terapia , Fraturas do Rádio/economia , Adolescente , Feminino , Masculino , Pré-Escolar , Bandagens/economia , Anos de Vida Ajustados por Qualidade de Vida , Reino Unido , Imobilização/métodos , Fixação de Fratura/economia , Fixação de Fratura/métodos , Qualidade de Vida , Análise de Custo-Efetividade
15.
Radiography (Lond) ; 30(3): 840-842, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38574580

RESUMO

INTRODUCTION: Magnetic Resonance-guided Focused Ultrasound (MRgFUS) treatment for certain anatomy locations can be extremely challenging due to patient positioning and potential motion. This present study describes the treatment of a recurrent tenosynovial giant cell tumor of the plantar forefoot using the ExAblate 2100 system in combination with patient immobilization device. METHODS: Prior to the treatment, several patient immobilization devices were investigated. Vacuum cushions were selected and tested for safety and compatibility with the treatment task and the MR environment. RESULTS: During the treatment, one vacuum cushion immobilized the patient's right leg in knee flexion and allowed the bottom of the foot to be securely positioned on the treatment window. Another vacuum cushion supported the patient upper body extended outside the scanner bore. 19 sonications were successfully executed. The treatment was judged to be successful. No immediate complications were observed. CONCLUSIONS: MRgFUS treatment of a recurrent tenosynovial giant cell tumor of the right plantar forefoot was successful with the use of patient immobilization vacuum cushions. IMPLICATIONS FOR PRACTICE: The immobilization system could be utilized to aid future MRgFUS treatment of lesions in challenging anatomic locations. Various sizes of the vacuum cushions are available to potentially better accommodate other body parts and treatment configurations.


Assuntos
Tumor de Células Gigantes de Bainha Tendinosa , Imobilização , Recidiva Local de Neoplasia , Humanos , Tumor de Células Gigantes de Bainha Tendinosa/diagnóstico por imagem , Tumor de Células Gigantes de Bainha Tendinosa/cirurgia , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Imobilização/instrumentação , Imobilização/métodos , Imageamento por Ressonância Magnética/métodos , Recidiva Local de Neoplasia/diagnóstico por imagem
16.
Exp Physiol ; 109(7): 1145-1162, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38687158

RESUMO

Limb immobilization causes rapid declines in muscle strength and mass. Given the role of the nervous system in immobilization-induced weakness, targeted interventions may be able to preserve muscle strength, but not mass, and vice versa. The purpose of this study was to assess the effects of two distinct interventions during 1 week of knee joint immobilization on muscle strength (isometric and concentric isokinetic peak torque), mass (bioimpedance spectroscopy and ultrasonography), and neuromuscular function (transcranial magnetic stimulation and interpolated twitch technique). Thirty-nine healthy, college-aged adults (21 males, 18 females) were randomized into one of four groups: immobilization only (n = 9), immobilization + action observation/mental imagery (AOMI) (n = 10), immobilization + neuromuscular electrical stimulation (NMES) (n = 12), or control group (n = 8). The AOMI group performed daily video observation and mental imagery of knee extensions. The NMES group performed twice daily stimulation of the quadriceps femoris. Based on observed effect sizes, it appears that AOMI shows promise as a means of preserving voluntary strength, which may be modulated by neural adaptations. Strength increased from PRE to POST in the AOMI group, with +7.2% (Cohen's d = 1.018) increase in concentric isokinetic peak torque at 30°/s. However, NMES did not preserve muscle mass. Though preliminary, our findings highlight the specific nature of clinical interventions and suggest that muscle strength can be independently targeted during rehabilitation. This study was prospectively registered: ClinicalTrials.gov NCT05072652.


Assuntos
Articulação do Joelho , Força Muscular , Humanos , Masculino , Feminino , Adulto Jovem , Força Muscular/fisiologia , Articulação do Joelho/fisiologia , Adulto , Imobilização/métodos , Estimulação Elétrica/métodos , Torque , Músculo Esquelético/fisiologia , Músculo Quadríceps/fisiologia , Imaginação/fisiologia , Joelho/fisiologia , Estimulação Magnética Transcraniana/métodos
17.
Handchir Mikrochir Plast Chir ; 56(3): 242-247, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38604235

RESUMO

BACKGROUND: Salter-Harris I and II fractures of the distal radius are common injuries. In our facility, immobilisation is performed in a way that counteracts angulation forces. The aim of our study was to determine whether there are significant differences between patients with and patients without a loss of reduction treated with this method and to determine what degree of flexion reliably prevents secondary displacement. PATIENTS AND METHODS: We conducted a retrospective study of 112 patients (mean age: 12 years) who had sustained a Salter-Harris type I or II fracture of the distal radius and were treated with reduction. Patients were grouped according to fracture type and whether they sustained a loss of reduction or not. Patients were compared for gender, age, initial angulation, angulation after reduction, degree of flexion/extension of the wrist in the cast, residual angulation, duration of immobilisation, and complication rate. We also analysed whether a 45-degree flexed position of the wrist in plaster provides reliable protection against secondary displacement. RESULTS: In group I, patients with no loss of reduction had a significantly greater degree of wrist flexion in the cast, a significantly shorter duration of immobilisation and significantly less residual angulation. Patients with an apex-volar deformity with the wrist immobilised at more than 45 degrees of flexion had no loss of reduction at all and had significantly less residual angulation compared with patients with the wrist immobilised at less than 45 degrees of flexion. In this patient group, loss of reduction was noted in 28% of cases. The patients in group II with loss of reduction showed a significantly higher angulation after the reduction. During the follow-up examination, one patient experienced physeal arrest followed by an ulnar impaction syndrome. Other complications recorded were minor. CONCLUSIONS: In summary, based on our results, we recommend that all physeal fractures of the distal radius with an apex-volar angulation can be safely treated with reduction and immobilisation counteracting the forces of angulation. For apex-dorsal fractures, palmar flexion of 45° allows for reliable reduction.


Assuntos
Moldes Cirúrgicos , Fraturas do Rádio , Humanos , Masculino , Feminino , Criança , Estudos Retrospectivos , Fraturas do Rádio/cirurgia , Fraturas do Rádio/fisiopatologia , Adolescente , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia , Traumatismos do Punho/cirurgia , Traumatismos do Punho/fisiopatologia , Amplitude de Movimento Articular/fisiologia , Fraturas Salter-Harris , Consolidação da Fratura/fisiologia , Seguimentos , Imobilização , Fraturas do Punho
18.
PLoS One ; 19(4): e0302127, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38662734

RESUMO

OBJECTIVES: To assess whether different cervical spine immobilisation strategies (full immobilisation, movement minimisation or no immobilisation), impact neurological and/or other outcomes for patients with suspected cervical spinal injury in the pre-hospital and emergency department setting. DESIGN: Systematic review following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. DATA SOURCES: MEDLINE, EMBASE, CINAHL, Cochrane Library and two research registers were searched until September 2023. ELIGIBILITY CRITERIA: All comparative studies (prospective or retrospective) that examined the potential benefits and/or harms of immobilisation practices during pre-hospital and emergency care of patients with a potential cervical spine injury (pre-imaging) following blunt trauma. DATA EXTRACTION AND SYNTHESIS: Two authors independently selected and extracted data. Risk of bias was appraised using the Cochrane ROBINS-I tool for non-randomised studies. Data were synthesised without meta-analysis. RESULTS: Six observational studies met the inclusion criteria. The methodological quality was variable, with most studies having serious or critical risk of bias. The effect of cervical spine immobilisation practices such as full immobilisation or movement minimisation during pre-hospital and emergency care did not show clear evidence of benefit for the prevention of neurological deterioration, spinal injuries and death compared with no immobilisation. However, increased pain, discomfort and anatomical complications were associated with collar application during immobilisation. CONCLUSIONS: Despite the limited evidence, weak designs and limited generalisability, the available data suggest that pre-hospital cervical spine immobilisation (full immobilisation or movement minimisation) was of uncertain value due to the lack of demonstrable benefit and may lead to potential complications and adverse outcomes. High-quality randomised comparative studies are required to address this important question. TRIAL REGISTRATION: PROSPERO REGISTRATION Fiona Lecky, Abdullah Pandor, Munira Essat, Anthea Sutton, Carl Marincowitz, Gordon Fuller, Stuart Reid, Jason Smith. A systematic review of cervical spine immobilisation following blunt trauma in pre-hospital and emergency care. PROSPERO 2022 CRD42022349600 Available from: https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42022349600.


Assuntos
Vértebras Cervicais , Serviços Médicos de Emergência , Imobilização , Traumatismos da Coluna Vertebral , Ferimentos não Penetrantes , Humanos , Vértebras Cervicais/lesões , Ferimentos não Penetrantes/terapia , Traumatismos da Coluna Vertebral/terapia , Serviço Hospitalar de Emergência
20.
Med Phys ; 51(6): 3822-3849, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38648857

RESUMO

Use of magnetic resonance (MR) imaging in radiation therapy has increased substantially in recent years as more radiotherapy centers are having MR simulators installed, requesting more time on clinical diagnostic MR systems, or even treating with combination MR linear accelerator (MR-linac) systems. With this increased use, to ensure the most accurate integration of images into radiotherapy (RT), RT immobilization devices and accessories must be able to be used safely in the MR environment and produce minimal perturbations. The determination of the safety profile and considerations often falls to the medical physicist or other support staff members who at a minimum should be a Level 2 personnel as per the ACR. The purpose of this guidance document will be to help guide the user in making determinations on MR Safety labeling (i.e., MR Safe, Conditional, or Unsafe) including standard testing, and verification of image quality, when using RT immobilization devices and accessories in an MR environment.


Assuntos
Imobilização , Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/instrumentação , Humanos , Imobilização/instrumentação , Radioterapia Guiada por Imagem/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA